Instrumentacioni pojacavac

download Instrumentacioni pojacavac

of 3

description

Hijerarhija instrumentacionog pojacivaca

Transcript of Instrumentacioni pojacavac

  • V00

    R1

    1k

    VPARAM ET ERS:f _0 = 5kn = 20f _chan = 1k

    MAXIMUM STEP SIZE 20N

    E1

    sin(6.283*(f _0+n*f _chan*V(%IN+, %IN-))*time)EVALUE

    OUT+OUT-

    IN+IN-

    0

    f_chan - channel spacing

    f_0 - f at zero modulating voltage

    0

    out

    n - channel counter

    TRAN 2.4m

    V1

    TD = 0

    TF = 10uPW = 10uPER = 1.2m

    V1 = 0

    TR = 1m

    V2 = 1

    VCO

    0

    VCC

    U5A

    OP-471A

    3

    2

    411

    1

    +

    -

    V+

    V-

    OUT

    0

    R1

    1k1%

    V

    VEE

    V312

    R7

    10k1%

    VCC

    R6

    1k 1%

    R4

    1k 1%R3 10k

    1%

    V1

    FREQ = 1KVAMPL = 10mVOFF = 0

    U4A

    OP-471A

    3

    2

    411

    1

    +

    -

    V+V

    -

    OUT

    VCC

    R5

    10k 1%

    0

    U3A

    OP-471A

    3

    2

    411

    1+

    -

    V+

    V-

    OUT

    R2 10k1%

    OUT

    VEE

    VEE

    V2

    FREQ = 1KVAMPL = 10mVOFF = 0

    PHASE = 180

    VCC

    VEE

    0

    V4-12

    0 Instrumentacioni pojacavac

  • 00

    MIN

    MC/WORST CASE

    V2

    FREQ = 1KVAMPL = 10mVOFF = 0

    AC = 1

    R1

    39k1%

    MAXWORST CASE/SENSITIVITY

    Qbreakn

    Q1 RP

    22k1%

    C1

    10u

    V1

    R2

    82k1%

    RC

    4.3k1%

    0

    RE1

    3.3k1%

    0

    I

    RE2

    1001%

    HI

    .model Qbreakn NPN (IS=5F DEV/UNIFORM 10% BF=200 DEV/UNIFORM 80%)

    OUT

    Rg

    50 1%

    MC/WORST CASE

    DC SWEEP

    WORST CASE/SENSITIVITY

    V1

    C3

    10u

    V1

    12

    0

    0DC SWEEP

    VALUE LIST 12

    CE

    100U

    LO

    VALUE LIST 12

    Worst case (min i max struja kolektora)

    0

    0

    OUT

    V1

    12

    CE

    100U

    LO

    R2

    82k1%

    C3

    10u

    RC

    4.3k1%

    1k 1k 1

    WORST CASE/SENSITIVITY

    Qbreakn

    Q1C1

    10u

    0

    Rg

    50 1%

    .model Qbreakn NPN (IS=5F DEV/UNIFORM 10% BF=200 DEV/UNIFORM 80%)

    HI

    RE2

    1001%

    MIN

    0

    MC/WORST CASE

    V

    RE1

    3.3k1%

    MC/WORST CASEvdb(out) vdb(out)

    RP

    22k1%

    AC SWEEP

    WORST CASE/SENSITIVITY

    V2

    FREQ = 1KVAMPL = 10mVOFF = 0

    AC = 1

    0

    MAX

    1k 1k 1

    0

    R1

    39k1%

    AC SWEEP

    Worst case (min i max pojacanje)

  • 00

    0

    OUT

    Q2

    Q2N2222

    R2

    82k1%

    VD

    B

    R1

    39k1%

    RE2

    1001%

    C3

    10u

    YMAX

    Rg

    50 1%V2

    FREQ = 1KVAMPL = 10mVOFF = 0

    AC = 1

    0

    RC

    4.3k1%

    AC SWEEP

    C1

    10u

    MC/WORST CASE

    CE

    100U

    1 100meg 100

    Monte Carlo

    RP

    22k1%

    RE1

    3.3k1%

    0

    vdb(out) 100

    0

    V1

    12

    Frekvencijska karakteristika jednog pojacavaca

    hb2

    schematic3

    in out

    hb1

    schematic2

    outin

    V

    0

    V

    R2

    1k

    0

    V1

    TD = 10n

    TF = 10nPW = 10mPER = 20m

    V1 = -10m

    TR = 10n

    V2 = 10m

    R1

    1k

    0

    schematic2

    U1

    OPAMP

    +

    -

    OUT

    IC= 0+

    C1

    10n

    R1

    10k

    in

    out

    0

    IC= 0+

    R1

    1kin

    0

    out

    U2

    OPAMP

    +

    -

    OUT

    schematic3

    C1

    10n Hijerarhijski blokovi