Installation guide for CX3 RG 7/11 compression connectors

17
Corning Cabelcon 1

description

Installation guide for CX3 RG 7/11 compression connectors. To begin with – we need some tools…. Please read the instructions before using the tools !. Mounting tools. Cable cutter. Compression tool. Cabelcon RG11 Rotary Stripper. Let’s start to work …. - PowerPoint PPT Presentation

Transcript of Installation guide for CX3 RG 7/11 compression connectors

Page 1: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

1

Page 2: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

2

To begin with – we need some tools…

Cablecutter

Cabelcon RG11 Rotary Stripper

Mounting tools

Compression tool

Please read the instructions

before using the tools!

Page 3: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

3

Let’s start to work…

First step is to cut your cable using a

proper cable cutter.

Page 4: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

4

Strip your cable…

Insert the cable into the cable stripper as

shown…

Attention: Please make sure to adjust the tool blades for your cable dimensions before using it for the first time! Please read instructions supplied with the tool.

Screws for adjustment of blades

Hex tool for adjustment

Page 5: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

5

Strip your cable…

Turn the stripper clockwise 4-5 times…

Page 6: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

6

Strip your cable…

- Press the tool jaws together around the

cable and pull to remove the scraps…

Page 7: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

7

Strip your cable…

Optional:

You can check the stripping dimensions against the guide printed on the connectors

6,5 + 6,5 mm (¼” + ¼”)

Page 8: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

8

Prepare your cable…

Fold exposed braid over the jacket.

Leave the inner foil attached to the dielectric

and make sure that the foil is undamaged and smooth.

For ”Quad shield”, ”Tri shield”

and ”Super shield” cables: Remove the outer braid and foil only. Fold back the inner

braid.

Page 9: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

9

Push the connector over the foil and allow the support mandrel to slide between the foil and braid…

Mount the connector…

Page 10: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

10

Press and turn until the pin is pushed forward and visible as shown.

Mount the connector…

Mounting tools can be used to ensure a better grip on both connector and the cable…

Page 11: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

11

Compress the connector…1) Insert your connector/cable into the tool with the tool handle in open position…

2) Apply a downward pressure on the cable to allow the split jaws to secure the cable…

Click!

Page 12: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

12

Compress the connector…

- and close the tool handle completely insuring the connector sleeve is fully compressed.

Page 13: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

13

Open the tool - press the outside split-jaw tabs and pull out the connector assembly…

Take out the connector…

CX3 RG7/11 Compression completed!

Page 14: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

14

The inner conductor grip is very precise due to the movable pin system.You cannot miss it.

Use your scroll mouse or the arrow keys to go forward and back…

Insert cable

This how the movable pin technology works…

Page 15: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

15

Insert cable

Use your scroll mouse or the arrow keys to go forward and back…

This how the movable pin technology works…

The inner conductor moves forward to indicate proper installation when the cable is pushed forward in place.

Page 16: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

16

Use your scroll mouse or the arrow keys to go forward and back…

Compression locks the cable and terminates the installation.

This how the movable pin technology works…

Page 17: Installation guide for CX3 RG 7/11 compression connectors

CorningCabelcon

17CorningCabelcon

17

Thank you for watching this instruction

January 2008