InstructionSheet www.prescolite.com • Prescolite TollFree Technical Support 1.888.PRS.4TEC Hours: 8am - 5pm ET 701 Millennium Boulevard • Greenville, SC 29607 With representatives offices in principal cities throughout North America. Copyright 2015, 6/8/15, All Rights Reserved - Printed in U.S.A. Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93001353 INSTALLATION INSTRUCTIONS CAT. NO. D4 Reflector Adjustable Mounting Bracket CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY AND PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING. SAVE THESE INSTRUCTIONS. 1. Bend brackets as shown in Detail “A”. Install the fixture in the ceiling using mounting channels or bar hangers (B6, B24, or by others) placed in the adjustable mounting brackets. Mount the fixture in the ceiling so that the weight of the fixture is supported by the mounting channel or bar and/or hanger wires secured to the building structure. 2. Adjust the fixture so the bottom edge of the plaster flange opening is flush with the finished ceiling line and in alignment with adjacent fixtures. Secure mounting brackets by tightening wing nuts on either side of the fixture. 3. Remove and discard the wire twist around the J-Box covers. Remove J-Box cover plate. Remove appropriate knockout and assemble certified conduit connector for the supply wire used. Connect supply ground wire to fixture ground wire. Connect common supply wire to white fixture wire. Connect 120V or 277V supply wire to the respec- tive 120V or 277V fixture wire. Use certified wire nuts. Reinstall J-Box cover. WARNING: DO NOT pinch wires between J-Box/ballast cover and J-Box. Consult a Qualified Electrician for all other options that require other wiring configurations. 4. Install reflector after all ceiling installation and finishing work is complete. Insert sides of heatsink spring into reflector neck clearance slots, then twist heatsink and push down until desired position on the reflector is obtained. Align heatsink spring with appropriate reflector slots. Heatsink will lock into place, but may be readjusted by twisting and sliding the heatsink into another position. Do NOT use the reflector neck clearance slots as a final installation position for the heatsink. 5. Push reflector into the plaster flange until the reflector is flush against the ceiling. 6. Install the proper lamps (by others). 7. For housing CAT. NO. D4MR, install a lamp marked “Suitable for use in open luminaires” unless used in combination with Prescolite CAT. NO. 2MLH. 8. To install the accessory CAT. NO. 2MLH, first have the reflector installed in the housing. Separate the halves of 2MLH by twisting them apart. Remove the lens retainer wire. Place the maximum quantity of two (2) optical accessories and the MR16 lamp into the bottom half of 2MLH. Replace the lens retainer wire over the edge of the MR16 lamp. Combine the halves of 2MLH by twisting them together. Finally, insert the MR16 lamp pins into the Leviton MR16 lampholder. Replace removable parts after servicing. Wing Nut NOTE: Brackets are supplied flat. To ensure proper alignment, bend brack- ets in line with marks on flange as shown in Detail A. DETAIL A 2MLH J-Box Transformer/ Ballast Plate Bend Brackets in Line with Marks on Flange. NOTE: Remove (3) Grip Clip Springs before installing a Wallwash Trim. Heatsink Plaster Flange J-Box Cover IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, d n a y l p p u s r e w o p o t g n i r i w e r o f e B . s e s a g r o s r o p a v e l b i t s u b m o c o t t c e j b u s s a e r a n i l l a t s n i t o n o D . g n i p m a l r e p o r p d n a during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard. Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition. WARNING - This product contains chemicals known to the State of California to cause cancer, birth defects and/or other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product. See Label for Lamp Positioning: Heatsink Spring Media Holder Bottom Lens Retainer Ring Media Holder Top Page 1 of 2

Transcript of INSTALLATION INSTRUCTIONS CAT. NO. D4 - … · certified conduit connector for the supply wire...

InstructionSheet

ww

w.prescolite.com

• Prescolite TollFree Technical S

upport 1.888.PRS.4TEC

• Hours: 8am

- 5pm E

T

701 Millennium Boulevard • Greenville, SC 29607 With representatives offices in principal cities throughout North America.Copyright 2015, 6/8/15, All Rights Reserved - Printed in U.S.A.

Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93001353

INSTALLATION INSTRUCTIONSCAT. NO. D4

Reflector

Adjustable Mounting Bracket

CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY AND PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.

SAVE THESE INSTRUCTIONS.

1. Bend brackets as shown in Detail “A”. Install the fixture in the ceiling using mounting channels or bar hangers (B6, B24, or by others) placed in the adjustable mounting brackets. Mount the fixture in the ceiling so that the weight of the fixture is supported by the mounting channel or bar and/or hanger wires secured to the building structure.

2. Adjust the fixture so the bottom edge of the plaster flange opening is flush with the finished ceiling line and in alignment with adjacent fixtures. Secure mounting brackets by tightening wing nuts on either side of the fixture.

3. Remove and discard the wire twist around the J-Box covers. Remove J-Box cover plate. Remove appropriate knockout and assemble certified conduit connector for the supply wire used. Connect supply ground wire to fixture ground wire. Connect common supply wire to white fixture wire. Connect 120V or 277V supply wire to the respec-tive 120V or 277V fixture wire. Use certified wire nuts. Reinstall J-Box cover.

WARNING: DO NOT pinch wires between J-Box/ballast cover and J-Box. Consult a Qualified Electrician for all other options that require other wiring configurations.

4. Install reflector after all ceiling installation and finishing work is complete.

Insert sides of heatsink spring into reflector neck clearance slots, then twist heatsink and push down until desired position on the reflector is obtained. Align heatsink spring with appropriate reflector slots. Heatsink will lock into place, but may be readjusted by twisting and sliding the heatsink into another position. Do NOT use the reflector neck clearance slots as a final installation position for the heatsink.

5. Push reflector into the plaster flange until the reflector is flush against the ceiling.

6. Install the proper lamps (by others).7. For housing CAT. NO. D4MR, install a lamp

marked “Suitable for use in open luminaires” unless used in combination with Prescolite CAT. NO. 2MLH.

8. To install the accessory CAT. NO. 2MLH, first have the reflector installed in the housing. Separate the halves of 2MLH by twisting them apart. Remove the lens retainer wire. Place the maximum quantity of two (2) optical accessories and the MR16 lamp into the bottom half of 2MLH. Replace the lens retainer wire over the edge of the MR16 lamp. Combine the halves of 2MLH by twisting them together. Finally, insert the MR16 lamp pins into the Leviton MR16 lampholder. Replace removable parts after servicing.

Wing Nut

NOTE: Brackets are supplied flat. To ensure proper alignment, bend brack-ets in line with marks on flange as shown in Detail A.

DETAIL A

2MLH

J-Box Transformer/Ballast Plate

Bend Brackets in Line with Marks on Flange.

NOTE: Remove (3) Grip Clip Springs before installing a Wallwash Trim.

Heatsink

Plaster Flange

J-Box Cover

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

dna ylppus rewop ot gniriw erofeB .sesag ro sropav elbitsubmoc ot tcejbus saera ni llatsni ton oD .gnipmal reporp dnaduring servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard. Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.WARNING - This product contains chemicals known to the State of California to cause cancer, birth defects and/or otherreproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.

See Label for Lamp Positioning:

Heatsink Spring

Media Holder Bottom

Lens Retainer Ring

Media Holder Top

Page 1 of 2

ww

w.prescolite.com

• Assistance technique gratuite de P

rescolite 1 888 PRS-4TEC

• Heures : 8 h à 17 h H

NE

Mode d'em

ploi

701 Millennium Boulevard • Greenville, SC 29607, États-Unis Services de représentants offerts dans les grandes villes de l'Amérique du Nord.Droit d'auteur 2015, 6/8/15. Tous droits réservés. Imprimé aux États-Unis.

No pièce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93001353

INSTRUCTIONS D'INSTALLATION No CAT. D4

Réflecteur

Support de montage ajustable

MISE EN GARDE : N'ESSAYEZ PAS DE MODIFIER OU DE RECÂBLER LE CIRCUIT ÉLECTRIQUE DU LUMINAIRE INSTALLÉ EN USINE. LA SÉCURITÉ ET LE BON FONCTIONNEMENT DU LUMINAIRE DÉPENDENT DE L'INTÉGRITÉ DU CÂBLAGE.

CONSERVEZ CES INSTRUCTIONS.

1. Pliez les supports comme l’illustre le détail « A ». Installez le luminaire au plafond en vous servant des rails ou de barres de suspension (B6, B24, ou autres non compris) placés dans les supports de montage ajustables. Installez le luminaire au plafond de sorte que le poids de l'appareil soit supporté par le rail de montage, la barre de montage ou par les fils de suspension fixés à la structure du bâtiment.

2. Ajustez le luminaire de manière à mettre au même niveau le bord de la partie inférieure de l'orifice de la bride en plâtre et la ligne de finition du plafond. Assurez-vous également d'aligner l'appareil avec les autres luminaires adjacents. Fixez les supports de montage en serrant les écrous à oreilles de chaque côté du luminaire.

3. Retirez et jetez l'attache à fils autour des boîtes de raccordement. Retirez le couvercle de la boîte de raccordement. Enlevez les alvéoles défonçables appropriées et assemblez le connecteur homologué qui convient au fil d'alimentation utilisé. Raccordez le fil d'alimentation mis à la terre au fil de mise à la terre du luminaire. Raccordez le fil d'alimentation commun au fil blanc du luminaire. Raccordez le fil d'alimentation 120V ou 277V au fil 120V ou 277V respectifs du luminaire. Utilisez des capuchons de connexion certifiés. Remettez en place le couvercle de la boîte de raccordement.

AVERTISSEMENT : Faites attention à NE PAS pincer les fils entre le couvercle de la boîte de raccordement/du ballast et la boîte de raccordement. Consultez un électricien qualifié pour toutes les autres possibilités nécessitant des configurations de câblage différentes.

4. Après avoir terminé tous les travaux d'installation et de finition au plafond, installez le réflecteur. Insérez les côtés du dissipateur thermique comportant des ressorts dans les fentes du collet du réflecteur, puis tournez et poussez sur le réflecteur jusqu'à la position désirée. Alignez les ressorts du dissipateur thermique avec les fentes du réflecteur. Le dissipateur thermique se verrouillera, mais on peut l'ajuster en le tournant et en le glissant dans une autre position. NE PAS utiliser les fentes d'espacement du col du réflecteur comme position d'installation finale du dissipateur thermique.

5. Poussez le réflecteur dans la bride pour plâtre jusqu'à ce qu'il soit à plat contre le plafond.

6. Installez les ampoules appropriées (non comprises).7. Pour le boîtier N° CAT. D4MR, installez une ampoule

de type « Convient aux luminaires ouverts » à moins de l'utiliser avec N° CAT. 2MLH de Prescolite.

8. Pour installer l'accessoire N° CAT. 2MLH, installez d'abord le réflecteur dans le boîtier. Séparez les 2 moitiés du 2MLH en les dévissant complètement. Retirez l'anneau de retenue de la lentille. Installez une quantité maximale de 2 accessoires optiques et l'ampoule MR16 dans la partie inférieure du 2MLH. Replacez l'anneau de retenue sur le contour de l'ampoule MR16. Vissez les deux parties du 2MLH. Finalement, insérez les broches de l'ampoule MR16 dans la douille Leviton MR16. Replacez les pièces amovibles après l'entretien.

Écrou à oreilles

REMARQUE : Les supports fournis sont plats. Pour assurer un alignement adéquat, pliez-les de façon parallèle aux marques de la bride, comme l’illustre le détail « A ».

2MLH

Boîte de raccorde-ment

Plaque du transformateur/Ballast

REMARQUE : Retirez les trois pinces à ressort avant d'installer une garniture lèche-mur

Dissipateur thermique

Rebord pour plâtre

Couvercle de boîte de raccorde-ment

IMPORTANTES INFORMATIONS SUR LA SÉCURITÉ. LISEZ ET RESPECTEZ TOUTES LES CONSIGNES DE SÉCURITÉ. Lisez les informations et suivez les consignes sur l'étiquette relativement aux emplacements mouillés ou humides, à l'installation à proximité de matériaux combustibles, à l'isolation, aux matériaux de construction et aux ampoules appropriées. Ne pas installer dans des endroits où il y a possibilité de vapeurs ou de gaz combustibles. Avant de relier l'appareil à l'alimentation électrique et pendant son entretien ou le remplacement des ampoules, coupez le courant au niveau du fusible ou du disjoncteur. Tous les travaux d'entretien et le remplacement d'ampoules doivent être effectués par un personnel d'entretien qualifié. Le produit doit être mis à la terre afin d'éviter les risques d'électrocution ou autres dangers potentiels. Le produit doit être installé dans des endroits et à des hauteurs, ainsi que par des moyens compatibles avec l'usage prévu et ce, en conformité au Code national de l'électricité et aux codes locaux. L'utilisation d'appareils accessoires non recommandés par le fabricant ou installés contrairement aux instructions peut créer des conditions dangereuses. Ne bloquez pas la lumière émise par le produit, complètement ou partiellement, car cela peut créer des conditions dangereuses. Ne laissez pas des articles tels que des draps, des rideaux ou autres objets semblables entrer en contact avec le produit ou bloquer la lumière émise par celui-ci, car cela peut créer des conditions dangereuses.AVERTISSEMENT : Ce produit contient des produits chimiques, reconnus par l'État de la Californie comme étant des substances pouvant causer le cancer, des anomalies congénitales ou un danger pour la reproduction. Bien se laver les mains après avoir installé, manipulé, nettoyé ou touché ce produit d'une façon quelconque.

Voir l'étiquette pour la mise en place de l'ampoule

Ressort du dissipateur thermique

Support à média supérieur

Anneau de retenue de lentille

Support à média inférieurMedia Holder Bottom

Lens Retainer Ring

Media Holder Top

Pliez les supports en les alignant avec les marques de la bride.

DÉTAIL « A »

Page 2 of 2