INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500...

80
DL-502 DL-503 INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 DL-500 SERIES

Transcript of INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500...

Page 1: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

http://www.topcon.co.jp

GLOBAL GATEWAY http://global.topcon.com/Please see the attached address list or the following website for contact addresses.

DL-502DL-503

INSTRUCTION MANUALDIGITAL LEVEL

FC11808-A021-01

DL-500 SERIES

Page 2: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

This is the mark of the Japan Surveying Instruments Manufacturers Association.

©2010 TOPCON CORPORATIONALL RIGHTS RESERVED

Page 3: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

SURVEYING INSTRUMENTS

Thank you for selecting the Digital Level DL-502/503.• Before using the instrument, please read this operator's manual.• Verify that all equipment is included. See "20.1 Standard Equip-

ment".• DL-502/503 has a function to output data saved in DL-502/503 to

a connected computer. Commands operations from a computercan also be performed. For details, refer to the “DL-502/503 Out-put Format Command Explanations” manual and ask your localdealer.

• The specifications and general appearance of the instrument maybe altered at any time and may differ from those appearing inbrochures and this manual.

• Some of the diagrams in this manual may be simplified for easierunderstanding.

DIGITAL LEVEL

DL-502DL-503

DL-500 SERIES

INSTRUCTION MANUAL

Page 4: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

2

CONTENTS

Read This First

Introduction

Preliminaries

Surveying

ManagingRecorded Data

1. Precautions for Safe Operation ..........................42. Precautions.........................................................73. DL Functions ......................................................9

3.1 Parts of the Instrument and Operation .......93.2 Display......................................................113.3 Operating Keys.........................................153.4 Operating Modes ......................................16

4. Installing and Removing the Battery.................185. Setting Up the Instrument .................................196. Focusing and Sighting ......................................207. Basic Operation ................................................22

7.1 Reading the Staff......................................227.2 Measuring in Status Mode........................24

8. Setting Up Data Storage...................................268.1 JOB Setting ..............................................268.2 Record Conditions ....................................288.3 Double-run Measurement.........................298.4 Flow of Recording Data ............................29

9. Measuring Height Difference ............................3310. Measuring Elevation .........................................3611. Setting Out Height Difference, Distance, and

Elevation...........................................................3911.1 Setting Out Height Difference...................3911.2 Setting Out Distance.................................4111.3 Setting Out Elevation................................42

12. Other Measurement Functions .........................4512.1 Measuring Horizontal Angle .....................4512.2 Using the Instrument as a Standard

Level .........................................................4513. Displaying Recorded Data................................46

13.1 Data Check and Edit.................................4613.2 Number of Recorded Points .....................47

Page 5: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

ManagingRecorded Data

OtherProcedures

SpecificationsRegulations

14. JOB Delete .......................................................4815. Sending Recorded Data ...................................50

15.1 Connecting to a Computer or DataCollector ...................................................50

15.2 Data Output ..............................................5116. Changing the Settings ......................................53

16.1 Measuring Mode.......................................5316.2 Fractional / Decimal representation of

Height Unit................................................5416.3 Communication Parameters .....................5516.4 Auto Power-Off .........................................5516.5 Unit of Measurement ................................55

17. Warnings and Error Messages .........................5718. Charging the Battery.........................................5919. Checks and Adjustments..................................61

19.1 Adjusting the Circular Level......................6119.2 Adjusting the Reticle.................................62

20. Equipment and Accessories .............................6720.1 Standard Equipment.................................6720.2 Optional Accessory...................................6820.3 Type of the staves ....................................69

21. Specifications ...................................................7022. Regulations.......................................................74

Radio Frequency Interference ..........................74CE Conformity Declaration ...............................75For users in California ......................................75

3

Page 6: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

4

Rea

d Th

is F

irst

1. Precautions for Safe Operation

For the safe use of the product and prevention of injury to operatorsand other persons as well as prevention of property damage, itemswhich should be observed are indicated in this operator's manual byWARNING and CAUTION indications.The definitions of the indications are listed below. Be sure youunderstand them before reading the manuals's main text.

Definitions of Indications

• Do not use voltage other than the specified power supply voltage.Fire or electrical shock could result.

• Do not use the unit in areas exposed to high amounts of dust orash, in areas where there is inadequate ventilation, or nearcombustible materials. An explosion could occur.

• Do not perform disassembly or rebuilding. Fire, electric shock orburns could result.

• Never look at the sun through the telescope. Loss of eyesight couldresult.

• Do not look at reflected sunlight from a prism or other reflectingobject through the telescope. Loss of eyesight could result.

• Do not use the carrying case as a footstool. The case is slipperyand unstable so a person could slip and fall off it.

• Do not place the instrument in a case with a damaged catch, belt orhandle. The case or instrument could be dropped and cause injury.

WARNINGIgnoring this indication and making an operationerror could possibly result in death or seriousinjury to the operator.

CAUTIONIgnoring this indication and making an operationerror could possibly result in personal injury orproperty damage.

GeneralWarnings

Cautions

Page 7: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Rea

d Th

is F

irst

• Do not use under thunderous weather conditions. This unit isconductive and if struck by lightning, death or injury could result.

• Handle with care when using near high voltage cables ortransformers. This unit is conductive and contact could result inelectric shock.

• When mounting the instrument to the tripod, tighten the centeringscrew securely. Failure to tighten the screw properly could result inthe instrument falling off the tripod, causing injury.

• Tighten securely the leg fixing screws of the tripod on which theinstrument is mounted. Failure to tighten the screws could result inthe tripod collapsing, causing injury.

• Do not carry the tripod with the tripod shoes pointed at otherpersons. A person could be injured if struck by the tripod shoes.

• Keep hands and feet away from the tripod shoes when fixing thetripod in the ground. A hand or foot stab wound could result.

• Tighten the leg fixing screws securely before carrying the tripod.Failure to tighten the screws could lead to the tripod legs extending,causing injury.

• Use only the specified battery charger to recharge batteries. Otherchargers may be of different voltage rating or polarity, causingsparking which could lead to fire or burns.

• Do not place articles such as clothing on the battery charger whilecharging batteries. Sparks could be induced, leading to fire.

• Do not use damaged power cords, plugs or loose outlets. Fire orelectric shock could result.

• Do not use batteries or the battery charger if wet. Resultantshorting could lead to fire or burns.

StaffWarnings

TripodCautions

Power SupplyWarnings

5

Page 8: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

6

Rea

d Th

is F

irst

• To prevent shorting of the battery in storage, apply insulating tapeor equivalent to the terminals. Otherwise shorting could occurresulting in fire or burns.

• Do not heat or throw batteries into fire. An explosion could occur,resulting in injury.

• Do not connect or disconnect power supply plugs with wet hands.Electric shock could result.

• Do not touch liquid leaking from batteries. Harmful chemicals couldcause burns or blisters

Cautions

Page 9: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Rea

d Th

is F

irst

2. Precautions

Using the Instrument• The DL-502/503 is a precision instrument. Avoid severe shocks or

vibration.• Be careful when removing the instrument from its case.• Do not place the DL-502/503 directly on the ground.• When the operator leaves the DL-502/503, the vinyl cover should

be placed on the instrument.• Never carry the DL-502/503 on the tripod to another site.• Always turn the instrument off and remove the battery before

storing the instrument in its case.• When the instrument is placed in the carrying case, see "20.1

Standard Equipment".• Always wipe off moisture and dirt adhering to the instrument during

survey work. Moisture or dirt on the lens may result in incorrectreadings.

• Consult your local dealer before using the instrument under specialconditions such as long periods of continuous use or high levels ofhumidity. In general, special conditions are treated as being outsidethe scope of the product warranty.

Maintenance• Always clean the instrument before returning it to the case. The

lens requires special care. Dust it off with the lens brush first, toremove tiny particles. Then, after providing a little condensation bybreathing on the lens, wipe it with the supplied cleaning cloth orlens tissue.

• If the display is dirty, carefully wipe it with a soft, dry cloth. To cleanother parts of the instrument or the carrying case, lightly moisten aa soft cloth in a mild detergent solution. Wring out excess wateruntil the cloth is slightly damp, then carefully wipe the surface of theunit. Do not use any organic solvents or alkaline cleaning solutions.

• Store the instrument and accessories in a dry room where thetemperature remains fairly constant.

• If any trouble is found with the screws or optical parts (e.g. lens),contact your local dealer.

7

Page 10: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

8

Rea

d Th

is F

irst

• Always close the case when empty to protect the interior fromhumidity and dust.

• Regular checking and adjustment is recommended to maintaininstrument precision.

Page 11: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Intr

oduc

tion

3. DL Functions

3.1 Parts of the Instrument and Operation

HandleBubble mirrorWhen the instrument is placed high up and cannot be viewedfrom above, you can use the mirror to check the position of thebubble in the tube.Circular levelObjective lensFocusing knobUse this knob to focus on the staff.

• Except where stated, screens and illustrations appearing in thismanual are of DL-502/503.

• In principle, screens used in procedures are based on the factorysetting.

Important:

12

345

9

Page 12: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

1

Intr

oduc

tion

Measure key (appears as in this manual)Starts measurements.(See "3.3 Operating Keys".)Horizontal fine motion knobs (both sides)Use these knobs to finely adjust the instrument's horizontalposition.Data output connectorYou can connect a data collector or computer to this connector.Leveling foot screwBase plateHorizontal circle positioning ringYou can rotate the horizontal scale while the instrument is fixedin position. Use to align benchmarks with '0', etc.Horizontal circleReticle adjusting screw and screw coverUse this screw to mechanically adjust the reticle.Battery coverEyepieceAdjust the reticle focus to suit your eyesight.Keyboard (See "3.3 Operating Keys".)Display (See "3.2 Display".)GunsightUse for coarse adjustment of the orientation of the instrument.

6 Measure

7

8

91011

1213

1415

161718

0

Page 13: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Intr

oduc

tion

3.2 Display

The display includes the following marks which indicate theoperating status and current mode, and help the operator tokeep track of the measurement procedure.

• Point number displayThe next point number to be recorded is displayed.

• Mode display The displayed mark shows the current mode.

: Status mode or Measurement mode: Menu mode: JOB setting mode: Record setting mode: Height difference measurement mode: Elevation measurement mode: Setting out mode: Configuration mode: Data review menu

Version numberCurrently selectedJOB

Measurement

Battery levelconditions

indicator

Mode indicatorAttribute•Measure-

Point numberment step

Measurement values and other data

11

Page 14: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

1

Intr

oduc

tion

• Attribute•Measurement step displayDisplays the backsight and foresight (in Height difference, Settingout, or Measuring elevation modes).

: Backsight: Foresight

Displays the attribute of the recorded measurement value (Heightdifference measurement mode, Elevation measurement mode).

: Backsight point: Foresight point: Intermediate sight: Fixed point: Off

Displays the measurement step (when Adjustment is selected inthe Configuration mode).At position A

: Take a reading on staff a.: Take a reading on staff b.: Take a reading on staff a with the tripod turned 180°.: Take a reading on staff b with the tripod turned 180°.

At position B: Take a reading on staff a.: Take a reading on staff b.: Take a reading on staff a with the tripod turned 180°.: Take a reading on staff b with the tripod turned 180°.

Displays the page number of the active menu (when the Menumode or Configuration mode is selected).

: First page: Second page

• Measuring mode (not displayed on menu screens)Displays the currently selected measuring mode.

: Single measurement: Repeat measurement: Average measurement: Tracking measurement

2

Page 15: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Intr

oduc

tion

• Battery level (not displayed on menu screens)Displays the current power level of the battery.

: Level 3: Full power.

: Level 2: Plenty of power remains.

: Level 1: Half or less power remains.

: Level 0: Little power remains. Charge the battery.

: Low: No power remains (A beep tone sounds and thebattery symbol blinks.) Charge the battery. Operationcannot be performed. After a short time the instrumentautomatically powers off.

• MeasurementsThe following symbols are displayed.

: Staff reading (height): Horizontal distance to staff: Height difference: Elevation

The fractional/decimal display format for measurement value,calculation value and input value depends on the settings inmeasuring mode and fractional/decimal representation of heightunits. (See "16. Changing the Settings".)

• When the fractional/decimal display format is set to "0.0001m" andthe unit of measurement is "m", the display is as follows:

When measuring mode is "Single","Average" or "Repeat"Height: Up to 4 decimalsDistance: Up to 2 decimalsWhen measuring mode is "Tracking"Height: Up to 3 decimalsDistance: Up to 1 decimal

13

Page 16: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

1

Intr

oduc

tion

• When the fractional/decimal display format is set to "0.001m" andthe unit of measurement is "m", the display is as follows:

• When the fractional/decimal display format is set to "0.001ft" andthe unit of measurement is "ft", data is displayed as follows:When measuring mode is "Single", "Average" or "Repeat"Height: Up to 3 decimalsDistance: Up to 1 decimalWhen measuring mode is "Tracking"Height: Up to 2 decimalsDistance: 0 decimal

• When the fractional/decimal display format is set to "0.01ft" and theunit of measurement is "ft", data is displayed as follows:When measuring mode is "Single", "Average" or "Repeat"Height: Up to 2 decimalsDistance: Up to 1 decimalWhen measuring mode is "Tracking"Height: Up to 1 decimalDistance: 0 decimal

• When the fractional/decimal display format is set to "1/8" and theunit of measurement is "inch", the display is as follows:

When measuring mode is "Single","Average" or "Repeat"Height: Up to 3 decimalsDistance: Up to 2 decimalsWhen measuring mode is "Tracking"Height: Up to 2 decimalsDistance: Up to 1 decimal

When measuring mode is "Single","Average" or "Repeat"Height: **-**-*/*Distance: **-**When measuring mode is "Tracking"Height: **-**-*/*Distance: **

4

Page 17: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Intr

oduc

tion

3.3 Operating Keys

Learn main key operations here.

• Power ON/OFF: Power the instrument ON

(hold) + : Power the instrument OFF

• Light up the display: Switch the display backlight ON / OFF

• Measurement start / stop: Start measurement

/ : Stop measurement (in repeat, average or trackingmode)

: Cancel measurement

• Select / cancel (return to former procedure) menus and options/ : Scroll to next position (JOB selection, item selection,

etc.): Accept the option: Enter Menu mode: Return to former procedure or to Status mode

• Value input / cancel: Advance the numeral

Toggle the +/- sign: Change the position of the inverted cursor: Accept the input value

• The fractional/decimal display format for distance measurementsdepends on the setting in measuring mode only.

Note:

Measure

Measure

15

Page 18: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

1

Intr

oduc

tion

3.4 Operating Modes

The DL has a number of functional modes. This sectionshows the screens that can be displayed in each mode.

: Key operation for selecting each menu: Key operation for returning to previous screen

6

Page 19: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Intr

oduc

tion

[Height difference measurement mode]

ESC

Select

[Menu of selected function is displayed]

Select

[Menu of selected function is displayed]

[Elevation measurement mode]

[Setting out .....]

[Config. mode]

(Page 1)

(Page 2)MENU

A B

17

Page 20: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

18

Prel

imin

arie

s

4. Installing and Removing the Battery

Install a fully-charged battery (see "18. Charging the Battery").

1

2

3

Procedure

• Always turn off the power before removing the battery from theinstrument. If the battery is removed when the power is still on,stored data may be lost.

Important:

Page 21: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

19

Prel

imin

arie

s

5. Setting Up the Instrument

1 Set up the tripod.Spread the tripod legs about the same distance apart so that thetripod head is approximately level. Tread the tripod shoes firmly intothe ground.

2 Mount the instrument on the tripod.Hold the instrument on the tripod head and tighten the centeringscrew.

3 Level the instrument.Spherical head tripod: Loosen the centering screw and slide the

instrument across the tripod head until thebubble is centered in the circular level.Tighten the centering screw.

Flat head tripod: Extend or push in the tripod legs until thebubble is centered in the circular level.When the bubble is more or less centered,turn the leveling foot screws until thebubble is exactly centered in the circle.When you turn a screw clockwise, raisingthe instrument, the bubble will move towardthe position of that screw.

Procedure

Page 22: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

2

Prel

imin

arie

s

6. Focusing and Sighting

• Before using the instrumentAdjust the eyepiece to suit your eyesight.

1 Using the gunsight, aim the objective lens toward the staff.

2 Gradually turn the eyepiece outward, stopping just before thereticle cross-lines become blurred.

3 Turn the horizontal fine motion knobs until the staff is nearlycentered in the field of view, then turn the focusing knob to focus onthe staff.

4 Looking through the telescope, shift your eyes slightly up and downand to each side.

5 If the staff and reticle show no deviation, the instrument is ready foruse. If the staff and reticle deviate, return to step 2.

Procedure

• If deviation occurs at step 5, errors will occur when takingmeasurements. Always make sure the instrument is correctlyfocused.

Important:

0

Page 23: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Prel

imin

arie

s

• Focusing when taking measurements

1 Using the gunsight, aim the objective lens toward the staff.

2 Turn the horizontal fine motion knobs until the staff is nearlycentered in the field of view, then turn the focusing knob to focus onthe staff.

Procedure

• If the staff barcodes are out of focus, they will not be readableand measurements cannot be taken. Make sure they arecorrectly focused.

Important:

21

Page 24: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

2

Surv

eyin

g

7. Basic Operation

7.1 Reading the Staff

Simply focus on the RAB* code for an automatic reading ofthe staff. The following explains how to read the RAB codeof the staff.* : RAB code (Random Bi-directional code) is a coded staff

used with TOPCON DL-500 line of digital levels.

(Continued on next page)

• Set up the staff in an area free of obstacles.Avoid placing the staff next to mirror-like surfaces. The effect ofstrong light could make measurement impossible.

• Support the staff so that it is perpendicular, checking the circularbubble scope on the staff. If the staff is tilting, height and distancemeasurements will be incorrect.

• If the surface is catching the light, turn it just enough to stop thereflection.

• Make sure shadows are not cast on the staff as this could makemeasurement impossible.

• When holding the staff during measurement, make sure yourhand does not cover the RAB code.

• If dark locations make measurement difficult, shine a flashlight onthe staff. Stand at a distance so that the beam shines evenlyover the length of the staff.

Important:

2

Page 25: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

23

(Continued from previous page)

• Setting up the staff

1 Connect the staffs correctly by making sure the numbers on thenumeric scale side of the staffs run in unbroken order.

2 Set the foot plate on the ground so that the staff will not sink.

3 Keeping an eye on the circular bubble scope on the staff, set thestaff in the foot plate so that it stands up straight.

4 Turn the barcode scale toward the instrument.

• Measuring the height from a ceiling

• If waterdrops or dirt adhere to the barcode, measurement may beimpossible. Wipe the staff clean with a soft cloth.

• Clean the staff if grit or dirt gets stuck between the sections. If thestaff is dirty, measurements will not be very accurate.

• Avoid scratching or soiling the barcode surface as this couldmake measurement impossible. Store and carry the staff insideits case.

• If the BGS series staff is used for leveling, and the heightdifference and temperature difference are much larger thannormal, temperature variations may cause the staff to expand orcontract and cause differences in relative height measurements.DL-502/503 reads in measurements up to 0.1mm and minordeviations in the accuracy of the staff will adversely affectaccuracy. To obtain high accuracy measurements, it is importantto perform temperature corrections for the staff. (See the Notebelow for details.)

Procedure

Page 26: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

2

Surv

eyin

g

7.2 Measuring in Status Mode

In status mode you can sight point A, take the staff reading(Rh), and measure the horizontal distance (Hd) to the staff.

Formula for correcting expansion and contraction of the staff due to temperature changes

C={C0+(T-T0)x }x h

C: Staff correction valueC0: Scale factor T: Measured temperature during observation (average temperature during measurement of known site, intermediate site, new site)T0: Reference temperature of 20 C

: Line expansion coefficient

(BGS series : 20x10-6 1/ C)

h: Height difference

Δ α Δ

Δ

°

α

°

Δ

Note:

4

Page 27: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

The procedure below is for taking single measurements. Forrepeat measurements, see the notes.

1 Turn the power switch on.2 Focus on the staff and press .

Operation starts and the display blinkswhile measurements are being taken.When measurement is completed,the staff readings (Rh) and horizontaldistance (Hd) are displayed.

• During measurement, if direct sunlight or strong light enters theeyepiece and measurement cannot be performed,"Measurement error" or "Too bright" is displayed (see "17.Warnings and Error Messages"). Shield the eyepiece from thelight source using your body or cover the eyepiece with yourhand and resume measurement.

• If the DL-502/503 is subjected to shocks or vibration during use,measurement may be impossible. Resume measurement duringmore stable conditions.

Important:

Procedure

Measure

• In Repeat, Average, or Tracking mode:Step 2: Values are renewed at each measurement.

Press or to stop the reading.Press to cancel the reading.

Measure

Note:

25

Page 28: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

2

Surv

eyin

g

8. Setting Up Data Storage

Data can be stored in Height difference measurement mode orElevation measurement mode. JOB setting mode and record settingmode must be set up before data can be recorded.

8.1 JOB Setting

Set the JOB containing the measurement data to be recorded.Select from *JOB01 to JOB20.

JOB setting mode Record setting mode

• *: Factory setting• Settings are saved even after the instrument is turned off. • Up to 2000 points can be registered. If 2000 points have been

already recorded, a beep tone sounds twice and the number offree points remaining is displayed as "0". Measurement resultsare not recorded. Press any button to return to the previousscreen.

• See "15.2 Data Output" and "14. JOB Delete" for how to "Output"and "Delete" in the JOB setting mode.

• See "13. Displaying Recorded Data" for how to use "Review" and"Memory" in the Record setting mode.

Notes:

• Between 1 and 12 characters can be set for the JOB name.• If measurement data has already been saved in the selected

JOB, the unit of measurement (m or ft) cannot be changed. Thesame unit of data will be applied in the future to data that is savedto the same JOB.

• JOB names already used cannot be set.

Notes:

6

Page 29: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

• JOB Selection

• Changing the JOB name

1 In the menu mode, select "JOB," andthen select "Select."The currently selected JOB andnumber of data recorded in the JOBare displayed.

2 Select the JOB you will store the datato.

3 Press to confirm the selectedJOB.

1 In menu mode, select "JOB" andthen "Edit."The currently selected JOB name isdisplayed and can now be edited. The characters that can be input areshown below. Each time ispressed, the cursor jumps to the firstcharacter of each row shown below.

Procedure

• JOB Quick AccessStep 2: When JOB numbers 1 to 10 are displayed, press

to jump to JOB number 11. When JOB numbers 11 to 20are displayed, press to jump back to JOB number1.

Note:

Procedure

27

Page 30: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

2

Surv

eyin

g

8.2 Record Conditions

Select the method for recording measurement data.In the menu mode, select "REC," and then "Cond."* Manual: When measurement is completed, check and

record the dataAuto: Data is automatically recorded for foresight point

measurements (check and record backsightpoint measurements manually)

Off: Data cannot be recorded.

0 1 2 3 4 5 6 7 8 9ABCDEFGHIJKLMNOPQRSTU V W X Y Z . + -

For example, to display the word AT.

2 Press four times to display "A."

3 Press to move the cursor to thenext character.

4 Press five times to display "T."

5 When the word has been input, press to record the JOB name.

8

Page 31: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

8.3 Double-run Measurement

You can set single-run or double-run measurement data asadditional information. When data is sent, you candistinguish single-run from double-run measurement data.In menu mode, select "REC" and then "Line."* Go: Record sent data

Return: Record returned data

8.4 Flow of Recording Data

The following explains the flow of recording measurementdata. When using the numerical scale side of the staff andnot the RAB code, manually input the measurement data.

A detailed explanation is provided below for items indicatedby a *.

Note:When "Return" is selected, "*" is displayed in front of measurement value Rh.

29

Page 32: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

3

Surv

eyin

g

The following procedure is an example of measurement in heightdifference measurement mode.

• Setting the point number

1 Press when measuring thebacksight point.The point number can now be set.

Set the backsight point number*

Measure the backsightpoint

Check and record the measurement results

Set attributes of foresight point*

Set the point number of the foresight point*

Measure (foresight) point

Check and record the measurement results

Move the instrument point

Measure previous point as backsight point

Measure next foresight point

Procedure

0

Page 33: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

• Setting attribute (only foresight)

2 Set the point number.

3 Press to confirm the pointnumber.

1 Press when measuring theforesight point.The attribute can now be set.

2 Set the attribute.Each time or is pressed: IS(intermediate sight) FIX (fixedpoint) Off FS (foresight) IS(intermediate sight)

Advancing the point number If the point number is not set, data is recorded using theautomatically set number in the currently selected JOB. Check themeasurement results together with the point number. Pointnumber is displayed as follows:• First record after power is switched ON • No data stored in JOB...

0001• First record after power is switched ON • Data stored in JOB...

point number of last measurement point• Second or later record after power is switched ON • turning

point...point number of last measurement point• Second or later record after power is switched ON • No turning

point...point number of last measurement point +1

Notes:

Procedure

31

Page 34: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

3

Surv

eyin

g

• Inputting measurement data (measure the point using thenumerical scale side of the staff)

3 Press to confirm the selectedattribute.The point number can now be set.(See "Setting the point number".)

1 Focus the DL-502/503 on thenumerical scale side of the staff andmeasure the backsight point.

2 Press .Measurement data can now be inputmanually.

3 Input the measurement value foundin step 1.

4 Check the point number and press"Yes" to record the selected data.

5 Measure the next point.

If the attribute is not set, a point other than the backsight point isrecorded as the foresight point.

Note:

Procedure

2

Page 35: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

9. Measuring Height Difference

You can measure the height difference ΔH between the backsight (pointA) and foresight (point B).

The procedure below is for taking single measurementswhen "manual" is selected in the Record conditions menu.

1 Set up the instrument midway betweenpoints A and B.

2 In menu mode, select "Ht-diff".

3 Measure the backsight.

4 Select "Yes" to accept the pointnumber attribute and measurementvalue.

The result is saved and the numberof points that can be recorded inavailable memory is displayed.

ΔH

• When moving the instrument to a new position (step 8 below),press "Yes" to save the turning point before switching off thepower.

Important:

Procedure

33

Page 36: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

3

Surv

eyin

g

5 Measure the foresight.The instrument calculates the heightdifference ΔH relative to thebacksight, and displays the result.

6 Select "Yes" to accept the pointnumber, attribute and measurementvalue.The result is saved.

7 Press .A message asks whether you want tochange the instrument position.

8 If moving the instrument, select "Yes".In step 5, the measured foresight isrecorded as turning point (TP) heightdifference.

9 Transfer to the next instrument positionand repeat the measurements fromstep 3.The height difference measured at step5 is displayed as the height differenceof the backsight (TP).

4

Page 37: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

• Point number inputStep 3: Press to ready the instrument for point

number input.Step 5: Press twice to ready the instrument for

point number input.(See "8.4 Flow of Recording Data".)

• Attribute settingStep 5: Press to ready the instrument for attribute

setting. (See "8.4 Flow of Recording Data".)• Go and Return setting

Step 3: Press to display the Go and Return SettingScreen. (See "8.3 Double-run Measurement".)

• Reviewing stored dataSteps 3 and 5: Press to display the contents of the

selected JOB. (See "13.1 Data Check and Edit".)• Manually inputting measurement data

Steps 3 and 5: Press . Measurement data can now be inputmanually. (See "8.4 Flow of Recording Data".)

Notes:

35

Page 38: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

3

Surv

eyin

g

10. Measuring Elevation

From a known elevation (point A), you can measure the elevation (HA+ ΔH) of a specified ground point (point B).

The procedure below is for taking single measurementswhen "Manual" is selected in the Record conditions menu.

1 Set up the instrument between pointsA and B.

2 In menu mode, select "Elev.".

3 Input the backsight elevation.

4 Measure the backsight.

• When moving the instrument to a new position (step 9 below),press "Yes" to save the Turning Point before switching off thepower.

Important:

Procedure

6

Page 39: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

5 Select "Yes" to accept the pointnumber and measurement value.The result is saved and the numberof points that can be recorded inavailable memory is displayed.

6 Measure the foresight.The instrument calculates the foresightelevation (Z), and displays the result.

7 Select "Yes" to accept the pointnumber, attribute and measurementvalue.The result is saved.

8 Press .A message asks whether you want tochange the instrument position.

9 If moving the instrument, select"Yes".In step 6, the measured foresight isrecorded as turning point (TP)elevation.

10 Transfer to the next instrument positionand repeat the measurements fromstep 3.The elevation measured at step 6 ismeasured as the elevation of thebacksight (TP).

37

Page 40: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

3

Surv

eyin

g

• Point number inputStep 4: Press to ready the instrument for point

number input.Step 6: Press twice to ready the instrument for

point number input.(See "8.4 Flow of Recording Data".)

• Attribute settingStep 6: Press to ready the instrument for attribute

setting. (See "8.4 Flow of Recording Data".)• Go and Return setting

Step 4: Press to display the Go and Return SettingScreen. (See "8.3 Double-run Measurement".)

• Storing backsight elevationSteps 3 and 10: Even after power off, backsight elevation is

stored or turning point is stored as the nextbacksight elevation. Since this value is thesame as the value in the setting out elevationmode, the backsight elevation is stored towhichever mode is set last. (See "11.3 SettingOut Elevation".)

• Reviewing stored dataSteps 4 and 6: Press to display the contents of the

selected JOB. (See "13.1 Data Check and Edit".)• Manually inputting measurement data

Steps 4 and 6: Press . Measurement data can now beinput manually. (See "8.4 Flow of RecordingData".)

Notes:

8

Page 41: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

11. Setting Out Height Difference, Distance, and Elevation

You can locate ground points that correspond to entered numericaldata. The Set-Out menu provides three modes - height difference,distance, and elevation.

11.1 Setting Out Height Difference

By entering the height difference (ΔH) from a benchmark(point A), you can find a ground point (point B) at a specifiedheight difference from the benchmark.

The procedure below is for taking single measurements.

1 Set up the instrument between pointsA and B.

2 In menu mode, select "Set-out", thenselect "Ht-diff".

3 Input the height difference value thatyou want to stake out.

Procedure

39

Page 42: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

4

Surv

eyin

g

4 Measure the backsight.The instrument takes the backsightreading and displays the measure-ment.

5 Select "Yes" to accept the value.

6 Measure the foresight.The instrument calculates the differ-ence between the measurement andthe input value, and displays theresult.

7 Move the staff by the amount shownon the screen, then take anotherforesight reading.If "Fill" is displayed, move the staffupward.If "Cut" is displayed, move the staffdownward.When the display shows '0', you havefound the specified ground point.

8 Press or .Height difference set-out is completed.Set out the next ground point.

• When in this menu and setting-out has already been taken (forthe second or subsequent reading):Step 4: The previous backsight measurement will be displayed

and the program skips to step 5.

• Storing setting out height difference:Step 3: Even after power off, the height difference is stored.

Notes:

0

Page 43: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

11.2 Setting Out Distance

By entering the distance (Hd) from a benchmark (point A),you can find a ground point (point B) at a specified distancefrom the benchmark.

The procedure below is for taking single measurements.

1 Set up the instrument at point A.

2 In menu mode, select "Set-out", thenselect "Dist.".

3 Input the distance that you want tostake out.

4 Measure the foresight.The instrument calculates the differ-ence between the measurement andthe input value, and displays theresult.

Procedure

41

Page 44: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

4

Surv

eyin

g

11.3 Setting Out Elevation

By entering the elevation (HA + ΔH) from a known benchmark(point A), you can find a ground point (point B) at a specifiedelevation.

The procedure below is for taking single measurements.

5 Move the staff by the amount shownon the screen, then take anotherforesight reading.If "Out" is displayed, move the staffbackward.If "In" is displayed, move the staffforward.When the display shows '0', you havefound the specified ground point.

6 Press or .Distance set-out is completed. Setout the next ground point.

• Storing setting out distanceStep 3: Even after power off, distance is stored.

Note:

2

Page 45: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Surv

eyin

g

1 Set up the instrument midwaybetween points A and B.

2 In menu mode, select "Set-out", thenselect "Elev.".

3 Input the backsight elevation.

4 Measure the backsight.The instrument takes the backsightreading and displays the measurement.

5 Select "Yes" to accept the value.

6 Input the elevation that you want tostake out.

7 Measure the foresight.The instrument calculates the differ-ence between the measurement andthe input value, and displays the result.

8 Move the staff by the amount shownon the screen, then take anotherforesight reading.If "Fill" is displayed, move the staffupward.If "Cut" is displayed, move the staffdownward.When the display shows '0', you havefound the specified ground point.

Procedure

43

Page 46: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

4

Surv

eyin

g

9 Press or .Elevation set-out is completed. Setout the next ground point.

• When in this menu and setting-out has already been taken (forthe second or subsequent reading):Step 4: The previous backsight measurement will be displayed

and the program skips to step 5.

• Storing backsight elevation:Step 3: Even after power off, backsight elevation is stored.

Since this value is the same as the value in theelevation measurement mode, the backsight elevationis stored to whichever mode is set last. (See "10.Measuring Elevation".)

• Storing setting out elevation

Step 6: Even after power off, elevation is stored.

Notes:

4

Page 47: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

45

Surv

eyin

g

12. Other Measurement Functions

12.1 Measuring Horizontal Angle

You can measure the horizontal angle between point A andpoint B by using the horizontal circle.

12.2 Using the Instrument as a Standard Level

By using the numeric scale side of the staff, you can use theDL-502/503 as a standard level. Simply focus on the staffand read the scale.

In the Height difference measurement mode and Elevationmeasurement mode, the sighted value can be manuallyinput in the currently selected JOB. (See "8.4 Flow ofRecording Data".)

Page 48: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

4

Man

agin

g R

ecor

ded

Dat

a

13. Displaying Recorded Data

Data recorded in Height difference measurement mode or Elevationmeasurement mode can be edited.Use the Record Setting Mode to check data and display the number ofrecorded points.

13.1 Data Check and Edit

Check the contents saved in the currently selected JOB.Attributes can be changed.

1 In menu mode, select "REC" andthen select "Review."The last recorded data in thecurrently selected JOB is displayed.

2 Display the data that you want toreview.Press to display the previouslydisplayed data.

• Attributes can be changed in the following order only: BS(backsight point) FS (foresight point) IS (intermediate sight)

FIX (fixed point) Off DEL (delete). (Example: Datarecorded as IS (intermediate sight) can be changed to FIX (fixedpoint), Off or DEL (delete), but not to BS (backsight point) or FS(foresight point).

• Point number and measurement results cannot be edited.

Important:

Procedure

6

Page 49: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Man

agin

g R

ecor

ded

Dat

a

13.2 Number of Recorded Points

In the menu mode, select "REC," and then "Memory." Thenumber of points (up to 2000) that can be recorded isdisplayed.

3 Press .The attributes can now be changed.

4 Display the attribute you want tochange.

5 Press to confirm the selectedattribute.

• "DEL" setting and Number of points that can be recordedIf the DEL attribute is selected for recorded data, the data is notdisplayed. Setting DEL does not delete data from memory, so thenumber of points that can be stored in free memory does notincrease. When a JOB is deleted, all data with the DEL attributesrecorded in other JOBs is also deleted.

• Double-run MeasurementWhen "Return" is selected, "*" appears in front of measurementvalue Rh.

Notes:

• You can reach here also by pressing and then instatus mode.

Note:

47

Page 50: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

4

Man

agin

g R

ecor

ded

Dat

a

14. JOB Delete

Delete the JOB and the contents of the JOB.Carry out JOB deletion in the JOB setting mode. (JOBs cannot bedeleted when the battery is LOW.)

1 In menu mode, select "JOB" andthen "Delete."The currently selected JOB andnumber of data recorded in the JOBare displayed.

2 Display the JOB you want to delete.

3 Press , and then select "Yes."The selected JOB and contents ofthe JOB are deleted.

• JOBs that cannot be output (indicated by * next to JOB) cannotbe deleted.

Important:

Procedure

8

Page 51: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Man

agin

g R

ecor

ded

Dat

a

• JOB Quick AccessStep 2: When JOB numbers 1 to 10 are displayed, press to

jump to JOB number 11. When JOB numbers 11 to 20 aredisplayed, press to jump back to JOB number 1.

• JOB nameStep 3: After the JOB is deleted, the default JOB name set at

the factory is displayed: JOB01 to JOB20.

• Number of points that can be recordedWhen a JOB is deleted, data with the DEL attributes recorded inother JOBs is also deleted, and the value indicating the numberof points that can be stored in free memory increases.

Notes:

49

Page 52: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

5

Man

agin

g R

ecor

ded

Dat

a

15. Sending Recorded Data

Connect DL-502/503 and a computer/a data collector. Recorded data canbe sent to a computer or a data collector.Commands sent from a computer or the data collector instruct the DL-502/503 to carry out measurement, and the measurement results areoutput.

15.1 Connecting to a Computer or Data Collector

Use the dedicated communication cable to connect the DL-502/503 to the data collector or a computer.

• Communication cable

If using a data collector, use the cable supplied with the datacollector.

Computer Cable NotesIBM PC/AT orcompatible

DOC26 Length: 2mPin Numbers and signal levels:

RS-232C compatibleD-sub connector:

DOC26: 25 pins (female)DOC27: 9 pins (female)

DOC27F-4F-24

Other personalcomputers

DOC1 No connector for attachment toa computer.

• The DL-502/503 accepts commands only when in status mode ormenu mode. Received commands are not executed in any other

Important:

0

Page 53: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Man

agin

g R

ecor

ded

Dat

a

• Pin assignments of the data output connector

15.2 Data Output

The contents of a JOB can be output to a computer in CSVor SDR2X format.

Pin No. Signal1 SG (GND)2 NC (unused)3 SD (TXD)4 RD (RXD)5 Power source (output)6 Reserved (must not be used)

1 Use a cable to connect the DL-502/503 to a computer. ("15.1 Connectingto a Computer or Data Collector")

2 In menu mode, select "JOB" andthen "Output." The currently selectedJOB and recorded point numbers aredisplayed.

3 Select the JOB you wish to send.

• Data recorded in a JOB that has not been sent is indicated by anasterisk (*).

Important:

Procedure

51

Page 54: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

5

Man

agin

g R

ecor

ded

Dat

a

4 Select the data output format.Data is output. When data output iscompleted, the DL-502/503 returns toJOB setting mode.

• JOB Quick AccessStep 2: When JOB numbers 01 to 10 are displayed, press

to jump to JOB number 11. When numbers 11 to20 are displayed, press to jump to JOB number1.

Step 4: Press to display the communication conditionssetting screen.

• Data output format/command operationsFor details, refer to the "DL-502/503 Output Format•CommandExplanations" manual and ask your local dealer.

Note:

2

Page 55: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

16. Changing the Settings

You can change settings such as the measuring mode and the numberof decimals in displayed data.When you select "Config." in menu mode, the two-page configurationmenu is displayed.

16.1 Measuring Mode

You can select any of the following measuring modes.* Single: The instrument automatically terminates fine

measurement after taking one reading.Repeat: The instrument repeats fine measurements

until the operator presses or .Average: Displays the average value calculated from the

number of times fine measurement is repeated.

Page 1• Meas. (measuring mode)• Display (fractional/decimal

representation of height units)• Adjust (checks and adjustment)• RS-232C (communication

parameters)

Page 2• Auto-off (auto power-off)• Unit (unit of measurement)

• Press to toggle between the pages.• Asterisks (*) indicate factory settings.• Settings are kept in memory after power-off.• "19.2 Adjusting the Reticle" for the check and adjustment

procedure.

Notes:

Measure

53

Page 56: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

5

Oth

er P

roce

dure

s

(Repeat default setting: 5 times, Repeat settingrange: 2 to 9 times.)

Tracking: The instrument repeats coarse measurementsuntil the operator presses or .

16.2 Fractional/Decimal Representation of HeightUnits

You can set the fractional/decimal display format fordisplaying height values.The following options are available when using "m" as the unit:* 0.0001m: Up to 4 decimals (when measuring mode is

"single", "repeat" or "average")/Up to 3 decimals(when measuring mode is "tracking")

0.001m: Up to 3 decimals ("single", "repeat" or "average)"/Up to 2 decimals ("tracking").

The following options are available when using "ft" as the unit:* 0.001ft: Up to 3 decimals (when measuring mode is

"single", "repeat" or "average")/Up to 2decimals (when measuring mode is "tracking").

0.01ft: Up to 2 decimals ("single", "repeat" or "average")/Up to 1 decimal ("tracking").

Only the following option is available when using "inch" asthe unit:

1/8: **-**-*/*

Measure

• When is pressed in Set-out mode, the Measurementconditions setting screen can be displayed.

Note:

The fractional/decimal display format for distance values dependson the settings only in measuring mode.(See "3.2 Display".)

Note:

4

Page 57: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

16.3 Communication Parameters

You can select the communication parameters forconnecting a data collector or a computer.The baud rate and parity settings can be set and modified.

• Baud rate: *1200 bps / 2400 bps / 4800 bps /9600 bps / 19200 bps / 38400 bps

• Parity: *None / Odd / Even

16.4 Auto Power-Off

You can enable or disable the auto power-off function.* On(30min): The instrument powers off automatically 30

minutes after the last key operation.Off: The auto power-off function is disabled.

16.5 Unit of Measurement

You can select the display unit to be used.* m

ftinch

• Outputting start code and end code (CSV format)Press to display the setting screen for outputting start andend codes.

Yes: During data output, outputs start code (STX) and endcode (ETX).

* No: Outputs text data only.

Note:

55

Page 58: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

5

Oth

er P

roce

dure

s

• If measurement data has already been saved in the selectedJOB, the unit of measurement cannot be changed.

• "Inch" here means "fraction of an inch", "fraction of an inch" is theunit used in the United States and expressed like the followingexample.

Note:

6

Page 59: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

17. Warnings and Error Messages

The table below shows the warnings and error messages displayed bythe DL-502/503 and describes the cause of each warning or errormessage.

Error Message Coded Message MeaningE400E401E405E406

• System error due to a faultin the instrument. Contactyour local dealer.

E410E411E412E413E414E415E416E417E418E419E420E421E422E423E424E425E426E427E428E429

• An object other than thestaff is being sighted.

• The staff is out of focus.• The staff is partly unread-

able because obscuredby an obstacle or dam-aged.

• The staff is too close ortoo far away.

• A shadow is falling onpart of the staff.

• The staff was incorrectlysighted.

• Light is coming into theeyepiece.Use your hand or body toshield eyepiece from lightsource.

57

Page 60: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

5

Oth

er P

roce

dure

s

E430E433

• Too bright.• The brightness level sud-

denly altered during themeasurement.

• Something is shiningnearby or at back of thestaff.

• Light is coming into theeyepiece.

• Use your hand or body toshield eyepiece from lightsource.

E431 • Something obscured thestaff or the brightnesslevel suddenly altered dur-ing the measurement.

E432 • Too dark.• The brightness level sud-

denly altered during themeasurement.

E440 • The instrument is subjectto excessive vibrations orhot conditions are pro-ducing shimmer.

Error Message Coded Message Meaning

Coded messages are not displayed on DL-502/503 display.Note:

8

Page 61: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

18. Charging the Battery

1 Connect the power cable to the CDC68 charger and plug thecharger into the wall outlet.

2 Mount the battery (BDC46B) in the charger (CDC68) matching thegroove on the battery with the guides on the charger.When charging starts, the lamp starts blinking.

• Do not short circuit. Heat or ignition could result.• Batteries cannot be charged, even when the charging lamp is

flashing, when the temperature is outside the chargingtemperature range.

• Do not leave the battery anywhere exposed to hightemperatures. Battery life may be reduced.

• Charge the battery once a month to maintain its quality when notin use for long periods.

• Do not charge the battery just after charging is completed.Battery performance may decline.

• Do not use to charge batteries other than those specified.• If you allow the battery level to get too low, the battery may not be

rechargeable or operating time may decline. Keep the batteryalways charged.

• The charger will get rather hot while in use. This is normal.

Important:

Procedure

59

Page 62: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

6

Oth

er P

roce

dure

s

3 Charging takes approximately 2.5 hours.The lamp lights when charging is finished.

4 Remove the battery and unplug the charger.

• Slots 1 and 2• Step 2: The charger starts charging the battery mounted

first. If you place two batteries in the charger, thebattery in slot 1 is charged first, and then thebattery in slot 2.

• Charging lamp• Steps 2 and 3: The charging lamp is off when

•The charger is outside the charging temperaturerange.

•The battery is mounted incorrectly.If the lamp is still off after the charger falls withinits charging temperature range and the battery ismounted again, contact your local dealer.

Notes:

0

Page 63: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

19. Checks and Adjustments

Always check and adjust before use to ensure accuratemeasurements.Make sure the instrument is securely set up and stable beforeperforming checks and adjustments.

19.1 Adjusting the Circular Level

Check that the bubble remains centered in the circular level. Adjust if the bubble shifts position.

1 Adjust the leveling foot screws untilthe bubble is centered in the circle.

2 Turn the instrument 180°.The bubble should not shift from thecenter. If the bubble does move,adjust as follows:

3 Compensate for one-half of the shiftby adjusting the leveling foot screws

4 Eliminate the remaining shift byturning the circular level adjustingscrews with the hexagonal wrenchuntil the bubble is centered.

Procedure

Adjust with the level adjusting screw

Adjusting screws

61

Page 64: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

6

Oth

er P

roce

dure

s

19.2 Adjusting the Reticle

The reticle cross-lines can be corrected if out of adjustment.While reading the staff RAB-code, adjust the reticle bycorrecting the reference value of the CCD line sensor andthen make mechanical adjustments to the instrument.

• Correcting the reference value of the CCD line sensorAs described in the following procedure, high accuracyreadings are obtained by turning the tripod and taking repeatreadings of the staff. For less accurate readings, see Notesfor checking the reticle without turning the tripod.

5 Turn the instrument 180°.If the bubble stays in the center,adjustment is completed. If thebubble moves, repeat steps 3 and 4.

1 In menu mode, select "Config", thenin page 1 of the Config. menu, select"Adjust".

2 Place staffs a and b approximately30m apart and set the instrumenthalfway between the staffs (positionA).

3 Press .

4 Measure staff a.

5 Select "Yes" to accept the value.

6 Measure staff b.

Procedure

2

Page 65: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

7 Select "Yes" to accept the value.

8 Select "Yes".

9 Turn the tripod 180°.

10 Repeat steps 4 through 6, sighting thetwo staffs and taking the readings.

11 Select "Yes" to accept the value.

12 Move the instrument to a positionapproximately 3m from staff a alonga straight line joining staffs a and b.The new position is B.

13 Press .

14 Repeat steps 4 through 11, sightingthe two staffs and taking the readings.If you turned the tripod at step 8, adiagram of the tripod positions will bedisplayed. Turn the tripod again.

15 Check the difference between theresults and decide whether correctingthe reference value of the sensor isrequired.If the difference is 3mm or less, noadjustment is necessary.If the difference exceeds the 3mmpermissible range, adjustment isnecessary.

63

Page 66: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

6

Oth

er P

roce

dure

s

• Mechanical adjustment

If correcting the reference value is not necessary:16 Select "No".

17 Select "Yes" to exit from the Adjustmenu.

If correcting the reference value is required:16 Select "Yes".

The instrument calculates and recordsthe required reticle adjustment fromthe measurement results, and thenreturns to the menu selection.

17 Repeat steps 1 through 15. Makesure that the difference between theresults is within 3mm.

1 Sight the barcode face of staff b fromposition B and measure with theinstrument.

2 Sight the scale face of staff b fromposition B and take a visual reading.

3 If the difference between the mea-surements taken at steps 1 and 2 is2mm or more, adjust the cross-lineas described below.If the difference is less than 2mm, thefollowing steps are not necessary.

4

Page 67: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

4 Remove the adjusting screw coverand insert a hexagonal wrench (M3)in the adjusting screw.

5 Turn the adjusting screw, then repealsteps 1 and 2. Adjust so that thedifference between the two measure-ments is less than 2mm.If the measurement at step 2 is largerthan the measurement at step 1, lowerthe cross-line by slightly loosening theadjusting screw.If the measurement at step 2 issmaller than the measurement at step1, raise the cross-line by slightlytightening the adjusting screw.

6 Replace the adjusting screw cover.

65

Page 68: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

6

Oth

er P

roce

dure

s

• Saving measurement values during correcting the referencevalue of the sensor and power off

• Steps 9, 12 and 14:

"Data keep" screen asks whether or not youwant to save the measurement values duringsetting internal constants.Select "Yes" to save measurement valuesand turn power off. When power is turned onagain and page 1 of the Config. menu isselected, Screen Status at last power off isdisplayed.Select "No" to cancel measurement valuesand turn power off.

• Difference calculations:• Step 15: If the tripod is turned and repeat measurements taken:

Value at position A = {[(1st reading on staff a) + (1streading on staff b)] + [(2ndreading on staff a) – (2nd readingon staff b)]} / 2

Value at position B = {[(1st reading on staff a) + (1streading on staff b)] + [(2ndreading on staff a) – (2nd readingon staff b)]} / 2

Difference = absolute value of [(value at position A) –(value at position B)]

If the tripod is not turned and only one set ofmeasurements are taken:Value at position A = [(reading on staff a) – (reading on

staff b)]Value at position B = [(reading on staff a) – (reading on

staff b)]Difference = absolute value of [(value at position A) –

(value at position B)]

Notes:

6

Page 69: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

20. Equipment and Accessories

20.1 Standard Equipment

Before using your DL-502/503, first make sure that all thefollow-ing products were supplied.

• Layout Plan

DL-502/503 ....................................................................1 Battery (BDC46B) ..........................................................1 Charger (CDC68)...........................................................1 Power cable (EDC113A/113B/113C)..............................1 Hexagonal wrench M2.5 (for circular level, reticle) ........1 Dust cover......................................................................1 Cleaning cloth ................................................................1 Operator's manual .........................................................1 Carrying case.................................................................1The optional accessory can also be placed in the carrying case. Diagonal eyepiece (DE23) .............................................1

123456789

10

67

Page 70: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

6

Oth

er P

roce

dure

s

20.2 Optional Accessory

• Diagonal eyepiece (DE23)The diagonal eyepiece is useful for taking measurements inconfined spaces.First remove the standard DL-502/503 eyepiece by turning itcounter-clockwise. Then, screw the diagonal eyepiece inplace of the standard eyepiece.

8

Page 71: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Oth

er P

roce

dure

s

20.3 Type of the staves

• Type of the staves

Name Material Length/Front/Reverse Feature

BIS20 Invar 2.0m(6.6ft)Front: RAB code

ISO 12858-1:1999 compatible

BIS30 Invar 3.038m(9.8ft)Front: RAB code

ISO 12858-1:1999 compatible

BGS40 Glass fiber 4.08m(3 sections)Front: RAB codeReverse: graduated

With handle

BGS50 Glass fiber 5.09m(4 sections)Front: RAB codeReverse: graduated

With handle

BGS50G Glass fiber 5.09m(4 sections)Front: RAB codeReverse: graduated

With handle

(Unit : Feet)

BAS55 Aluminum 5.0m(5 sections)Front: RAB codeReverse: graduated

BRS55 Aluminum 5.0m (5 sections)Front:RAB codeReverse:graduatedon reflective surface

Distances can bemeasured with TotalStation by using thereverse side of thereflective sheets.(Applies only to instruments thatcan measure in thesheet mode.)

69

Page 72: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

7

Spec

ifica

tions

21. Specifications

Except where stated, the following specifications apply to all DLs.

TelescopeLength 260 mmObjective aperture: DL-502: Ø45mm

DL-503: Ø36mmMagnification: DL-502: 32x

DL-503: 28xImage: ErectResolving power: DL-502: 3″

DL-503: 3.5″Field of view: 1°20′Minimum focus: 1.5m (5.0 ft)Stadia ratio: 1:100Stadia additive constant: 0

StavesInvar staff

BIS20: 85mm(W)x40mm(D)x2000mm(H){3.4in.(W)x1.6in.(D)x6.6ft(H)}4.3kg(9.5lb.) (a staff) 17.1kg (37.7lb.)(two staffs and case)

BIS30: 85mm(W)x40mm(D)x3038mm(H){3.4in.(W)x1.6in.(D)x10.0ft(H)} 5.5kg(12.2lb.) (a staff) 23.4kg (51.6lb.) (two staffs and case)

The coefficient of linear expansion : α=1x10-6 [1/°C]

0

Page 73: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Spec

ifica

tions

Glass fiber staffBGS40: 58mm(W)x28mm(D)x4080mm(H)

(3sections){2.3in.(W)x1.1in.(D)x13.3ft(H)}2.4kg(5.3lb.) (a staff) 3.0kg (6.6lb.) (a staff and case)

BGS50/50G: 58mm(W)x28mm(D)x5090mm(H) (4sections){2.3in.(W)x1.1in.(D)x16.7ft(H)}3.0kg(6.6lb.) (a staff) 3.6kg(8.0lb.) (a staff and case)

The coefficient of linear expansion : α=20x10-6 [1/°C]

Aluminum staffBAS55: 50mm(W)x27.8mm(D)x5005mm(H)

(5sections){2.0in.(W)x1.1in.(D)x16.4ft(H)}1.9kg(4.2lb.) (a staff) 2.2kg(4.9lb.) (a staff and case)

The coefficient of linear expansion : α=24x10-6 [1/°C]

MeasurementHorizontal circle: Diameter: 103mm

Graduation:1° / 1gonMeasuring range:*1 Height 0 to 5m (16.7 ft) (with BGS50 staff)

Distance 1.6 to 100mMinimum display: Height 0.0001m / 0.001m (0.001ft / 0.01ft) (selectable)

(single, repeat or average mode)0.001m (0.01ft) (tracking mode)

Distance 0.01m (0.1ft) (single, repeat or averagemode)0.1m (1 ft) (tracking mode)

71

Page 74: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

7

Spec

ifica

tions

Accuracy:*1 (with staff BGS50) Height Standard deviation for 1 km of double-run.

DL-502:Electronic Measurement

0.6mm (0.03in.) (with BIS20/30)1.0mm (0.04in.) (with BGS40/50/50G)1.2mm (0.047in.) (with BAS55)

Visual Measurement1.0mm (0.04in.) (with BGS40/50/50G) 1.5mm (0.06in.) (with BAS55)

DL-503:Electronic Measurement

0.8mm (0.03in.) (with BIS20/30)1.5mm (0.06in.) (with BGS40/50/50G)1.7mm (0.047in.) (with BAS55)

Visual Measurement2.0mm (0.08in.) (with BGS40/50/50G)2.5mm (0.06in.) (with BAS55)

Distance ±10mm (less than 10m measurement)±(0.1% x D) (10 to 50m measurement)±(0.2% x D) (more than 50m measurement)(D: measured distance, unit: m)

Measuring modes: Single / Repeat / Average / Tracking(selectable)

Measuring time:*2 Single / Repeat about 3 sec.Average No. of measurements set

× about 3sec.Tracking about 1 sec.

Automatic compensator: Magnetic damping and pendulummechanism

Compensation range: ±15′

*1 When measuring outdoors with minimal atmospheric motion,the staff set up in natural sunlight and luminosity at the surfaceof the staff equal to 20lx.

*2 When measuring to a staff set up outdoors in fine to cloudyconditions.

*1,2 These specifications may change depending on the weatherconditions and measurement conditions.

2

Page 75: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Spec

ifica

tions

PowerPower supply: Rechargeable Li-ion battery (BDC46B)Battery state indicator: 4 levelsWorking duration: more than 16 hours (at 25°C) Charging time: about 2.5 hours*3 (using CDC68)(BDC46B) Nominal voltage: 7.2V Storage temperature range:-20 to 35°C (-4 to 95°F) (CDC68) Input voltage: with EDC113A/113C:110 to 240VAC

50/60Hzwith EDC113B:110 to 125VAC

50/60HzCharging temperature range:0 to 40°C (32 to 104°F)Storage temperature range: -20 to 65°C (-4 to 149°F)

*3 Charging can take longer than the times stated above whentemperatures are either especially high or low.

GeneralDisplay: 128 x 32 dot matrix LCD with illuminatorKeypad: 8 keys (7 keys on front panel;1 key on side

panel)Auto power-off: On (instrument powers off if not used for

30 min.) / Off (selectable)Data output: RS-232C compatibleCircular level sensitivity: 10′/2mmOperating temperature range:-20 to 50°C (-4 to 122°F)Storage temperature range:-40 to 70°C (-40 to 158°F)Water resistance: IPX4Dimensions: 158 (W) x 257 (D) x 182 (H) mm

(6.2(W) x 10.1 (D) x 7.2 (H) inch)Weight (with battery): about 2.4kg (5.3lb)

73

Page 76: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

7

Reg

ulat

ions

22. Regulations

Radio Frequency Interference

WARNING: Changes or modifications to this unit notexpressly approved by the party responsible for compliancecould void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found tocomply with the limits for a Class A digital device pursuant toPart 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interferencewhen the equipment is operated in a commercialenvironment. This equipment generates, uses, and canradiate radio frequency energy and, if not installed and usedin accordance with the instruction manual, may causeharmful interference to radio communications. Operation ofthis equipment in a residential area is likely to cause harmfulinterference in which case the user will be required tocorrect the interference at his own expense.

Notice for CanadaThis Class A digital apparatus meets all requirements ofCanadian Interference-Causing Equipment Regulations.Cet appareil numérique de la Class A respecte toutes lesexi-gences du Réglement sur le matériel brouilleur duCanada.

4

Page 77: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

Reg

ulat

ions

CE Conformity Declaration

For users in California

75

Page 78: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions
Page 79: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

This is the mark of the Japan Surveying Instruments Manufacturers Association.

©2010 TOPCON CORPORATIONALL RIGHTS RESERVED

Page 80: INSTRUCTION MANUAL DIGITAL LEVEL DL-500 SERIESpositionpartners.com.au/file_uploads/DL-500 series_manual_eng.pdf · INSTRUCTION MANUAL DIGITAL LEVEL FC11808-A021-01 ... 3. DL Functions

http://www.topcon.co.jp

GLOBAL GATEWAY http://global.topcon.com/Please see the attached address list or the following website for contact addresses.

DL-502DL-503

INSTRUCTION MANUALDIGITAL LEVEL

FC11808-A021-01

DL-500 SERIES