InfraStruXure Integrated Solutions
We’re waiting for your call or email. 800-222-1440 [email protected]
Typical Configurations> WIRING CLOSETS [ 1-3 RACKS ] 4
> COMPUTER ROOMS [ 1-5 RACKS ] 5
> SMALL DATA CENTERS [ 5-20 RACKS ] 6
> MEDIUM DATA CENTERS [ 20-100 RACKS ] 7
> LARGE DATA CENTERS [ >100 RACKS ] 8
Components
> POWER 10
> COOLING 12
> RACK 14
> MANAGEMENT 16
> SERVICES 18
5 Easy Steps to Build Your InfraStruXure™
InfraStruXure™ Customer Testimonials
20
Introduction> KEY CONSIDERATIONS OF NCPI 2
> BRAYTON INTERNATIONAL 4
> FIRST RELIANCE BANK 5
> BOSTON MEDICAL CENTER HEALTHNET PLAN 6
> TIME WARNER CABLE 7
> ACIS 19
> CARLYLE, INC. 20
WIRING CLOSET [ 1-3 RACKS ]
COMPUTER ROOMS[ 1-5 RACKS ]
SMALL DATA CENTERS[ 5-20 RACKS ]
MEDIUM DATA CENTERS [ 20-100 RACKS ]
LARGE DATA CENTERS [ >100 RACKS ]
Typical Configurations
–Frank Lloyd WrightAmerican Architect, 1867-1959
Architecture is thescientific art ofmaking structureexpress ideas.
“
Is InfraStruXure right for your IT environment?
InfraStruXure’s modular architecture can be optimally configured for installations from wiring closets to large data centers.
Turn to the typical configurations on page 4 to see examples of how InfraStruXure can be configured.
“
NCPI is the foundation upon which all highly available networks depend. It consists of:
> POWER
> POWER DISTRIBUTION
> RACKS
> CABLE DISTRIBUTION
> INTEGRATED SERVICES
> COOLING
> COOLING DISTRIBUTION
> CABLING
> MANAGEMENT TOOLS
What is InfraStruXure™?InfraStruXure™ is an on-demand architecture for network-criticalphysical infrastructure (NCPI).
THE FOUR LAYERS OF AVAILABILITY - A highly available network depends on people, process,technology, and NCPI. Each availability layer depends upon the layers below it.
I N F R A S T R U X U R E C A P A B I L I T I E S . . .
2
1
3
4
AVAILABILITY
SPEED
> Web-based configuration tool simplifies the design process
> Configure-to-order approach accelerates installation
> Integrated pre-engineered system eliminates need for on-site system test
> Rack-based, standardized modules facilitate quick installation
ADAPTABILITY
> Rack-based modular approach allows system to be easily moved
> Scalable design accommodates changing power densities
> Power distribution system accommodates all receptacle types
> Vendor-neutral enclosure guarantees compatibility with all major IT vendors
COST
> On-demand design prevents oversizing and lowers cost
> Built-in redundancy eliminates need to buy second UPS
> Standardized modules minimize one-time engineering costs
> Integrated cabling and cooling eliminates need for raised floor
> Redundant design of system eliminates single points of failure
> Factory pre-tested system reduces downtime
> Hot-swappable modules lower mean-time-to-recovery
> Proactive management identifies potential problems before they occur
> Locking enclosures provide a secure environment
2
ADAPT TO CHANGING ENVIRONMENTS
M E E T T H E F O U R K E Y C O N S I D E R A T I O N S O F S T R O N G N C P I .
DESIGN AND BUILD DATA CENTERS AND COMPUTER ROOMS QUICKLY
In a world that tolerates zero downtime, system
availability is essential. The only way to ensure optimal
availability is to have a strong NCPI, which is the
foundation of highly available networks.
Today’s business processes are in constant change.
This, in turn, drives new IT requirements. The NCPI that
supports your IT environment must be specified,
designed, and deployed quickly. Unfortunately, it often
takes months to deploy traditional systems.
Traditional NCPI is often expensive to design, install, and
maintain due to one-time engineering costs, high service
requirements, and the underutilization of capacity. A
“pay-as-you-grow” NCPI allows you to scale as required.
MINIMIZE UPFRONT AND OPERATING COSTS
IT PROJECT TIMELINE
TIME TO DEPLOY A
LEGACY NCPI SOLUTION
= TIME REQUIRED TO SPECIFY, DESIGN, BUILD, AND COMMISSION
3 TO 6 MONTHS
3 TO 6 WEEKS
120%
0 1 2 3 4 5 6 7 8 9 10
100%
80%
60%
40%
20%
0%
YEARS
% C
APA
CIT
Y
ACTUAL LOAD
ROOM CAPACITY
EXPECTED LOAD
INSTALLED CAPACITY
Waste due to oversizing
When IT moves, adds or changes become necessary,
they need to happen within days or weeks, not months
or years. As power densities, cabling densities, and
equipment vendors continue to change, the NCPI must
be adaptable enough to respond.
Within the timeframe of just one NCPI refresh, there are typically ten IT refreshes. With each refresh, more demands on the NCPI are made.
0 2 4 6 8 10 12 14 16 18 20YEARS
IT REFRESHES
LEGACY NCPI REFRESHES
= SYSTEM REFRESH
How many opportunities are missed because the NCPI could not be designed and installed quickly enough to meet your changing business requirements?
Traditional NCPI is built based on the expected future loads. If these loads are not quickly realized, waste occurs.
A highly available network depends on people, process, technology, and NCPI. Each availability layer depends upon the layers below it.
INCREASE THE AVAILABILITY AND RELIABILITY OF IT SYSTEMS
1
3
4
h e a t r e m o v e d f r o m t h e r o o m i s e x h a u s t e di n t o c e i l i n g t h r o u g h d u c t sC O M P O N E N T S
“One of the goals of the new building was to consolidate the networks from the existing threebuildings under one roof. This new facility operates on the Cisco Added Solution Voice Over IParchitecture for video, voice, and integrated data, providing network connectivity throughout thefacility. As IT Director, my imperative was to find a watertight solution that would protect ourcommunications infrastructure by guaranteeing uninterrupted power.”
“With InfraStruXure™, I know that no matter what happens, power flow won't be interrupted.
I don't waste time wondering about how many circuits I need to set aside for the panel, or if I needa circuit breaker in the panel. I know InfraStruXure is running behind the scenes, protecting my
equipment, my company, and allowing us to communicate with our customers.”
Because InfraStruXure™ architecture is easy to customize using standardized components, configurations may vary. Here are five
typical InfraStruXure configurations for different size installations. To configure the right InfraStruXure for you, go to page 20.
Industry: Furniture Manufacturing Application: Voice Over IP
Smart-UPS®
Smart-UPS® RT (not shown)
Symmetra® LX (not shown)
P O W E R
Markus M. Hill Director of Technology and Information Services Brayton International
1
INFRASTRUXURE FOR WIRING CLOSETS [ 1 – 3 RACKS ]
2
NetShelter® 2-post OpenFrame Racks
NetShelter® 4-Post OpenFrame Racks (not shown)
Rack PDU (Basic,Metered, and Switched)(not shown)
Rack Accessories (not shown)
NetworkAIR™ PA4000
UPS NetworkManagement Card
EnvironmentalMonitoring Unit (not shown)
R A C K2
C O O L I N G3
M A N A G E M E N T4
S E R V I C EA full range of system- and component-level servicesare available
WIRING CLOSET [ 1-3 RACKS ]
COMPUTER ROOMS[ 1-5 RACKS ]
SMALL DATA CENTERS[ 5-20 RACKS ]
MEDIUM DATA CENTERS[ 20-100 RACKS ]
LARGE DATA CENTERS[ >100 RACKS ]
1
1
2
2
2
5
TYPICAL CONFIGURATIONS
INFRASTRUXURE FOR COMPUTER ROOMS [ 1 – 5 RACKS ]
1
2
4
a i r cond i t i on ing f r om ou ts ide the room i s used to supp lementcoo l i ng w i th in t he room
power routing data routing cold air hot air
To configure the right InfraStruXure™ for you, go to page 20.
"During our four years of operation, we have experienced phenomenal growth. Our systems are critical to thesuccess of our organization. Any downtime risks our reputation."
"Our rapid growth prompted us to bring all outside services in-house, including item and core processing. We built a new operations center. During the design phase of our operations center, we recognized the need to reduce the space required for our systems and we had to pull this off without compromising neatness and cable management."
"InfraStruXure™ costs less than offerings from the competition. It’s an easily managed, fully integrated power andrack solution that affords me the luxury of having to deal with only one vendor. InfraStruXure addressed thepower backup requirements for our centralized servers, and provided us with significant space savings."
Christopher Hutchinson Vice President of Operations First Reliance Bank
Industry: Banking Application: Server Consolidation
LEGEND
P O W E R1
R A C K2
3
5
C O O L I N G M A N A G E M E N T S E R V I C E
1
NetShelter® VX Enclosure
Rack PDU (Basic,Metered, and Switched)
Rack Accessories(not shown)
Rack Air Removal Unit (ARU)
Rack Air Distribution Unit(ADU) (not shown)
NetworkAIR™ PA4000(not shown)
Door Grille Kit
Smart-UPS® (not shown)
Smart-UPS® RT (not shown)
Symmetra® LX
4
10
10
InfraStruXure™ Manager(not shown)
EnvironmentalMonitoring Unit
EnvironmentalManagement System (not shown)
10
6
10
COMPONENTS
1
3
5
5
ho t a i r f r om the rack i s pu l l ed t h rough the ARU ( ) up i n tothe ce i l i ng and re tu rned to t he a i r cond i t i on ing sys tem
4
A full range of system- and component-levelservices are available
6
Mete red Rack PDU ( ) p rov idespower d i s t r i bu t i onand a l l ows on - s i t e i ns ta l l e r s t o mon i to r t he agg rega tecu r ren t d raw
3
InfraStruXure™ 20kW UPSwith Power DistributionUnit (not shown)
Symmetra® PX 40kW UPS
InfraStruXure™ 40kWPower Distribution Unit
XR Battery Enclosure (not shown)
INFRASTRUXURE FOR SMALL DATA CENTERS [ 5 – 20 RACKS ]
1
3
"When we moved our server room to our new eighth floor location, we determined that our power protectionwas inadequate and needed to be upgraded. Initially, we had intended to purchase a generator and an exter-nal uninterruptible power supply (UPS) but we were informed that it would take almost a year to obtainone that would meet our requirements."
"We saw the InfraStruXure as a great fit for our environment. The installation went perfectly. The
components were shipped on time, we wheeled them into our server room and it only took several
hours before the system was installed and started up. The smart cable management inherent in thedesign of the InfraStruXure racks helps us to minimize the risk of human error. We no longer have to worryabout someone accidentally disconnecting the wrong cables."
"Since the power distribution is in the rack and not hard wired into the walls, if we choose to change
locations or expand, we can simply pick up and move our InfraStruXure to a new location without
losing any of our initial investment. If and when our data center load expands, we simply add another rackof properly configured power protection."
Dave Rollins Manager of Technical Services Boston Medical Center HealthNet Plan
Industry: Healthcare Application: Server Room Upgrade
COMPONENTS
P O W E R
R A C K3
C O O L I N G
M A N A G E M E N T
S E R V I C E
1
NetShelter® VX Enclosure
Rack PDU (Basic,Metered, and Switched)(not shown)
Rack Accessories(not shown)
NetworkAIR™ FM 50kW In-Row
High Density Cooling System (not shown)
Rack Air Removal Unit (ARU) (not shown)
Rack Air Distribution Unit (ADU) (not shown)
InfraStruXure™ Manager
EnvironmentalMonitoring Unit (not shown)
EnvironmentalManagement System (not shown)
2
4
2
4
A full range of system- and component-levelservices are available
1
1
3
3
4
4
4
5
4
4
Inf raStruXure ™ Manager ( ) reduces thecomplexi ty of your network-cr i t ical
physical inf rastructure by al lowing you tomanage your APC devices f rom a s ingle
console or by integrat ing into your preferred management system
5
5
“InfraStruXure™ fulfilled three core requirements for us. First, the scalability of the architecture provides us sig-
nificant flexibility in terms of power output and in terms of runtime. Second, our Video on Demand (VOD)servers are air cooled from front to back. The APC racks that house the InfraStruXure are also designed to cool
from front to back. So the same racks can effectively house our power system and our servers. Third,InfraStruXure gives us the ability to monitor our power system remotely. It provides us with battery life data,alarms, environmental monitoring data and greatly increases our ability to forecast and prevent potential failures by establishing an effective and efficient battery replacement cycle. We no longer have to deal with a single point of failure.”
“We wanted an upgradeable solution that could scale through changes and still offer us long-term value.InfraStruXure's modular approach makes it easy to upgrade anytime. With InfraStruXure's pay-as-you-growarchitecture, we haven't had to invest in more than we currently need. With InfraStruXure, I don't have to buy
a significant amount of extra equipment and horsepower upfront that I may or may not have to utilize.”
3
1
2
56
cool a i r is drawn fromthe f loor to where i t is
needed by the ADU ( )
Rich Flanders, Director of Engineering Vince Pombo, VP of Engineering (right) Time Warner Cable
P O W E R R A C K5
M A N A G E M E N T S E R V I C ENetShelter® VX Enclosure
Rack PDU (Basic,Metered, and Switched)(not shown)
Rack Accessories(not shown)
LEGEND
Symmetra® PX 80kW UPS
InfraStruXure™ 80kWPower Distribution Unit
XR Battery Enclosure
InfraStruXure™ RackDistribution Panel (not shown)
InfraStruXure™ Manager(not shown)
EnvironmentalMonitoring Unit (not shown)
EnvironmentalManagement System (not shown)
COMPONENTS
1
2
3
C O O L I N GNetworkAIR™ FM 50kW
High Density CoolingSystem (not shown)
Rack Air Removal Unit (ARU)
Rack Air Distribution Unit (ADU)
6
7
8
7
8
Industry: Communications Application: Video on Demand
8
A full range of system- and component-levelservices are available
INFRASTRUXURE FOR MEDIUM DATA CENTERS [ 20 – 100 RACKS ]
power routing RDP power feed data routing cold air hot air
4
4
5
5
5
5
4
4
INFRASTRUXURE FOR LARGE DATA CENTERS [ >100 RACKS ]
power routing RDP power feed data routing cold air hot air
P O W E R1
R A C K3
M A N A G E M E N T S E R V I C E
2
NetShelter® VX EnclosureRack PDU (Basic,Metered, and Switched)(not shown)
Rack Accessories (not shown)
A full range of system- and component-level services are available
Symmetra® MW UPS InfraStruXure™ 60kWPower DistributionUnit (PDU)
InfraStruXure™ Manager(not shown)
EnvironmentalMonitoring Unit (not shown)
EnvironmentalManagement System (not shown)
COMPONENTS
LEGEND
C O O L I N G
3
3
1
2
35
cool a i r is drawn fromthe f loor to where i t is
needed by the ADU ( )
6
4
1
[ I n s i d e v i e w S y m m e t r a M W ]
NetworkAIR™ FM 50kW High Density CoolingSystem (not shown)
Rack Air Removal Unit (ARU)Rack Air Distribution Unit(ADU) (not shown)
4
5
6
6
OVERVIEW OF INFRASTRUXURE COMPONENTS
RACK (SEE PAGE 14)
> Capable of cooling high-density configurations
> Includes integrated cable management capabilities
> Accommodates increasing server depths
> Easily monitor and control devices over existing IT network
> Manage a single device, multiple devices, or a mixture of device types
> Integrates with Enterprise and Building Management Systems
> High-efficiency solutions provide cooling exactly where required
> Simplified design increases reliability and reduces maintenance requirements
> Flexible solutions perform effectively in non-raised floor environments
> Integrated power distribution eliminates the need for complex powercabling designs
> Built-in redundancy eliminates the need for a second UPS
> Scaleable design lets you buy what you need now, then add power or runtime capabilities later
MANAGEMENT (SEE PAGE 16)
COOLING (SEE PAGE 12)
SERVICES (SEE PAGE 18)
> Full range of turn-key services allow you to focus on your core competencies
> Factory-trained professionals to install, service, and support your systems
InfraStruXure™ architecture has a wide range of integrated componentsand service offerings.
POWER (SEE PAGE 10)
Battery Module: Scalable for more runtime,hot-swappable for easy replacement , N+1redundant
Intelligence Modules: Redundant IntelligenceModules that are hot-swappable
Power Module: Provides flexibility to scalepower, adds N+1 capability, hot-swappable
Robust Frame with Automatic & ManualBypass Switch: Enables the UPS to transferthe load to utility power, without interruption,in case of heavy overload or faulty conditions
D
C
Network and Server UPS
Smart-UPS® XL UPS Smart-UPS® RT UPS
InfraStruXure™ 20kW• PDU and UPS in one footprint saves space
and speeds deployment• N+1 redundancy increases availability• Scalable power capacity lowers cost• Rack-based technology adapts easily to
technology refresh
Smart-UPS® RT UPS • Double conversion on-line
for zero transfer time andtight voltage/frequency regulation
• High power density occupies less space and weighs less• Hot-swappable/user-replaceable batteries ensure
continuous operation of the load• Scalable runtime: unlimited number of matching battery
packs can be added to increase the runtime to thedesired amount
• Manageable via PowerChute Business Edition or UPS Network Management Card
Smart-UPS® XL UPS• Matching battery packs can be added to
meet changing needs• 4th generation line-interactive design
provides proven performance• Hot-swappable battery replacement system
minimizes downtime• Manageable via PowerChute® Business Edition
Symmetra® LX UPS• Modular N+1 redun-
dant design: intelli-gence, power andbattery modules fit ina robust frame forhigh availability
• Scalable power and runtime providesflexibility and lowers initial costs
• User-serviceable modules lower costof ownership and mean time-to-recovery (MTTR)
• Manageable via UPS NetworkManagement Card
POWER COMPONENTS
SYMMETRA® TECHNOLOGY
Symmetra® is designed as a high availability system formission-critical applications. N+1 redundancy ensuresmaximum uptime and near continuous availability. Themodular design makes the Symmetra easy to scale,service, and manage.
A
A
B
B
C
D
Data Center and Facility UPS
RACK 1 STANDALONESTORAGE UNIT
The Configure-to-order (CTO) process allows for the pre-installation of pre-tested breakers, cut-to-size power whips, load-test ports, andmonitoring boards. Factory customization lets you build your InfraStruXure™ to your exact specifications for speed of deployment, high reliability, and cost savings.
RACK 2 RACK 3 RACK 4
• Small footprint minimizes real estateexpenses for non-IT equipment
• Wraparound system bypass isolates UPS from critical load*
• Local or Web-based monitoring for easeof management
• Front and rear access facilitates service
*Not applicable for 60kW PDU
Symmetra® PX 40-80kW UPS• N+1 redundant design for high availability• Scalable power and runtime for flexibility
and lower cost• User-replaceable modules for ease
of service• Rack-based design speeds deployment
Power Distribution Units
For more detailed technical informa-tion on the Symmetra® MW UPS, go to www.apc.com
CONFIGURE-TO-ORDER
Symmetra® MW UPS• Easy system expansion with load
sharing and scalable power modules provides adaptability to changing environments
• N+1 redundant fault-tolerant design provides high availability
• Self-diagnosing function and modular-level repair reduce mean time-to-recovery (MTTR)
• Configurable LCD touch-screen with single-interface management of multiple products
Rack Distribution Panel (RDP)• Power panel placed remotely from main
PDU to enhance power cable management• Accessible input sleeve connector for easy
connection• Variable input cable length for enhanced
flexibility
InfraStruXure™ 40, 60, 80kW PDU
Rack Air Removal Unit (ARU)• Ducted exhaust system removes hot air to pre-
vent re-circulation and eliminate air mixing• Power or temperature controlled fan speed
ensures proper amount of heat removal• Zero ‘U’ solution mounts to the rear of the rack,
leaving valuable rack space free
FM is more efficientDedicated dehumidification cycle maintains higher sensible heat ratiosresulting in up to 15% lower energyconsumption
FM is more reliableDirect drive fans eliminate need forunreliable belts, pulleys, and special-ized bearings
FM is less expensive to maintainEasier, more space-efficient frontaccessCleaning or replacing of insulationeliminated by a double wall paneldesign
FM is more intelligentFrequency controlled fan speed pro-vides easier and faster start up andcheck out
COOLING COMPONENTS
FM TECHNOLOGY VERSUS LEGACY SYSTEMS
NetworkAIR™ PA 4000*• Portable, compact design provides flexibility to
move the unit wherever cooling is required• Automatic restart feature returns unit to its last
operating status in the event of a power failure• On/off scheduling lowers energy costs
Computer Room Air Conditioning
NetworkAIR™ FM*• Built-in Web/SNMP, BMS and configurable
digital I/O interfaces for manageability• Elimination of belts & pulleys increases reli-
ability and reduces maintenance costs• Optional In-Row configuration for hot spots
and high-density aisles
Air Distribution and Fans
Frequency Controlled Drives
Integrated Display
Double Walled Panels
Economizer Coil
Direct Drive Blower/motor Assembly
Intelligent Steam Canister Humidifier
Rack Air Distribution Unit (ADU)• Equalizes rack temperatures from top to bottom• Minimizes air mixing by distributing air from under
the raised floor, directly into the rack• Provides proper intake temperatures, increasing
equipment life• Delivers air where floor tile velocity is inadequate
for cooling
Air Removal Unit Ducting Kit converts rack air removal unit toceiling to duct air from the room *Subject to regional availability
DX Coil
Power Distribution Unit (PDU)
UPS
NetworkAIR™ FMIn-row air conditioner
pulls hot air from the backand distributes cooled air
to the front
Hot Aisle CeilingTiles/Cable Trough
Seals in hot air, preventsmixing with room air
Discharge Air PlenumDistributes cooled air to room Chamber Doors
Access to hot aisle,locks for security
HIGH DENSITY COOLING TECHNOLOGY OVERVIEW
[cold][hot]
[hot] [cold]
High Density Air Conditioning
High Density Cooling System*• Allows for quick deployment of high density
clusters• IT equipment can be moved or changed without
system reconfiguration• Allows for changing needs and future expan-
sion with a pay-as-you-grow architecture• Sealed hot aisle eliminates mixing with cold
supply air to increase availability• Increased cooling capacity and system
efficiency from warmer air return temperatures• UPS-supported fans through dual input power
to cooling system
Raised floor
Non-raised floor
Because most IT equipment cools fromfront to back, an optimal cooling configu-ration is that of hot-aisle, cold-aisle,where rack fronts face other rack fronts,and rack backs face other rack backs.
HOT-AISLE, COLD-AISLE CONFIGURATION
NetShelter® VX• Ventilated doors with scalable
cooling options satisfy varyingthermal requirements of rack-mounted applications
• Recessed power distributionchannels provide easy accessto multiple receptacles occupy-ing zero U
• Cable management channels:easy routing, management, andaccess to power/data cables
• Vendor-neutral mounting forguaranteed compatibility with allEIA-310-D compliant 19” equipment
• Offers a generous 43U of 19”equipment mounting space ina 7’ (2133 mm) high design
• Available with square holesfor servers or threaded holesfor networking gear
• Optional roof allows use oftroughs/partitions
• Self-squaring design makesassembly quick and easy,requiring only one person tofully assemble each unit
Whip Adapter*• Twist-lock input plug provides seamless
integration with multi-branch whip• Plug spacing capable of providing power for
up to (3) low power racks• Available with 5-20, L5-20, and L6-20 receptacles to
exactly match environments
Split rear doorsNetShelter VX wide NetShelter VX 47U
Cable ManagementExtensive options for vertical, horizontal and over-head cable management to facilitate cable routinginside and outside APC racks and enclosures
StabilizationAnti-tip plate for standalone applications andbolt-down brackets for Uniform Building Codefloor anchoring
ShelvingFixed and sliding shelves with weight capacitiesranging from 50-250 pounds (23-113kg)
Troughs and Ladders • Overhead cable management of power and data
cables in shielded partitions• Toolless cable ladders for row-to-row cable routing• Third-party Trough Adapter Kits convert existing
racks to accept overhead power cable troughsand data partitions (for use with non-APC racksin migration environments)
• Adjustable power cable troughs and data parti-tions fit seamlessly into the NetShelter® VX roof
Blanking PanelsAvailable in various heights, essential for proper airflow in racks
Keyboard Drawers1U and 2U keyboard drawers for 17” and19” keyboards
Security DevicesAccessories to enhance the physical securityof your enclosure environment
RACK COMPONENTS
NetShelter® 2- and 4-Post Open Frame Racks
Enclosures
Rack Accessories
Open Frame Racks
“Fits Like a Glove” guarantees that all brands ofEIA-310-D compliant equipment fit inside.
Transfer Switch (ATS)• For solutions with 2 input power sources• Contains any fault to individual rack or server• 1U in height saves space• User configurable settings• Universal twist-lock input plug*
Metered Rack PDUs• Current monitoring with alarm thresholds• Network Ready for remote monitoring• Toolless mounting in NetShelter VX• 3-phase and single-phase units available
Basic Rack PDU• Affordable, simple power
in/power out design• Various amperage options• Both domestic (NEMA) and international
(IEC) versions• Variety of horizontal & vertical mounting solutions• Toolless mounting in NetShelter VX
Switched Rack PDUs• Individual outlet control• Recycle power• Power sequencing• Turn-off unused outlets• Current monitoring with alarm thresholds• Network Ready for remote monitoring• Toolless mounting in NetShelter VX• 3-phase and single-phase units available
Patch PanelsPatch panels, manufactured to industry stan-dards, keep your network up and running
Rack Power Distribution
Rack Connectivity
*Subject to regional availabilityNetwork Patch Cables High quality networking cables keep your net-work up and running
Pictured at right - Metered Rack PDU
POWER AND DATA CABLE ROUTING
Traditional power and cooling system
Overhead cable trays and under-floor cabling systems limit flexi-bility and adaptability. Because the premise is entered, adherenceto the National Electric Code is required. Under-floor, plenum-rated material is expensive and resource-intensive to install.Under-floor branch circuits can negatively affect air distribution.
Self-contained rack-based system
Self-contained, UL-listed (independent CE certified) systemdoes not enter the premise. There is no need for under-floor,plenum-rated material. Toolless installation.
InfraStruXure™ Manager• Centralized management of APC
network-critical physical infrastructure • 1U appliance with licenses for 25, 100,
or 1000 nodes• Notification of threatening situations• Allows you to plan for changes in
availability, power, runtime or cooling• Integrates into your preferred manage-
ment system
From environmental management and UPS management to server
access, APC management solutions increase availability by remotely
monitoring and controlling easily and economically.
Whether managing a single device, multiple devices, or a mixture of
device types, APC management solutions are easy to use and deploy.
APC management solutions work together and independently,
allowing you to monitor devices locally over existing IT networks or
the Web, and to be notified of problems within the system via
e-mail or pager gateway notifications.
MANAGEMENT
Network-critical Physical Infrastructure (NCPI) Management
Multi-device SupportExtensive range of APC devices
Corporate NetworkManage APC networked devicesacross the existing corporate network
Private IP NetworkManage multiple deviceswith one IP address
MANAGE APC DEVICES ON THE CORPORATE OR INFRASTRUXURE NETWORK
Browser AccessibleQuick access from anywhereon the network
Notification GroupsEnsure the right peoplereceive warnings
Device Status SummaryRed: Urgent
Yellow: Needs attentionGreen: Normal
Recommended ActionsReduces training, eases deploy-ment and speeds troubleshooting
LCD Monitor• Occupies only 1U of rack space • 15” TFT active matrix screen provides a
high quality, flicker-free display• Full-size keyboard with 104 full travel keys and
integrated number pad• Low power/cooling requirements compared to a
comparable CRT monitor solution• Solid steel construction with a powder-coat paint finish
KVM Switches• Manage multiple servers with just one keyboard,
monitor and mouse• Multi-platform supports any combination of PS/2, USB
and Sun computers• On-screen display of easy-to-use menus to switch between servers• Plug-and-play operation lets you add or remove servers without hav-
ing to power off the switch• “Keep Alive” feature: attached servers can power the unit in the
event of a power failure• 8 and 16 port versions
Environmental Monitoring System• Browser-accessible 1U rack-mountable appliance • Temperature and humidity monitoring• Monitor third-party devices via 4 input contacts• Control third-party devices via 1 output relays• Early warning notifications to appropriate personnel
Environmental Management
• Browser-accessible 1U rack-mountableappliance
• Monitor a wide range of access and environ-mental conditions
• Monitor third-party devices via 8 input contacts• Control third-party devices via 2 output relays • Early warning notifications to appropriate personnel
ENVIRONMENTAL MANAGEMENT SYSTEM DESIGN BENEFITS
Server Access
UPS Management
1U Rack-mountable Appliance: Remote Management of Access and Environmental Conditions
Environmental Management System
Temperature andHumidityMonitoring: Changesare reported via userinterface or e-mail.
• Embedded management of UPSs protecting servers and networking equipment
• Browser-accessible UPS management• Notification of threatening situations• Reboot of hung equipment• Integrates into your preferred management system
Front view: LCD Status Screen
Alarm Beacon:Quickly locatepotential problems.
Reboot equipment remotely: Turn off outlets not in use or recycle power to locked-upequipment.
Customizable Input Contacts: Monitorconditions from third-party devices that have contact closures.
Customizable Output Relays: Control the outputfrom 2 third-party devices.
Vibration Monitoring:Monitor shock andvibration to equipment.
Access Monitoring:Includes two doorsensors to monitoraccess to equipment.
UPS Network Management Card
Using APC Global Services lets you access project engineering
expertise gained from years of experience designing and imple-
menting complex infrastructure solutions.
An APC certified installation and commissioning of your system
ensures that the equipment is configured for optimal performance.
This saves you time, money, and extends the life of your hardware.
For your convenience, APC offers three InfraStruXure™ Services
packages: Basic, Enhanced, and Comprehensive.
With the option of installation packages or individual service
components, you can pick and choose how APC Global
Services can best serve you.
Needs Assessment ServicesOur APC Certified Field Service Engineer willvisit your site and collect data pertaining toelectrical loads, wiring practices, powerquality, existing power protection equipment,and environmental conditions.
1Installation PlanningWe will meet with you prior to installation tooffer guidance on how to physically positionand connect the APC hardware to your cur-rent infrastructure.
2
Start UpAn APC Certified Field Service Engineer verifiesall connections on your system. Once the unit hasbeen powered up, we ensure it is functioning cor-rectly in all modes of operation. Receive basicoperational instructions to familiarize you with thecomponents of your system.
5Server Migration and Cable ManagementAPC Global Services Network IntegrationEngineers will help plan rack configuration aswell as perform the actual server migrationand cable management. We ensure that yoursolution is configured for optimal airflow andperformance.
6
BasicAn APC Certified Field Service Engineer (FSE) will visit your site to verify allconnections and power up the solution, then test it for proper functionality,ensuring your system has been installed to factory specifications.
EnhancedOur factory trained FSEs will assemble the solution and, once installation iscomplete, perform all functionality tests. With this package, you are onlyresponsible for ensuring the system is wired into the site’s existing infra-structure.
ComprehensiveOur Professional Services Engineers and FSEs will manage your total instal-lation ensuring your system is up and running when you need it.
Network IntegrationNetwork Integration is available as a standalone service, and can be per-formed in conjunction with any of the packages listed to left.
Basic Enhanced Comprehensive Network IntegrationNeeds Assessment
Installation Planning
Project Management
Assembly
Start Up
On-Site Services
Server Migration
Cable Management
Software Integration
�
�
�
��
�
�
�
�
�
�
SYSTEM AND PRODUCT-BASED SERVICES
InfraStruXure™ Installation Project Flow
InfraStruXure Installation Packages and Individual Service Options
Project ManagementIn order to prepare for installation of your new APCsolution, we will make sure all electrical ormechanical contract work is completed in time fordelivery and set up of the system components.
3
Project Management Service• A service designed to help you complete your projects on time and
within budget
Needs Assessment Services• A site survey that supplies you with the information necessary to
design your facilities for optimal performance
Network Integration• The assistance you need to transition from your existing solution to
your new APC solution
Installation Services• A set of service options designed to deliver the vital resources, expertise, and tools needed to
quickly and efficiently implement your APC solution
Preventive Maintenance• An examination of your system designed to ensure optimal performance
On-Site Service• An APC factory-trained technician will arrive on site to diagnose or repair your APC equipment
Extended Warranty• An extension of coverage beyond the factory warranty
Remote Monitoring Service• Expert outsourced monitoring via APC's InfraStruXure™ Manager
Professional Services
Product-based Services
“APC customer service continues to beunparalleled in today’s market.
“Our InfraStruXure just rolled into placeand plugged in, quick and easy. Evenwith all the extra people, the installationand user training took only four hours.Every APC professional was very conscien-tious, right down to being careful not toscratch the parquet floor. They evenshowed us some cable management tech-niques that made things easier.”
Steve Painter Senior Vice-President, Information Systems ACIS
AssemblyOnce your equipment has arrived, we will unpack allcomponents, dispose of all packaging, position theequipment in place, assemble the racks and popu-late them with UPS and PDU components.
4
Software IntegrationOnce all your network components are installed,our Network Integration Engineers will installand configure all APC software, making sureyour network is being monitored the way youwant it to be.
7APC On-Site Repair Our Field Service Engineers are trained to isolateand correct the problem as quickly as possible.APC offers flexibility with 4 Hour, Next Day andNext Business Day response times.
8
Industry: Education Application: New Data Center
The InfraStruXure™ BuildOut Tool lets you design and specifyInfraStruXure solutions using a Web-based configurator.
5 EASY STEPS TO BUILD YOUR INFRASTRUXURE
"InfraStruXure is the only complete power architecture avail-able on the market today. Now a client can acquire a rack,power distribution unit (PDU), UPS, environmental monitor-ing, cables, cable management, and software as one tightlyintegrated solution from one vendor. In addition, the archi-tecture permits the realization of huge time savings inthe electrical installation process. This is the first 3-phase architecture they’ve seen that literally installs inhours rather than in days or even weeks."
"The APC InfraStruXure Configure to Order (CTO) processhelps to build the customer’s confidence level by rapidly deliv-ering customized, yet integrated, power components to thecustomer’s data center location. The easy access we have toAPC support and technical staff, as well as the new, stateof the art InfraStruXure configuration Build Out Tool (BOT),make InfraStruXure a simple, painless solution to install."
Paul Robinson Data/Voice Division Carlyle, Inc.
Take these 5 easy steps to configure your ideal InfraStruXure solution.
Specify number of racks (See floor layout below)
Define load per rack or total load
Specify runtime
Choose, price, value or performance solution
Customize as desired
12345
Web-based BuildOut Tool
To learn more about InfraStruXure and the BuildOut Tool, visit us at www.infrastruxure.com
Go to our APC Authorized/CertifiedPartner locator at www.apc.com underthe ‘How to Buy’ Section.(See Web-based Tool below)
Need an expertsite review?
Application: Manufacturing Industry: Voice Over IP
APC’s innovative InfraStruXure Buildout Tool has been acknowledgedwith a 2003 Computerworld Medal of Achievement.
Floor LayoutDraw your ideal floor plan and specify the number of racks
Overview of price, value, and performance solution and its budgetary price
The NASDAQ-100 Index is composed ofthe 100 largest non-financial stocks onthe NASDAQ stock market.
Information Week identifies the most innovativeusers of IT from U.S. companies with $1 billion ormore in annual revenues.- Awarded 2003, for the fourth year in a row.
• For over 20 years APC has advanced new availability
technologies through forward-reaching research and
development.
• Propelled by real-world experience and a drive
towards technological innovation, APC has the
experience, scale, global presence, and stability
required to respond to emerging IT availability trends.
• Our corporate culture is dedicated to a single purpose,
with employees worldwide ensuring availability
wherever data is created, transmitted or stored.
• Our products range from surge suppressors, uninter-
ruptible power supplies (UPS), cabling, connectivity
products, precision cooling solutions, DC power
systems, and management software to consulting
and professional services.
• With no long-term debt and a strong financial
position, APC supports an active and on-going
research and development program.
• Over 15 million valued customers worldwide and
hundreds of industry-related awards are the result of
our ability to solve real-world availability problems.
APC offers presence and
partners across the globe,
delivering peace of mind no
matter where your needs lie.
COMPANY PROFILE
©2004. All rights reserved. All APC trademarks are property of American Power Conversion Corporation. Other trademarks are property of their respective owners. Specifications are subject to change without notice. PART# 996-2595C
APC’s ManufacturingSystem is certified by ISO 9001 and ISO 14001Standards
Visit: www.apc.comE-mail: [email protected] Support: support.apc.com
For moreinformation call:Tel: 888 289 APCC x2700
- US & CanadaTel: 401 789 0204
- Worldwide
APC CorporateAPC North America& Latin America132 Fairgrounds Road,West Kingston,RI 02892 USACall: 888 289 APCC x2700Fax: 401 789 3710
APC EuropeAPC IrelandBallybrit Business Park, Galway, IrelandCall: +35 391 702000Fax: +35 391 756909
APC Asia PacificAPC Australia Pty LtdLevel 13, The Denison 65 Berry StreetNorth Sydney,NSW 2060Call: +61 2 9955 9366Fax: +61 2 9955 2844
APC Latin America5301 Blue Lagoon Dr.Suite #610Miami,FL 33126, USACall: 305 266 5005Fax: 305 266 9695
To receive a FREE APC White Paper on “Determining Total Cost of Ownership for Data Center andNetwork Room Infrastructure”, please visit us online at http://promo.apc.com and enter key codej228y, call 888-289-APCC x2700, or fax 401-788-2797. Other APC white papers are also available.
Winner of the Communications Solutions Magazine’s “2002 Product of the Year” award.Winner of the 2002 Internet Telephony “Product of the Year Award”, and the GCN “Best
New Technology Award” at FOSE, March, 2002.(Awarded to PowerStruXure™, which is now included under the InfraStruXure™ brand.)
InfraStruXureTM architecture is designed to handle the real-world challenge of high power densities in IT environments. Our newest solution is the High Density Cooling System shown below. Using quick-to-deploy high density clusters, the High Density Cooling System is flexible enough to be moved orchanged without system reconfiguration. You can also scale it to meet changing needs and future expansion.
HIGH DENSITY COOLING UP TO 20KW IN A SINGLE ENCLOSURE
Hot Aisle Ceiling Tiles/Cable Trough
Seals in hot air, preventsmixing with room air
NetworkAIR FMTM
In-row air conditionercools hot chamber air
Power Distribution Unit (PDU)
UPS
Chamber DoorsAccess to hot aisle,locks for security
For more information on the High Density Cooling System and other InfraStruXure™
cooling solutions, see pages 12-13.
Determining Total
Cost of Ownership
for Data Center and
Network Room
Infrastructure