Installation instruction IMAX ADJUSTABLE BR8€¦ · Installation instruction IMAX® ADJUSTABLE BR8...
Transcript of Installation instruction IMAX ADJUSTABLE BR8€¦ · Installation instruction IMAX® ADJUSTABLE BR8...
1
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
Installation instruction IMAX® ADJUSTABLE BR8
Application Ceiling recessed
Finishing section to be used with DELTA LIGHT® rough-in housing
For indoor use only
Ceiling ThicknessFor 5/8" ceiling standard up to 7/8”
Light source1x powerled white 10,4W Bridgelux
ConnectorHousing and trim connection through snap-in connector
Power SupplyCurrent controlled class 2 power supply required. (supplied with housing)
max 500mA, typical forward voltage 20,7V. Do not interconnect in parallel!
Product descriptionSurface treated aluminum construction
Pre-installed springs for easy installation
Adjustable
Suitable for dry and damp location
Protected against solid objects greater than 12mm IP20
Weight: 0,9lbs 0,4kg
DimensionsHeight: 132mm = 5”-3/16
Ceiling Cut out: Ø98mm = 3”-27/32
Required accessoriesiMAX® COVER ROUND 400 00 11
iMAX® COVER ROUND IP 400 00 21
iMAX® COVER SQUARE 400 00 55
iMAX® COVER ROUND FLUSH 400 00 19(Can only be used with MOUTING KIT FLUSH equiped housings with article number 6 202 7xx 70 xx)
IMAX® ADJUSTABLE BR8 92729
6 402 01 811 922
IMAX® ADJUSTABLE BR8 92743
6 402 01 811 923
IMAX® ADJUSTABLE BR8 93029
6 402 01 811 932
IMAX® ADJUSTABLE BR8 93043
6 402 01 811 933
IMAX® ADJUSTABLE BR8 93529
6 402 01 811 952
IMAX® ADJUSTABLE BR8 93543
6 402 01 811 953
132mm
5”-3/16
355°
0-30°
ICAT
OR
OROR
Conforms to ANSI/UL Std. 1598
Cert. to CAN/CSA Std. 22.2 No. 250.0
Last Update ALLU 04/02/2019
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
7 - IC AT Housing S
6
6
6
6
6
6
6
6
6
6
6
6
202
202
202
202
202
202
202
202
202
202
202
202
46 - PK170
46 - PK170
46 - PK170
46 - PK170
69 - EMP R98
69 - EMP R98
69 - EMP R98
69 - EMP R98
70 - MTK FLUSH
70 - MTK FLUSH
70 - MTK FLUSH
70 - MTK FLUSH
3 - 120-277V
1 - 120V
1 - 120V
3 - 120-277V
3 - 120-277V
1 - 120V
1 - 120V
3 - 120-277V
3 - 120-277V
1 - 120V
1 - 120V
3 - 120-277V
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - 120V2 - 277V3 - 120-277V
Range Installation type
Lamp Source Opening
Voltage Mounting Option
Plasterframe for NIC and/or NON airtight applications
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
01 - IC AT Housing S
6
6
6
6
6
6
6
6
6
6
6
6
202
202
202
202
202
202
202
202
202
202
202
202
43 - 500mA-DC 12W ED1 UNV
49 - 500mA-DC 12W 120V
62 - 500mA-DC 12W ED8 120V
72 - 500mA-DC 19W ED10 UNV
43 - 500mA-DC 12W ED1 UNV
49 - 500mA-DC 12W 120V
62 - 500mA-DC 12W ED8 120V
72 - 500mA-DC 19W ED10 UNV
43 - 500mA-DC 12W ED1 UNV
49 - 500mA-DC 12W 120V
62 - 500mA-DC 12W ED8 120V
72 - 500mA-DC 19W ED10 UNV
43 - 500mA-DC 12W ED1 UNV
49 - 500mA-DC 12W 120V
62 - 500mA-DC 12W ED8 120V
72 - 500mA-DC 19W ED10 UNV
43 - 500mA-DC 12W ED1 UNV
49 - 500mA-DC 12W 120V
62 - 500mA-DC 12W ED8 120V
72 - 500mA-DC 19W ED10 UNV
43 - 500mA-DC 12W ED1 UNV
49 - 500mA-DC 12W 120V
62 - 500mA-DC 12W ED8 120V
72 - 500mA-DC 19W ED10 UNV
46 - PK170
46 - PK170
46 - PK170
46 - PK170
69 - EMP R98
69 - EMP R98
69 - EMP R98
69 - EMP R98
70 - MTK FLUSH
70 - MTK FLUSH
70 - MTK FLUSH
70 - MTK FLUSH
1 - 120V / 2 - 277V
1 - 120V
1 - 120V
1 - 120V / 2 - 277V
1 - 120V / 2 - 277V
1 - 120V
1 - 120V
1 - 120V / 2 - 277V
1 - 120V / 2 - 277V
1 - 120V
1 - 120V
1 - 120V / 2 - 277V
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard
1 - 120V2 - 277V3 - 120-277V
Range Installation type
Lamp Source OpeningVoltage Mounting Option
0 - No bar hangers
1 - Bar hangers standard0 - No bar hangers1 - Bar hangers standard
Required options for non-class 2 power limited circuitsHousing for IC and/or airtight applications
NIC
4
Installation instruction IMAX® ADJUSTABLE BR8
2
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
A
B
A
B
SAVE!
B
A
Accessories
1 MOUNTING TEMPLATE
INSTALLATION LUMINAIRE
1x
1x
1xDIN911/1,5
Part no. 6 300 92 91 04 supplied
with the rough-in housing or plasterframe
32
RED = 3
BLACK = 1
1
1
23
RED = 3
BLACK = 12
3 0°-30°
FIX 0-30°
OPENING
OF HOUSING
ICAT
HOUSING
NIC
PLASTERFRAME
Not Supplied
Rough-in Housing / Plasterframe
Required
Installation instruction IMAX® ADJUSTABLE BR8
3
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
INSTALLATION LUMINAIRE
355°
5
1x
i
7FOR MAINTENANCE
6 PLACING COVER