Instruction Manual - HiLipo CONTOUR - Johari Digital€¦ · Ÿ Some patients may experience skin...
Transcript of Instruction Manual - HiLipo CONTOUR - Johari Digital€¦ · Ÿ Some patients may experience skin...
Register your product and get support at
www.joharidigital.com
INSTRUCTION MANUAL
Hi-LipoCo n t o u r
TABLE OF CONTENTS
Sr. Particulars Page No.
1
1.1
1.2
1.3
1.4
1.5
1.6
2
2.1
2.2
2.3
3
4
4.1
4.2
5
6
7
8
9
INSTRUCTIONS FOR THE USER OF HILIPO CONTOUR
Warnings
Danger
Indication for use
Contraindications
Precautions
Adverse Reaction
INTRODUCTION
Overview
Introduction
Features
ACCESSORIES
SPECIFICATIONS
System Specification
Waveform Specifications
CONTROL & FUNCTIONS
HOW TO OPERATE
TROUBLESHOOTING
MAINTENANCE
WARRANTY
1
1
2
2
3
3
3
4
4
4
4
5
5
5
6
7
8
13
14
15
1. INSTRUCTIONS FOR THE USER OF HILIPO CONTOUR
INSTRUCTION MANUAL HILIPO CONTOUR
www.joharidigital.com1
Please read this instruction manual carefully before using the device as it is unsafe to start device without
reading the manual. Instructions on the following pages will show you proper handling of the device in
general manner. You should be particularly familiar with the required treatment and precaution before
proceeding.
CAUTION The device must be used only under the supervision of licensed practitioner or :
technically trained person.
Ÿ Do Not operate this unit in an environment where other devices are being used that intentionally
radiates electromagnetic energy in an unshielded manner.
Ÿ Do Not use sharp objects such as a pencil point or ballpoint pen to operate the button on the touch
screen.
Ÿ This unit should be operated in temperatures between 170 and 380C, transported and stored in
temperatures between -300 and +600C, with Relative Humidity ranges from 30% to 60%.
Ÿ Inspect all cables before each use.
Ÿ The Hi lipo Contour system is not designated to prevent the ingress of water or liquid. Ingress of water
and liquid could cause malfunction of internal components of the system and therefore create a risk of
injury to the user.
Ÿ Inspect cable and associated connector before each use.
1.1 Warnings
Ÿ The long term effects of electrical stimulations are unknown.
Ÿ Stimulation should not be applied over the carotid sinus nerves, particular in the patient with known
sensitivity to the carotid sinus reex.
Ÿ Stimulation should not be applied transthoracically in that the introduction of electric current into the
heart may cause cardiac arrhythmias.
Ÿ Stimulation should not be applied transcerebrally.
Ÿ Electrode should not be applied over the neck or mouth, or anywhere else on the head. If stimulation is
applied over the neck or mouth, especially sever spasm of the laryngeal and pharyngeal muscle may
occur and the contraction may be strong enough to close the airway or cause difculty in breathing.
Ÿ Stimulation should be applied only to normal intact skin, and stimulation should not be applied over
open wounds, over swollen, infected, or inamed areas or skin eruptions e.g. phlebitis,
thrombophlebitis varicose vein etc.,
Ÿ Stimulation should not be applied over, or in proximity to, cancerous lesions.
Ÿ TENS should be used only under the continued supervision of a physician or licensed practitioner.
Ÿ TENS waveform have no curative value.
Ÿ If you have any medical concerns, such as severe medical illness, epilepsy or seizures, or recent
surgery, please consult your doctor before undergoing the therapy.
Ÿ Potential adverse reaction may include electrode burns, skin irritation, or redness.
Ÿ Make certain the unit is electrically grounded by connecting only to a grounded electrical service
receptacle conforming to the applicable national and local electrical codes.
Ÿ To prevent electrical shock, disconnect the unit from the power source before attempting any
maintenance procedures.
1.2 Danger
Ÿ Improper handling or use of device may result in serious injury.
Ÿ Stimulus delivered by the TENS waveforms of the device, in certain congurations will deliver a charge
of 25 micro coulombs (µC) or greater per pulse and may be sufcient to cause electrocution. Electric
current of this magnitude must not ow through the thorax because it may cause cardiac arrhythmia.
Ÿ Patient with an implanted Neurostimulation device must not be treated with or be in close proximity to
any shortwave diathermy, microwave, diathermy, therapeutic ultrasound diathermy or laser diathermy
anywhere on their body. Energy from diathermy (shortwave, microwave, ultrasound and laser) can be
transferred through the implanted Neurostimulation system, can cause tissue damage and can result
in severe injury or death. Injury, damage, or death can occur during diathermy therapy even if the
implanted Neurostimulation system is turned “off”.
Ÿ Handling, cleaning, and disposal of components and accessories that have come in contact with
bodily uids according to National, Local and Facility rules, regulations and procedures.
2
INSTRUCTION MANUAL HILIPO CONTOUR
Ÿ Keep electrodes separated during treatment. Electrode in contact with the each other could result in
improper stimulation or skin burns.
Ÿ Output current density is related to electrode size, inadequate electrode contact area may result in
patient injury. Please consult the enclosed manufacturer's table for recommended electrode area to
be used with the device. If any additional question arises regarding the electrode size, consult a
licensed practitioner or the manufacturer prior to the therapy session.
Ÿ Stimulation should not be applied over the spinal cord area following laminectomy.
Ÿ The device should not be applied on the anterior aspect of the chest (i.e. thorax)
Ÿ To be used under doctor prescription and control (no suggestions but obligation).
Ÿ Operation in close proximity (e.g. 1m) to a shortwave or microwave therapy EQIPMENT may produce
instability in the stimulator output.
Ÿ Current densities for any electrodes exceeding 2mA r.m.s./cm2 may require the special attention of the
USER.
Ÿ Care must be taken when operating this equipment around other equipment. Potential
electromagnetic or other interference could occur to this or to the other equipment. Try to minimize this
interference by not using other equipment in conjunction with it.
1.3 Indication for Use
Hi lipo contour is indicated to be used as
Interferential (IFC) and TENS for:
Ÿ Symptomatic relief of Chronic, intractable pain.
Ÿ Management of pain associated with post-traumatic or post operative conditions.
Russian For:
Ÿ Relaxation of muscle spasms
Ÿ Prevention or retardation of disuse atrophy
Ÿ Increase local blood circulation
Ÿ Muscle re-education
Ÿ Maintaining or increasing range of motion
Ÿ Immediate post-surgical stimulation of cell muscle to prevent venous thrombosis
3
INSTRUCTION MANUAL HILIPO CONTOUR
1.4 Contraindications
Use of device is contradicted for:
Ÿ People with any surgical implant.
Ÿ People with Heart diseases, heart murmur, irregular heart rate, With a pacemaker or heart rate
balancer
Ÿ During Pregnancy
Ÿ People with Epilepsy, Undergoing treatments for cancer
Ÿ People below 18 year
Ÿ People suffering from cholesterol.
Ÿ People with thrombosis and / or thrombophlebitis. .
Ÿ People treated with anticoagulants. .
Ÿ Peoples with malignancies. .
Ÿ People with Liver or Kidney disorder
Ÿ People not sensitive to temperature
Ÿ People with Immuno-Suppressive Disorders
Ÿ People who suffer decompensated arteriopathy.
Ÿ Critical ischemia of lower limbs
Ÿ Abdominal or inguinal hernia
Ÿ Any other serious illness/disease not yet listed above.
1.5 Precautions
Ÿ Caution should be used for patient with suspected or diagnosed heart problems.
Ÿ Caution should be used for patient with suspected or diagnose epilepsy.
Ÿ Caution should be exercised in presence of following:
Ÿ When there is tendency of hemorrhage following acute trauma and fracture.
Ÿ Following recent surgical procedures when muscles contraction may disrupt the healing process.
Ÿ Over the menstruation or uterus.
Ÿ Over area of Skin which lack normal sensation.
Ÿ Electrode placement and stimulation setting should be based on guidance of the prescribing
practitioner and physician.
Ÿ The effectiveness of TENS waveforms is highly dependent upon patient selection by a qualied
person.
Ÿ Device should be kept out of the reach of children.
Ÿ Device should only use with the electrodes cable and electrodes recommended for use by
manufacturer.
Ÿ Headache and other painful sensation have been reported during or following electrical stimulation.
Lowering the intensity may reduce or eliminate these sensations.
1.6 Adverse reaction
Ÿ Skin irritation and burn beneath the electrodes have been reported with the use of stimulation.
Ÿ Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or
electrical conductive medium. This irritation can usually be reduced by using an alternative conductive
medium or an alternative electrode placement.
2.1 Overview
Electronic Muscle Stimulation is an advanced technique used world-wide for toning, reshaping, rming
thighs, buttocks, and for maintaining muscle denition. Overtime, muscles lose their conditioning from
lack of exercise. Muscles can now be re-educated to maintain a toned appearance through EMS.
Electronic Muscle Stimulation Therapy targets and sends signals to weak muscles telling the muscles to
contract. This therapy can be described as a gentle tingling that develops into a massage-like sensation
as the frequency is increased. The therapy normally lasts anywhere from 10-35 minutes, often with the
use of hot or cold compresses depending on the area.
2.2 Introduction
HI- LIPO Contour is the latest technology by using a revolutionary muscle stimulation process that helps
in contour body lines, lose weight and tone muscles through electro stimulation.
Hi Lipo Contour is used to strengthen and tone muscles, anti-cellulite treatment and encourage removal
of fat deposits (liposis). Electrodes are placed on the area, and a mild current will articially stimulate the
muscles in that area.
The treatment is scientically proven to stimulate muscles in body which is the equivalent of a massive
gym session. The impulses are generated by a device and delivered through electrodes on the skin in
direct proximity to the muscles to be stimulated. The impulses mimic the action potential coming from the
central nervous system, causing the muscles to contract. The electrodes are pads that adhere to the skin.
By creating electronic pulse to stimulate special points on the body, this kind of function can effectively
regulate bio-electric and endocrine system and accelerate metabolism, reaching remarkable effect of
weight losing and skin tightening
2.3 Features
Ÿ Beauties body in a medical way.
Ÿ Non-aggressive and 100% natural.
Ÿ Non-Invasive body reshaping treatment.
Ÿ Uses Bio-Stimulation Technology that electronically simulates the body's impulses to reshape the
body.
Ÿ Power Sequence for Toning of muscles.
Ÿ Special waveforms are used in this slimming device for deep and precise penetration to break adipose
tissues.
Ÿ LCD Touch Screen for easy operations.
Ÿ Classic vector for immediate inch loss.
Ÿ Pre-Programmed Protocols.
Ÿ Fast, Intensied and Long Lasting results.
4
2. INTRODUCTION
INSTRUCTION MANUAL HILIPO CONTOUR
3. ACCESSORIES
Hi Lipo Contour comes with the complete set of accessories needed for the treatment. List of accessories
is as follow:
QuantityS.No.
1
2
3
4
5
6
7
8
9
Particulars
Adaptor 24VDC 2.5A
Elastic SB-07 Black Size 3" x 24" w/2 Side Hooks
Elastic SB-07 Black Size 3" x 42" w/2 Side Hooks
Electrode Carbon Size: 3”
Tube Gelly 100 ml
Lead Wire 5 Pin 4 Core
AC Cord
Instruction Manual
Warranty Card
4. SPECIFICATIONS:
System Specication
Length
Width
Height
Standard Weight
Power (Ultra Beauty Unit)
Ultrasound Cavitation
Operating Temperature
Storage Temperature
+24Volts DC, 2.5A
Class II
Input
Electric Class
Electrical Type
TYPE BF
Between 17°C to 38°C
Between -30°C to 60°C
5
4.1 System Specication
Height
Length
Width
INSTRUCTION MANUAL HILIPO CONTOUR
1
4
2
16
1
4
1
1
1
330mm
340mm
165mm
4.5 Kg
4.2 WAVE FORM SPECIFICATION
Treatment Time Selectable: 1 - 60 Min.
6
INSTRUCTION MANUAL HILIPO CONTOUR
TENS 1
Lift & Tone Mode
Waveform
Carrier Frequency
Sweep Low Beat Frequency
Sweep High Beat Frequency
Sweep Time
Intensity
Conguration
Mode
Symmetrical Biphasic
200 µsec;
40 Hz;
100Hz;
4 Sec;
0-75 Vpeak-peak @ load 500ohms;
2P;
CV(Constant Voltage);
TENS 2
Lift & Tone Mode
Waveform
Phase Duration
Frequency
Intensity
Conguration
Mode
Symmetrical Biphasic
350 µsec;
30 Hz;
0-75Vpeak-peak @ load 500ohms;
2P;
CV(Constant Voltage);
TENS 3
Lift & Tone Mode
Symmetrical Biphasic
350 µsec;
100 Hz;
100%;
4Sec/4Sec;
6 Sec;
4 Sec;
0-75Vpeak-peak @ load 500ohms;
2P;
CV(Constant Voltage);
Waveform
Phase Duration
Frequency
Amplitude Modulation
Ramp Up/Down Time
Contraction Time
Relaxation Time
Intensity
Conguration
Mode
Waveform
Carrier Frequency
Sweep Low Beat Frequency
Sweep High Beat Frequency
Sweep Time
Intensity
Conguration
Mode
IFC (Interferential 4 Pole)
Sine Wave
4000Hz
1Hz
100 Hz
20 Sec;
0-80Vpeak-peak @ load 500ohms;
4P;
CV(Constant Voltage);
Sculpt Mode
Waveform
Carrier Frequency on CH#1
Carrier Frequency on CH#2
Intensity
Channel Mode
Amplitude Modulation
Ramp Up Time
Ramp Down Time
Contraction Time
Relaxation Time
Conguration
Mode
Russian 4P
Step Sine Wave
2500Hz
2570Hz
0-80Vpeak-peak @ load 500ohms;
Co-Contract;
100%;
2 Sec;
2 Sec;
8 Sec;
4 Sec;
2P;
CV(Constant Voltage);
Strengthen Mode
5 Controls & Functions
7
INSTRUCTION MANUAL HILIPO CONTOUR
Hi Lipo contour is an innovative touch screen desktop device providing electrical stimulation through electrodes.
1
2
3
45
1. Touch Screen Operating Display
2. Intensity Controller
3. Power Switch
4. Adaptor Input Plug
5. Output Sockets
8
6. HOW TO OPERATE
Areas that can be Sculpted/Contoured with Hi Lipo
Legs & Buttocks:
Hi Lipo can help reduce the appearance of stretch marks, cellulite, scarring and dimpling using the
Electrical Stimulation. The best procedure for cellulite is nally here! See benets in skin tightening, lift
sagging areas, muscle toning, hydration and overall appearance of the skin.
INSTRUCTION MANUAL HILIPO CONTOUR
Abdomen:Tighten and tone the stomach and love handles with this treatment designed to sculpt your waist line. See
a reduction measured in inches .
Arm Sculpting:
Experience a relaxing treatment resulting in sleeker arms. Flabby arms are toned and tightened while
seeing improvements in sagging and loose skin.
Treatment procedures:
1. Preparation of the patient:
Ÿ The skin in the area of electrode placement should be cleaned thoroughly.
Ÿ Special gels, sprays or water is applied to the skin as a condition medium for better stimulation.
Ÿ Electrodes should be xed in position, using mending tapes to maintain good contact throughout
the treatment period.
Device installation:
Insert 24 V DC Adaptor pin Insert all electrode cables as shown in gure
Switch on the Device Insert all electrode cables as shown in gure
9
INSTRUCTION MANUAL HILIPO CONTOUR
Following Display will Appear:
Sculpt
Lift & Tone
Strengthen
Hi-Lipoc o n t o u r
Home Screen
To start a treatment Tap on Sculpt Mode
Sculpt
Lift & Tone
Strengthen
?
Hi-Lipoc o n t o u r
Sculpt
60 Min0 Min
1 2 3 4
Hi-Lipoc o n t o u r
100
90
80
70
60
50
40
30
20
10
100
90
80
70
60
50
40
30
20
10
50:00
STOPTIME
STOP ALL
Tap on Channel 1 to start the treatment
as channel 1 is selected; the time bar will lighten up.
Sculpt
60 Min0 Min
1 2 3 4
Hi-Lipoc o n t o u r
100
90
80
70
60
50
40
30
20
10
100
90
80
70
60
50
40
30
20
10
50:00
STOPTIME
STOP ALL
Sculpt
60 Min0 Min
1 2 3 4
Hi-Lipoc o n t o u r
100
90
80
70
60
50
40
30
20
10
100
90
80
70
60
50
40
30
20
10
50:00
STOPTIME
STOP ALL
10
INSTRUCTION MANUAL HILIPO CONTOUR
Sculpt
60 Min0 Min
1 2 3 4
Hi-Lipoc o n t o u r
100
90
80
70
60
50
40
30
20
10
100
90
80
70
60
50
40
30
20
10
50:00
STOPTIME
STOP ALL
Now tap on channel 1 again to start the channel 1 treatment; the circle of channel 1 will glow. Rotate the intensity controller to increase or decrease the intensity. As intensity will increased the intensity bar will lighten up with lled indication colors
Other Channels also can be start during the treatment as same as channel 1.
Sculpt
60 Min0 Min
1 2 3 4
Hi-Lipoc o n t o u r
100
90
80
70
60
50
40
30
20
10
100
90
80
70
60
50
40
30
20
10
50:00
STOPTIME
STOP ALL
Tap on Stop button to stop the selected channel or tap on Stop All button to stop all the channels.
Tap on Home Button for go to Home screen
Sculpt
Lift & Tone
Strengthen
?
Hi-Lipoc o n t o u r
From Home Screen other treatment can be started as Sculpt mode
1A
1B
1A
1B 2B
2B
2A
2A
Buttocks Back Thighs
1B
1A
1B
1A 2B
2B
2A
2A
Front Thighs
1A
1B
1B
1A
2B
2A
2A
2B
Abdomen
1B
1A
1A
1B
2B
2B
2A
2A
3A
3B
3A
3B
11
INSTRUCTION MANUAL HILIPO CONTOUR
Placement of electrode should be as shown in following images during the treatment for sculpt mode.
1A 2B
1B2A
1B
1A
2A 2B
Front Thighs
2B
2B
2A
1A
1B
2B
2A
1A1B
Back Thighs
Buttocks
1A 2A
1A 2A1B 2B
1B 2B
Abdomen
1B
1B
1A
1A
2A
2A
2B
2B
12
INSTRUCTION MANUAL HILIPO CONTOUR
Placement of electrode should be as shown in following images during the treatment for Lift & Tone and Strengthen mode.
13
INSTRUCTION MANUAL HILIPO CONTOUR
7. TROUBLESHOOTING
Observation Possible Cause Remedy
None of the displays are lighting up after switching on the rocker switch
Internal Error Turn off the rocker switch and inform the supplier
Uncomfortable stimulation Lack of conductive gel Pause the stimulation, Put more conductive gel and reposition the probe electrodes on the treatment area. Then restart treatment.
Skin irritation at applicator contact site
Improper contact Wet or change the Applicator
Sudden high Intensity While increasing intensity level
Increasing too fast Increase slowly giving time to patient to his comfort
Weak stimulation or no stimulation even at maximum intensity setting
Electrode conduction is low or lead wire is worn out
Change Applicator Change Applicator wires
Electrode is not directly against your clean, dry skin
Make sure the plastic liner is removed from your electrode and place it directly against your clean, dry skin.
Intensity level might not be high enough
The intensity must be at least 15% before you will feel anything
Electrodes may not be properly positioned
Turn the device off, Put more conductive gel and reposition the electrodes on the treatment area. Then restart treatment.
The Lead-Wire module is not inserted correctly
Make sure the wires are securely attached
No Sensation
14
INSTRUCTION MANUAL HILIPO CONTOUR
MAINTENANCE
Cleaning
Ÿ The soiled unit should be cleaned with a damp cloth.
Ÿ Make sure hands are clean and dry during the operation.
Ÿ Clean the probe and applicator with a damp cloth as well.
Warning
Ÿ Do not pull out hand held applicators.
Ÿ Eelectrode wires should be kept loosely winded or breakage may occur.
Storage
Ÿ Keep the unit properly covered, when not in use. This will help to keep out of dust.
Ÿ Make special space to keep the unit, after the treatment is over.
Ÿ Do not store the unit in a damp environment. Dampness may affect device and cause rust.
Electrode Care
Ÿ 1. Carbon electrode should be regularly cleaned with mild soap and water to remove skin oils, gel and
dirt.
Ÿ 2. Do not immerse electrode in any liquid.
Ÿ 3. Thoroughly dry the electrode before using.
Ÿ 4. Store the electrode in a resalable pouch or plastic bag.
Ÿ 5. If electrodes gets soiled or have too much gel deposited on them, it is advised that you replace the
electrode after long periods of usage.
List of accessories : (in case of replacement or ordering) For contact details please see the back cover page of the manual
S.No.
1
2
3
4
5
6
7
8
9
Particulars
Adaptor 24VDC 2.5A
Elastic SB-07 Black Size 3" x 24" w/2 Side Hooks
Elastic SB-07 Black Size 3" x 42" w/2 Side Hooks
Electrode Carbon Size: 3”
Tube Gelly 100 ml
Lead Wire 5 Pin 4 Core
AC Cord
Instruction Manual
Warranty Card
Part No.
42557024-25
4345763524
4345663442
WA-75(03U)G
4280400250
4460136841
4280901223
43Q1JDC200
15
INSTRUCTION MANUAL HILIPO CONTOUR
WARRANTY
This product warranty extends to the original consumer /purchaser of the product.
WARRANTY DURATION
This product is warranted to the original consumer for a period of (1) year from the original purchase date.
WARRANTY COVERAGE
This product is warranted against defective materials or workmanship. This warranty ceases if the
product has been damaged by accident, in shipment, unreasonable use, misuse, neglect, improper
service, commercial use, repair by unauthorized personnel or cause not arising out of defect in materials
or workmanship. This warranty does not extend to any units which are used in violation furnished by
manufacturer, or to units which have been altered or modied, or to damage to products or parts there of
which have had the serial number removed, altered or defaced or rendered illegible. The warranty doesn't
cover normal wear & tear or replacement of adaptor, elastic, elec. cord, electrodes & other accessories.
WARRANTY DISCLAIMERS
This warranty is in lieu of all warranties expressed or implied and no representative or person is
authorized to assume for manufacturer/ any other liable in connection with the sale of our products. There
shall be no claims for defects or failure of performance or product failure/ any theory of tort, contract or
commercial law including, but not limited in negligence, gross negligence, strict liability, breach of
warranty and breach of contract. Some states do not allow the exclusion or limitation of implied warranties
or consequential damages, so the above limitations may not apply to you.
Manufacturer is not responsible or liable for indirect special or consequential damages arising out of or in
connection with the use performance of the product or other damage with respect to loss of property or
loss revenues or prot.
WARRANTY PERFORMANCE
During the above one-year warranty period, a product with a defect will be repaired or replaced with a
reconditioned comparable unit at distributor's option when the product is returned to the distributor. The
repaired or replacement product will be in warranty for the balance of the one-year warranty period and an
additional one-month period. No charge will be made for such repair or replacement.
CONSUMER SERVICE
For in warranty service for a product covered under the warranty period, no charge is made for service and
return postage. Please return the product insured, packed with sufcient protection, postage insurance,
prepaid to the address. Customer's duty/brokerage fee, if any, must be paid by the consumer.
OUT OF WARRANTY SERVICE
There will be charges rendered for repairs made to the product after the expiration of the aforesaid one (1)
year warranty period, after purchaser is advised appropriately. The distributor cannot assume
responsibility for loss or damage during shipment. For your protection, carefully pack the product for
shipment and insure it with the carrier. Ensure that you return the unit and accessories related to your
problem and also that you indicate full return address. Also send a copy of sales receipt or other proof of
purchase to determine warranty status. C.O.D. shipments cannot be accepted.
JOHARI DIGITAL HEALTHCARE LTD.
G-582-584, EPIP, BORANADA, JODHPUR
342001 (RAJ.) INDIA
TEL : 0291-3091100 | Email : [email protected]
www.joharidigital.com