INTD 59 intro to kitchen & bath design
bathroom electrical, lighting & Title 24
CODE: At least one wall-switch controlled light must be provided in the kitchen and bath. Switch must be placed at the entrance.
California residential lighting—title 24bathrooms—zone 2
• must have:• high efficacy fixtures• OR vacancy sensors installed that
control the low efficacy fixturesdimmer option
• vacancy sensors• allows user to manually turn on the
light upon entering the room• when vacancy detected, turns lights
off
electrical
when gathering project information on site, note location of the main electrical panel & its rated amperage capacity
CODE: Ground fault circuit interrupter (GFCI) outlet protection is required on all receptacles servicing countertop surfaces in the kitchen and bath
all power outlets in the bath can be controlled on one circuit interrupter—power can be easily reset using button on primary outlet
well-designed lighting of the utmost importance in bathrooms
typical mistake—recessed downlight over sink•harsh light hitting top of head•long dark shadows appear under eyes, nose & chin
typical mistake—one surface-mounted above mirror•illuminates top of face•bottom half falls into shadow•especially hard light by which to shave
task lighting at sink
use two luminaires flanking mirror
task lighting at sink
use two luminaires flanking mirror
task lighting at sink
task lighting at sink
task lighting at sink
task lighting at sink
task lighting at sink
use two luminaires flanking mirror
lighting for tubs and showers
need a good general light that is listed for wet locations
lighting for tubs and showers
recessed luminaires•render the upper-third of shower or tub area a little dimmer•do a better job of reducing glare•allow the use of higher wattage bulbs
CODE: All light fixtures installed within tub and shower spaces should be rated and marked “suitable for damp/wet locations”.
Switches shall not be installed within wet locations in tub or shower spaces or within reach while standing in the tub or shower unless installed as part of the listed tub or shower assembly.
CODE: Hanging fixtures [such as chandeliers over tubs] cannot be located within a zone of 3 feet horizontally and 8 feet vertically from the top of the bathtub rim or shower stall threshold.
ambient lighting
indirect lighting adds a warm overall glow•wall sconces•cove lighting
can find both in fluorescent or led lamps to comply with title 24
if higher ceilings, pendant-hung units are also a consideration
skylights
supplement/replace ambient lighting during day:•white opal acrylic•UV filters specified•if light-well is deep enough, low-maintenance fluorescent/led strip-lights can be used to keep skylight lit at night
exhaust fans
not required if operable windowsnice to have to remove steam and odors
make sure to specify separate switching for light & fan—if allowed by code
lighting analysis
lighting analysis
lighting analysis
lighting analysis