INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or...
Transcript of INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or...
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
PD-87741877-LED Pendant
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
G0
ScrewQty:1 Extra
1/8"-40×1/2 Chrome Plating
Optional Metal CapQty:1 Extra
Chrome Plating
Wire ConnectorQty: 3pcs+1 Extra
P3
Junction Box ScrewQty: 2pcs+1 Extra
8#-32×13/16Nickel Plating
Mounting ScrewQty:1 Extra
5/32"-32×1/2Chrome Plating
A D EB C
PD-27802278-LED Pendant
Wire Connector
Qty: 3pcs+1 Extra
P3
Junction Box Screw
Qty: 2pcs+1 Extra
8#-32×13/16
Nickel Plating
Mounting Screw
Qty:1 Extra
5/32"-32×1/2
Chrome Plating
A B C
WS-35819/ WS-35825/ WS-35837/ WS-35849/WS-35861
358 – LED Wall Sconce
Wire ConnectorQty: 3pcs+1 Extra
Mounting ScrewQty:2pcs+1 Extra
7EAC112201
A
Plastic Anchor Qty: 2pcs+1 Extra
Wood Screw Qty: 2pcs+1 Extra
Ф4X224MPF0308S3W5(WT)1/8"-40X3/8
Nickel Plating/White
C EB
Silicon GasketQty:2pcs
FD
Decorative PlateQty:1pc
4MBA121244BA(AL)4MBA121244W10(WT)
7TGD272501CL1/8”-40x17MPF0308S1(AL) 7TDD082401 7MPF2204J2
Assembly ScrewQty:2pcs+1 Extra
G
Nickel Plating
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for
installation.
MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of
the mounting back plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in
Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.
COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).
4 1/8”
15”11 3/4”
1 3/8”
1 3/4”
WS-75818MOUNTING BACK PLATE
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
FIG.1 Junction Box Screw
Junction Box
Wire Connector
Driver
Plastic Anchor
Mounting Plate
Wood Screw
Mounting Screw
B
A
D
C
E
PD-87741877-LED Pendant
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
G0
Plate
Ground Wire Screw
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
Plastic
D
C
B
A
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
3. Remove the mounting screw (C) from the fixture.
5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
6. Secure the canopy to the mounting plate using the mounting screw (C).
4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
PD-27802278-LED Pendant
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
10 5
/16"
1 3/4"
1 3/
8"
3. Remove the mounting screw (C) from the canopy.
6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
Ground Wire Screw
Plate
C
B
A
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
7. Hook the safety cord to the mounting plate.
8. Secure the canopy to the mounting plate using the mounting screw (C).
WS-35819/ WS-35825/ WS-35837/ WS-35849/WS-35861
358 – LED Wall Sconce
Fig.1
Fig.2
A Wire Connector
Plastic AnchorF
Mounting ScrewBWood ScrewG
Acrylic Diffuser PC strip
Decorative Plate
Junction Box
Assembly Screw
Silicon Gasket
Ground Wire
D
End Cap
E
C
Wire Connector
Plastic Anchor
Mounting ScrewWood Screw
Acrylic Diffuser PC strip
Wall Hole
Ground Wire
A
B
End Cap
F
G
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for
installation.
MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of
the mounting back plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in
Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.
COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).
4 1/8”
15”11 3/4”
1 3/8”
1 3/4”
WS-75818MOUNTING BACK PLATE
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
FIG.1 Junction Box Screw
Junction Box
Wire Connector
Driver
Plastic Anchor
Mounting Plate
Wood Screw
Mounting Screw
B
A
D
C
E
PD-87741877-LED Pendant
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
G0
Plate
Ground Wire Screw
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
Plastic
D
C
B
A
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
3. Remove the mounting screw (C) from the fixture.
5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
6. Secure the canopy to the mounting plate using the mounting screw (C).
4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
PD-27802278-LED Pendant
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
10 5
/16"
1 3/4"
1 3/
8"
3. Remove the mounting screw (C) from the canopy.
6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
Ground Wire Screw
Plate
C
B
A
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
7. Hook the safety cord to the mounting plate.
8. Secure the canopy to the mounting plate using the mounting screw (C).
WS-35819/ WS-35825/ WS-35837/ WS-35849/WS-35861
358 – LED Wall Sconce
Junction Box / Wall Hole
WS-35819: 18 1/4"WS-35825: 24 3/16"WS-35837: 36 1/4"WS-35849: 48 1/4"WS-35861: 59 13/16"
Installation Location
4. Secure the decorative plate (E) to the fixture with assembly screw (C), then replace the existing silicon gasket with the supplied silicon gasket (D).
5. Remove the mounting screw (B) and the end cap from the fixture.
3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F). Line up the center line of the drill holes with respect to the center line of the junction box to allow the decorative plate (E) properly cover up the junction box opening on the wall.
8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser.
MOUNT ON THE JUNCTION BOX (Fig. 1)
MOUNT WITHOUT JUNCTION BOX (Fig. 2)
OR
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
PREPARATION
6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the junction box.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G), make sure to align the decorative plate to adequately cover the junction box wall opening.
4. Remove the mounting screw (B) and the end cap from the fixture.5. Drill a small access hole in the wall behind the fixture and pull the house wires through the wall.
3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F).
8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser.
6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the wall hole.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.3 Wiring
3
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
PD-87741877-LED Pendant
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
G0
ScrewQty:1 Extra
1/8"-40×1/2 Chrome Plating
Optional Metal CapQty:1 Extra
Chrome Plating
Wire ConnectorQty: 3pcs+1 Extra
P3
Junction Box ScrewQty: 2pcs+1 Extra
8#-32×13/16Nickel Plating
Mounting ScrewQty:1 Extra
5/32"-32×1/2Chrome Plating
A D EB C
PD-27802278-LED Pendant
Wire Connector
Qty: 3pcs+1 Extra
P3
Junction Box Screw
Qty: 2pcs+1 Extra
8#-32×13/16
Nickel Plating
Mounting Screw
Qty:1 Extra
5/32"-32×1/2
Chrome Plating
A B C
WS-35873/WS-35897358 – LED Wall Sconce
Wire ConnectorQty: 3pcs+1 Extra
Mounting ScrewQty:2pcs+1 Extra
7EAC112201
A
Plastic Anchor Qty: 6pcs+1 Extra
Wood Screw Qty: 2pcs+1 Extra
Ф4X224MPF0308S3W5(WT)1/8"-40X3/8
Nickel Plating/White
C EB
Silicon GasketQty:2pcs
FD
Decorative PlateQty:1pc
4MBA121244BA(AL)4MBA121244W10(WT)
7TGD272501CL1/8”-40x17MPF0308S1(AL) 7TDD082401 7MPF2204J2
Assembly ScrewQty:2pcs+1 Extra
G
Nickel Plating
Tapping ScrewQty: 4pcs+1 Extra
7MPF033502
H
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for
installation.
MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of
the mounting back plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in
Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.
COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).
4 1/8”
15”11 3/4”
1 3/8”
1 3/4”
WS-75818MOUNTING BACK PLATE
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
FIG.1 Junction Box Screw
Junction Box
Wire Connector
Driver
Plastic Anchor
Mounting Plate
Wood Screw
Mounting Screw
B
A
D
C
E
PD-87741877-LED Pendant
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
G0
Plate
Ground Wire Screw
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
Plastic
D
C
B
A
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
3. Remove the mounting screw (C) from the fixture.
5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
6. Secure the canopy to the mounting plate using the mounting screw (C).
4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
PD-27802278-LED Pendant
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
10 5
/16"
1 3/4"
1 3/
8"
3. Remove the mounting screw (C) from the canopy.
6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
Ground Wire Screw
Plate
C
B
A
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
7. Hook the safety cord to the mounting plate.
8. Secure the canopy to the mounting plate using the mounting screw (C).
WS-35873/WS-35897358 – LED Wall Sconce
Fig.1
Fig.2
Installation Location
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.3 Wiring
A Wire ConnectorPlastic AnchorF
Wood ScrewG
Acrylic DiffuserPC strip
Mounting ScrewB
End Cap Decorative Plate
Assembly Screw
Silicon Gasket
Ground Wire
Junction Box
D
E
C
Wire Connector
Plastic Anchor
Wood Screw
Acrylic Diffuser PC strip
Mounting Screw
End Cap
Tapping Screw
B
A
Ground Wire
F
GH
Junction Box / Wall Hole
****
WS-35873: 72 1/4"WS-35897: 96 5/16"
WS-35873: 56 1/8"WS-35897: 80 3/16"
(If necessary)
13/1
6"
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for
installation.
MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of
the mounting back plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in
Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.
COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).
4 1/8”
15”11 3/4”
1 3/8”
1 3/4”
WS-75818MOUNTING BACK PLATE
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
FIG.1 Junction Box Screw
Junction Box
Wire Connector
Driver
Plastic Anchor
Mounting Plate
Wood Screw
Mounting Screw
B
A
D
C
E
PD-87741877-LED Pendant
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818
HARDWARE
A B C D E
Wire ConnectorQty: 3pcs+1 Extra7EAC112201
Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating
Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22
Plastic Anchor Qty: 2pcs+1 Extra7TDD082401
Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
G0
Plate
Ground Wire Screw
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
Plastic
D
C
B
A
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
3. Remove the mounting screw (C) from the fixture.
5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
6. Secure the canopy to the mounting plate using the mounting screw (C).
4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
PD-27802278-LED Pendant
2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
waclighting.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114
PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),
fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.
7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Di�user
Mounting Plate
Junction Box
Glass(RPL-GLA-13114)
Shade(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø7"
Back Plate Dimensions
GND
Ø8 3/4"
Ø2 3/4"
Ø3 1/2"
FM-16818168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture Shade
PC Diffuser
Wire Connector
Plastic Anchor
Wood Screw
Junction Box Screw
Mounting Screw Glass(RPL-GLA-13114)
Shade(RPL-SHA-16818)
Diffuser(RPL-DIF-13114)
G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.comPhone (800) 526.2588Fax (800) 526.2585
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
HARDWARE
WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.
CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.
AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636
Wire ConnectorQty: 3 pcs
7EAC112201
MountingRing
Qty: 1 pc7MBC101501
Transformer
Qty: 1 pc5EN-2460-R2
JunctionBox ScrewQty: 2 pcs+ 1 Extra
7MPF0825C18-32x1 SS
ConversionPlate
Qty: 1 pc4MBA151110BA
MountingScrew
Qty: 2 pcs+ 1 Extra
7MPF0415C28-32x9/16 SS
SetScrew
Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating
MountingAnchor
Qty: 2 pcs7TDD082401
TappingScrew
Qty: 2 pcs7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
10 5
/16"
1 3/4"
1 3/
8"
3. Remove the mounting screw (C) from the canopy.
6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.
4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 2)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
MOUNTING THE FIXTURE(Fig.1)
Fixture WiresBlack or Smooth
Fixture WiresWhite or Ribbed
Fixture WiresBare wire(Ground)
House WiresBlack(Hot)
House WiresWhite (Neutral)
House WiresGreen or Bare Copper(Ground)
Fig.2 Wiring
Ground Wire Screw
Plate
C
B
A
3 3/8" L X 2 3/8" W X 1 1/4" H Driver
7. Hook the safety cord to the mounting plate.
8. Secure the canopy to the mounting plate using the mounting screw (C).
WS-35873/WS-35897358 – LED Wall Sconce
4. Secure the decorative plate (E) to the fixture with assembly screw (C), then replace the existing silicon gasket with the supplied silicon gasket (D)
5. Remove the mounting screw (B) and the end cap from the fixture.
3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F).Line up the center line of the drill holes with respect to the center line of the junction box to allow the decorative plate (E) properly cover up the junction box opening on the wall.
8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser.
MOUNT ON THE JUNCTION BOX (Fig. 1)
MOUNT WITHOUT JUNCTION BOX (Fig. 2)
OR
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
PREPARATION
6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the junction box.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G), make sure to align the decorative plate to adequately cover the junction box wall opening.
4. Remove the mounting screw (B) and the end cap from the fixture.5. Drill a small access hole in the wall behind the fixture and pull the house wires through the wall.
3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F).
8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser. * If the fixture and wall have a large gap, tapping screw (H) can be used when installing the fixture.
6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the wall hole.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G).
3