Inspection Date: Prepared For: Prepared By...address, city, MN 11111 Inspection Date: Thursday...
Transcript of Inspection Date: Prepared For: Prepared By...address, city, MN 11111 Inspection Date: Thursday...
address, city, MN 11111
Inspection Date:Thursday February 20, 2020
Prepared For:Client .
Prepared By:Hindsight Inspection Services LLC.
223 East Owasso LaneShoreview, MN 55126
Report Number:2019-3
Inspector:Michael Heinze
License/Certification #:MN--NACHI19061501
Inspector Signature:
address, city, MN 11111 Page 2
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Report OverviewScope of Inspection
All components designated for inspection in the ASHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind. Please refer to the pre-inspection contract for a full explanation of the scope of the inspection.
Main Entrance FacesEast
State of OccupancyOccupied
Weather ConditionsSunny
Recent RainNone
Ground CoverDry
Approximate Age41 years old
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 3
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Report SummaryMajor Concerns
Upper roof was damp and had movement when stepped on near chimney. After further investigation in attic below it was discovered that daylight could be seen between chimney and flashing. Evidence of plywood rot in this area is apparent. Replacement of wood rot, correcting the flashing and adding cricket in front of the chimney would be solutions to resolve this issue. Recomend a roofing contractor evaluate this further.
Basement and garage windows are in poor condition and have fogged glass
In basement North and East walls have cracking and moisture intrusion. Some repairs have been made, but appear not to have resolved the issues. Ductwork below slab has standing water in it. Recommend further evaluation by a qualified contractor or licensed engineer. Steel bracing/ buttressing of wall, pouring/ patching, of wall locations, and installing a sump pump system around perimeter walls would be likely options for improvement.
Potential Safety HazardsGas range exhaust fan is vented directly into basement and has not yet been extended outside.
Water heater did not have a relief valve extension pipe and is located inside a garage space without a protection ballard and is mounted below 18" near a potential ignition source.
For inhanced safety recomend fire rated walls, doors, and ceiling be installed between lower garage and house if parking combustion vehicles in this space.
Recomend adding handrail to basement stairway.
Deferred Cost ItemsWater heater functioned properly, however it's age has exceeded the typical life expectancy for the average water heater, recomend budgeting for replacement.
Improvement ItemsRecomend adding spark arrestor cap to top of chimney.
Minor Concerns Recommend MaintenanceTrim was in need of normal painting maintenance in a handful of areas.
Recomend replacement of trim around basement windows.
Noticed east living room window did not stay hung upright when un-latched. Springs may need to be repaired or replaced on the right section looking towards the outside.
Recomend repairing weatherstripping on garage service door.
In upper main bathroom pop up drains in tub and sink areas would not hold water when closed. May need adjustment or
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 4
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Report SummaryMinor Concerns Recommend Maintenance
gaskets replaced.
In master bathroom sink strainer is missing rod clip, this will need to be installed/ adjusted in order to operate strainer from faucet.
Receptacle on west wall in basement has open ground connection.
Some roof vents on upper roof show signs of rust. Recomend repainting or replacing.
Additional ReferencesAttached with this report are the following illustrations which describe specific items mentioned in this report: Typical water heater installation requirements for a garage, fire separation requirements, and common foundation problems and repairs.
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 5
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Receipt/InvoiceHindsight Inspection Services LLC.223 East Owasso LaneShoreview, MN 55126651-236-9906
Property Addressaddresscity, MN 11111
Date: Feb 20, 2020 Inspection Number: 2019-3
Inspected By: Michael Heinze Payment Method: Not Paid
Client: Client .
Inspection FeeHome Inspection $0.00
Total $0.00
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 6
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
GroundsService Walks
Material X ConcreteCondition X MarginalPhotos
Rear service walk has some cracking
Driveway/Parking
Material X ConcreteCondition X SatisfactoryStoops/Steps
Material X Wood Other: CompositeCondition X SatisfactoryDeck/Balcony
Material X CompositeCondition X SatisfactoryFinish X Not ApplicablePhotos
Rear deck Front deck
Fence/Wall
Type X BrickCondition X Satisfactory
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 7
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
GroundsFence/Wall cont.
Gate X N/AComments For inhanced safety railings could be installed in this location
Photos
Landscaping affecting foundation
Negative Grade X Satisfactory X Trim back trees/shrubberiesComments Recommend trimming trees/vegetation so it doesn not come into contact with the home
Hose bibs
Condition X SatisfactoryOperable X YesPhotos
Typical hose bibb
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 8
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
RoofGeneral
Visibility X AllInspected From X RoofStyle of Roof
Type X GablePitch X MediumRoof #1 - Lower Roof Type:Asphalt
Layers:1 Layer
Age:15-20+
Location:Garage
Roof #2 - Upper Roof Type:Asphalt
Layers:1 Layer
Age:15-20+
Location:House
Ventilation System
Type X Soffit X RoofComments Some roof vents on upper roof show signs of rust. Recomend repainting or replacing.
Photos
Roof Vents
Flashing
Material X Galv/AlumCondition X Poor X Separated from chimney/roofComments Roofing was damp and had movement when stepped on near chimney. After further investigation in attic it
was discovered that daylight could be seen between chimney and flashing. Evidence of plywood rot in this area is apparent. Replacement of wood rot, correcting the flashing and adding cricket in front of the chimney would be solutions to resolve this issue. Recomend a roofing contractor evaluate this further.
Photos
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 9
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Roof
Gap between flashing and chimney
Location of wood rot below Daylight seen below and rot
Cricket installation to divert water around chimney
Condition of Roof Coverings
Roof #1 - Lower Roof X Marginal X Cracking X Granules missing X Recommend roofer evaluateRoof #2 - Upper Roof X N/A X Poor X Cracking X Granules missing X Recommend roofer evaluatePhotos
Lower roof Upper roof
Skylights
Condition X SatisfactoryPhotos
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 10
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Roof
Skylight
Plumbing Vents
Condition X Satisfactory
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 11
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
ExteriorChimney(s)
Location(s) Upper roof
Viewed From X RoofRain Cap/Spark Arrestor X No X RecommendedChase X BlocksEvidence of X No apparent defectsFlue X TileEvidence of X Recommend Cricket/Saddle/FlashingCondition X MarginalComments Recomend adding spark arrestor cap to top of c himney . See roofing section for other recommended
flashing and roof repairs.
Photos
Spark arrestor rain cap
Siding
Material X StuccoCondition X SatisfactoryTrim
Material X Wood X Vinyl X StuccoCondition X MarginalComments Trim was in need of normal painting maintenance in a handful of areas. Recomend replacement of trim
around basement windows.
Photos
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 12
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Exterior
Trim damaged above basement window
Painting maintenance
Soffit
Material X Aluminum/SteelCondition X SatisfactoryFascia
Material X Aluminum/SteelCondition X SatisfactoryFlashing
Material X Aluminum/SteelCondition X SatisfactoryCaulking
Condition X MarginalX Recommend around windows/doors/masonry ledges/corners/utility penetrations
Windows/Screens
Condition X Satisfactory X Poor X Failed/fogged insulated glassMaterial X Metal X Aluminum/Vinyl cladScreens X SatisfactoryComments Basement and garage windows are in poor condition and have fogged glass all other windows are in
satisfactory condition. Noticed east living room window did not stay hung upright when un-latched. Springs may need to be repaired or replaced on the right section looking towards the outside. Dinning room windows were not opened, hardware is loose and may need ajustment.
Photos
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 13
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Exterior
Basement windows from inside Basement windows fogged glass Garage & basement windows fogged glass
Service Entry
Location X UndergroundCondition X SatisfactoryExterior receptacles X Yes Operable: X Yes No Condition: X Satisfactory Marginal PoorGFCI present X Yes Operable: X Yes NoComments All exterior and garage recepticles are controlled by a GFCI breaker in the main electrical panel.
Building(s) Exterior Wall Construction
Type X Framed X MasonryCondition X Satisfactory X PoorComments Wood framed walls not visible but appear satisfactory. Apparent movement and moisture in block foundation
walls. See basement section for further details.
Exterior Doors
Main Entrance Weatherstripping: X Satisfactory Marginal Poor Missing ReplaceDoor condition: X Satisfactory Marginal Poor
Sliding Doors To Deck Weatherstripping: X Satisfactory Marginal Poor Missing ReplaceDoor condition: X Satisfactory Marginal Poor
Rear Basement Garage Door Weatherstripping: Satisfactory X Marginal Poor MissingReplace Door condition: X Satisfactory Marginal Poor
Garage Service Door Weatherstripping: Satisfactory Marginal X Poor Missing X ReplaceDoor condition: Satisfactory X Marginal Poor
Comments Recomend repairing weatherstripping on garage service door.
Photos
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 14
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Exterior
Garage Service Door - Weatherstripping in need of repair
Exterior A/C - Heat pump #1
Unit #1 Location:West side of house
Brand:Bryant Heating and Cooling Systems
Model #: 265ANA030
Serial #: 3508E21523Approximate Age: 11 Years
Condition X SatisfactoryEnergy source X ElectricUnit type X Heat pumpOutside Disconnect X Yes Maximum fuse/breaker rating (amps): 30
Fuses/Breakers installed (amps): 30Level X YesCondenser Fins X SatisfactoryInsulation X YesImproper Clearance (air flow) X NoPhotos
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 15
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Garage/CarportType
Type X Attached X 2-CarPhotos
Main garage Lower garage
Automatic Opener
Operation X OperableSafety Reverse
Operation X Operable X Photo eyes and pressure reverse testedFloor
Material X Concrete Other: SpancreteCondition X SatisfactorySource of Ignition within 18" of the floor X Yes X NoComments Water heater located in lower garage space. This is a potential source of ignition. See water heater section
for recommended requirements.
Overhead Door(s)
Material X MetalCondition X SatisfactoryRecommend Priming/Painting Inside & Edges X NoElectrical Receptacles
Reverse polarity X NoOpen ground X NoGFCI Present X Yes Operable: X Yes NoFire Separation Walls & Ceiling
X PresentCondition X Satisfactory X Safety hazard(s)Moisture Stains Present X NoTypical Cracks X NoFire door X SatisfactorySelf closure X Missing
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 16
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Garage/CarportFire Separation Walls & Ceiling cont.
Comments Main garage is satisfactory. Lower garage in basement does not have a fire separation between the unfished basement and the family room floor above.
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 17
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
KitchenCountertops
Condition X SatisfactoryPhotos
Kitchen
Cabinets
Condition X SatisfactoryPlumbing
Faucet Leaks X NoPipes leak/corroded X NoSink/Faucet X SatisfactoryFunctional drainage X SatisfactoryFunctional flow X SatisfactoryWalls & Ceiling
Condition X Marginal X Moisture stainsComments Moisture stains were tested with moisture meter and apear inactive, stains are believed to be caused from
old shower above that has sense been replaced.
Heating/Cooling Source
X YesFloor
Condition X SatisfactoryAppliances
Disposal Operable: X Yes NoOven Operable: X Yes NoRange Operable: X Yes NoDishwasher X Not tested Operable: X Yes NoExhaust fan Operable: X Yes NoRefrigerator Operable: X Yes NoMicrowave Operable: X Yes NoDishwasher airgap X Yes
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 18
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
KitchenAppliances cont.
Dishwasher drain line looped X YesReceptacles present X Yes Operable: X Yes NoGFCI X Yes Operable: X Yes NoOpen ground/Reverse polarity: X NoComments Gas range exhaust fan is vented directly into basement and has not yet been extended outside. This is a
potential safety hazard.
Photos
Range exhaust Range exhaust terminates in basement
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 19
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Laundry RoomLaundry
Laundry sink X N/AFaucet leaks X NoPipes leak X YesCross connections X YesHeat source present X YesRoom vented X YesDryer vented X WallElectrical Open ground/reverse polarity: Yes X NoGFCI present X Yes Operable: X Yes NoAppliances X Washer X DryerWasher hook-up lines/valves X SatisfactoryGas shut-off valve X N/AComments Discovered moisture in ceiling which is being contributed by the flashing roofing issues above next to the
chimney. See further details in roofing section.
Photos
Moister above ceiling Laundry room
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 20
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Bathroom (1)Bath
Location Main floor
Sinks Faucet leaks: Yes X No Pipes leak: Yes X NoToilet Bowl loose: Yes X No Operable: X Yes NoDrainage X SatisfactoryWater flow X SatisfactoryMoisture stains present X NoDoors X SatisfactoryWindow X SatisfactoryReceptacles present X Yes Operable: X Yes NoGFCI X Yes Operable: X Yes NoOpen ground/Reverse polarity X NoHeat source present X YesExhaust fan X Yes Operable: X Yes NoPhotos
Main floor Bathroom
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 21
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Bathroom (2)Bath
Location Upper floor
Sinks Faucet leaks: Yes X No Pipes leak: Yes X NoTubs Faucet leaks: Yes X No Pipes leak: Yes X No Not VisibleShowers Faucet leaks: Yes X No Pipes leak: Yes No X Not VisibleToilet Bowl loose: Yes X No Operable: X Yes NoShower/Tub area X Ceramic/Plastic Condition: X Satisfactory Marginal Poor Rotted floors
Caulk/Grouting needed: Yes X NoDrainage X SatisfactoryWater flow X SatisfactoryMoisture stains present X NoDoors X SatisfactoryWindow X SatisfactoryReceptacles present X Yes Operable: X Yes NoGFCI X Yes Operable: X Yes NoOpen ground/Reverse polarity X NoHeat source present X YesExhaust fan X Yes Operable: X Yes NoComments Pop up drains in tub and sink areas would not hold water when closed. May need adjustment or gaskets
replaced
Photos
Pop up drain
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 22
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Bathroom (3)Bath
Location Upper floor Master Bathroom
Sinks Faucet leaks: Yes X No Pipes leak: Yes X NoTubs Faucet leaks: Yes X No Pipes leak: Yes X No Not VisibleShowers Faucet leaks: Yes X No Pipes leak: Yes No X Not VisibleToilet Bowl loose: Yes X No Operable: X Yes NoShower/Tub area X Masonite Other: Tile Condition: X Satisfactory Marginal Poor
Rotted floorsDrainage X SatisfactoryWater flow X SatisfactoryMoisture stains present X NoDoors X SatisfactoryWindow X SatisfactoryReceptacles present X Yes Operable: X Yes NoGFCI X Yes Operable: X Yes NoOpen ground/Reverse polarity X NoHeat source present X YesExhaust fan X YesComments Sink strainer is missing rod clip, this will need to be installed/ adjusted in order to operate strainer from
faucet.
Photos
Master Bathroom Strainer rod needs adjustment and clip
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 23
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Room (1)Room
Location Upper floor North West
Type Master Bedroom
Walls & Ceiling X SatisfactoryMoisture stains X NoFloor X MarginalCeiling fan X NoneElectrical Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesBedroom Egress restricted X NoDoors X SatisfactoryWindows X SatisfactoryPhotos
Master Bedroom
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 24
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Room (2)Room
Location Upper floor North East
Type Bedroom
Walls & Ceiling X SatisfactoryMoisture stains X NoFloor X MarginalCeiling fan X NoneElectrical Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesBedroom Egress restricted X NoDoors X SatisfactoryWindows X SatisfactoryPhotos
North East Bedroom
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 25
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Room (3)Room
Location Upper floor South East
Type Bedroom
Walls & Ceiling X SatisfactoryMoisture stains X NoFloor X SatisfactoryCeiling fan X NoneElectrical Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesBedroom Egress restricted X NoDoors X SatisfactoryWindows X SatisfactoryPhotos
South East Bedroom
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 26
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
InteriorFireplace
Location(s) Main Floor and Basement
Type X WoodMaterial X MasonryMiscellaneous Operable: Yes X No Damper operable: X Yes NoDamper modified for gas operation X N/AHearth extension adequate X YesMantel X N/APhysical condition X SatisfactoryComments Note lower fire place has never been used. Fire place doors should be installed for lower fireplace to
function safely.
Photos
Fireplace family room side Fireplace kitchen side
Stairs/Steps/Balconies
Condition X SatisfactoryHandrail X Safety hazard X Hand Rail/Railing/Balusters recommendedRisers/Treads X SatisfactoryComments For inhanced safety recomend installing handrail on basement stairway
Photos
Basement Stairway Missing Handrail
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 27
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
InteriorSmoke/Carbon Monoxide detectors
Smoke Detector X Present Operable: Yes No X Not tested Recommend additionalCO Detector X Present Operable: Yes No X Not tested Recommend additionalAttic/Structure/Framing/Insulation
Access X Scuttlehole/HatchInspected from X Access panel X In the atticLocation X Hallway X GarageFlooring X NoneInsulation X Batts Depth: 12" above house atticInstalled in X Rafters/TrussesVapor barriers X Kraft/foil faced X Not VisibleVentilation X Ventilation appears adequateFans exhausted to Attic: Yes X No Recommend repair Outside: X Yes NoHVAC Duct X SatisfactoryChimney chase X SatisfactoryStructural problems observed X NoRoof structure X Rafters X WoodCeiling joists X WoodSheathing X Plywood X Rotted X StainedEvidence of condensation X NoEvidence of moisture X YesEvidence of leaking X YesFirewall between units X YesElectrical X No apparent defectsComments Attic above upper floor has leak and moisture intrusion at Chimney penetration through roof. See roofing
section for further details. Lower attic above garage was in satisfactory condition.
Photos
Lower attic above garage Upper attic above upper floor
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 28
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
BasementFoundation
Condition X Have evaluated X MonitorMaterial X Concrete blockHorizontal cracks X North X EastStep cracks X NorthVertical cracks X NoneCovered walls X WestMovement apparent X North X EastIndication of moisture X Yes X FreshComments North and East walls have cracking and moisture intrusion. Some repairs have been made, but appear not
to have resolved the issues. Recommend further evaluation by a qualified contractor or licensed engineer. Steel bracing/ buttressing of wall, pouring/ patching, of wall locations, and installing a sump pump system around perimeter walls would be likely options for lmprovement.
Photos
North Wall step cracking and horizontal cracking
East wall horizontal cracking
Floor
Material X ConcreteCondition X Satisfactory X Typical cracksGirders/Beams
Condition X SatisfactoryMaterial X SteelColumns
Condition X SatisfactoryMaterial X SteelJoists
Condition X SatisfactoryMaterial X Wood X 2x10Subfloor
Condition X Satisfactory
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 29
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
PlumbingWater service
Main shut-off location Basement North wall
Water entry piping X Copper/Galv.Lead other than solder joints X UnknownVisible water distribution piping X CopperCondition X SatisfactoryFlow X SatisfactoryPipes Supply/Drain Cross connection: Yes X No Safety Hazard X SatisfactoryDrain/Waste/Vent pipe X PVC X ABSCondition X SatisfactorySupport/Insulation X N/ATraps proper P-Type X YesDrainage X SatisfactoryFuel line X Copper X Black ironCondition X SatisfactoryPhotos
Water Meter and Main Shutoff Valve
Main fuel shut-off location
Location Basement Near Furnace
Water heater #1
General Brand Name: AO Smith Model: KGA 40 860
Serial #: 86C-A-79-66651Capacity:40 Gallon
Approx. age: 33 years old
Type X GasCombustion air venting present X YesSeismic restraints needed X N/ARelief valve X Yes Extension proper: Yes No X Missing X Recommend repair
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 30
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Plumbing
Water heater #1 cont.
Relief valve X Yes Extension proper: Yes No X Missing X Recommend repairVent pipe X SatisfactoryCondition X MarginalComments Water heater functioned properly, however it's age has exceeded the typical life expectancy for the average
water heater, recomend budgeting for replacement. Tank drain valve on water heater has a slow drip. Water heater did not have a relief valve extension pipe and is located inside a garage space without a protection ballard and is mounted below 18" near a potential ignition source: Four wheelers, gas cans etc. These are potential safety hazards. See typical water heater installation for a garage space.
Photos
Drain valve drips, water heater is in garage space needs to be elevated 18" and have protective ballards
Missing Relief Valve Extension Typical water heater installation
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 31
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Heating SystemHeating system
Unit #1 Brand name: Bryant
Approx. age: 11 Years
Model #: 355CAV0Y0100FASA Serial #: 2208A01449 X SatisfactoryEnergy source X GasWarm air system X Direct driveHeat exchanger X Sealed X Not VisibleCombustion air venting present X YesControls Disconnect: X Yes No X Normal operating and safety controls observed
Gas shut off valve: X Yes NoDistribution X Metal duct X Cold air returnsFlue piping X SatisfactoryFilter X Standard X SatisfactoryWhen turned on by thermostat X Fired Proper operation: X Yes No Not testedHeat pump X Supplemental gasSub-slab ducts X Poor Water/Sand Observed: X Yes NoSystem not operated due to X N/AComments Existing furnace filter was dirty, replaced with new furnace filter while onsite. (Filter size 20 x 24 x 4) Inside
of furnace was clean, draft fan operation was satisfactory, condensate drain was inspected and showed no signs of leaks. Furnace was operated in cooling mode only. Heating mode was not tested. Heating mode runs the refrigeration loop in reverse utilizing the heat pump for supplemental heating, the natural gas heat exchanger will turn on when the heat pump can not keep up.
Photos
Inside Furnace 20 x 24 x 4 Filter replaced 5/7/19 Ductwork below slab has water in it
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 32
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Electric/Cooling SystemMain panel
Location Basement South Wall
Condition X SatisfactoryAdequate Clearance to Panel X YesAmperage/Voltage X 200aBreakers/Fuses X BreakersAppears grounded X YesGFCI breaker X Yes Operable: X Yes NoAFCI breaker X NoMain wire X Aluminum Condition: X Satisfactory Marginal PoorBranch wire X CopperBranch wire condition X SatisfactoryComments Receptacle on west wall in basement has open ground connection. Recomend qualified electrical contractor
inspect/ reconnect ground wire behind receptacle.
Photos
Main electrical panel Open ground to receptacle west basement wall
Evaporator Coil Section Unit #1
General X Central systemLocation:Basement
Age:11 years
Evaporator coil X Not VisibleRefrigerant lines X SatisfactoryCondensate line/drain X Floor drainCondition X Satisfactory
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 33
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Living RoomLiving Room
Location Main floor South of kitchen
Walls & Ceiling X Satisfactory X Typical cracksMoisture stains X Yes
Where:South of chimney
Floor X SatisfactoryCeiling fan X NoneElectrical Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesDoors X SatisfactoryWindows X SatisfactoryComments Moisture stains on ceiling were tested with moisture meter and have some active moisture. Likely cause is
from leak on upper roof near chimney. See roofing section for further details
Photos
Living room
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
address, city, MN 11111 Page 34
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.
Dining RoomDining Room
Location Main floor north of kitchen
Walls & Ceiling X SatisfactoryMoisture stains X NoFloor X SatisfactoryCeiling fan X NoneElectrical Switches: X Yes No X Operable Receptacles: X Yes No X Operable
Open ground/Reverse polarity: Yes X NoHeating source present X YesDoors X NoneWindows X Marginal X Broken/Missing hardwareComments See window section for additional comments regarding windows in the room.
Photos
Dinning room Dinning room
This confidential report is prepared exclusively for Client .©2020 Hindsight Inspection Services LLC.