InterActive™ System Catalog
Table of Contents
Page #
Surgical Drills, Sequence & Tray18-21
Implant Design & Surface 1
2-3 Implant Dimensions 2
10-11Selection Chart 6-7
Healing Collars, Transfers & Analogs
8
13Straight Abutment & Ancillary Components
9
Procedures for Contoured Abutments
10
15-16Straight & Angled Contoured,Titanium & Zirconia Abutments
11-12
Lab, Engaging & Non-Engaging Abutments13
18-19Selection Chart for Overdenture& Screw-Retained Restorations 14-15
Overdenture & Screw-ReceivingAbutment Ancillary Products
16
21Surgical & Prosthetic Instruments
17
Fixture Mount & IQity Impression Technique™
3
InterActive Implants4-5
The InterActive™ implant body features a straight top 1/3rd with micro-grooves to improve soft tissue attachment and micro-threads to increase stability and reduce stress in the crestal bone area. The quadruple-lead micro-threads transition to double-lead buttress threads over the bottom 2/3rds which is tapered to facilitate insertion into an undersized socket in soft bone providing compression that increases initial stability (G. Niznick: Clinical Oral Health 2000 “ Achieving Success in Soft Bone”). The slight body taper of the apical 1/3rd further facilitates self-tapping insertion into dense bone without over-compression.
InterActive features an internal hex conical connection with a 12° bevel for compatibility with InterActive as well as Nobel Biocare’s conical connection prosthetics. InterActive prosthetics and healing components are designed with matched transgingival concave emergence profiles to shape soft tissue for improved esthetics.
Simply Smarter Implant Design
Implant Design & Surface
SBM™ and SBActive™ Surface OptionsSBM surface is created by using a Soluble Blast Media of Hydroxylapatite (HA) crystals to create a medium-rough texture. We use the same vendor for its SBM and HA coated surface treatments as used by Paragon Implant Company from 1992-2000 when these studies were conducted. SBActive is a surface that has been prepared using a SBM process and then lightly coated with a layer of highly crystalline Hydroxylapatite. This results in a discontinuous surface with a medium rough texture.
Animal Studies Bone Response to SBM Surface
SBActive Surface 250XSBM Surface 250X
1
SEM’s of Our SurfacesSBM: Blasted with Soluble HA Particles
SBActive: 10µm layer of HA Particles
Buttress Thread
Double Lead Threads
Quadruple Lead Micro-
Threads
4.0 Deg.ID Taper
2 Deg.OD Taper
Coronal Micro-grooves
0.45mm
0.85mm
Brazilian Study* Shows SBM Provides Superior Bone Contact
Mean Percentage of Bone Contact%
80
70
60
50
40
30
20
10
SBM HA TPS Machined
62.7558.89
48.9141.70
LSU Study* Shows SBMProvides Superior Bone Contact%
80
70
60
50
40
30
20
10
SBM HA TPS Machined
63.8
57.6 52.7
36
*Data on file
0.25mmL Supra-Crestal 0.25mmL Supra-Crestal
0.25mmL Supra-Crestal
InterActive Implant Dimensions
3.2mmD InterActive2.6mmD Apex Diameter
Double-lead Buttress Threads
M1.6 Internal Thread
1.4mmL Zone Micro-grooves
Length + 0.25mm
SBM Texture
SBActive
3.7mmD InterActive3.0mmD Apex Diameter
Double-lead Buttress Threads
M1.6 Internal Thread
2.3mmL Zone Micro-threads
Length + 0.25mm
SBM Texture
SBActive
Taper starts at 1.5mm
Taper starts at 1.25mm
4.3mmD InterActive3.4mmD Apex Diameter
Double-lead Buttress Threads
M2 Internal Thread
2.3mmL Zone Micro-threads
Length + 0.25mm
SBActive
5.0mmD InterActive3.8mmD Apex Diameter
Taper starts at 0.76 mm
Taper starts at 0.76mm
SBM Texture
SBM Texture
Length + 0.25mm
2.3mmL Zone Micro-threads
M2 Internal Thread
SBActive
Double-lead Buttress Threads
2
2.3mmL Zone Micro-threads
1.4mmL Zone Micro-grooves
1.4mmL Zone Micro-grooves
1.4mmL Zone Micro-grooves
3.2mmD Body
1.5mm Hex Depth
0.25mmL Supra-Crestal
3.7mmD Body
3.0mmD Platform with
a 2.3mmD Internal Hex
4.3mmD Body1.5mm
Hex Depth
5.0mmD Body
3.4mmD Platform with
a 2.7mmD Internal Hex
InterActive Fixture-Mount & IQity Impression Technique™
Vial labels are color-coded with two tear-off labels
Each implant is packaged in a sterile vial
Fixture-mount top fails at 90Ncm(3.0mm platform) or 126Ncm (3.4mm)
Index fixture-mount flat to labial or buccal
Apply tissue replication material and pour stone model.
Shorten fixture-mount at the groove to create an abutment.
For longer abutment, block out groove with soft wax & lubricate
Fabricate restoration following standard techniques
Attach fixture-mount to implant analog (abutment analog also available)
Insert assembly into impression with fixture-mount top.
Attach cover screw and extender for one-stage surgery
Suture tissue. Extender will shape to match abutment profile
Place implant into osteotomy
Drop implant assembly out of vial onto a sterile surface
Cap labels are color-coded by platform diameter
Remove implant assembly with a ratchet or hex tool (HT2.3 or HT 2.7)
Hex will then be aligned for proper abutment placement
The top of the fixture-mount will be retained within the impression
Occlude fixture-mount scew access hole & take an impression
Loosen screw to remove the remaining abutment
3
InterActive Implant is mounted on a revolutionary two-piece color-coded fixture-mount. The top fails at excessive torques to protect the interface during insertion and detaches in impression for the accuracy of an open-tray transfer with the simplicity of a closed-tray. The fixture-mount may be shortened at the line to function as a final preparable abutment. A healing collar is included in each vial.
Extender
InterActive Implant System Features & Benefits
4.3mmD Implant
3.2mmD Implant
3.7mmD Implant
InterActive Packaging
3.0mmD Platform
3.0mmD Platform
3.4mmD Platform
3.4mmDPlatform65431313mmLTri-Grip
5.0mmD Implant
Fixture-Mount Transfer
Cover Screw
3.4mmD Platform
4
InterActive
Insertion & IQity Impression Technique™
Align flat to labial for indexing of internal hex
Use fixture-mount as closed tray transfer
Color-coded revolutionary2-piece fixture-mount
(Requires 2.3/2.7 tools or ratchet or FMD for insertion)
Square top detaches with impression material
• Internal conical connection compatible with NobelActive® and NobelReplace® CC abutments• Revolutionary two-piece fixture-mount. Top includes torque-safety feature and detaches in impression for the accuracy of an open-tray transfer with the simplicity of a closed-tray. This technique supports both implant-level and abutment-level impressions. • 2mm extender retained by cover screw for use as a platform-shifting healing collar for one-stage surgery features a concave transgingival profile which matches the fixture-mount. • Micro-grooves to improve soft tissue attachment• Micro-threads to increase stability and reduce stress in crestal bone area• Three long cutting grooves for self-tapping insertion extend 2/3rds length up the implant• Surface options: SBM (Soluble Blast Media) textured or SBActive™ light HA coating
3.2mmD
Replacement Surgical Cover Screws
InterActive: Two-Piece Implant
InterActive
SBM Code SBActive Code Diameter Length Platform653208 663208 3.2mmD 8mmL 3.0mmD653210 663210 3.2mmD 10mmL 3.0mmD653211 663211 3.2mmD 11.5mmL 3.0mmD653213 663213 3.2mmD 13mmL 3.0mmD653216 663216 3.2mmD 16mmL 3.0mmD
653210 663210
653213 663213
653216 663216
653208 663208
653211 663211
SBM Code SBActive Code Diameter Length Platform653706 663706 3.7mmD 6mmL 3.0mmD653708 663708 3.7mmD 8mmL 3.0mmD653710 663710 3.7mmD 10mmL 3.0mmD653711 663711 3.7mmD 11.5mmL 3.0mmD653713 663713 3.7mmD 13mmL 3.0mmD653716 663716 3.7mmD 16mmL 3.0mmD
3.7mmD
653710 663710
653713663713
653716 663716
653706 663706
653708 663708
653711 663711
4.3mmD
SBM Code SBActive Code Diameter Length Platform654306 664306 4.3mmD 6mmL 3.4mmD654308 664308 4.3mmD 8mmL 3.4mmD654310 664310 4.3mmD 10mmL 3.4mmD654311 664311 4.3mmD 11.5mmL 3.4mmD654313 664313 4.3mmD 13mmL 3.4mmD654316 664316 4.3mmD 16mmL 3.4mmD
654310 664310
654313664313
654316 664316
654306 664306
654308 664308
654311 664311
SBM Code SBActive Code Diameter Length Platform655006 665006 5.0mmD 6mmL 3.4mmD655008 665008 5.0mmD 8mmL 3.4mmD655010 665010 5.0mmD 10mmL 3.4mmD655011 665011 5.0mmD 11.5mmL 3.4mmD655013 665013 5.0mmD 13mmL 3.4mmD655016 665016 5.0mmD 16mmL 3.4mmD
5.0mmD
655010 665010
655013665013
655016 665016
655006 665006
655008 665008
655011 665011
SBM and SBActive Surface
Code [*for 6mmL Only] Platform6530-01 3.0mmD
*6530-01S 3.0mmD6534-01 3.4mmD
*6534-01S 3.4mmD6534-01*6530-01S
Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or Straumann SCS Driver
*6534-01S6530-01
5
Includes Fixture Mount with Tri-Grip™ Fixation Screw, Extender and Cover Screw. Extender NOT supplied with 6mmL implant
†non-engaging*6530-01S and 6534-01S for 6mmL implants only
6530-21 6530-22 6530-23
6530-47
Carrier/Transfer
6530-626530-62-15S 6530-63-30S
6530-92-15S 6530-93-15S 6530-93-30S 6530-94-30S
6530-63-15S 6530-64-30S
6530-01*
6530-08 65306530-05
6530-06
6530-31 6530-32 6530-336530-30L6530-51 6530-52 6530-53
6530-12 6530-13 6530-15
6530-21N 6530-22N 6530-23N
Narrow Carrier/Transfer
6530-08N 6530N6530-05N
6530-33N6530-31N 6530-51N 6530-32N 6530-52N 6530-53N
6530-12N 6530-13N 6530-15N
6530-40N 6530-47N
3.0mmD Platform
6530-91N 6530-92N
Transfers & Abutment Analogs
Healing Collars
Cover Screw & Implant Analog
Engaging & Non-Engaging Abutments
GPS™ & Screw-Receiving Overdenture AbutmentsBall Abutments Coming Soon
Straight Abutments
Straight & Angled Contoured & Lab Abutments
6
Selection Chart
6530-40†6530-41
†6530-49†6530-466530-44
6530-61
6530-31C6530-32C
6534-51-08C6534-51-15C6534-52-08C6534-52-15C
6530-63
6530-64 6530-65
6530-93N6530-94N 6530-95N 6530-96N
6534-21N 6534-22N 6534-23N
Narrow Carrier/Transfer
6534-08N
6534-12N
6534-05N
6534-31N 6534-51N 6534-32N 6534-52N 6534-33N 6534-53N
6534-13N 6534-15N
6534-47N
6534-21 6534-22 6534-23 6534-21W 6534-23W
6534-40N †6534-496534-47
Carrier/Transfer
7
3.4mmD Platform
6534-61N 6534-62N
6534-08W
6534-12
6534-05W6534-086534-05
6534-31 6534-51 6534-32 6534-52 6534-33 6534-53
6534-13 6534-15 6534-12W 6534-15W
6534-91N 6534-92N
65346534N
6534-22W
6534-13W
6534-31CN6534-32CN
6534-30LW
6534-066534-01*
6534-31CW 6534-32CW
6534-51-08CW 6534-51-15CW 6534-52-08CW 6534-52-15CW
6534-40†6534-41
6534-44†6534-46
6534-63N
6534-64N 6534-65N
6534-62-15S6534-63-15S
6534-63-30S6534-64-30S
6534-93N6534-94N
6534-95N6534-96N
6534-92-15S6534-93-15S
6534-93-30S6534-94-30S
8
Code Platform Replacement Screw - 2ea6530-05N 3.0mmD 1000-366530-05 3.0mmD 1000-36
6534-05N 3.4mmD 1000-336534-05 3.4mmD 1000-33
6534-05W 3.4mmD 1000-33
Closed-Tray Implant Transfers
Healing Collars, Transfers & Analogs
Code Platform6530-06 3.0mmD6534-06 3.4mmD
Implant Analogs
Code Width Length Platform6530-12 5.0mmD 2mmL 3.0mmD6530-13 5.0mmD 3mmL 3.0mmD6530-15 5.0mmD 5mmL 3.0mmD6534-12 5.8mmD 2mmL 3.4mmD6534-13 5.8mmD 3mmL 3.4mmD6534-15 5.8mmD 5mmL 3.4mmD
Narrow Healing Collars
Code Width Length Platform6530-12N 3.8mmD 2mmL 3.0mmD6530-13N 3.8mmD 3mmL 3.0mmD6530-15N 3.8mmD 5mmL 3.0mmD6534-12N 5.0mmD 2mmL 3.4mmD6534-13N 5.0mmD 3mmL 3.4mmD6534-15N 5.0mmD 5mmL 3.4mmD
6530-05N1000-36 1000-33 6530-05 6534-05N 6534-05 6534-05W
Code Platform Replacement Screw - 2ea6530-08N 3.0mmD 1000-376530-08 3.0mmD 1000-37
6534-08N 3.4mmD 1000-356534-08 3.4mmD 1000-35
6534-08W 3.4mmD 1000-35
Open-Tray Implant Transfers
6530-06 6534-06
Includes Tri-Grip™ Fixation Screw
6530-12N
6534-12N
6530-13N
6534-13N
6534-15N
6534-15N
Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or Straumann SCS Driver
Code Width Length Platform6534-12W 6.6mmD 2mmL 3.4mmD6534-13W 6.6mmD 3mmL 3.4mmD6534-15W 6.6mmD 5mmL 3.4mmD
Wide Healing Collars
6534-12W 6534-13W 6534-15W
Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or Straumann SCS Driver
6530-08N 6530-08 6534-086534-08N 6534-08W
Includes Tri-Grip™ Fixation Screw
Healing Collars
6530-12 6530-13 6530-15
6534-12 6534-13 6534-15
Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or Straumann SCS Driver
1000-351000-37
Straight Abutment Castable Copings
Straight Abutments Kits
Code Platform Abutment Width Collar Heights Replacement Screw6530-21N 3.0mmD 3.7mmD 1mm 1000-346530-22N 3.0mmD 3.7mmD 2mm 1000-346530-23N 3.0mmD 3.7mmD 3mm 1000-346530-21 3.0mmD 4.7mmD 1mm 1000-346530-22 3.0mmD 4.7mmD 2mm 1000-346530-23 3.0mmD 4.7mmD 3mm 1000-34
6534-21N 3.4mmD 4.7mmD 1mm 1000-326534-22N 3.4mmD 4.7mmD 2mm 1000-326534-23N 3.4mmD 4.7mmD 3mm 1000-326534-21 3.4mmD 5.7mmD 1mm 1000-326534-22 3.4mmD 5.7mmD 2mm 1000-326534-23 3.4mmD 5.7mmD 3mm 1000-32
6534-21W 3.4mmD 6.5mmD 1mm 1000-326534-22W 3.4mmD 6.5mmD 2mm 1000-326534-23W 3.4mmD 6.5mmD 3mm 1000-32
Straight Abutments, Snap-on Transfers & Lab Analogs
Code Abutment Width3037-26 3.7mmD3047-26 4.7mmD3057-26 5.7mmD3065-26 6.5mmD
Code Abutment Width3037-02 3.7mmD3047-02 4.7mmD3057-02 5.7mmD3065-02 6.5mmD
Straight Abutment Transfers
Straight Abutment Comfort Caps
3037-02
Code Abutment Width3037-28 3.7mmD3047-28 4.7mmD3057-28 5.7mmD3065-28 6.5mmD
3047-28 3057-28 3065-283037-28
3047-02 3057-02 3065-02
3047-26 3057-26 3065-263037-26
6530-21N
Includes Straight Abutment Transfer, Analog, Castable Coping, Comfort Cap & Fixation Screw with Tri-Grip™
6534-23W6534-22W6534-21W
6530-21 6530-22 6530-23
6534-22 6534-236534-21
9
Straight Abutment Analogs
Code Abutment Width3037 3.7mmD3047 4.7mmD3057 5.7mmD3065 6.5mmD
Includes Castable Coping
3037 306530573047
6534-23N6534-22N6534-21N
6530-22N 6530-23N
Option 2: Stage-One transfer followed by laboratory procedures for abutment preparation and provisionalization
During implant placement, index the flat of the Fixture-Mount
Pour the working cast in dental stone with soft tissue replication material
Apply impression material and proceed with IQity™ Impression Technique
Attach the Cover Screw and submerge implant
Attach bottom portion of Fixture-Mount to Implant Analog and snap into the top within the impression
Remove the Fixture-Mount from the working cast with the 1.25mmD Hex Tool
Attach the Angled Abutment to the Implant Analog in the working cast with a 1.25mmD Hex Tool
Modify angle of abutment and refine margins as required
Fabricate the temporary crown
Occlude screw access hole and confirm contour of restoration
Cement theprovisional restoration
At Stage-2 surgery, attach the preparedabutment and tighten to 30Ncm with a Torque Wrench
To establish the optimum angle of the abutment, index the flat surface of the Fixture Mount/Transfer either toward or away from the desired direction of abutment angle at the time of implant placement.
Orienting the 15º Angled AbutmentThe flat side of the Fixture Mount/Transfer [Fig. 1] and the angle of the 15°
abutment [Fig. 2] are manufactured to align with the flat of the implant’s hex.
Option 1: Attaching an Angled Abutment and chairside procedures for preparation
Common procedures for abutment placement, margin finessing, impressing and placement of restoration
Remove the Healing Collar with a 1.25mmDHex Tool
Attach provisional restoration and cement onto theprepared abutment
Attach the abutment with the 1.25mmD Hex Tool
Tighten to 30Ncm with a Torque Wrench
Make an impression following standardclinicalprocedures
Mark the requiredmodifications to achieveappropriate clearance
Finesse themargins with a high-speed bur and copious irrigation prior to final impressing
Attach the abutment to the corresponding Implant Analog. Reduce the abutmentto achieve appropriate clearance
Following standard laboratory procedures, fabricate the final restoration and cement onto the prepared abutment
Fig. 2 The two-piece, 15º Angled Abutment consists of an angled
body and a fixation screw Fig. 1Fixture Mount/Transfer
Detach the abutment with the 1.25mmD Hex Tool
Clinical & Laboratory Procedures for Contoured Abutments
10
Straight Titanium Contoured Abutments
15º Angled Titanium Contoured Abutments
Code Platform Collar Heights Replacement Screw6530-31N 3.0mmD 1mm 1000-346530-32N 3.0mmD 2mm 1000-346530-33N 3.0mmD 3mm 1000-346530-31 3.0mmD 1mm 1000-346530-32 3.0mmD 2mm 1000-346530-33 3.0mmD 3mm 1000-34
6534-31N 3.4mmD 1mm 1000-326534-32N 3.4mmD 2mm 1000-326534-33N 3.4mmD 3mm 1000-326534-31 3.4mmD 1mm 1000-326534-32 3.4mmD 2mm 1000-326534-33 3.4mmD 3mm 1000-32
Includes Tri-Grip™ Fixation Screw
Fixture-Mounts, Analogs, Straight & Angled Contoured Titanium Abutments
6530-31N 6530-32N 6530-33N
6534-32N 6534-33N
Code Platform Collar Heights Replacement Screw6530-51N 3.0mmD 1mm 1000-346530-52N 3.0mmD 2mm 1000-346530-53N 3.0mmD 3mm 1000-346530-51 3.0mmD 1mm 1000-346530-52 3.0mmD 2mm 1000-346530-53 3.0mmD 3mm 1000-34
6534-51N 3.4mmD 1mm 1000-326534-52N 3.4mmD 2mm 1000-326534-53N 3.4mmD 3mm 1000-326534-51 3.4mmD 1mm 1000-326534-52 3.4mmD 2mm 1000-326534-53 3.4mmD 3mm 1000-32
6534-53
Includes Tri-Grip™ Fixation Screw
6530-536530-51 6530-52
6534-52
6530-51N 6530-52N 6530-53N
6534-51N 6534-52N 6534-53N
6534-51
6530-326530-31 6530-33
6534-326534-31 6534-33
Fixture-Mounts
Code Platform Collar Heights6530-02N 3.0mmD 2mm6530-02 3.0mmD 2mm
6534-02N 3.4mmD 2mm6534-02 3.4mmD 2mm
Fixture-Mount Analogs- Concave Profile
Code Platform Abutment Width6530N 3.0mmD 3.7mmD6530 3.0mmD 4.7mmD
6534N 3.4mmD 5.7mmD6534 3.4mmD 6.5mmD
6530N 65346534N6530
Includes Tri-Grip™ Fixation Screw
6530-02N 6534-02N6530-02 6534-02
6534-31N
11
0°, 8° & 15° Zirconia Contoured Abutments
Replacement Fixation Screws
Zirconia Abutments
Code Platform1000-34S1 3.0mmD1000-34 3.0mmD1000-36 3.0mmD1000-37 3.0mmD1000-54 3.0mmD
1000-32S1 3.4mmD1000-32 3.4mmD1000-33 3.4mmD1000-35 3.4mmD1000-52 3.4mmD
1000-361000-34
1000-521000-32
1000-34S1
1000-32S1
1000-54
Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or Straumann SCS Driver. Short (S) screws are Dual-Grip™
1000-35
1000-37
1000-33
Code Platform Angulation Collar Heights Replacement Screw6530-30CB 3.0mmD 0° .5mm 1000-346530-31C 3.0mmD 0° 1.5mm 1000-346530-32C 3.0mmD 0° 2.5mm 1000-34
6530-51-08C 3.0mmD 8° 1.5mm 1000-346530-52-08C 3.0mmD 8° 2.5mm 1000-346530-51-15C 3.0mmD 15° 1.5mm 1000-346530-52-15C 3.0mmD 15° 2.5mm 1000-34
Code Platform Angulation Collar Heights Replacement Screw6534-30CB 3.4mmD 0° .5mm 1000-32
6534-30CBW 3.4mmD 0° .5mm 1000-326534-31CN 3.4mmD 0° 1.5mm 1000-326534-31CW 3.4mmD 0° 1.5mm 1000-326534-32CN 3.4mmD 0° 2.5mm 1000-326534-32CW 3.4mmD 0° 2.5mm 1000-32
6534-51-08CN 3.4mmD 8° 1.5mm 1000-326534-52-08CN 3.4mmD 8° 2.5mm 1000-326534-51-15CN 3.4mmD 15° 1.5mm 1000-326534-52-15CN 3.4mmD 15° 2.5mm 1000-326534-51-08CW 3.4mmD 8° 1.5mm 1000-326534-52-08CW 3.4mmD 8° 2.5mm 1000-326534-51-15CW 3.4mmD 15° 1.5mm 1000-326534-52-15CW 3.4mmD 15° 2.5mm 1000-32
Price includes a Tri-Grip™ Fixation Screw
6530-52-08C 6530-52-15C
6530-51-15C
6534-51-08CN6534-31CN
6534-51-15CW6534-51-08CW
6534-30CB
6534-30CBW
6530-30CB
6530-31C
6530-32C
6534-51-15CN
6534-52-08CN 6534-52-15CN
6534-52-15CW
6534-32CN
6530-51-08C
6534-52-08CW
1Short (S) screws are Dual-Grip™ for use with for use with 1.25mmD Hex Tool or Nobel Unigrip ScrewDriver.12
6534-31CW
6534-32CW
1Short (S) screws are Dual-Grip™ for use with for use with 1.25mmD Hex Tool or Nobel Unigrip ScrewDriver.
Includes Tri-Grip™ Fixation Screw
Includes Tri-Grip™ Fixation ScrewTitanium Non-Engaging Temporary Abutments
Includes Tri-Grip™ Fixation ScrewPlastic Non-Engaging Castable Abutments
Lab, Engaging & Non-Engaging Abutments
Code Collar Heights Platform Replacement Screw6530-46 - 3.0mmD 1000-546534-46 - 3.4mmD 1000-52
Code Collar Heights Platform Replacement Screw6530-49 - 3.0mmD 1000-546534-49 - 3.4mmD 1000-52
Code Collar Heights Platform Replacement Screw6530-40N 1mm 3.0mmD 1000-346530-40 1mm 3.0mmD 1000-34
6534-40N 1mm 3.4mmD 1000-326534-40 1mm 3.4mmD 1000-32
Gold Engaging Cast-to Abutments
Code Collar Heights Platform Replacement Screw6530-41 1mm 3.0mmD 1000-546534-41 1mm 3.4mmD 1000-52
Includes Tri-Grip™ Fixation ScrewGold Non-Engaging Cast-to Abutments
Includes Tri-Grip™ Fixation ScrewPlastic Engaging Temporary Abutments
Code Collar Heights Platform Replacement Screw6530-47N - 3.0mmD 1000-366530-47 - 3.0mmD 1000-36
6534-47N - 3.4mmD 1000-336534-47 - 3.4mmD 1000-33
13
6530-47N 6530-47 6534-47N 6534-47
6530-40N 6530-40
6534-406534-40N
6530-41 6534-41
6530-46 6534-46
6530-49 6534-49
Includes Tri-Grip™ Fixation ScrewStraight Full Contour Abutments
Code Collar Heights Platform Replacement Screw6530-30L - 3.0mmD 1000-34
6534-30LW - 3.4mmD 1000-32 6530-30L 6534-30LW
Code Collar Heights Platform Replacement Screw6530-44 - 3.0mmD 1000-346534-44 - 3.4mmD 1000-32
Includes Tri-Grip™ Fixation ScrewPlastic Engaging Castable Abutments
6530-44 6534-44
*1000-68*4000-13 1000-61
Open-Tray Transfer
1000-62
Closed-Tray Transfer
1000-63
Gold Titanium Plastic Gold/Plastic Titanium
1000-64 1000-65 1000-66 1000-67 1000-69
14
Selection Chart: Overdenture & Screw-Retained Restorations
OverdentureAbutments
Overdenture Copings
OverdentureAbutment
Components
6534-62N6530-62-15S 6530-63-15S 6530-63-30S 6530-64-30S
Overdenture Abutments (*Includes Transfer and Comfort Cap)
Overdenture Abutment Transfers, Analog & Comfort Cap
GPS™Abutment
Components
GPS™ Abutments
GPS™ Abutments (***Includes Transfer, Abutment Housing Kit and Comfort Cap)
GPS® Attachments
6534-62-15S 6534-63-15S 6534-63-30S 6534-64-30S
OD Abutment Comfort Cap
Transfers and Analog
***1000-94
1000-92C
1000-95
1000-92E
1000-98S1000-93***4500-26
1000-92R1000-91
1000-92G
1000-92B1000-92P 1000-92W 1000-98SI 1000-96
6530-61 6530-646530-63 6530-656530-62 6534-65N6534-64N6534-63N6534-61N
6530-92-15S 6530-93-15S 6530-93-30S 6530-94-30S
6534-92-15S 6534-93-15S 6534-93-30S 6534-94-30S
6530-91N 6530-92N 6530-93N 6530-94N 6530-95N 6530-96N 6534-91N 6534-92N 6534-93N 6534-94N 6534-95N 6534-96N
***1000-91W
3.0mmD Platform 3.4mmD Platform
Screw-Receiving, GPS® Abutments & Angled Base Components (Ball Abutments Coming Soon)
Code Collar Heights Platform6530-61 1mm 3.0mmD6530-62 2mm 3.0mmD6530-63 3mm 3.0mmD6530-64 4mm 3.0mmD6530-65 5mm 3.0mmD
6534-61N 1mm 3.4mmD6534-62N 2mm 3.4mmD6534-63N 3mm 3.4mmD6534-64N 4mm 3.4mmD6534-65N 5mm 3.4mmD
Overdenture Abutments
Platform Collar Heights 15º Angled 30º Angled 3.0mmD 2.5mm 6530-62-15S3.0mmD 3.5mm 6530-63-15S 6530-63-30S3.0mmD 4.5mm 6530-64-30S3.4mmD 2.5mm 6534-62-15S3.4mmD 3.5mm 6534-63-15S 6534-63-30S3.4mmD 4.5mm 6534-64-30S
Angled Overdenture Abutments
Includes Transfer & Comfort Cap [1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or Straumann SCS Driver]
Includes Dual-Grip™ Abutment Screw, Transfer & Comfort Cap
15
6530-61
6534-61N
6530-64
6534-64N
6530-65
6534-65N
6530-62
6534-62N
6530-63
6534-63N
6530-63-15S6530-62-15S 6530-64-30S6530-63-30S
6534-63-15S6534-62-15S 6534-64-30S6534-63-30S
Platform Collar Heights 15º Angled 30º Angled 3.0mmD 2.5mm 6530-92-15S3.0mmD 3.5mm 6530-93-15S 6530-93-30S3.0mmD 4.5mm 6530-94-30S3.4mmD 2.5mm 6534-92-15S3.4mmD 3.5mm 6534-93-15S 6534-93-30S3.4mmD 4.5mm 6534-94-30S
Angled GPS Abutments
6530-94-30S6530-92-15S 6530-93-30S6530-93-15S
6534-94-30S6534-92-15S 6534-93-30S6534-93-15S
GPS Abutments
Code Collar Heights Platform6530-91N 1mm 3.0mmD6530-92N 2mm 3.0mmD6530-93N 3mm 3.0mmD6530-94N 4mm 3.0mmD6530-95N 5mm 3.0mmD6530-96N 6mm 3.0mmD6534-91N 1mm 3.4mmD6534-92N 2mm 3.4mmD6534-93N 3mm 3.4mmD6534-94N 4mm 3.4mmD6534-95N 5mm 3.4mmD6534-96N 6mm 3.4mmD
Code Description1000-70S Replacement Ball Top for Angled Base Short [Requires 1.25mmD Hex Tool]
1000-90S Replacement GPS Top for Angled Base Short [Requires GoDirect Implant Tool]
Replacement Tops for Angled Abutments Includes Transfer & Comfort Cap
1000-90S1000-70S
Includes Dual-Grip™ Abutment Screw, Transfer, Comfort Cap, GPS Abutment Housing Kit & White Male Liner [Top requires GoDirect Implant Tool]
Includes Transfer, Comfort Cap, GPS Abutment Housing Kit & White Male Liner [1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or Straumann SCS Driver]
6530-91N 6530-92N 6530-93N 6530-94N 6530-95N 6530-96N
6534-91N 6534-92N 6534-93N 6534-94N 6534-95N 6534-96N
Overdenture Abutment Comfort Cap, Transfers & Analog
Code Description1000-96 Core Tool - Male Removal & Seating Tool
GDIT GoDirect Implant Tool (Square connection for use with Ratchet or Torque Wrench)
Code Platform Description1000-61 5.0mmD Aluminum Analog1000-62 5.0mmD Open-Tray Transfer plus Fixation Screw1000-63 5.0mmD Closed-Tray Transfer plus Fixation Screw1000-68 5.0mmD Plastic Abutment Transfer - 2ea4000-13 5.0mmD Plastic Comfort Cap - 2ea1000-14 - Replacement Open-Tray Fixation Screw - 2ea1000-15 - Replacement Closed-Tray Fixation Screw - 2ea
Code Description 1000-94 Impression Coping - 2ea 1000-95 Abutment Analog 4mmD - 2ea 1000-97 Abutment Parallel Post - 4ea 4500-26 Comfort Cap - 2ea 1000-99 Plastic Abutment Angle Measure Guide
16
GPS Abutment Transfer, Analogs & Alignment Tools
Ancillary Components for Overdenture & Screw-Retained Restorations
Screws require 1.25mmD Hex Tool
1000-681000-61 1000-62 1000-63 4000-13
1000-97
1000-95
4500-26
1000-94
Code Retention Force Description 1000-92W 5.0lbs Internal Replacement Male White - 4ea 1000-92P 3.0lbs Internal Replacement Male Pink - 4ea 1000-92B 1.5lbs Internal Replacement Male Blue - 4ea 1000-92C 4.5lbs External Replacement Male Clear - 4ea 1000-92G 3.0lbs External Replacement Male Green - 4ea 1000-92E 2.0lbs External Replacement Male Orange - 4ea 1000-92R 1.0lb External Replacement Male Red - 4ea 1000-91 - GPS Abutment Housing Kit - 1ea 1000-91W - GPS Housing Kit w/ White Internal Male - 1ea 1000-93 - Black Processing Male - 4ea 1000-98SI Assorted Internal Processing Cap/Male Kit - 1ea 1000-98S Assorted External Processing Cap/Male Kit - 1ea
GPS Abutment Components
Overdenture Abutment Components
Code Platform Description1000-64 5.0mmD Gold Coping1000-65 5.0mmD Titanium Coping1000-66 5.0mmD Plastic Coping1000-67 5.0mmD Gold & Plastic Coping1000-69 5.0mmD Titanium Temporary Coping 1000-05 - Coping Fixation Screw - 2ea1000-25 - Dual-Grip™ Coping Fixation Screw - 2ea
1000-661000-65 1000-67
1000-05
1000-64 1000-691000-25
Includes Fixation Screw [1000-05], optional Dual-Grip™ Fixation Screw [1000-25]
1000-92B 1000-98SI
GPS Instrumentation
GDIT
1000-99
1000-93
1000-92E1000-92P
1000-92C
1000-98S
1000-92G1000-92W
1000-92R
1000-911000-91W
1000-96
Code DescriptionIST Empty Surgical Kit for InterActive Implants
IBST Basic Surgical Kit for InterActive ImplantsICST Surgical Kit for InterActive Implants
Code DescriptionHT1.25L 1.25mmD Straight Hex Tool Extra Long (For use with Torque Wrench)
HT1.25 1.25mmD Straight Hex Tool Long (For use with Torque Wrench)
HT1.25S 1.25mmD Straight Hex Tool Short (For use with Torque Wrench)
HT2.3 2.3mmD Straight Hex Tool Long (with retentive O-ring)
HT2.3S 2.3mmD Straight Hex Tool Short (with retentive O-ring)
HT2.7 2.7mmD Straight Hex Tool Long (with retentive O-ring)
HT2.7S 2.7mmD Straight Hex Tool Short (with retentive O-ring)
AXS3.0 3.0mmD Abutment Removal Screw (For use with Straight 1.25mmD Hex Tools)
AXS3.4 3.4mmD Abutment Removal Screw (For use with Straight 1.25mmD Hex Tools)
Surgical & Prosthetic Instruments
Tapered Hex Tools
Code DescriptionTHT1.25 1.25mmD Tapered Hex Tool-Long
THT1.25S 1.25mmD Tapered Hex Tool-ShortTHT1.25STHT1.25
Hex Drills
Code DescriptionHD1.25 1.25mmD Hex DrillHD2.3 2.3mmD Hex Drill (with retentive O-ring)HD2.7 2.7mmD Hex Drill (with retentive O-ring)
HD2.3 HD2.7
Latch head connection for use with Surgical Motor
Code DescriptionR Ratchet
TW30 30Ncm Torque WrenchTW35 35Ncm Torque Wrench
SSH2.5 2.5mmD Stainless Steel Handle (with retentive O-ring)
FMD Fixture Mount Drill (with retentive O-ring)
PAR Paralleling Tool 2.8/2.3LDRILL Locator Drill (2.3mmD)
DE Drill ExtenderTWM Multi-Setting Torque Wrench (15, 20, 25, 30, 35, 40, 45, 50 & 60Ncm)
ABH Analog Holder
Ancillary Instruments
TW30
PAR
R
FMD
ABHTWM
Surgical Trays
IST ICSTIBST
Straight Hex Tools
HT2.7HT2.3HT1.25
HT2.3S HT2.7SHT1.25S
Square connection for use with Ratchet or Torque Wrench
HT1.25L
LDRILL
TW35
DE
SSH2.5
17
HD1.25
AXS3.0
AXS3.4
18
Code DescriptionSD2.3 2.3/2.0mmD Step Drill with 6-16 markings
SD2.3S 2.3/2.0mmD Step Drill with 6-10 markingsSD2.8 2.8/2.3mmD Step Drill with 6-16 markings
SD2.8S 2.8/2.3mmD Step Drill with 6-10 markingsCBD3.2 Cortical Bone Drill for 3.2mmD Implants
3.2mmD Implants SD2.3 SD2.3S SD2.8 SD2.8S CBD3.2
Surgical Drills
Code DescriptionSD3.4 3.4/2.8mmD Step Drill with 6-16 markings
SD3.4S 3.4/2.8mmD Step Drill with 6-10 markingsCBD3.7 Cortical Bone Drill for 3.7mmD Implants
3.7mmD Implants SD3.4 SD3.4S CBD3.7
Code DescriptionSD3.8 3.8/3.4mmD Step Drill with 6-16 markings
SD3.8S 3.8/3.4mmD Step Drill with 6-10 markingsCBD4.2 Cortical Bone Drill for 4.3mmD Implants
4.3mmD Implants SD3.8 SD3.8S CBD4.2
Code DescriptionSD4.4 4.4/3.8mmD Step Drill with 6-16 markings
SD4.4S 4.4/3.8mmD Step Drill with 6-10 markingsCBD4.7 Cortical Bone Drill for 5.0mmD Implants
5.0mmD Implants SD4.4S CBD4.7SD4.4
19
Drill Sequence
3.2mmD Straight / Tapered Implant
3.7mmD Straight / Tapered Implant
4.3mmD Straight / Tapered Implant
3.0/3.7
3.4/4.3
3.0/3.2
CBD3.7 SD2.3 2.3/2.0mmD
SD3.4 3.4/2.8mmD
Dense Bone Final
SD2.8 2.8/2.3mmD
Soft Bone Final Optional Crestal Bone Drills*
CBD3.2 SD2.3 2.3/2.0mmD
SD2.8 2.8/2.3mmD
Dense Bone FinalSoft Bone Final Optional Crestal Bone Drills*
CBD4.2 SD2.8 2.8/2.3mmD
Optional
SD2.3 2.3/2.0mmD
SD3.8 3.8/3.4mmD
or length specific NobelReplace®
RP drill
Dense Bone Final
SD3.4 3.4/2.8mmD
or length specific NobelReplace®
RP drill
Soft Bone Final Optional Crestal Bone Drills*
5.0mmD Straight / Tapered Implant3.4/5.0
CBD4.7 SD3.4 3.4/2.8mmD
SD2.8 2.8/2.3mmD
Optional
SD2.3 2.3/2.0mmD
SD4.4 4.4/3.8mmD
or length specific NobelReplace®
WP drill
Dense Bone Final
SD3.8 3.8/3.4mmD
or length specific NobelReplace®
WP drill
Soft Bone Final Optional Crestal Bone Drills*
*To be used in very dense bone
20
PAR (4)
LDRILL DE
R
SSH2.5
InterActive Complete Surgical Tray Contents
THT1.25S HT1.25S
THT1.25 HT1.25
HD1.25 FMD
SD2.3 SD2.3S
Lower level of surgical tray
SD4.4 SD4.4S CBD4.7SD3.8 SD3.8S CBD4.2SD3.4 SD3.4S CBD3.7SD2.8 SD2.8S CBD3.2
HT2.7 HT2.7S HD2.7 HT2.3 HT2.3S HD2.3
21
InterActive Surgical Tray
Surgical Tray Contents Complete Kit Basic Kit Code DescriptionIST Empty Surgical Tray X X
SD2.3 2.3/2.0mmD Step Drill-Long X XSD2.3S 2.3/2.0mmD Step Drill-Short XSD2.8 2.8/2.3mmD Step Drill-Long X X
SD2.8S 2.8/2.3mmD Step Drill-Short XCBD3.2 3.2mmD Cortical Drill XSD3.4 3.4/2.8mmD Step Drill-Long X X
SD3.4S 3.4/2.8mmD Step Drill-Short XCBD3.7 3.7mmD Cortical Drill XSD3.8 3.8/3.4mmD Step Drill-Long X X
SD3.8S 3.8/3.4mmD Step Drill-Short XCBD4.2 4.2mmD Cortical Drill XSD4.4 4.4/3.8mmD Step Drill-Long X X
SD4.4S 4.4/3.8mmD Step Drill-Short XCBD4.7 4.7mmD Cortical Drill X
Hex ToolsTHT1.25 1.25mmD Tapered Hex Tool-Long X X
THT1.25S 1.25mmD Tapered Hex Tool-Short XHT1.25 1.25mmD Straight Hex Tool-Long X X
HT1.25S 1.25mmD Straight Hex Tool-Short XHT2.3 2.3mmD Hex Tool-Long X X
HT2.3S 2.3mmD Hex Tool-Short XHT2.7 2.7mmD Hex Tool-Long X X
HT2.7S 2.7mmD Hex Tool-Short XHD1.25 1.25mmD Hex Drill X XHD2.3 2.3mmD Hex Drill XHD2.7 2.7mmD Hex Drill X
Ancillary InstrumentationFMD Fixture Mount Drill X
LDRILL Locator Drill X XDE Drill Extender X XR Ratchet X X
PAR (x4) Paralleling Tool 2.8/2.3 X XSSH2.5 2.5mmD Stainless Steel Handle X
Lid Inside Empty Tray
*7.5-2-14-0073* 7.5K-2-14-0073i Printed in the U.S.A. Copyright © 2014 Implant Direct Sybron International. All Rights Reserved
www.implantdirect.com
Neck Matched to Major Diameter• Seals opening at crest of ridge reducing need for bone grafting
Micro-threads and Grooves • Micro-grooves to improve soft tissue attachment and micro-threads to increase stability and reduce stress in crestal bone area
Cutting Edge of Grooves Face Clockwise • Three long grooves for self-tapping insertion vs reverse cutting grooves for removing implant
Apical 1/3rd Tapers 2º • Slight body taper increases initial stability without over-compression and facilitates self-tapping insertion in dense bone
Rounded Apex • Reduces risk during insertion of implant diverging from path created by drilling and the risk of sinus perforation
All-in-1 PackagingIncludes implant, cover screw, healing collar & new fixture-mount that provides simply accurate impression taking as well as functions as a preparable abutment
InterActive™NobelActive™ Compatible Conical Connection
with Simply Smarter Surgical & Restorative Design
Matched Concave Transgingival Profile on Abutments & Components • Shape soft tissue for improved esthetics
Compatible Abutments with Longer Hex/Shorter Bevel• Reduce the need to confirm seating with X-rays
Two Color-coded Implant Platforms for Four Implant Diameters • Restore more implants with a smaller prosthetic inventory and easily identify the correct size
Simply Smarter Restorations
Simply Smarter Surgery
Measurements based upon 4.3mm diameter, 13mm length implants. Dimensions can vary.
IQity Impression Technique™Patent pending fixture-mount design provides:
• The ease of a closed-tray impression• The accuracy of an open-tray impression• The versatility to create impression at
either implant-level or abutment-level