INSTALLATION INSTRUCTIONS WALL HUNG …...The wall, or whatever material the screws are attached to,...
Transcript of INSTALLATION INSTRUCTIONS WALL HUNG …...The wall, or whatever material the screws are attached to,...
![Page 1: INSTALLATION INSTRUCTIONS WALL HUNG …...The wall, or whatever material the screws are attached to, must be of sufficient strength to fully support the lavatory. It may be necessary](https://reader035.fdocuments.in/reader035/viewer/2022071105/5fdf3e630ff2406cda2ff5fc/html5/thumbnails/1.jpg)
Thank you for selecting the Crane Plumbing wall hung lavatory. To insure this product is installed properly, pleaseread these instructions carefully before you begin. This high quality, vitreous china fixture is meant to provide manyyears of service, but can be damaged by improper handling and/or installation. Be sure your installation conformsto local codes.
INSTALLATION INSTRUCTIONSWALL HUNG LAVATORIES
Unpack the lavatory.Take a moment to check thefixture to make sure there is no damage. Verify thatyou have all the necessary tools, fittings, andconnection hardware to complete the installation.
1
2
PRE INSTALLATION
3
FinishedFloor
HangerLocationC-L of 2 x 6 Support
(If Needed)
A lavatory is heavy. Provide suitable structural supportbehind the finished wall for the hanger lag screws.
The wall, or whatever material the screws areattached to, must be of sufficient strength to fullysupport the lavatory.
It may be necessary to install a 2 x 6 board behindthe finished wall. Position the board between twostuds so the front surface of the board is flush withthe front of the studs. The finished wall is then appliedover the board.
Certain lavatories have two (2) holes at the backplate for the placement of additional anchor screws.The solid structure of the wall must be present inorder to place anchor screws through these holes.
INSTALLATION
Figure 1
Dimension fromfloor to C-L ofhanger screws
31”Top of Rim
A
WaterSupplies
WasteFinishedFloor
Back PlateAnchorScrewHoles **
Model Dimension “A”1300 3/4”131813201377
1-1/2”
1412 1”
46564658
3/4”
Refer to the chart in Figure 2 to determine theplacement of the lavatory hanger. A typical lavatoryrim height above the floor is 31” Residentialand 34” ADA Maximum.
Dimension “A” indicates the center of the hangermounting screws. Measure and then use a level todraw a plumb line for the screws.
Holes not present on all lavatories.
Hold the steel hanger against the wall markingsure it is centered over the waste outlet hole.
Align the hanger so the plumb line for the screwsis centered in the slots. Mark the locations on thewall.
Drill pilot holes for the hanger. Certain lavatoriesare shipped with steel hangers that a somewhatdifferent than the one illustrated. All hangers shouldbe mounted using the slots rather than the holesin order to provide adjustment if required.
Figure 2
(Residential)
31”Top of Rim
(34” ADA max.)
4642 1-1/8”
*
***
**
Indicates lavatory uses Uni-lox HangerR
4556
1-1/4”
![Page 2: INSTALLATION INSTRUCTIONS WALL HUNG …...The wall, or whatever material the screws are attached to, must be of sufficient strength to fully support the lavatory. It may be necessary](https://reader035.fdocuments.in/reader035/viewer/2022071105/5fdf3e630ff2406cda2ff5fc/html5/thumbnails/2.jpg)
Subject to the “Exclusions” set forth below, CR/PLpromises to the consumer to repair, or at the optionof CR/PL, to replace any part of this plumbing productwhich proves to be defective in workmanship ormaterials under normal use for five years from thedate of purchase. All costs of removal, transportationand reinstallation to obtain warranty service shall bepaid by the consumer. During this five year period,CR/PL will provide, subject to the “Exclusions” sectionset forth below, all parts free of charge, necessaryto correct such defects if this plumbing product hasbeen installed and maintained in accordance withwritten instructions furnished by CR/PL with thisplumbing product.
Exclusions: CR/PL PRODUCTS SHALL NOT BELIABLE FOR INCIDENTAL OR CONSEQUENTIALDAMAGES, INCLUDING COSTS OF INSTALLATION
OR WATER DAMAGE, OR FOR DAMAGESRESULTING FROM ABUSE OR MISUSE OR FROMFAILURE TO INSTALL OR MAINTAIN THISPLUMBING PRODUCT IN ACCORDANCE WITHTHE WRITTEN INSTRUCTIONS FURNISHED BYCR/PL PRODUCTS. USE OF CLEANINGP R O D U C T S C O N TA I N I N G C A L C I U MHYPOCHLORITE (CHLORINE) SHALL CONSTITUTEIMPROPER MAINTENANCE. SOME STATES DONOT ALLOW THE EXCLUSION OR LIMITATION OFINCIDENTAL OR CONSEQUENTIAL DAMAGES, SOTHE ABOVE LIMITATION MAY NOT APPLY TO THECONSUMER. THE ONLY WARRANTY MADE BYCR/PL PRODUCTS IS SET FORTH ABOVE ANDALL IMPLIED WARRANTIES WHICH MIGHT ARISE,INCLUDING THE IMPLIED WARRANTIES OFMERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ARE HEREBYEXCLUDED.Warranty Service: In order to obtain warrantyservice or adjustments, contact the builder, dealeror plumber from whom the product waspurchased, or the Customer Service Department,CR/PL Products, 201 East Fifth Street, Mansfield,OH 44901 (419/522-4211). In obtaining warrantyservice, all transportation, shipping and freightcharges connected with transporting any part ofthis plumbing product must be prepaid by theconsumer. It is the responsibility of the consumerto establish the warranty period by verifying theoriginal purchase date. A bill of sale, cancelledcheck or some other appropriate payment recordmay be kept for this purpose. This warranty givesgives you specific legal rights. You may also haveother rights which vary from state to state.
Limited Five Year Warranty
4
CR/PL 1235 Hartrey Avenue Evanston, IL. 60202
FORM NO: 2068 Revised: 5/22/02. PRINTED IN U.S.A.
WallStud
LavatoryHanger
Lag Screw(Optional) 2 x 6
(Or Equivalentif Needed)
Figure 5
5 Place the lavatory on the wall hanger, making sureits rear lip is securely engaged with the hanger andthat it is centered on the hanger. The lavatory may beleveled by loosening the left hanger screw and raisingor lowering the left side of the hanger. When lavatoryis level, tighten both hanger screws.
6
Connect and tighten the water supply fittings, wastepiping, and pop up. (See Figure 5)
8
Anchor the lower back of the lavatory to the wall withtwo (2) screws / anchor bolts through the right and leftmounting holes through the china. (Not applicable forall lavatory models.) See Figure 3.
The Uni-Lox hanger has tabs that support the undersideof the lavatory. Toggle bolts with washers must beinstalled though these tabs into the lavatory to properlysecure the lavatory.
This fixture is virtually maintenance free. Clean it withany non-abrasive household cleaner and a soft cloth.Avoid striking it with metal objects, as they tend to marthe surface. These marks, or heavy soil, can be removedwith a soft cleaner meant for glazed surfaces.
HangerScrews
Put the hanger in place and secure it with the screws.Check to see that the hanger is level before tighteninginto position.
Figure 3
*17-7/8” Residential20-7/8” ADA (max.)
31” Residential34” ADA (max.)
C-L of HangerSee Detail 131”
4
Support
Top of sink rim
423”
Hanger Detail
FinishedWall
Figure 47 The 1373 CORNATE corner lavatory is hung from the
wall with two (2) smaller hangers. As with other lavatories,there must be suitable support behind the finished wallfor the hanger screws. As illustrated in Figure 4 thelavatory is hung in the corner with one hanger on eachwall. Once the proper hanger height above the floor hasbeen determined, fasten each hanger to the supportswith two lag screws per hanger.
NOTE: Suggested Dimension-Variable depending upon type of supply and waste*
Water SuppliesWaste
R
CAUTION: Install fasteners in china snugly. Do Not overtighten as this can crack the china.
Install toggle boltswith washers whenusing the Uni-LoxHanger Uni-Lox
HangerR
R