These instructions contain all the necessary fitting and operating instructions for your electric shower.Care taken during the installation will provide a long, trouble free life from your shower.
INSTRUCTION GUIDE AND USER MANUAL
INSTANTANEOUS ELECTRIC WATER HEATER - MANUAL
AQUAMAX FULL PRO FLEX X JET 9.5KW
AQUAMAX TOP SMART 9.5 KWAQUAMAX FULL PROFLEX SMART 9.5KW
AQUAMAX PRO X JET 9.5 KW
ByAQUABELLA SHOWER CO.,LTD.
PLEASE READ THIS IMPORTANT SAFETY INFORMATION
IMPORTANT
GENERAL ADVICE TO SHOWER UNIT USERS
BATHROOM
FLOOR
CEILING JOISTS
SPILL OVERLEVEL
HOSE RETAINING RING
DOUBLE POLE SWITCH CEILING MOUNTED
GENERAL LAYOUT OF A SHOWER INSTALLATION
AQUAMAX FULL PRO FLEX 9.5 KW
RECOMMENDED INSTALLATION DIMENSIONS FOR ALL MODELSAQUAMAX FULL PRO FLEX , AQUAMAX TOP AND AQUAMAX PRO
No.
1A
1B
2
3
3A
3B
4
5
6
7
8
9A
9B
10A
10B
10C
10D
10E
10F
11
12
13
14
15
16
17
18
19
AQUAS CODE
AS02001CP
AS02086CP
AS06003
AS07018CP
AS07008CP
AS07009CP
AS10001CP
AS05012CP6
AS05015CP
AS09002CP
AS06040CP
AS03076CP
AS03146CP
AS50001WH
AS50001GB
AS50001FC
AS50002WH
AS50002GB
AS50002FC
AS50003
AS50004
AS50005
AS50006
AS50007
AS50008
AS50009
AS50010
AS50011
DESCRIPTION
OVERHEAD - SMART 200 - NO AIR CHROME
OVERHEAD X JET 200 CHROME
2.5mm SEALING WASHER FOR SHOWER HOSE - PACK 5
TOP CONNECTER FOR SHOWER ARM
NON ROTATION SHOWER ARM AND HEATER CONNECTOR FOR AQ5517 / AQ5611
NON ROTATION SHOWER ARM AND HEATER CONNECTOR FOR AQ5518 / AQ5612
FREE FIX WALL BRACKET SET CW FIXINGS
WALL BRACKET PACK FOR SLIDE BAR X 2 ( FREE FIX ) CHROME
SHOWER TUBE 600 X 25MM WITH END CAPS CHROME
FRONT LOADING SLIDER MECHANISM CHROME
SMOOTH 1.5M PVC SHINY HOSE WITH ABS CONICAL NUTS CHROME
HAND SHOWER BELLA 3F - NO AIR CHROME
HAND SHOWER X JET 1F CHROME
HEATER COVER COMPLETE 1 HANDLE WHITE
HEATER COVER COMPLETE 1 HANDLE GLOSS BLACK
HEATER COVER COMPLETE 1 HANDLE FULL CHROME
HEATER COVER COMPLETE 1 HANDLE WHITE
HEATER COVER COMPLETE 1 HANDLE GLOSS BLACK
HEATER COVER COMPLETE 1 HANDLE FULL CHROME
SCREW FIXATION PACK FOR HEATER
THERMAL CUT OFF DEVICE
DIVERTOR VALVE ASSEMBLY FOR AQ5517 AND AQ5518
ELECTRICAL TERMINAL BLOCK
POWER SWITCH ASSEMBLY
GRILLON HEATER TANK ASSEMBLY
VOLUME CONTROL VALVE ASSEMBLY COMPLETE
PRESSURE RELIEF VALVE TUBE
FILTER
SPARE PART DETAILS FOR AQUAMAX WATER HEATERS
AQUAMAX FULL PRO FLEX 9.5 KW MANUAL WATER HEATERS
1B
3B2
3A
11
1A
4
4
2
9A
1112
11
16
18
17 10
10
14
13
15
5
5
5
11
4
4
4
4
2
2
8
6
6
6
7
55
5
5
5
23
9B
AQUAMAX TOP 9.5 KW MANUAL WATER HEATERS
10
10
11
1A
4
4
3A
2
1112
11
16
18
17
14
15
11
4
4
4
4
2
23
1B
3B
2
11
9A
1112
11
16
18
17 10
10
14
13
15
5
5
5
11
2
2
8
6
6
6
7
55
5
5
5
AQUAMAX PRO 9.5 KW MANUAL WATER HEATERS
9B
AQUAMAX FULL PRO FLEX AND AQUAMAX TOP
ASSEMBLY OF UPPER SHOWERING COMPONENTS
4
44
3A
2
23
4
AQUAMAX FULL PRO FLEX AND AQUAMAX PRO
9A
5
5
5
2
8
6
6
6
7
55
5
5
5
ASSEMBLY OF UPPER SHOWERING COMPONENTS
1A
2
Top fixing position
130 mm.
400 mm.
arrow depict water andelectrical entry points.
PLUMBLING CONNECTIONS
PLUMBLING CONNECTIONS
ELECTRICAL CONNECTIONS
ELECTRICAL WIRING
FITTING THE BACK COVER INTO POSITION
DIVERTOR HANDLE ( UPPER HANDLE )
VOLUME CONTROL HANDLE ( LOWER HANDLE )
Make sure that the Divertor spindle and the raised button on the divertor handle are in the
12 O'clock position before fitting the cover.
Turn the stabilizer valve spindle and volume handle fully clockwise until resistance is felt.
Fit cover into position and re-fit cover fixation screws.
Stabilizer valve
Divertor spindle
When fitting the cover, it is important to align the divertor spindle and
volume control spindle inside the heater.
COMMISSIONING THE SHOWER HEATER
3. Before fitting the cover, turn off the electricity supply. Remove this square plastic part in the picture. Fit the front cover. Turn on the water and electricity again, and the product should now work normally
2. Turn on the water and electricity, before fitting the front cover. Push the on/off button, to check water flow and if there is any leakage inside the heater or at any shower connection.
1. Before installation, rotate the volume control handle clockwise until resistance is felt. Connect the water and electricity supply.
IMPORTANT NOTE FOR THE INSTALLER
WARNING ....failure to remove that part after commissioning will result in NO hot water reaching the shower.
OPERATING THE SHOWER
1. Switch on electrical supply - pull cord or wall mounted switch.
2. Press the ON / Off Button to start the flow of water.
3. Turn the divertor handleto select the showeringfunction you requireLeft for Hand-shower& Right for Overhead.
4. When turning the VolumeControl Handle, this willchange the outputtemperature of the water.
5. In the winter months,the heater should be operatedat full power ( 9.5 KW )to ensure an adequate amountof hot waterIn the summer months,the ECO button can be activatedwhich will reduce the KW outputdown to 5.0 KW.
6. To turn off the shower unit,press the ON / OFF button.
IMPORTANT NOTESThe Higher the flow the temperature will decrease.The Lower the flow the temperature will increase.It is recommended that you start the shower with the volume handle in the fully anti clockwise / cold position as this will provide maximum flow If a higher outlet temperature is required, Rotate the volume handle in a clockwise direction.
DIVERTOR HANDLEHAND-SHOWER OR OVERHEAD FUNCTION
VOLUME CONTROL HANDLE
ON / OFF BUTTON
SUMMER SETTING /ECO POWER BUTTON ECO
MAINTENANCE – CLEANING THE FILTER
STEP 1Remove front cover assembly, loosen these two screws, the decor cover can be removed.
STEP 2
STEP 3
Use flat-head screw driver to remove filter, clean it, and refit.
Clean the filter and refit.
FILTER
2. If scale deposits are stubborn, Soak the shower-head or hand-shower in a proprietary Limescale remover and rinse thoroughly before use.
Your AQUAS Branded heaters are supplied by Aquabella Shower Co.,Ltd. in Thailand.
For information or service assistance , please contact the installer or the local
UK distributor from where the heater was purchased.
Ai0051
1. To break away scale deposite on a daily basis simply rub your thumb over the surface whilst the shower is running.
SHOWERHEAD CLEANING INSTRUCTIONS