Inline Chemical Heater Highest Temperature Process … · North America +1 800 621 1998...
Transcript of Inline Chemical Heater Highest Temperature Process … · North America +1 800 621 1998...
![Page 1: Inline Chemical Heater Highest Temperature Process … · North America +1 800 621 1998 International +1 440 974 1300 processtechnology.com PRODUCT DATA SHEET Rugged design provides](https://reader031.fdocuments.in/reader031/viewer/2022031002/5b83f14d7f8b9a23668e1e5c/html5/thumbnails/1.jpg)
North America +1 800 621 1998 ▪ International +1 440 974 1300 ▪ processtechnology.com
PRODUCT DATA SHEET
Rugged design provides long life in harsh, high-
temp. environments
Achieves the highest temperature heating,
up to 210°C
Long life & reduced cost of ownership with
patented purge
Clean operation with thick PTFE sheath & purge to minimize contamination
Low Watt density enables accurate control of process temperature
Up to 210°C
689 kPa @ 25°C296 kPa @ 180°C
TIHInline Chemical Heater
1 to 18 kW
CE, UL, Semi S2
200 to 600 Volts, single or three phase
Highest Temperature Process Fluid Heating Available!
![Page 2: Inline Chemical Heater Highest Temperature Process … · North America +1 800 621 1998 International +1 440 974 1300 processtechnology.com PRODUCT DATA SHEET Rugged design provides](https://reader031.fdocuments.in/reader031/viewer/2022031002/5b83f14d7f8b9a23668e1e5c/html5/thumbnails/2.jpg)
Features & Values Specifications ¾ All fluoropolymer wetted surfaces for virtually any wet
chemistry application.
¾ Rugged construction with thick walled chamber that provides long service life for the most demanding high-temp recirculation or single pass chemical applications
¾ Reduced cost of ownership, extended service life, & enhanced cleanliness with patented purge which removes chemical permeation & minimizes ionic contamination
¾ Fast heatup with single heater chamber sizes up to 18kW
¾ Rapid installation with custom plumbing connections available to match existing plumbing & case installation
¾ Precise & stable control of process temperature with low Watt density design
¾ PVDF high-temp. mounting brackets (High-temp. model)
¾ Horizontally mounted configuration (option)
¾ Capacitive style liquid level verification (option)
Wattages
TIH DATA SHEET
Temperature Range
1,000 to 18,000 Watts
CE, UL, Semi S2
Up to 210º C.
à 6 to 25mm flared à 12 to 25mm Super 300 Type Pillar® à Other connections available,
consult factory
Certifications
Fluid Connections
Model Number Breakdown
Dimensions
Voltages 200 to 600 Volts, single or 3-phase (12kW & larger require 3-phase)
Pressure Range 689 kPa @ 25°C296 kPa @ 180°C
Element Purge Small amount of clean dry air (CDA) or N₂ gas flows between the grounded element & PTFE sheath. Removes chemical permeation and minimizes ionic contamination for longer life
TIH 6 - 3 1 B A S R R
| | | | | | | | |
TIH series Wattage, kW - Voltage Phase Inlet and Outlet Connections Drain Connection Plumbing Configuration Process sensor type Overtemp sensor type
01 thru 18 1 = 208V 1 or 3 A = 1/2" Flared O (or 0) = No Drain S = Straight (180° opposed inlet, outlet, center-bottom drain) J = Type J thermocouple E = Type E thermocouple
2 = 240V B = 3/4" Flared A = 1/2" Flared R = Bottom side inlet, rotated 90° to right of outlet (center-bottom drain) K = Type K thermocouple K = Type K thermocouple
3 = 380V C = 1" Flared B = 3/4" Flared L = Bottom side inlet, rotated 90° to left of outlet (center-bottom drain) H = 100-Ohm RTD (2-wire) H = 100-Ohm RTD (2-wire)
4 = 400V S = 3/8" Flared S = 3/8" Flared E = Bottom side inlet, rotated 180° from outlet (center-bottom drain) R = 1000-Ohm RTD (2-wire) R = 1000-Ohm RTD (2-wire)
5 = 415V T = 3/8" Super 300 Pillar T = 3/8" Super 300 Pillar A = Bottom side inlet, directly below outlet (center-bottom drain) O = No process sensor
6 = 480V U = 25mm union V = 1/2" Super 300 Pillar B = Bottom inlet center of bottom, (standard no drain, side bottom drain if required)
7 = 440V V = 1/2" Super 300 Pillar W = 3/4" Super 300 Pillar C = Straight (side-drain, below inlet)
8 = 575V W = 3/4" Super 300 Pillar Y = 1/4" Super 300 Pillar D = Straight (side-drain, below outlet)
9 = 220V X = 1" Super 300 Pillar Z = 1/4" Flared H = Horizontal design (similar to B, but with drain on lower side, opposite outlet)
10 = 200V 4 = 20mm union 4 = 20mm union Other configurations = issue new plumbing deisgnation
14 = 600V
15 = 230V
16 = 450V
kW LENGTH mm(in)123
4.56 629(24.75)9
1213.518
508(20.00)
845(33.25)
1066(42.00)
HORIZONTALCONFIGURATION
kW LENGTH mm(in)123
4.569
1213.5 1022(40.25)18 1073(42.25)
870(34.25)
VERTICALCONFIGURATION
463(18.25)
667(26.25)
∅191mm(7.50in)
OVERALLLENGTH
DS05102018