INSITE Fault Viewer Training
-
5/25/2018 INSITE Fault Viewer Training
2/21
INSITE Fault Viewer TrainingAgenda
INSITE Fault Viewer Overview
Using the Tool
Features and Benefits
Applications
Specifications
System Diagram
Support
Frequently Asked Questions
Summary
-
5/25/2018 INSITE Fault Viewer Training
3/21
INSITE Fault Viewer Overview
INSITE Fault Viewer is designed to
provide the ability to monitor public faults on
a J1939 or J1708 network
INSITE Fault Viewer will help to isolate the
probable cause of a system failure or error
This information can be used to troubleshoot
Cummins Inc. engine problems as well asother devices on the network
Back to Agenda
-
5/25/2018 INSITE Fault Viewer Training
4/21
Using the Tool
To open INSITE Fault Viewer, go toStart >All Programs >Cummins Inc >INSITE
Fault Viewer
INSITE Fault Viewer will try to
automatically connect when it is started
If the appropriate datalink adapter is not
connected, an error will display
INSITE and INSITE Fault Viewercannotbe connected at the same time,
since both use the same datalink adapter
connection
Back to Agenda
-
5/25/2018 INSITE Fault Viewer Training
5/21
Fault Viewer will
try to auto
connect when it
starts
-
5/25/2018 INSITE Fault Viewer Training
6/21
Refresh fault
information
Save fault
information
being
displayed
Print fault
information
being
displayed
Available
datalink
adapter
vendors
Available
datalink
adapters for
selected
vendor
-
5/25/2018 INSITE Fault Viewer Training
7/21
Displays all fault
information
from devices on
J1939 network
Displays all fault
information
from devices on
J1708 network
Available help
information
INSITE Fault
Viewer Training
Presentation
INSITE Fault
Viewer Status
Datalink adapter
name, firmware
version
-
5/25/2018 INSITE Fault Viewer Training
8/21
Click on J1939 or J1708
tab to look at the fault
codes for J1939 or
J1708 respectively
-
5/25/2018 INSITE Fault Viewer Training
9/21
INSITE Fault Viewer
Indicators
-
5/25/2018 INSITE Fault Viewer Training
10/21
Last successful
faults retrieval
time
Reset Fault
Codes for
device
shown
Reset all
inactive faults
on J1939 or
J1708 network
-
5/25/2018 INSITE Fault Viewer Training
11/21
Displaying Four Devices on
J1939 Network with no Active
or Inactive Fault Codes
-
5/25/2018 INSITE Fault Viewer Training
12/21
Device information is displayed in thefollowing format in INSITE Fault Viewer:
0: Engine #1, CMMNS, 6M3u07D110000, 0000
18 Faults 18 Active
Source Address
and device name Manufacturer Model
Serial
number
Fault Summary: Total
number of faults andnumber of active faults
-
5/25/2018 INSITE Fault Viewer Training
13/21
110: Engine Coolant Temperature
1 31: Condition Exits
Failure Mode
Identifier (FMI)
FMI
Description
Fault Count:
Number of times
the fault
occurred
Fault Source- Suspect Parameter Number
(SPN) for J1939 or Source-Parameter
Identifier (PID) or Subsystem Identifier (SID)Fault Code (SPN)
Description
Fault information is displayed in the
following format on the J1939 or J1708
network:
-
5/25/2018 INSITE Fault Viewer Training
14/21
Features and Benefits of INSITEFault Viewer
Main Features include:
Reading Fault Data from all the devices
connected to J1939 / J1708 network Resetting Inactive Faults
Saving Fault Data
Printing Fault Data
Back to Agenda
-
5/25/2018 INSITE Fault Viewer Training
15/21
Main Benefits are:
Fast
Simple to use
Visible at a distance
Saving and printing fault data
Features and Benefits of
INSITE Fault Viewer
-
5/25/2018 INSITE Fault Viewer Training
16/21
Applications
Quick view of all faults on the system
Not limited to engine faults
Quick view of all devices on the system
Useful for Service Technicians, Service
Engineers, Distributor Field Service
Engineers, Performance Engineers,Application Engineers and Control System
Developers
Back to Agenda
-
5/25/2018 INSITE Fault Viewer Training
17/21
Specifications
Requires All of the Following:
Any active INSITE version except INSITE
Basic
INSITE used within the last 90 days Microsoft .Net 4.0, or higher, framework
RP1210a compliant datalink adapter (DLA)
Back to Agenda
-
5/25/2018 INSITE Fault Viewer Training
18/21
System Diagram
Back to Agenda
-
5/25/2018 INSITE Fault Viewer Training
19/21
Support
Technical support provided using existingINSITE Help Desk process
For assistance call:
1-800-433-9341 or 1-812-377-8136and selectoption 2
Back to Agenda
-
5/25/2018 INSITE Fault Viewer Training
20/21
Frequently Asked Questions
Do I need to run INSITE to start and runINSITE Fault Viewer?
No
INSITE Fault Viewer is independent of INSITE You can use INSITE Fault Viewer without using
INSITE, but you must have a active registeredversion of INSITE (except for INSITE Basic)installed on the PC
Who should I contact if I have any probleminstalling or using INSITE Fault Viewer?upport
-
5/25/2018 INSITE Fault Viewer Training
21/21
Summary
INSITE Fault Viewer is an INSITE Add-
on
It provides a list of devices attached to the
J1939 or J1708 network along with anyfaults reported by each device
Back to Agenda