Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet...

2
Are designed for both energy saving and improving indoor air quality. Using aluminium air-to-air plate type heat exchangers, they are able to work with a range of residential, commercial and industrial air-conditioning applications. Heat exchangers with high conductivity, crossflow or counterflow construction enable efficiencies of up to 85% when transferring heat from warm to cold air streams. SIMX VHR Heat Recovery Units come with in-built filtration. SIMX VHR Heat Recovery Units have fully insulated cabinets giving excellent sound and thermal insulation properties. SIMX VHR Heat Recovery Units come standard with electronic controllers that have: Both On/Off and automatic functions. 5 different speeds for each fan (supply and exhaust). Manual or automatic control for optionally installed electric heaters. BMS capability (relevant Gateway required). Cross section airflow diagram of unit in cooling mode SIMX Heat Recovery controller Electric Duct Heater (VCE) SIMX electrical heaters have TSEK certification, CE marked and GOST-R certification. Technical specifications meet the requirements of directives EMC 89/336/EEC and are tested according to EN 55014-1, EN 61000-3-2/3-3 for EMC. Electrical heaters are produced in single or three phase upon request in standard spiral duct dimensions. The heaters have overheat devices. Heaters can be controlled manually by an SEC Controller or automatically by an FEC Controller. PUB1154 Iss04 05/15 Simx VHR Heat Recovery Units Technical Specifications for VHR Models SIMX MODEL VHR 04 P VHR 07 P VHR 09 P VHR 11 P VHR 16 P VHR 20P VHR 29 VHR 36 VHR 51 Order Code FAN4450 FAN2468 FAN2445 FAN2469 FAN5536 FAN2441 FAN2442 FAN4402 FAN2447 Air Flow 0 Pa* l/s 110 170 235 300 410 550 700 880 1000 Air Flow 150 Pa* l/s 60 120 175 235 350 490 595 750 780 Efficiency % Efficiency up to 70%, depending on working conditions ELECTRICAL Voltage 230V / 50Hz Motor Power Watt 120 170 270 310 450 1000 1100 1100 1472 Maximum current A 0.50 0.80 1.20 1.40 2.05 4.5 11.0 11.0 12.0 Air Filter Synthetic Filter – For Exhaust and Fresh Air OPTIONAL Electrical Heater or Heater for Hot Water 90/70°C kW 2 230V 1~ 2 230V 1~ 3 230V 1~ 3 230V 1~ 4 400V 3~ 5 400V 3~ 7 400V 3~ 10 400V 3~ 12 400V 3~ Simx Heat Recovery Units Cross Flow Non Permeable Installation Details Connection Schematic Drain outlet Connection Duct L = 2 D (min) Inside Fresh Air Inside Exhaust Air Inside Fresh Air Inside Exhaust Air Cable length: 10m [email protected] | www.simx.co.nz [email protected] | www.simx.com.au

Transcript of Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet...

Page 1: Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet the requirements of directives EMC 89/336/EEC and are tested according to EN 55014-1,

Are designed for both energy saving and improving indoor air quality. Using aluminium air-to-air plate type heat exchangers, they are able to work with a range of residential, commercial and industrial air-conditioning applications. Heat exchangers with high conductivity, crossflow or counterflow construction enable efficiencies of up to 85% when transferring heat from warm to cold air streams.

SIMX VHR Heat Recovery Units come with in-built filtration.

SIMX VHR Heat Recovery Units have fully insulated cabinets giving excellent sound and thermal insulation properties.

SIMX VHR Heat Recovery Units come standard with electronic controllers that have:

• Both On/Off and automatic functions.• 5 different speeds for each fan (supply and exhaust).• Manual or automatic control for optionally installed electric heaters.• BMS capability (relevant Gateway required).

Cross section airflow diagram of unit in cooling mode SIMX Heat Recovery controllerElectric Duct Heater (VCE)

SIMX electrical heaters have TSEK certification, CE marked and GOST-R certification.

Technical specifications meet the requirements of directives EMC 89/336/EEC and are tested according to EN 55014-1, EN 61000-3-2/3-3 for EMC.

Electrical heaters are produced in single or three phase upon request in standard spiral duct dimensions. The heaters have overheat devices.

Heaters can be controlled manually by an SEC Controller or automatically by an FEC Controller.

PUB1154 Iss04 05/15

Simx VHR Heat Recovery Units

Technical Specifications for VHR Models

SIMX MODELVHR04 P

VHR 07 P

VHR 09 P

VHR11 P

VHR16 P

VHR20P

VHR29

VHR36

VHR51

Order Code FAN4450 FAN2468 FAN2445 FAN2469 FAN5536 FAN2441 FAN2442 FAN4402 FAN2447

Air Flow 0 Pa* l/s 110 170 235 300 410 550 700 880 1000

Air Flow 150 Pa* l/s 60 120 175 235 350 490 595 750 780

Efficiency % Efficiency up to 70%, depending on working conditions

ELE

CT

RIC

AL Voltage 230V / 50Hz

Motor Power Watt 120 170 270 310 450 1000 1100 1100 1472

Maximum current A 0.50 0.80 1.20 1.40 2.05 4.5 11.0 11.0 12.0

Air Filter Synthetic Filter – For Exhaust and Fresh Air

OP

TIO

NA

L

Electrical Heater or Heater for Hot Water

90/70°CkW

2 230V1~

2 230V1~

3230V1~

3230V1~

4400V3~

5400V3~

7400V3~

10400V3~

12400V3~

Simx Heat Recovery UnitsCross Flow Non Permeable

Installation Details

Connection Schematic

 

Drain outlet

Connection Duct L = 2 D (min)

Inside Fresh Air

Inside Exhaust Air

Inside Fresh AirInside Exhaust Air

Cable length: 10m

[email protected] | [email protected] | www.simx.com.au

Page 2: Installation Details Simx Heat Recovery Units...GOST-R certification. Technical specifications meet the requirements of directives EMC 89/336/EEC and are tested according to EN 55014-1,

Airflow - External Static PressureDimensions for VHR Models

Unit measurement guide

 

Exhaust  

Fresh  air   Exhaust  

Fresh  air  

Indoor  Outdoor  

Fresh Air

ExhaustFresh Air

Exhaust

INDOOR

OUTDOOR

S

VencoVHR04 P

VHR 07 P

VHR09 P

VHR 11 P

VHR16P

VHR20P

VHR29

VHR36

VHR51

Length (mm) L 800 900 900 940 1115 1115 1400 1450 1650

Width W 740 860 860 1020 1030 1030 980 1100 1160

Height (mm) H 295 335 335 450 430 430 420 595 690

Duct Ød Ø160 Ø200 Ø200 Ø250 Ø300 Ø300 Ø355 Ø400 Ø450

Weight (kg) 28 40 40 63 65 70 104 145 160

Dimensions of connection (mm)

W1 180 215 215 250 255 255 235 260 285

W2 195 225 225 270 265 265 240 245 270

W3 180 215 215 250 255 255 265 305 345

W4 195 225 225 270 265 265 240 245 270

Service Clearance S 400 450 450 500 550 550 450 450 500

 L  W  

H  

L   W  

H  

H

LW

VHR 15 - 51VHR 04 P - 11 P

H

WL

0  

50  

100  

150  

200  

250  

300  

350  

400  

0   200   400   600   800   1000   1200  

External  Sta+c  Pressure  pa  

Airflow  l/s  

VHR51   5

4

3

2

1

Fan Speed key

Air Flow [l/s] Air Flow [l/s]

Air Flow [l/s] Air Flow [l/s]

Air Flow [l/s] Air Flow [l/s]

Air Flow [l/s] Air Flow [l/s]

Air Flow [l/s]

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

Exte

rnal

sta

tic p

ress

ure

0  

50  

100  

150  

200  

250  

300  

0   20   40   60   80   100   120  

External  Sta+c  Pressure  

Airflow  l/s  

VHR04P  

120  0  

50  

100  

150  

200  

250  

300  

350  

400  

0   50   100   150   200  

External  Sta+c  Pressure  

Airflow  l/s  

VHR07P  

50  100  150  200  250  300  350  400  450  500  

External  Sta+c  Pressure  

Airflow  l/s  

0  

100  

200  

300  

400  

500  

600  

0   50   100   150   200   250  

External  Sta2c  Pressure  

Airflow  l/s  

VHR09P  

250  0  

100  

200  

300  

400  

500  

600  

700  

0   50   100   150   200   250   300  

External  Sta+c  Pressure  

Airflow  l/s  

VHR11P  

VHR20  

0  

100  

200  

300  

400  

500  

External  Sta+c  Pressure  

Airflow  l/s  

0  

100  

200  

300  

400  

500  

600  

700  

800  

0   50   100   150   200   250   300   350   400   450   500  

External  Sta2c  Pressure  

Airflow  l/s  

VHR16P  

0  

100  

200  

300  

400  

500  

0   200   400   600   800   1000  

External  Sta+c  Pressure  

Airflow  l/s  

VHR36  

0  50  

100  150  200  250  300  350  400  450  500  

0   100   200   300   400   500   600   700   800  External  Sta+c  Pressure  

Airflow  l/s  

VHR29  

0

200

400

600

800

1000

0 100 200 300 400 500 600

Ext

erna

l Sta

tic P

ress

ure

Airflow l/s

VHR20P