INDUSTRIAL GRADE - Nexans

10
INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING POWER CABLES

Transcript of INDUSTRIAL GRADE - Nexans

Page 1: INDUSTRIAL GRADE - Nexans

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING POWER CABLES

Page 2: INDUSTRIAL GRADE - Nexans

INSULATION 90°C ethylene-propylene rubber (EPR)

JACKET1 Black thermosetting Chlorinated Polyethylene (CPE) Jacket cured for easy stripping and cable preparation. Cable identification via permanent marking. AMERCABLE E97865 TYPE G-GC [Size] 3/C 2000V 90C WET OR DRY (UL) SUN RES OIL RESISTANT 60C -40C FT5 [MSHA}

CONDUCTORS Bare copper

GROUND WIRES (2) Bare copper with polyester tape separator and covered with green EPR. Also available with uncovered ground.

GROUND CHECK CONDUCTOR2 Bare copper with polyester tape separator and covered with yellow Ethylene Propylene Rubber (EPR).

37-442

TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 2000 VOLTS

Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613

,FEATURES � Highly durable, abrasion-resistant CPE jacket specially designed

and cured for easy stripping � Outstanding Nexans AmerCable engineering support

APPLICATION Manufactured for use with static or slow-moving industrial equipment, including light-duty mining applications. Nexans AmerCable INDUSTRIAL GRADE Type G-GC features a reinforced jacket that is specially designed for easy stripping and cable preparation.

This cable is designed for applications where grounding conductors and a ground check conductor are required. Recommended maximum continuous conductor temperature is 90°C. Suitable for shallow water submersion when correctly terminated and sealed.

Cable carries “MSHA” marking indicating listing by the Mine Safety and Health Administration and the Pennsylvania Department of Environmental Protection.

Nexans AmerCable INDUSTRIAL GRADE cable meets or exceeds the material requirements of ICEA Standards S-75-381/NEMA WC-58.

RATINGS & APPROVALS � Mine Safety & Health Administration (MSHA) � Pennsylvania Department of Environmental Protection � UL listed Type G-GC meeting requirements of UL 1650

and UL portable power cable file E97865

Specially Designed &

Cured CPE Jacket for Easier, Faster

Stripping!

________

CSA constructions

available upon request

SIZE AWG

8 6 4 2 1

1/0 2/0 3/0 4/0 250 350 500

SIZE AWG

10 10 8 7 6 5 4 2 2 2

1/0 2/0

NO. OF

WIRES PER CONDUCTOR

133 259 259 259 259 266 323 418 532 627 888

1221

NO. OF

WIRES PER CONDUCTOR

49 49

133 133 133 133 259 259 259 259 266 323

INSULATION THICKNESS

MILS

60 60 60 60 80 80 80 80 80 95 95 95

NOMINAL OUTSIDE

DIMENSIONS IN.

1.097 1.105 1.168 1.357 1.470 1.600 1.692 1.920 2.019 2.306 2.580 2.935

SIZE AWG

10 10 10 10 8 8 8 8 8 8 8 8

APPROX. WEIGHT LBS. PER 1,000 FT.

649 770 982

1404 1764 2093 2450 3084 3663 4442 6073 7929

AMPACITY* 30°C

AMBIENT TEMP

65 87

114 152 177 205 237 274 316 352 433 536

37-442-

008 006 004 002 001 010 020 030 040 250 350 500

GROUNDING CONDUCTORS GROUND CHECK

POWER CONDUCTORS

1 Jacket – Heavy-Duty (HD) black CPE is standard. Colored HD CPE jackets available upon request. 2 Ground Check Conductor – Minimum 49 strands (7X7). EP insulation for EASY STRIPABILITY.

.030" minimum average insulation for 10 AWG.

.045" minimum average insulation for 8 AWG *Ampacity – Based on continuous duty at 90°C conductor temperature.

Page 3: INDUSTRIAL GRADE - Nexans

350 Bailey Road • El Dorado, Arkansas USA • www.AmerCable.nexans.com • e-mail: [email protected]_17

37-443

TYPE G 4/C HIGHLY DURABLE EASY-STRIP JACKET 2000 VOLTS

FEATURES � Highly durable, abrasion-resistant CPE jacket specially designed

and cured for easy stripping � Outstanding Nexans AmerCable engineering support

APPLICATION Manufactured for use with static or slow-moving industrial equipment, including light-duty mining applications, or three-phase AC systems which require a ground. Nexans AmerCable INDUSTRIAL GRADE Type G features a reinforced jacket that is specially designed and cured for easy stripping and cable preparation.

Recommended maximum continuous conductor temperature is 90°C. Suitable for shallow water submersion when correctly terminated and sealed.

Cable carries MSHA marking indicating listing by the Mine Safety and Health Administration and the Pennsylvania Department of Environmental Protection.

Nexans AmerCable INDUSTRIAL GRADE Cable meets or exceeds CSA C 22.2 #96, ASTM B-172 and B-3.

RATINGS & APPROVALS � Mine Safety & Health Administration (MSHA)

� Pennsylvania Department of Environmental Protection � UL listed Type G meeting requirements of UL 1650

and UL portable power cable file E97865

INSULATION 90°C ethylene-propylene rubber (EPR)

JACKET1 Black thermosetting Chlorinated Polyethylene (CPE) Jacket cured for easy stripping and cable preparation. Cable identification via permanent marking: AMERCABLE (UL) TYPE G [SIZE] 4/C 90C WET OR DRY 2000V SUN RES OIL RESISTANT 60C -40C FT5 [MSHA]

CONDUCTORS Bare copper

GROUND WIRES (4) Bare copper insulated with green EP1140

________

1 Jacket – Black Heavy-Duty (HD) CPE is standard. Colored HD CPE jackets available upon request. *Ampacity – Based on continuous duty at 90°C conductor temperature, with not more than three current carrying conductors.

SIZE AWG

8 6 4 2 1

1/0 2/0 3/0 4/0 250 350 500

SIZE AWG

12 12 10 8 8 7 6 5 4 3 2

1/0

NO. OF

WIRES PER CONDUCTOR

133 133 259 259 259 266 323 418 532 627 888

1221

INSULATION THICKNESS

MILS

60 60 60 60 80 80 80 80 80 95 95 95

NOMINAL OUTSIDE

DIMENSIONS IN.

1.109 1.165 1.309 1.445 1.630 1.803 1.915 2.080 2.215 2.590 2.900 3.300

APPROX. WEIGHT LBS. PER 1,000 FT.

754 913

1214 1728 2164 2614 3139 3766 4583 6028 7674

10797

37-443-

008BC 006BC 004BC 002BC 001BC 010BC 020BC 030BC 040BC 250BC 350BC 500BC

GROUNDING CONDUCTORSPOWER CONDUCTORS

Specially Designed &

Cured CPE Jacket for Easier, Faster

Stripping!

NO. OF WIRES PER

CONDUCTOR

19 19 49

133 133 133 133 133 259 259 259 266

CSA constructions

available upon request

AMPACITY* 30°C

AMBIENT TEMP

65 87

114 152 177 205 237 274 316 352 433 536

Page 4: INDUSTRIAL GRADE - Nexans

Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613

37-401

TYPE W 1/C PORTABLE POWER•EASY-STRIP JACKET 2000 VOLTS

FEATURES � Highly durable, abrasion-resistant CPE jacket specially designed

and cured for easy stripping � Outstanding Nexans AmerCable engineering support

APPLICATION Manufactured for heavy-duty or temporary power supply service, AC or DC, to motor or generator, portable and stationary heavy-duty equipment, cranes, conveyors and other mobile equipment applications. Nexans AmerCable INDUSTRIAL GRADE Type W features a reinforced jacket that is specially designed and cured for easy stripping and cable preparation.

Recommended maximum continuous conductor temperature is 90°C. Suitable for installation in air, ducts, shallow water or direct burial.

Cable carries MSHA marking indicating listing by the Mine Safety and Health Administration and the Pennsylvania Department of Environmental Protection.

Nexans AmerCable INDUSTRIAL GRADE cable meets or exceeds the material requirements of ICEA Standards S-75-381/ NEMA WC-58.

RATINGS & APPROVALS � Mine Safety & Health Administration (MSHA) � Pennsylvania Department of Environmental Protection � UL listed Type W meeting requirements of UL 1650

and UL portable power cable file E97865

INSULATION 90°C ethylene-propylene rubber (EPR)

JACKET1 Black thermosetting Chlorinated Polyethylene (CPE) Jacket cured for easy stripping and cable preparation. Cable identification via permanent marking: AMERCABLE (UL) TYPE W [SIZE] 1/C 90C WET OR DRY 2000V SUN RES OIL RESISTANT 60C -40C FT5 [MSHA]

CONDUCTORS Bare copper

SEPARATOR For easy stripping of insulation

Specially Designed &

Cured CPE Jacket for Easier, Faster

Stripping!

________

CSA constructions

available upon request

Page 5: INDUSTRIAL GRADE - Nexans

350 Bailey Road • El Dorado, Arkansas USA • www.AmerCable.nexans.com • e-mail: [email protected]

1 Jacket – Black Heavy-Duty (HD) CPE is standard. Colored HD CPE jackets available upon request.

SIZE AWG

8 6 4 2 1

1/0 2/0 3/0 4/0 250 350 500

NO. OF

WIRES PER CONDUCTOR

133 133 259 259 259 266 323 418 532 627 888

1221

INSULATION THICKNESS

MILS

60 60 60 60 80 80 80 80 80 95 95 95

NOMINAL OUTSIDE

DIMENSIONS IN.

0.448 0.522 0.584 0.655 0.731 0.780 0.830 0.896 0.956 1.025 1.155 1.300

APPROX. WEIGHT LBS. PER 1,000 FT.

137 196 264 360 467 542 635 780 929

1097 1472 1965

37-401-

008BC 006BC 004BC 002BC 001BC 010BC 020BC 030BC 040BC 250BC 350BC 500BC

AMPACITY* 30°C

AMBIENT TEMP

80 105 140 190 220 260 300 350 405 455 570 700

TYPE W 1/C

Page 6: INDUSTRIAL GRADE - Nexans

Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613

37-430/31

TYPE W 2-3/C PORTABLE POWER•EASY-STRIP JACKET 600/2000 VOLTS

FEATURES � Highly durable, abrasion-resistant CPE jacket specially designed

and cured for easy stripping � Outstanding Nexans AmerCable engineering support

APPLICATION Manufactured for heavy-duty or temporary power supply service, AC or DC, to motor or generator, portable and stationary heavy-duty equipment, cranes, conveyors and other mobile equipment applications. Nexans AmerCable INDUSTRIAL GRADE Type W features a reinforced jacket that is specially designed and cured for easy stripping and cable preparation.

Recommended maximum continuous conductor temperature is 90°C. Suitable for installation in air, ducts, shallow water or direct burial.

Cable carries MSHA marking indicating listing by the Mine Safety and Health Administration and the Pennsylvania Department of Environmental Protection.

Nexans AmerCable INDUSTRIAL GRADE cable meets or exceeds the material requirements of ICEA Standards S-75-381/ NEMA WC-58.

RATINGS & APPROVALS � Mine Safety & Health Administration (MSHA) � Pennsylvania Department of Environmental Protection � UL listed Type W meeting requirements of UL 1650

and UL portable power cable file E97865

INSULATION 90°C ethylene-propylene rubber (EPR)

JACKET1 Black thermosetting Chlorinated Polyethylene (CPE) Jacket cured for easy stripping and cable preparation. Cable identification via permanent marking: AMERCABLE (UL) TYPE W [SIZE] #/C 90C WET OR DRY 2000V SUN RES OIL RESISTANT 60C -40C FT5 [MSHA]

CONDUCTORS Bare copper

SEPARATOR For easy stripping of insulation

Specially Designed &

Cured CPE Jacket for Easier, Faster

Stripping!

________

CSA constructions

available upon request

Page 7: INDUSTRIAL GRADE - Nexans

350 Bailey Road • El Dorado, Arkansas USA • www.AmerCable.nexans.com • e-mail: [email protected]

TYPE W 2/C

SIZE AWG

8 6 4 2 1

1/0 2/0 3/0 4/0 250 350 500

NO. OF

WIRES PER CONDUCTOR

133 133 259 259 259 266 323 418 532 627 888

1221

INSULATION THICKNESS

MILS

60 60 60 60 80 80 80 80 80 95 95 95

NOMINAL OUTSIDE

DIMENSIONS IN.

.831

.904 1.028 1.222 1.419 1.509 1.605 1.749 1.901 2.004 2.300 2.620

APPROX. WEIGHT LBS. PER 1,000 FT.

362 459 624 941

1245 1443 1682 2059 2471 2830 3839 5158

37-430-

008BC 006BC 004BC 002BC 001BC 010BC 020BC 030BC 040BC 250BC 350BC 500BC

POWER CONDUCTORS AMPACITY* 30°C

AMBIENT TEMP

74 99

130 174 202 234 271 313 361 402 495 613

1 Jacket – Black Heavy-Duty (HD) CPE is standard. Colored HD CPE jackets available upon request. *Ampacity – Based on continuous duty at 90°C conductor temperature, with not more than three current carrying conductors.

TYPE W 3/C

SIZE AWG

8 6 4 2 1

1/0 2/0 3/0 4/0 250 350 500

NO. OF

WIRES PER CONDUCTOR

133 133 259 259 259 266 323 418 532 627 888

1221

INSULATION THICKNESS

MILS

60 60 60 60 80 80 80 80 80 95 95 95

NOMINAL OUTSIDE

DIMENSIONS IN.

.942 1.020 1.121 1.292 1.470 1.609 1.702 1.857 2.020 2.310 2.580 2.936

APPROX. WEIGHT LBS. PER 1,000 FT.

516 644 843

1225 1545 1881 2172 2669 3195 4049 5334 7218

37-431-

008BC 006BC 004BC 002BC 001BC 010BC 020BC 030BC 040BC 250BC 350BC 500BC

POWER CONDUCTORS AMPACITY* 30°C

AMBIENT TEMP

65 87

114 152 177 205 237 274 316 352 433 536

*Ampacity – Based on continuous duty at 90°C conductor temperature, with not more than two current carrying conductors.

Page 8: INDUSTRIAL GRADE - Nexans

Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613

37-432/33

TYPE W 4-5/C PORTABLE POWER•EASY-STRIP JACKET 2000 VOLTS

FEATURES � Highly durable, abrasion-resistant CPE jacket specially designed

and cured for easy stripping � Outstanding Nexans AmerCable engineering support

APPLICATION Manufactured for heavy-duty or temporary power supply service, AC or DC, to motor or generator, portable and stationary heavy-duty equipment, cranes, conveyors and other mobile equipment applications. Nexans AmerCable INDUSTRIAL Type W features a reinforced jacket that is specially designed and cured for easy stripping and cable preparation.

Recommended maximum continuous conductor temperature is 90°C. Suitable for installation in air, ducts, shallow water or direct burial.

Cable carries MSHA marking indicating listing by the Mine Safety and Health Administration and the Pennsylvania Department of Environmental Protection.

Nexans AmerCable INDUSTRIAL GRADE cable meets or exceeds the material requirements of ICEA Standards S-75-381/NEMA WC-58.

RATINGS & APPROVALS � Mine Safety & Health Administration (MSHA) � Pennsylvania Department of Environmental Protection � UL listed Type W meeting requirements of UL 1650

and UL portable power cable file E97865

INSULATION 90°C ethylene-propylene rubber (EPR)

JACKET1 Black thermosetting Chlorinated Polyethylene (CPE) Jacket cured for easy stripping and cable preparation. Cable identification via permanent marking: AMERCABLE (UL) TYPE W [SIZE] #/C 90C WET OR DRY 2000V SUN RES OIL RESISTANT 60C -40C FT5 [MSHA]

CONDUCTORS Bare copper

SEPARATOR For easy stripping of insulation

Specially Designed &

Cured CPE Jacket for Easier, Faster

Stripping!

________

CSA constructions

available upon request

Page 9: INDUSTRIAL GRADE - Nexans

350 Bailey Road • El Dorado, Arkansas USA • www.AmerCable.nexans.com • e-mail: [email protected]

TYPE W 4/C

SIZE AWG

8 6 4 2 1

1/0 2/0 3/0 4/0 250 350 500

NO. OF

WIRES PER CONDUCTOR

133 133 259 259 259 266 323 418 532 627 888

1221

INSULATION THICKNESS

MILS

60 60 60 60 80 80 80 80 80 95 95 95

NOMINAL OUTSIDE

DIMENSIONS IN.

1.020 1.105 1.221 1.380 1.609 1.765 1.868 2.038 2.185 2.660 2.955 3.400

APPROX. WEIGHT LBS. PER 1,000 FT.

617 795

1010 1501 1949 2363 2795 3350 4048 5420 7305 9682

37-432-

008BC 006BC 004BC 002BC 001BC 010BC 020BC 030BC 040BC 250BC 350BC 500BC

POWER CONDUCTORS AMPACITY* 30°C

AMBIENT TEMP

65 87

114 152 177 205 237 274 316 352 433 536

TYPE W 5/C

1 Jacket – Black Heavy-Duty (HD) CPE is standard. Colored HD CPE jackets available upon request. *Ampacity – Based on continuous duty at 90°C conductor temperature, with not more than three current carrying conductors.

SIZE AWG

8 6 4 2 1

1/0 2/0 3/0 4/0

NO. OF

WIRES PER CONDUCTOR

133 133 259 259 259 266 323 418 532

INSULATION THICKNESS

MILS

60 60 60 60 80 80 80 80 80

NOMINAL OUTSIDE

DIMENSIONS IN.

1.068 1.204 1.400 1.614 1.895 2.029 2.145 2.340 2.535

APPROX. WEIGHT LBS. PER 1,000 FT.

690 999

1377 1975 2679 3038 3569 4325 5287

37-433-

008BC 006BC 004BC 002BC 001BC 010BC 020BC 030BC 040BC

POWER CONDUCTORS AMPACITY* 30°C

AMBIENT TEMP

65 87

114 152 177 205 237 274 316

Page 10: INDUSTRIAL GRADE - Nexans

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING POWER CABLES

Nexans AmerCable 350 Bailey Road • El Dorado, AR USA 800-643-1516 • 870-862-4919 • Fax: 870-862-8659 email: [email protected] www.AmerCable.nexans.com © 2020, AmerCable Incorporated 9_20

Nexans AmerCable is an ISO 9001 certified cable manufacturer that combines leading-edge manufacturing technology, innovative thinking, and high quality service to deliver the finest industrial cable products available.

Our professional engineers and sales force work with you to create innovative, cost effective project solutions.

FOLLOW US!