Ingress Protection and Duty Cycle of MOTOR

download Ingress Protection and Duty Cycle of MOTOR

of 4

Transcript of Ingress Protection and Duty Cycle of MOTOR

  • 8/10/2019 Ingress Protection and Duty Cycle of MOTOR

    1/4

  • 8/10/2019 Ingress Protection and Duty Cycle of MOTOR

    2/4

    any direction shall have no harmful

    effects.

    minute

    Prepssure:30 kPa at distance of3m

    6 Power fulwater jets

    Water projected in powerful jets(12.5 mm nozzle) against the

    enclosure from any direction shallhave no harmful effects.

    Test duration: at least 3 minutesWater volume:100 litres per

    minutePrepssure: 100 kPa at a distance

    of 3 m

    7 Immersion up

    to 1 m

    Ingress of water in harmful quantity

    hall not be possible when theenclosure is immersed in water

    under defined condtions of pressureand time (up to 1 m of submersion).

    Test duration: 30 minutes

    Immersion at depth of at lest 1 mmeasured at bottom of device,

    and at least 15 cm measured attop of device

    8 Immersionbeyond 1 m

    The equipment is suitable forcontinuous immersion in water

    under conditions which shall be

    specified by the manufacturer.Normally, this will mean that thequipment is hermetically sealed.

    However, with certain types ofequipment, it can mean that water

    can enter byt onloy in such amanner that it produces no harmful

    effects.

    Test duration: continuousimmersion in water

    Depth specified by manufacturer

  • 8/10/2019 Ingress Protection and Duty Cycle of MOTOR

    3/4

    Duty cycle of motor:

    IEC (the International Electrotechnical Commission) uses eight duty cycle designations to

    describe an electrical motors operating conditions:

    S1 Continuous duty The motor works at a constant load for enough time to reachtemperature equilibrium

    S2 Short time duty The motor works at a constant load, but not lond enough toreach temperature equilibrium. The rest periods are long

    enough for the motor to reach ambient temperature

    S3 Intermittent periodic

    duty

    Sequential, identical run and rest cycles with constant load.

    Temperature equilibrium is never reached. Stating current haslittle effect on temperature rise.

    S4 Intermittent periodic

    duty with stating

    Sequential, identical start, run and rest cyckles with constant

    load. Temperature equilibrium is not reached, but startingcurrent affects temperature rise.

    S5 Intermittent periodicduty with electric

    braking

    Sequential, identical cycles of starting, running at constant loadand running with no load. No rest periods.

    S6 Continuous operation

    with intemittent load

    Sequential, identical cycles of running with constant load and

    running with no load. No rest periods.

    S7 continuous operation

    with electric braking

    Sequential identical cycles of starting, running at constant load

    and electric braking. No rest periods

    S8 Continuous operation

    with periodic changes inload and speed

    Sequential, identical duty cycles run at constant load and given

    speed, then run at other constant loads and speeds. No restperiods.

  • 8/10/2019 Ingress Protection and Duty Cycle of MOTOR

    4/4

    Cooling methods of motor: (IC Index of cooling )