W W W . C T S - T A N K . C O M ® INTERNAL FLOATING ROOFS Besides the most common pontoon type of internal floating roof CTS also offers a direct contact roof, which reduces emissions of volatile organic hydrocarbons (VOC’s) even more. The emission reduction after installing a direct contact internal floating roof is well in excess of 98%, if equipped with an effective seal. The CTS direct contact roofs are manufactured from aluminium panels, incorporating a light weight but strong honeycomb aluminium stiffening structure. The individual panels are fully welded and pressure tested prior to shipment, so the integrity of the panels is always guaranteed. On the jobsite the panels are positioned into the tank and easily assembled using a state-of-the-art hook and pin design to interconnect the elements. Apart from being very effective a direct contact roof is also low in height, maximising storage capacity for the tank involved. Direct contact internal floating roof, typical features: - emission reduction of VOC’s exceeding 98% - maintenance free - compatible with all stored products, including 100% aromatics - light weight structure manufactured from aluminium - can be fitted on tanks with diameters between 4 and 120 meters - expected service life excess of 30 years - designed for each specific tank - easy installation, full installation manuals and project support available - complies with API 650 Appendix H standard - successfully used globally by many major oil and tank storage companies - realistic engineering option for new storage tanks - suitable for high filling and emptying rates as well as Nitrogen pigging and mixing operations - can be equipped with several different seal designs in an extensive range of materials - suitable for 100% aromatics INTERNAL FLOATING ROOFS FOR STORAGE TANKS, DIRECT CONTACT TYPE Tel.: +31 (0)180 - 531027 Fax: +31 (0)180 - 531848 Website: www.cts-tank.com SYSTEMS AND PRODUCTS FOR INDUSTRIAL CARGO TRANSFER AND STORAGE

Transcript of Internal floating roofs dir Eng

Page 1: Internal floating roofs dir Eng

W W W . C T S - T A N K . C O M

®

INTE

RN

AL

FLO

ATI

NG

RO

OFS

Besides the most common pontoontype of internal floating roof CTSalso offers a direct contact roof,which reduces emissions of volatileorganic hydrocarbons (VOC’s) evenmore. The emission reduction afterinstalling a direct contact internalfloating roof is well in excess of98%, if equipped with an effectiveseal. The CTS direct contact roofsare manufactured from aluminiumpanels, incorporating a light weightbut strong honeycomb aluminium stiffening structure. The individualpanels are fully welded and pressuretested prior to shipment, so the integrity of the panels is alwaysguaranteed. On the jobsite thepanels are positioned into the tankand easily assembled using a state-of-the-art hook and pin designto interconnect the elements. Apartfrom being very effective a directcontact roof is also low in height,maximising storage capacity for thetank involved.

Direct contact internal floating roof, typical features:- emission reduction of VOC’s exceeding 98% - maintenance free- compatible with all stored products, including 100% aromatics- light weight structure manufactured from aluminium- can be fitted on tanks with diameters between 4 and 120 meters- expected service life excess of 30 years- designed for each specific tank- easy installation, full installation manuals and project support

available- complies with API 650 Appendix H standard- successfully used globally by many major oil and tank storage

companies- realistic engineering option for new storage tanks- suitable for high filling and emptying rates as well as Nitrogen

pigging and mixing operations- can be equipped with several different seal designs in an

extensive range of materials - suitable for 100% aromatics

INTERNAL FLOATING ROOFS FOR STORAGE TANKS, DIRECT CONTACT TYPE

Tel.: +31 (0)180 - 531027Fax: +31 (0)180 - 531848 Website: www.cts-tank.com

S Y S T E M S A N D P R O D U C T S F O R I N D U S T R I A L C A R G O T R A N S F E R A N D S T O R A G E

Internal floating roofs dir Eng 15-09-2004 10:26 Pagina 1

Page 2: Internal floating roofs dir Eng

Your distributor:

Seal arrangements:There are several different seal arrangementsavailable for internal floating roofs. Each seal hasits own specific areas of service. Seal materials willhave to be reviewed depending on the stored product. The most common seal arrangementsare:- single wiper seal- double wiper seal- mechanical shoe seal- foam sealLet our team of specialists recommend you thepreferred seal for your application.

Engineering aspects:Each roof will be designed for the tank it has to befitted in. CTS has developed forms with all relevantengineering information. This includes amongstothers the tank diameter, stored product, cleaningroutines, pumping rates and pigging requirements.The direct contact roof normally requires a doorsheet. It is, however, possible to produce elementsfitting through a 24" manhole if required.

The roof modules, the vital part:Essential for the performance of the roof is thequality of the supplied modules. In this respect it isgood to know that all modules are pressure testedprior to shipment. Each module is equipped with atesting plug and the internal honeycomb structureis perforated, facilitating testing of the completemodule. The basic design of the roof exceeds the floatation requirements of API by 350%, wherethe metallic skin exceeds API requirements forminimum thickness by more than 180%. This isthe best way to ensure the all important integrityof the roof.

Detailed product information:Obviously this leaflet could not address all details of our internal floating roofs. Full engineering information including material specifications, engineering drawings and otherrelevant information is available upon request, please feel free to ask for your copy.

Patented shoe plate seal, bottom view.

Offices: Trondheim 5 2993 LE Barendrecht The Netherlands

W W W . C T S - T A N K . C O M

®

Tel.: +31 (0)180 - 531027Fax: +31 (0)180 - 531848 E-mail: [email protected] Website: www.cts-tank.com

Replacing corroded external roofs:Besides being used in fixed roof tanks an internal floating roof is an excellent alternative for replacingheavily corroded external floating roofs. When combined with an aluminium dome roof it will eliminate rain water ingress, draining provisions,extensive repairs, blasting and painting. The combination of a dome and internal floating roofresults in very low emissions. This means that thegains go well beyond reducing just maintenancecosts.

All our product information and specifications are drafted with extreme care but can be subject to change. We do reserve the right to change product specifications.