Institute of Renewable Energy of National Academy of Sciences of Ukraine Yuriy Favorskyy ...
description
Transcript of Institute of Renewable Energy of National Academy of Sciences of Ukraine Yuriy Favorskyy ...
Institute of Renewable Energy Institute of Renewable Energy
of National Academy of Sciences ofof National Academy of Sciences of Ukraine Ukraine
Yuriy FavorskyyYuriy Favorskyy
www.ive.org.uawww.ive.org.ua
+38 044 537-26-57+38 044 537-26-57Kyiv, Kyiv, UkraineUkraine
Structure of Institute of Structure of Institute of renewable energy of renewable energy of
UkraineUkraine
Department of Department of ComplexComplex
energy systemsenergy systems
DepartmentDepartment of wind powerof wind power
Department of Department of organic energy organic energy
sources sources
Department of Department of geothermal energygeothermal energy
Department of Department of hydro hydro
energeticenergetic
Department of Department of solar energysolar energy
Crimea technical Crimea technical and science center and science center of energy saving of energy saving and renewable and renewable
energy energy
Windpower CenterWindpower Center of Ukraineof Ukraine Department Department
of implementationof implementation
The multipurpose integrated hybridThe multipurpose integrated hybridwindwind//PV PV energy systemenergy system
with with control and converting unit (CCU) control and converting unit (CCU) for for autonomous &autonomous & grid reserve grid reserve energyenergy
supplysupply
• with the aeromechanical with the aeromechanical pitch regulation system pitch regulation system
• with low-speed with low-speed synchronous generators with synchronous generators with permanent magnets (PMG)permanent magnets (PMG)
• including hybrid wind/PV including hybrid wind/PV control and converting unit control and converting unit (CCU).(CCU).
Wind energy conversion system (WECS)Wind energy conversion system (WECS)
CPU – processor;I1 – wind turbine generator current
sensor;I2 – inverter and charging unit
current sensor;U – battery voltage sensor;Bat - battery;F – fan;W – wind turbine; WCC – wind turbine generator
current controller;LCD – liquid crystal display;S – sound;I/CU – unit that works in inverter or
charging unit modes;Output 220V – output outlet;CP – control panel;R1 – relay that connects output
220V to the inverter or to the grid;Input 220V – outlet for connection
to the grid 220V;T1 – battery temperature sensor;T2 – radiator temperature sensor;GCU – grid control unit;
Structure diagramStructure diagram
Technology descriptionTechnology description
The blades are turned around their axles by the stabilizers which are placed behind trailing edges of the blades.This system was proposed by professor G. Sabinin in the fifties. We improved this system by changing the method of stabilizer deflection. Our aeromechanical pitch regulation system ensures reliable and effective Wind turbine operation at the wind speed from 2.5 to 55 m/s even when wind is gusty.
The aeromechanical pitch regulation systemThe aeromechanical pitch regulation system
Technology descriptionTechnology description
Our wind turbines have rated wind speed about 7.5 – 9 m/s. It is lower than rated wind speed of the most similar wind turbines of the other manufacturers.
Low rated wind speedLow rated wind speed
The comparison of VEU-075 with two other windmills. VEU-075 has higher power in the most widespread range of wind speed (from 3 to 7 m/s). So ,it produces more energy per month at the same average wind speed.
Instantaneous power dependenceon the wind speed
Power output dependence on the average wind speed (per month)
The differences and advantagesThe differences and advantages
WEU-075
Price and price per kW of the most similar Price and price per kW of the most similar Wind turbineWind turbine of other manufacturers of other manufacturers NameName CountryCountry Rated Rated
Power,Power,P, kWP, kW
Price, Price, ЄЄ Price per Price per kW,kW,
Є/KwЄ/Kw
Wind speedWind speedCut-inCut-in Rated Rated Cut-outCut-out
Inclin 600Inclin 600 SpainSpain 0,60,6 1975*1975* 32923292 3,53,5 1111 1313Rutland FM Rutland FM 18031803
GermanyGermany 0,70,7 1809**1809** 25842584 33 1515 --
EspadaEspada NetherlandsNetherlands 0,750,75 2750***2750*** 36663666 33 1414 --
VEU-075VEU-075 UkraineUkraine 0,750,75
700700 933933
2,52,5 7,57,5 --850*850* 11301130900**900** 12001200
950****950**** 12601260Whishep H40Whishep H40 USAUSA 0,90,9 26362636 29292929 3,43,4 12,512,5 --Whishep H80Whishep H80 USAUSA 11 41874187 41874187 3,13,1 10,510,5 --PassaatPassaat NetherlandsNetherlands 1,41,4 38073807 2719****2719**** 2,52,5 14,014,0 --* - Incl. 7m. Mast ** - Incl. Batt. Charge. Control *** - Incl. 6m. Mast **** - Incl. 12m. Mast
Wind Energy 2003 - Steinbacher Druck GmbH, Osnabruck, Germany
The differences and advantagesThe differences and advantages
The CCU differences and advantagesThe CCU differences and advantagesTechnologies Strengths Weaknesses
Our technology
1.multipurpose integrated hybrid control and converting unit
2. temperature compensation 3. special regime`grid energy
saving
We need to increase numbers of the additional functions, for example: parallel works with diesel and gas generators; using of several types of storage batteries..
Southwest Windpower,
USA
1.SRC-based shunt –type controller
2.Compatibily with any inverter
1.Not multipurpose control and converting
2. Not integrated hybrid unit.
Green power, Germany
1.multipurpose (water) integrated hybrid control and converting unit
1.Not ‘sinus’ output AC.
Market opportunityMarket opportunity 1.6 bill of people haven’t1.6 bill of people haven’t electricityelectricity 0.5 bill have interrupted0.5 bill have interrupted 0.5 bill can sale to grid0.5 bill can sale to grid
BUT IT’S ONLY INDIVIDUALSBUT IT’S ONLY INDIVIDUALS
CCU applications CCU applications
for growing for growing marketmarket
Hybrid systems withHybrid systems with grid connectedgrid connectedfor making moneyfor making money (green tariffs(green tariffs))
Hybrid systems with Hybrid systems with grid reservegrid reserve for uninterrupted energy supplyfor uninterrupted energy supplyfor saving moneyfor saving money
Hybrid wind/PV/hydrowith diesel/gas generatorsautonomous systems
Hybrid wind/PVautonomous systems
Wind systems
ЄЄ Value Value present present marketmarket
Hybrid systems with grid connectedHybrid systems with grid connected ЄЄ 1.5 b
Hybrid systems with grid reserve Hybrid systems with grid reserve for uninterrupted energy supplyfor uninterrupted energy supply
ЄЄ 1 b
Hybrid wind/PV/hydrowith diesel/gas generators
ЄЄ 2 b
Hybrid wind/PVЄЄ 1 b
Wind ЄЄ 0.5 b
04/22/2304/22/23 1313
key strategic partnerskey strategic partnerswind/PV/hydro venders and installerswind/PV/hydro venders and installers
diesel/gas venders and installersdiesel/gas venders and installers
Average CCU world price 1200 Average CCU world price 1200 ЄЄ per kW for per kW for autonomous systemsautonomous systems
OUR price ЄЄ 800
AII DATES FOR AVERAGE 1 kW system
Our market strategyOur market strategy create local marketing trade create local marketing trade
centers with demonstration any centers with demonstration any type samples;type samples;
OEM OEM
Providing system integrated solution with with increasing product lineincreasing product line
We look for:• technological improvement for work with any type energy in any regime (from stand alone to grid solution);• OEM ;•marketing and sales via strategic partners
ЄЄ 0.5 Mil for expansion of 0.5 Mil for expansion of marketing and sales programs, marketing and sales programs, ЄЄ 2 Mil for R&D 2 Mil for R&DЄЄ 1 Mil for production scale up 1 Mil for production scale up
Yuriy FavorskyyYuriy Favorskyy
www.ive.org.uawww.ive.org.ua
+38 044 537-26-57+38 044 537-26-57
Institute of Renewable Energy of National Academy of Sciences of UKRAINEUKRAINE
Kyiv Kyiv