For more information please contact www.silenceair.com [email protected] +61 2 9555 7215 Patents and Patents Pending Silenceair is a registered trademark of Silenceair International Pty Limited 140mm Acoustic Wall Ventilator Installed in Hebel Panel wall system INSTALLATION GUIDE - 10-02-01/ 1 13 75 50 92 140 2 390 SILENCEAIR 140 SUGGESTED 200mm BELOW F.C.L TO AVOID CORNICES 13mm PLASTERBOARD 140mm ACOUSTIC VENTILATOR FIXED TO STUD WORK 92mm STEEL STUD AND INSULATION OFFSET SARKING AROUND SILENCEAIR UNIT 50mm TOP HATS AND CAVITY HEBEL PANEL SILICON SEAL AROUND ALL SIDES OF THE SILENCEAIR UNIT 150mm X 50mm CUTOUT TO HEBEL PANEL 200mm X 100mm WEATHER LOUVRE AND SPRAY CUP INSERTED INTO SILENCEAIR UNIT INTERIOR ADJUSTABLE LOUVRE INTERIOR EXTERIOR

Transcript of INSTALLATION GUIDE. 10-02-01/ 1 - 140mm standard Z / hebel …€¦ · Only the face of the...

Page 1: INSTALLATION GUIDE. 10-02-01/ 1 - 140mm standard Z / hebel …€¦ · Only the face of the pre-painted weather louvre is visible. • The weather louvres can be factory painted to

For more information please contactwww.silenceair.com [email protected] +61 2 9555 7215

Patents and Patents Pending Silenceair is a registered trademark of Silenceair International Pty Limited

140mm Acoustic Wall Ventilator Installed in Hebel Panel wall system

INSTALLATION GUIDE - 10-02-01/ 1

1375 50 92

140 2

390

SILENCEAIR140

SUG

GES

TED

200

mm

BEL

OW

F.C.L

TO

AVO

ID C

ORN

ICES

13mm PLASTERBOARD

140mm ACOUSTIC VENTILATORFIXED TO STUD WORK

92mm STEEL STUD AND INSULATION

OFFSET SARKING AROUNDSILENCEAIR UNIT

50mm TOP HATS AND CAVITY

HEBEL PANEL

SILICON SEAL AROUND ALL SIDESOF THE SILENCEAIR UNIT

150mm X 50mmCUTOUT TO HEBEL PANEL

200mm X 100mmWEATHER LOUVRE AND SPRAY CUPINSERTED INTO SILENCEAIR UNIT

INTERIOR ADJUSTABLE LOUVRE

EXTERIORINTERIOREXTERIORINTERIOR

Page 2: INSTALLATION GUIDE. 10-02-01/ 1 - 140mm standard Z / hebel …€¦ · Only the face of the pre-painted weather louvre is visible. • The weather louvres can be factory painted to

For more information please contactwww.silenceair.com [email protected] +61 2 9555 7215

Patents and Patents Pending. Silenceair is a registered trademark of Silenceair International Pty Limited

150

50

140

35

3

21

4

• Locate the Silenceair unit on the inside face of the Hebel panel in the desired fixing location. The Silenceair unit has clear instructions written on it for the correct orientation of the unit.

• Mark the position of the external vent opening on the Hebel panel to line up with the external vent opening on the Silenceair unit.

• Screw fix the Silenceair unit into position through the 92mm stud or directly onto the Hebel panel. The unit is robust and can be screwed or glued into position without affecting the performance of the unit.

• Seal around the edges to ensure a close fit to the Hebel panel.

• Cut a 150mm wide * 50mm high opening in the Hebel panel for the external weather louvre.

• Mark the location of the interior vent opening onto the plasterboard interior lining.

• Fix the interior plasterboard sheet into position.• Cut a 140mm * 35mm high hole in the plasterboard.

Ensure the cut-out in the plaster board lines up with the interior opening in the Silenceair unit.

• Fix the interior adjustable louvre into place on the plasterboard after the wall has been painted.

Page 3: INSTALLATION GUIDE. 10-02-01/ 1 - 140mm standard Z / hebel …€¦ · Only the face of the pre-painted weather louvre is visible. • The weather louvres can be factory painted to

For more information please contactwww.silenceair.com [email protected] +61 2 9555 7215

Patents and Patents Pending. Silenceair is a registered trademark of Silenceair International Pty Limited

6

7

5

• The Silenceair unit is completely hidden in the wall.• Only the face plate of the interior adjustable louvre is

visible.

• When the exterior face of the Hebel panel has been painted, insert the pre-painted Silenceair exterior weather louvre and spray cup into the cut-out and ensure the weather louvre and spray cup are correctly inserted into the Silenceair unit.

• Ensure the weather louvre and spray cup are in the correct orientation (Louvres facing down).

• Fix into place.

• Silenceair reserves the right to modify or reissue technical brochures without notice.

• © 2017 Silenceair International Pty Ltd. ABN 44 096 462 949

• Date of Publication: August 2017.

NOTES

• The Silenceair unit is completely hidden inside the wall cavity. Only the face of the pre-painted weather louvre is visible.

• The weather louvres can be factory painted to colour match the colour scheme of the building. Call us to discuss lead times to ensure there is adequate notice prior to the removal of the scaffolding.