Input & Output Processor - accessnsite.com · The Input Processor (IP) provides the capability of...

2
The Input Processor (IP) provides the capability of supporting 16 general purpose inputs such as motion detectors, door contacts, or panic alarms. It also has two general purpose outputs. The Output Processor (OP) provides the capability of supporting 16 general purpose outputs. The outputs can be used for a variety of purposes such as lighting, heating/cooling, and door and elevator control. Inputs can be individually set to be normally-open or normally- closed, can be configured as either supervised or unsupervised, and can be masked. Each input can also be set for sensitivity ranges, timing parameters, and end-of-line resistance values. Outputs are Form-C (NO/NC) relays and can be configured for fail-safe or fail-secure operation. Relays support “On”, “Off”, “Pulse” and “Repeat Pulse” commands. Relay operation and alarm masking may be initiated by operator action, time schedule, or triggered by an event. The IP and OP use a high speed, two wire, multi-drop RS-485 interface to communicate with the controller (ADC, IDC, or IDC-1). Events generated by the IP or OP can be used to trigger actions locally or on other sub-controllers attached to the same controller. Status change, command, and configuration information is ex- changed with the controller. The controller is managed by a host computer using industry leading AccessNsite® software, but runs independently when not communicating with the host. Quintron Systems, Inc. Security Systems Division 2105 S. Blosser Road Santa Maria, California 93458 Phone: (805) 928–4343 Fax: (805) 928–9914 Web: www.quintron.com Email: sales @ quintron.com Control up to 16 points with one board • Most widely accepted access control hardware due to its reliability and open architecture • AES 128 bit data encryption • Compatible across Quintron’s family of Distributed Controllers • Dedicated tamper and power fault monitoring • 12v to 24v DC operation • Configurable input/output parameters • Diagnostic LEDs • Field upgradable firmware • UL listed 294/1076 • 1-year limited warranty Input & Output Processor powered by ® Features Output Processor (16 outputs) Input Processor (16 inputs)

Transcript of Input & Output Processor - accessnsite.com · The Input Processor (IP) provides the capability of...

Page 1: Input & Output Processor - accessnsite.com · The Input Processor (IP) provides the capability of supporting 16 general purpose inputs such as motion detectors, door contacts, or

The Input Processor (IP) provides the capability of supporting 16 general purpose inputs such as motion detectors, door contacts, or panic alarms. It also has two general purpose outputs. The Output Processor (OP) provides the capability of supporting 16 general purpose outputs. The outputs can be used for a variety of purposes such as lighting, heating/cooling, and door and elevator control.

Inputs can be individually set to be normally-open or normally- closed, can be configured as either supervised or unsupervised, and can be masked. Each input can also be set for sensitivity ranges, timing parameters, and end-of-line resistance values. Outputs are Form-C (NO/NC) relays and can be configured for fail-safe or fail-secure operation. Relays support “On”, “Off”,

“Pulse” and “Repeat Pulse” commands. Relay operation and alarm masking may be initiated by operator action, time schedule, or triggered by an event. The IP and OP use a high speed, two wire, multi-drop RS-485 interface to communicate with the controller (ADC, IDC, or IDC-1).

Events generated by the IP or OP can be used to trigger actions locally or on other sub-controllers attached to the same controller. Status change, command, and configuration information is ex- changed with the controller. The controller is managed by a host computer using industry leading AccessNsite® software, but runs independently when not communicating with the host.

Quintron Systems, Inc.Security Systems Division

2105 S. Blosser RoadSanta Maria, California 93458

Phone: (805) 928–4343Fax: (805) 928–9914

Web: www.quintron.comEmail: [email protected]

Control up to 16 points with one board

• Most widely accepted access control hardware due to its reliability and open architecture• AES 128 bit data encryption

• Compatible across Quintron’s family of Distributed Controllers• Dedicated tamper and power

fault monitoring

• 12v to 24v DC operation• Configurable input/output parameters• Diagnostic LEDs• Field upgradable firmware

• UL listed 294/1076 • 1-year limited warranty

Input & Output Processor

powered by

®

Features

Output Processor(16 outputs)Input Processor

(16 inputs)

Page 2: Input & Output Processor - accessnsite.com · The Input Processor (IP) provides the capability of supporting 16 general purpose inputs such as motion detectors, door contacts, or

Quintron Systems, Inc.Security Systems Division

2105 S. Blosser RoadSanta Maria, California 93458

Phone: (805) 928–4343Fax: (805) 928–9914

Web: www.quintron.comEmail: [email protected]

Primary Power• 12 to 24Vdc +/- 10%, 350 mA max

Relays• 2 Relays: Form-C, 5A @ 28 Vdc

Inputs• 16 supervised • 2 dedicated: Tamper & power fault

Primary Power• 12 to 24Vdc +/- 10%, 1100

mA max

Relays• 16 Relays: Form-C, 5A @ 28 Vdc

Inputs• 2 dedicated: Tamper &

power fault

Dimensions• 6.0” W x 8.0” L x 1.0” H

Temperature• 0°C to +70°C operating • -55°C to +85°C storage

Humidity• 0 to 95% RHNC

Communication• RS-485, 2-wire, 4000’

Certifications• UL294, UL1076 • CE • RoHS

QuintronCustom Enclosures

* For a list of preconfigured enclosures, see Quintron’s Enclosures brochure.

IP Specifications OP Specifications Common Specifications

ERI

MUX8

Controller

Network

OutputProcessor

InputProcessor

SRI

DRI

powered by

®

KRIInput Processor

STATU

S LE

Ds

J3

SG

R-

R+

TR-

TR+

AC

DC

AC

GN

D IN1IN2IN3IN4IN5IN6IN7IN8

2W 4W

RS 485

GN

D

CT

BA

OFF O

N

8 7 6 5 4 3 2 1

J1

RS

-485

GN

D

IN11IN12IN13IN14IN15IN16NO C NC NO C NC

OU

T1

OU

T2

ABK1

K2 IN9IN10

12345678

910111213141516

J2

TER

M

CT

BA 5.50 [139.70]

6.00 [152.40]

2.00 [50.80] 2.00 [50.80]3.00 [76.20]

8.00 [203.20]

Output Processor

J3

SG

R-

R+

TR-

TR+

AC

DC

AC

GN

D

2W 4W

RS 485

OFF O

N

8 7 6 5 4 3 2 1

J1

RS

-485

ABCT

BA

J2

TER

M

STATU

S LE

Ds

1 2 3 4 5 6 7 8 9 10 11121314 15 16N

CCC

OM

NC

CCO

M

NC

CCO

M

NC

CCO

M

NC

CCO

M

NC

CCO

M

NC

CCO

M

NC

CCO

M

NCC

CO

M

NCC

CO

MNCC

CO

M

NCC

CO

MNCC

CO

M

NCC

CO

MNCC

CO

M

NCC

CO

MGN

D

BA

GN

D

CT

5.50 [139.70]6.00 [152.40]

2.00 [50.80] 2.00 [50.80]3.00 [76.20]

8.00 [203.20]

QuintronCustom Enclosures