Installation & Operating manualdownloads.hearthnhome.com/installManuals/TLC2000.pdfInstallation &...

26
3-90-08691R17_11/13 SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. FOR USE IN THE U.S. AND CANADA. DO NOT INSTALL IN A MOBILE HOME. IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT. CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN. SAVE THESE INSTRUCTIONS. Installation & Operating Manual Model(s): TLC 2000 Coal/Wood Stove NOTICE: SAVE THESE INSTRUCTIONS Hot glass will cause burns. Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as stove. Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. HOT SURFACES! Glass and other surfaces are hot during operation and cool down. WARNING ! To obtain a French translation of this manual, please contact your dealer or visit www.harmanstoves.com Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www. harmanstoves.com NOTE

Transcript of Installation & Operating manualdownloads.hearthnhome.com/installManuals/TLC2000.pdfInstallation &...

3-90-08691R17_11/13

SAFETY NOTICEPlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr. FAIlurE TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh.

FOr uSE IN ThE u.S. ANd CANAdA. dO NOT INSTAll IN A mObIlE hOmE.

IF ThIS STOvE IS NOT PrOPErlY INSTAllEd, A hOuSE FIrE mAY rESulT. FOr YOur SAFETY, FOllOw INSTAllATION dIrECTIONS.

CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT rESTrICTIONS ANd INSTAllATION INSPECTION

rEQuIrEmENTS IN YOur ArEA.

CONTACT YOur lOCAl AuThOrITY (SuCh AS muNICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT, FIrE PrEvENTION burEAu, ETC.) TO dETErmINE ThE NEEd FOr A PErmIT.

CETTE guIdE d'uTIlISATION EST dISPONIblE EN FrANCAIS. ChEz vOTrE CONCESSIONNAIrE dE hArmAN.

SAvE ThESE INSTruCTIONS.

Installation & Operating manual

model(s):TLC 2000 Coal/Wood Stove

NOTICE: SAVE THESE INSTRUCTIONS

hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomas

stove.• Alertchildrenandadultstohazardsofhightemperatures. high temperatures may ignite clothing or other

flammable materials.• Keepclothing,furniture,draperiesandotherflammable

materialsaway.

hOT SurFACES!

Glassandothersurfacesarehotduringoperationandcooldown.

WARNING!

To obtain a French translation of thismanual, pleasecontactyourdealerorvisitwww.harmanstoves.com

Pourobtenirunetraductionfrançaisedecemanuel,s’ilvous plaît contacter votre revendeur ou visitezwww.harmanstoves.com

NOTE

3-90-08691R17_11/13

Repo

rt #/

Rapp

ort #

135-

S-28

-4Te

sted t

o / Te

sté à:

UL 1

482-

2011

, UL 7

37-2

011,

and U

LC-S

627-

00

DO N

OT IN

STAL

L IN

A M

OBIL

E HO

METh

is ap

plian

ce is

appr

oved

for in

stalla

tion i

nto a

shop

.

“PRE

VENT

HOU

SE F

IRES

”Ins

tall a

nd u

se o

nly in

acc

orda

nce

with

manu

factur

er’s

instal

lation

and

ope

ratio

n ins

tructi

ons a

nd lo

cal c

odes

. In

abse

nce o

f loca

l cod

es, in

stalla

tion m

ust m

eet m

inimu

m re

quire

ments

of N

FPA 2

11 in

USA

. Refe

r to m

anufa

cture

r’s

instru

ction

s and

loca

l cod

es fo

r pre

cauti

ons r

equir

ed fo

r pas

sing c

himne

y thr

ough

a co

mbus

tible

wall o

r ceil

ing.

Flue

conn

ector

pipe

mus

t be

6” d

iamete

r, mi

nimum

24

MSG

blue

steel.

Chim

ney m

ust b

e fac

tory b

uilt 1

03HT

or

maso

nry c

onstr

uctio

n.

Cont

act L

ocal

Build

ing

or F

ire O

fficia

ls Ab

out R

estri

ctio

ns an

d In

stall

atio

n In

spec

tion

In Yo

ur A

rea.

DO N

OT C

ONNE

CT T

HIS

UNIT

TO

A CH

IMNE

Y FL

UE S

ERVI

NG A

NOTH

ER A

PPLI

ANCE

.U.

S.A.

- FOR

USE

wIT

H SO

LID

wOO

D (A

S A

FIRE

PLAC

E) O

R CO

AL F

UEL

ONLY

.CA

NADA

- CO

AL A

ND/O

R w

OOD

wHE

RE L

OCAL

COD

ES A

LLOw

.w

ARNI

NG! T

he U

se O

f Any

Oth

er Fu

el Is

Not P

erm

itted

. Ref

er to

oper

atio

n sec

tion o

f the

appl

iance

man

ual.

DO N

OT O

verfi

re -

If He

ater

or c

him

ney C

onne

ctor

Glo

ws, Y

ou A

re O

verfi

ring.

Optio

nal B

lowe

r Har

man

#1-0

0-08

643:

Elec

trical

Ratin

g 115

VAC

, 60H

z, 1 A

MP M

axim

um

Route

Pow

er C

ord A

way F

rom

Unit.

Pour

venti

ateur

en op

tion n

o, 1-

00-0

8643

Seu

lemen

teRe

place

glas

s only

with

5mm

cera

mic,

avail

able

from

your

deale

r.Co

mbus

tible

floor

ing m

ust b

e pro

tected

with

a no

n-co

mbus

tible

mater

ial.

wAR

NING

: Risk

of S

moke

and

Flam

e Sp

illage

, Ope

rate

Only

With

Doo

rs Fu

lly O

pen

or F

ully C

losed

. Fire

scre

en

Must

Be in

Plac

e Whe

n Bur

ning W

ith th

e Doo

r Ope

n.

DANG

ER: R

isk of

Fire

or E

xplo

sion -

Do N

ot B

urn G

arba

ge, G

asol

ine,

Drain

Oil o

r Oth

er Fl

amm

able

Liqu

ids.

wAR

NING

: Risk

of F

ire:

Do N

ot S

tore

Fue

l or C

ombu

stib

les w

ithin

Mar

ked

Clea

ranc

e Are

a.In

spec

t and

Clea

n Ch

imne

y Fr

eque

ntly-

Und

er C

erta

in C

ondi

tions

of U

se, C

reos

ote

Build

up M

ay O

ccur

Ra

pidl

y.

Do N

ot In

stall

a Gr

ate R

ack o

r Oth

erwi

se E

levat

e the

Fire

Abo

ve th

e Fac

tory

Inst

alled

Gra

tes.

NO H

omolo

gué p

our le

s mais

ons m

obile

s et p

réfab

riqué

es

Cet a

ppare

il est

égale

ment

homo

logué

pour

être i

nstal

lé da

ns un

ateli

er.

«ÉVI

TEZ

LES

INCE

NDIE

S DE

MAI

SON»

N’ins

tallez

et n

’utilis

ez c

et ap

pare

il que

selo

n le

mode

d’in

stalla

tion

et le

mode

d’em

ploi d

u fab

rican

t et

les c

odes

loca

ux. E

n l’a

bsen

ce d

e co

des

locau

x, l’in

stalla

tion

doit

au m

inimu

m êtr

e co

nform

e au

x ex

igenc

es d

e la

norm

e NF

PA 2

11 a

ux É

.-U. V

oir d

ans

les re

comm

anda

tions

du

fabric

ant e

t dan

s les

cod

es lo

caux

les

préc

autio

ns q

uant

au p

assa

ge d

’une

chem

inée

à tra

vers

un m

ur o

u un

plaf

ond

comb

ustib

le.Le

tuya

u de r

acco

rd à

la ch

eminé

e doit

être

d’un

diam

ètre d

e 15,2

5 cm

(6 po

), au m

inimu

m en

acier

bleu

24

MSG

. La c

hemi

née d

oit êt

re en

méta

l 103

HT d’

usine

ou co

nstru

ite en

maç

onne

rie.

CONS

ULTE

X LE

S AD

MINI

STRA

TION

S ET

OR

GANI

SMES

CO

MPET

ENTS

PO

UR

LA

CONS

TRUC

TION

ET

LA P

REVE

NTIO

N DE

S IN

CEDI

ES A

FIN

DE R

ESPE

CTER

LES

REG

LES

DE

SECU

RITE

EN

VIGU

EUR.

NE R

ELIE

Z PA

S CE

POÊ

LE À

UNE

CHE

MINÉ

E QU

I SER

T PO

UR U

N AU

TRE

APPA

REIL

.U.

S.A.

-pou

r l'ut

ilisat

ion

avec

le b

ois

solid

e (c

omm

e un

e Ch

emin

ée) o

u un

cha

rbon

alim

ente

nt

seul

emen

t.Le

Can

ada -

Le c

harb

on et

-ou

le bo

is où

les c

odes

loca

ux p

erm

ette

nt.

AVER

TISS

EMEN

T! L'

Utilis

atio

n d'A

utre

Com

bust

ible

n'Est

pas P

erm

ise. S

i l’ap

pare

il ou l

e rac

cord

de

chem

inée r

ougit

, c’es

t que

le fe

u est

trop p

uissa

nt.Po

ur ve

ntiate

ur en

optio

n no,

1-00

-086

43 S

eulem

ente

Éloig

nez l

e cor

don é

lectriq

ue de

l’app

areil

.

DANG

ER: R

isque

de

déch

arge

élec

trique

. Déb

ranc

hez

la pr

ise a

vant

tout e

ntreti

en.

Pour

plus

de

détai

ls, co

nsult

ez le

mod

e d’em

ploi.

Ne re

mplac

ez le

verre

que p

ar du

verre

céra

miqu

e de 5

mm

à obte

nir de

votre

détai

llant.

L’app

areil

doit ê

tre in

stallé

avec

ses p

ieds fi

xés.

N’ob

strue

z pas

le pa

ssag

e d’ai

r sou

s l’ap

pare

il.

DANG

ER: R

isque

d’inc

endie

ou d’

explo

sion.

Ne br

ûlez p

as d’

ordu

res,

d’ess

ence

, d’hu

ile de

vida

nge n

i au

cun a

utre l

iquide

infla

mmab

le.

MISE

EN

GARD

E: R

isque

d’inc

endie

.N’

utilis

ez pa

s le p

oêle

lorsq

ue le

s por

tes du

foye

r et d

u cen

drier

sont

ouve

rtes.

Gard

ez le

carb

uran

t et le

s maté

riaux

comb

ustib

les en

deho

rs de

s dég

agem

ents

pres

crits.

Inspe

ctez e

t nett

oyez

fréq

uemm

ent le

s con

duits

et la

chem

inée.

CAUT

ION

- HO

T w

HIle

IN O

perA

TIO

N - D

O N

OT

TOUC

H - K

eep

CHIl

DreN

AND

ClO

THIN

g A

wAy

- CO

NTAC

T m

Ay C

AUse

sKI

N b

UrNs

. see

NAm

eplA

Te A

ND IN

sTrU

CTIO

Ns. K

eep

fUrN

IsHI

Ngs

AND

OTH

er

COm

bUsT

Ible

mAT

erIA

ls A

CO

NsID

erAb

le D

IsTA

NCe

AwAy

frO

m T

He A

pplI

ANCe

.

ATTe

NTIO

N: C

HAU

D lO

rs D

U fO

NCTI

ONN

emeN

T -

Ne T

OUC

HeZ

pAs

l’Ap

pAre

Il -

gAr

DeZ

les

eNfA

NTs

eT l

es V

ÊTem

eNTs

ÉlO

IgNÉ

s -

TOUT

CO

NTAC

T pe

UT e

NTrA

ÎNer

Des

brÛ

lUre

s D

e lA

peA

U.

rÉfÉ

reZ-

VOUs

À l

A pl

AQUe

sIg

NAlÉ

TIQ

Ue e

T AU

mO

De D

’em

plO

I. g

ArDe

Z le

mO

bIlI

er e

T le

s AU

Tres

m

ATÉr

IAUX

CO

mbU

sTIb

les

bIe

N À

l’ÉC

ArT

De l

’App

AreI

l.

Made

in U

.S.A

. of U

S an

d im

porte

d pa

rts. /

Fabr

iqué

aux É

tats

-Uni

s-d’

Amér

ique

par

de

s pièc

es d

’orig

ine a

mér

icain

e et p

ièces

impo

rtées

.

Floo

r pr

otec

tion

mus

t be

of a

non

-com

bust

ible

mat

erial

. Mus

t also

be pl

aced

unde

r any

horiz

onta

l se

ctio

ns o

f flue

con

nect

or, e

xten

ding

2”

(51m

m)

beyo

nd ea

ch si

de o

f the

conn

ecto

r.

Pour

pro

tége

r le

plan

cher

, il f

aut s

ous

le po

êle

un m

atér

iau n

on-c

ombu

stib

le. Q

ui d

oit a

ussi

être

pl

acé

sous

les

parti

es h

orizo

ntale

s du

tuya

u de

ra

ccor

d à l

a che

min

ée et

s’ét

endr

e à 51

mm

(2 p

o)

au-d

elà d

e lat

eral

du tu

yau.

gg

H

J

BARC

ODE

LABE

LSo

lid F

uel B

urni

ng R

oom

Hea

ter

Mode

l “TL

C 20

00”

Seria

l No.

No de sé

rie:

008

CLEA

RANC

E TO

COM

BUST

IBLE

S /

DIST

ANCE

S MI

NIMA

LES

DE S

ECUR

ITE:

ef

fe

AC

D b

C DbApara

llel I

nsta

llatio

nIn

ches

Mill

imet

ers

Bac

k W

all /

Ent

re m

ur a

rrie

reet

l’ap

pare

il

Sid

e W

all T

o U

nit /

Ent

re m

ur la

tera

l et l

’app

arei

lB

ack

Wal

l To

Flue

Pip

e / E

ntre

tuy

au e

t le

mur

arr

iere

Sid

e W

all T

o Fl

ue P

ipe

/ Ent

re tu

yau

et le

mur

late

ral

feW

alls

to U

nit B

ody

/ Ent

re m

ur a

djac

ent e

t l’a

ppar

eil

Wal

ls to

Flu

e P

ipe

/ Ent

re tu

yau

et le

mur

adj

acen

t

Cor

ner I

nsta

llatio

nIn

ches

Mill

imet

ers

HgS

ides

/ C

ôtés

Fron

t- fro

m g

lass

/Dev

ant,

par r

appo

rt au

ver

re- U

SA

JR

ear /

Arr

ière

- U

SA

and

Can

ada

HFr

ont-

from

gla

ss/D

evan

t, pa

r rap

port

au v

erre

- C

anad

a

floo

r pro

tect

ion

req

uire

men

tsIn

ches

Mill

imet

ers

P.N. 3

-90-

0869

0Re

v Cm

anuf

actu

red

by /

fabr

iqué

par

: Hea

rth

and

Hom

e Te

chno

logi

es

Dat

e of

man

ufac

ture

/ D

ate

de fa

bric

atio

n:20

13

2014

20

15

JAN

fe

b

mA

r

Apr

m

Ay

JUN

JU

l A

Ug

se

p O

CT

NO

V D

eC

5.25”

15.5

16 18 18 27

405

457

457

685

12 18

305

457

8 16 18 8

203

203

457

203

Sam

ple

labe

l - C

onsu

lt ac

tual

uni

t lab

el

for a

ccur

ate

info

rmat

ion.Pleasecopyyourserialnum

berfrom

thelabelonyourstovetothebox

below. SE

rIA

l N

um

bEr

4 3-90-08691R17_11/13

352 Mountain House RoadHalifax, PA 17032

USA

Introduction

Pleasereadthisentiremanualbeforeyouinstallanduseyournewroomheater.Failuretofollowinstructionsmayresultin

propertydamage,bodilyinjury,orevendeath.

dO NOT INSTAll IN A mObIlE hOmE.

SAVETHESEINSTRUCTIONS

Note:Thisapplianceisalsoapprovedforinstallationintoashop.

Appliance Certification.model:TLC2000

listed by:OMNI-TestLaboratories,IncReport#:135-S-28-4

Type:SolidFuelBurningRoomHeaterStandard(s):UL1482-2011,UL737-2011,ULC-S627-00

= Contains updated information

Table of Contents

Specifications . . . . . . . . . . . . . . . . . . . . . . . .6

Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . .8

building a Fire. . . . . . . . . . . . . . . . . . . . . 9-12

maintenance. . . . . . . . . . . . . . . . . . . . . . 13-14

Installation. . . . . . . . . . . . . . . . . . . . . . . 15-16

Chimney System. . . . . . . . . . . . . . . . . . 17-19

Service Parts list . . . . . . . . . . . . . . . . . 20-22

warranty. . . . . . . . . . . . . . . . . . . . . . . . . 23-24

Service & maintenance log. . . . . . . . . . . .25

3-90-08691R17_11/13

Never sleep in the same room with any coal burning stove

Carbon monoxide (CO) Awareness

Carbon monoxide, referred to as CO, is a colorless, odorless gas that is produced during combustion of coal and other fuels. CO fumes are toxic and can be fatal.The TLC 2000 is a natural draft system which relies on a properly designed chimney to remove CO and other combustion by-products from the stove.Even though this stove is designed to be as safe as possible, it is important that you install a CO detector. This is true for oil, gas, or wood as well.CO is not specifically heavier or lighter than air. Therefore, it is best to install the detector at table top level rather than on the ceiling like a smoke detector.

CO detectors are very sensitive and may sound an alarm for fumes other than CO or CO from sources other than the stove such as car or lawn mower exhaust.If the alarm sounds 1. Increase ventilation by opening windows or doors.2. Make sure the stove doors are closed and latched.3. Check stove for normal operation.4. Check for false alarm.5. Have all occupants exit the building until the cause for the

alarm is discovered and/or remedied.

NEvEr uSE gASOlINE, gASOlINE-TYPE lANTErN FuEl, kErOSENE, ChArCOAl lIghTEr FluId, Or SImIlAr lIQuIdS TO STArT Or “FrEShEN uP” A FIrE IN ThIS hEATEr. kEEP All SuCh lIQuIdS wEll AwAY FrOm ThE hEATEr whIlE IT IS IN uSE.

dO NOT INSTAll A FluE dAmPEr IN ThE ExhAuST vENTINg SYSTEm OF ThIS APPlIANCE.

dO NOT CONNECT ThIS uNIT TO A ChImNEY FluE SErvINg ANOThEr APPlIANCE

INSTAll vENT AT ClEArANCES SPECIFIEd bY ThE vENT mANuFACTurEr.

dO NOT CONNECT TO ANY AIr dISTrIbuTION duCT Or SYSTEm.

dO NOT uSE ChEmICAlS Or FluIdS TO STArT ThE FIrE.

dO NOT burN gArbAgE Or FlAmmAblE FluIdS SuCh AS gASOlINE, NAPThA, Or ENgINE OIl

hOT whIlE IN OPErATION. kEEP ChIldrEN, ClOThINg ANd FurNITurE AwAY. CONTACT mAY CAuSE SkIN burNS.

whEN INSTAllINg IN A TIghTlY CONSTruCTEd hOmE, A SOurCE OF FrESh AIr TO ThE rOOm mAY bE NECESSArY FOr PrOPEr OPErATION OF ThIS APPlIANCE.CAUTION!

FAIlurE TO FOllOw ThE INSTAllATION INSTruCTIONS IN ThIS mANuAl, Or uSINg mAkEShIFT COmPrOmISES durINg INSTAllATION mAY rESulT IN PrOPErTY dAmAgE, PErSONAl INjurY Or EvEN dEATh.

6 3-90-08691R17_11/13

SpecificationsWeight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375lbsFlueSize. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6InchFuel:uSA:Pea,Nut,orStovecoal,CordwoodwithoptionalsparkscreenCanada:Wood,orcoalasabove.WoodaloneaslocalcodesallowLogLengthRecommended. . . . . . . . . . . . . . . . . . . . . . . 16"with18"MaxBTU/HourInput. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72,000HeatingCapacity*. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,200-3,000sq.ftBlowerSize(Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . 135cfm(VariableSpeed)

*heating capacity to be used as a guide only. See your local dealer for help in determining the product that best suits your heating needs based on climate and home efficiency.

7 3-90-08691R17_11/13

Top Load Door

Top Load Door Arm

Side Shield

Ash Door LatchAsh Door

Coal Air Control

Front Load Door Latch

Top Load Opening

Glass Door

Grates (2)

Wood Air Control

Removable Shaker Handle

Clean-out Cover

Coal Bars (3)

unit Overview

8 3-90-08691R17_11/13

Operation

The StovedoorsYourstovehasalargeglass-paneleddoorforloadingandfireviewing,aseparatesmallerdoorforremovingashesandatoploadingdoor.Toopentheglassdoor,turnthehandleclockwiseandpullout;toclosethedoor,returnthehandletoanopen9o'clockpositionandpushintoengagethelatchwhileturningthehandlecounterclockwisetothe6o'clockposition.Toopentheashdoor,liftuponthehandleandpullout.Closethedoorbypushinginandpushingthehandleallthewaydown.Toopenthetoploaddoormovethewoodenknoblocatedontheleftsideofthestovefrontandupwarduntilitlocksthetopopen.All doorsmust be closedwhile the stove is in normaloperation,andthegasketsroutinelyexaminedforwearandreplacedwhennecessary.Theglassdoormaybeleftopenandtheopeningcoveredwithascreenwhenoperatingasafireplace.Gooddoorsealsareimportantformaintainingcontrolofthestove.Operatingthestovewiththeashdooropen, orwith a door inadequately sealed, could createaseriousoverfiringcondition(discussedlaterinthissection).NEvEr OPErATE wITh mOrE ThAN ONE dOOr OPEN AT A TImETheglassusedinyourTLC2000ismanufacturedtoexactstandardstowithstandthehighheatofthefire,butlikeallglass,itmustbetreatedwithcommonsenseandcare.Neverabusetheglassbyslammingthedoorshutorstrikingtheglasswithaheavyobject.Iftheglassisbrokenordamaged,donotoperatethestoveuntilithasbeenreplaced.Thecoalbarsmustbeinstalledtoprotecttheglass.Neverbuildafiredirectlyagainsttheglass.

grates TheTLC2000’suniquegratesystemconsistsoftwoCastirongrateslinkedtogethertooperatesimultaneouslywhentheexternalshakerhandleismoved.Thepurposeofthegratesystemistosupportthecoalbedwhileairflowsupthroughthegratestotheburningcoal.Thegratesarealsousedtoremoveashesfromthebottomofthecoalbedwhilethefireisburning.Thisisaccomplishedbyshakingtheshakerleverbackandforthwithshortchoppystrokes.Thiscausestheashestofallthroughthegratesintotheashpan.ItisthespecialdesignoftheHarmanGratesthatallowslongerintervalsbetweenrefuelingandshakingthegrates.rEmOvAl Or mOdIFICATION OF ThIS grATE SYSTEm mAY CAuSE A dANgErOuS SITuATION.

Fuels for uSACoalAnthracite coal, pea or nut size, is the primary fuel forwhichtheTLC2000isdesigned.Bituminouscoalmayalsobeburnedbut the resultswill varydue to thevariation inbituminouscoalfromregiontoregion.

woodWoodmaybeburned in theTLC2000 for thepurposeofignitingcoal.Woodmayalsobeburnedwith theglassdoor openanda screen in place to prevent sparks fromescaping.Thisprovidesarealopenfireatmosphere.

Fuels for CanadawoodWoodmaybeburnedasaprimaryfuel,providingthatyourlocalandprovincialcodesallowit.Woodmayalsobeburnedwiththeglassdooropenandascreeninplacetopreventsparksfromescaping.

CoalAnthracitecoal,peaornutsize,mayalsobeburnedasaprimary fuel for theTLC2000.Bituminous coalmay alsobeburnedbut the resultswill varydue to thevariation inbituminouscoalfromregiontoregion.Fuel shouldbestored inadryplace,prefferably indoors.Keepfueloutsidetheinstallationclearancearea.Also,keepfuelawayfromallmaintenanceaccessareas.

harman TlC 2000 grate System

uSE OF FuElS OThEr ThAN ThOSE SPECIFIEd wIll vOId ThE PrOduCT wArrANTY ANd mAY POSE A rISk TO PErSONAl hEAlTh ANd SAFETY.

CAUTION!

9 3-90-08691R17_11/13

Air ControlsCoalThe primary air control for coal burning isaknoblocatedonthebottomdoor.Slidingtheknobtotheleftprovideslessairforasmallerfire.Slidingtheknobtotherightprovidesmoreairforalargerfire.Whenburningwood,thisknobshouldbeallthewaytotheleft,closed.

woodThe primary air controls for wood burning arelocatedoneachsideasshownatleftandonpage6.Bothcontrolsshouldbeadjustedequally.Airfromthesecontrolsalsoprovidesacurtainofairacrosstheglasstokeepitclean.Movethecontrolsdownforlessheatandupformoreheat.Whenburningcoalthesecontrolsshouldbeinthedownposition.

wOOd

COAl

wOOd

building and maintaining a wood Fire Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in useCrumpleupsixtoeightsheetsofnewspaperandplaceinthefirebox.Nextplacepiecesofdrywood3/4inchmaximumdiameter on top of the paper,Next placeseveral1"-2"splitpiecesofdrywoodontop,followedbyafew2"-3"splitpieces.Setthewoodaircontrolsatthemaximumheatoutputsetting,allthewayup.Placetheknobonthebottomdoortotheleft.Thesesettingswillallowtheglasstostaycleanasyoubuildyourfire.Thecoalknobmaybemovedtotherighttospeedtheignitionprocessbuttheglassmaygetdirty.Ignitethepaperandallowthefiretoburnuntilagoodcharcoalbed,2"-3"(50mm-80mm)isformed;(Youmayneedto leavetheashdooropenacrack togetthe blaze going properly, but never leave the stoveunattendedwithadooropen.)Addmorewoodtocreateadeepercharcoalbase3"to4".Oncethecharcoalbedisestablishedyoumayaddafullloadofdrywood.Afteraddingthefuel,leaveairsettingatmaximumfor5to15minutes.Then,adjusttheaircontrolsandblowerspeedforthedesiredheatoutput.

building & maintaining a Fire

CAUTION!ThE OPErATION rANgE OF ThE AIr CONTrOlS mAY NOT bE AlTErEd FOr ANY rEASON.

CAUTION!AlwAYS wEAr FIrE-rESISTANT glOvES TO OPErATE ThE STOvE. ThE AIr CONTrOl IS hOT whIlE IN OPErATION.

Coalmusthaveaircomingupthroughthecoalbedinordertoburn.Someairoverthetopofthecoalhelpsburngases.A small amount of air enters the topofthecoalfirewhenthewoodcontrolsareinthedownposition.Woodburnswith toporbottomair;however, topaircomingdownacrosstheglassto formanaircurtainworksbestandkeepstheglassclean.Thisiswhyitisrecommendedthatthecoalcontrolbepositionedtotheleftforwoodburning.

CAUTION!The wood controls are hot. use the removable shaker handle or gloves to adjust these controls

10 3-90-08691R17_11/13

Remove Cleanout Plate To Burn As A Fireplace Stove

Ashes should be placed in a steel container with a tight fitting lid and moved outdoors immediately. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste shall not be placed in this container.

reloading Onceyouhavepreparedandmaintainedathickcharcoalbed, you shouldbeable to reload the stove, allowsomeburningatthemaximumairsetting,andresettheaircontrolinafewminutes.Selecthardwoodsifpossible,astheyareheavierandcontainmoreheatingcapacity(BTU’s)perloadthandosoftwoods.Woodshouldbesplitandstoredundercoverfor“seasoning”- ayearisrecommended.Yourstoveisnotanincinerator- donotburngarbage,paintedortreatedwood,plastic,or

otherdebris.Keep the area around the stove free from clutter. Keepallcombustibles, including fuel,beyond thecode-requiredclearancedistance(48"or1215mmintheU.S.,1525mmor60"inCanada).Neverstorefuelinfrontofthestovewhereitcouldinterferewithdooroperation,safeloading,andashremoval.Blower.Toregulatethespeedoftheoptionalconvectionblower,adjustthecontrolfromlowtohighbyturningtheknoblocatedontheblowercord.removing wood Ashes Alwayswearglovestoremovetheashpan.Liftthelatchontheashdoorandopen.Pulltheashpanoutbythehandle.Liftthehandletotheverticalpositiontocarrytheashestoadisposallocation.Closetheashdoorwhileyouaredisposingoftheashes.Thefirewillgetveryhotifthebottomdoorisleftopenevenforashortperiod.Replacetheashpan.Removeashes from the fire chamber periodically by shaking thegrates.Woodburnsbestwithanashbedunderthewood;therefore,donotshakealloftheashesdown.Neverlettheashesbuilduptoover3"indepth.Excessiveashbuildupcanpreventproperventingofexhaustgases.Alsodonotoverfilltheashpan.Ashbuildupbetweentheashpanandthegratescancausethemtooverheatandwearoutprematurely.Operating as a FireplaceTheTLC2000istestedandapprovedtobeburnedwiththefrontloaddooropen.Inthismodeofoperationyougetatruefiresoundaswellasappearance.Duetothecracklingandpoppingofburningwooditisnecessarytoplacetheoptionalscreenover thedooropening.Thisprevents sparks fromenteringtheroomjustlikeascreenoverafireplace.Theclean-outplate(seeabove)shouldberemovedtoburnasafireplace.Thisisdonebyliftinguponthetabonthefrontoftheplate.To install the screen, open the glass door andplace thescreenoverthedooropening.Pushonthescreenuntilthetwospringclipssnapintoplace.Toremovethescreen,pullonthehandle.

building & maintaining a Fire

11 3-90-08691R17_11/13

building & maintaining a Fire

1. grates 4. Fresh Coal2. Ashes On grates 5. Ashes in Ash Pan3. Partly burned Coal 6. grate bars

2

3

5

1

46

building and maintaining a Coal Fire;Buildawoodfireasdescribedbutinsteadofaddinglargerwood,limitthesizetoabout2"indiameter.Addenough2"woodthatthefireboxflooriscoveredwithburningwood.Afterthewoodisburningwellforaboutfiveminutes,putthewoodaircontrolsinthedownpositionandslidethecoalaircontroltotheright.Thismakestheprimaryairflowupthroughthegratesasisrequiredforcoalburning.Nextaddalayerofcoalontopofthewood.Continueburninguntilthelayerofcoalisturningredandigniting.Itispossibletospeedthisprocessbyopeningtheashdoor,butneverformorethanfiveminutesatatime.Operationwiththeashdooropenformorethanfiveminuteswilloverfirethestoveandmaycausedamagetothestove.Neverleavethestoveunattendedwiththeashdooropen.After the layerof coal isburning,asecond layermaybeadded.Afterthesecondlayerisburning,morelayersmaybeadded. Do not add coal above the firebricks or grate bars. The stove is hot while in operation. keep children, clothing and furniture away. Contact may cause skin burns.Asyoubegintooperateyourstoveathighertemperatures,youwillnoticea“hot”orunpleasantsmell; this is just thepaintgoingthroughthecuringprocess,andwilldisappearafterafewfires.OverfiringAvoidoverfiringyourstove.Thisisapotentiallyhazardoussituationwhichcanleadtotheoverheatingofcombustiblewallorfloormaterials,damagetothestove,andinextremecases, cause a fire.Overfiring is caused by:Toomuchair flowing through the stove too quickly.Youmay haveinadvertentlyleftthebottomdooropen.Or,Notkeepingupwithroutinemaintenance,suchascheckingdoorgasketsforwear.Thechimneymayhaveexcessivedrawordraft,whichcanberemediedbyinstallingabarometricdamperOverfiringresultsinexcessivefuelconsumption,andmaycausepartsofthestoveorchimneyconnectortoglowred.Ifyounoticesignsofoverfiring,reducetheairsupplytothefire,andreviewtheMaintenancesectioninthismanual.Donotburnthestovecontinuouslyatthemaximumsetting.Ifmaximumheatisrequireddayafterday,thestoveistoosmallfortheareayouaretryingtoheat.Never leave the stove unattended if either the ash or load door is open. Overfiring may result.Intheeventofachimneyfire,callyourlocalfiredepartment;makesureeveryoneissafelyoutofthehouse.Reducetheairintakeofthestoveasmuchaspossibleusingtheaircontrollever.Donotthrowwateronthefire;thiscancausestovedamageandcreateanevenmoredangeroussituation.Haveyourchimneyprofessionallycleanedandinspectedbeforeresumingburninginyourstove.

12 3-90-08691R17_11/13

building & maintaining a Fire

CookingGrill

Handle

HandleAshPan

disposal of Ashes.TheTLC2000wasdesignedtoprovideaccesstotheashpanwithouttheneedforopeningthemaindoor.Wearingheavyprotectivegloves,opentheashdoorandremovetheashpanbypullingitforwardbythehandle.Closetheashdoorbeforetakingtheashesoutsideforsafedisposal.Agood time toempty theashpan isbefore loading.Thisensuresthattheasheswillbecoldandsafertohandlethandirectlyaftershakingtheashesdownortendingthefire.Ashes should be placed in a steel container with a tight fitting lid and moved outdoors immediately. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste shall not be placed in this container.refuelingOpenthecoalaircontroltothemaximumpositionbyslidingit to the right.Allow thefire toburnvigorously forseveralminutes.Shakethegrateswithshortchoppystrokesuntilthefirstredcoalsfallintotheashpan,thenstop!Addcoaltothetopofthecoalbed.Itisgoodtoallowsomeredhotcoalsexposedtohelpignitethegasescomingoffofthenewlyaddedcoal.Thesegasescanbevolatileiflefttoaccumulate.Thecoalaircontrolmaybereturnedtothedesiredsetting.Stainless Steel Cooking grill (Optional)The cooking grill can be used for open fire grilling overanthracitecoalorwood.Toinstallthegrill,placethehandleinthegrillasshownatleft.Thegrillcannowbeliftedandpositionedintheopeningontopofthestoveasshownbelowleft.

CAUTION!COOkINg grIll mAY bE hOT. Alwayswear gloveswhenhandlingthegrill.

Cookingonanthracitecoalproducesflavorsimilartoagasgrill.Cookingonwoodproducesmanyflavorsdependingonthetypeofwoodused.Moreflavor isaddedwhencooking isdonewiththetopclosed.Thiscausestheheatandsmoketocirclearoundthefood.Aswithgrillingoranyopenfirecooking,theamountofheatandcookingtimemustbeexperimentedwithforbestresults.

13 3-90-08691R17_11/13

maintenanceLike all fine equipment, your TLC 2000 requires someroutinemaintenanceandinspection.Followtheguidelinesinthissectiontoguaranteesafe,efficientoperation.The StoveSurfaceThestove’sexteriorsurfaceshouldbedustedperiodicallywith a soft cloth. Formore thorough cleaning,wait untilthe stove is cool beforeusingadampcloth to cleananyblemishes.

ControlsToavoidarustbuild-upontheinnersurfacesofthecontrols,workthecontrolsbackandforthseveraltimes,duringthesummer,oranyprolongedperiodwhenyouarenotusingyourstove.The Fire ChamberThe inside of the fire chamber should be examined fordamagetothefirebrickliningmaterial,andgrates.Ifanybricks have been damaged, replace themwithHarmanreplacementparts.

venting System / ChimneyCreosote-Formationandtheneedforremoval-Whenwoodisburnedslowly,itproducestarandotherorganicvapors,whichcombinewithexpelledmoisturetoformcreosote.Thecreosotevaporscondenseinacoolchimneyofaslowburningfire.Asa result,creosote residueaccumulates in thefluelining.Whenignited,thiscreosotemakesanextremelyhotfire.Thechimneyconnectorandchimneymustbeinspectedatleastonceeverytwomonthsduringtheheatingseasontodetermineifacreosotebuild-uphasoccurred.Ifasignificantlayerofcreosotehasaccumulated(3mmormore),itmustberemovedtoreducetheriskofachimneyfire.Intheeventofachimneyfire,callyourlocalfiredepartment;makesureeveryoneissafelyoutofthehouse.Reducetheairintakeofthestoveasmuchaspossibleusingtheaircontrollever.Donotthrowwateronthefire;thiscancausestovedamageandcreateanevenmoredangeroussituation.Haveyourchimneyprofessionallycleanedandinspectedbeforeresumingburninginyourstove.

glass - replacementTheglassinthisunitisaceramicglass.5mmX444mmX311mm.availablefromyourHarmandealer.Ifthestove’sglassiscrackedorbroken,youmustreplaceit before operating your stove.Remove pieces carefully.ReplaceglassonlywithHarmansuppliedreplacementglasspanels;donotusesubstitutes.Toreplacetheglasspanel,youwillneedtoremovethedoor.Todothis,openthedoor,liftitstraightupandplaceitonasoftsurface.Carefullyremovedamagedglass,gasketmaterial,andholddownclips(setaside).Referringtothediagram,notehowthevariouscomponentsofthedoorsystemfittogether.Laytheloaddoorfacedownonthesoftsurface,andinstalltheselfadhesive1/4"gasketmaterialaroundthefrontfaceoftheglass.Settheglasspaneandgasketgentlyontothedoor.Installtheholddownclipsandtightenwithboltsasshown.Reinstalldooronstove.

DoorGlassGasket

Glass

HoldDownClipsandBolts

14 3-90-08691R17_11/13

gaskets are located:Onthedoorstoprovideairtightclosure.Onthelid.

handleThehandleonthefrontdoorofyourTLC2000isattachedtoathreadedshaft.Afteraperiodoftime,youmayfindthatthefrontdoordoesnotcloseasfirmlyaswhenyourstovewasnew.Thisisduetoanaturalcompressionofthegaskets.Totightentheseal,openthedoorandrotatethehandleonefullturncounterclockwiseorbendthelatchplateonthestove.

blowerTheoptionalbloweronyourTLC2000stoverequiresverylittlemaintenance.Youshould,however,keeptheair inletandthemotorfreeofdustanddirt.

glass - CleaningSometimes itwillbenecessary tocleanaccumulatedashfromtheglasssurface;allowingthisashtoremainontheglassforlongperiodscanresultin“etching”duetotheacidityof theash.Thecreosotewhichaccumulateson theglassshouldburnoffduringyourhotfires.Nevercleantheglasswhileitishot,anddonot useabrasivesubstances. Wash thesurfacewithcoolwater,andrinsethoroughly.Youmaywish to use a non-abrasive cleanerspecificallydesignedforuseonstoveglass.Inanycase,drythoroughlybeforerelightingyourstove.

gasketsGasketsareusedonthedoorsandtoplidoftheTLC2000.Youmustcheckthesegasketsfromtimetotime,andreplacethemwhennecessary.Thegasketsaremadeoffiberglassofdifferentsizes(obtainablefromHarmanDealer)andarefixedinplacewithahightemperaturestovegasketcement.Tochangeagasket,firstremovethewornfiberglassandcleantheareawithawirebrush.Alsocleananyothersurfacesthatcomeintocontactwiththegasket.Placeasmallbeadof cement in the areaunder the gasket, thenpress newgasketmaterialintothechannel;donotoverlaptheends.Seatthegasketfirmlybyapplyingpressurewhenpossible;forexample,afterchangingthedoorgasket,closethedoor.Allowthecementtodrybeforeusingyourstove.

maintenance

Lid Gasket

Door Gasket

Glass Gasket

Ash Door Gasket

Rotate door handle one full turn counter-clockwise to tighten door seal.

15 3-90-08691R17_11/13

Installation

dO NOT INSTAll IN A SlEEPINg rOOm

Assemblyblower (Optional)Bolttheblowertothebottomrearofthestovewithfour1/4-20bolts.Tightenthebolts,butdonotovertighten.Theblowerspeedcanbeadjustedusing theknob that isbuilt-intothepowercord.Whenfirststartingafire,keepthebloweroff.Afteragoodbedofcoalsisestablished,youcanrunthebloweratanyspeeddesired.The power cord for the blowermust be connected to agroundedoutlet,andmustberoutedawayfromtheappliance.

Blower Variable Speed knob

Top Air grill (Optional)The top air grill must be installed before the chimneyconnectorisinstalled.Toinstallsimplyplacethetopairgrillovertheflueout letandpositionasshownatleft.Itisheldinplacebygravity.Thetopairgrillisadecorativeoptionthatdoesnotaddorsubtractfromtheperformanceofthestove.

Top Air Grill

16 3-90-08691R17_11/13

Floor ProtectionIn all installations, the area under and around the stovemustbeprotectedfromfallingashandlivecoals.Thefloorprotectormustbeofnoncombustiblematerial,andpositionedasshownintheaccompanyingillustration.The guidelines for floor protection are: 1. Completelyunderthestoveandanyhorizontalrunsof

connector.Thefloorprotectionmustextendaminimumof2"(51mm)beyondeachsideofthehorizontalconnector;

2. 8"(203mm)toeachsideandtotherearoftheappliance;3. U.S.16"(405mm)infrontofthedoors; Canada18"(457

mm)infrontofthedoors.ClearancesClearanceistheemptyspacerequiredbetweenthestoveorchimneyconnectortothenearestcombustiblesurfaceorobject,suchaswalls,ceilings,floors,orfurniture.ClearancedistancesmayonlybereducedbyusingmethodsapprovedbyeithertheCAN/CSAB365standard(Canada)orNFPA211(U.S.)Contactyourbuildingauthorityforinformationifyouareinterestedinreducingclearancedistancesotherthanthosepresentedhere.

InstallationParallel versus Corner InstallationsAparallelinstallationisoneinwhichthebackandsidesofthestoveareparalleltothewallsbehindandtothesideofthestove.Acornerinstallationisoneinwhichthebackofthestoveispositioneddiagonallyacrossacorneroftheroom.Eachinstallationrequiresitsownsetofclearances.For parallel installations the required clearancedistancesfromthestoveare:18" (457mm) to thesidewalland16"(405mm)tothebackwall.Fromthechimneyconnectortotherearwallmustbe18"(457mm),tothesidewall27"(685mm)andtotheceiling,36"(914mm).Fireplaceinstallationsmustmeetthesesameclearancerequirements;specificallyfollowtheseguidelinesformantelandtrimclearances.For corner installations, the clearance distances fromthestoveare12"(305mm)fromeachcornerof thestovemeasuredstraighttothenearestcombustiblematerial.Fromthefrontofthestove,clearancetocombustiblematerialssuchasfurniture,curtains,fuel,etc.,is:48"(1219mm)intheU.S.and60"(1524mm)inCanada.

Alternate floor protector dimension may be used as long as they satisfy the measurement requirements shown below.Minumum size floor protection for a corner installation hearth pad is 48" x 48" (USA ONLY).

48"

48"

j

g

Floor Protection Requirements Inches Millimeters

Sides-USA/CANADA*

Rear-USA

8203

8305

h Front-USA/CANADA* 16457

CbA

Parallel Installation Inches Millimeters

BackWallToUnit

SideWallToUnit

BackWallToFlueConnector

16406

18457

27685

Floor Protector

Wall

Wall

g g

h

j

A

b

C

FE

Corner Installation Inches Millimeters

WallstoUnitBody

WallstoFlueConnector

12305

18457

Floor Protector

Wall

Wall

E

E

F

F

Floor Protector

17 3-90-08691R17_11/13

The Chimney SystemSoot and Creosote - Formation and Need for removalWhenwood is burned slowly, it produces tar and otherorganic vapors, which combinewith expelledmoistureto form soot or creosote.The soot and creosote vaporscondenseintherelativelycoolchimneyflueofaslowburningfire.Asaresult,sootorcreosoteresidueaccumulatesonthefluelining.Whenignited,thissootorcreosotecanresultinanextremelyhotfire.Thechimneyconnectorandchimneyshouldbeinspectedatleastonceeverytwomonthsduringtheheatingseasontodetermineifasootorcreosotebuild-uphasoccurred.Ifsootorcreosotehasaccumulated(3mmormore)itshouldberemovedtoreducetheriskofachimneyfire.Checking your chimney and chimney connector morefrequently, especiallywhile you are getting used to yourstove,isrecommended.Toinspectthissystem,letthestovecool.Usingaflashlightandmirror,checktheinteriorofthechimneyconnector,andthechimneyitself.Tocleandepositsfromthesurfaceoftheconnector,useastiffwirebrushafterdismantlingtheconnectorassembly.Tocleanthechimney,useaspeciallydesignedbrushsizedtofityourparticularflueopening,orcallanestablishedchimneycleaningservice.At the end of the heating season, perform a thoroughexaminationofyourchimneysystem,andhaveitrepairedifnecessary.draftDraftiswidelymisunderstood.It isimportantthatyou,thestoveoperator,realizethatdraft isavariableeffect,notagivenquantity.Stovesandchimneysdonothavedraft,yetdraftisthekeytoyourstove’sperformance.Draft is a force, producedbyanoperating stoveand thechimneytowhichit isattached.It iscreatedbyhotgasesrisingupthechimney,creatingapressuredifferencebetweenthe insideofyourhomeand theoutsideair. Itcontinuallymovesfreshcombustionairintothestove,andhotexhaustgasesoutof thestove;without thisconstantflow, thefirewillgoout.Other factors, such as barometric pressure, winds, theairtightnessofthehome,thetotal insidechimneyvolume,chimneyheightandthepresenceofventingdevicessuchasexhaustfansalsoplayaroleinmaintaininganadequatedraft.Insomecases,awindowmayneedtobeleftopen,orsomeothersourceoffreshairprovided,tokeeptheapplianceoperatingproperly.Lowbarometricpressures,superinsulatedhomesandexhaustfanscanreducedraft;windscanplayhavocwithdraft;andtoolargeortoosmallachimneyvolumecancausereduceddraftduetotheexcessivecoolingornotenoughroomtoventexhaustgasesquickly.Somesignsofinadequatedraftaresmoking,odor,difficultyinmaintainingthefire,andlowheatoutput.Overdraftcanbecausedbyaverytallchimneyevenifitistherecommendedsize,andcancauseoverfiringof your stove.Signsofanoverdraft include rapid fuel consumption, inability to slowthefire,andpartsofthestoveorchimneyconnectorglowingred.Itisimportantthatyoufollowthechimneyguidelinesinthismanual,includingsize,type,andheighttoavoiddraftproblems.

Chimney SystemWheninstalledandoperatedaccordingtothismanual,theTLC2000willproduceenoughhotgasestokeepthechimneywarmsothatadequatedraft ismaintainedthroughout theburncycle.Chimney ConnectorsIngeneral,followingtheseguidelineswillensurecompliancewithallnationalandprovincialcodes;priortobeginningyourinstallation, checkwith your local building codeofficial tocheckonadditional local regulationswhichmay influencethedesignandplacementofyourventingsystem.TheHarmanTLC2000maybeinstalledwith(150mm)24gaugechimneyconnectorpipe.Sizeoftheconnectorshouldcorrespondtothesizeofthefluecollaropening.Donotusemakeshiftcompromises.No part of the chimney connector may pass through an attic or roof space, closet or other concealed space, or through a floor or ceiling.Wheneverpossible,avoidpassingtheconnectorthroughacombustiblewall; if youmust, use an approvedwall pass-through,describedlaterinthissection.Assembletheconnectorbeginningatthefluecollar,withthecrimpedendspointingtowardsthestove(tokeepdebrisandcreosoteflakesinsidethesystem).Eachjoint,includingtheonetothestove’sfluecollarandtheonetothechimneyitselfshouldbesecuredwithatleastthreesheetmetalscrews.Screwsmaybeamaximumof3inchesapart.A1-1/4"(30mm)overlapisrequiredateachjoint,includingthefluecollarattachment.Nomorethantwo90degreeelbowsshouldbeused,andthetotallengthofconnectorshouldnotexceed10feet(3m).Allhorizontalrunsofconnectormusthaveaminimumupwardslopeof1/4"(6mm)perfoot(20mmpermeter).wall Pass-throughsOccasionallyitisnecessarytopassthechimneyconnectorthroughacombustiblewalltoreachthechimney.Dependingonyourlocalbuildingcodes,andthepertinentprovincialornationalcodes,thereareseveralchoicesforaccomplishingthissafely.Beforebeginningyourinstallation,contactlocalofficials, and also the chimney connector and chimneymanufacturerforspecificrequirements.Canada. Threemethods are approved by theCanadianStandardsAssociation.The diagram shows onemethodrequiringan18"(450mm)airspacebetweentheconnectorandthewall.Itallowsuseofoneortwocoversasdescribedinthediagram.ThetwoothermethodsaredescribedindetailinthecurrentissueofCAN/CSAB365,thenationalstandard.United States IntheU.S.,thenationalcodeisNFPA211.Whilemanylocalitiesadoptthisstandard,besuretocheckwithlocalauthoritiesbeforebeginningyourinstallation.

18 3-90-08691R17_11/13

Chimney System

TheNFPA(NationalFireProtectionAssociation)permitsfourmethodsforpassingthroughacombustiblewall.Acommonlyusedmethodtopassthroughawalldirectlytoamasonrychimneyistoclearaminimum12"(300mm)aroundtheentirechimneyconnector,andfillitwithbrickmasonrywhichisatleast3.5"(90mm)thick.Afireclayliner,minimum3/8"(9mm)wallthicknessmustrunthroughthebrickwalltothechimneyliner(butnotbeyondtheinnersurfaceoftheliner).Itmustbecementedinplacewithrefractorycement.Thismethodisillustrated.Fordetailsontheotherthreeoptions,refertothemostrecenteditionoftheNFPA211code.The ChimneyTheTLC2000mustbeinstalledintoachimneyapprovedforusewithsolid-fuelappliances.IntheU.S.,theTLC2000mustbeconnectedto(1)aprefabricatedchimneycomplyingwiththerequirementsforTypeHTchimneysintheStandardforChimneys,Factory-Built,ResidentialTypeandBuildingHeatingAppliances,UL103,or(2)acode-approvedmasonrychimneywithaflueliner.InCanada,theTLC2000islistedforusewithprefabricatedchimneystestedandlistedtothehightemperature(650degreesC)chimneystandard,ULCS-629,orwithacodeapprovedmasonrychimney.Theminimumrecommendedheightforanychimneyis16ft(4.8m)abovefluecollarheight.Aroundflue(eithermasonryorapprovedprefabricated),ofeither6"(150mm),7"(180mm)or8"(200mm)maybeused.Forsquareorrectangularmasonrychimneys,nominalsizesof8"x8"or8"x12"(200mmx200mm,200mmx300mm)maybeused.

More than 10 Ft. (3 m)

10 Ft. (3 m)

2 Ft. (.6 m) Min

Height necessary above any roof surface within 10 Ft. (3 m)

3 Ft. (.9 m) minimum above exit point

Ridge

Chimney

The3-foot,2-foot,10footrule

Codesrequirethatsolid-fuelchimneysextend3ft(0.9m)abovethepointatwhichtheyexitfromtheroof,providedthatnopartofanystructureiswithinthetopofthechimney,thenthechimneymustextend2ft(6m)abovethehighestpointwiththe10ft(3m)radiustopheight.Ifthereisnottenfeetofclearancefromthetopofthechimney,thenthechimneymustextend2ft(6m)abovethehighestpointwiththe10ft(3m)radius.

Hole with minimum clearance of 18” (450mm) Between connector and wall.

Non-combustible cover, one side only. If two covers are used, each must be mounted on non-combustible spacers at least 7/8” (21mm) away from the wall.

1” (25mm)Clearance

AN APPROVED CANADIAN WALL PASS-THROUGH

AN APPROVED U.S. WALL PASS-THROUGH

Minimum 2” (50mm)Clearance to Brick

Liner Minimum 12” (50mm) to Brick

Fire Clay Thimble

Chimney ConnectorC

him

ney

Flue

Masonry Chimney Built to NFPA 211 Specifications

Closest Combustible Material

Minimum 12” (300) to Combustibles

AN APPrOvEd CANAdIAN wAll PASS-ThrOugh AN APPrOvEd u.S wAll PASS-ThrOugh

19 3-90-08691R17_11/13

Chimney System

Installing to a Prefabricated ChimneyWhenventingyourTLC2000usingaprefabricatedchimney,be sure to contact local building codeauthorities, and tofollow themanufacturer’s instructionsexactly. Use onlythemanufacturer’sparts;donotusemakeshiftinstallationtechniques. Allprefabricatedchimneysmustbe tested toeithertheU.S.orCanadianhigh-temperaturestandards,UL103orULC-629.

dO NOT CONNECT ThIS uNIT TO A ChImNEY FluE SErvINg ANOThEr APPlIANCE.Existing masonry ChimneysIfyouplanonusingapre-existingmasonrychimney,haveitthoroughlyinspectedandcleaned.Anyfaultswhichmakethechimneyunsafeandunusablemustberepairedpriortouse.Thesecanincludeimproperheight,structuraldefects,blockages,inadequateclearancetocombustibles,unsealedopeningsintootherroomsofthehouse,signsofcreosoteorsmokeleakage,alooseorabsentclean-outdoor,orabsenceofaliner.dO NOT CONNECT TO ANY AIr dISTrIbuTION duCT Or SYSTEmventing to a masonry ChimneyWhenconnectingtoamasonrychimney,severalprovisionsarestandard.First,whetherthechimneyconnectorisventedtothechimneythroughathimbleorabreechpipe,neithermustpassbeyond the innersurfaceof thechimney liner,andbothmustbefirmlycementedinplacewithrefractorycement. (A thimble is amasonry pipewhich is insertedthrough the chimneywall, and is frequently thepreferredmethod;abreechpipeisapieceofsteelpipeusedthesameway.)InCanada,abreechpipehasridgesorprotrusionstolockitfirmlyintotherefractorycement.Ineithercase,thechimneyconnectorventstothechimneythroughthethimbleorbreechpipe.Usingathimble,theconnectorslidescompletelyinsidethemasonrytotheinneredgeoftheflueliner,andmaybeeasilyremoved for chimneyandconnector inspection.Abreechpipemustextendatleast2"(50mm)intotheroom,sotheconnectorcanbeattachedwithsheetmetalscrews.venting to a masonry Fireplace ChimneyInsomesituations,acodecompliantchimneyoriginallyusedfor amasonry fireplacemaybeused to install yourTLC2000.Inadditiontotherequirementsfoundinthepreviousparagraphs,it isimportanttobeawarethatallclearancesmustbemet,includingthosefromthechimneyconnectortocombustibles—18"(360mm)tosidesand18"(450mm)toceiling.Donot forget to includefloorprotection inyourplans.(SeeClearancesandFloorProtectioninthissection.)Sincemanyfireplaceshaveexposedwoodenmantelsandtrim,payspecialattention to theclearancesnecessary tothesematerials.Ifyourfireplacechimneyisbehindacombustiblewall,youmust use an approvedwall pass-through system to gainaccess to themasonry chimney.The chimney connectormust enter the chimneyat a placewhere it is lined, andthefireplacemustbemade inoperable.Forexample,youmightremovethedamper,replacingitwithasecure,airtight,noncombustible seal (removable for inspection); this alsosatisfiestherequirementthatnoroomairmustbeallowedtoenterthechimney.

TheHarmanTLC2000wastestedwiththefueldooropenandclosed.If you operatewith the door open, be sure to install theoptionalfirescreen,andbesurethecleanoutcoverabovethefireboxisremoved.Do not burn any fuel other than those specified.Othersolidfuels,suchascharcoal,cancauseincreasedcarbonmonoxideproductionoroverfiring.Neverusehighlyvolatilesubstances in your stove, suchas gasoline,which couldcauseanexplosion.When solid fuels are burned completely, they producewaterandcarbondioxide.However, in longslowburns,asubstantialamountofcarbonmonoxidemaybeproduced.Ifallowedtobuildup,carbonmonoxide(whichisodorless)canprovefatallypoisonous.Properventilationanddraftwillprevent this fromhappening. If yousmell smoke, turnuptheair control leversetting,and thoroughlyventilateyourdwelling.During future burns, be careful not to overloadthestovewithfuel,soyouwillnotbetemptedtoconstantlyoperateatalowaircontrolsetting.Othercausesofpoorventilationordraftareicing,exhaustfans,ablockedoutsideairinlet,androomairstarvation.Ifyourstoveissluggishandyougetoccasionalodor,checkthesepossibilitiesandincreasetheairflowinyourhome.

WARNING!dO NOT INSTAll IN SlEEPINg rOOm.

Chimney Connector

Clay thimble, reaching just to the inside of the chimney liner

Mechanical fasteners (minimum 3) but not at the bottom of the connector

Chimney liner inner edges

High-temperature sealant used to cement the clay thimble

Service Parts

beginning manufacturing date: N/A Ending manufacturing date: Active

TlC-2000

Part number list on following page.

Top load Coal/wood Stove

1-70-08690-4 (metallic blue) Ending manufacturing date jan 20101-70-08690-5 (honey glo) Ending manufacturing date june 20091-70-08690-10 (mojave red) Ending manufacturing date jan 20101-70-08690-12 (Forest green) Ending manufacturing date jan 2010

1

14

32

45

622

21

7

8

9

16

18

12

13

15

1011

2019

17

1-90-08690-1 (black w/door)

1-70-08690-1 (black) Ending manufacturing date: june 20111-70-08690-2 (Charcoal) Ending manufacturing date: june 2011 1-70-08690-3 (goldenfi re) Ending manufacturing date: june 2011

retired units

08/13

Service Parts

beginning manufacturing date: N/A Ending manufacturing date: Active

TlC-2000

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer ordistributor.hearth and home Technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

Stockedat depot

ITEm dESCrIPTION COmmENTS PArT NumbEr1 TopAirGrillAssembly(Option) 1-00-087102 Top,Rear 2-00-852109L3 TopLoadDoorAssembly 1-10-08720A4 Gasket,Bulbblack1-1/2”X9-32w/psa(topplate) 31/2Ft 1-00-10025 Y5 GasketPlatew/gasket 1-10-08759A6 DamperLinkageArmWeldmentw/Knob 1-10-08722 Y

7WoodenKnob(damperhandle),2Sets Pre008850439 1-00-05228 YWoodenKnobw/Bolt,2Sets Post008850439 1-00-06228

8 Shield,leftside 2-00-852139P Y9 Shakerhandleweldment 1-10-852166 Y10 Bloweroption-includes3speedcontrol 1-00-08643 Y11 Grate,long15in-cast Qty2req 3-00-00208 Y12 Gratelink 2-00-852119 Y13 Brick9”X4-1/2”x1-1/4” Pkgof7 1-00-900450125 Y14 BrickSupports 1Set 1-00-087245615 AshDoorAssembly 1-10-08718A

AshDoorLatchHardware 1-00-85223 Y16 AirslideKnob Pkgof3 3-40-08746-317 AshPan 1-10-08690 Y18 AshLipTrim Gold 3-43-4722386

19DoorKitAssembly BlackClassic 1-00-08711-1DoorKitAssembly(Gold) No longer available 1-00-08711-4

DoorFrame-Roped Cast 4-00-05165DoorFrame-Roped(Gold) No longer available 1-10-05165GlassClipsandScrews 2-00-05202-4 YGlassRect12-7/16”X17-5/8” 3-40-08214 Y

20CoalBars Setof3 1-00-852145CoalBarHolders Setof2 1-00-852146

21 Shield,rightside 2-00-852141P Y22 Cleanout,TLC 2-00-852153 Y

Additionalservicepartnumbersappearonfollowingpage.

Service Parts

beginning manufacturing date: N/A Ending manufacturing date: Active

TlC-2000

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer ordistributor.hearth and home Technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

Stockedat depot

ITEm dESCrIPTION COmmENTS PArT NumbErAirAdjuster,LeftandRight 1Set 1-00-852140AirGrillTrim 3-43-08725Bolt(ashdoorhinge) 2-00-06952BBrassElbow 3-40-00121BrickBacker Qty2req 2-00-852147 YBrick,Fullskid 414Pcs 3-40-900450-414BronzeBushing Post008860016 3-31-852177Bushing,SteelSleeve,3/8ODx1/2OAL 3-50-05229CastDoor,Roped 1-10-08159ACastPawl 3-00-453002 YCookinggrill-Option(w/handle) 1-00-08709Cozyscreen 3-40-727336Dowelpin1/4X3/8 Pkgof15 3-30-2019-15Gasket1/2”roundrope(Frontloaddoor) 20Ft 1-00-1086204 YGasketGlue,32oz 3-42-4583Gasket,Roundblack1/4”w/psa(glass) 15Ft 1-00-2312 YGasket,Roundwhiteld5/8”(ashdoor) 1-00-10000 YHandle,CookingGrill 2-00-852169LHeatShield 2-00-852160BHinge,Rear Qty2req 2-00-852129LLoadDoorHandlew/Bolt 1-00-00247 YLoadDoorHandle&Hardware Pre008860001 1-00-08176 YPawBolt(oldstyle) 4-31-08055 YPawlRetrofit 1-00-453001 YPowerCord 3-20-29685 YScrew,#10-24x3/8”AlloySteelBlackOxideButtonHeadCap Pkgof100 3-30-3011-100 YScrew,1/4”-20x21/2”PhillipsRoundHeadZincPltdMachine Pkgof25 3-30-6007-25 YShakerBarWeldment 1-10-08717 Y

ShakerReplacementKitPre008860016 1-00-852016 YPost008860016 1-00-852172

ShakerShaft 3-50-03373 YSpringWasher-plated6mm Pkgof25 3-31-08558-25TopLiftArm 2-00-852128PTouchUpPaint,Aerosol Black 3-42-1990VariableSpeedControlw/off 3-20-02223WoodenHandle,frontdoor 1-00-00122 YWoodenHandle,LoadDoor 3-40-00247 Y

4021-645F02-18-13 Page1of2

hearth & home TechnologieslImITEd lIFETImE wArrANTY

Hearth&HomeTechnologies,onbehalfofitshearthbrands(”HHT”),extendsthefollowingwarrantyforHHTgas,wood,pellet,coalandelectrichearthappliancesthatarepurchasedfromanHHTauthorizeddealer.

wArrANTY COvErAgE:HHTwarrantstotheoriginalowneroftheHHTapplianceatthesiteofinstallation,andtoanytransfereetakingownershipoftheapplianceatthesiteofinstallationwithintwoyearsfollowingthedateoforiginalpurchase,thattheHHTappliancewillbefreefromdefectsinmaterialsandworkmanshipatthetimeofmanufacture.Afterinstallation,ifcoveredcompo-nentsmanufacturedbyHHTarefoundtobedefectiveinmaterialsorworkmanshipduringtheapplicablewarrantyperiod,HHTwill,atitsoption,repairorreplacethecoveredcomponents.HHT,atitsowndiscretion,mayfullydischargeallofitsobligationsundersuchwarrantiesbyreplacingtheproductitselforrefundingtheverifiedpurchasepriceoftheproductitself.Themaximumamountrecoverableunderthiswarrantyislimitedtothepurchasepriceoftheproduct.Thiswarrantyissubjecttoconditions,exclusionsandlimitationsasdescribedbelow.

wArrANTY PErIOd:Warrantycoveragebeginsonthedateoforiginalpurchase.Inthecaseofnewhomeconstruction,warrantycoveragebeginsonthedateoffirstoccupancyofthedwellingorsixmonthsafterthesaleoftheproductbyanindependent,authorizedHHTdealer/distributor,whicheveroccursearlier.Thewarrantyshallcommencenolaterthan24monthsfollowingthedateofproductshipmentfromHHT,regardlessoftheinstallationoroccupancydate.Thewarrantyperiodforpartsandlaborforcoveredcomponentsisproducedinthefollowingtable.Theterm“LimitedLifetime”inthetablebelowisdefinedas:20yearsfromthebeginningdateofwarrantycoverageforgasappliances,and10yearsfromthebeginningdateofwarrantycoverageforwood,pellet,andcoalappliances.Thesetimeperiodsreflecttheminimumexpectedusefullivesofthedesignatedcomponentsundernormaloperatingconditions.

Seeconditions,exclusions,andlimitationsonnextpage.

Parts Labor Gas Wood Pellet EPAWood Coal Electric Venting

X X X X X X X

AllpartsandmaterialexceptascoveredbyConditions,

Exclusions,andLimitationslisted

X X X Igniters,electroniccomponents,andglass

X X X X X Factory-installedblowersX Moldedrefractorypanels

X Firepotsandburnpots

5years 1year X X Castingsandbaffles

7years 3years X X X Manifoldtubes,HHTchimneyandtermination

10years 1year X Burners,logsandrefractory

LimitedLifetime 3years X X X X X Fireboxandheatexchanger

X X X X X X X Allreplacementpartsbeyondwarrantyperiod

WarrantyPeriod HHTManufacturedAppliancesandVenting

1Year

ComponentsCovered

3years

2years

90Days

3-90-08691R17_11/13

4021-645F02-18-13 Page2of2

wArrANTY CONdITIONS:• ThiswarrantyonlycoversHHTappliancesthatarepurchasedthroughanHHTauthorizeddealerordistributor.Alistof

HHTauthorizeddealersisavailableontheHHTbrandedwebsites.• ThiswarrantyisonlyvalidwhiletheHHTapplianceremainsatthesiteoforiginalinstallation.•ThiswarrantyisonlyvalidinthecountryinwhichtheHHTauthorizeddealerordistributorthatsoldtheappliance

resides.• Contactyourinstallingdealerforwarrantyservice.Iftheinstallingdealerisunabletoprovidenecessaryparts,contact

thenearestHHTauthorizeddealerorsupplier.Additionalservicefeesmayapplyifyouareseekingwarrantyservicefromadealerotherthanthedealerfromwhomyouoriginallypurchasedtheproduct.

• Checkwithyourdealerinadvanceforanycoststoyouwhenarrangingawarrantycall.Travelandshippingchargesforpartsarenotcoveredbythiswarranty.

This warranty is void if:• Theappliancehasbeenover-firedoroperatedinatmospherescontaminatedbychlorine,fluorine,orotherdamaging

chemicals.Over-firingcanbeidentifiedby,butnotlimitedto,warpedplatesortubes,rustcoloredcastiron,bubbling,crackinganddiscolorationofsteelorenamelfinishes.

• Theapplianceissubjectedtoprolongedperiodsofdampnessorcondensation.• Thereisanydamagetotheapplianceorothercomponentsduetowaterorweatherdamagewhichistheresultof,but

notlimitedto,improperchimneyorventinginstallation.

lImITATIONS OF lIAbIlITY:• Theowner’sexclusiveremedyandHHT’ssoleobligationunderthiswarranty,underanyotherwarranty,expressor

implied,orincontract,tortorotherwise,shallbelimitedtoreplacement,repair,orrefund,asspecifiedabove.InnoeventwillHHTbeliableforanyincidentalorconsequentialdamagescausedbydefectsintheappliance.Somestatesdonotallowexclusionsorlimitationofincidentalorconsequentialdamages,sotheselimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificrights;youmayalsohaveotherrights,whichvaryfromstatetostate.EXCEPTTOTHEEXTENTPROVIDEDBYLAW,HHTMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYSPECIFIEDHEREIN.THEDURATIONOFANYIMPLIEDWARRANTYISLIMITEDTODURATIONOFTHEEXPRESSEDWARRANTYSPECIFIEDABOVE.

wArrANTY ExCluSIONS:Thiswarrantydoesnotcoverthefollowing:• Changesinsurfacefinishesasaresultofnormaluse.Asaheatingappliance,somechangesincolorofinteriorand

exteriorsurfacefinishesmayoccur.Thisisnotaflawandisnotcoveredunderwarranty.• Damagetoprinted,plated,orenameledsurfacescausedbyfingerprints,accidents,misuse,scratches,melteditems,

orotherexternalsourcesandresiduesleftontheplatedsurfacesfromtheuseofabrasivecleanersorpolishes.• Repairorreplacementofpartsthataresubjecttonormalwearandtearduringthewarrantyperiod.Theseparts

include:paint,wood,pelletandcoalgaskets,firebricks,grates,flameguides,batteriesandthediscolorationofglass.• Minorexpansion,contraction,ormovementofcertainpartscausingnoise.Theseconditionsarenormalandcom-

plaintsrelatedtothisnoisearenotcoveredbythiswarranty.• Damagesresultingfrom:(1)failuretoinstall,operate,ormaintaintheapplianceinaccordancewiththeinstallation

instructions,operatinginstructions,andlistingagentidentificationlabelfurnishedwiththeappliance;(2)failuretoinstalltheapplianceinaccordancewithlocalbuildingcodes;(3)shippingorimproperhandling;(4)improperopera-tion,abuse,misuse,continuedoperationwithdamaged,corrodedorfailedcomponents,accident,orimproperly/incorrectlyperformedrepairs;(5)environmentalconditions,inadequateventilation,negativepressure,ordraftingcausedbytightlysealedconstructions,insufficientmake-upairsupply,orhandlingdevicessuchasexhaustfansorforcedairfurnacesorothersuchcauses;(6)useoffuelsotherthanthosespecifiedintheoperatinginstructions;(7)installationoruseofcomponentsnotsuppliedwiththeapplianceoranyothercomponentsnotexpresslyauthorizedandapprovedbyHHT;(8)modificationoftheappliancenotexpresslyauthorizedandapprovedbyHHTinwriting;and/or(9)interruptionsorfluctuationsofelectricalpowersupplytotheappliance.

• Non-HHTventingcomponents,hearthcomponentsorotheraccessoriesusedinconjunctionwiththeappliance.• Anypartofapre-existingfireplacesysteminwhichaninsertoradecorativegasapplianceisinstalled.• HHT’sobligationunderthiswarrantydoesnotextendtotheappliance’scapabilitytoheatthedesiredspace.Informa-

tionisprovidedtoassisttheconsumerandthedealerinselectingtheproperappliancefortheapplication.Consider-ationmustbegiventoappliancelocationandconfiguration,environmentalconditions,insulationandairtightnessofthestructure.

25

Service & maintenance log

Date Of Service Performed By Description Of Service

3-90-08691R17_11/13

Proudly Printed On 100% Recycled Paper

At Harman, we build each product to a standard, not a price.

(Signature of Boxer)

Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA.