INERT GAS SYSTEM
Operation & Maintenance Graphical LCD operator terminal,
all major process parameters displayed
on the screen.
Burner combustion chamber in high
performance austenitic stainless steel
(ASTM N08904).
Easy access to burner and combustion
chamber by hinged burner front door
(no tools required).
Easy inspection and easy replacement
of scrubber components by entering
man hole and removable top plate.
Easy installation, panels are
connected via two pair serial data
wires + power supply (2 wires).
Options Multiple LCD operator terminals.
System signals and operation
available for ships IAS via MODBUS
or ETHERNET communication.
Brief Description Inert gas generation produce clean and
soot free inert gas by combustion of
air and gas fuel in Maritime Protection
burner/combustion chamber.
Automatic O2 regulation by
venturi and fuel pump motor
speed controller.
Efficientcoolingin
scrubber tower.
High pressure centrifugal
blower supplies air to burner
chamber and provides inert
gas to cargo tanks.
System capacity is auto-
matically controlled by
deck pressure set-point in
software.
Maritime Protection
Pressure Vacume
Breaker ensure safe
loading and
off loading.
Advantages Full automatic turn down (fuel saver)
Fully Automatic operated, no manual
operation (O2 content,IG-flow,alarmsetc.)
Easy maintenance
Oil spill prevention
Experience from continuous testing and delivered
projects are incorporated in our latest design
All generator units have a horizontal, recessed combus-
tion chamber. This construction retains fuel oil that, in
aeventofmisfire,wouldotherwisebedishargedover-
board. The PLC control logic has a specially designed
burnerignitionsequencethatwillensureaflawlessigni-
tion of the unit every time, hence further eliminating the
possibilityofaflamefailure.
LCD operator terminalFrom the terminal you can:
Start & stop the IG generator system.
Monitor valve positions and motor running status.
Change O2 set-point.
Monitor process and status indication.
Monitor alarm and change alarm set points.
Change controller set points and parameters.
P/V -breakerIG diagram Deck water seal
PRODUCT TYPES:
INERT GAS GENERATOR: hFO/MGO/MDO/GAS fueled generator for inerting tankers.
FLEX SYSTEMS: Inert gas generator system in combination with exhaust gas from main engine or auxilary engines for fuel saving.
FLUE-GEN systems: Normal generator + flexinert venturi. Can be operated in two modes: 1. Generator mode 2. Fluegas mode with suction of flue gas from boilers through flex venturi and scrubbing in generator.
DUAL FUEL SYSTEMS: IGG, dual fuel-capable to use natural gas or mgo/mdo/hfo as fuel for inerting fpso’s/fsu’s.
INERT GAS GENERATOR DECK hOUSE MODULE: Application are tankers, fpso’s and oil barges. All systems and capacities available.
All our inert gas systems are skid mounted ready for hook-up.
LCD operator terminal
IG deck house model
TYPE INERT GASCAPACITY[m3/h]
SEAwATERCONSUMPTION[m3/h]
FUELCONSUMPTION[kg/h]
POwER CONSUMPTION[kw]
DIMENSIONL x w x h[mm]
wEIGhT[kg]
MPG-400 500 30 37,5 7,5 1830x800x2225 1150
MPG-700 500-2200 30-132 37,5-165 7,5-33 3000x1000x2800 1500
MPG-800 2200-3200 132-192 165-240 33-48 3300x1100x2800 1900
MPG-900 3200-4500 192-270 240-337 48-67,5 3600x1200x4000 2200
MPG-1000 4500-5700 270-342 337-427 67,5-85 4000x1400x4500 2500
MPG-1100 5700-6800 342-408 427-510 85-102 4500x1400x4500 3000
MPG-1300 6800-10500 408-630 510-787 102-157 5400x1800x4800 5000
MPG-1600 10500-16000 630-960 787-1200 157-240 6000x2100x5025 7000
MPG-1600L 16000-17500 960-1050 1200-1312 240-262 7000x2100x5025 9000
TEChNICAL SPECIFICATIONSTable based on 3% O2 content by volume, pressure 400 mm WC and temperature 25oC.
CO <100ppm NOX<100 ppm N2 = Balance Normal discharge pressure to cargo tank: 400 mm WC
SO2<1ppm CO2 approx. 14% Gas outlet temperature: Max. 8oC above seawater temperature
Oxygen content adjustable down to 1%. Gas outlet humidity: 100% saturated Fuel: MDO/HFO/GASOIL/GAS
GAS COMPOSITION wITh MARINE GAS OIL (MGO)
Service:Service and/or repairs can be carried out in a short notice, world wide.
After Sales:When spare parts or consumables are needed, our After Sales Department is at your service 24 hours a day.
Contact us:E-mail: [email protected] [email protected] [email protected] [email protected]: www.maritimeprotection.noPhone: +47 908 15 987Fax: +47 38 01 10 25Visiting address: Bosmyrkollen 2, N-4620 Kristiansand, NorwayOrganization no.: 894 038 322
Qualified
Achilles JQS
MARITIME PROTECTION IS A hIGhLY REPUTATED COMPANY IN ThE ShIPPING INDUSTRY AND ONE OF ThE LEADING SUPPLIERS OF INERT GAS SYSTEMS. MARITIME PROTECTION
INERT GAS SYSTEMS hAVE BEEN INSTALLED ON MORE ThAN 1,000 OIL TANKERS, PRODUCT TANKERS, BARGES, FPSO’S AND GAS CARRIERS wORLD wIDE.
MARITIME PROTECTION IS FULLY OwNED BY wILhELMSEN TEChNICAL SOLUTIONS.
Wilhelmsen Technical Solutions is part of Wilhelmsen Maritime Services, a Wilh. Wilhelmsen group company. It is a global provider of cost efficient, fully engineered solutions, equipment
and services for new-builds and retrofits in the maritime and offshore industries. Our expertise includes fire suppression and prevention, water treatment, heating, ventilation, air-conditioning and refrigeration (HVAC-R), power optimization,
power distribution and control systems. Wilhelmsen Technical Solutions designs, produces, installs, commissions and maintains its solutions for the lifetime of customers’ vessels, rigs and platforms.