Installation Guide - ALC Lighting Controls

62
320 300 358 250 M8 No.14 Fixing Size Maximum 61 45/46 66 35 L E N + - SCN Switched Live Earth Neutral Maintained Live +V 0V In2/Off/LS In1/On/PD Mains Comms 1/2 Turn Fixing N L1 N L1 For Switches requiring 2 wires connect between 0V & Off For Switches requiring 3 wires connect between 0V,On & Off Alternative: Wieland 34.362.0211.1 Order Code: AX-OPGST18 Output Connector Wiring Alternative: RS 189-6032 Order Code: AX-IPBL4 Input Connector Wiring Dimming 0V Dimming Line Spectrum System Installation Guide Dual Fix Pluggable Lighting Control Module P1 AXPL98ATDH Document AID1001 Iss 3

Transcript of Installation Guide - ALC Lighting Controls

Page 1: Installation Guide - ALC Lighting Controls

320300

358

250

M8

No.14

Fixing Size Maximum

61

45/46

66

35

L

E

N

+-

SC

N

Switched Live

Earth

Neutral

Maintained Live

+V

0V

In2/Off/LS

In1/On/PD

Mains Comms

1/2 Turn Fixing

NL

1N

L1

For Switches requiring 2 wires connect between 0V & OffFor Switches requiring 3 wires connect between 0V,On & Off

Alternative: Wieland 34.362.0211.1

Order Code: AX-OPGST18

Output Connector Wiring

Alternative: RS 189-6032

Order Code: AX-IPBL4

Input Connector Wiring

Dimming 0V

Dimming Line

Spectrum System

Installation GuideDual Fix Pluggable Lighting Control Module

P1 AXPL98ATDH Document AID1001 Iss 3

Page 2: Installation Guide - ALC Lighting Controls

1/2 Turn Fixing

LCM Installation

Pluggable Sensors

Spectrum System

Installation GuideDual Fix Pluggable Lighting Control Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXPL98ATDH Document AID1001 Iss 3

Page 3: Installation Guide - ALC Lighting Controls

Switched LiveEarth

NeutralMaintained Live

NL

1N

L1

248

288

179

270

Fixing Size Maximum

No.14

M6

Input from Modular

Wiring InfrastructureWiring Infrastructure

Output to Modular

For Switches requiring 3 wires connect between 0V,On & OffFor Switches requiring 2 wires connect between 0V & Off

In1/On/PD

In2/Off/LS

0V

+V

Pluggable

Sensors

Alternative: Wieland 34.362.0211.1

Output Connector WiringOrder Code: AX-OPGST18

Input Connector WiringOrder Code: AX-IPBL4Alternative: RS 189-6032

Dimming 0V

Dimming Line

Spectrum System

Installation GuideSingle Fix Pluggable Lighting Control Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXPL98ATDM Document AID1002 Iss 3

Page 4: Installation Guide - ALC Lighting Controls
Page 5: Installation Guide - ALC Lighting Controls

Preferred Cabling Positions for Mains, Input and Communications Wiring

Mechanical Fixing

OUTPUT 1

OUTPUT 3

OUTPUT 4

OUTPUT 2

320

380

335300

Fixing Size Maximum

No.14

M8

61

32

62

30

Communications

Emergency Test

Outputs

OverrideInputsInputs

Override

Mains

and Looping

Input/OutputInput/Output

and Looping

Mains

Bus

LIVENEUTRALEARTH

SPARE

B A

Spectrum System

Installation GuideHard Wired Lighting Control Module

P1 AXHW48ATDH Document AID1003 Iss 5

Page 6: Installation Guide - ALC Lighting Controls

Live InLive In

Dimming 0V (See Note)

Dimming Line

Output Connector Wiring Input Connector Wiring

Wiring

Live Out 4

Live Out 3

Live Out 2

Live Out 1

Live Feeds

Output Configurations

Example allows for 4 separate Live feeds giving amaximum load per Output of 8 Amps

(Note: Single Phase Only)

maximum load between all four Outputs of 16 AmpsExample allows for a single Live feed giving a

(Note: Maximum Load on any 1 output is 8 Amps)

Note:

The dimming 0V is internally connected between each output connector.

For Switches requiring 3 wires connect between 0V,On & OffFor Switches requiring 2 wires connect between 0V & Off

In1/On/PD

In2/Off/LS

0V

+V

Fused Live Out (Un-switched)

LIVE

Four additional Inputs are available usingPlug In RJ12 Connectors/Leads.

when replacing the enclosure lid.Care should be taken not to damage the leads

Fused Live Out (Switched)

RELAY CONTACT

FUSE

FUSE

RELAY CONTACT

RELAY CONTACT

FUSE

FUSE

RELAY CONTACT

RELAY CONTACT

RELAY CONTACT

RELAY CONTACT

FUSE

FUSE

FUSE

Live Out 4

Live Out 3

Live Out 2

Live In 4

Live In 3

Live In 2

RELAY CONTACT

FUSE

LIVE

Live In

Facility NOT used

Live In 1

Live Out 1

Live Out

Loop Terminal

Live In

Live Out

Spectrum System

Installation GuideHard Wired Lighting Control Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXHW48ATDH Document AID1003 Iss 5

Page 7: Installation Guide - ALC Lighting Controls

Spectrum System

Installation GuideDin Rail Lighting Control Module

P1 AXDN22ATDH Document AID1004 Iss 4

Page 8: Installation Guide - ALC Lighting Controls

Spectrum System

Installation GuideDin Rail Lighting Control Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXDN22ATDH Document AID1004 Iss 4

Page 9: Installation Guide - ALC Lighting Controls

White Tabs

Black Tab

Mechanical Fixing

100

114

160

90

Din Rail Fixing

Panel Mounting

Adaptable Box

Maximum M3.5/No.6

Fixing Size (3 Per LCM)

310

350

200

20

140

Maximum M4/No.10

Fixing Size (4 Per Box)

30

85

SENSORC - +

0V 12

SENSOR8 7

STATUS LED

COMMS LED

SENSOR

+V2 21 1

6SENSOR SENSOR

5

POWER LED

0V+V 0V 12

4SENSOR

3

12 2 21 1

SENSORSENSOR2 1

SENSORC - +

0V 12

SENSOR8 7

STATUS LED

COMMS LED

SENSOR

+V2 21 1

6SENSOR SENSOR

5

POWER LED

0V+V 0V 12

4SENSOR

3

12 2 21 1

SENSORSENSOR2 1

Spectrum System

Installation GuideInput Module

P1 AXDN08SH Document AID1005 Iss 4

Page 10: Installation Guide - ALC Lighting Controls

Wiring

For Switches requiring 3 wires connect between 0V,On & Off

For Switches requiring 2 wires connect between 0V & Off

1/On/PD2/Off/LS+V 0V

Inputs

Wiring Order

Pluggable Sensors

Note:

Wireable Inputs and Sensor Inputs are connected internally e.g. Wireable Input 1 is connected to Sensor Input 1. This means that only a combination up to 8 different numbered Inputs can be used either Wireable or Sensor.

An exception to this would be if two Input devices were required to control the same output e.g. two Presence Detectors in one room.

Spectrum System

Installation GuideInput Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXDN08SH Document AID1005 Iss 4

Page 11: Installation Guide - ALC Lighting Controls

Mechanical Fixing

Fixing Size (4 Per Controller)

280

255

303

240

20

55

50

24

48

16

Typ.

Typ.

IEC Mains Output Socketfor Service use only

Maximum Size M8/No.14

CANCEL

4

3

2

STATUS

1

ENTER

DOWN

UP

Spectrum System

Installation GuideArea Control Unit

P1 A1AC31SH Document AID1006 Iss 2

Page 12: Installation Guide - ALC Lighting Controls

Spine/Field Bus Connector Wiring

Wiring

Bus +

Bus -

Screen

Live

Neutral

Earth

Mains Wiring

Common

On Side

Off Side

Override Switch Connector Wiring

When using an Ethernet SpineEnsure that the cable is tied

and that it is protected withto the Printed Circuit Board

it passes through the housinga suitable grommet/gland where

Ethernet SpineConnector

Spectrum System

Installation GuideArea Control Unit

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 A1AC31SH Document AID1006 Iss 2

Page 13: Installation Guide - ALC Lighting Controls

P1 AXDN12DH Document AID1008 Iss 3

Spectrum System

Installation GuideDali Din Rail Lighting Control Module

Page 14: Installation Guide - ALC Lighting Controls

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXDN12DH Document AID1008 Iss 3

Spectrum System

Installation GuideDali Din Rail Lighting Control Module

Page 15: Installation Guide - ALC Lighting Controls

Mechanical Fixing

Mechanical Details

4931 4

1.0 mm Material

40/42 mm 45 mm

2 to 25 mmMaterial

Diameter Mounting Hole Diameter Mounting Hole

Highest Point nearest toExternal Bright Light Source

Wiring

Wiring shown connected to a typical Dali LCM however connection could be

to any point on the Dali Bus

Spectrum System

Installation GuideDali Sensor

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXDS01SPL Document AID1049 Iss 1

Page 16: Installation Guide - ALC Lighting Controls
Page 17: Installation Guide - ALC Lighting Controls

Wiring

Mechanical Fixing

86

86

35mm Deep Single Wall Box

Secure Switch Plate through Switch Assemblyto back box using 2 off M3.5 Screws(Supplied with Plate)

View On Rear of Switch Assembly

4

O

2

3

1

Wiring shown connected to a typical Dali LCM however connection could be

to any point on the Dali Bus

UP TO COMMS LED5A HBC PROTECTING

OUTIN

EM MAINS INPUT

EMERGENCY OUTPUT

L L N N

16 BALLASTS

MAINSON + +- +-

DALI

2

INPUT 2

STATUS LED

- +C

BUS

- 1+V 2

INPUT 1

+V0V 1 0V

FUSE

RATINGS MAXIMUM

EMERGENCY 5A LC

MA

DD

RE

SS

230V~ 50Hz 5A T45

COOPER CONTROLS LTD

POWER LED

AXDN12DH

MOD LEVEL 6

280703/12345

Note: Box must be Earthed

Connection to Back Box Earth Terminal

EDADA

Spectrum System

Installation Guide5 Button Dali Scene Setting Switch

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrols.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AX-DSP5B Document AID1057 Iss 1

Page 18: Installation Guide - ALC Lighting Controls
Page 19: Installation Guide - ALC Lighting Controls

Wiring

Mechanical Fixing

86

86

35mm Deep Single Wall Box

Secure Switch Plate through Switch Assemblyto back box using 2 off M3.5 Screws(Supplied with Plate)

View On Rear of Switch Assembly

DA

4

O

2

3

1

Wiring shown connected to a typical Dali LCM however connection could be

to any point on the Dali Bus

UP TO COMMS LED5A HBC PROTECTING

OUTIN

EM MAINS INPUT

EMERGENCY OUTPUT

L L N N

16 BALLASTS

MAINSON + +- +-

DALI

2

INPUT 2

STATUS LED

- +C

BUS

- 1+V 2

INPUT 1

+V0V 1 0V

FUSE

RATINGS MAXIMUM

EMERGENCY 5A LC

MA

DD

RE

SS

230V~ 50Hz 5A T45

COOPER CONTROLS LTD

POWER LED

AXDN12DH

MOD LEVEL 6

280703/12345

Note: Box must be Earthed

DAE

Connection to Back Box Earth Terminal

Spectrum System

Installation Guide7 Button Dali Scene Setting Switch

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrols.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AX-DSP7B Document AID1058 Iss 1

Page 20: Installation Guide - ALC Lighting Controls
Page 21: Installation Guide - ALC Lighting Controls

4931 4

1.0 mm Material

40/42 mm

45mm

2 to 25.0 mm Material

Diameter Mounting Hole

Diameter Mounting Hole

Mechanical Fixing

Mechanical Details

Highest Point nearest toExternal Bright Light Source

Spectrum System

Installation GuideCombined Sensor

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXCS01SRJ Document AID1009 Iss 2

Page 22: Installation Guide - ALC Lighting Controls
Page 23: Installation Guide - ALC Lighting Controls

Wiring & Termination

Mechanical Fixing

100mm 100mm

6mm Maximum

Luminaire Chassis8.5mm Diameter Fixing Hole

1mm Minimum

Lamp/Tube

Un-usable Area's

Lighting Control Module (LCM)

Maximum Length 30 Metres

Wire to 0V and Input 2 Terminals

LCM Input Plug

Spectrum System

Installation GuideEmergency Test Light Sensor - Panel Mounted

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXLS00SH Document AID1010 Iss 1

Page 24: Installation Guide - ALC Lighting Controls

Wiring & Termination

Mechanical Fixing

100mm 100mm

6mm Maximum

1mm Minimum

Lamp/Tube

Un-usable Area's

Lighting Control Module (LCM)

Maximum Length 30 Metres

Wire to 0V and Input 2 Terminals LCM Input Plug

T8 Spring Clip

T8 Tube

Light Sensor

Collared Spacer

(Note Orientation)

T5 Spring Clip

T5 Tube

Light Sensor

(Note Orientation)

Collared Spacer

Spectrum System

Installation GuideEmergency Test Light Sensor - Tube Mounted

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXLS58SH Document AID1011 Iss 2

Page 25: Installation Guide - ALC Lighting Controls

Wiring

Locking Tab Uppermost

Wire ColourConnect to InputTerminal Marked

White

Red

Yellow

Blue

IN1/ON/PD

IN2/OFF/LS

0V

+V

White

Red

Blue

Yellow

Spectrum System

Installation GuideSensor Cable

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXCA05RJH Document AID1013 Iss 3

Page 26: Installation Guide - ALC Lighting Controls
Page 27: Installation Guide - ALC Lighting Controls

Wiring & Termination

LCM

To Current Sensor

LCM Input Terminal Block.

Ballast/Inverter/Battery

Tube

Blue (+V)Yellow (0V)

White (In1)Red (In2 or ET)

Maximum Length 30M

Outside of Luminaire

From any potentially

Allow Maximum Spacing

Secure to a suitable interior surfaceusing a double sided self adhesive pador cable tie (Not Supplied)

CurrentSensor

on the inside of the Luminaire.Ensure Minimum amount of Interface Cable

Sensor Cable AXCA05RJH

Hot Parts

the Lamp through the coil.Pass Wires from one end of

Ensure Maximum

Distance betweenCurrent Sensor &Other ElectronicParts of Luminaire

Sensor Cable AXCA05RJ

LCM Sensor Input Socket

(Types may vary)

Terminate to Detail shownOn individual LCM Wiring label.

LCM NOTE:

The White wire (IN1) is not

be cut back to the end of therequired for operation so may

cable sleeve if no Park terminal

Pluggable Interface Wired Interface

[See Note]

Spectrum System

Installation GuideLamp Current Sensor

P1 AX-ETCS1 Document AID1016 Iss 2

Page 28: Installation Guide - ALC Lighting Controls

ON

1 2

1 2

ON

1 2

ON

1 2

ON

Low Sensitivity

Medium Low Sensitivity

Medium High Sensitivity

High Sensitivity

Sensitivity Set Up

The sensitivity of the lamp current sensor can be set to four different levels by setting the DIL switch accessed on the side of the unit, setting as below,

Note: The setting is dependant upon the type of fitting it is connected to, the position of the sensor coil and the DIL switch setting should be set as advised by ALC Lightng Controls.

Spectrum System

Installation GuideLamp Current Sensor

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AX-ETCS1 Document AID1016 Iss 2

Page 29: Installation Guide - ALC Lighting Controls

Wiring & Termination

Mechanical Fixing

Remove the transparent Lid and mount the Sensor using the 4 corner fixing holes.

Lighting Control Module (LCM)

Maximum Length 30 Metres

LCM Input Plug

Terminal MarkingLCM

0V 0V

+V

O/P IN2/OFF/LS

+V

Light SensorTerminal Marking

Replace Transparent Lid after Fixing & Wiring

Cable Type: Any 3 Core Mains Rated Flex.

VIEW WITH LID REMOVED

50

79 94

65

57

32.5

32 30

21

21

6 Knockouts M16/M20

Spectrum System

Installation GuideExternal Light Sensor

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AX-ELS1 Document AID1020 Iss 2

Page 30: Installation Guide - ALC Lighting Controls
Page 31: Installation Guide - ALC Lighting Controls

300

250

160 110

M6/No.12 4 Positions

Fixing Size Maximum

50

50

25

Input Mains Wiring

Mechanical Fixing

Knock Out 20mm

3 Positions

Switched LiveUn-switched Live

Earth

Neutral

All Outputs controlled by one switchSwitched Live 1 Controls Outputs 1 to 6

Switched Live 2*Switched Live 1*

Switched Live 2 Controls Outputs 7 to 12

Link

Option 2Option 1

Note: If Presence Detectors are fitted to Any Output Connector

Switched Live Connections Must Not be made.

LN

L2

L1

30

LL1 NL2

Un-switched Live

L2 NL1 L

Neutral

Earth

Spectrum System

Installation GuideJunction Box

P1 AXPL1202 Document AID1027 Iss 1

Page 32: Installation Guide - ALC Lighting Controls

Switched LiveEarth

NeutralPermanent Live

Dimming 0V

Dimming Line

Output Connector Wiring

NL1

NL1

Input Control Wiring

The Dimming Pair can be connected

To a suitable Rotary Dimmer or Photocell

Note: To control All Outputs Link Dimming

For Emergency Test Purposes

The Permenant Live feed to

The Emergency Lamp Should

Permanent Live

NL1

Presence Detector (PD) Connector Wiring

NL1

Neutral

Earth

Switched Live

PD

Black

Grey

Black

Grey

Output Wiring

Dimming Line 2Dimming 0V 2

RATINGS MAX.

OUTPUTS 7 - 12

OUTPUT CONNECTOR WIRING

OUTPUTS 1 - 6

PER BOX

AX-PL1202

MOD LEVEL 1230V~ 50Hz 16A T45

230307/12345

DIMMING 0V

MAINTAINED LIVE

DIMMING

L

DIMMING

TERMINAL COMPARTMENT WIRING

SWITCHED

L1N

MAINS

1L2

LIVE

NEUTRAL

LIVE

EARTH

2

6A16A

NL2 L1 L L2 NL1 L

Dimming Line 1Dimming 0V 1

Permanent Live

PD

Neutral

Earth

Switched Live

Switched Live

Un-switched Live

Earth

Neutral

control of Outputs 1-6 and 7-12.

Presence Detector with Override Switch OFF facility.

addition of a second Presence Detector will give seperate* Duplication of this circuit by removal of Link and

(Controls All Outputs)

Link*

Grey

NL1

Black

NL1 Switched Live

Permanent Live

Dimming Line

Dimming 0V

Earth

Neutral

Emergency Test Output Connector Wiring

Pair 1 to Dimming Pair 2

Keyswitch

Be Wired Via a Keyswitch

0V 0V

Spectrum System

Installation GuideJunction Box

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXPL1202 Document AID1027 Iss 1

Page 33: Installation Guide - ALC Lighting Controls

White Tabs

Black Tab

Mechanical Fixing

100

114

160

90

Din Rail Fixing

Panel Mounting

Adaptable Boxes

Maximum M3.5/No.6

Fixing Size (3 Per LCM)

310

350

200

20

140

Maximum M4/No.10

Fixing Size (4 Per Box)

30

85

Spectrum System

Installation GuideDin Rail Output Lighting Control Module

P1 AXDN40ATDH Document AID1034 Iss 3

Page 34: Installation Guide - ALC Lighting Controls

Wiring

Dimming 0V (See Note)

Dimming Line

The dimming 0V is internally connected between each output connector.

Note:

Dimming Line

Dimming 0V (See Note)

Relay Output Pairs

Emergency Live In

Emergency Live Out

Earth

Neutral

Live

Neutral

Earth

Live

Live Out

Live Out

Live In

Live In

Live Out

Live In

Live In

Live Out

Dimming Line

Dimming 0V (See Note)

Dimming Line

Dimming 0V (See Note)

Dimming Pairs

LCM

Spectrum System

Installation GuideDin Rail Output Lighting Control Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXDN40ATDH Document AID1034 Iss 3

Page 35: Installation Guide - ALC Lighting Controls

INTRODUCTION

The AX-ETCS2 is intended for use with either 35w or 50w 12v low voltage tungsten halogen emergency luminaires and is designed to measure the current used to drive the lamp from the battery pack. It will operate on 12v or 6v DC battery packs where current drawn is between 2A & 5A.

LOCATION

The AX-ETCS2 is intended for mounting within the remote box of the emergency luminaire. It has plugs and sockets to suit most batteries, but can alternatively be wired into the battery output (+) wire using the terminal block provided.

The temperature of the lamp sensor shall not exceed 75 degreesCentigrade.

The maximum practical length of cable between light sensor and the Lighting Control Module is 30m.

TESTING/FAULTFINDING

Under emergency operation of the lamp, the current sensor read relay will close and give continuity. (This is monitored by the lighting control module input). Any failure of battery supply or lamp will be read by the system as a fault (during emergency test only).

Check for no continuity by removing the lamp (simulated failure) and powering off the normally unswitched live and switched live mains feed.

Upon replacing lamp, reintroduce mains there should again be no continuity.

SupplyLamp Invertor

Connectors

Battery

Lamp Sensor Coil

Terminal Block ( Cable tie in position to avoid strain on lamp sensor wires)

Input Plug to Spectrum LCM

0V IP2 IP1 +V

+

-

0V IP2 IP1 +V

+

-

Terminal Block

Lamp Sensor Coil

Maximum Length 30 metres Cable supplied by others)Run separately to mains cables (wiring is not polarity sensitive)

Spectrum System

Installation GuideLow Voltage Current Sensor

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AX-ETCS2 Document AID1035 Iss 1

Page 36: Installation Guide - ALC Lighting Controls
Page 37: Installation Guide - ALC Lighting Controls

White Tabs

Black Tab

Mechanical Fixing

100

61

106

90

Din Rail Fixing

Panel Mounting

198

310260

138

25

30

Adaptable Boxes

1 Way MTG22DN1

Fixing Size (4 Per Box)

Maximum M4/No.10

Maximum M3.5/No.6

Fixing Size (3 Per LCM)

Box Height Including Lid and Lid Screws 90mm

APEX LIGHTING CONTROLS

AX-ESI1

MOD LEVEL 1

230V~ 50Hz 8A T45

280703/12345

APEX LIGHTING CONTROLS

AX-ESI1

MOD LEVEL 1

230V~ 50Hz 8A T45

280703/12345

MAINS

MAINS INPUT

LL

SOLAR LEVEL

SWITCH ON/OFF

OUTPUT LED

POWER LED

STATUS LED

ADJUST TO SET

Li

OUTPUT

20mm HBC

NN

ON

Lo Li

FUSE 8A

2 2.00.5

0P

SENSOR

+V

0.5

0.5

4

3

0V

10.0

5.0

MINUTES

TO ON

0.51

0 0

TO OFF

0

0.5

MAINS

MAINS INPUT

LL

SOLAR LEVEL

SWITCH ON/OFF

OUTPUT LED

POWER LED

STATUS LED

ADJUST TO SET

Li

OUTPUT

20mm HBC

NN

ON

Lo Li

FUSE 8A

2 2.00.5

0P

SENSOR

+V

0.5

0.5

4

3

0V

10.0

5.0

MINUTES

TO ON

0.51

0 0

TO OFF

0

0.5

Spectrum System

Installation GuideExternal Solar Interface Unit

P1 AX-ESIU1 Document AID1036 Iss 1

Page 38: Installation Guide - ALC Lighting Controls

Wiring

0V

O/P

+V

Wiring to External Solar Sensor

Switched Live Out to Lights

Live Feed to Volt Free Output Relay

Adjust for Solar Level ON/OFF

Adjust to select time to OFF

Fused at 8 Amps

AP

EX

LIG

HT

ING

CO

NT

RO

LS

AX

-ES

I1

MO

DL

EV

EL

1

230

V~

50H

z8A

T45

280

70

3/1

2345

MA

INS

MA

INS

INP

UT

LL

SO

LA

RL

EV

EL

SW

ITC

HO

N/O

FF

OU

TP

UT

LE

D

PO

WE

RLE

D

ST

AT

US

LE

D

AD

JU

ST

TO

SE

T

Li

OU

TP

UT

20m

mH

BC

NN

ON

Lo

Li

FU

SE

8A

22.0

0.5

0P

SE

NS

OR

+V

0.5

0.5

43

0V

10.0

5.0

MIN

UT

ES

TO

ON

0.5

100

TO

OF

F

0

0.5

Spectrum System

Installation GuideExternal Solar Interface Unit

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AX-ESIU1 Document AID1036 Iss 1

Page 39: Installation Guide - ALC Lighting Controls

Mechanical Fixing

200

350 Including Lid310

140

20

30

Fixing Size (4 Per Box)

Maximum M4/No.10

Box Height Including Lid and Lid Screws 90mm

1

5A

2

5A

O/P1 O/P2

EMERGENCY

OUTPUT 2

LCM TOTAL

OUTPUT 1EM

3A13A

3A

5A

5A

L

EM

NL N +V

230V~ 50Hz 13A T45

STATUS LED

POWER LED

COMMS LED

0V0V 1 2 + -

280703/12345

MOD LEVEL 5

AXDN22ATDH

21 +V0V 0V21

Spectrum System

Installation GuidePartition Interface Unit

P1 AX-PIU1 Document AID1038 Iss 3

Page 40: Installation Guide - ALC Lighting Controls

Wiring

+ 1 2 3 4 Off -

Pa

rtiti

on

Sw

itch

Bo

un

d In

So

ftw

are

To

C

on

tro

l Bo

th O

/P1

& O

/P2

Sce

ne

S

witc

h

Pla

te 1

Sce

ne

S

witc

h

Pla

te 2

Co

nta

cts

LCM

1

Dia

gra

m s

ho

win

g lin

ka

ge

of

two

4 b

utt

on

an

d 0

ff s

ce

ne

sw

itch

pla

tes t

og

eth

er,

utilis

ing

a p

art

ion

sw

itch

(N

B:

With

pa

rtitio

n s

witch

op

en

ea

ch

sce

ne

sw

itch

pla

te

op

era

tes t

he

lig

htin

g in

its

in

div

idu

al ro

om

.W

ith

th

e p

art

itio

n s

witch

clo

se

d e

ith

er

sce

ne

sw

itch

pla

te

op

era

tes

the

lig

htin

g in

th

e c

om

bin

ed

ro

om

).

9 5

1

0 6

11 7

1

2 8

LCM

2

0V

IN

2 IN

1 +

V

+ 1 2 3 4 Off -

Co

il

Ma

ins

Re

lay

0V

IN

2 IN

1 +

V0

V IN

2 IN

1 +

V0

V IN

2 IN

1 +

V0

V IN

2 IN

1 +

V0

V IN

2 IN

1 +

V0

V IN

2 IN

1 +

V0

V IN

2 IN

1 +

V

Co

nta

cts

Spectrum System

Installation GuidePartition Interface Unit

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AX-PIU1 Document AID1038 Iss 3

Page 41: Installation Guide - ALC Lighting Controls

BLUE

YELLOW

-

WHITE

BLACK

ScreenGREEN

-

+

RED

Screen +

Spine Bus Connection From Area Controller

52.0

58.0

14.0

20.0

16.5

15.0

Fixing: 2 Number 20mm Long No.8 Screws Included

Wiring

Spectrum System

Installation GuideSpine Bus Extension Socket

P1 AX-SBE1 Document AID1037 Iss 1

Page 42: Installation Guide - ALC Lighting Controls

ControllerArea

SECOND FLOOR

GROUND FLOOR

FIRST FLOOR

Field Bus 3

Field Bus 2

Field Bus 1

ExtenderSpine Bus

Spine BusExtender

The Spine Bus extenders are typically mounted in the Riser cupboard for the floorsthat are connected to an Area Controller sited on a different floor.

These provide a connection point for the set up of the lighting on each seperate floor.

Typical Application

Spectrum System

Installation GuideSpine Bus Extension Socket

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AX-SBE1 Document AID1037 Iss 1

Page 43: Installation Guide - ALC Lighting Controls

Wiring

Mechanical Fixing

BLUE

YELLOW

0v Connection

WHITE

BLACK

PD Connection

GREEN

+V

+V Connection

RED

PD 0V

(Provided Continuity is Maintained Wire Colour is not Important)

52.0

58.0

14.0

20.0

16.5

15.0

Fixing: 2 Number 20mm Long No.8 Screws Included

Connection To/From Next Terminal Box

Spectrum System

Installation GuideSensor Extension Socket

P1 AX-PDE1 Document AID1039 Iss 1

Page 44: Installation Guide - ALC Lighting Controls

Typical Application

Lighting Control Module

JunctionBox

Ground Floor

Hard Wired

Stairwell

Sensor

JunctionBox

BoxJunction

First Floor

Second Floor

3 core 7/0.2 or Similar

Sensor

Sensor

Connection to

IN1/ON/PD

+V

0V

Hard Wired LCM

Spectrum System

Installation GuideSensor Extension Socket

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AX-PDE1 Document AID1039 Iss 1

Page 45: Installation Guide - ALC Lighting Controls

WHITE

RED

BLUE

YELLOW

0V

IN2/OFF/LS

IN1/ON/PD

+15VBLUE

GREEN

BLACK

YELLOW

RED

WHITE

IN2/OFF/LS

IN1/ON/PD

0V

2 WAY AND OFFRETRACTIVE SWITCHES

LATCHING SWITCHMOMENTARY SWITCH

IN2/OFF/LS

0V

PRESENCE DETECTOR

+V

IN1/ON/PD

0V

PRESENCE DETECTORWITH LIGHT SENSOR

IN2/OFF/LS

IN1/ON/PD

0V

PULL CORD

+V

3 CORES REQUIRED

2 CORES REQUIRED

3 CORES REQUIRED

4 CORES REQUIRED

Spectrum System

Installation GuideInput Connector Wiring

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 Document AID1040 Iss 1

Page 46: Installation Guide - ALC Lighting Controls
Page 47: Installation Guide - ALC Lighting Controls

STATUS LED

0V+V

0V

2

IN1-2

+

-

IN1-1

SCN

IN2-2IN2-1

Wiring

Mechanical Fixing

Fixing Size Maximum M4/No.8

Fixing Centres

OUTPUT 2

N

OUTPUT 1

L

N

L

1

STATUS LED

0V+V

0V

2

IN1-2

+

-

IN1-1

SCN

IN2-2IN2-1

For Switches requiring 2 wires connect between 0V & OffFor Switches requiring 3 wires connect between 0V,On & Off

In2/Off/LSIn1/On/PD

Input Wiring

+V

Output Wiring

Live Out 1

Neutral

Neutral

Live In

Live In

Earth

Earth

Live Out 2

In2/Off/LSIn1/On/PD

0V

Dimming 1

Dim 0V

Dimming 2Bus +

Bus Screen

Bus -

Back Row terminals Front Row Terminals

2

1

2

1

250

261

235

3348

36 37

1

PROGRAMSOCKET

Spectrum System

Installation GuideGear Tray Lighting Control Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXGT22ATDH Document AID1041 Iss 1

Page 48: Installation Guide - ALC Lighting Controls
Page 49: Installation Guide - ALC Lighting Controls

Fixing Size

Permenant Live 1Earth

NeutralPermenant Live 2

Input Mains and Communications Wiring

NL1

NL1

Mechanical Fixing

Alternative: Wieland 34.362.0211.1Order Code: AX-OPGST18

Output Connector Wiring

Dimming 0V

Dimming Line

270

92

51

252

57

23

9

230 Maximum M8 (No.14)

26

20

RATINGS MAX.

230V~ 50Hz 5A T45

MOD LEVEL 1

AXPL10DH

280703/12345

5A

5A

5A

LIVE 1

LIVE 2

DALI

Earth

Neutral

Live

ScreenBus -Bus +

Mains

Communications Bus

230V~ 50Hz 5A T45

280703/12345

MOD LEVEL 1

AXPL10DHINPUT

INPUT

BUS

MAINS

+

s

-

N

L

L

N

DALI

LIVE 2

WIELAND WS.032.6666.1N

LIVE 1

DALI -

FUSES 5A HBC2

1

LIVE 2

LIVE 1

NEUTRALEARTH

OUTPUT

DALI +

RATINGS MAX.

5A

5A

5A

Spectrum System

Installation GuideSingle Output Dali Lighting Control Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXPL10DH Document AID1044 Iss 1

Page 50: Installation Guide - ALC Lighting Controls
Page 51: Installation Guide - ALC Lighting Controls

White Tabs

Black Tab

Mechanical Fixing

100

61

106

90

Din Rail Fixing

Panel Mounting

198

310260

138

25

30

Adaptable Boxes

1 Way MTG22DN1

Fixing Size (4 Per Box)Maximum M4/No.10

Maximum M3.5/No.6

Fixing Size (3 Per LCM)

Box Height Including Lid and Lid Screws 90mm

MAINS ONMAINS INPUT

O/P

LL

4 3

+V-

0V

NN s +

BUS

OPEN DRAIN

12 24VSUPPLY

5V5V 0V

INPUT 1

+V 1 2 0V

RS232

0V TXRX

INPUT 2

1 0V2

PIN3 RXPIN2 TX

PIN5 0V

MAINS ONMAINS INPUT

O/P

LL

4 3

+V-

0V

NN s +

BUS

OPEN DRAIN

12 24VSUPPLY

5V5V 0V

INPUT 1

+V 1 2 0V

RS232

0V TXRX

INPUT 2

1 0V2

PIN3 RXPIN2 TX

PIN5 0V

MAINS ONMAINS INPUT

O/P

LL

4 3

+V-

0V

NN s +

BUS

OPEN DRAIN

12 24VSUPPLY

5V5V 0V

INPUT 1

+V 1 2 0V

RS232

0V TXRX

INPUT 2

1 0V2

PIN3 RXPIN2 TX

PIN5 0V

AXDN42RS232

MOD LEVEL 1

290110/12345

MAINS ONMAINS INPUT

O/P

LL

4 3

+V-

0V

NN s +

BUS

OPEN DRAIN

12 24VSUPPLY

5V5V 0V

INPUT 1

+V 1 2 0V

RS232

0V TXRX

INPUT 2

1 0V2

PIN3 RXPIN2 TX

PIN5 0V

AXDN42RS232

MOD LEVEL 1

290110/12345

Spectrum System

Installation GuideRS232 Interface Module

P1 AXDN42RS232 Document AID1046 Iss 1

Page 52: Installation Guide - ALC Lighting Controls

Wiring

AXDN42RS232

MOD LEVEL 1

290110/12345

Spectrum System

Installation GuideRS232 Interface Module

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AXDN42RS232 Document AID1046 Iss 1

Page 53: Installation Guide - ALC Lighting Controls

Wiring & Termination

Mechanical Fixing

LCM

To Current Sensor

LCM Input Terminal Block.

LED Driver

Blue (+V)Yellow (0V)

White (IN1/ON/PD)Red (IN2/OFF/LS or ET)

Maximum Length 30M

Outside of Luminaire

From any potentially

Allow Maximum Spacing

Secure to a suitable interior surfaceusing a double sided self adhesive pador cable tie (Not Supplied)

on the inside of the Luminaire.Ensure Minimum amount of Interface Cable

Sensor Cable AXCA05RJH

Hot Parts

Ensure Maximum Distance betweenCurrent Sensor &Other ElectronicParts of Luminaire

Sensor Cable AXCA05RJ

LCM Sensor Input Socket

(Types may vary)

Terminate to Detail shownOn individual LCM Wiring label.

Lighting Control Modules (LCM)

LCM NOTE:

The White wire (IN1) is not

be cut back to the end of therequired for operation so may

cable sleeve if no Park terminalis available.

Pluggable Interface Wired Interface

[See Note]

LED Display

+

-

+

-

12

12

ON

ON

12

12

ON

ON

Spectrum System

Installation GuideLED Current Sensor

P1 AX-ETDS1 Document AID1048 Iss 1

Page 54: Installation Guide - ALC Lighting Controls

ON

1 2

1 2

ON

1 2

ON

1 2

ON

Low Sensitivity

Medium Low Sensitivity

Medium High Sensitivity

High Sensitivity

Sensitivity Set Up

The sensitivity of the LED current sensor can be set to four different levels by setting the DIL switch accessed on the side of the unit, setting as below,

Note: The setting is dependant upon the type of fitting it is connected to, the position of the sensor coil and the DIL switch setting should be set as advised by ALC Lightng Controls.

Spectrum System

Installation GuideLED Current Sensor

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 AX-ETDS1 Document AID1048 Iss 1

Page 55: Installation Guide - ALC Lighting Controls

Mechanical Fixing

Mechanical Details

4931 4

1.0 mm Material

40/42 mm 45 mm

2 to 25 mmMaterial

Diameter Mounting Hole Diameter Mounting Hole

Highest Point nearest toExternal Bright Light Source

Wiring

Wiring shown connected to a typical Dali LCM however connection could be

to any point on the Dali Bus

Spectrum System

Installation GuideDali Sensor

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AXDS01SPL Document AID1049 Iss 1

Page 56: Installation Guide - ALC Lighting Controls
Page 57: Installation Guide - ALC Lighting Controls

This document outlines the steps to be taken to configure both the Lighting Control Module and the ceiling mounted Sensors. This setup should only be undertaken once the sytem components are in place and correctly wired and this document assumes that to be the case.

For details of system specification, wiring and installation see documents ALT1040, ALT1042 and AID1002.

Whilst not essential, the preffered method of set up is the Sensor first followed by the Lighting Control Module.

The Sensor used for Solar Control must be connected to Input Eight, Sensors used for Presence or Absense Detection can be fitted to any Input Five to Eight.

Inputs one, two and three are for the connection of local 2 way and Off retractive override switches that control each individual group e.g Input 1 controls Output Group 1etc.

The configuration transmitter referred to in the text is a hand held unit that can transmit various functions to the Sensors connected to Input Five to Eight of a Lighting Control Module, it is a Safety Extra Low Voltage Device that can be handled without the need for specialised safety precautions.

Typical Output Grouping

Infrared Transmitter (Shown Opened ready for use)

Transmit SwitchSwitch 6

Infra Red Transmitter LED

Transmit SwitchSwitch 4

Status LED (Flashes to show message being sent)

Mode Selector SwitchSwitch 2

1

2

3

4 5 6

7

8

9

I/P 1 I/P 2 I/P 3

Sensor(Default Position)

Group 2

Group 1 Group 3

Lighting Control Module

230Vac

I/P 4

INPUTS5 6 7 8

Spectrum Solo

Installation GuideInfra Red Programmer

P1 Document ALT1045 Iss 2

Page 58: Installation Guide - ALC Lighting Controls

SENSOR CONFIGURATION

The LCM attempts to maintain the light level by varying the 'solar enabled' outputs, calibratation of the light level sensor should be carried out using the following procedure.

1. Firstly set the sensor to operatate in Spectrum mode (Mode 3). To do this set the DIL switches on the configuration transmitter to the following diagram:

Whilst pointing the transmitter towards the sensor press and hold SW4 for 10 seconds, the sensor should acknowledge the command by flashing 3 times every 2 seconds for 20 seconds.

NOTE: if the sensor LED illuminates continuously the Sensor is locked. To unlock the sensor set all the DIL switches to OFF (see diagram)and within 30 seconds after Sensor power up push and hold SW6 for 10 seconds whilst pointing the transmitter at the sensor. The sensor should rapidly flash to acknowledge that the unlock code has been received. After unlocking the sensor return back to the beginning of item 1.

2. Using the wall switches adjust each of the output groups to achieve the desired lighting level. Adjusting the levels will temporary suspend any solar control therefore allowing the light sensor to be accurately setup.

3. Ensure sensor is set to operate in Spectrum mode as described at item 1, Press and hold SW6 on the configuration transmitter for 10 seconds whilst pointing it towards the sensor. The sensor LED will flash with equal ON/OFF time (this indicates that the sensor is auto-calibrating), during this process stand well away from the sensor to minimise the affect of reflected light on the sensor. Once sensor calibration is complete the sensor LED will stop flashing (this process can take up to 3 minutes).

4. OPTIONAL. To lock the sensor and prevent any unintentional alterations, set all the DIL switches to OFF (see diagram) press and hold SW6 for 10 seconds whilst pointing the transmitting LED towards the sensor. The sensor LED should illuminate continuously for about 5 seconds and then flash its current mode (i.e. mode 3) a couple of times.

NOTE: For best results light sensor calibration should be at night with blinds shut in a fully furnished room.

Lighting Control Module (LCM) CONFIGURATION

1. On the configuration transmitter, set all 4 DIL switches ON (see diagram) and then press and hold SW4 for 10 seconds whilst pointing the transmitting LED towards the sensor. T h e outputs should flash to acknowledge that the LCM has entered the configuration mode and the COMMS LED on the LCM should be flashing once a second. After the outputs have flashed they should all remain on. In this state, output groups at 100% brightness are solar controlled, whilst output groups dimmed to 10% are not.

NOTE: If the outputs don't flash and the Lighting Control Module COMMS LED is continuously lit, the LCM is locked, the configuration mode can then only be accessed within 5 minutes after power-up.

2. To select which output groups are to be solar enabled or disabled select the desired group by means of the DIL switches in the Configuration Transmitter, (see diagrams) pressing either SW4 to enable or SW6 to disable solar control for that group. The output groups will change between 10% (disabled) and 100% (enabled).

3. For movement detection mode set DIL switches as shown, press SW4 for presence and SW6 for absence mode, the outputs will flash to acknowledge this command. At this point the LCM is operating in Presence/Absense test mode and the functionality can be checked.

NOTE: In absence mode the user will have to press the wall switches to bring the lights on once the 10 second time out has occured. The COMMS LED on the LCM should be flashing twice a second in this mode.

4. Set the DIL (see diagram) press SW4 to exit the LCM configuration mode or SW6 to exit and lock the LCM. The LCM will then restart, if locked the configuration mode can only be accessed within 5 minutes of power-up and the COMMS LED will be continuously on.

4321

4321

4321

4321

43214321 4321

Group 1 Group 2 Group 3

4321

4321

4321

Spectrum Solo

Installation GuideInfra Red Programmer

Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P2 Document ALT1045 Iss 2

Page 59: Installation Guide - ALC Lighting Controls

+V

0V

In2/Off/LS

In1/On/PD

Wiring

Mechanical Fixing

Lighting Control ModuleInput 1

Lighting Control ModuleInput 2

Lighting Control ModuleInput 3

Lighting Control ModuleInput 4

86

86

35mm Deep Single Wall Box

Secure Switch Plate through Switch Assemblyto back box using 2 off M3.5 Screws(Supplied In Packing Box)

View On Rear of Switch Assembly

The Comm and OFF connection can be taken toany of the LCM Inputs.

In1/On/PD

In2/Off/LS

0V

+V

In1/On/PD

In2/Off/LS

0V

+V

In1/On/PD

In2/Off/LS

0V

+V

4OFF0V

23

1

4

O

2

3

1

Spectrum System

Installation Guide5 Button Scene Setting Switch

ALC Lighting Controls Tel: +44 (0)1923 495630 www.alclightingcontrols.co.uk20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AX-SP5B-IL Document AID1054 Iss 1

Page 60: Installation Guide - ALC Lighting Controls
Page 61: Installation Guide - ALC Lighting Controls

Wiring

Mechanical Fixing

86

86

35mm Deep Single Wall Box

Secure Switch Plate through Switch Assemblyto back box using 2 off M3.5 Screws(Supplied In Packing Box)

View On Rear of Switch Assembly

The Comm and OFF connection can be taken toany Input associated with an ON connection.

DOWNUP

4OFF0V

23

1

In1/On/PD

In2/Off/LS

+V

0V

+V

In1/On/PD

In2/Off/LS

0V

+V

In1/On/PD

In2/Off/LS

0V

Input 1Lighting Control Module

LCM 2

Input 3Lighting Control Module

Input 4Lighting Control Module

0V

+V

In1/On/PD

In2/Off/LS

0V

+V

In2/Off/LS

In1/On/PDInput 1Lighting Control Module

Lighting Control ModuleInput 2

LCM 1

Spectrum System

Installation Guide7 Button Scene Setting Switch

ALC Lighting Controls Tel: +44 (0)1923 495630 www.alclightingcontrols.co.uk20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796Watford, Herts, WD18 8JA, UK. Email: [email protected]

P1 AX-SP7B-IL Document AID1055 Iss 1

Page 62: Installation Guide - ALC Lighting Controls