Install Guide for MOD2, NA Petroleum Canopy Power Supply it · Install Guide for MOD2, NA Petroleum...

3
Install Guide for MOD2, NA Petroleum Canopy Power Supply Kit PN: 601074 (75 W), 601075-088 (88 W), 601075-105 (105 W), 601075 (150 W), with MODUS fixture. 601076 (200 W) with MODUS HO (High Output) fixture. PAGE 1 OF 3 IMPORTANT: PDL3 MODUS must only be used with 601074 (75 W) or 601075 (150 W) power supplies. PDL3 MODUS HO (High Output) must only be used with 601076 (200 W) power supply. PDL3 MODUS CANNOT be used with 601076 (200 W) power supply. NOTE: A LICENSED ELECTRICIAN SHALL MAKE ALL PRIMARY AND SECONDARY CONNECTIONS. Tools and supplies required: Cordless drill, adjustable end wrench (1.25 in/32 mm minimum opening), putty knife, tape measure, Phillips-head screwdriver, and twist-on or push-in UL Listed wire connectors for 14/18 AWG. 2. Install PDL3 MODUS: See PDL3 MODUS installation instructions. 1. Turn off power. 3. Remove any loose debris from around hole on top of canopy. Remove as much roof tar as possible in a 7" diameter circle around canopy hole, if present 5. Loosen gland fitting on power supply side of power module tube. Power module tube Power supply Gland fitting Enclosure lid PDL3 MODUS side 4. Assemble enclosure over top of installed fixture, making sure to tighten hex nut enough to compress gasket slightly. Wire from PDL3 MODUS Hub Lid Hex nut Gasket Installed PDL3 MODUS fixture Top of canopy Enclosure Enclosure QUICK REFERENCE PARTS GUIDE Enclosure cover Large hex nut Orange foam gasket Power Module tube Enclosure cover Ground wire Power supply Power Module tube Gland fittings Power Module Gland nut Gland nut Connector Cable gland Cable to PDL3 MODUS Cable to power supply O-ring Gray seal ring Attach power supply to enclosure cover with two self drilling sheet metal screws and speed nuts provided.

Transcript of Install Guide for MOD2, NA Petroleum Canopy Power Supply it · Install Guide for MOD2, NA Petroleum...

Page 1: Install Guide for MOD2, NA Petroleum Canopy Power Supply it · Install Guide for MOD2, NA Petroleum Canopy Power Supply it 31 60107 75 W , 601075-088 88 W , 601075-105 105 W , 601075

Install Guide for MOD2, NA Petroleum Canopy Power Supply Kit

PN: 601074 (75 W), 601075-088 (88 W), 601075-105 (105 W), 601075 (150 W), with MODUS fixture. 601076 (200 W) with MODUS HO (High Output) fixture.

PAGE 1 OF 3

IMPORTANT: PDL3 MODUS must only be used with 601074 (75 W) or 601075 (150 W) power supplies. PDL3 MODUS HO (High Output) must only be used with 601076 (200 W) power supply. PDL3 MODUS CANNOT be used with 601076 (200 W) power supply.

NOTE: A LICENSED ELECTRICIAN SHALL MAKE ALL PRIMARY AND SECONDARY CONNECTIONS.

Tools and supplies required: Cordless drill, adjustable end wrench (1.25 in/32 mm minimum opening), putty knife, tape measure, Phillips-head screwdriver, and twist-on or push-in UL Listed wire connectors for 14/18 AWG.

2. Install PDL3 MODUS: See PDL3 MODUS installation instructions.

1. Turn off power.

3. Remove any loose debris from around hole on top of canopy. Remove as much roof tar as possible in a 7" diameter circle around canopy hole, if present

5. Loosen gland fitting on power supply side of power module tube.

Power module tube

Power supply

Gland fitting

Enclosure lid

PDL3 MODUS

side

4. Assemble enclosure over top of installed fixture, making sure to tighten hex nut enough to compress gasket slightly.

Wire from PDL3

MODUS

Hub

Lid

Hex nut

GasketInstalled PDL3 MODUS fixtureTop of canopy

Enclosure

Enclosure

QUICK REFERENCE PARTS GUIDE

Enclosure cover

Large hex nut

Orange foam

gasket

Power Module

tube

Enclosure cover

Ground wire

Power supply

Power Module tube

Gland fittingsPower Module

Gland nut

Gland nut

ConnectorCable gland

Cable toPDL3

MODUS Cable topower supply

O-ringGray

seal ring

Attach power supply to enclosure cover with two self drilling sheet metal screws and speed nuts provided.

Page 2: Install Guide for MOD2, NA Petroleum Canopy Power Supply it · Install Guide for MOD2, NA Petroleum Canopy Power Supply it 31 60107 75 W , 601075-088 88 W , 601075-105 105 W , 601075
Page 3: Install Guide for MOD2, NA Petroleum Canopy Power Supply it · Install Guide for MOD2, NA Petroleum Canopy Power Supply it 31 60107 75 W , 601075-088 88 W , 601075-105 105 W , 601075

Install Guide for MOD2, NA Petroleum Canopy Power Supply Kit

PN: 601074 (75 W), 601075-088 (88 W), 601075-105 (105 W), 601075 (150 W), with MODUS fixture. 601076 (200 W) with MODUS HO (High Output) fixture.

PAGE 3 OF 3

Customer service and technical support888.747.4LED (888.747.4533)SloanLED.com • [email protected]

Europe: Customer service and technical support+31 88 12 44 900 SloanLED.com • [email protected]

P/N 402067 Rev E 2019-06-28

US patents and foreign patents pending

Luminaire does not light after complete installation. Check connection from power supply lead to luminaire. Verify all pins in connectors are properly seated. Still does not light. Disconnect luminaire from power supply. Check output voltage of power supply using a voltmeter. The output voltage should be within ± 3 V of the voltage

shown in the table above. If there is no output voltage, have a licensed electrician check input voltage. Make sure power supply is connected correctly and getting primary power. If power supply is connected properly and getting primary power and there is still no output voltage, replace power supply.

Still does not light. If power supply is getting primary power, has the correct output, and luminaire does not light, there may be a short in the secondary wiring. Check all connections and the condition of the wires. Measure luminaire input resistance across the red and black leads. This should be an open circuit on typical handheld multimeters.

Troubleshooting

*When using 410180 power supply, use of Jumper Select Control Module P/N 601063-200 or 410168 is required to maintain warranty consideration. When using 410168, customer must provide waterproof junction box. Consult factory for control voltage settings. Failure to obtain control voltage settings from factory voids warranty.

601075 Input Output

Power Module Setting Nominal input voltage Input currentPower output

limitOutput current

limitLuminaire per power supply

No Jumper = High power 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 125 W 2.3 A 1

#1 Jumper = Mid power** 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 105 W 2.0 A 1

#2 Jumper = Low power** 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 88 W 1.6 A 1

701932 and 410168* 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC User setting 125 W max User setting 2.3 A max 1

150 Watt power supply capacity chart for PDL3 MODUS (White connectors on power supply)

601074 Input Output

Power Module Setting Nominal input voltage Input currentPower output

limitOutput current

limitLuminaire per power supply

No Jumper = High power 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 66 W 1.3 A 1

#1 Jumper = Mid power 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 51 W 1.1 A 1

#2 Jumper = Low power 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 36 W 0.9 A 1

410181 and 410168* 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC User setting 65 W max User setting 1.3 A max 1

75 Watt power supply capacity chart for PDL3 MODUS (White connectors on power supply)PDL3 MODUS

**For 601075-088 and 601075-105, power output is fixed at 88 W and 105 W respectively, and is not jumper selectable.

601076 Input Output

Power Module Setting Nominal input voltage Input current Power output limit Output current limitLuminaire per power supply

No Jumper = High power 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 157 W 0.75 A 1

#1 Jumper = Mid power 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 133 W 0.65 A 1

#2 Jumper = Low power 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC 116 W 0.57 A 1

410180 and 410168* 90-307 VAC, 47-63 Hz 2.0 A at 110/220 VAC User setting 165 W max Consult factory 1

200 Watt power supply capacity chart for PDL3 MODUS High Output (Black connectors on power supplies)PDL3 MODUS HO (High Output)