INSTALLATION INSTRUCTIONS - AdamsRite
Transcript of INSTALLATION INSTRUCTIONS - AdamsRite
PRODUCT MUST BE INSTALLEDACCORDING TO ALL APPLICABLE
BUILDING AND LIFE SAFETY CODES
[20.32].182
[15.52].611
[3.0]R.120
"A"
"A"
"A"
BEVEL
RADIUS
FLAT
CL
CL
CL
CL
CL
CL
FOR OPTIMUM LOCK PERFORMANCE, THE GAP BETWEEN THE DOOR AND FRAME MUST MEET INDUSTRY STANDARDS OF AN 1/8"
1.010- .000+.015
25.7 0+0.4
"A"
[40.48]1.594
[174.9]6.885
STILE PREPARATION
+.38 -.00
R.156[3.96]TYP.
+.005 -.000
4.635117.7
[1.5].06
.57014.5
5.375136.5
[36.5]1.437
[70.3]2.769
RADIUS WEATHER STRIP
RADIUS
FLAT
AVAILABLE FACEPLATES
Adjustable Mounting Tube Bracketmay be removed for mounting on bridges, tabs, or either methods.
CL
CL
CYLINDERCL
CL
DOORCL
TO JAMB EDGE
Drill and c'sk for#10-32 X 1/2"Flat Head Machine Screws
4581Cam Plug Assy.(included with 4300)
INSTALLATION
CL
4581FRONT VIEW
(Must use a Face Plate for installation)
"A".6215.7
.4210.6
6.81173
5.80147.3
1.58740.3
1.43736.5
2.76970.3
6.38162
.98024.9
.6315.9
1.0025.4
"B"
6.38162.1
CL
BACK OF STILE
2x#10-32
UNC-2B
Flat Face Plate can beadjusted for right or leftbeveled edge doors.Radius Weather Strip isoptional.
HOW BACKSETIS MEASURED
CAM TOLERANCE: ±.005 ( ±.13 )
CYLINDERCL
DIMENSIONSInches
(Millimeters)
Turning Key / Handle / PaddleDOES NOT pull Main Latch Assy.
OPERATION INSTRUCTIONPress Aux Latch to secureMain Latch. Turn key, applyvoltage, or operate Paddle/Handleto unlock Main Latch.As door opens, Main Latchpivots and collapses.
[20.32].182
[15.52].611
[3.0]R.120
Page of1 2
INSTALLATION INSTRUCTIONS
Rev. Appvd: MP ECN:11899 Date: 03/16/12 D
4300 SERIES ELECTRIFIED DEADLATCH
80-0180-421
Adams Rite Manufacturing Co.260 Santa Fe Street,Pomona, CA 91767
Phone: 909-632-2300Fax: 909-632-2369
www.adamsrite.com
PRODUCT MUST BE INSTALLEDACCORDING TO ALL APPLICABLE
BUILDING AND LIFE SAFETY CODES
Black = CommonWhite = N.O. contact (Dry)Red = N.C. contact (Dry)Unused wires must be cut such that no exposed wire will touch any metallic surface
EXAMPLE WIRING DIAGRAM WITH N.O. MONITORING
AccessControlSystem
X
4300MONITOR
Black
White
Red
4300 WIRING DIAGRAMINTERMITTENT / CONTINUOUS DUTY 12 / 24V DC
SOLENOID SPECIFICATION
SOLENOID AVAILABLE VOLTAGES 12V DC CONTINUOUS DUTY, 24V DC CONTINUOUS DUTY.
120V ACLINE
VOLTAGE
4605 / 4606 -24V AC40 VA TRANSFORMER
RED -
46032-AMP
RECTIFIER
RED -BLACK (-)
4300ELECTRIFIED DEADLATCH
WHITE (+)
ORANGE
BLUE
YELLOW
BROWN
12V DC
4300
4300
YELLOW
24V DC
ORANGE
BLUE
BROWN
Bevel Tab
Fig. 4
Yoke
#8-32 x 5/16"Truss Head Screw
Fig. 3
RHR BEVEL POSITION
LHR BEVEL POSITION
Fig. 5
Dim.Depth
Inside Stilewall
Fig. 1
Depth Dim.
3/16"Hex Key
MountingPlate
TubeSpacer
Fig. 2
FLAT FACE PLATENEUTRAL POSITION
Screwdriver
RemoveBevel Tabs
Fig. 6
RADIUS WEATHERSEALFACEPLATES ONLY
WIRES BUNDLE
VOLTAGEADAPTOR CABLE
4300 SERIESELECTRIFIED DEADLATCH
Fig. 7
MONITORING (OPTIONAL)
MONITORED DEADLATCH CONTAINS AN INTERNALLY MOUNTED SWITCH. THIS SWITCH IS ACTIVATED WHEN THE DOOR IS IN CLOSE POSITION. ALL UNUSED LEADS FROM THE MONITOR SWITCH MUST BE INSULATED.
Common contact - BlackNormally Open contact (N.O.) - WhiteNormally Closed contact (N.C.) - RedMaximum switching current - 0.1 Amps @ 125 VAC
- LOOP THE WIRES BUNDLE FROM 4300 ELECTRIFIED 'S SOLENOID UNDER AND AROUND ITS HOUSING AS SHOWN (Fig.7).- EXTEND THE WIRES RUN FROM THE POWER SOURCE AND THROUGH THE STILE PREPARATION.- CONNECT THE WIRE TO THE VOLTAGE ADAPTOR CABLE. - ATTACH VOLTAGE ADAPTOR CABLE TO 4300 WIRES BUNDLE AS SHOWN.
SOLENOID WIRING DIAGRAM
Note: NOT intend to be a Rex switch.
Page of2 2
INSTALLATION INSTRUCTIONS
Rev. Appvd: MP ECN: 11899 Date: 03/16/12D
4300 SERIES ELECTRIFIED DEADLATCH
80-0180-421