INDUSTRIAL POWER SUPPLYattachments.temcoindustrialpower.com/.../WEG-ESWS... · ESWS-50V24E-RM38 HP...
Transcript of INDUSTRIAL POWER SUPPLYattachments.temcoindustrialpower.com/.../WEG-ESWS... · ESWS-50V24E-RM38 HP...
Corporate Headquarters: TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538 Inside USA (800) 613-2290 International (510) 490-2187 Fax (510) 490-1507 www.temcoindustrialpower.com
WEG Magnetic Motor Starters ESW Series
Dimensions, weight, and impedeance may vary slightly from the information provided. For certified drawings, please contact a TEMCo representative.
INDUSTRIAL POWER SUPPLY
ESWS-50V24E-RM38
HP at 115V:
HP at 230V:
Overload Range Min (A):
Overload Range Max (A):
Coil Voltage:
Phase:
Frequency:
Enclosure Rating:
Enclosure Material:
Push Button:
Weight:
Approvals:
Warranty:
n/a
7.5 HP
32
50
208 - 240 V
Single
60 Hz
NEMA 1
Steel
Reset
5.5 lbs
UL Listed, CSA Approved,
IEC Certified
18 months
Enclosed full voltage magnetic starters are the most commonly used devices used to switch
AC motor loads. Non-reversing non-combination starter consisting of a contactor and a
bimetallic overlaoad relay assembled together inside a NEMA type 1 enclosure.
Standard Features:
- NEMA Type 1 enclosure
- High horsepower ratings in four compact sizes
- Fast acceleration and high initial torque
- Bimetallic overload relays - class 10
- Adjustable trip current
- Ambient temperature compensated for -4°F to +140°F eliminating the need for heaters
- Phase-loss sensitivity protection
- Selectable manual or automatic RESET
- Electrically isolated NO-NC auxiliary contacts
- Easy to install and setup
- UL, IEC, and CSA certified
1-800-ASK-4WEG
www.weg.net
ENCLOSED STARTERS
Data is subject to change without notice.B-174
Dimensions (approx. inches)
Enclosed StartersEnclosure Size
BOX H W D
ESW(S) 9, 12, 18, 25, 32 M04 9.5 5.5 5.0
ESW(S) 40, 50, 65, 80 M06 13.0 7.5 5.6
ESW 95, 105 M08 17.8 9.5 6.7
Single-phase Starter
WIRINg DIAgRAM
DIMENSIONS
Provision for cable gland fitting
Standard
Top Bottom Side Back
Box M042x (½” or ¾”) 2x (½” or ¾”) 4x (½” or ¾”) 2x (½” or ¾”)
1x (¾” or 1”) 1x (¾” or 1”) - -
Box M061x (½” or ¾”) 1x (½” or ¾”) 3x (½” or ¾”) -
2x (1” or 1-1/4” ) 2x (1” or 1-1/4” ) 4x (1” or 1-1/4” ) -
Box M081x (1”) 1x (1”) 1x (1”) 1x (1”)
1x (1-1/2”) 1x (1-1/2”) 4x (¾”) -
Three-phase Starter Separate Control
Pilot Devices
Controls Enclosed Non-Combination Starters - ESW Series
95
96
“D”
95
96
“D”A1
3/1
3/1
4
4
A1
A1
95
96
“D”A1
3/1
3/1
4
4
A1
A1
95
96
“D”A1
3/1
3/1
4
4
A1
A1
2 Wire Control 3 Wire Control
FOR SEPARATE CONTROL, REMOVE WIRES "C" AND "D" IF SUPPLIED AND
CONNECT SEPARATE CONTROL LINES TO TERMINAL Nº 96 ON THE OVERLOAD
RELAY AND TO TERMINAL Nº _3 ON THE AUX. CONTACT BLOCK (FOR 3 WIRE
CONTROL) OR TO THE CONTACTOR COIL Nº A1 (FOR 2 WIRE CONTROL).
95
96
“D”A1
3/1
3/1
4
4
A1
A1
Hand-Off Auto Wire Control(For ESW Series Only)
APG2010 B.indd 174 6/17/10 4:23 PM