Installation of new MPR

13
Installation of new MPR Harald Lück ILIAS WP1 meeting, June 14th 2005

description

Installation of new MPR. Harald Lück ILIAS WP1 meeting, June 14th 2005. Old MPR: T=1.35%. New MPR: T ≈ 900ppm. Timeline of MPR exchange. 02.05: Opened vacuum vessel & exchanged MPR 03.05: Installed attenuator. Prealigned MPR ….spent some time with aligning 09.05 Ifo aligned and flashing - PowerPoint PPT Presentation

Transcript of Installation of new MPR

Page 1: Installation of new MPR

Installation of new MPR

Harald Lück

ILIAS WP1 meeting, June 14th 2005

Page 2: Installation of new MPR

Old MPR: T=1.35%

New MPR: T≈ 900ppm

Page 3: Installation of new MPR

Timeline of MPR exchange

• 02.05: Opened vacuum vessel & exchanged MPR

• 03.05: Installed attenuator. Prealigned MPR• ….spent some time with aligning• 09.05 Ifo aligned and flashing• 12.05 stable PR Michelson lock• 19.05 1hour 2f lock @ 3.5kHz• 22.05 tuned down to 1kHz

Page 4: Installation of new MPR

Power in PR Cavity

• Input power: 1.7W incident to MPR.

• Old MPR (1.35%) ≈ 500W ≈ 1.7 * 4/ 1.35%

• New MPR: up to 2kW (normally ~1.5kW)

• Expected PR factor >2000 ↔ 3.4kW

• Have not yet determined where we lose the power (→Stefan)

Page 5: Installation of new MPR

Power measurements

• Power transmitted through mirrors– MFE: 13mW/10ppm → 1.3kW– MFN: 11mW/10ppm → 1.1W

10ppm for MFN guessed to be the same as MFE

– BS AR ca. 30mW/44ppm → 1.4kW– MCN, MCE very high losses due to lens

Page 6: Installation of new MPR

Cavity pole measurement

Curve fit gives: 15.14 Hz +-0.15 HzSimulations with 126ppm transm. for MCE/N, 50ppm for MFE/N, and 200ppm for BS/AR.BS thermal lens set to 10k for new configurations give a pole f of 15 Hz.

Page 7: Installation of new MPR

Simulations

Fit pole freq: 141Hz ----------------------------------------------------------- pole freq: 18.4 Hz------------------------------------------------------------ pole freq: 15.0 Hz

Page 8: Installation of new MPR

Transfer function with old MPR (1.35%)

Fit gives 147Hz pole frequency

Page 9: Installation of new MPR

Wire attenuator, 15µm glas fibre, 0.3% attenuation/round tripNot needed with the present losses

Page 10: Installation of new MPR

Wire attenuator in front of MPRr

Page 11: Installation of new MPR

Thermal lensing in BSoutput mode pattern

Directly after relocking

f=20km

A few minutes after relocking

f= 8km

Page 12: Installation of new MPR

Building up the thermal lensdark port power after relocking for PR and DR Michelson

0 10 20 30 40 50 60 70 80 90 1000

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

Time (secs)

Am

pli

tud

e (V

)

DR MIDVIS

PR MIDV

IS

Page 13: Installation of new MPR

Increasing ROC heater powerdual recycled lock, 1kHz detuned

0 0.5 1 1.5 2 2.5 33

3.5

4

4.5

Time (Hours)

Am

pli

tud

e (V

-rm

s)

SPOTPOS:MCE:SUMfs = 1 : 2005-06-01 10:59:47

0 0.5 1 1.5 2 2.5 32.5

3

3.5

4

Time (Hours)

Am

pli

tud

e (V

-rm

s) SPOTPOS:MCN:SUMfs = 1 : 2005-06-01 10:59:47

0 0.5 1 1.5 2 2.5 3

-4

-3.5

-3

Time (Hours)

Am

pli

tud

e (V

-rm

s)

SPOTPOS:MFE:SUMfs = 1 : 2005-06-01 10:59:47

0 0.5 1 1.5 2 2.5 3-4

-3.5

-3

-2.5

Time (Hours)

Am

pli

tud

e (V

-rm

s)

SPOTPOS:MFN:SUMfs = 1 : 2005-06-01 10:59:47

0.5 1 1.5 2 2.51.2

1.3

1.4

1.5

1.6

1.7

1.8

1.9

Time (Hours)

Am

pli

tud

e (V

-rm

s)

AAMI:SCAN:DENOMfs = 1 : 2005-06-01 10:59:47Dark port power

PR cavity power

75W 80W 85W 90W 98W