FOREWORD / QUALITY PHILOSOPHY

You have chosen a SPARTHERM ebios-fire. Thank you for your confidence in our technology.

In a world characterised by excess and mass production, the good name of our firm is inextricably linked to the credo of our owner, Gerhard Manfred Rokossa:

“High technical quality combined with modern design and on-site customer service carried out to the latter’s full satisfaction, in the expectation that the customer will then recommend us to others.”

Together with our partners at specialist dealerships, we offer first-class products that stir the emotions, evoking feelings of security and comfort. However, to ensure that we achieve this, we recommend that you read the operating manual carefully to quickly familiarise yourself with your decora-tive fire in all its details. In addition to information on how to use it, this manual also contains important maintenance and operating instructions for your safety and to ensure your ebios-fire retains its value, as well as useful tips.

If you have any further questions, please contact your dealer.

A beautiful fire at all times.

Your SPARTHERM TeamG.M. Rokossa

Page 3: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 3

CONTENTS

1. General Information 41.1 Scope of Supply 5

2. Installation Instructions 52.1 Functional description 52.2 Technical data 62.3 General Requirements for Installation 62.4 Installation location 72.5 Assembly / installation 72.6 General instructions for installation in custom-made furniture 82.6.1 Minimum dimensions for furniture 92.6.2 Fire precautions/minimum distances from walls 102.7 General instructions for installation in custom-built open fireboxes/

fireplaces 112.7.1 Minimum dimensions for custom-built firebox 112.7.2 Fire precautions/minimum distances for custom-built fireplaces 122.8 Combustion Air Supply 13

3. Operating Instructions 133.1 General Operating Information 133.2 Fire precautions 143.3 Fuel 143.4 Using the unit for the first time 153.4.1 Assembly and installation 153.4.2 Starting the ebios-fire 163.4.3 Checks when using the fire for the first time 173.5 Refuelling/changing the canister 173.6 Switching off safely 18

4. Maintenance, cleaning and care 184.1 Unit and glass soot up heavily, quickly and unevenly 194.2 Unpleasant smell 194.3 Flame pattern changes 194.4 Burner fails to light 194.5 The burner goes out suddenly 19

5. General warranty terms and conditions 195.1 Scope of Application 195.2 General information 195.3 Warranty period 205.4 Requirement of effectiveness for the warranty 205.5 Warranty exclusions 205.6 Defect remediation / repairs 205.7 Extension of warranty 205.8 Spare parts 215.9 Liability 215.10 Note 21

6. Dimensioned drawings 21

7. Designer / distributor product information for fireplaces with individual ebios Quadra Inside Automatic SL burners 22

8. Declaration by the installer of a custom-made decorative fireplace with an ebios Quadra Inside Automatic SL bioethanol burner as an individual component 23

Page 4: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 4

IMPORTANT NOTE

Pursuant to the German Equipment and Product Safety Act (GPSG) and our statutory duty to draw attention to the heat generated by this product, please note the following:

The calorific value of 96% ethanol is approx. 29,600 kJ/kg. With a fuel throughput of 0.5 l/h (approx. 0.4 kg/h) the heat released is approx. 3,300 W (Quadra Inside Automatic I SL). The Quadra Inside AutomaticI II SL con-sumes 1 l/h and the resulting combustion heat is 6,600 W.

However, please note that a generous fresh air supply is necessary when operating the decorative fireplace, as otherwise the carbon dioxide gener-ated will exceed the permissible concentration in the ambient air.

The incoming fresh air is usually cooler than the ambient air to be heated, resulting in a loss of energy. The effective heat output from a bioethanol fire is thus very low, and so decorative fireplaces burning bioethanol are not considered to be heating systems.

This is a decorative fireplace that is not intended for heating or continuous operation. Nevertheless, it should be taken into account that heat is gener-ated as a by-product of the combustion process. This can cause increased heating in the room where the fireplace is installed. Read the safety instruc-tions and measures for rear ventilation carefully.

Please note the information and warnings given in this operating manual.

1. GENERAL INFORMATION

Young children, the elderly and the frail: As with all naked flames, a guard should be used to protect the above. Risk of burns! Never leave such individuals unsupervised near an ebios-fire when it is lit or when the fire has just gone out. ebios-fires must always be operated under supervision!

Your ebios-fire should be installed and operated in accordance with the relevant national and local regulations, in particular the fire safety regula-tions of the particular federal state or the fire protection regulations of the VKF (Switzerland).

Ensure that your ebios-fire is set up on a stable base and select an instal-lation location where the burner will not be exposed to movement due to impacts, etc., when in operation.

Please note that you should never top up with fuel manually by pouring it into the fire tray by hand. Fuel is always supplied to the fire directly from the canister, via the integral pump!

Only persons familiar with the appliance and the safety instructions and who have been trained how to operate the fire should be allowed to change the fuel canister.

The ebios-fire is not a heater. It is a decorative fire. Sufficient ventilation must be provided. The appliance switches off automatically after 8 hours for safety reasons.

Bioethanol is a hazardous substance and the quantities you may store are subject to regulations. It is essential to comply with the regulations that apply at the place of use.

Page 5: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 5

For homes in Germany the general rule is:

Storage in the basement: not more than 20 litresStorage in the living-room: not more than 5 litres

(Source: Hazardous Substances Information Data Sheet published by the Association of the Raw Materials and Chemical Industry; also Technical Rules for Flammable Fluids 20)

1.1 SCOPE OF SUPPLY

ebios-fire with the following characteristics:

• Quadra Inside Automatic I SL or II SL casing with stainless steel fire tray • Burner support frame (not in conjunction with other ebios burner mount-

ing products)• 2 x canister closing systems with hose connection• 2 x inlet hoses (standard length: 2.5m / Optional: up to 10 metres)• Ignition remote control• Tabletop power unit with a 1.8 metre length of cable

2. INSTALLATION INSTRUCTIONS

Please carefully read and note the following instructions. Remember that bioethanol is a liquid fuel that can generate high temperatures when burned and which is itself highly flammable. You should also bear in mind that the brightness of the flame can dim to a level at which the flame is no longer clearly visible. Please make children and other people in the home aware of this. Failing to follow the installation and operating instructions can result in dangerous situations and the possibility of explosive ignition of the fuel.

Correct installation and proper handling are essential to ensure safe, reliable operation of your fire. The unit is not self-supporting. It must be installed as per the instructions, ensuring it is horizontal. Never move the burner when the unit is operating. The unit must be installed in such a way that it cannot be knocked over or tilted.

2.1 FUNCTIONAL DESCRIPTION

Once the burner is supplied with an operating voltage, it can go into opera-tional readiness mode by actuating the switch on top of the burner. The remote control is then used to initiate the combustion process. During this phase, a pump is operating all the time, and glow ignition is triggered once the level is high enough. At this point, the burner channel fills with fuel that then ignites.

The integrated pumps continue delivering fuel to the burner channel until the level reaches the fill level sensor. At this time, the pumps are switched off.

The level falls as the fuel burns. When the fuel is no longer in contact with the level sensor, the pumps start up again and continue pumping until the level reaches the sensor again.

Only one pump is in operation at any one time. That helps keep the power consumption low.

When the burner is switched on, the pump that was delivering fuel the last time it was switched off is activated first.

The burner is supplied with two sets of fuel lines for operation with two canisters. First of all, pump 1 empties canister 1. Then the system switches over to pump 2 and canister 2. Always make sure the burner is switched off before exchanging an empty canister for a full one.

Page 6: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 6

If the canister(s) is/are empty, the flame will go out and the burner will switch off. Additional an audible fault signal will be heard.

Otherwise, the pumps can be stopped by switching off the burner (using the remote control). The fuel remaining in the burner channel at that time is pumped back into the tank. The remaining ethanol burns off within about 40 seconds.

2.2 TECHNICAL DATA

Quadra Inside Automatic I SL

Quadra Inside Automatic II SL

Fuel type: Bio-Ethanol(96% ethanol content)

Fuel consumption ca. 0,5l/h ca. 1,0l/h

Combustion output 3300 W 6600 W

Minimum room volume per burner **

air change values 0,2 h-1* 418 m³ 836 m³

air change values 0,5 h-1* 167 m³ 334 m³

air change values 1 h-1* 84 m³ 168 m³

permissible atmospheric humidity max. 60 % rel.

permissible ambient temperature 0 - 40 °C

permissible mains voltage 110 - 230 VAC

max. power consumption ca. 36 W

** At a maximum burning time of 5 hours. This information refers exclu-sively to the combustion air requirement for the ebios fireplace. If air is also consumed by other sources in the room such appliances must be considered separately.

** The following air change values are quoted as a rough guide 1):

Air change (l/h) Note

0…0,5 Windows and doors closed

0,3…1,5 Window tilted, no shutters

5…10 Window half open

1) Recknagel, Sprenger, Schrameck: Heizung+Klimatechnik, Oldenbourg Verlag

2.3 GENERAL REQUIREMENTS FOR INSTALLATION

All relevant national and European standards and local regulations (storage and fire precautions, etc.) must be noted and observed when installing and operating the ebios-fire. The following is a list of the relevant regulations (without any claim to completeness). They refer only to operation in Ger-many. In other countries the regulations that apply there must be observed.

BetrSichV Industrial Safety and Health Ordinance

TRbF Technical Rules for Flammable Fluids

BsV The fire protection requirements of the particular federal state

LBO State building regulations

GefStoffV Hazardous Substances Ordinance

The ebios-fire should only be installed in rooms and at locations where the position, structural conditions and type of use will not create any hazards. The floor area of the room where it is installed must be of such a type and size that the ebios-fire can be correctly operated in accordance with the regulations.

Only approved and sufficiently strong handling aids should be used to trans-port your ebios-fire. There must be no fuel in the fire tray during transport.

Page 7: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 7

DAMAGE IN TRANSIT Please contact your supplier without delay. Protect the cover and visible parts of your fire from dirt and damage during installation and transport

We recommend that you keep a suitable fire extinguisher for liquid fires handy (fire class B).

2.4 INSTALLATION LOCATION

When choosing the installation location for your ebios-fire please ensure the unit is not directly exposed to major heat sources such as radiators, stoves, etc. and that it is not installed in a room where high temperatures occur (e.g. a sauna).

Your ebios-fire must not be installed:

1. In stairwells and landings, except in residential buildings with no more than two flats

2. In corridors accessible to the public3. In garages 4. In rooms where highly flammable or explosive substances or mixtures

are processed, stored or manufactured in such quantities that ignition or explosion would be hazardous.

5. In poorly ventilated spaces 6. In unsupervised areas accessible to the public 7. In areas not sufficiently protected from cross-draughts 8. On top (uninstalled) of tables, furniture, up against a wall, etc.9. Outdoors without a protection against weather and high humidity 10. In the entrance areas of hotel lobbies where draughts are likely to be

more prevalent, and where substantial differences in air pressure can be expected.

When setting up the ethanol canister it is important to ensure that it cannot tip over. The canister should only be stored in bays or cupboards where

flammable gases cannot build up. There must be no sources of ignition in the immediate vicinity of the ethanol canister and supply lines. Please note that the ethanol canisters must be placed at a lower level than the burner (not more than 4 m difference in height), as otherwise there may be an uncontrolled escape of ethanol if a leak occurs. Therefore keep the lines as short as possible (line length not more than 10 m) and protect the lines from contact with sharp, pointed or rough objects.

If using the ebios-fire 5-litre canister, the canister storage space must be not less than 350 mm x 180 mm x 240 mm (H x W x D) per canister. In addi-tion, the design of the location must ensure that it does not allow flammable gases to build up, it will contain any escaping ethanol and it will prevent fire from spreading.

2.5 ASSEMBLY / INSTALLATION

The ebios-fire Quadra Inside Automatic I SL and II SL is a ready-to-use unit for fitting into the top plate of a custom-made piece of furniture (flammable materials) or a custom-built open fireplace (non-flammable materials).

Custom-built open fireplaces using the Quadra Inside Automatic I SL or II SL do not require a flue.

Whether free-standing or wall-mounted, the ebios-fire unit must be aligned horizontally and secured so that it cannot tip. The wall-mounted model should be attached to the wall and the free-standing model should be fas-tened to the wall or floor. Note the safety clearances (Fig. 10 radiant area).

Rear vents must not be closed or obstructed. Place the burner in the frame provided in the Quadra Inside Automatic I SL oder II SL. The floor on which free-standing units are placed must have sufficient load-bearing capacity. If not, appropriate measures should be taken, e.g. using a board to spread the load, in order to achieve the requisite safe loading capacity.

Page 8: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 8

Suitable fasteners should be used for wall-mounting (e.g. wall dowels, screws, etc.).

Modifications to the design or construction of the Quadra Inside Automatic I SL oder II SL are NOT permissible.

2.6 GENERAL INSTRUCTIONS FOR INSTALLATION IN CUSTOM-MADE FURNITURE

• When sell ing an ebios Quadra Inside Automatic for installation in a custom-made piece of furniture, the installer must first accept and sign the product information for this type of installation (refer to sections 7 and 8).

• The basic design of a custom-made piece of furniture for installation of a Quadra Inside Automatic I SL oder II SL normally comprises at least a top plate/tabletop and a housing space including the air supply. For tabletop installation a housing space is not necessary, but it is advisable.

• When installing the fire in a custom-made piece of furniture (flammable materials), it is essential to ensure that the Quadra Inside Automatic I SL or II SL is NOT installed in a recess in the furniture. Fire hazard!

• The space above the Quadra Inside Automatic I SL or II SL must be clear of all objects, all the way up to the ceiling (ceiling clearance >1,000 mm).

• The Quadra Inside Automatic I SL or II SL should only be installed in the top plate or tabletop of a piece of furniture (for example: chest of drawers, sideboard, pull-out unit, table).

• The furniture should always be permanently attached to the wall or floor and secured against accidental moving, knocking over and/or lifting. Suitable fastening material should be used.

• All air inlets and rear vents must be kept clear and never blocked, as otherwise a build-up of heat may occur. Fire hazard!

Page 9: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 9

• The minimum clear section for the air supply in a piece of furni ture is 200 cm² / 400 cm² (Quadra Inside Automatic I SL / II SL). The rear vents should be dimensioned accordingly.

• The area underneath the Quadra Inside Automatic I SL or II SL housing (housing space, Fig. 1) must not be used for storage. The storage space and the housing space should be physically separated by a false floor and a back wall.

1 Quadra Inside Automatic I SL or II SL 5Air inlet 200 cm² / 400 cm² (I SL / II SL)

2 Top plate / tabletop 6 Rear vent

3 Housing space 7 Wall anchor

4 Storage space 8 Levelling foot, if necessary

2.6.1 MINIMUM DIMENSIONS FOR FURNITURE

Fig. 1 Example of pull-out unit

Fig. 2a Minimum dimensions of top plate / tabletop Quadra Inside Automatic I SL with frame

Fig. 2b Minimum dimensions of top plate / tabletop Quadra Inside Automatic II SL with frame

Page 10: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 10

2.6.2 FIRE PRECAUTIONS/MINIMUM DISTANCES FROM WALLS

When positioning the custom-made furniture unit next to a non-flammable wall, a minimum distance of 150 mm from the wall must be maintained at the rear and at the side. The point of reference is the outer edge of the Quadra Inside Automatic I SL or II SL housing (see Fig. 4 and 5).

• A minimum distance of 1,000 mm from combustible building compo-nents, furniture, decorations or curtains must be maintained at the sides (see Fig. 7) to ensure sufficient protection from heat.There must be no objects between the top of the ebios-fire unit and the ceiling of the room (min. 1,000 mm) (see Fig. 6)!

Fig. 6 Minimum distance from ceiling

There must be no objects above the burner.

Fig. 7 Minimum distances from flammable building components

Fig. 4 Minimum distances from a non-flammable wall

Fig. 5 Minimum distances in the corner of a room

Page 11: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 11

2.7 GENERAL INSTRUCTIONS FOR INSTALLATION IN CUSTOM-BUILT OPEN FIREBOXES/FIREPLACES

• A custom-built open fireplace normally consists of the firebox, the hous-ing space with air supply and the insulation or, if applicable, facing.

• The firebox must NOT be closed by a firebox door.• All air inlets and rear vents must be kept clear and never blocked, as

otherwise a build-up of heat may occur. Fire hazard!• The minimum clear section for the air supply in a piece of furni-

ture is 200 cm2 / 400 cm² (I SL / II SL). The rear vents should be dimensioned accordingly.

• The base plate of the firebox (with a cut-out for the Quadra Inside Auto-matic I SL or II SL) should be adequately dimensioned.

2.7.1 MINIMUM DIMENSIONS FOR CUSTOM-BUILT FIREBOX

• The firebox width is a minimum of 905 mm (Quadra Inside Automatic I SL) or 1405 mm (Quadra Inside Automatic II SL), depending on the burner length.

• The firebox height is a minimum of 600 mm.• The firebox depth has been fixed at a minimum of 460 mm.• The distance from the front edge of the firebox to the housing frame has

been fixed at a minimum of 150 mm. • The housing space width is a minimum of 250 mm. • The free cross-section for the air inlet opening in the housing

space is a minimum of 200 cm2 / 400 cm2.• The ethanol canister storage space must be at least the size indicated

in section 2.4.

Fig.9a Minimum firebox dimensions

min. 905 / 1405 (I SL / II SL)

min

. 600

Front version Version open on three sides

Double-sided versionLeft corner version

Right corner version Fig. 8 Open fireplace versions

Page 12: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 12

1 Outer covering

2 Mineral wool insulation (to AGI-Q 132) t ≥ 60 mm

3 Vermiculite or calcium silicate board t ≥ 40 mm

4 Firebox

5 Air inlet opening 200 cm² / 400 cm² (I SL / II SL)

6 Housing space

7 Quadra Inside Automatic Brenner

8 Protective glass

• Note: The air inlet aperture (5) can be at the front, back, side and left or right of the fire area. The important thing is that the free air cross section is complied with to assure optimum cooling for the appliance.

• The firebox should be constructed of vermiculite boards or calcium sili-cate boards with a minimum material thickness of 40 mm. The material must carry a general building inspectorate approval issued by Deutsches Institut für Bautechnik Berlin (DIBt) as proof of its suitability for use as firebox cladding.

• The thermal insulation should be made from matting, slabs or sheeting made of silicate insulating materials (stone, slag and ceramic fibres) in building material class A1 to DIN 4102 Part 1 with a maximum service temperature of at least 700 °C when tested according to DIN 52271 and a nominal bulk density of 80 kg/m3. It must have a correspond-ing insulation code number in accordance with AGI-Q 132 (the thermal insulation material thickness data indicated in Figs. 9a and 9b refer to mineral wool to AGI Q 132).

• It is important to ensure that incoming air can flow freely to the housing space. The minimum free cross-section for the air inlet is 200 cm2 / 400 cm2. Corresponding air inlet openings should be provided.

2.7.2 FIRE PRECAUTIONS/MINIMUM DISTANCES FOR CUSTOM-BUILT FIREPLACES

Fig. 10 Minimum distances from flammable building components

Fig.9b Minimum firebox dimensions with frame

Page 13: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 13

2.8 COMBUSTION AIR SUPPLY

Your ebios-fire draws the air it needs to burn from the room in which it is installed (non-room air sealed). You must ensure that the room where the fire is installed has an adequate supply of fresh air. If the windows and doors are sealed (for example, for energy-saving reasons) it may be the case that an adequate fresh air supply cannot be guaranteed. That is why it is essential that you note the required air change rate and comply with the room sizes indicated. Otherwise, your well-being (headaches, poor concen-tration) and, possibly, your safety may be compromised or the fire may not burn properly. For protection from these hazards you can purchase devices in specialist shops similar to a smoke alarm that warn you when exces-sive carbon dioxide concentrations occur. Air quality indicators that analyse carbon dioxide concentration as well as temperature are also advisable.

Open a window to ensure an adequate supply of fresh air.

3. OPERATING INSTRUCTIONS

Read these Installation and Operating Instructions through carefully before installing or operating your ebios-fire. Remove all objects from the fire tray of the ebios-fire Quadra Inside Automatic SL. Please note all fire precau-tions and dangerous goods provisions.

3.1 GENERAL OPERATING INFORMATION

• Young children, the elderly and the frail: As with all naked flames, a guard (available from specialist dealers as an accessory) should be used to protect the above. Risk of burns! Never leave such individuals unsupervised near an ebios-fire when it is lit or when the fire has just gone out. Please make them aware of this hazard.

• Never place flammable objects on any part of the ebios-fire Quadra Inside Automatic I SL und II SL. Never dry washing on the unit. Racks for drying washing should always be placed outside the radiant area of the fire (Fig. 10). Fire hazard!

• The burning process releases thermal energy which heats up the burner, the housing surfaces, the glass windows (depending on the model) and the protective glass. Avoid touching hot parts unless appropriate precautions are taken (e.g. wear protective gloves). Risk of burns!

• Never leave the fire unsupervised when lit!• Please ensure that the protective glass (if supplied) is fitted to the

Quadra Inside Automatic I SL and II SL. • We recommend that you open a window whenever the fire is in use.• Operating more than one decorative ethanol fireplace at the same

time is permissible only if the fuel throughput of all the units does not exceed the permitted value according to local regulations. Adequate ventilation must also be ensured. For more information please refer to the table under Technical Data 2.2 on page 6.

• Modifications to ebios-fire units are not permissible.• This is a decorative fireplace for home use which is not designed for

heating and is not intended for continuous operation. It should never-theless be noted that heat is produced as a by-product of combustion. That can increase the heat in the room where the fire is used.

• If the burner is not going to be used for some time we recommend that you close the ethanol canister by screwing on the lid and remove the mains adaptor from the socket outlet.

Page 14: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 14

• NEVER fill the burner by pouring in fuel at the side or on top DANGER TO LIFE

• Handling fuel near the unit when lit or while still hot is dangerous and must be avoided. Please remember that a static charge is enough to create a spark which can ignite the fuel.

• Any accidental spills of ethanol should be cleared up straight away – before lighting the burner!

• The burner is suitable for indoor use only. It must not be used out of doors or in a draughty place

• The burner may only be operated within an ambient temperature range of +15°C to +35°C.

• High atmospheric humidity and condensation forming on the burner may interfere with its operation. In that case, switch the unit off if lit, or do not use it.

• You should bear in mind that the brightness of the flame can dim to a level at which the flame is no longer clearly visible. Please make children and other people in the home aware of this.

• Do not smoke when handling fuel or the ebios-fire.

Failure to follow these basic rules can result in uncontrolled ignition and even an explosion!

3.2 FIRE PRECAUTIONS

Do not place any flammable objects, such as decorations, clothing, etc., in the radiant area. A minimum distance of 1,000 mm must be maintained from flammable building compo-nents, furniture, decorations or curtains at the sides to protect them properly from heat. The

space above the fire must be clear of all objects, all the way up to the ceiling (ceiling clearance 1,000 mm)!

3.3 FUEL

The fuel used is bioethanol (chemical formula C2H

6O) with a 96,6% ethanol

content. You can purchase the fuel from your specialist dealer. The fuel is a hazardous substance according to ADR: Class 3 PG II, UN 1170.

Never use any other type of fuel, such as petrol, spirit or flammable fluids. Do not mix fuels together or mix fuel with other substances. The burners must only be operated with the fuel that we specify. Otherwise, the warranty will be voided and operating the unit may be unsafe or dangerous.

Ethanol is a highly flammable fluid which must be stored in a tightly closed container in a cool place, protected from light and kept away from sources of ignition. Please remember that a static charge can create a spark. It is permissible to store up to 5 litres in the living-room and up to 20 litres in the basement*. Keep bioethanol out of the reach of children.

Please note that ethanol is intended only for burning - it is not a food product. Keep children safe! If ethanol is swallowed, seek medical treatment without delay. Show the doctor the label from the fuel canister.

* (Source: Hazardous Substances Information Data Sheet published by the Association of the Raw Materials and Chemical Industry; also Technical Rules for Flammable Fluids 20)

1000 mm

Page 15: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 15

3.4 USING THE UNIT FOR THE FIRST TIME

The ebios-fire-Quadra Inside Automatic I SL and II SL is supplied with the fuel feed lines empty, to prevent any leakage or evaporation of ethanol in transit.

Important notes when using the unit for the first time:

• The circular cut-outs on the long side of the burner housing must be left open. They must not be closed off or restricted. These are the air inlets.

• The height adjustment screws must always be accessible.• The height adjustment screws only have a limited adjustment range. If

you are unable to level the unit correctly by means of the screws, then use a structural solution (e.g. lining the base of the frame) in order to achieve a satisfactory result.

• The first time the unit is used, the fuel lines are still empty. There may not yet be enough ethanol in the fire tray if the ignition timing is erratic.

• Take care not to bend the lines sharply when connecting and installing them. Avoid pinching or chafing them and avoid tensile stress!

• Do not attach the lines to the outside of the burner. Allow them to hang freely.

• Pull gently on the quick-action couplings to check that they are securely engaged with the filling adapters.

• Check all the feed line connections to make sure the hose clip is cor-rectly positioned. It should not be possible to detach the fuel lines from the nozzles with a gentle pull.

• The ethanol canisters should always be placed below the level of the burner or fire tray. Never place the canisters above fire tray level.

• The unit should only be plugged into a socket that has been installed by a qualified electrician. The socket outlet must be easily accessible and it must be provided with a switch.

3.4.1 ASSEMBLY AND INSTALLATION

1. The first step is to connect the fuel feed lines (supplied) to the burner. You will need a standard pair of universal pliers or pointed pliers to do this. Push the ends of the fuel lines on to the connecting nozzles on the underside of the burner (Fig. 1), as far as they will go. Now squeeze the clips and slide them over the connecting nozzle and fuel line. When the pliers are released, the hose clip will hold the fuel line securely on the nozzle (Fig. 2). The ends of the fuel lines should now be securely attached to the burner. The lines can be connected in any order.

2. Connect the small, round, low voltage plug on the wall power supply to the burner. The plug will only fit the socket provided. The socket is located at the end of the burner diagonally opposite the fuel line con-nection side (Fig. 3).

3. Then place the Quadra Inside Automatic I SL or II SL in the ready-made cut-out in the top plate/tabletop. Start by inserting the mounting frame into the recess. Then place the burner in the mounting frame so that it rests on the bolts in the corners (Fig. 4).

Fig. 1 Fig. 2

Fig. 3

Page 16: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 16

7. Plug the wall power supply into a socket outlet.

3.4.2 STARTING THE EBIOS-FIRE

1. Switch on at the socket outlet, or press the top button on the radio remote control once (Fig. 8). To switch off, press the same button again.

2. Press the top button on the remote control (Fig. 9). To switch off, press the same button again.

3. The red illuminated ring on the switch on the top of the burner lights up. The burner then beeps twice briefly, then starts the filling process. Initially, the ethanol collects in the middle of the burner channel where it is ignited when the level is high enough. Wait until there is no further pump action, and until the ignition interval ends.

• Never bend your head directly over the burner channel, especially during the ignition phase.

• Remain at a safe distance of 1 metre until the appliance has ignited the fuel.

Take care not to pinch or damage the fuel lines or the power lead. Check that the burner insert is horizontal and ensure that the circular cut-outs on the burner housing (at the left and right of the long side) are unobstructed and not covered over.• Using a spirit level, please only check if the burner is horizontal while

the unit is cold.• The height adjustment screws must be accessible at all times.• The adjustment path of the height adjustment screws is limited. If no

satisfactory levelling is possible in this way, construction measures (e.g. extra filling below the installation frame) must be employed to improve the installation situation.

4. Remove the screw caps from the full ethanol canisters. Next, screw the filling adapters on to the canister. The end of the line with the metal intake nozzle should lie on the bottom of the canister, so that the canis-ter can be completely emptied.

5. Connect the fuel intake lines to the filling adapters via the quick action coupling. (Fig. 5)

6. Place the glass panes supplied in the slots on the top. (Fig. 6)

Fig. 6

Fig. 8 Fig. 9

Fig. 4

Fig. 5

Page 17: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 17

• Especially while the fuel is cold, the flames are barely visible to begin with. As the burner channel heats up, the flames get higher and brighter.

4. If the fuel level is significantly higher at one end of the fire tray than the other when the unit is warm, you should readjust the adjustment screws with the aid of the Allen key.

• Do not adjust while the unit is in burning mode. Never bend directly over the burner channel.

5. The ignition interval ends automatically after a short period. If the fuel has not burned off by then, switch off the appliance, wait for 10 seconds, then switch it back on again. This then starts a new ignition sequence.This can occur during initial start-up, and after extended periods when the system has not been in use. If no fuel is directed into the burner channel, even after this second attempt, or if the fuel does not ignite, switch off the appliance. Remove the mains power connector from its socket and contact After-Sales Service.

Note: a temperature switch is installed in the appliance that measures the temperature of the burner channel. If you operate and then switch off the appliance, it takes approx. 15 – 20 minutes until the appliance can be switched back on again. This is in the interest of your own safety. During this phase, the red LED on the operating switch flashes. Once the cooling phase has been reached, the burner issues an acoustic signal and the LED stops flashing.

FOR YOUR OWN SAFETY DO NOT ATTEMPT TO LIGHT THE BURNER BY HAND!!!

3.4.3 CHECKS WHEN USING THE FIRE FOR THE FIRST TIME

If you do not have a checklist for this, please answer the following questions:

• Is the unit undamaged?• Are the accessories complete?• Is there a sufficient air flow during the installation process?• Have all the specified clearances (safe distances) been observed?• Have the canisters been placed below the burner level?• Are all the fuel lines and connections leak-tight?• Is the operating indicator working (red ring on switch)?• Does the ethanol flow into the fire tray?• Do both pumps work? (The second pump will not switch on until the first

canister is empty)?• Does the ethanol spread out evenly over the whole fire tray?• Is the flame pattern even?• Are the temperatures of the surrounding surfaces non-critical? (Meas-

ure, if necessary).

3.5 REFUELLING/CHANGING THE CANISTER

• Do NOT fill the burner via the fire tray! • When changing the canister, keep as far away as possible from hot parts

and sources of ignition! DANGER TO LIFE!

Unscrew the cap from the new, full canister (Fig. 10). Detach the quick-action coupling from the fuel line at the canister (Fig. 11) and unscrew the lid and the end of the fuel line from the empty canister. Pull the filling adapter up and out of the empty canister (Fig. 12) and lower the intake hose into the full canister (Fig. 13).Screw the filling adapter on to the top of the full canister (Fig. 14). Re-attach the quick-action coupling to the filling adapter (Fig. 15).

Page 18: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 18

4. MAINTENANCE, CLEANING AND CARE

• Allow the unit to cool down for at least 1 hour before cleaning it!• Inspect and clean the unit once a month.

Various deposits build up in the fire tray over time. These can be loosened with a paintbrush/ordinary brush or a cloth when the unit is cold and then removed from the fire tray with a vacuum cleaner. It is important always to keep the fire tray clean and free from loose particles, as dirt and particles may interfere with the level control system.Surrounding surfaces and the slotted cover plate may become stained after ethanol has been burned for some time. These residues may be wiped off with a damp cloth when the unit is cold (do not use microfibre cloths on the glass panes of the unit).Dust must be removed regularly, as dust particles can burn or char. This can cause soot and dirt in the room where the fire is installed and on the furnishings in the room.After cleaning the unit, carry out the following checks to make sure the unit is in full working order.

• Check that all fuel lines, canisters and connections are leak-tight • Check condition of fuel lines • Examine the unit for any signs of damage or warping • Check that the air inlets are clean and unobstructed • Function of the remote control and the pumps

3.6 SWITCHING OFF SAFELY

To shut down the unit safely, unplug the power supply from the socket and press the switch on the burner or the top button on the remote control.

After a few seconds the red LED indicating that the unit is operating will go out. The remaining ethanol in the fire tray should burn off in about 5 to 10 minutes. If the unit is not going to be used for some time, remove the fuel lines from the canisters before switching off, and then wait for the signal that both canisters are empty. That ensures that the fuel lines have been drained as much as possible. Then seal the canisters with a leakproof cap (not the filling adapter). Remove the quick-action couplings from the filling adapters.

Fig. 10 Fig. 11

Fig. 12 Fig. 13

Fig. 14 Fig. 15

Page 19: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 19

4.1 UNIT AND GLASS SOOT UP HEAVILY, QUICKLY AND UNEVENLY

If this has not always been the case, please check the following:

• Is the correct fuel being used? • Is there a draught in the room?

4.2 UNPLEASANT SMELL

• Is there fuel in the fire tray although the burner is not lit? • Was any fuel spilled when refuelling? • Is there adequate ventilation?• Are there any particles or other foreign matter in the fire tray?• Is this smell also evident when using other types of ethanol?

4.3 FLAME PATTERN CHANGES

• Is the correct fuel being used? • Have all the safe distances been observed? • Is the room where the fire is installed sufficiently ventilated?• Is the installation location shielded from cross-draughts?• Are the circular air inlet holes unobstructed?• Is the unit more or less horizontal or is the ethanol distributed over the

whole length of the fire tray?

4.4 BURNER FAILS TO LIGHT

• Is the ring on the switch showing red?• Is there ethanol in the canisters?• Can you see from the fuel supply lines that ethanol is being pumped

through them? Is there ethanol in the fire tray?

4.5 THE BURNER GOES OUT SUDDENLY

• The burner switches off automatically after 8 hours to prevent it being inadvertently left on. (The red ring round the switch is still lit and the unit can be restarted).

• Has there been a power supply failure? The Quadra Inside Automatic I SL and II SL has to be restarted after a power failure.

• Has the burner been correctly installed, and have the air supply and vent openings been provided as per the instructions?

• The Quadra Inside Automatic I SL and II SL switches off if the housing becomes too hot to prevent overheating. The red light on the switch goes out and the unit must be allowed to cool down before it can be restarted.

5. GENERAL WARRANTY TERMS AND CONDITIONS

5.1 SCOPE OF APPLICATION

These General Warranty Terms and Conditions apply to the relationship between the manufacturer, Spartherm Feuerungstechnik GmbH, and the dealer/ intermediary. They are not the same as the contract and warranty terms and conditions which the dealer/intermediary passes on or may pass on to its customers in a particular case.

5.2 GENERAL INFORMATION

This quality manufactured product is state of the art.The materials used were meticulously selected and are constantly checked, as is our entire production process Setting up or installing this product requires special ized knowledge. Our products may therefore only be installed and commissioned by specialized firms and in compliance with statutory regulations as amended.

Page 20: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 20

• Use of unsuitable or unspecified fuel. The recommended fuel for your ebios-fire is bioethanol with a concentration of more than 96%, mar-keted by Spartherm Feuerungstechnik GmbH.

• Incorrect transport and/or storage• Careless handling of breakable parts such as glass and ceramics• Improper handling and/or use• Improperly fuelling the unit• Lack of maintenance • Lack of maintenance• Failure to follow the installation and operating instructions• Unauthorized modifications to the unit

5.6 DEFECT REMEDIATION / REPAIRS

Notwithstanding the statutory guarantee, which shall take precedence over our warranty during the statutory guarantee periods, within the scope of our warranty we will remedy free of charge all defects demonstrably due to a material fault or manufacturing error, provided that the other terms and conditions of this warranty undertaking are observed. In accordance with this warranty undertaking Spartherm Feuerungstechnik GmbH reserves the right either to rectify the defect or to replace the unit free of charge. Rectification of defects shall take precedence. This warranty undertaking expressly does not cover further compensation exceeding the statutory guarantee.

5.7 EXTENSION OF WARRANTY

In the case of performance in accordance with the terms of the warranty, whether remediation of defects or replacement of a unit, the warranty period shall be extended in respect of the replacement unit/ components.

5.3 WARRANTY PERIOD

The General Warranty Terms and Conditions apply only within the Federal Republic of Germany and the European Union. The warranty period and scope of the warranty in accordance with these terms and conditions shall apply apart from the statutory guarantee, which remains unaffected.

Spartherm Feuerungstechnik GmbH offers a 24-months’ warranty on ebios-fire units (stand-alone and inserts). Spartherm Feuerungstechnik GmbH offers a 6-months’ warranty on wearing parts in the area of the fire, such as wicks, burner mats, gaskets and ceramics.

5.4 REQUIREMENT OF EFFECTIVENESS FOR THE WARRANTY

The warranty period starts on the date of delivery to the deal-er/intermedi-ary. This must be verified from a document such as an invoice with the dealer/intermediary’s confirmation of delivery. The warranty certif icate relating to the product must be produced by the claimant when making a warranty claim. If such proof is not produced Spartherm Feuerungstechnik GmbH shall not be obliged to honour the warranty.

5.5 WARRANTY EXCLUSIONS

The warranty does not cover:• Product wear:

Wick / burner mat due to thermal load• Surfaces:

Discolouration of the paintwork or the galvanised surfaces of the fire unit and/or the burner due to thermal load or overload.

• Glass: Dirt caused by soot or burned-on residues of burnt materials. Colour changes or other visual changes caused by thermal load.

Page 21: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 21

5.8 SPARE PARTS

No spare parts other than those produced or recommended by the manu-facturer shall be used.

5.9 LIABILITY

Damage and compensation claims not based on a defective unit supplied by Spartherm Feuerungstechnik GmbH are excluded and are not covered by the warranty undertaking.This does not apply to statutory warranty claims arising in a particular case.

5.10 NOTE

Your specialist dealer/contractor will gladly advise and assist you in matters not covered by our warranty terms and conditions and undertakings. We particularly advise you to have your ebios-fire products serviced regularly by a stove fitter/specialist dealer. We reserve the right to make technical modifications and accept no liability for any errors.

6. DIMENSIONED DRAWINGS

Quadra Inside Automatic I SL with frame

Detail A

PLEASE NOTE: Keep this Manual in a safe place.Please keep this Manual in a safe place along with a valid, clearly dated purchase receipt and have them available for our service engineers.

Page 22: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB 22

7. DESIGNER / DISTRIBUTOR PRODUCT INFORMATION FOR FIREPLACES WITH INDIVIDUAL EBIOS QUADRA INSIDE AUTOMATIC SL BURNERS

ebios Quadra Inside Automatic burner systems comprise safe burners for decorative fireplaces burning bioethanol.

In all ebios Quadra Inside Automatic burner systems made by Spartherm Feuerungstechnik GmbH the liquid ethanol in the fire tray is at a distance from the ethanol supply in external canisters and is connected to it by fuel lines. The fire tray only ever contains a small quantity of combustible liquid, which burns away within 5-10 minutes.The design of the ebios Quadra Inside Automatic burner has been developed according to the state of the art. The burners have safety features guaran-teeing reliable, trouble-free operation.

Although the ebios Quadra Inside Automatic burner systems are designed to be decorative, they also give off heat as a by-product. Heat is produced by burning the ethanol. As well as creating the decorative flame, this process also generates heat of about 3,300 W (Quadra Inside Automatic I SL con-suming approx. 0.5 litres per hour) or 6,600 W (Quadra Inside Automatic II SL consuming approx. 1 litre per hour). Although the burners give off that heat, they are not heating appliances according to the regulations in force and they are not technically designed for that purpose.

Please read through the Installation and Operating Manual carefully, and in particular the safety notes and rear ventilation requirements, before initial installation of the ebios Quadra Inside Automatic burner system and before using it for the first time.

Proprietorship of the manufacture and design is expressly reserved and full legal protec-tion is claimed in accordance with Sections 823, 826 and 1004 of the German Civil Code. Unauthorized copying, distribution and reproduction, in full or in part, will be subject to civil and criminal prosecution under Sections 2 (7), 96 ff and 106 ff of the German Copyright Act and Sections 1, 3, 4, 18 and 19 of the Unfair Competition Act. Our General Terms of Sale and Delivery shall apply with regard to rights and their use. Proprietorship of the manu-facture and design is expressly reserved and full legal protection is claimed in accordance with Section 823 of the German Civil Code.

Quadra Inside Automatic II SL with frame

Detail B

Page 23: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

GB

GB 23

When designing fireplaces yourself, we recommend that you measure the temperatures in operation. Suitable contact thermometers or digital laser thermometers are available for this purpose, for example the VOLTCRAFT® IR 900-30S infrared thermometer, measuring range -50 to +900 °C. To make measurements for glass fireplace inserts (such as room dividers in spas and wellness centres or restaurants, hotels, etc.) you should attach suitable measuring points. Note the instructions in the user guide for your thermometer. If you are writing your own operating manuals for fireplaces of your own design using ebios Quadra Inside Automatic burner systems, please enter the results of your temperature measurements in the manuals and issue the customer / initial operator with a copy of your manual.

Individually installed fireplaces with ebios Quadra Inside Automatic burner systems must not be decorated with seasonal decorative items such as fairy lights, swags, garlands, etc. or Christmas or Easter decorations as these would block the air flow. Our Installation and Operating Manual can only provide information on the basic handling and operation of the ebios Quadra Inside Automatic burner and you should also include the special features of your finished product in your user manual.

The user instructions and safety instructions are an essential part of the contract of sale and are generally included in Spartherm Feuerungstechnik GmbH’s scope of supply.

If you have mislaid your copy, please contact us for a replacement.

8. DECLARATION BY THE INSTALLER OF A CUSTOM-MADE DECORATIVE FIREPLACE WITH AN EBIOS QUADRA INSIDE AUTOMATIC SL BIOETHA-NOL BURNER AS AN INDIVIDUAL COMPONENT

• The undersigned is solely responsible for the correct and safe operation of the unit.

• The undersigned confirms that he/she has read all the content of the enclosed product information and user instructions and has understood and noted them.

• The undersigned undertakes to produce a manual specifically for the decorative fireplace built by him/her using the ebios Quadra Inside Auto-matic burner and to issue a copy of that manual to the operator together with the decorative fireplace.

• The undersigned undertakes to give the user detailed instructions about using the decorative fireplace and also to point out the possible risks.

• The undersigned undertakes to give the user detailed instructions about using the decorative fireplace and also to point out the possible risks.

__________________ _____________________________Place, date Signature / stamp

Page 24: Installation and Operating Manual - media.druservice.nlmedia.druservice.nl/Documents/Data/IGH_Spartherm_2017-05_EN_Qua… · GB 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM

SPARTHERMDIE WELTMARKE FÜR IHR WOHNZIMMER

The Global brand for your living room | La référence mondiale pour votre salon | Il marchio mondiale per il vostro soggiorno

La marca mundial para su salón | Het merk van wereldformaat voor uw woonkamer | Światowa marka do Państwa salonu

Торговая марка № 1 для Вашего дома

D Ihr Fachhändler | UK Your specialist dealer | F Votre revendeur spécialiséIT Il vostro rivenditore specializzato | E Sus comercios especializados

NL Uw vakhandelaar | PL Państwa sprzedawca | РУС Ваш дилер

A1-S

P-G

B/0.

000/

05-2

017

SPARTHERM Feuerungstechnik GmbH · Maschweg 38 · D-49324 Melle Phone +49 (0) 5422 94 41-0 · Fax +49 (0) 5422 9441-14 · www.spartherm.com