Industrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION LARS OLANDER, LORRAINE CONROY, ILPO KULMALA, RICHARD P. GARRISON, MICHAEL ELLENBECKER, BERNHARD BIEGERT, BERNARD FLETCHER, HOWARD D. GOODFELLOW, GUNNAR ROSÉN, BENGT LJUNGQVIST, BERIT REINMÜLLER, ANTONIO DUMAS, MICHAEL ROBINSON, DEREK B. INGHAM, ALBRECHT LOMMEL, KATSUHIKO TSUJI, IRMA WELLING, XIANYUN WEN

Transcript of Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ......

Page 1: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Industrial Ventilation DesignGuidebookChapter 10

LOCAL VENTILATIONLARS OLANDER, LORRAINE CONROY, ILPO KULMALA,RICHARD P. GARRISON, MICHAEL ELLENBECKER, BERNHARD BIEGERT, BERNARD FLETCHER, HOWARD D. GOODFELLOW, GUNNAR ROSÉN,BENGT LJUNGQVIST, BERIT REINMÜLLER, ANTONIO DUMAS, MICHAEL ROBINSON, DEREK B. INGHAM, ALBRECHT LOMMEL, KATSUHIKO TSUJI, IRMA WELLING, XIANYUN WEN

Page 2: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

LOCAL VENTILATION

Short definition:Local Ventilation systems are used to transport contaminants or heat from the occupancy zone.

Page 3: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

LOCAL VENTILATIONLong definition:

Local Ventilation uses an air flow rate that is as low as possible, but sufficient to minimise the amount of airborne contaminants entering a specified volume or passing specified point(s). Theseare usually intended to be at the breathing zone of occupants. This minimisation of air flow can be achieved either by capturing (or containing) the airborne contaminant into an exhaust hood before it enters the workspace, by blowing non-contaminated air from a supply inlet through the volume to prevent the contaminant from entering the workspace, or a combination of those.

Page 4: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Local Ventilation Modes

Flexible. The suction opening or supply device is placed inside a limitedarea or volume. The exhaust (or supply) opening and duct (or tube) is connected to the fan by moveable elbows or flexible tubes. One exampleis a wall mounted hood for welding exhaust.

Fixed. No changes to the system, except perhaps opening and closing oflids and doors, are possible. One example is the laboratory fume hood.

Mobile. The exhaust (supply) opening may be placed almost anywhere inside a workroom. The whole system (exhaust/supply opening, duct, fan) is on wheels or a portable frame. Or a separate exhaust part (opening and short tube) is connected to a central duct system at many places. One example is a welding exhaust (with filter) on a small carriage and another is a centralized exhaust system for connection to car exhaust pipes. It also includes portable systems.

Page 5: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to
Page 6: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Description of each Local Ventilation system

General commentsPrinciple, including sketches and/or figuresApplicability of contaminant sourcesDifferent forms and boundaries to other typesRelative location of supply and exhaust openings and source(s)Location of worker and tools relative to exhaust and source(s)DisturbancesSpecific problemsChanging flow ratesDesign equations and/or parametersEvaluation procedures

Page 7: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Velocity distributions outside round (top left), round with flange (top right),and square (bottom) exhaust opening.

Page 8: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to
Page 9: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

T h e a ir sh o w er p rin c ip le c rea te s a zo n e o f c lean a ir a ro u n d th e w o rk er an dp u sh es aw ay th e co n tam in an t p lu m e fro m th e b rea th in g zo n e .

Page 10: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Examples of principal arrangements of open unidirectional airflow benches.

Page 11: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

A push-pull system is a combination of an exhaust and an inlet system.

Page 12: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

A schematic representation of the Aaberg principle in acombined exhaust-supply system.

Page 13: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

D.Gubler: REEXS – Reinforced Exhaust System, Optimization ofoperating and design parameters. ETS Switzerland, 2002.

Page 14: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Principe for auxiliary air supply to a laboratory fume hood.

Page 15: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

The Class III Biological Safety Cabinet is a combined exhaust-supplysystem. A: Glove ports with O-ring for attaching arm-length gloves tocabinet. B: Sash. C: Exhaust HEPA filter. D: Supply HEPA filter. E:Double-ended autoclave or pass-through box. Note: Connection of theexhaust to building exhaust system is required.

Page 16: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Different configurations of supply air inlets and exhaust air outlets in an abrasive blasting room. A1: Supply in ceiling and exhaust through floor. A2: Supply in ceiling and exhaust along floor sides. A3: Supply in one end of ceiling and exhaust through one opposite wall. A4: Supply in one end of ceiling and exhaust in corners of opposite wall. B1: Supply in one wall and exhaust through opposite wall. B2: Supply in one wall and exhaust in corners of opposite wall. B3: Supply in corners of one wall and exhaust through opposite wall. B4: Supply in corners of one wall and exhaust in corners of opposite wall. C1 and C2: Not recommended (INRS, 1994).

Page 17: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to
Page 18: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

EVALUATION OF LOCAL VENTILATION SYSTEMS

The evaluation methods could be direct, e.g., measuring a containment index, or indirect, e.g., measuring pressure loss or velocity distribution.

Page 19: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Indirect methods are used to determine regulatory compliance. For example, specified minimum and maximum face velocities for laboratory fume hoods and static pressure (negative) inside enclosed hoods. Monitoring instruments can be connected to alarms. Capture efficiency is the fraction of generated contaminant that is directly captured by the hood. This means measuring concentration of process-generated contaminant or a tracer material. Using contaminant requires instruments suited to each specific contaminant and its conditions. It is easier to use a tracer. Simple evaluations by checking the air flow rates into the opening, presuming that many parameters have not changed since the detailed evaluation was done. Static pressure loss for a hood can be used to monitor the flow rate into the hood. If the flow rate and the pressure loss were measured at the same time as the efficiency, the pressure loss can be used for monitoring hood performance. Another simple way is to use smoke to visualize the air streamlines. It is sometimes possible to see how far an exhaust reaches by observing smoke movement.

Page 20: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Containment indices such as: Protection factor and similar. Leakage factor and similar.Pressure difference. Opening velocity.

Capture efficiency,Capture velocity

Evaluation procedures

Booths, Laboratory fume hoods,Safety cabinets, Glove boxes,Storage cabinets, Built-in processes

Basic openings,Rim exhausts,LVHV, Receptor hoods,Special: Fit to machines

Hood types

EnclosuresExterior hoods

Page 21: Industrial Ventilation Design Guidebook Chapter 10 … Ventilation Design Guidebook Chapter 10 ... on a small carriage and another is a centralized exhaust system for connection to

Thank you!

Lars OlanderProfessorBuilding Services EngineeringRoyal Institute of Technology (KTH)SE-10044 [email protected]