Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet...
Transcript of Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet...
![Page 1: Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet the requirements of directives EMC 89/336/EEC and are tested according to EN 55014-1,](https://reader034.fdocuments.in/reader034/viewer/2022051811/60260846b432615e9a31b3f0/html5/thumbnails/1.jpg)
Are designed for both energy saving and improving indoor air quality. Using aluminium air-to-air plate type heat exchangers, they are able to work with a range of residential, commercial and industrial air-conditioning applications. Heat exchangers with high conductivity, crossflow or counterflow construction enable efficiencies of up to 85% when transferring heat from warm to cold air streams.
SIMX VHR Heat Recovery Units come with in-built filtration.
SIMX VHR Heat Recovery Units have fully insulated cabinets giving excellent sound and thermal insulation properties.
SIMX VHR Heat Recovery Units come standard with electronic controllers that have:
• Both On/Off and automatic functions.• 5 different speeds for each fan (supply and exhaust).• Manual or automatic control for optionally installed electric heaters.• BMS capability (relevant Gateway required).
Cross section airflow diagram of unit in cooling mode SIMX Heat Recovery controllerElectric Duct Heater (VCE)
SIMX electrical heaters have TSEK certification, CE marked and GOST-R certification.
Technical specifications meet the requirements of directives EMC 89/336/EEC and are tested according to EN 55014-1, EN 61000-3-2/3-3 for EMC.
Electrical heaters are produced in single or three phase upon request in standard spiral duct dimensions. The heaters have overheat devices.
Heaters can be controlled manually by an SEC Controller or automatically by an FEC Controller.
PUB1154 Iss04 05/15
Simx VHR Heat Recovery Units
Technical Specifications for VHR Models
SIMX MODELVHR04 P
VHR 07 P
VHR 09 P
VHR11 P
VHR16 P
VHR20P
VHR29
VHR36
VHR51
Order Code FAN4450 FAN2468 FAN2445 FAN2469 FAN5536 FAN2441 FAN2442 FAN4402 FAN2447
Air Flow 0 Pa* l/s 110 170 235 300 410 550 700 880 1000
Air Flow 150 Pa* l/s 60 120 175 235 350 490 595 750 780
Efficiency % Efficiency up to 70%, depending on working conditions
ELE
CT
RIC
AL Voltage 230V / 50Hz
Motor Power Watt 120 170 270 310 450 1000 1100 1100 1472
Maximum current A 0.50 0.80 1.20 1.40 2.05 4.5 11.0 11.0 12.0
Air Filter Synthetic Filter – For Exhaust and Fresh Air
OP
TIO
NA
L
Electrical Heater or Heater for Hot Water
90/70°CkW
2 230V1~
2 230V1~
3230V1~
3230V1~
4400V3~
5400V3~
7400V3~
10400V3~
12400V3~
Simx Heat Recovery UnitsCross Flow Non Permeable
Installation Details
Connection Schematic
Drain outlet
Connection Duct L = 2 D (min)
Inside Fresh Air
Inside Exhaust Air
Inside Fresh AirInside Exhaust Air
Cable length: 10m
[email protected] | [email protected] | www.simx.com.au
![Page 2: Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet the requirements of directives EMC 89/336/EEC and are tested according to EN 55014-1,](https://reader034.fdocuments.in/reader034/viewer/2022051811/60260846b432615e9a31b3f0/html5/thumbnails/2.jpg)
Airflow - External Static PressureDimensions for VHR Models
Unit measurement guide
Exhaust
Fresh air Exhaust
Fresh air
Indoor Outdoor
Fresh Air
ExhaustFresh Air
Exhaust
INDOOR
OUTDOOR
S
VencoVHR04 P
VHR 07 P
VHR09 P
VHR 11 P
VHR16P
VHR20P
VHR29
VHR36
VHR51
Length (mm) L 800 900 900 940 1115 1115 1400 1450 1650
Width W 740 860 860 1020 1030 1030 980 1100 1160
Height (mm) H 295 335 335 450 430 430 420 595 690
Duct Ød Ø160 Ø200 Ø200 Ø250 Ø300 Ø300 Ø355 Ø400 Ø450
Weight (kg) 28 40 40 63 65 70 104 145 160
Dimensions of connection (mm)
W1 180 215 215 250 255 255 235 260 285
W2 195 225 225 270 265 265 240 245 270
W3 180 215 215 250 255 255 265 305 345
W4 195 225 225 270 265 265 240 245 270
Service Clearance S 400 450 450 500 550 550 450 450 500
L W
H
L W
H
H
LW
VHR 15 - 51VHR 04 P - 11 P
H
WL
0
50
100
150
200
250
300
350
400
0 200 400 600 800 1000 1200
External Sta+c Pressure pa
Airflow l/s
VHR51 5
4
3
2
1
Fan Speed key
Air Flow [l/s] Air Flow [l/s]
Air Flow [l/s] Air Flow [l/s]
Air Flow [l/s] Air Flow [l/s]
Air Flow [l/s] Air Flow [l/s]
Air Flow [l/s]
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
Exte
rnal
sta
tic p
ress
ure
0
50
100
150
200
250
300
0 20 40 60 80 100 120
External Sta+c Pressure
Airflow l/s
VHR04P
120 0
50
100
150
200
250
300
350
400
0 50 100 150 200
External Sta+c Pressure
Airflow l/s
VHR07P
50 100 150 200 250 300 350 400 450 500
External Sta+c Pressure
Airflow l/s
0
100
200
300
400
500
600
0 50 100 150 200 250
External Sta2c Pressure
Airflow l/s
VHR09P
250 0
100
200
300
400
500
600
700
0 50 100 150 200 250 300
External Sta+c Pressure
Airflow l/s
VHR11P
VHR20
0
100
200
300
400
500
External Sta+c Pressure
Airflow l/s
0
100
200
300
400
500
600
700
800
0 50 100 150 200 250 300 350 400 450 500
External Sta2c Pressure
Airflow l/s
VHR16P
0
100
200
300
400
500
0 200 400 600 800 1000
External Sta+c Pressure
Airflow l/s
VHR36
0 50
100 150 200 250 300 350 400 450 500
0 100 200 300 400 500 600 700 800 External Sta+c Pressure
Airflow l/s
VHR29
0
200
400
600
800
1000
0 100 200 300 400 500 600
Ext
erna
l Sta
tic P
ress
ure
Airflow l/s
VHR20P