Step 1. After the patient is draped, open the sterile pouch and remove the CSR wrap. Unfold C-Armor ® and present to another sterile team member. Step 2. Remove the release paper located on the top, left, and right sides to expose the adhesive tape. Step 3. Center C-Armor ® on the surgical site or area of interest, and adhere to the patient drape above the sterile field line. (Note: C-Armor ® should be applied before electrocautery or suction tubing are placed to avoid interference.) Step 4. Exert pressure on the adhesive using your hand from within the pouch to avoid contamination. Step 5. When lateral imaging is required, release C-Armor ® fastener tabs by gasping the support structure using your thumb and index finger. Step 6. Separate the fasteners by applying counter pressure toward the table with the middle, ring, and small fingers. Step 7. Expand C-Armor ® to allow the C-Arm to rotate into the sterile pouch. Step 10. Rotate the C-Arm back to the vertical position, collapse C-Armor ® toward the table and reconnect the fasteners. Step 8. Once the X-Ray tube is at the full lateral position, you may release C-Armor ® . C-Armor ® will hold its position above the sterile field line. Step 9. When lateral imaging is complete, grasp the support system and hold above the table height. INSTRUCTIONS FOR USE

Transcript of INSTRUCTIONS FOR USE€¦ · Step 1. After the patient is draped, open the sterile pouch and remove...

Page 1: INSTRUCTIONS FOR USE€¦ · Step 1. After the patient is draped, open the sterile pouch and remove the CSR wrap. Unfold C-Armor® and present to another sterile team member. Step

Step 1.After the patient is draped, open the sterile pouch and remove the CSR wrap. Unfold C-Armor® and present to another sterile team member.

Step 2.Remove the release paper located on the top, left, and right sides to expose the adhesive tape.

Step 3.Center C-Armor® on the surgical site or area of interest, and adhere to the patient drape above the sterile �eld line. (Note: C-Armor® should be applied before electrocautery or suction tubing are placed to avoid interference.)

Step 4.Exert pressure on the adhesive using your hand from within the pouch to avoid contamination.

Step 5.When lateral imaging is required, release C-Armor® fastener tabs by gasping the support structure using your thumb and index �nger.

Step 6.Separate the fasteners by applying counter pressure toward the table with the middle, ring, and small �ngers.

Step 7.Expand C-Armor® to allow the C-Arm to rotate into the sterile pouch.

Step 10.Rotate the C-Arm back to the vertical position, collapse C-Armor® toward the table and reconnect the fasteners.

Step 8.Once the X-Ray tube is at the full lateral position, you may release C-Armor®. C-Armor® will hold its position above the sterile �eld line.

Step 9.When lateral imaging is complete, grasp the support system and hold above the table height.

INSTRUCTIONS FOR USE

Page 2: INSTRUCTIONS FOR USE€¦ · Step 1. After the patient is draped, open the sterile pouch and remove the CSR wrap. Unfold C-Armor® and present to another sterile team member. Step

1

Code Description

5523 C-Armor® Drape

5536 C-Armor® Kit/Pack

Quantity

Box of 12

Box of 12

Defend the Sterile Field

COPYRIGHT © 2016 TIDI PRODUCTS, LLC. ALL RIGHTS RESERVED.

570 Enterprise Drive | Neenah, WI USA 54956 C-Armor registered trademark is property of TIDI Products, LLC. For U.S. and foreign patent information, see go.tidiproducts.com/patents.

CARMORIFU-0916

For more information or to place an order, visit TIDIProducts.com

or call 1.800.521.1314.

1. Guidelines for Perioperative Practice (2015 AORN, Inc. Tech IV.a.1) AORN does not endorseany company’s products or services. AORN is a trademark of AORN, Inc.

C-Armor® is the only solution designed for procedures with multiple C-Arm swings, providing 5-sided protection

to maintain the sterile field, and reducing the need for excess materials needed throughout the procedure.

Recommended practice AORN 2015“Unsterile equipment...should be covered on the top, bottom, and sides with sterile

barrier materials before being introduced to or brought over a sterile field.”