To prevent accidents and damage to the appliance, you must readthese instructions before installing the appliance and using it for thefirst time.

en-US M.-Nr. 11 743 800

Contents

2

IMPORTANT SAFETY INSTRUCTIONS ............................................................ 4

Caring for the environment .............................................................................. 13

Guide to the ventilation hood ........................................................................... 14

Description of functions ................................................................................... 16

Operation............................................................................................................ 17Turning on the blower.......................................................................................... 17Selecting the power level .................................................................................... 17Delayed shut-down ............................................................................................. 17Turning off the blower.......................................................................................... 17Turning the overhead lighting on/off.................................................................... 17Power management ............................................................................................ 17

Turning power management on/off ................................................................ 18Safety shut-off..................................................................................................... 18

Energy-saving tips............................................................................................. 19

Cleaning and care ............................................................................................. 20Stainless steel housing........................................................................................ 20Grease filters ....................................................................................................... 21OdorFree Charcoal Filter ..................................................................................... 22

Disposing of charcoal filters ........................................................................... 23Changing a light bulb .......................................................................................... 23

Installation.......................................................................................................... 24Before installation................................................................................................ 24Removing the protective film............................................................................... 24Installation materials............................................................................................ 24Appliance dimensions ......................................................................................... 26Distance between cooktop and ventilation hood (S)........................................... 27Installation recommendations ............................................................................. 28Drilling diagram for wall mounting....................................................................... 28Plywood backing ................................................................................................ 29To install a plywood backing .............................................................................. 29Air venting ........................................................................................................... 30

Non-return flap ............................................................................................... 30Condensate .................................................................................................... 31Reducing Collar ............................................................................................. 31

Electrical connection ........................................................................................... 32

Customer Service .............................................................................................. 33Contact in the event of a fault ............................................................................. 33

Contents

3

Location of the data plate ................................................................................... 33MieleCare ............................................................................................................ 33

Technical data ................................................................................................... 34

IMPORTANT SAFETY INSTRUCTIONS

4

READ AND SAVE THESE INSTRUCTIONS

This appliance complies with current safety requirements.Improper use of the appliance can lead to personal injury andmaterial damage.

Read all instructions before installing or using the appliance for thefirst time. Only use the appliance for its intended purpose.

Keep these operating instructions in a safe place and pass themon to any future user.

Appropriate use

CAUTION: For General Ventilating Use Only. Do Not Use ToExhaust Hazardous Or Explosive Materials And Vapors.

This appliance is intended for residential use only. Use only asdescribed in these operating instructions.

This ventilation hood is not intended for outdoor use.

It must only be used to extract and clean vapors produced duringcooking. Any other use occurs at the owner's own risk.

This appliance is suitable for installation above gas or electriccooking surfaces.

Persons who lack physical, sensory or mental abilities, orexperience with the appliance should not use it without supervisionor instruction by a responsible person.

IMPORTANT SAFETY INSTRUCTIONS

5

Safety with children

Children must be kept away from the ventilation hood unless theyare constantly supervised.

Please supervise children in the vicinity of the hood and do not letthem play with it.

The LED ClearView lighting is very intense.Ensure that especially babies/small children don't look into the light.

Danger of suffocation. While playing, children may becomeentangled in packaging material (such as plastic wrapping) or pull itover their head, presenting the risk of suffocation. Keep packagingmaterial away from children.

Technical safety

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

- Use this appliance only in the manner intended by themanufacturer. If you have questions, contact Miele.

- Before servicing or cleaning the appliance, switch power off at theservice panel and lock the service disconnecting means toprevent power from being switched on accidentally. If the servicedisconnecting means cannot be locked, securely fasten aprominent warning device, such as a tag, to the service panel.

Unauthorized installation, maintenance, and repairs can causeconsiderable danger for the user. Installation, maintenance, andrepairs must only be carried out by a Miele authorized technician.

A damaged ventilation hood can be dangerous. Always check forvisible signs of damage. Never use a damaged ventilation hood.

IMPORTANT SAFETY INSTRUCTIONS

6

Be certain your appliance is properly installed and grounded by aqualified technician. To guarantee the electrical safety of thisappliance, continuity must exist between the appliance and aneffective grounding system. It is imperative that this basic safetyrequirement be met. If there is any doubt, have the electrical systemof the house checked by a qualified electrician.

Reliable and safe operation of this hood can only be guaranteed ifit has been connected to the electrical supply.

To avoid damaging the ventilation hood, make sure that theconnection data (voltage and frequency) on the data platecorrespond to the building's power supply before connecting theappliance.If in doubt, consult a qualified electrician.

Do not use a power bar or extension cord to connect theventilation hood to electricity. These are a fire hazard and do notguarantee the required level of appliance safety.

To ensure safe operation, only use the ventilation hood after it hasbeen properly installed.

This ventilation hood may not be used in non-stationary locations(e.g. on a ship).

Adequate ventilation must be provided when the hood is operatedsimultaneously with devices that burn gas or other fuels.

Only open the housing as described in the enclosed “Installationdiagram” and in the “Cleaning and care” section of this manual.Under no circumstances should any other parts of the housing beopened.Tampering with electrical connections or components andmechanical parts is highly dangerous to the user and can causeoperation faults.

IMPORTANT SAFETY INSTRUCTIONS

7

Defective components should be replaced by Miele original partsonly. Only with these parts can safety of the appliance be assured asintended by the manufacturer.

If the power cord is damaged, it must only be replaced by aqualified service technician.

During installation, maintenance, and repair work, the ventilationhood must be disconnected from the electrical supply. It is onlycompletely isolated from the electricity supply if one of the followingapplies:

- The circuit breakers on the electrical service panel are tripped.

- The screw-type fuses on the electrical service panel have beenremoved.

- The power cord (if present) has been unplugged from the socket(pull the plug not the cord).

Correct use

WARNING: TO REDUCE THE RISK OF A COOKTOP GREASEFIRE:

- a) Never leave surface units unattended at high settings. Boiloverscause smoking and greasy spillovers may ignite. Heat oils slowlyon low or medium settings.

- b) Always turn the hood on when cooking at a high heat.

- c) Clean the ventilation hood frequently. Grease should not beallowed to accumulate on the fan or filter.

- d) Use the proper pan size. Always use cookware appropriate forthe size of the cooking area.

Open flames are a fire hazard.The use of an open flame under the ventilation hood is notpermitted. To avoid the danger of fire, do not flambé or grill over anopen flame. When switched on, the ventilation hood could drawflames into the filter. Fat deposits could ignite, presenting a firehazard.

IMPORTANT SAFETY INSTRUCTIONS

8

WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS INTHE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THEFOLLOWING*:

- a) SMOTHER FLAMES with a close fitting lid, cookie sheet, ormetal tray then turn off the burner. BE CAREFUL TO PREVENTBURNS. If the flames do not go out immediately, EVACUATE ANDCALL THE FIRE DEPARTMENT.

- b) NEVER PICK UP A FLAMING PAN - You may be burned.

- c) DO NOT USE WATER, including wet dishcloths or towels - aviolent steam explosion will result.

- d) Use a fire extinguisher ONLY if:– 1) You have a class ABC extinguisher, and you know how to operate it.

– 2) The fire is small and contained in the area where it started.

– 3) The fire department is being called.

– 4) You can fight the fire with your back to an exit.

*Based on “Kitchen Fire Safety Tips” published by NFPA.

The ventilation hood may become damaged if exposed toexcessive heat from a gas cooktop.

- When using the ventilation hood over a gas cooktop, ensure thatany burners in use are always covered by cookware. Turn burnersoff when removing the cookware, even if doing so for just a shorttime.

- Select cookware that is suitable for the size of the burner.

- Adjust the flame so that it never extends up the sides of thecookware.

- Avoid overheating the cookware (e.g., when cooking with a wok).

Always turn the ventilation hood on whenever a burner is in use toprevent damage from condensation.

IMPORTANT SAFETY INSTRUCTIONS

9

Overheated oil and fat can ignite, causing fire damage to theventilation hood.Do not leave cookware, pans, and deep-fat fryers unattended whencooking with oil or fat. Similarly, never leave an open flameunattended when grilling.

Fat and debris deposits impair the proper functioning of theventilation hood.To ensure that cooking vapors are properly cleaned, never use theventilation hood without the grease filters in place.

There is a risk of fire if cleaning is not completed according to theinstructions in this manual.

Please note that the heat rising from the stovetop during cookingcan cause the ventilation hood to become very hot.Do not touch the housing or the grease filters until the ventilationhood has cooled down.

IMPORTANT SAFETY INSTRUCTIONS

10

Proper installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

- a) Installation work and electrical wiring must be done by qualifiedperson(s) in accordance with all applicable codes and standards,including fire-rated construction.

- b) Sufficient air is needed for combustion and exhausting of gasesthrough the flue (chimney of fuel burning equipment to preventback drafting. Follow the heating equipment manufacturer’sguideline and safety standards such as those published by theNational Fire Protection Association (NFPA) and the AmericanSociety for Heating, Refrigeration and Air Conditioning Engineers(ASHRAE), and the local code authorities.

- c) When cutting or drilling into the wall or ceiling, do not damageelectrical wiring and other hidden utilities.

- d) Ducted hoods must always be vented to the outdoors.

- e) Do not use this hood with any solid-state speed control device.

To determine whether a ventilation hood may be operated aboveyour cooking appliance, please refer to the information provided bythe appliance's manufacturer.

Safety regulations prohibit the installation of a ventilation hoodover solid fuel stoves.

An insufficient safety distance between the cooktop and theventilation hood can result in damage to the ventilation hood.The minimum safety distances between the top of the cooktop andthe bottom of the ventilation hood given in the “Installation” sectionof this manual must be observed, unless the cooktop manufacturerstates that a greater safety distance is required.If more than one cooking appliance is installed beneath theventilation hood, and they have different minimum safety distancesto the ventilation hood, select the greater distance.

IMPORTANT SAFETY INSTRUCTIONS

11

The information provided in “Installation” must be observed wheninstalling the ventilation hood.

Components can have sharp edges which may cause injury.Wear gloves to protect your hands.

When installing the exhaust duct, only use pipes or tubes made ofnon-flammable material. These can be obtained from your Mieledealer or from Miele Technical Service.

Exhaust air should not be vented into a chimney or vent flue whichis otherwise in use and should not be channeled into ducting whichventilates rooms with fuel-burning installations.

If exhaust air is to be extracted into a chimney or ventilation ductno longer used for other purposes, seek professional advice.

WARNING: TO REDUCE THE RISK OF FIRE USE ONLY METALDUCTWORK.

IMPORTANT SAFETY INSTRUCTIONS

12

Cleaning and maintenance

Never use a steam cleaner to clean the ventilation hood.The steam can reach the electrical components and cause a shortcircuit.

Accessories

Use only genuine original Miele parts. If parts or accessories fromother manufacturers are used, the warranty will become void.

Caring for the environment

13

Disposal of the packingmaterialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable and recyclable.

Ensure that any plastic wrappings,bags, etc. are disposed of safely andkept out of the reach of children.Danger of suffocation!

Disposal of your old applianceElectrical and electronic appliancescontain valuable materials. They alsocontain certain substances, compoundsand components which were essentialfor the proper functioning and safe useof the equipment. Handling thesematerials improperly by disposing ofthem in your household waste can beharmful to your health and theenvironment. Therefore, please do notdispose of your old appliance withregular household waste and followlocal regulations on proper disposal.

Consult with local authorities, dealers orMiele in order to dispose of and recycleelectrical and electronic appliances.Miele assumes no responsibility fordeleting any personal data left on theappliance being disposed. Pleaseensure that your old appliance is keptaway from children until removal.Observe safety requirements forappliances that may tip over or pose anentrapment hazard.

Guide to the ventilation hood

14

Guide to the ventilation hood

15

a Telescopic extension piece

b Duct cover

c Canopy

d Controls

e Grease filter

f Recirculation ventsOnly for recirculation mode

g Overhead lighting

h Charcoal filtersOptional accessories for recirculation mode

i Control for switching the blower on and off

j Controls for setting the blower power

k Button for switching the lighting on and off

Description of functions

16

The following functions are available onyour ventilation hood, depending on themodel:

Extraction mode

The air is drawn in and cleaned by thegrease filters and directed outside.

Recirculation modeThe recirculation mode requires arecirculation kit and OdorFree CharcoalFilter (available as optional accessories,see “Technical Data” for moreinformation)

The air is drawn in and first cleaned bythe grease filters and then by anOdorFree Charcoal Filter. The cleanedair is then recirculated back into thekitchen.

Operation

17

Turning on the blowerSwitch the blower on as soon as youstart cooking. This is to ensure thatvapors are captured right from the start.

Press the On/Off control .

The blower turns on at level 2. The symbol and 2 will light up in the blowerlevel display.

Selecting the power levelPower levels 1 to 3 are available for lightto heavy cooking vapors and odors.

For strong vapors and odors that aretemporarily produced when cooking,e.g., during searing, select the BBooster setting.

Select the power level you want bypressing the or control.

Reducing power down from theBooster setting

If power management is activated(default setting), the blowerautomatically switches back to level 3after 5 minutes.

Delayed shut-down It is advisable to run the blower for a

few minutes after cooking hasfinished.

This helps to neutralize any lingeringvapors and odors in the air.

It also reduces the risk of residuesaccumulating in the ventilation hoodand any resulting odors.

Turning off the blower Press the On/Off control  to turn

the blower off.

The symbol will go out.

Turning the overhead lightingon/offThe overhead lighting can be turned onand off separately from the blower.

To do this, press the lightingcontrol .

The  symbol will light up when theoverhead lighting is turned on.

Power managementThe ventilation hood is equipped with apower management system. Powermanagement helps to save energy. Itensures that the blower power level isreduced automatically and that thelighting is switched off.

- If the booster level is selected, theblower automatically switches tolevel 3 after 5 minutes.

- If the blower is set to level 3, 2, or 1,it switches back one blower settingafter 2 hours and then in 30-minuteintervals until the blower eventuallyswitches off.

- The overhead lighting will switch offautomatically after 12 hours.

Operation

18

Turning power management on/off

You can deactivate powermanagement.Keep in mind that this may increaseenergy consumption.

To set this option, turn off the fan andthe overhead lighting first.

Press the  and  buttons at thesame time for approx. 10 seconds,until 1 lights up.

Then, press the following buttons insuccession:

- the lighting button ,

- followed by the  button and then

- the lighting button .

If power management is turned on, the1 and B indicators will be continuouslylit.If it is turned off, the 1 and B indicatorswill flash.

Press the button to turn powermanagement off.

The 1 and B indicators will flash.

To turn it on, press the button.

The 1 and B indicators will becontinuously lit.

Confirm your choice with the On/Offbutton .

All the indicator lights will go out.

If the new setting is not confirmedwithin 4 minutes, the ventilation systemreverts to the previous setting.

Safety shut-offIf power management has beendeactivated, the ventilation hood willswitch itself off automatically after12 hours if it has been left on (blowerand overhead lighting).

To switch it back on, press the On/Off  control or the lightingcontrol .

Energy-saving tips

19

This hood operates in a very efficientand energy-saving manner. Thefollowing will help you to save evenmore energy when using it:

- Ensure that there is sufficientventilation in the kitchen whencooking. If there is insufficient air flowduring extraction mode, the hoodcannot operate efficiently, causingincreased operating noise levels.

- Always cook with the lowest possiblesetting. This produces fewer cookingvapors so that you can use a lowerhood power level and thereforebenefit from reduced energyconsumption.

- Check the power level selected onthe hood. A lower power level isgenerally sufficient for the majority ofcooking. Only use the booster levelwhen necessary.

- When a large volume of cookingvapors are being produced, switch toa high power level in good time. Thisis more efficient than operating thehood for longer to try to capturecooking vapors that have alreadybeen distributed throughout thekitchen.

- Make sure that you switch off thehood after use.

- Clean or change the filters at regularintervals. Heavily soiled filters reduceperformance, increase the risk of fireand are unhygienic.

Cleaning and care

20

Before proceeding with anymaintenance or cleaning task, theventilation hood must bedisconnected from the power supply,see “IMPORTANT SAFETYINSTRUCTIONS”.

Stainless steel housing

General information

Unsuitable cleaning agents candamage the surfaces and controlelements.Do not use any cleaning agentscontaining soda, acid, chloride, orsolvent.Do not use any abrasive cleaningagents, e.g., powder cleaners orcream cleaners and abrasivesponges, as well as pot scourers orsponges which have been usedpreviously with abrasive cleaningagents

Moisture in the ventilation hoodcan cause damage.Make sure that water does not getinto the ventilation hood.

Clean all surfaces and control buttonsusing a small amount of warm waterand liquid dish soap. Apply with asponge cloth.

After cleaning, wipe the surfaces dryusing a soft cloth.

Important information for applianceswith stainless steel surfaces

This information does not apply to thecontrol buttons.

Stainless steel surfaces can be cleanedwith a non-abrasive cleaning agentdesigned specifically for use onstainless steel.

To prevent the surfaces from quicklybecoming dirty again, we recommendtreating them with a stainless steel careproduct (available from Miele).

Important information for thecontrols

If soiling is not removed promptly, itcould cause the control elements toalter or discolor.Remove soiling immediately.

The surface of the control elementscan become damaged if they arecleaned using stainless steelcleaning agents.Do not use stainless steel cleaningagents on the control elements.

Cleaning and care

21

Grease filters

Risk of fireOversaturated grease filters are a firehazard.Clean the grease filters at regularintervals.

The re-usable metal grease filters in theappliance remove solid particles(grease, dust, etc.) from the kitchenvapors, preventing soiling of theventilation hood.

The grease filters must be cleaned atregular intervals.

Heavily soiled grease filters hinder airextraction and will lead to increasedlevels of soiling in the ventilation hoodand in the kitchen.

Cleaning intervals

Accumulated grease solidifies over alonger period of time and makescleaning more difficult. The greasefilters should therefore be cleaned every3 to 4 weeks.

Removing the grease filters

When handling the grease filter,be careful not to drop it.This can result in damage to the filterand the cooktop below.Make sure you hold the filter securelyat all times when handling it.

To remove a grease filter, release thelocking clip. Then, open the filter to a45° angle, unhook it, and remove itfrom the hood.

Cleaning the grease filters by hand

Clean the filters with a soft nylonbrush in a mild solution of hot waterand dish soap. Do not use undiluteddish soap.

Unsuitable cleaning agents

Unsuitable cleaners can cause damageto the filter surfaces if used regularly.Do not use any of the following:

- Lime removers

- Abrasive powders or abrasive liquids

- Aggressive all-purpose cleaners anddegreaser sprays

- Oven sprays

Cleaning the grease filters in adishwasher

Place the grease filters upright orslightly inclined in the lower basket.Ensure the spray arm is notobstructed.

Use a commonly available householddishwashing detergent.

Cleaning and care

22

In a Miele dishwasher use the“Normal” program.

Depending on the detergent used,cleaning the filters in a dishwashermay cause the inside filter surfaces tobecome discolored. However, this willnot affect the functioning of the greasefilters in any way.

After cleaning

After cleaning, leave the filters on anabsorbent surface to dry.

When removing the filters forcleaning, also clean off anyaccessible oil or fat buildup from thehousing. Doing so will prevent a firehazard.

Reinstall the grease filters. Wheninserting the filters, make sure thatthe locking clip is facing down.

If the filters have been installedincorrectly, you can insert a smallscrewdriver into the slit to disengagethe locking clip.

OdorFree Charcoal FilterWith recirculation mode, a charcoalfilter must be installed in addition to thegrease filters. The charcoal filter isdesigned to absorb cooking odors.

The charcoal filter is installed in thecanopy above the grease filters.

Charcoal filters are available to order viathe Miele Web Store, Miele TechnicalService (see end of this manual forcontact details), or from your Mieledealer. The model designations arelisted in the “Technical data” chapter.

How to install/replace a charcoalfilter

Remove the grease filters beforefitting or replacing a charcoal filter.

Take the charcoal filter out of itspackaging.

Press the charcoal filter into theframe.

Reinsert the grease filters.

Cleaning and care

23

When to change the OdorFreeCharcoal Filter

Replace the charcoal filter when it nolonger absorbs kitchen odorseffectively.It should be replaced at least every 6months.

Disposing of charcoal filters

Used charcoal filters can be disposedof with normal household waste.

Changing a light bulb

Only use the specified light bulbs.Other bulbs, for example halogenbulbs, may become damaged due tothe high generation of heat.

The light bulbs should be replaced withthe following:

Bulb type .............................. LED, GU10Power ............................................... 3W

Light bulbs are available from Miele orspecialist dealers.

Turn off the blower and the lighting.

The light bulbs can get very hotwhen in use.Allow the bulbs to cool down for afew minutes before changing them.

Disconnect the hood from theelectrical supply before replacing thelight bulbs (see “IMPORTANTSAFETY INSTRUCTIONS”).

Insert the lever supplied into the gapbetween the bulb and the bulbholder..

The bulb will then drop downwards.

Grip the light bulb, turn itcounterclockwise and take it out.

Screw the new bulb into the socketand push it upwards. Please followthe manufacturer's safetyinstructions.

Installation

*INSTALLATION*

24

Before installation

Before installation, it is importantto read the information contained inthis chapter and in the “IMPORTANTSAFETY INSTRUCTIONS” chapter.

Removing the protective filmThe housing components are coveredby a protective film to prevent themfrom damage during transport.

Please remove this film beforeinstalling the housing components. Itcan be peeled off easily without anyadditional tools.

Installation materials

3 wall bracketsfor securing the ventilation hood on thewall

8 screws measuring 5 x 60 mm and

8 plugs measuring 8 x 50 mmfor attaching to the wall

The screws and plugs aredesigned for use in solid walls only.Use different fasteners for other wallconstruction types.Make sure that the wall can supportthe load.

2 M6 locknutsfor mounting the appliance unit

2 screws measuring 3.9 x 7.5 mmfor securing the chimney

Montage

Installation

Montaje

M

ontaggio

Montering

Montagem

A

sennus

Installation planSee the installation plan for details ofthe individual steps involved in theinstallation of this appliance.Leave these instructions with theappliance for the consumer/user.

Information is subject to change. Pleaserefer to our website to obtain the mostcurrent product specification, technical& warranty information.

Installation

*INSTALLATION*

25

DU

W2

0

Conversion kit for recirculationmodeThe conversion kit contains an exhaustgrille, hose, and hose clips (notsupplied, but available as an optionalaccessory. See “Technical data”).

1 leverFor removing the bulbs

Installation

*INSTALLATION*

26

Appliance dimensions

The drawing is not to scale

Installation

*INSTALLATION*

27

a Extraction mode

b Recirculation

c Air vent positioned at the top for recirculation

de Installation area (only d is required for recirculation operation). Wall or ceilingarea for the ducting cutout and for the electrical outlet. For recirculationoperation, only an electrical outlet needs to be installed.

Exhaust connection 6" (150 mm)

Distance between cooktop and ventilation hood (S)Provided a larger distance is not given by the manufacturer of the cooktop, followthe minimum safety distances between a cooktop and the bottom of the hood.Please also observe the information contained in the “IMPORTANT SAFETYINSTRUCTIONS” section.

Minimum distance S

Cooking appliance Mieleappliance

Non-Mieleappliance

Electric Cooktops 24" (610 mm)

Electric Barbeques and Fryers 26" (660 mm)

Multiburner Gas Cooktops ≤ 43,000 BTU/hr (12.6 kW), no burner > 15,000 BTU/hr (4.5 kW).

26" (660 mm) 30" (760 mm)

Multiburner Gas Cooktops ≤ 73,800 BTU/hr (21.6 kW), no burner > 16,500 BTU/hr (4.8 kW)

30" (760 mm)

Multiburner Gas Cooktops > 73,800 BTU/hr (21.6 kW), or one of the burners > 16,500 BTU/hr (4.8 kW)

Not possible

Single Burner Gas Cooktops ≤ 20,500 BTU/hr (6 kW)

26" (660 mm) 30" (760 mm)

Single Burner Gas Cooktops > 20,500 BTU/hr (6 kW)≤ 27,600 BTU/hr (8.1 kW)

30" (760 mm)

Single Burner Gas Cooktops > 27,600 BTU/hr (8.1 kW)

Not possible

Installation

*INSTALLATION*

28

Installation recommendations- A distance of at least 26" (660 mm) is

recommended above electriccooktops to provide more workspaceand easier cooking under the hood.

- When selecting an installation height,always take the user height intoconsideration. Users should haveample space to work comfortably onthe cooktop and reach the ventilationhood controls with ease.

- Please note that the greater thedistance from the cooktop, the lesseffective the hood is at drawing in thecooking vapors.

- To achieve optimum vapor extraction,the hood must be centered over thecooktop, not to the side.

- The cooktop should be no wider thanthe hood. Preferably, it should benarrower for better extraction.

- The mounting area must be easilyaccessible. The ventilation hoodshould be easy to reach anddisassemble in case a service call isnecessary. This should be taken intoconsideration when planning theposition of cabinetry, shelves,ceilings or decorative elements in thevicinity of the ventilation hood.

Drilling diagram for wallmounting When drilling, please follow the

directions contained on theaccompanying installation sheet.

When installing a custom back wallwith pre-drilled holes, please refer tothe drilling distances in the drawingabove (screws ³/₁₆" (5 mm)).

* The dimension for the middle wallbracket is variable. It will depend on theposition of the wall vent and the socket.It should be set as low as possible.

Installation

*INSTALLATION*

29

Plywood backing

The majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be firmly attached tothe stud framing behind the drywall.If studs are not available in therequired locations, a plywoodbacking (min. ½" (13 mm) thick)spanning at least two studs must beinstalled.Failure to adequately support theweight as stated may result in theventilation system falling off the wall,causing personal injury and propertydamage.

If plywood backing is not needed,proceed to the included “Installationdiagram”.

To install a plywood backing

Determine and mark the location ofthe retaining plate for the canopyas outlined on the “Installationdiagram”.

Make a cutting line 3“ (76 mm) aboveand 3” (76 mm) below the outline ofthe retaining plate.

Find the studs to the left and rightof the mounting location by tappingthe wall or using a stud finder.

Mark a vertical cutting line along thecenter of each stud.

CAUTION: When cutting or drillinginto the wall or ceiling, do notdamage electrical wiring and otherhidden utilities.

Remove the drywall between thecutting lines and replace it withplywood of a matching thickness(min. ½" (13 mm) thick). Tape thejoints and refinish the wall.

Proceed to the enclosed “Installationdiagram” to complete the installation.

Installation

*INSTALLATION*

30

Air venting

WARNING: Danger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and toproperly exhaust air, the exhaustgases extracted by the hood shouldbe vented outside of the building only.Do not vent exhaust air into spaceswithin walls or ceilings or in attics,crawl spaces or garages.To reduce the risk of fire, only usemetal ductwork.Please read and follow the“IMPORTANT SAFETYINSTRUCTIONS” to reduce the risk ofpersonal injury. Follow all local buildingcodes when installing the hood.

Only use smooth pipes or flexibleducting made from approved non-flammable materials for ducting.

To achieve the most efficient airthroughput with the lowest noise levels,please note the following:

- The diameter of the vent ductingmust not be smaller than the cross-section of the vent collar (see“Appliance dimensions”). This appliesin particular when using flat ducting.

- The ducting should be as short andstraight as possible.

- Only use wide radius bends.

- The ducting must not be kinked orcompressed.

- All connections must be strong andairtight.

- If the ducting has flaps, these mustbe opened whenever the ventilationhood is switched on.

Any constriction of the air throughputwill reduce extraction performanceand increase operating noise.

Ventilation stack

If the exhaust air is to be ducted into aflue, the ducting must be directed in theflow direction of the flue.

If the flue is used by several ventilationunits, the cross-section of the flue mustbe large enough.

Non-return flap

Use a non-return flap in the ventsystem.

A non-return flap ensures that when theventilation hood is not in operation, theduct is closed to prevent unwantedexchange of room air and outside air.

If the exhaust is ducted through anoutside wall, a Miele wall vent or roofvent (available as an optionalaccessory) is recommended. Both ofthese have a built-in non-return flap.

If the on-site vent system does not havea non-return flap, you can purchase oneas an optional accessory.

Installation

*INSTALLATION*

31

Condensate

If the ducting is to run through coolrooms or ceiling space, for example, thesignificant variations in temperaturebetween the different areas can causecondensate to form. Insulate theducting to reduce temperaturevariations.

If the ducting is to be laid horizontally, itmust be laid with a downwards slopinggradient of at least ³/₈" (1 cm) per meter.This is to ensure that condensatecannot drain back into the ventilationhood.

In addition to insulating the ducting, it isadvisable to also install a condensatetrap for collecting and evaporating anypotential condensate.

Condensate traps for 5" (125 mm) or6" (150 mm) diameter ducting areavailable as optional accessories.

When installing a condensate trap,ensure that it is positioned verticallyand as closely as possible to the

ventilation hood above the exhaustvent. The arrow on the casing indicatesthe direction of airflow.

Miele will not accept warranty claimsfor any functional defects or damagecaused by inadequate ducting.

Reducing Collar

(optional accessory)

If you would like to reduce theenvironmental impact of your ventilationsystem by limiting the CFM output theReducing Collar can be installed. Itreduces the air flow to less than400 CFM. Check local building codesfor max. CFM requirements.

Push the Reducing Collar on theexhaust port of the blower.

Push the exhaust hose over it.

Secure both with a hose clamp.

Installation

*INSTALLATION*

32

Electrical connection

WARNING: TO REDUCE THE RISKOF FIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS, OBSERVETHE FOLLOWING:All electrical work should beperformed by a qualified electricianin strict accordance with nationalregulations (for USA: ANSI-NFPA 70)and local safety regulations.Installation, repairs and other workby unqualified persons could bedangerous.Ensure that power to the appliance isOFF while installation or repair workis performed.Verify that the voltage, load andcircuit rating information found onthe data plate (see "TechnicalService"), match the householdelectrical supply before installing thehood.Use only with ventilation hood cord-connection kits that have beeninvestigated and found acceptablefor use with this model hood.If there is any question concerningthe electrical connection of thisappliance to your power supply,please consult a licensed electricianor call Miele’s Technical ServiceDepartment.

WARNING: THIS APPLIANCE MUSTBE GROUNDED

Grounding Instructions

WARNING - Improper grounding canresult in a risk of electric shock.

This appliance must be grounded. Inthe event of an electrical short circuit,grounding reduces the risk of electricshock by providing a path of leastresistance. This appliance is equippedwith a cord having a grounding wirewith a grounding plug.

If there is any doubt, have the electricalsystem of the house checked by aqualified electrician.

Do not use an extension cord. If thepower supply cord is too short, have aqualified electrician install an outlet nearthe appliance.

The plug must be plugged into anoutlet that is properly installed andgrounded.

WARNING - Grounding instructions(Canada)The grounding-type attachment plugshall be connected to a grounding-type receptacle installed inaccordance with CSA C22.1-12,Canadian Electrical Code, Part I.

Customer Service

33

Contact in the event of a faultIn the event of a fault which you cannotremedy yourself, please contact yourMiele dealer or Miele Customer Service.

You can book a Miele Service Callonline at www.miele.com/service.

Contact information for MieleCustomer Service can be found at theend of this document.

Please quote the model identifier andserial number of your appliance (SN)when contacting Miele CustomerService. Both pieces of information canbe found on the data plate.

Location of the data plateThe data plate is visible once you haveremoved the grease filters.

WarrantyFor further information, please refer toyour warranty booklet.

MieleCare

This service is available in USA only.

MieleCare, our Extended ServiceContract program, gives you theassurance of knowing that yourappliance investment is covered by5 years of worry free ownership.MieleCare is the only Extended ServiceContract in the industry that guaranteesrepairs by a Miele Authorized ServiceProvider using genuine Miele parts.Only genuine Miele parts installed byfactory trained professionals canguarantee the safety, reliability, andlongevity of your Miele appliance.

Please note that unless expresslyapproved in writing by Miele’s Servicedepartment, Extended ServiceContracts offered by other providers forMiele products will not be recognizedby Miele. Our goal is to preventunauthorized (and untrained) servicepersonnel from working on your Mieleproducts, possibly doing furtherdamage to them, you and/or yourhome.

To learn more about MieleCareExtended Service Contracts, pleasecontact your appliance dealer or visit usonline at:www.mieleusa.com

Technical data

34

Blower motor 350 W

Overhead lighting

PUR 68 W, PUR 88 W 2 x 3 W

PUR 98 W 3 x 3 W

Total connected load

PUR 68 W, PUR 88 W 356 W

PUR 98 W 359 W

Supply voltage, frequency 120 V AC, 60 Hz

Fuse 15 A

Power cord length 4' 11" (1.5 m)

Weight

PUR 68 W 46.2 lbs (21 kg)

PUR 88 W 50.6 lbs (23 kg)

PUR 98 W 55 lbs (25 kg)

Optional accessories for recirculation mode

DUW 20 conversion kit to change from vented mode to recirculation mode andDKF 12-900 OdorFree Charcoal Filter.

9 Independence WayPrinceton, NJ 08540Phone:Fax:www.mieleusa.com

U.S.A.Miele, Inc.

National Headquarters

Please have the model and serial numberof your appliance available whencontacting Customer Service.

CanadaImporterMiele Limited

Headquarters and Miele Centre

800-843-7231609-419-4298

Customer Service & SupportPhone:Fax:[email protected]

161 Four Valley DriveVaughan, ON L4K 4V8www.miele.ca

888-99-MIELE(64353)888-586-8056

Customer Care CentrePhone:

[email protected]

800-565-6435905-532-2272

International HeadquartersMiele & Cie. KGCarl-Miele-Straße 2933332 GüterslohGermany