Granit™ 1280i Industrial Full Range Laser Scanner User’s Guide

Transcript of Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15...

Page 1: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Granit™ 1280i

Industrial Full Range Laser Scanner

User’s Guide

Page 2: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

DisclaimerHoneywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.

HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.

This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII.

2014 Honeywell International Inc. All rights reserved.

Web Address: www.honeywellaidc.com

Granit is a trademark or registered trademark of Honeywell International Inc.

Microsoft® Windows®, Windows NT®, Windows 2000, Windows ME, Windows XP, and the Windows logo are trademarks or registered trademarks of Microsoft Corporation.

Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners.

Page 3: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Product Agency Compliance - Granit 1280i

USA

FCC Part 15 Subpart B Class BThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential instal-lation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accor-dance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the inter-ference by one or more of the following measures:

• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio or television technician for help.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Honeywell is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Honeywell. The correction is the responsibility of the user.

Use only shielded data cables with this system. This unit has been tested with cables less than 3 meters. Cables greater than 3 meters may not meet class B performance.

Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC authorization to operate this equipment.

TÜV-R StatementTÜV R listed: UL 60950-1, Second Edition and CSA C22.2 No.60950-1-07, Second Edition.

Canada

Industry Canada ICES-003This Class B digital apparatus complies with Canadian ICES-003. Operation is subject to the following conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that may cause undesired operation.

Conformité à la règlementation canadienneCet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada. Son fonctionnement est assujetti aux conditions suivantes :

1. Cet appareil ne doit pas causer de brouillage préjudiciable.

2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le brouillage pouvant causer un fonctionnement indésirable.

TÜV-R StatementTÜV R listed: UL 60950-1, Second Edition and CSA C22.2 No.60950-1-07, Second Edition.

TÜV Rheinland

C US

TÜV Rheinland

C US

Page 4: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EuropeThe CE marking indicates compliance with the following directives:

• 2004/108/EC EMC• 2011/65/EU RoHS (Recast)

In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply. European contact:

Hand Held Products Europe B.V.Nijverheidsweg 9-135627 BT EindhovenThe Netherlands

Honeywell International Inc. shall not be liable for use of our product with equipment (i.e., power supplies, personal comput-ers, etc.) that is not CE marked and does not comply with the Low Voltage Directive.

Honeywell Scanning & Mobility Product Environmental InformationRefer to www.honeywellaidc.com/environmental for the RoHS / REACH / WEEE information.

Australia/NZ

C-Tick Statement

Conforms to AS/NZS 3548 EMC requirement

Mexico

Conforms to NOM-019.

Japan

VCCI: V-3, Technical Requirements, Class B ITE.

この装置は、 クラス B 情報技術装置です。 この装置は、 家庭環境で使用

することを目的としていますが、 この装置がラジオやテレビジ ョ ン受信機に

近接して使用されると、 受信障害を引き起こすことがあります。

取扱説明書に従って正しい取り扱いをして下さい。 VCCI–B

South KoreaThis product meets Korean agency approval.

TaiwanIf the following label is attached to your product, the product meets Taiwan agency approval:

BSMI Standard: CNS13438, CNS14336

依據標準 : CNS13438, CNS14336

Page 5: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

RussiaCustoms Union approval

International

CB SchemeCertified to CB Scheme IEC 60950-1, Second Edition.

Laser Safety StatementIf the following label is attached to your product, it indicates the product contains a laser engine or laser aimer:

This device has been tested in accordance with and complies with IEC60825-1 ed2 (2007). Complies with 21 CFR 1040.10 and 1040.11, except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.

LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PRODUCT, 1.0 mW MAX OUTPUT: 650nM.

Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

PatentsFor patent information, please refer to www.honeywellaidc.com/patents.

Solids and Water ProtectionThe Granit 1280i has a rating of IP65, totally protected against dust and protected against low pressure water jets.

WarningTo reduce the possibility of heat-related injuries, avoid touching sections of the scanner that feel warm.

LASER LIGHT - DO NOT STARE INTO BEAM. CLASS 2 LASER PRODUCT.RAYONNEMENT LASER NE PAS REGARDER DANS LE FAISCEAU. APPAREIL ÀLASER DE CLASSE 2. MAX. 1mW :630-680 nm. IEC 60825-1: 2007. Complies with21 CFR 1040.10 and 1040.11 except for deviations pursuant To Laser Notice No. 50,dated June 24, 2007.

!

Page 6: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Required Safety Labels

Granit 1280i Scanner

Laser Label location

Part Number, Serial Number and Revision Information location

Compliance label location

Page 7: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Table of Contents

Chapter 1 - Getting Started

About This Manual ...............................................................................................................1-1Unpacking Your Device .......................................................................................................1-1Connecting the Device.........................................................................................................1-1Reading Techniques ............................................................................................................1-2Cyber Security Settings .......................................................................................................1-2Setting Custom Defaults ......................................................................................................1-2Resetting the Custom Defaults ............................................................................................1-2

Chapter 2 - Programming the Interface

Introduction ..........................................................................................................................2-1Programming the Interface - Plug and Play .........................................................................2-1RS232 Serial Port ................................................................................................................2-1

OPOS Mode...................................................................................................................2-1Verifone® Ruby Terminal Default Settings...........................................................................2-2Gilbarco® Terminal Default Settings ....................................................................................2-2Honeywell Bioptic Aux Port Configuration ...........................................................................2-2Datalogic™ Magellan® Aux Port Configuration....................................................................2-2NCR Bioptic Aux Port Configuration ....................................................................................2-3Wincor Nixdorf Terminal Default Settings ............................................................................2-3Wincor Nixdorf Beetle™ Terminal Default Settings .............................................................2-3RS232 Modifiers ..................................................................................................................2-4

RS232 Baud Rate ..........................................................................................................2-4RS232 Word Length: Data Bits, Stop Bits, and Parity ...................................................2-5RS232 Handshaking ......................................................................................................2-6RS232 Timeout ..............................................................................................................2-7XON/XOFF.....................................................................................................................2-7ACK/NAK .......................................................................................................................2-8Communication Timeout ................................................................................................2-8NAK Retries ...................................................................................................................2-9Support BEL/CAN in ACK/NAK......................................................................................2-9RS232 Defaults ..............................................................................................................2-9

NCR Modifiers......................................................................................................................2-9NCR ACK/NAK...............................................................................................................2-9Block Check Character ................................................................................................2-10NCR Prefix ...................................................................................................................2-10NCR Suffix ...................................................................................................................2-10NCR Prefix/Suffix .........................................................................................................2-10NCR NOF (Not-on-File) Error.......................................................................................2-11

Scanner to Bioptic Communication....................................................................................2-11Scanner-Bioptic Packet Mode......................................................................................2-11

Chapter 3 - Input/Output Settings

Power Save Mode................................................................................................................3-1Power Up Beeper.................................................................................................................3-1

i

Page 8: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Beep on BEL Character....................................................................................................... 3-2Good Read and Error Indicators.......................................................................................... 3-2

Beeper – Good Read..................................................................................................... 3-2Beeper Volume – Good Read........................................................................................ 3-2Beeper Pitch – Good Read............................................................................................ 3-3Beeper - Transmit Order................................................................................................ 3-3Vibrate – Good Read..................................................................................................... 3-3Beeper Pitch – Error ...................................................................................................... 3-4Beeper Duration – Good Read ...................................................................................... 3-4Number of Beeps – Good Read .................................................................................... 3-5Number of Beeps – Error............................................................................................... 3-5Beeper Volume Max ...................................................................................................... 3-5

Laser Aimer ......................................................................................................................... 3-5Laser Aimer - Scanning Pattern..................................................................................... 3-5Laser Aimer - Scanning Duration................................................................................... 3-6Laser Aimer - Good Read Pattern ................................................................................. 3-6Laser Aimer - Good Read Duration ............................................................................... 3-7Aimer Delay ................................................................................................................... 3-7

LED Indicators ..................................................................................................................... 3-8LED Settings.................................................................................................................. 3-8Good Read Delay .......................................................................................................... 3-9User-Specified Good Read Delay.................................................................................. 3-9

Out-Of-Stand Settings ......................................................................................................... 3-9Out-of-Stand Defaults .................................................................................................... 3-9Presentation Mode....................................................................................................... 3-10Manual Activation Mode .............................................................................................. 3-10End Manual Activation After Good Read..................................................................... 3-10Manual Activation Laser Timeout - Trigger Settings.................................................... 3-11

Reread Delay..................................................................................................................... 3-11User-Specified Reread Delay ...................................................................................... 3-11

CodeGate® ........................................................................................................................ 3-12Character Activation Mode ................................................................................................ 3-12

Activation Character .................................................................................................... 3-12End Character Activation After Good Read................................................................. 3-13Character Activation Timeout ...................................................................................... 3-13

Character Deactivation Mode ............................................................................................ 3-13Deactivation Character ................................................................................................ 3-14

Centering ........................................................................................................................... 3-14Blinky Mode ....................................................................................................................... 3-15Laser Scan Angle .............................................................................................................. 3-15Decode Security ................................................................................................................ 3-16Continuous Scan Mode ..................................................................................................... 3-16

ii

Page 9: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Output Sequence Overview............................................................................................... 3-16Output Sequence Editor .............................................................................................. 3-16To Add an Output Sequence ....................................................................................... 3-16Other Programming Selections.................................................................................... 3-17Output Sequence Editor .............................................................................................. 3-18Sequence Timeout....................................................................................................... 3-18Sequence Match Beeper ............................................................................................. 3-18Partial Sequence ......................................................................................................... 3-19Require Output Sequence ........................................................................................... 3-19

No Read ............................................................................................................................ 3-20

Chapter 4 - Data Editing

Prefix/Suffix Overview ......................................................................................................... 4-1To Add a Prefix or Suffix:............................................................................................... 4-1To Clear One or All Prefixes or Suffixes ........................................................................ 4-2To Add a Carriage Return Suffix to All Symbologies ..................................................... 4-2

Prefix Selections.................................................................................................................. 4-2Suffix Selections .................................................................................................................. 4-2Function Code Transmit ...................................................................................................... 4-3Communication Check Character........................................................................................ 4-3Intercharacter, Interfunction, and Intermessage Delays...................................................... 4-3

Intercharacter Delay ...................................................................................................... 4-4User Specified Intercharacter Delay .............................................................................. 4-4Interfunction Delay......................................................................................................... 4-4Intermessage Delay....................................................................................................... 4-5

Chapter 5 - Data Formatting

Data Format Editor Introduction .......................................................................................... 5-1Add a Data Format .............................................................................................................. 5-1

Other Programming Selections...................................................................................... 5-2Terminal ID Table ................................................................................................................ 5-3Data Format Editor Commands........................................................................................... 5-3

Move Commands........................................................................................................... 5-6Search Commands........................................................................................................ 5-7Miscellaneous Commands............................................................................................. 5-9

Data Formatter .................................................................................................................. 5-11Data Format Non-Match Error Tone............................................................................ 5-12

Primary/Alternate Data Formats ........................................................................................ 5-12Single Scan Data Format Change............................................................................... 5-13

Chapter 6 - Symbologies

All Symbologies ................................................................................................................... 6-1Message Length Description ............................................................................................... 6-1Codabar............................................................................................................................... 6-2

Codabar Concatenation................................................................................................. 6-3

iii

Page 10: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 39 ............................................................................................................................... 6-5Code 32 Pharmaceutical (PARAF) ................................................................................ 6-6Full ASCII....................................................................................................................... 6-7Code 39 Code Page ...................................................................................................... 6-7

Interleaved 2 of 5................................................................................................................. 6-8Matrix 2 of 5......................................................................................................................... 6-9NEC 2 of 5 ......................................................................................................................... 6-11Code 93 ............................................................................................................................. 6-12

Code 93 Code Page .................................................................................................... 6-13Straight 2 of 5 Industrial (three-bar start/stop)................................................................... 6-14Straight 2 of 5 IATA (two-bar start/stop) ............................................................................ 6-15Code 11 ............................................................................................................................. 6-16Code 128 ........................................................................................................................... 6-17

ISBT 128 Concatenation.............................................................................................. 6-18GS1-128 ............................................................................................................................ 6-23Telepen.............................................................................................................................. 6-24UPC-A ............................................................................................................................... 6-25UPC-A/EAN-13

with Extended Coupon Code .......................................................................................... 6-28UPC-A/Code 128 Coupon Code Output ...................................................................... 6-28UPC-A Number System 5 Addenda Required............................................................. 6-29Coupon GS1 DataBar Output ...................................................................................... 6-30

UPC-E0 ............................................................................................................................. 6-31EAN/JAN-13 ...................................................................................................................... 6-34

Convert UPC-A to EAN-13 .......................................................................................... 6-34ISBN Translate ............................................................................................................ 6-40ISSN Translate ............................................................................................................ 6-41

EAN/JAN-8 ........................................................................................................................ 6-42MSI .................................................................................................................................... 6-44Plessey Code .................................................................................................................... 6-46GS1 DataBar Omnidirectional ........................................................................................... 6-47GS1 DataBar Limited......................................................................................................... 6-48GS1 DataBar Expanded .................................................................................................... 6-49Trioptic Code ..................................................................................................................... 6-50GS1 Emulation .................................................................................................................. 6-50China Post (Hong Kong 2 of 5).......................................................................................... 6-51

Chapter 7 - Utilities

To Add a Test Code I.D. Prefix to All Symbologies ............................................................. 7-1Show Software Revision...................................................................................................... 7-1Show Data Format............................................................................................................... 7-1Test Menu............................................................................................................................ 7-1TotalFreedom ...................................................................................................................... 7-1Application Plug-Ins (Apps) ................................................................................................. 7-2EZConfig-Scanning Introduction.......................................................................................... 7-2

Installing EZConfig-Scanning from the Web.................................................................. 7-3Resetting the Factory Defaults ............................................................................................ 7-3

iv

Page 11: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Chapter 8 - Serial Programming Commands

Conventions......................................................................................................................... 8-1Menu Command Syntax ...................................................................................................... 8-1Query Commands ............................................................................................................... 8-1

Responses..................................................................................................................... 8-2Serial Trigger Commands.................................................................................................... 8-3

Read Time-Out .............................................................................................................. 8-3Resetting the Custom Defaults............................................................................................ 8-3Menu Commands ................................................................................................................ 8-4

Chapter 9 - Product Specifications

Granit 1280i Industrial Corded Scanner Product Specifications.......................................... 9-1Depth of Field Charts........................................................................................................... 9-2

Typical Performance ..................................................................................................... 9-2Guaranteed Performance ............................................................................................ 9-2....................................................................................................................................... 9-3

Standard Connector Pinouts ............................................................................................... 9-4Serial Output.................................................................................................................. 9-4

Chapter 10 - Maintenance

Repairs .............................................................................................................................. 10-1Maintenance ...................................................................................................................... 10-1

Cleaning the Scanner .................................................................................................. 10-1Cleaning the Window................................................................................................... 10-1Inspecting Cords and Connectors ............................................................................... 10-1

Replacing Cables .............................................................................................................. 10-1Replacing an Interface Cable ...................................................................................... 10-2

Troubleshooting................................................................................................................. 10-2

Chapter 11 - Customer Support

Technical Assistance......................................................................................................... 11-1Product Service and Repair............................................................................................... 11-1

Appendix A - Reference Charts

Symbology Charts ...............................................................................................................A-1Linear Symbologies .......................................................................................................A-1Postal Symbologies .......................................................................................................A-2

ASCII Conversion Chart (Code Page 1252)........................................................................A-2Lower ASCII Reference Table.............................................................................................A-3ISO 2022/ISO 646 Character Replacements ......................................................................A-7Unicode Key Maps ..............................................................................................................A-9

v

Page 12: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

vi

Page 13: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

1

Getting Started

About This ManualThis User’s Guide provides installation and programming instructions for the Granit 1280i corded industrial scanners. Product specifications, dimensions, warranty, and customer support information are also included.

Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.

An asterisk (*) next to an option indicates the default setting.

Unpacking Your DeviceAfter you open the shipping carton containing the product, take the following steps:

• Check for damage during shipment. Report damage immediately to the carrier who delivered the carton.• Make sure the items in the carton match your order.• Save the shipping container for later storage or shipping.

Connecting the Device1. Turn off power to the terminal/computer.

2. Connect the appropriate interface cable to the scanner.

Note: For the scanner to work properly, you must have the correct cable for your type of terminal/computer.

3. Make sure the cable is pushed tightly into the scanner. Loosen the locking plate and slide it over the base of the cable connector to lock the cable in place. Tighten the screw.

4. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port.

5. Once the scanner has been fully connected, power up the computer.

6. Plug in the AC adapter, if applicable.

This interface programs 9600 baud, 8 data bits, no parity, and 1 stop bit.

1 - 1

Page 14: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Reading TechniquesThe Granit 1280i scanner has a bright red scanning line that corresponds to the scanner’s horizontal field of view.

The scanning line is smaller when the scanner is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. To read single or multiple symbols (on a page or on an object), hold the scanner at an appropriate distance from the target, pull the trigger, and center the scanning line on the symbol. If the code being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the code up 15° to 18° to prevent unwanted reflection.

Cyber Security SettingsHoneywell scanners have additional settings aimed at preventing cyber attacks. You may want to restrict the ability to program your device with menu codes or serial commands, or you may want to disable firmware upgrades to your device. Honeywell’s Cyber Security settings allow you to secure your device by restricting these features. Please contact the nearest technical sup-port office (see Technical Assistance on page 11-1) for further information.

Setting Custom DefaultsYou have the ability to create a set of menu commands as your own, custom defaults. To do so, scan the Set Custom Defaults bar code below before scanning the menu commands for your custom defaults. If a menu command requires scanning numeric codes from the back cover, then a Save code, that entire sequence will be saved to your custom defaults. When you have entered all the commands you want to save for your custom defaults, scan the Save Custom Defaults bar code.

You may have a series of custom settings and want to correct a single setting. To do so, just scan the new setting to overwrite the old one. For example, if you had previously saved the setting for Beeper Volume at Low to your custom defaults, and decide you want the beeper volume set to High, just scan the Set Custom Defaults bar code, then scan the Beeper Volume High menu code, and then Save Custom Defaults. The rest of the custom defaults will remain, but the beeper volume setting will be updated.

Resetting the Custom DefaultsIf you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This is the recommended default bar code for most users. It resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings.

Set Custom Defaults

Save Custom Defaults

Activate Custom Defaults

1 - 2

Page 15: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

2

Programming the Interface

IntroductionThis chapter describes how to program your system for the desired interface.

Programming the Interface - Plug and PlayPlug and Play bar codes provide instant scanner set up for commonly used interfaces.

Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.

RS232 Serial PortThe RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated below. It also

changes the trigger mode to manual.

OPOS ModeThe following bar code configures your engine for OPOS (OLE for Retail Point of Sale) by modifying the following OPOS-related settings:

Option Setting

Baud Rate 9600 bpsData Format 8 data bits, no parity bit, 1 stop bit

Option Setting

Interface RS232Baud Rate 38400RS232 Handshaking Flow Control, No Timeout

XON/XOFF OffACK/NAK Off

Data Bits, Stop Bits, and Parity 8 Data, 1 Stop, Parity NonePrefix/Suffix

Clear All Prefixes and SuffixesAdd Code ID and AIM ID PrefixAdd CR Suffix

Intercharacter Delay OffSymbologies Enable UPC-A with check digit and number system

Enable UPC-E0 with check digitEnable EAN/JAN-8 with check digitEnable EAN/JAN-13 with check digitEnable Code 128Enable Code 39Enable OPOS with automatic disable off

RS232 Interface

OPOS Mode

2 - 1

Page 16: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Verifone® Ruby Terminal Default SettingsScan the following Plug and Play code to program the scanner for a Verifone Ruby terminal. This bar code sets the baud rate to 1200 bps and the data format to 8 data bits, no parity bit, 1 stop bit. It also adds a line feed (LF) suffix and programs the follow-ing prefixes for each symbology:

Gilbarco® Terminal Default SettingsScan the following Plug and Play code to program the scanner for a Gilbarco terminal. This bar code sets the baud rate to 2400 bps and the data format to 7 data bits, even parity, 2 stop bits. It also adds a carriage return (CR) suffix and programs the follow-ing prefixes for each symbology:

Honeywell Bioptic Aux Port ConfigurationScan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit.

Datalogic™ Magellan® Aux Port ConfigurationScan the following Plug and Play code to program the scanner for a Datalogic Magellan auxiliary port configuration. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit.

Symbology Prefix

UPC-A AUPC-E AEAN-8 FFEAN-13 F

Symbology Prefix

UPC-A AUPC-E E0EAN-8 FFEAN-13 F

Verifone Ruby Settings

Gilbarco Settings

Honeywell Bioptic Settings

Datalogic Magellan Settings

2 - 2

Page 17: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

NCR Bioptic Aux Port ConfigurationScan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration. The fol-lowing prefixes are programmed for each symbology:

Wincor Nixdorf Terminal Default SettingsScan the following Plug and Play code to program the scanner for a Wincor Nixdorf terminal. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit.

Wincor Nixdorf Beetle™ Terminal Default SettingsScan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal. The following prefixes are programmed for each symbology:

Symbology Prefix Symbology Prefix

UPC-A A Code 39 aUPC-E E0 Code 128 fEAN-8 FF Interleaved 2 of 5 bEAN-13 F All other bar

codesB3

Symbology Prefix Symbology Prefix

Code 128 K EAN-13 ACode 93 L GS1-128 PCodabar N Interleaved 2 of 5 IUPC-A A0 Plessey OUPC-E C Straight 2 of 5 IATA HEAN-8 B All other bar codes M

NCR Bioptic Settings

Wincor Nixdorf Terminal Settings

Wincor Nixdorf Beetle Settings

2 - 3

Page 18: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

RS232 Modifiers

RS232 Baud RateBaud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the

same baud rate as the scanner. Default = 9600.

300

600

1200

2400

4800

* 9600

19200

38400

57,600

115,200

2 - 4

Page 19: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

RS232 Word Length: Data Bits, Stop Bits, and ParityData Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications that require use of the full ASCII set, select 8 data bits per character. Default = 8.

Stop Bits sets the stop bits at 1 or 2. Default = 1.

Parity provides a means of checking character bit patterns for validity.Default = None.

7 Data, 1 Stop, Parity Even

7 Data, 1 Stop, Parity None

7 Data, 1 Stop, Parity Odd

7 Data, 2 Stop, Parity Even

7 Data, 2 Stop Parity None

7 Data, 2 Stop, Parity Odd

8 Data, 1 Stop, Parity Even

* 8 Data, 1 Stop, Parity None

8 Data, 1 Stop, Parity Odd

7 Data, 1 Stop, Parity Space

2 - 5

Page 20: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

RS232 HandshakingRS232 Handshaking allows control of data transmission from the scanner using software commands from the host device.

RTS/CTS Off: RTS/CTS is turned off so no data flow control is used, but RTS is still active.

RTS/CTS Off, RTS Inactive: RTS/CTS is turned off so no data flow control is used and RTS is inactive.

Flow Control, No Timeout: The scanner asserts RTS when it has data to send, and will wait indefinitely for CTS to be asserted by the host.

Character-Based Flow Control, No Timeout: The scanner asserts RTS when it has a character to send, and will wait indefinitely for CTS to be asserted by the host

Two-Direction Flow Control: The scanner asserts RTS when it is OK for the host to transmit. The host asserts CTS when it is OK for the device to transmit.

Flow Control with Timeout: The scanner asserts RTS when it has data to send and waits for a delay (see RS232 Timeout on page 2-7) for CTS to be asserted by the host. If the delay time expires and CTS is not asserted, the device transmit buffer is cleared and scanning may resume.

Character-Based Flow Control with Timeout: The scanner asserts RTS when it has a character to send and waits for a delay (see RS232 Timeout on page 2-7) for CTS to be asserted by the host. If the delay time expires and CTS is not asserted, the device transmit buffer is cleared and scanning may resume.Default = RTS/CTS Off.

7 Data, 2 Stop, Parity Space

8 Data, 1 Stop, Parity Space

7 Data, 1 Stop, Parity Mark

7 Data, 2 Stop, Parity Mark

8 Data, 1 Stop, Parity Mark

* RTS/CTS Off

* RTS/CTS Off, RTS Inactive

2 - 6

Page 21: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

RS232 TimeoutWhen using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from 1-65535 milli-seconds) by scanning digits from the inside back cover, then scanning Save.

XON/XOFFStandard ASCII control characters can be used to tell the scanner to start sending data (XON/XOFF On) or to stop sending data (XON/XOFF Off). When the host sends the XOFF character (DC3, hex 13) to the scanner, data transmission stops. To resume transmission, the host sends the XON character (DC1, hex 11). Data transmission continues where it left off

when XOFF was sent. Default = XON/XOFF Off.

Flow Control, No Timeout

Character-Based Flow Control, No Timeout

Two-Direction Flow Control

Flow Control with Timeout

Character-Based Flow Control with Timeout

RS232 Timeout

XON/XOFF On

* XON/XOFF Off

2 - 7

Page 22: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ACK/NAKAfter transmitting data, the scanner waits for an ACK character (hex 06) or a NAK character (hex 15) response from the host. If ACK is received, the communications cycle is completed and the scanner looks for more bar codes. If NAK is received, the last set of bar code data is retransmitted and the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by scanning the ACK/NAK On bar code below. To turn off the protocol, scan ACK/NAK Off. Default = ACK/NAK

Off.

Communication TimeoutThis allows you to set the length (in milliseconds) for a timeout for the host ACK/NAK response. Scan the bar code below, then set the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 2000 ms.

Timeout RetriesThis setting limits the number of Communication Timeout retries. If the Timeout Retries is set to 0, the transmission is terminated after the initial Communication Timeout. Scan the bar code below, then set the number of retries (from 0-255) by scanning digits from the Programming Chart, then scanning Save. (5 is the recommended setting.) Default = 0.

Communication Timeout BeeperThis selection programs the scanner to issue an error beep when a communication timeout has occurred. The error beep sound is programmed using Number of Beeps – Error (page 3-5). Default = On.

ACK/NAK On

* ACK/NAK Off

Communication Timeout

Timeout Retries

Off

* On

2 - 8

Page 23: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

NAK RetriesThis selection limits the number of NAK retries that can occur in ACK/NAK mode. Scan the bar code below, then set the number of retries (from 0-255) by scanning digits from the Programming Chart, then scanning Save. (5 is the recom-mended setting.) Default = 0, or disabled.

Support BEL/CAN in ACK/NAKThis protocol responds to <BEL> and <CAN> commands when in ACK/NAK mode. The scanner sounds an error tone

when a <BEL> command is sent from the host. <CAN> terminates the transmission. Default = BEL/CAN Off.

RS232 DefaultsIf you want the custom RS232 default settings restored to your scanner, scan the RS232 Defaults bar code below. This resets the scanner to the custom default settings (see Setting Custom Defaults on page 1-2). If there are no custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the cus-tom defaults will be restored to the factory default settings.

NCR Modifiers

NCR ACK/NAK

This is an NCR communication protocol for ACK/NAK processing. Default = NCR ACK/NAK Off.

NAK Retries

BEL/CAN On

* BEL/CAN Off

RS232 Defaults

* NCR ACK/NAK Off

NCR ACK/NAK On

2 - 9

Page 24: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Block Check CharacterWhen this selection is set to Transmit, the NCR Block Check Character (BCC) is expected with incoming messages and

transmitted with outgoing messages. Default = Transmit.

NCR PrefixThis selection allows you to program an NCR-specific prefix. Refer to the ASCII Conversion Chart (Code Page 1252), page A-2 to find the hex equivalent for the characters you want for the NCR prefix (typically, 02 for STX). Scan the bar code below, then set the hex number (from 0-FF) by scanning digits from the Programming Chart, then scanning Save. Default = 0.

NCR SuffixThis selection allows you to program an NCR-specific suffix. Refer to the ASCII Conversion Chart (Code Page 1252), page A-2 to find the hex equivalent for the characters you want for the NCR suffix (typically, 03 for ETX). Scan the bar code below, then set the hex number (from 0-FF) by scanning digits from the Programming Chart, then scanning Save. Default = 0.

NCR Prefix/SuffixWhen set to Transmit, both the NCR prefix and suffix are transmitted with bar codes. Usually, prefixes and suffixes are programmed using the Data Editing selections (see Data Editing beginning on page 4-1), however, the following commands override any other prefix/suffix settings. Default = Don’t Transmit.

* Transmit

Don’t Transmit

NCR Prefix

NCR Suffix

Transmit

* Don’t Transmit

2 - 10

Page 25: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

NCR NOF (Not-on-File) ErrorA scanner receives an NOF (Not on File) command from the POS whenever it cannot cross-reference the bar code to a price parameter. When set to On, the error tone sounds (set via Number of Beeps – Error, page 3-5) for an NOF, and dis-ables the scanner while the cashier looks up the price manually. When set to Off, no sound is emitted for an NOF. Default

= Off.

Scanner to Bioptic CommunicationThe following settings are used to set up communication between Honeywell scanners and bioptic scanners.

Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner. See "RS232 Modifiers" on page 2-4, and RS232 Timeout on page 2-7 for further information.

Scanner-Bioptic Packet ModePacket Mode On must be scanned to set the scanner’s format so it is compatible with a bioptic scanner. Default = Packet

Mode Off.

On

* Off

* Packet Mode Off

Packet Mode On

2 - 11

Page 26: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

2 - 12

Page 27: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

3

Input/Output Settings

Power Save ModePower Save Mode allows you to automatically set the conditions under which the scanner idles, sleeps, and wakes up. When Off is selected, no power saving is used and the scanner remains powered on until the trigger is pressed.

When Sleep Mode is selected, the scanner goes into sleep mode (powered off) after the time interval set using Power Save Mode Timeout (page 3-1), during which there is no activity. This provides significant power savings over the Off setting.

When Hibernate Mode is selected, the scanner goes into idle mode after the time interval set using Power Save Mode Timeout (page 3-1), during which there is no activity. After the same time interval has elapsed with no activity while the scanner is in idle mode, the scanner goes into sleep mode (powered off). This provides additional power savings over the Sleep Mode setting, but the scanner takes longer to wake up.

Default = Off.

Power Save Mode TimeoutUse this selection to set a timeout (in seconds) for the scanner when using Power Save Mode. When this time has elapsed with no activity, the scanner will enter the Power Save Mode selected. After scanning the Power Save Mode Timeout bar code, set the timeout duration (from 0-65535 seconds) by scanning digits on the Programming Chart inside the back cover, then scanning Save. Default = 600 seconds.

Power Up BeeperThe scanner can be programmed to beep when it’s powered up. Scan the Off bar code(s) if you don’t want a power up beep.

Default = Power Up Beeper On - Scanner.

* Off

Sleep Mode Only

Hibernate Mode

Power Save Mode Timeout

Power Up Beeper Off - Scanner

3 - 1

Page 28: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Beep on BEL CharacterYou may wish to force the scanner to beep upon a command sent from the host. If you scan the Beep on BEL On bar code

below, the scanner will beep every time a BEL character is received from the host. Default = Beep on BEL Off.

Good Read and Error Indicators

Beeper – Good ReadThe beeper may be programmed On or Off in response to a good read. Turning this option off only turns off the beeper

response to a good read indication. All error and menu beeps are still audible. Default = Beeper - Good Read On.

Beeper Volume – Good Read

The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High.

* Power Up Beeper On - Scanner

*Beep on BEL Off

Beep on BEL On

Beeper - Good Read Off

* Beeper - Good Read On

Low

Medium

* High

3 - 2

Page 29: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Beeper Pitch – Good Read

The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium.

Beeper - Transmit OrderThe beeper transmit order determines when the good read beep occurs. The scanner can be set to emit the good read

beep either before or after data transmission. Default = Before Transmission.

Vibrate – Good ReadThe scanner vibrates once when a bar code is successfully read, and twice when a programming bar code is successfully read. When a programming bar code is unsuccessful, the scanner emits one long vibration (2 times the Vibrate Duration length). The trigger cannot be used again until the vibration has ended. Scan Vibrate - Good Read Off to keep the scan-ner from vibrating. This setting may be preferable if you need to scan multiple bar codes in succession and do not want to wait till the vibration has ended. Default = Vibrate - Good Read On.

Off

Low (1600 Hz)

* Medium (3200 Hz)

High (4200 Hz)

* Before Transmission

After Transmission

Vibrate- Good Read Off

* Vibrate- Good Read On

3 - 3

Page 30: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Vibrate DurationIf you want to set the length for the good read vibration, scan the bar code below, then set the duration (from 100 - 2,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. If you need to scan multiple bar codes in succession, you may wish to set a short duration time, since the trigger cannot be used until the vibration has ended. Default = 300 ms.

Beeper Pitch – ErrorThe beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = Razz.

Beeper Duration – Good Read

The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal.

Vibrate Duration

* Razz (100 Hz)

Medium (3250 Hz)

High (4200 Hz)

* Normal Beep

Short BeepShort Beep

3 - 4

Page 31: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Number of Beeps – Good ReadThe number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read. The beeps and LED flashes are in sync with one another. To change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart inside the back cover of this manual. Default = 1.

Number of Beeps – ErrorThe number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 - 9. For example, if you program this option to have five error beeps, there will be five error beeps and five LED flashes in response to an error. To change the number of error beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart inside the back cover of this manual. Default = 1.

Beeper Volume MaxScan the following bar code to set all error and good read beeps to the maximum volume. This feature also sets the Beeper Pitch – Good Read to the highest level.

Laser Aimer

Laser Aimer - Scanning PatternTo set the laser light pattern that appears when scanning a bar code, you must first enter an aimer delay (see Aimer Delay on page 3-7). Then scan one of the following bar codes to set a new scanning pattern.

Default = 10 Segment Line.

Number of Good Read Beeps/LED Flashes

Number of Error Beeps/LED Flashes

Beeper Volume Max

Laser Aimer - Scanning Pattern Off

Laser Aimer - Scanning Laser Dot

3 - 5

Page 32: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Laser Aimer - Scanning DurationUse the Laser Aimer - Scanning Duration bar code to specify how long you want the Laser Aimer - Scanning Pattern to remain on after the trigger is released. Scan the bar code below, then set the duration (from 0 - 65535 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 0 ms.

Laser Aimer - Good Read PatternOnce a bar code has been successfully read, you may want the laser light to remain on, but to display a different pattern than the scanning pattern. This gives the operator an additional visual indicator that the bar code was successfully read.

Scan one of the bar codes below to program your device for a Good Read Pattern. Default = 10 Segment Line.

Laser Aimer - Scanning Blinking Dot

Laser Aimer - Scanning 3 Segment Line

Laser Aimer - Scanning 5 Segment Line

* Laser Aimer - Scanning 10 Segment Line

Laser Aimer - Scanning Duration

Laser Aimer - Good Read Pattern Off

Laser Aimer - Good Read3 Segment Line

Laser Aimer - Good Read 5 Segment Line

3 - 6

Page 33: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Laser Aimer - Good Read DurationUse the Laser Aimer - Good Read Duration bar code to specify how long you want the Laser Aimer - Good Read Pattern to remain on after a bar code has been successfully read. Scan the bar code below, then set the duration (from 0 - 65535 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 0 ms.

Aimer DelayThe aimer delay allows a delay time for the operator to aim the scanner before the bar code is scanned. Use these codes to set the time between when the trigger is pulled and when the bar code is scanned. During the delay time, the aiming

light will appear, but scanning will not begin until the delay time is over. Default = Off.

User-Specified Aimer DelayIf you want to set your own length for the duration of the delay, scan the bar code below, then set the time-out by scan-ning digits (0 - 4,000 ms) from the Programming Chart inside the back cover of this manual, then scan Save.

* Laser Aimer - Good Read 10 Segment Line

Laser Aimer - Good Read Duration

200 milliseconds

400 milliseconds

* Off (no delay)

Delay Duration

3 - 7

Page 34: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

LED IndicatorsThe green and red LEDs can be programmed to be On or Off and at different brightness levels to indicate various scanner states. Use the following bar codes to program the LED indicators.

LED Settings

Default = Red LED On with Laser, Green LED On with Good Scan.

Red LED Off

Green LED Off

Red LED On with Good Scan

* Green LED On with Good Scan

* Red LED On with Laser

Green LED On with Laser

Red LED On when CodeGate Disabled

Green LED On when CodeGate Disabled

Red LED On with CTS

Green LED On with CTS

3 - 8

Page 35: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Good Read Delay

This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay).

User-Specified Good Read DelayIf you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0 - 30,000 mil-liseconds) by scanning digits from the inside back cover, then scanning Save.

Out-Of-Stand SettingsThe following settings program the scanner’s behavior when it is out of the stand, or hand-held.

Note: The Granit 1280i does not support In-Stand settings. It supports only the standard Honeywell Out-of-Stand settings.

Caution: When working with Out-of-Stand settings, enable the settings you want before disabling those you do not want to use. If you disable settings first, you may program the scanner so it is unable to read bar codes. if this happens, power cycle the scanner and scan the defaults bar code on page 1-2.

Out-of-Stand DefaultsIf you want the Out-of-Stand default settings restored to your scanner, scan the Out-of-Stand Defaults bar code below. This resets the scanner to the custom default settings (see Setting Custom Defaults on page 1-2). If there are no custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the cus-tom defaults will be defaulted to the factory default settings.

* No Delay

Short Delay (500 ms)

Medium Delay (1,000 ms)

Long Delay (1,500 ms)

User-Specified Good Read Delay

Out-of-Stand Defaults

3 - 9

Page 36: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Presentation ModeWhen the scanner is in Presentation Mode, it automatically detects bar codes, then scans and transmits the data. To set the time period before the scanner can read the same bar code a second time use Reread Delay (page 3-11). To return to trigger scanning, scan the Out-of-Stand Defaults bar code, above.

Manual Activation ModeIn Manual Activation Mode, you must press the trigger to scan a bar code. The scanner scans until a bar code is read, or until the trigger is released. Default = Manual Activation On Out-of-Stand.

End Manual Activation After Good ReadAfter a bar code is successfully read, the laser can be programmed either to remain on and scanning, or to turn off. When End Manual Activation After Good Read is enabled, the laser turns off and stops scanning after a good read. If you scan Do Not End Manual Activation After Good Read, the laser remains on after a good read, but the trigger must be pressed to scan the next bar code. Default = End Manual Activation After Good Read Out-of-Stand.

Presentation Mode Out-of-Stand

Manual Activation Mode OffOut-of-Stand

* Manual Activation Mode OnOut-of-Stand

Do Not End Manual Activation After Good Read Out-of-Stand

* End Manual Activation After Good Read Out-of-Stand

3 - 10

Page 37: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Manual Activation Laser Timeout - Trigger SettingsYou can set a timeout for the length of time the laser remains on and attempting to decode bar codes when the trigger is held down, and after it is released. Set the length (in milliseconds) for a timeout by scanning one of the following bar codes, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save.

Default = Trigger Hold Out-of-Stand 30,000 ms, Trigger Release Out-of-Stand 0.

Reread DelayThis sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads. Use shorter delays in applications where repetitive bar code scanning is required. Reread Delay only works when in a Presentation Mode (see page 3-9). Default = Medium.

User-Specified Reread DelayIf you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 millisec-onds) by scanning digits from the inside back cover, then scanning Save.

Laser Timeout - Trigger HoldOut-of-Stand

Laser Timeout - Trigger Release Out-of-Stand

Short (500 ms)

* Medium (750 ms)

Long (1000 ms)

Extra Long (2000 ms)

User-Specified Reread Delay

3 - 11

Page 38: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

CodeGate®

When CodeGate is On, the trigger is used to allow decoded data to be transmitted to the host system. The scanner remains on, scanning and decoding bar codes, but the bar code data is not transmitted until the trigger is pressed. When CodeGate is Off, bar code data is transmitted when it is decoded. Default = CodeGate On Out-of-Stand.

Character Activation ModeYou may use a character sent from the host to trigger the scanner to begin scanning. When the activation character is received, the scanner continues scanning until either the Character Activation Timeout (page 3-12), the deactivation character is received (see Deactivation Character on page 3-13), or a bar code is transmitted. Scan the following On bar code to use character acti-vation, then use Activation Character (following) to select the character you will send from the host to start scanning. Default = Off.

Activation CharacterThis sets the character used to trigger scanning when using Character Activation Mode. On the ASCII Conversion Chart (Code Page 1252), page A-2, find the hex value that represents the character you want to use to trigger scanning. Scan the following bar code, then use the Programming Chart to read the alphanumeric combination that represents that ASCII character. Scan Save to finish. Default = 18 [CAN].

CodeGate OffOut-of-Stand

* CodeGate OnOut-of-Stand

* Off

On

Activation Character

3 - 12

Page 39: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

End Character Activation After Good ReadAfter a bar code is successfully detected and read from the scanner, the illumination can be programmed either to remain on and scanning, or to turn off. When End Character Activation After Good Read is enabled, the illumination turns off and stops scanning after a good read. If you scan Do Not End Character Activation After Good Read, the illumination

remains on after a good read. Default = End Character Activation After Good Read.

Character Activation TimeoutYou can set a timeout for the length of time the illumination remains on and attempting to decode bar codes when using Character Activation Mode. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting the timeout (from 1-65,535 milliseconds) by scanning digits from the Programming Chart inside the back cover of this man-ual, then scanning Save. Default = 5000 ms.

Character Deactivation ModeIf you have sent a character from the host to trigger the scanner to begin scanning, you can also send a deactivation character to stop scanning. Scan the following On bar code to use character deactivation, then use Deactivation Character (following) to select the character you will send from the host to terminate scanning. Default = Off.

Do Not End Character Activation After Good Read

* End Character Activation After Good Read

Character Activation Timeout

* Off

On

3 - 13

Page 40: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Deactivation CharacterThis sets the character used to terminate scanning when using Character Deactivation Mode. On the ASCII Conversion Chart (Code Page 1252), page A-2, find the hex value that represents the character you want to use to terminate scanning. Scan the following bar code, then use the Programming Chart inside the back cover of this manual to read the alphanu-meric combination that represents that ASCII character. Scan Save to finish. Default = 68 [h].

CenteringUse Centering to narrow the scanner’s field of view to make sure that when the scanner is hand-held, it reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read. (Centering can be used in conjunction with Centering, page 3-13, for the most error-free operation in applications where multiple codes are spaced closely together. Using the Aimer Delay and Centering features, the scanner can emulate the operation of older systems, such as linear laser bar code scanners.)

If a bar code is not touched by a predefined window, it will not be decoded or output by the scanner. If centering is turned on by scanning Centering On, the scanner only reads codes that pass through the centering window you specify using the Left and Right of Centering Window bar codes.

In the example below, the white box is the centering window. The centering window has been set to 20% left and 30% right. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering win-dow, so it will not be read.

Note: A bar code needs only to be touched by the centering window in order to be read. It does not need to pass completely through the centering window.

Scan Centering On, then scan one of the following bar codes to change the left or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Cen-

tering = 40% Left, 60% Right.

Deactivation Character

0

Bar Code 1 Bar Code 2

10 20 30 40 50 60 70 80 90 100%

Centering On

* Centering Off

Left of Centering Window

3 - 14

Page 41: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Blinky ModeWhen either Blinky Mode On or Blinky Always On/Continuous is scanned, the scanner blinks on and off at 50% duty cycle

(250 milliseconds on, then 250 milliseconds off.) Default = Blinky Mode Off.

Laser Scan AngleThe laser scan angle can be set to several different widths in order to adjust to your particular scanning requirements.

Full Laser Beam Sweep: This is the default setting that produces a 13.5° laser beam.

Reduced Laser Beam Sweep: If you are aiming at a longer distance and the laser beam becomes too wide and touches adja-cent bar codes, you may need to adjust the width of the beam. In this case, scan the Reduced Laser Beam Sweep bar code below to narrow the laser beam.

Wide Laser Beam Sweep: If you have an exceptionally wide medium or high density bar code, you could use the wider sweep so the laser beam encompasses all of the code.

Note: When using Wide Laser Beam Sweep, the depth of field is reduced.

Right of Centering Window

* Blinky Mode Off

Blinky Mode On

Blinky Always On/Continuous

* Full Laser Beam Sweep

Reduced Laser Beam Sweep

Wide Laser Beam Sweep

3 - 15

Page 42: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Decode SecurityThis selection allows you to adjust the decode security needed while scanning. For good quality codes, choose Low to achieve fast scan speed. For codes prone to misreads, choose High. Default = Low.

Note: Increasing the security level may decrease the scan speed.

Continuous Scan ModeThis programs the engine to continuously scan and decode, with the laser and motor staying on.

Note: When operating in Continuous Scan Mode, the scanner’s upper operating temperature is 104°F (40°C).

Output Sequence Overview

Output Sequence EditorThis programming selection allows you to program the scanner to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the scanner to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol.

Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code length, and character match(es) your application requires. Use the Alphanumeric symbols (inside back cover) to read these options. You must hold the trigger while reading each bar code in the sequence.

To Add an Output Sequence1. Scan the Enter Sequence symbol (see Require Output Sequence, page 3-19).

2. Code I.D.On the Symbology Charts on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover).

3. LengthSpecify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number,

* Low

Low/Medium

Medium/High

High

Continuous Scan Mode

3 - 16

Page 43: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

indicating all lengths.) When calculating the length, you must count any programmed prefixes, suffixes, or formatted characters as part of the length (unless using 9999).

4. Character Match SequencesOn the ASCII Conversion Chart (Code Page 1252), page A-2, find the Hex value that represents the character(s) you want to match. Use the Programming Chart to read the alphanumeric combination that represents the ASCII characters. (99 is the Universal number, indicating all characters.)

5. End Output Sequence EditorScan F F to enter an Output Sequence for an additional symbology, or Save to save your entries.

Other Programming Selections• Discard

This exits without saving any Output Sequence changes.

Output Sequence ExampleIn this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.

Note: Code 93 must be enabled to use this example.

You would set up the sequence editor with the following command line:

SEQBLK62999941FF6A999942FF69999943FF

The breakdown of the command line is shown below:

SEQBLKsequence editor start command

62 code identifier for Code 39

9999 code length that must match for Code 39, 9999 = all lengths

41 start character match for Code 39, 41h = “A”

FF termination string for first code

6A code identifier for Code 128

9999 code length that must match for Code 128, 9999 = all lengths

42 start character match for Code 128, 42h = “B”

FF termination string for second code

69 code identifier for Code 93

9999 code length that must match for Code 93, 9999 = all lengths

43 start character match for Code 93, 43h = “C”

FF termination string for third code

To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or for-matted characters as part of the length. If you use the example on page 3-17, but assume a <CR> suffix and specific code lengths, you would use the following command line:

SEQBLK62001241FF6A001342FF69001243FF

A - Code 39

B - Code 128

C - Code 93

3 - 17

Page 44: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

The breakdown of the command line is shown below:

SEQBLKsequence editor start command

62 code identifier for Code 39

0012 A - Code 39 sample length (11) plus CR suffix (1) = 12

41 start character match for Code 39, 41h = “A”

FF termination string for first code

6A code identifier for Code 128

0013 B - Code 128 sample length (12) plus CR suffix (1) = 13

42 start character match for Code 128, 42h = “B”

FF termination string for second code

69 code identifier for Code 93

0012 C - Code 93 sample length (11) plus CR suffix (1) = 12

43 start character match for Code 93, 43h = “C”

FF termination string for third code

Output Sequence Editor

Sequence TimeoutYou may wish to set the maximum time between bar code scans in an output sequence. If that maximum time is not met, the output sequence operation is terminated. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 5000 msec.

Sequence Match BeeperBy default, the scanner beeps when a sequence match is found. If you want the scanner to remain silent, scan the follow-

ing Sequence Match Beeper Off bar code. Default = Sequence Match Beeper On.

Enter Sequence

Default Sequence

Sequence Timeout

Sequence Match Beeper Off

3 - 18

Page 45: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Partial SequenceIf an output sequence operation is terminated before all your output sequence criteria are met, the bar code data acquired to that point is a “partial sequence.”

Scan Discard Partial Sequence to discard partial sequences when the output sequence operation is terminated before completion. Scan Transmit Partial Sequence to transmit partial sequences. (Any fields in the sequence where no data match occurred will be skipped in the output.)

Require Output SequenceWhen an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is.

When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off.

Note: This selection is unavailable when the Multiple Symbols Selection is turned on.

* Sequence Match Beeper On

Transmit Partial Sequence

* Discard Partial Sequence

Required

On/Not Required

*Off

3 - 19

Page 46: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

No ReadWith No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data Window (see page 7-2), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off.

If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data Formatting beginning on page 5-1). The hex code for the No Read symbol is 9C.

On

* Off

3 - 20

Page 47: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

4

Data Editing

Prefix/Suffix OverviewWhen a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.

Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following illustration shows the breakdown of a message string:

Points to Keep In Mind• It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default

settings. Default prefix = None. Default suffix = None.• A prefix or suffix may be added or cleared from one symbology or all symbologies.• You can add any prefix or suffix from the ASCII Conversion Chart (Code Page 1252), beginning on page A-2, plus Code

I.D. and AIM I.D.• You can string together several entries for several symbologies at one time.• Enter prefixes and suffixes in the order in which you want them to appear on the output.• When setting up for specific symbologies (as opposed to all symbologies), the specific symbology ID value counts as an

added prefix or suffix character.• The maximum size of a prefix or suffix configuration is 200 characters, which includes header information.

To Add a Prefix or Suffix:

Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-2).

Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Charts, beginning on page A-1) for the symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”.

Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies.

Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252), beginning on page A-2, for the prefix or suffix you wish to enter.

Step 5. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual.

Step 6. Repeat Steps 4 and 5 for every prefix or suffix character.

Step 7. To add the Code I.D., scan 5, C, 8, 0. To add AIM I.D., scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C.

Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once to create the leading backslash and then to create the backslash itself.

Step 8. Scan Save to exit and save, or scan Discard to exit without saving.

Repeat Steps 1-6 to add a prefix or suffix for another symbology.

Prefix Scanned Data Suffix

1-11alpha numeric &control characters

variable length1-11alpha numeric &control characters

4 - 1

Page 48: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Example: Add a Tab Suffix to All Symbologies

Step 1. Scan Add Suffix.

Step 2. Scan 9, 9 from the Programming Chart inside the back cover of this manual to apply this suffix to all symbologies.

Step 3. Scan 0, 9 from the Programming Chart inside the back cover of this manual. This corresponds with the hex value for a horizontal tab, shown in the ASCII Conversion Chart (Code Page 1252), beginning on page A-2.

Step 4. Scan Save, or scan Discard to exit without saving.

To Clear One or All Prefixes or SuffixesYou can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. If you have been entering prefixes and suffixes for single symbologies, you can use Clear One Prefix (Suffix) to delete a specific character from a symbology. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted.

Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.

Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Charts, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix.

Step 3. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies.

Your change is automatically saved.

To Add a Carriage Return Suffix to All SymbologiesScan the following bar code if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies.

Prefix Selections

Suffix Selections

Add CR SuffixAll Symbologies

Add Prefix

Clear One Prefix

Clear All Prefixes

Add Suffix

4 - 2

Page 49: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Function Code TransmitWhen this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 7-2. When the

scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.

Communication Check CharacterTo enhance security, you can specify the transmission type of a check character; either LRC where the calculation starts on the first transmitted character, or LRC where the calculation starts on the second transmitted character.

Note: This option adds a check character to the bar code data for all symbologies. If you need to enable or disable check characters for individual symbologies, see Symbologies beginning on page 6-1.

Scan the following bar code to set the communication check character type. Default = None.

Intercharacter, Interfunction, and Intermessage DelaysSome terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity.

Clear One Suffix

Clear All Suffixes

* Enable

Disable

* None

LRC Starts on 1st Character

LRC Starts on 2nd Character

4 - 3

Page 50: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Intercharacter DelayAn intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.

To remove this delay, scan the Intercharacter Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.

User Specified Intercharacter DelayAn intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed after the transmission of a particular character of scanned data. Scan the Delay Length bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.

Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for the ASCII character that will trigger the delay ASCII Conversion Chart (Code Page 1252), beginning on page A-2.

To remove this delay, scan the Delay Length bar code, and set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.

Interfunction DelayAn interfunction delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each control character in the message string. Scan the Interfunction Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.

1 2 3 4 5

Intercharacter Delay

Prefix Scanned Data Suffix

Intercharacter Delay

Delay Length

Character to Trigger Delay

Interfunction Delays

Prefix Scanned Data Suffix

1 2 3 4 5STX HT CR LF

Interfunction Delay

4 - 4

Page 51: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

To remove this delay, scan the Interfunction Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.

Intermessage DelayAn intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission. Scan the Intermessage Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.

To remove this delay, scan the Intermessage Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.

2nd Scan Transmission1st Scan TransmissionIntermessage Delay

Intermessage Delay

4 - 5

Page 52: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

4 - 6

Page 53: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

5

Data Formatting

Data Format Editor IntroductionYou may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None.

Normally, when you scan a bar code, it is output automatically. However, when you create a format, you must use a “send” com-mand (see Send Commands on page 5-3) within the format program to output data.

Multiple formats may be programmed into the scanner. They are stacked in the order in which they are entered. However, the following list presents the order in which formats are applied:

1. Specific Terminal ID, Actual Code ID, Actual Length2. Specific Terminal ID, Actual Code ID, Universal Length3. Specific Terminal ID, Universal Code ID, Actual Length4. Specific Terminal ID, Universal Code ID, Universal Length5. Universal Terminal ID, Actual Code ID, Actual Length6. Universal Terminal ID, Actual Code ID, Universal Length7. Universal Terminal ID, Universal Code ID, Actual Length8. Universal Terminal ID, Universal Code ID, Universal Length

The maximum size of a data format configuration is 2000 bytes, which includes header information.

If a bar code is read that fails the first data format, the next data format, if there is one, will be used on the bar code data. If there is no other data format, the raw data is output.

If you have changed data format settings, and wish to clear all formats and return to the factory defaults, scan the Default Data Format code below.

Add a Data Format

Step 1. Scan the Enter Data Format symbol (page 5-2).

Step 2. Select Primary/Alternate FormatDetermine if this will be your primary data format, or one of 3 alternate formats. This allows you to save a total of 4 different data formats. To program your primary format, scan 0 using the Programming Chart inside the back cover of this manual. If you are programming an alternate format, scan 1, 2, or 3, depending on which alternate format you are programming. (See "Primary/Alternate Data Formats" on page 5-12 for further information.)

Step 3. Terminal TypeRefer to Terminal ID Table (page 5-3) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge.

Note: 099 indicates all terminal types.

Step 4. Code I.D.In the Symbology Charts, beginning on page A-1, find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual.

If you wish to create a data format for all symbologies, with the exception of some specific symbologies, refer to B8 (page 5-11).

Note: 99 indicates all symbologies.

* Default Data Format

5 - 1

Page 54: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Step 5. LengthSpecify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. For example, 50 characters is entered as 0050.

Note: 9999 indicates all lengths.

Step 6. Editor CommandsRefer to Data Format Editor Commands (page 5-3). Scan the symbols that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format.

Step 7. Scan Save to save your data format, or Discard to exit without saving your changes.

Other Programming SelectionsClear One Data Format

This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the format you are clearing. Scan the Terminal Type and Code I.D. (see Symbology Charts on page A-1), and the bar code data length for the specific data format that you want to delete. All other formats remain unaffected.

Clear all Data FormatsThis clears all data formats.

Save to exit and save your data format changes.

Discard to exit without saving any data format changes.

Enter Data Format

Save

Discard

Clear One Data Format

Clear All Data Formats

Save

Discard

5 - 2

Page 55: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Data Format Editor CommandsWhen working with the Data Format Editor, a virtual cursor is moved along your input data string. The following commands are used to both move this cursor to different positions, and to select, replace, and insert data into the final output.

Send CommandsSend all characters

F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character. Syntax = F1xx where xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

Send a number of charactersF2 Include in the output message a number of characters followed by an insert character. Start from the current cursor

position and continue for “nn” characters or through the last character in the input message, followed by character “xx.” Syntax = F2nnxx where nn stands for the numeric value (00-99) for the number of characters, and xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

F2 Example: Send a number of characters

Send the first 10 characters from the bar code above, followed by a carriage return. Command string: F2100D

F2 is the “Send a number of characters” command

10 is the number of characters to send

0D is the hex value for a CR

The data is output as: 1234567890

F2 and F1 Example: Split characters into 2 lines

Send the first 10 characters from the bar code above, followed by a carriage return, followed by the rest of the charac-ters.

Command string: F2100DF10D

F2 is the “Send a number of characters” command

10 is the number of characters to send for the first line

0D is the hex value for a CR

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 1234567890ABCDEFGHIJ<CR>

Terminal ID TableTerminal Model(s) Terminal IDSerial RS232 True 000

5 - 3

Page 56: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Send all characters up to a particular characterF3 Include in the output message all characters from the input message, starting with the character at the current cursor

position and continuing to, but not including, the search character “ss,” followed by an insert character. The cursor is moved forward to the “ss” character. Syntax = F3ssxx where ss stands for the search character’s hex value for its ASCII code, and xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

F3 Example: Send all characters up to a particular character

Using the bar code above, send all characters up to but not including “D,” followed by a carriage return.

Command string: F3440D

F3 is the “Send all characters up to a particular character” command

44 is the hex value for a 'D”

0D is the hex value for a CR

The data is output as: 1234567890ABC<CR>

Send all characters up to a stringB9 Include in the output message all characters from the input message, starting with the character at the current cursor

position and continuing to, but not including, the search string “s...s.” The cursor is moved forward to the beginning of the “s...s” string. Syntax = B9nnnns...s where nnnn stands for the length of the string, and s...s stands for the string to be matched. The string is made up of hex values for the characters in the string. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

B9 Example: Send all characters up to a defined string

Using the bar code above, send all characters up to but not including “AB.”

Command string: B900024142

B9 is the “Send all characters up to a string” command

0002 is the length of the string (2 characters)

41 is the hex value for A

42 is the hex value for B

The data is output as: 1234567890

Send all but the last charactersE9 Include in the output message all but the last “nn” characters, starting from the current cursor position. The cursor is

moved forward to one position past the last input message character included. Syntax = E9nn where nn stands for the numeric value (00-99) for the number of characters that will not be sent at the end of the message.

Insert a character multiple timesF4 Send “xx” character “nn” times in the output message, leaving the cursor in the current position. Syntax = F4xxnn where

xx stands for the insert character’s hex value for its ASCII code, and nn is the numeric value (00-99) for the number of times it should be sent. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

E9 and F4 Example: Send all but the last characters, followed by 2 tabs

Send all characters except for the last 8 from the bar code above, followed by 2 tabs.

5 - 4

Page 57: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Command string: E908F40902

E9 is the “Send all but the last characters” command

08 is the number of characters at the end to ignore

F4 is the “Insert a character multiple times” command

09 is the hex value for a horizontal tab

02 is the number of times the tab character is sent

The data is output as: 1234567890AB <tab><tab>

Insert a stringBA Send “ss” string of “nn” length in the output message, leaving the cursor in the current position. Syntax = BAnnnns...s

where nnnn stands for the length of the string, and s...s stands for the string. The string is made up of hex values for the characters in the string. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

B9 and BA Example: Look for the string “AB” and insert 2 asterisks (**)

Using the bar code above, send all characters up to but not including “AB.” Insert 2 asterisks at that point, and send the rest of the data with a carriage return after.

Command string: B900024142BA00022A2AF10D

B9 is the “Send all characters up to a string” command

0002 is the length of the string (2 characters)

41 is the hex value for A

42 is the hex value for B

BA is the “Insert a string” command

0002 is the length of the string to be added (2 characters)

2A is the hex value for an asterisk (*)

2A is the hex value for an asterisk (*)

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 1234567890**ABCDEFGHIJ<CR>

Insert symbology nameB3 Insert the name of the bar code’s symbology in the output message, without moving the cursor. Only symbologies with

a Honeywell ID are included (see Symbology Charts on page A-1). Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

Insert bar code lengthB4 Insert the bar code’s length in the output message, without moving the cursor. The length is expressed as a numeric

string and does not include leading zeroes.

B3 and B4 Example: Insert the symbology name and length

Send the symbology name and length before the bar code data from the bar code above. Break up these insertions with spaces. End with a carriage return.

Command string: B3F42001B4F42001F10D

5 - 5

Page 58: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

B3 is the “Insert symbology name” command

F4 is the “Insert a character multiple times” command

20 is the hex value for a space

01 is the number of times the space character is sent

B4 is the “Insert bar code length” command

F4 is the “Insert a character multiple times” command

20 is the hex value for a space

01 is the number of times the space character is sent

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: Code128 20 1234567890ABCDEFGHIJ<CR>

Insert key strokesB5 Insert a key stroke or combination of key strokes. Key strokes are dependent on your keyboard (see Unicode Key Maps

on page A-9). Any key can be inserted, including arrows and functions. Syntax = B5xxssnn where xx is the number of keys pressed (without key modifiers), ss is the key modifier from the table below, and nn is the key number from the Unicode Key Maps, page A-9.

For example, B501021F inserts an “A” on a 104 key, U.S. style keyboard. B5 = the command, 01 = number of keys pressed (without the key modifier), 02 is the key modifier for Shift Right, and 1F is the “a” key. If a lower case “a” were to be inserted, B501001F would be entered.

If there are three keystrokes, the syntax would change from B5xxssnn for one keystroke to B5xxssnnssnnssnn. An example that would insert "abc" is as follows: B503001F00320030F833.

Note: Key modifiers can be added together when needed. Example: Control Left+Shift Left = 11.

Move CommandsMove the cursor forward a number of characters

F5 Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn where nn is the numeric value (00-99) for the number of characters the cursor should be moved ahead.

F5 Example: Move the cursor forward and send the data

Move the cursor forward 3 characters, then send the rest of the bar code data from the bar code above. End with a carriage return.

Command string: F503F10D

F5 is the “Move the cursor forward a number of characters” command

03 is the number of characters to move the cursor

Key Modifiers

No Key Modifier 00

Shift Left 01Shift Right 02

Alt Left 04

Alt Right 08Control Left 10

Control Right 20

5 - 6

Page 59: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 4567890ABCDEFGHIJ<CR>

Move the cursor backward a number of charactersF6 Move the cursor back “nn” characters from current cursor position.

Syntax = F6nn where nn is the numeric value (00-99) for the number of characters the cursor should be moved back.

Move the cursor to the beginningF7 Move the cursor to the first character in the input message. Syntax = F7.

FE and F7 Example: Manipulate bar codes that begin with a 1

Search for bar codes that begin with a 1. If a bar code matches, move the cursor back to the beginning of the data and send 6 characters followed by a carriage return. Using the bar code above:

Command string: FE31F7F2060D

FE is the “Compare characters” command

31 is the hex value for 1

F7 is the “Move the cursor to the beginning” command

F2 is the “Send a number of characters” command

06 is the number of characters to send

0D is the hex value for a CR

The data is output as: 123456<CR>

Move the cursor to the endEA Move the cursor to the last character in the input message. Syntax = EA.

Search CommandsSearch forward for a character

F8 Search the input message forward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F8xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

F8 Example: Send bar code data that starts after a particular character

Search for the letter “D” in bar codes and send all the data that follows, including the “D.” Using the bar code above:

Command string: F844F10D

F8 is the “Search forward for a character” command

44 is the hex value for “D”

F1 is the “Send all characters” command

0D is the hex value for a CR

5 - 7

Page 60: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

The data is output as: DEFGHIJ<CR>

Search backward for a characterF9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to

the “xx” character. Syntax = F9xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

Search forward for a stringB0 Search forward for “s” string from the current cursor position, leaving cursor pointing to “s” string. Syntax = B0nnnnS

where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B0000454657374 will search forward for the first occurrence of the 4 character string “Test.”Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

B0 Example: Send bar code data that starts after a string of characters

Search for the letters “FGH” in bar codes and send all the data that follows, including “FGH.” Using the bar code above:

Command string: B00003464748F10D

B0 is the “Search forward for a string” command

0003 is the string length (3 characters)

46 is the hex value for “F”

47 is the hex value for “G”

48 is the hex value for “H”

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: FGHIJ<CR>

Search backward for a stringB1 Search backward for “s” string from the current cursor position, leaving cursor pointing to “s” string. Syntax = B1nnnnS

where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B1000454657374 will search backward for the first occurrence of the 4 character string “Test.”Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

Search forward for a non-matching characterE6 Search the input message forward for the first non-“xx” character from the current cursor position, leaving the cursor

pointing to the non-“xx” character. Syntax = E6xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

E6 Example: Remove zeroes at the beginning of bar code data

This example shows a bar code that has been zero filled. You may want to ignore the zeroes and send all the data that follows. E6 searches forward for the first character that is not zero, then sends all the data after, followed by a carriage return. Using the bar code above:

Command string: E630F10D

E6 is the “Search forward for a non-matching character” command

30 is the hex value for 0

5 - 8

Page 61: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 37692<CR>

Search backward for a non-matching characterE7 Search the input message backward for the first non-“xx” character from the current cursor position, leaving the cursor

pointing to the non-“xx” character. Syntax = E7xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

Miscellaneous CommandsSuppress characters

FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number of suppressed characters in the list, and xxyy .. zz is the list of characters to be suppressed.

FB Example: Remove spaces in bar code data

This example shows a bar code that has spaces in the data. You may want to remove the spaces before sending the data. Using the bar code above:

Command string: FB0120F10D

FB is the “Suppress characters” command

01 is the number of character types to be suppressed

20 is the hex value for a space

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 34567890<CR>

Stop suppressing charactersFC Disables suppress filter and clear all suppressed characters. Syntax = FC.

Replace charactersE4 Replaces up to 15 characters in the output message, without moving the cursor. Replacement continues until the E5

command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of the number of characters in the list (characters to be replaced plus replacement characters); xx1 defines characters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2.

E4 Example: Replace zeroes with CRs in bar code data

If the bar code has characters that the host application does not want included, you can use the E4 command to replace those characters with something else. In this example, you will replace the zeroes in the bar code above with carriage returns.

Command string: E402300DF10D

E4 is the “Replace characters” command

5 - 9

Page 62: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

02 is the total count of characters to be replaced, plus the replacement characters (0 is replaced by CR, so total char-acters = 2)

30 is the hex value for 0

0D is the hex value for a CR (the character that will replace the 0)

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 12345678ABC<CR>

Stop replacing charactersE5 Terminates character replacement. Syntax = E5.

Compare charactersFE Compare the character in the current cursor position to the character “xx.” If characters are equal, move the cursor

forward one position. Syntax = FExx where xx stands for the comparison character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

Compare stringB2 Compare the string in the input message to the string “s.” If the strings are equal, move the cursor forward past the end

of the string. Syntax = B2nnnnS where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B2000454657374 will compare the string at the current cursor position with the 4 character string “Test.” Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-2 for decimal, hex and character codes.

Check for a numberEC Check to make sure there is an ASCII number at the current cursor position. The format is aborted if the character is

not numeric.

EC Example: Only output the data if the bar code begins with a number

If you want only data from bar codes that begin with a number, you can use EC to check for the number.

Command string: ECF10D

EC is the “Check for a number” command

F1 is the “Send all characters” command

0D is the hex value for a CR

If this bar code is read, the next data format, if there is one, will be used on the data. If there

is no other format, the format fails and the raw data is output as AB1234.

If this bar code is read: the data is output as:

1234AB<CR>

Check for non-numeric characterED Check to make sure there is a non-numeric ASCII character at the current cursor position. The format is aborted if the

character is numeric.

ED Example: Only output the data if the bar code begins with a letter

If you want only data from bar codes that begin with a letter, you can use ED to check for the letter.

Command string: EDF10D

5 - 10

Page 63: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ED is the “Check for a non-numeric character” command

F1 is the “Send all characters” command

0D is the hex value for a CR

If this bar code is read, the next data format, if there is one, will be used on this data. If there

is no other format, the format fails and the raw data is output as 1234AB.

If this bar code is read: the data is output as:

AB1234<CR>

Insert a delayEF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position. Syntax = EFnnnn

where nnnn stands for the delay in 5ms increments, up to 9999. This command can only be used with keyboard emulation.a

Discard DataB8 Discards types of data. For example, you may want to discard Code 128 bar codes that begin with the letter A. In step

4 (page 5-1), select 6A (for Code 128), and in step 5, select 9999 (for all lengths). Enter FE41B8 to compare and discard Code 128 bar codes that begin with the letter A. Syntax = B8.

Note: The B8 command must be entered after all other commands. The Data Format must be Required (see page 5-11) in order for the B8 command to work. If Data Format is On, but Not Required (page 5-12), bar code data that meets the B8 format is scanned and output as usual. Because the data format needs to be On and Required (page 5-12) for the B8 command, you must input data formats for all bar codes you wish to discard as well as all bar codes you wish to output.Other data format settings impact the B8 command. If Data Format Non-Match Error Tone is On (page 5-12), the scanner emits an error tone. If Data format Non-Match Error Tone is Off, the code is disabled for reading and no tone is sounded.

Data FormatterWhen Data Formatter is turned Off, the bar code data is output to the host as read, including prefixes and suffixes.

You may wish to require the data to conform to a data format you have created and saved. The following settings can be applied to your data format:

Data Formatter On, Not Required, Keep Prefix/SuffixScanned data is modified according to your data format, and prefixes and suffixes are transmitted.

Data Formatter On, Not Required, Drop Prefix/SuffixScanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and suffixes are not transmitted. If a data format is not found for that symbol, the prefixes and suffixes are transmitted.

Data Format Required, Keep Prefix/SuffixScanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted. If you wish to process this type of bar code without generating an error tone, see Data Format Non-Match Error Tone.

Data Format Required, Drop Prefix/SuffixScanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and suffixes are not transmitted. Any data that does not match your data format requirements generates an error tone. If you wish to process this type of bar code without generating an error tone, see Data Format Non-Match Error Tone.

Data Formatter Off

5 - 11

Page 64: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Choose one of the following options. Default = Data Formatter On, Not Required, Keep Prefix/Suffix.

Data Format Non-Match Error ToneWhen a bar code is encountered that doesn’t match your required data format, the scanner normally generates an error tone. However, you may want to continue scanning bar codes without hearing the error tone. If you scan the Data Format Non-Match Error Tone Off bar code, data that doesn’t conform to your data format is not transmitted, and no error tone will sound. If you wish to hear the error tone when a non-matching bar code is found, scan the Data Format Non-Match Error Tone On bar code. Default = Data Format Non-Match Error Tone On.

Primary/Alternate Data FormatsYou can save up to four data formats, and switch between these formats. Your primary data format is saved under 0. Your other

three formats are saved under 1, 2, and 3. To set your device to use one of these formats, scan one of the bar codes below.

* Data Formatter On,Not Required,

Keep Prefix/Suffix

Data Formatter On,Not Required,

Drop Prefix/Suffix

Data Format Required,Keep Prefix/Suffix

Data Format Required,Drop Prefix/Suffix

* Data Format Non-Match Error Tone On

Data Format Non-Match Error Tone Off

Primary Data Format

5 - 12

Page 65: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Single Scan Data Format ChangeYou can also switch between data formats for a single scan. The next bar code is scanned using an alternate data format, then reverts to the format you have selected above (either Primary, 1, 2, or 3).

For example, you may have set your device to the data format you saved as Data Format 3. You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan-Data Format 1 bar code below. The next bar code that is scanned

uses Data Format 1, then reverts back to Data Format 3.

Data Format 1

Data Format 2

Data Format 3

Single Scan-Primary Data Format

Single Scan-Data Format 1

Single Scan-Data Format 2

Single Scan-Data Format 3

5 - 13

Page 66: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

5 - 14

Page 67: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

6

Symbologies

This programming section contains the following menu selections. Refer to Chapter 8 for settings and defaults.

All SymbologiesIf you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular sym-

bology.

Message Length DescriptionYou are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error tone. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread.

EXAMPLE: Decode only those bar codes with a count of 9-20 characters.Min. length = 09Max. length = 20

EXAMPLE: Decode only those bar codes with a count of 15 characters.Min. length = 15Max. length = 15

For a value other than the minimum and maximum message length defaults, scan the bar codes included in the explanation of the symbology, then scan the digit value of the message length and Save bar codes on the Programming Chart inside the back cover of this manual. The minimum and maximum lengths and the defaults are included with the respective symbologies.

• All Symbologies • GS1 Emulation

• China Post (Hong Kong 2 of 5) • GS1-128

• Codabar • Interleaved 2 of 5

• Code 11 • Matrix 2 of 5

• Code 128 • MSI

• Code 32 Pharmaceutical (PARAF) • NEC 2 of 5

• Code 39 • Plessey Code

• Code 93 • Straight 2 of 5 IATA (two-bar start/stop)

• EAN/JAN-13 • Straight 2 of 5 Industrial (three-bar start/stop)

• EAN/JAN-8 • Telepen

• GS1 DataBar Expanded • Trioptic Code

• GS1 DataBar Limited • UPC-A

• GS1 DataBar Omnidirectional • UPC-A/EAN-13 with Extended Coupon Code

• UPC-E0

All Symbologies On

All Symbologies Off

6 - 1

Page 68: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Codabar<Default All Codabar Settings>

Codabar On/Off

Codabar Start/Stop CharactersStart/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.

Codabar Check CharacterCodabar check characters are created using different “modulos.” You can program the scanner to read only Codabar bar codes with Modulo 16 check characters. Default = No Check Character.

No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.

When Check Character is set to Validate and Transmit, the scanner will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data.

When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a

check character, but will not transmit the check character with the scanned data.

* On

Off

Transmit

* Don’t Transmit

* No Check Character

Validate Modulo 16, butDon’t Transmit

6 - 2

Page 69: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Codabar ConcatenationCodabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted.

Select Require to prevent the scanner from decoding a single “D” Codabar symbol without its companion. This selection

has no effect on Codabar symbols without Stop/Start D characters.

Validate Modulo 16 and Transmit

Validate Modulo 7 CD, but Don’t Transmit

Validate Modulo 7 CD and Transmit

Validate CLSI, but Don’t Transmit

Validate CLSI and Transmit

A 1 2 3 4 D D 5 6 7 8 A

On

* Off

Require

6 - 3

Page 70: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Concatenation TimeoutWhen searching for bar codes during concatenation, you may wish to set a delay used to find the next bar code. Set the length (in milliseconds) for this delay by scanning the following bar code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 750.

Codabar RedundancyIf you are encountering errors when reading Codabar bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the following Codabar Redundancy bar code, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Codabar Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

Concatenation Timeout

Codabar Redundancy

Minimum Message Length

Maximum Message Length

6 - 4

Page 71: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 39< Default All Code 39 Settings >

Code 39 On/Off

Code 39 Start/Stop CharactersStart/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/

Stop characters. Default = Don’t Transmit.

Code 39 Check CharacterNo Check Character indicates that the scanner reads and transmits bar code data with or without a check character.

When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data.

When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character.

* On

Off

Transmit

* Don’t Transmit

* No Check Character

Validate, but Don’t Transmit

Validate and Transmit

6 - 5

Page 72: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 39 RedundancyIf you are encountering errors when reading Code 39 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Code 39 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Code 39 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

Code 39 AppendThis function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 39 bar code with the append trigger character(s), it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger. The data is then transmitted in the

order in which the bar codes were read (FIFO). Default = Off.

Code 32 Pharmaceutical (PARAF)Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF.

Note: Trioptic Code (page 6-50) must be turned off while scanning Code 32 Pharmaceutical codes.

Code 39 Redundancy

Minimum Message Length

Maximum Message Length

On

* Off

On

6 - 6

Page 73: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Full ASCIIIf Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.

Character pairs /M and /N decode as a minus sign and period respectively.

Character pairs /P through /Y decode as 0 through 9.

Code 39 Code PageCode pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.

NUL %U DLE $P SP SPACE 0 0 @ %V P P ‘ %W p +P

SOH $A DC1 $Q ! /A 1 1 A A Q Q a +A q +Q

STX $B DC2 $R “ /B 2 2 B B R R b +B r +R

ETX $C DC3 $S # /C 3 3 C C S S c +C s +S

EOT $D DC4 $T $ /D 4 4 D D T T d +D t +T

ENQ $E NAK $U % /E 5 5 E E U U e +E u +U

ACK $F SYN $V & /F 6 6 F F V V f +F v +V

BEL $G ETB $W ‘ /G 7 7 G G W W g +G w +W

BS $H CAN $X ( /H 8 8 H H X X h +H x +X

HT $I EM $Y ) /I 9 9 I I Y Y i +I y +Y

LF $J SUB $Z * /J : /Z J J Z Z j +J z +Z

VT $K ESC %A + /K ; %F K K [ %K k +K %P

FF $L FS %B , /L < %G L L \ %L l +L | %Q

CR $M GS %C - - = %H M M ] %M m +M %R

SO $N RS %D . . > %I N N ^ %N n +N ~ %S

SI $O US %E / /O ? %J O O _ %O o +O DEL %T

* Off

Full ASCII On

* Full ASCII Off

Code 39 Code Page

6 - 7

Page 74: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Interleaved 2 of 5< Default All Interleaved 2 of 5 Settings >

Interleaved 2 of 5 On/Off

NULL CharactersInterleaved 2 of 5 requires an even number of characters. When an odd number of characters is present, it is due to NULL characters embedded in the bar code. Scan the On bar code below to decode this type of Interleaved 2 of 5 bar code. Default = Off.

Check DigitNo Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit.

When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.

When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a

check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit.

* On

Off

* Off

On

* No Check Digit

Validate, but Don’t Transmit

6 - 8

Page 75: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Interleaved 2 of 5 RedundancyIf you are encountering errors when reading Interleaved 2 of 5 bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Interleaved 2 of 5 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Interleaved 2 of 5 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.

Matrix 2 of 5<Default All Matrix 2 of 5 Settings>

Matrix 2 of 5 On/Off

Matrix 2 of 5 Check CharacterNo Check Character indicates that the scanner reads and transmits bar code data with or without a check character.

Validate and Transmit

Interleaved 2 of 5 Redundancy

Minimum Message Length

Maximum Message Length

On

* Off

6 - 9

Page 76: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

When Check Character is set to Validate, but Don’t Transmit, the unit only reads Matrix 2 of 5 bar codes printed with a check character, but will not transmit the check character with the scanned data.

When Check Character is set to Validate and Transmit, the scanner only reads Matrix 2 of 5 bar codes printed with a

check character, and will transmit this character at the end of the scanned data. Default = No Check Character.

Matrix 2 of 5 RedundancyIf you are encountering errors when reading Matrix 2 of 5 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Matrix 2 of 5 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Matrix 2 of 5 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

* No Check Character

Validate, but Don’t Transmit

Validate and Transmit

Matrix 2 of 5 Redundancy

Minimum Message Length

Maximum Message Length

6 - 10

Page 77: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

NEC 2 of 5< Default All NEC 2 of 5 Settings >

NEC 2 of 5 On/Off

Check DigitNo Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit.

When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.

When Check Digit is set to Validate and Transmit, the scanner only reads NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit.

NEC 2 of 5 RedundancyIf you are encountering errors when reading NEC 2 of 5 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the NEC 2 of 5 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

On

* Off

* No Check Digit

Validate, but Don’t Transmit

Validate and Transmit

NEC 2 of 5 Redundancy

6 - 11

Page 78: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

NEC 2 of 5 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

Code 93< Default All Code 93 Settings >

Code 93 On/Off

Code 93 RedundancyIf you are encountering errors when reading Code 93 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Code 93 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Minimum Message Length

Maximum Message Length

* On

Off

Code 93 Redundancy

6 - 12

Page 79: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 93 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

Code 93 AppendThis function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 93 bar codes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data. The scanner stores the data in the order in which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when

it reads a Code 93 bar code that starts with a character other than a space. Default = Off.

Code 93 Code PageCode pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.

Minimum Message Length

Maximum Message Length

On

* Off

Code 93 Code Page

6 - 13

Page 80: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Straight 2 of 5 Industrial (three-bar start/stop)<Default All Straight 2 of 5 Industrial Settings>

Straight 2 of 5 Industrial On/Off

Straight 2 of 5 Industrial RedundancyIf you are encountering errors when reading Straight 2 of 5 Industrial bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redun-dancy, scan the Straight 2 of 5 Industrial Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Straight 2 of 5 Industrial Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

On

* Off

Straight 2 of 5 Industrial Redundancy

Minimum Message Length

Maximum Message Length

6 - 14

Page 81: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Straight 2 of 5 IATA (two-bar start/stop)<Default All Straight 2 of 5 IATA Settings>

Straight 2 of 5 IATA On/Off

Straight 2 of 5 IATA RedundancyIf you are encountering errors when reading Straight 2 of 5 IATA bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Straight 2 of 5 IATA Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Straight 2 of 5 IATA Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 13, Maximum Default = 15.

On

* Off

Straight 2 of 5 IATA Redundancy

Minimum Message Length

Maximum Message Length

6 - 15

Page 82: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 11<Default All Code 11 Settings>

Code 11 On/Off

Check Digits Required

This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits.

Code 11 RedundancyIf you are encountering errors when reading Code 11 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Code 11 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Code 11 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

On

* Off

One Check Digit

* Two Check Digits

Code 11 Redundancy

Minimum Message Length

6 - 16

Page 83: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 128<Default All Code 128 Settings>

Code 128 On/Off

128 Group Separator OutputIf you wish to transmit embedded FNC1 characters as group separators (1B hex) with your Code 128 bar code output, scan the On bar code. When Off is scanned, nothing is transmitted for FNC1 characters. Default =Off.

Code 128 RedundancyIf you are encountering errors when reading Code 128 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Code 128 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Maximum Message Length

* On

Off

On

* Off

Code 128 Redundancy

6 - 17

Page 84: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 128 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 0-80. Minimum Default = 3, Maximum Default = 80.

Code 128 AppendThis function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 128 bar code with the append trigger character(s), it buffers Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigger. The data is then transmitted

in the order in which the bar codes were read (FIFO). Default = On.

ISBT 128 ConcatenationIn 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood informa-tion in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation of neigh-boring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concat-enation on or off. Default =Off.

Minimum Message Length

Maximum Message Length

* On

Off

On

* Off

6 - 18

Page 85: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Concatenation TimeoutWhen searching for bar codes during concatenation, you may wish to set a delay used to find the next bar code. Set the length (in milliseconds) for this delay by scanning the following bar code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 750.

ISBT 128 Predefined Concatenation SequencesNote: You must enable Code 128 and ISBT 128 to use this feature.

The following bar codes are used to select the pre-defined ISBT 128 Concatenation Sequence you wish to use. Once you have selected the concatenation sequence, use ISBT 128 Predefined Concatenation Sequences On/Off to enable this fea-ture. Default = Donation ID Number (001)

and ABO/RhD Blood Groups (002).

Concatenation Timeout

* Donation ID Number (001)and ABO/RhD Blood Groups (002)

Donation ID Number (001) andDonor ID Number (019)

Donation ID Number (001) and Confidential Unit Exclusion

Status

Product Code (003) and Expiration Date (Form 1)

Product Code (003) and Expiration Date (Form 2)

Product Code (003) and Expiration Date (Form 3)

Product Code (003) and Expiration Date (Form 4)

6 - 19

Page 86: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ISBT 128 Predefined Concatenation Sequences On/OffThe following selections allow you to enable or require the Predefined ISBT 128 Concatenation Sequences.

If you scan Off, the predefined concatenation sequences are disabled.

If you scan the Allow Predefined Sequence code, then the scanner will output only the data combination specified in the predefined concatenation sequence you selected.

If you scan the Require Predefined Sequence code, the data combination specified in the predefined concatenation sequence you selected is required to transmit the data. No data is output unless the sequence is read.

Default = Off.

ISBT 128 User-Defined Concatenation SequencesNote: You must enable Code 128 and ISBT 128 to use this feature.

The following bar codes are used to create a custom ISBT 128 Concatenation Sequence. Select the identifiers you want to transmit in the 1st and 2nd positions, both left and right. Refer to the ISBT 128 Standard Technical Specification for the list of data identifiers.

Use the ASCII Conversion Chart (Code Page 1252), page A-2, to find the characters needed for the identifier. Locate the hex value for each character and scan that 2 digit/character value from the Programming Chart inside the back cover of this manual.

Example: You want to create a concatenation sequence that has the Donation Identification Number (001) as the left iden-tifier, and Product Code (003) as the right identifier.

The ISBT Index of Data Structures shows that for the Donation Identification Number, the first character is “=” and the sec-ond character can be from A-N; P-Z; 1-9. For this example, use “G.” The Product Code first character is “=” and the second character is “<.”

* Off

Allow Predefined Sequence

Require Predefined Sequence

6 - 20

Page 87: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Step 1. Scan the 1st Left Identifier bar code, below.

Step 2. Use the Programming Chart to scan 3, D (hex for “=”).

Step 3. Scan Save.

Step 4. Scan the 2nd Left Identifier bar code, below.

Step 5. Use the Programming Chart to scan 4, 7 (hex for “G”).

Step 6. Scan Save.

Step 7. Scan the 1st Right Identifier bar code, below.

Step 8. Use the Programming Chart to scan 3, D (hex for “=”).

Step 9. Scan Save.

Step 10. Scan the 2nd Right Identifier bar code, below.

Step 11. Use the Programming Chart to scan 3, C (hex for “<”).

Step 12. Scan Save.

Once you have programmed the concatenation sequence, use ISBT 128 User-Defined Concatenation Sequences to

enable this feature. Default = 0.

ISBT 128 User-Defined Concatenation Sequences On/OffThe following selections allow you to enable or require the User-Defined ISBT 128 Concatenation Sequences.

If you scan Off, the User-Defined concatenation sequences are disabled.

If you scan the Allow User-Defined Sequence code, then the scanner will output only the data combination specified in the User-Defined concatenation sequence you created.

If you scan the Require User-Defined Sequence code, the data combination specified in the User-Defined concatenation sequence is required to transmit the data. No data is output unless the sequence is read.

Default = Off.

1st Left Identifier

2nd Left Identifier

1st Right Identifier

2nd Right Identifier

* Off

6 - 21

Page 88: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Content VerificationWhen the On bar code is scanned, the check character values are output along with the bar code data, thus allowing you to

verify that the check character is in agreement with that calculated for the data stream. Default = Off.

Transmit IdentifiersYou may disable the transmission of the ISBT Code 128 data identifiers by scanning Off. When this selection is Off, the first 2 data (ID) characters are removed from the data stream unless the ISBT code contains the Donation Identification Number identifiers. If the code contains the Donation Identification Number identifiers, only the first ID character is

removed from the Donation Identification Number. The second character is transmitted as normal data. Default = On.

Flag Digit ConversionType 3 flag digits are a part of the Donation Identification Number in an ISBT 128 bar code. If you select On, the flag data is converted into a single MOD (37, 2) character and transmitted with the bar code data. Scan Off if you do not want the

flag digits transmitted. Default = Off.

Allow User-Defined Sequence

Require User-Defined Sequence

On

* Off

* On

Off

On

* Off

6 - 22

Page 89: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

GS1-128<Default All GS1-128 Settings>

GS1-128 On/Off

GS1-128 Application Identifier ParsingThis allows a single GS1-128 bar code to be broken into multiple transmissions based on the presence of application iden-tifiers (AI) embedded in the bar code. To use this feature, first enable 128 Group Separator Output (page 6-17). Next, scan Transmit Without Identifiers if you want the bar code broken into packets and stripped of the AI. If you want the AI

included, scan Transmit With Identifiers. Default = Off.

GS1-128 RedundancyIf you are encountering errors when reading GS1-128 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the GS1-128 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

* On

Off

* Off

Transmit Without Identifiers

Transmit With Identifiers

GS1-128 Redundancy

6 - 23

Page 90: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

GS1-128 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

Telepen<Default All Telepen Settings>

Telepen On/Off

Telepen OutputUsing AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and

decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.

Minimum Message Length

Maximum Message Length

On

* Off

* AIM Telepen Output

Original Telepen Output

6 - 24

Page 91: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Telepen RedundancyIf you are encountering errors when reading Telepen bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Telepen Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Telepen Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

UPC-A<Default All UPC-A Settings>

UPC-A On/Off

Note: To convert UPC-A bar codes to EAN-13, see Convert UPC-A to EAN-13 on page 6-34.

Telepen Redundancy

Minimum Message Length

Maximum Message Length

* On

Off

6 - 25

Page 92: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

UPC-A Check DigitThis selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.

Default = On.

UPC-A Number SystemThe numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can

be programmed so it will not transmit it. Default = On.

UPC-A AddendaThis selection adds 2 or 5 digits to the end of all scanned UPC-A data.Default = Off for both 2 Digit and 5 Digit Addenda.

* On

Off

* On

Off

2 Digit Addenda On

* 2 Digit Addenda Off

5 Digit Addenda On

* 5 Digit Addenda Off

6 - 26

Page 93: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

UPC-A Addenda RequiredWhen Required is scanned, the scanner will only read UPC-A bar codes that have addenda. You must then turn on a 2 or

5 digit addenda listed on page 6-26. Default = Not Required.

UPC-A Addenda SeparatorWhen this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On.

Addenda TimeoutYou can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A/EAN-13 with Extended Coupon Code or UPC-A Number System 4 Addenda Required. Set the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100.

Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.

UPC-A RedundancyIf you are encountering errors when reading UPC-A bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the UPC-A Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Required

* Not Required

* On

Off

Addenda Timeout

UPC-A Redundancy

6 - 27

Page 94: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

UPC-A/EAN-13 with Extended Coupon CodeUse the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. When left on the default setting (Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes.

If you scan the Allow Concatenation code, when the scanner sees the coupon code and the extended coupon code in a single scan, it transmits both as separate symbologies. Otherwise, it transmits the first coupon code it reads.

If you scan the Require Concatenation code, the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data. No data is output unless both codes are read. Default = Off.

UPC-A/Code 128 Coupon Code OutputThese settings are used when a coupon code and a Code 128 bar code are detected in the same scan. Scan Multiple Code Output to transmit both codes as separate bar codes with separate terminators. Scan Single Code Output to trans-

mit the data as one extended bar code. Default = Multiple Code Output.

UPC-A Number System 4 Addenda Required This setting programs the scanner to require a coupon code only on UPC-A bar codes that begin with a “4.” The following settings can be programmed:

Require Coupon Code: All UPC-A bar codes that begin with a “4” must have a coupon code. The UPC-A bar code with the coupon code is then transmitted as a single, concatenated bar code. If a coupon code is not found within the Addenda Timeout period, the UPC-A bar code is discarded.

Don’t Require Coupon Code: If you have selected Require Coupon Code, and you want to disable this feature, scan Don’t Require Coupon Code. UPC-A bar codes are transmitted, depending on the setting you are using for UPC-A/EAN-13 with Extended Coupon Code.

* Off

Allow Concatenation

Require Concatenation

* Multiple Code Output

Single Code Output

6 - 28

Page 95: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Default = Don’t Require Coupon Code.

UPC-A Number System 5 Addenda Required This setting programs the scanner to require any combination of a coupon code, a 2 digit addenda, or a 5 digit addenda on UPC-A bar codes that begin with a “5.” The following settings can be programmed:

Require Coupon Code/Addenda: All UPC-A bar codes that begin with a “5” must have a coupon code, a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The UPC-A bar code with the coupon code and/or addenda is then transmitted as a single, concatenated bar code. If a coupon code and/or required addenda is not found within the Addenda Timeout period, the UPC-A bar code is discarded.

Don’t Require Coupon Code/Addenda: If you have selected Require Coupon Code/Addenda, and you want to disable this feature, scan Don’t Require Coupon Code/Addenda. UPC-A bar codes are transmitted, depending on the setting you are using for UPC-A/EAN-13 with Extended Coupon Code.

Default = Don’t Require Coupon Code/Addenda.

* Don’t Require Coupon Code

Require Coupon Code

* Don’t Require Coupon Code/Addenda

Require 2 Digit Addenda

Require 5 Digit Addenda

Require 2 or 5 Digit Addenda

Require Coupon Code

Require Coupon Code or 2 Digit Addenda

6 - 29

Page 96: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Addenda TimeoutYou can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A/EAN-13 with Extended Coupon Code or UPC-A Number System 4 Addenda Required. Set the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100.

Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.

Coupon GS1 DataBar OutputIf you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data. Default = GS1 Output Off.

Addenda TimeoutYou can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A/EAN-13 with Extended Coupon Code or UPC-A Number System 4 Addenda Required. Set the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100.

Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.

Require Coupon Code or 5 Digit Addenda

Require Coupon Code, 2 Digit Addenda, or 5 Digit Addenda

Addenda Timeout

* GS1 Output Off

GS1 Output On

Addenda Timeout

6 - 30

Page 97: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

UPC-E0<Default All UPC-E Settings>

UPC-E0 On/Off

Most U.P.C. bar codes lead with the 0 number system. To read these codes, use the UPC-E0 On selection. Default = On.

UPC-E0 Expand

UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off.

UPC-E0 Number SystemThe numeric system digit of a UPC-A symbol is normally transmitted at the beginning of scanned data. When using UPC-

E Expand, the unit can be programmed so it will not transmit it. Default = On.

* UPC-E0 On

UPC-E0 Off

On

* Off

* On

Off

6 - 31

Page 98: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

UPC-E0 Number System and Check Digit

UPC-E0 Addenda Required

When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required.

UPC-E0 Addenda SeparatorWhen this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned

Off, there is no space. Default = Off.

UPC-E0 Check Digit

Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = Off.

Check Digit

Number

UPC-E0 sample showing the number system and check digit:

Required

* Not Required

On

* Off

On

* Off

6 - 32

Page 99: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

UPC-E0 Leading ZeroThis feature allows the transmission of a leading zero (0) at the beginning of scanned data. To prevent transmission, scan

Off. Default = Off.

UPC-E0 Addenda

This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda.

UPC-E0 RedundancyIf you are encountering errors when reading UPC-E0 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the UPC-E0 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 1.

On

* Off

2 Digit Addenda On

* 2 Digit Addenda Off

5 Digit Addenda On

* 5 Digit Addenda Off

UPC-E0 Redundancy

6 - 33

Page 100: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EAN/JAN-13<Default All EAN/JAN Settings>

EAN/JAN-13 On/Off

Convert UPC-A to EAN-13When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A. Default = Do not Convert

UPC-A.

EAN/JAN-13 Check DigitThis selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.

Default = On.

* On

Off

UPC-A Converted to EAN-13

* Do not Convert UPC-A

* On

Off

6 - 34

Page 101: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EAN/JAN-13 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit

Addenda.

EAN/JAN-13 Addenda Required

When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda. Default = Not Required.

EAN-13 Beginning with 2 Addenda RequiredThis setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with a “2.” The follow-ing settings can be programmed:

Require 2 Digit Addenda: All EAN-13 bar codes that begin with a “2” must have a 2 digit addendum. The EAN-13 bar code with the 2 digit addendum is then transmitted as a single, concatenated bar code. If a 2 digit addendum is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

Note: if you are using EAN-13 Beginning with 290 Addenda Required (page 6-36), that setting will take precedence over this one.

Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit Addenda, and you want to disable this feature, scan Don’t Require 2 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

2 Digit Addenda On

* 2 Digit Addenda Off

5 Digit Addenda On

* 5 Digit Addenda Off

Required

* Not Required

6 - 35

Page 102: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Default = Don’t Require 2 Digit Addenda.

EAN-13 Beginning with 290 Addenda RequiredThis setting programs the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “290.” The follow-ing settings can be programmed:

Require 5 Digit Addenda: All EAN-13 bar codes that begin with “290” must have a 5 digit addendum. The EAN-13 bar code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

Note: if you are using EAN-13 Beginning with 2 Addenda Required (page 6-35), this setting will take precedence.

Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature, scan Don’t Require 5 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

Default = Don’t Require 5 Digit Addenda.

EAN-13 Beginning with 378/379 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “378” or “379.” The following settings can be programmed:

Require Addenda: All EAN-13 bar codes that begin with a “378” or “379” must have a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The EAN-13 bar code with the addenda is then transmitted as a single, concatenated bar code. If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

Don’t Require Addenda: If you have selected Require Addenda, and you want to disable this feature, scan Don’t Require Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

Default = Don’t Require Addenda.

* Don’t Require 2 Digit Addenda

Require 2 Digit Addenda

* Don’t Require 5 Digit Addenda

Require 5 Digit Addenda

* Don’t Require Addenda

6 - 36

Page 103: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EAN-13 Beginning with 414/419 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “414” or “419.” The following settings can be programmed:

Require Addenda: All EAN-13 bar codes that begin with a “414” or “419” must have a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The EAN-13 bar code with the addenda is then transmitted as a single, concatenated bar code. If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

Don’t Require Addenda: If you have selected Require Addenda, and you want to disable this feature, scan Don’t Require Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

Default = Don’t Require Addenda.

EAN-13 Beginning with 434/439 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “434” or “439.” The following settings can be programmed:

Require Addenda: All EAN-13 bar codes that begin with a “434” or “439” must have a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The EAN-13 bar code with the addenda is then transmitted as a single, concatenated bar code. If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

Require 2 Digit Addenda

Require 5 Digit Addenda

Require 2 or 5 Digit Addenda

* Don’t Require Addenda

Require 2 Digit Addenda

Require 5 Digit Addenda

Require 2 or 5 Digit Addenda

6 - 37

Page 104: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Don’t Require Addenda: If you have selected Require Addenda, and you want to disable this feature, scan Don’t Require Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

Default = Don’t Require Addenda.

EAN-13 Beginning with 977 Addenda RequiredThis setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with “977.” The follow-ing settings can be programmed:

Require 2 Digit Addenda: All EAN-13 bar codes that begin with “977” must have a 2 digit addendum. The EAN-13 bar code with the 2 digit addendum is then transmitted as a single, concatenated bar code. If a 2 digit addendum is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit Addenda, and you want to disable this feature, scan Don’t Require 2 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

Default = Don’t Require 2 Digit Addenda.

EAN-13 Beginning with 978 Addenda RequiredThese settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “978.” The fol-lowing settings can be programmed:

Require 5 Digit Addenda: All EAN-13 bar codes that begin with “978” must have a 5 digit addendum. The EAN-13 bar code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

* Don’t Require Addenda

Require 2 Digit Addenda

Require 5 Digit Addenda

Require 2 or 5 Digit Addenda

* Don’t Require 2 Digit Addenda

Require 2 Digit Addenda

6 - 38

Page 105: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature, scan Don’t Require 5 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

Default = Don’t Require 5 Digit Addenda.

EAN-13 Beginning with 979 Addenda RequiredThese settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “979.” The fol-lowing settings can be programmed:

Require 5 Digit Addenda: All EAN-13 bar codes that begin with “979” must have a 5 digit addendum. The EAN-13 bar code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.

Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature, scan Don’t Require 5 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required.

Default = Don’t Require 5 Digit Addenda.

EAN/JAN-13 Addenda SeparatorWhen this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = Off.

Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code (page 6-27).

* Don’t Require 5 Digit Addenda

Require 5 Digit Addenda

* Don’t Require 5 Digit Addenda

Require 5 Digit Addenda

On

* Off

6 - 39

Page 106: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Addenda TimeoutYou can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A/EAN-13 with Extended Coupon Code or UPC-A Number System 4 Addenda Required. Set the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100.

Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.

EAN/JAN-13 RedundancyIf you are encountering errors when reading EAN/JAN-13 bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the EAN/JAN-13 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

ISBN Translate

When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off.

Convert ISBN to 13-DigitWhen translating EAN-13 codes to the ISBN format, you can convert the bar code to a 13 digit format by scanning the Convert to 13-Digit On bar code below. Default = Convert to 13-Digit Off.

Addenda Timeout

EAN/JAN-13 Redundancy

On

* Off

Convert to 13-Digit On

*Convert to 13-Digit Off

6 - 40

Page 107: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ISBN ReformatIn normal use, the first two or three digits of an EAN-13 bar code identify the country of origin. The country prefixes are 978 and 979. To reformat ISBN codes so the country prefix is dropped out, scan the Reformat On bar code below. Default = Reformat Off.

ISSN TranslateWhen On is scanned, EAN-13 977 Bookland symbols are translated into their equivalent 8-digit ISSN number format. For

example, 9770123456787 will be transmitted as 01234560. Default = Off.

ISSN ReformatWhen Reformat On is scanned, EAN-13 977 Bookland symbols are translated into their equivalent 8-digit ISSN num-ber format, with hyphens added to the output. For example, 9770123456787 will be transmitted as 0123-456-0. (You

must first scan ISSN On (page 6-41) before scanning Reformat On.) Default = Reformat Off.

Reformat On

*Reformat Off

On

* Off

Reformat On

* Reformat Off

6 - 41

Page 108: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EAN/JAN-8<Default All EAN/JAN-8 Settings>

EAN/JAN-8 On/Off

EAN/JAN-8 Check DigitThis selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.

Default = On.

EAN/JAN-8 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit

Addenda.

* On

Off

* On

Off

2 Digit Addenda On

* 2 Digit Addenda Off

5 Digit Addenda On

6 - 42

Page 109: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EAN/JAN-8 Addenda Required

When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda. Default = Not Required.

EAN/JAN-8 Addenda SeparatorWhen this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned

Off, there is no space. Default = Off.

Addenda TimeoutYou can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A/EAN-13 with Extended Coupon Code or UPC-A Number System 4 Addenda Required. Set the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100.

Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.

* 5 Digit Addenda Off

Required

* Not Required

On

* Off

Addenda Timeout

6 - 43

Page 110: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EAN/JAN-8 RedundancyIf you are encountering errors when reading EAN/JAN-8 bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the ba code. To adjust the redundancy, scan the EAN/JAN-8 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

MSI<Default All MSI Settings>

MSI On/Off

MSI Check CharacterDifferent types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit.

When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.

When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character(s), but will not transmit the check character(s) with the scanned data.

EAN/JAN-8 Redundancy

On

* Off

* Validate Type 10, but Don’t Transmit

Validate Type 10 and Transmit

6 - 44

Page 111: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

MSI RedundancyIf you are encountering errors when reading MSI bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the MSI Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

MSI Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

Validate 2 Type 10 Characters, but Don’t Transmit

Validate 2 Type 10 Characters and Transmit

Validate Type 10 then Type 11 Character, but Don’t Transmit

Validate Type 10 then Type 11 Character and Transmit

Disable MSI Check Characters

MSI Redundancy

Minimum Message Length

Maximum Message Length

6 - 45

Page 112: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Plessey Code< Default All Plessey Code Settings >

Plessey Code On/Off

Plessey Check CharacterNo Check Character indicates that the scanner reads and transmits bar code data with or without a check character.

When Check Character is set to Validate, but Don’t Transmit, the unit only reads Plessey bar codes printed with a check character, but will not transmit the check character with the scanned data.

When Check Character is set to Validate and Transmit, the scanner only reads Plessey bar codes printed with a check

character, and will transmit this character at the end of the scanned data. Default = No Check Character.

Plessey RedundancyIf you are encountering errors when reading Plessey bar codes, you may want to adjust the redundancy count. Redun-dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Plessey Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

On

* Off

* No Check Character

Validate, but Don’t Transmit

Validate and Transmit

Plessey Redundancy

6 - 46

Page 113: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Plessey Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

GS1 DataBar Omnidirectional< Default All GS1 DataBar Omnidirectional Settings >

GS1 DataBar Omnidirectional On/Off

GS1 DataBar Omnidirectional RedundancyIf you are encountering errors when reading GS1 DataBar Omnidirectional bar codes, you may want to adjust the redun-dancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the GS1 DataBar Omnidirectional Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Minimum Message Length

Maximum Message Length

* On

Off

GS1 DataBar Omnidirectional Redundancy

6 - 47

Page 114: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

GS1 DataBar Limited< Default All GS1 DataBar Limited Settings >

GS1 DataBar Limited On/Off

GS1 DataBar Limited RedundancyIf you are encountering errors when reading GS1 DataBar Limited bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redun-dancy, scan the GS1 DataBar Limited Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

* On

Off

GS1 DataBar Limited Redundancy

6 - 48

Page 115: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

GS1 DataBar Expanded< Default All GS1 DataBar Expanded Settings >

GS1 DataBar Expanded On/Off

GS1 DataBar Expanded RedundancyIf you are encountering errors when reading GS1 DataBar Expanded bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redun-dancy, scan the GS1 DataBar Expanded Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

GS1 DataBar Expanded Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

* On

Off

GS1 DataBar Expanded Redundancy

Minimum Message Length

Maximum Message Length

6 - 49

Page 116: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Trioptic CodeNote: If you are going to scan Code 32 Pharmaceutical codes (page 6-6), Trioptic Code must be off.

Trioptic Code is used for labeling magnetic storage media.

GS1 EmulationThe scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts GS1 data can be simplified since it only needs to recog-nize one data carrier type.)

If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Charts on page A-1).

If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be the GS1-DataBar AIM ID, ]em (see Symbology Charts on page A-1).

If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and UPC-E expansion is controlled by the UPC-E0 Expand (page 6-31) setting. If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Charts on page A-1).

If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted to EAN13 format.

Default = GS1 Emulation Off.

On

* Off

GS1-128 Emulation

GS1 DataBar Emulation

GS1 Code Expansion Off

EAN8 to EAN13 Conversion

* GS1 Emulation Off

6 - 50

Page 117: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

China Post (Hong Kong 2 of 5)<Default All China Post (Hong Kong 2 of 5) Settings>

China Post (Hong Kong 2 of 5) On/Off

China Post (Hong Kong 2 of 5) RedundancyIf you are encountering errors when reading China Post (Hong Kong 2 of 5) bar codes, you may want to adjust the redun-dancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the China Post (Hong Kong 2 of 5) Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

China Post (Hong Kong 2 of 5) Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.

On

* Off

China Post (Hong Kong 2 of 5) Redundancy

Minimum Message Length

Maximum Message Length

6 - 51

Page 118: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

6 - 52

Page 119: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

7

Utilities

To Add a Test Code I.D. Prefix to All SymbologiesThis selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Charts, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled.

Show Software RevisionScan the bar code below to output the current software revision, unit serial number, and other product information for the scan-ner.

Show Data FormatScan the bar code below to show current data format settings.

Test MenuWhen you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal.

Note: This feature should not be used during normal scanner operation.

TotalFreedomTotalFreedom is an open system architecture that makes it possible for you create applications that reside on your scanner. Decoding apps and Data Formatting apps can be created using TotalFreedom. For further information about TotalFreedom, go to our website at www.honeywellaidc.com.

Add Code I.D. Prefix toAll Symbologies (Temporary)

Show Software Revision

Data Format SettingsDFMBK3?.

On

* Off

7 - 1

Page 120: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Application Plug-Ins (Apps)Any apps that you are using can be turned off or on by scanning the following bar codes. Apps are stored in groups: Decoding, and Formatting. You can enable and disable these groups of apps by scanning that group’s On or Off bar code below. You can

also scan the List Apps bar code to output a list of all your apps.

Note: You must reset your device in order for the apps setting to take effect.

EZConfig-Scanning IntroductionEZConfig-Scanning provides a wide range of PC-based programming functions that can be performed on a scanner connected to your PC's COM port. EZConfig-Scanning allows you to download upgrades to the scanner's firmware, change programmed parameters, and create and print programming bar codes. Using EZConfig-Scanning, you can even save/open the program-ming parameters for a scanner. This saved file can be e-mailed or, if required, you can create a single bar code that contains all the customized programming parameters and mail or fax that bar code to any location. Users in other locations can scan the bar code to load in the customized programming.

To communicate with a scanner, EZConfig-Scanning requires that the PC have at least one available serial communication port, or a serial port emulation using a physical USB port. If you are using the serial port and RS232 cable, an external power supply is required.

EZConfig-Scanning OperationsThe EZConfig-Scanning software performs the following operations:

Scan DataScan Data allows you to scan bar codes and display the bar code data in a window. Scan Data lets you send serial commands to the scanner and receive scanner response that can be seen in the Scan Data window. The data dis-played in the Scan Data window can either be saved in a file or printed.

* Decoding Apps On

Decoding Apps Off

* Formatting Apps On

Formatting Apps Off

List Apps

7 - 2

Page 121: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ConfigureConfigure displays the programming and configuration data of the scanner. The scanner's programming and configu-ration data is grouped into different categories. Each category is displayed as a tree item under the "Configure" tree node in the application explorer. When one of these tree nodes is clicked, the right-hand side is loaded with the parameters' form belonging to that particular category. The "Configure" tree option has all the programming and con-figuration parameters specified for a scanner. You can set or modify these parameters as required. You can later write the modified settings to the scanner, or save them to a dcf file.

Installing EZConfig-Scanning from the WebNote: EZConfig-Scanning requires .NET software. If .NET is not installed on your PC, you will be prompted to install it

during the EZConfig-Scanning installation.

1. Access the Honeywell web site at www.honeywellaidc.com

2. Click on the Resources tab. Select Software.

3. Click on the dropdown for Select Product Number. Click on your product number.

4. Click on the listing for EZConfig-Scanning.

5. When prompted, select Save File, and save the files to the c:\windows\temp directory.

6. Once you have finished downloading the file, exit the web site.

7. Using Explorer, go to the c:\windows\temp file.

8. Double click on the Setup.exe file. Follow the screen prompts to install the EZConfig-Scanning program.

9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig-Scanning.

Resetting the Factory Defaults

If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want to restore the scan-ner to factory default settings, first scan the Remove Custom Defaults bar code, then scan Activate Defaults. This resets the scanner to the factory default settings.

The Menu Commands, beginning on page 8-4 list the factory default settings for each of the commands (indicated by an aster-isk (*) on the programming pages).

This selection erases all your settings and resets the scanner to the original factory defaults. It also disables all plugins.!

Remove Custom Defaults

Activate Defaults

7 - 3

Page 122: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

7 - 4

Page 123: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

8

Serial Programming Commands

The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming com-mand, refer to the corresponding programming bar code in this manual.

The device must be set to an RS232 interface (see page 2-1). The following commands can be sent via a PC COM port using terminal emulation software.

ConventionsThe following conventions are used for menu and query command descriptions:

parameterA label representing the actual value you should send as part of a command.

[option] An optional part of a command.

Data Alternatives in a command.

bold Names of menus, menu commands, buttons, dialog boxes, and windows that appear on the screen.

Menu Command SyntaxMenu commands have the following syntax (spaces have been used for clarity only):

Prefix [:Name:] Tag SubTag Data [, SubTag Data] [; Tag SubTag Data] […] Storage

Prefix Three ASCII characters: SYN M CR (ASCII 22,77,13).

Tag A 3 character case-insensitive field that identifies the desired menu command group. For example, all RS232 configuration settings are identified with a Tag of 232.

SubTag A 3 character case-insensitive field that identifies the desired menu command within the tag group. For example, the SubTag for the RS232 baud rate is BAD.

Data The new value for a menu setting, identified by the Tag and SubTag.

Storage A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table. Use the non-volatile table only for semi-permanent changes you want saved through a power cycle.

Query CommandsSeveral special characters can be used to query the device about its settings.

^ What is the default value for the setting(s).

? What is the device’s current value for the setting(s).

* What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.)

:Name: Field Usage (Optional)This command returns the query information from the scanner.

Tag Field UsageWhen a query is used in place of a Tag field, the query applies to the entire set of commands available for the particular storage table indicated by the Storage field of the command. In this case, the SubTag and Data fields should not be used because they are ignored by the device.

SubTag Field Usage When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the Tag field. In this case, the Data field should not be used because it is ignored by the device.

8 - 1

Page 124: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Data Field UsageWhen a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields.

Concatenation of Multiple CommandsMultiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the same Tag, then the new command sequence is separated with a comma (,) and only the SubTag and Data fields of the additional command are issued. If the additional command requires a different Tag field, the command is separated from previous commands by a semicolon (;).

ResponsesThe device responds to serial commands with one of three responses:

ACK Indicates a good command which has been processed.

ENQ Indicates an invalid Tag or SubTag command.

NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters.

When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command.

Examples of Query CommandsIn the following examples, a bracketed notation [ ] depicts a non-displayable response.

Example: What is the range of possible values for Codabar Coding Enable?

Enter: cbrena*.

Response: CBRENA0-1[ACK]

This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on).

Example: What is the default value for Codabar Coding Enable?

Enter: cbrena^.

Response: CBRENA1[ACK]

This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on.

Example: What is the device’s current setting for Codabar Coding Enable?

Enter: cbrena?.

Response: CBRENA1[ACK]

This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on.

Example: What are the device’s settings for all Codabar selections?

Enter: cbr?.

Response: CBRENA1[ACK],SSX0[ACK],CK20[ACK],CCT1[ACK],MIN2[ACK],MAX60[ACK],DFT[ACK].

This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required;concatenation (CCT) is set to 1, or Enabled;

8 - 2

Page 125: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value.

Serial Trigger CommandsYou can activate and deactivate the scanner with serial trigger commands. The trigger is activated and deactivated by sending the following commands:

Activate: SYN T CR

Deactivate: SYN U CR

The scanner scans until a bar code has been read, until the deactivate command is sent, or until the Read Time-out has been reached.

Read Time-OutUse this selection to set a time-out (in milliseconds) of the scanner’s trigger when using serial commands to trigger the scanner. Once the scanner has timed out, you can activate the scanner either by pressing the trigger or using a serial trig-ger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by scanning digits on the Programming Chart inside the back cover, then scanning Save. Default = 30,000 ms.

Resetting the Custom DefaultsIf you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings.

The charts on the following pages list the factory default settings for each of the commands (indicated by an asterisk (*) on the programming pages).

Read Time-Out

Activate Custom Defaults

8 - 3

Page 126: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Menu Commands

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

Product Default SettingsSetting Custom Defaults Set Custom Defaults MNUCDP 1-2

Save Custom Defaults MNUCDS 1-2

Resetting the Custom Defaults Activate Custom Defaults DEFALT 1-2

Programming the InterfacePlug and Play Codes RS232 Serial Port PAP232 2-1

OPOS Mode OPOS Mode PAPOPS 2-1

Plug and Play Codes Verifone Ruby Terminal PAPRBY 2-2

Gilbarco Terminal PAPGLB 2-2

Honeywell Bioptic Aux Port PAPBIO 2-2

Datalogic Magellan Aux Port PAPMAG 2-2

NCR Bioptic Aux Port PAPNCR 2-3

Wincor Nixdorf Terminal PAPWNX 2-3

Wincor Nixdorf Beetle PAPBTL 2-3

Baud Rate 300 BPS 232BAD0 2-4

600 BPS 232BAD1 2-4

1200 BPS 232BAD2 2-4

2400 BPS 232BAD3 2-4

4800 BPS 232BAD4 2-4

*9600 BPS 232BAD5 2-4

19200 BPS 232BAD6 2-4

38400 BPS 232BAD7 2-4

57600 BPS 232BAD8 2-4

115200 BPS 232BAD9 2-4

Word Length: Data Bits, Stop Bits, and Parity

7 Data, 1 Stop, Parity Even 232WRD3 2-5

7 Data, 1 Stop, Parity None 232WRD0 2-5

7 Data, 1 Stop, Parity Odd 232WRD6 2-5

7 Data, 2 Stop, Parity Even 232WRD4 2-5

7 Data, 2 Stop, Parity None 232WRD1 2-5

7 Data, 2 Stop, Parity Odd 232WRD7 2-5

8 Data, 1 Stop, Parity Even 232WRD5 2-5

*8 Data, 1 Stop, Parity None 232WRD2 2-5

8 Data, 1 Stop, Parity Odd 232WRD8 2-5

7 Data, 1 Stop, Parity Space 232WRD9 2-5

7 Data, 2 Stop, Parity Space 232WRD10 2-6

8 Data, 1 Stop, Parity Space 232WRD11 2-6

7 Data, 1 Stop, Parity Mark 232WRD12 2-6

7 Data, 2 Stop, Parity Mark 232WRD13 2-6

8 Data, 1 Stop, Parity Mark 232WRD14 2-6

8 - 4

Page 127: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

RS232 Handshaking *RTS/CTS Off 232CTS0 2-6

Flow Control, No Timeout 232CTS1 2-7

Character-Based Flow Control, No Timeout

232CTS7 2-7

Two-Direction Flow Control 232CTS2 2-7

Flow Control with Timeout 232CTS3 2-7

Character-Based Flow Control with Timeout

232CTS9 2-7

*RTS/CTS Off, RTS Inactive 232CTS10 2-6

RS232 Timeout 232DEL#### 2-7

*XON/XOFF Off 232XON0 2-7

XON/XOFF On 232XON1 2-7

*ACK/NAK Off 232ACK0 2-8

ACK/NAK On 232ACK1 2-8

Communication Timeout(Range 1-65535) *2000 ms

232DLK##### 2-8

Timeout Retries HSTRTY### 2-8

Communication Timeout Beeper - Off

HSTTOA0 2-8

*Communication Timeout Beeper - On

HSTTOA1 2-8

NAK Retries HSTRTN### 2-9

Support BEL/CAN in ACK/NAK BEL/CAN Mode On BELCAN1 2-9

*BEL/CAN Mode Off BELCAN0 2-9

RS232 Defaults Reset RS232 Defaults 232DFT 2-9

NCR Modifiers

NCR ACK/NAK *NCR ACK/NAK Off NCRACK0 2-9

NCR ACK/NAK On NCRACK1 2-9

Block Check Character *Transmit NCRBCC1 2-10

Don’t Transmit NCRBCC0 2-10

NCR Prefix/Suffix NCR Prefix NCRPR2## 2-10

NCR Suffix NCRSF2## 2-10

Transmit Prefix/Suffix NCRBCP1 2-10

*Don’t Transmit Prefix/Suffix NCRBCP0 2-10

NCR NOF (Not-on-File) Error On NCRRAZ1 2-11

*Off NCRRAZ0 2-11

Scanner-Bioptic Packet Mode *Packet Mode Off 232PKT0 2-11

Packet Mode On 232PKT2 2-11

Input/Output SelectionsPower Save Mode *Off PWRMOD0 3-1

Sleep Mode PWRMOD1 3-1

Hibernate Mode PWRMOD2 3-1

Power Save Mode Timeout Power Save Mode Timeout PWRLPT##### 3-1

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 5

Page 128: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Power Up Beeper Power Up Beeper Off - Scanner BEPPWR0 3-1

*Power Up Beeper On - Scanner BEPPWR1 3-2

Beep on BEL Character Beep on BEL On BELBEP1 3-2

*Beep on BEL Off BELBEP0 3-2

Beeper - Good Read Off BEPBEP0 3-2

*On BEPBEP1 3-2

Beeper Volume - Good Read Off BEPLVL0 3-2

Low BEPLVL1 3-2

Medium BEPLVL2 3-2

*High BEPLVL3 3-2

Beeper Pitch - Good Read (Frequency)

Low (1600) (min 90Hz) BEPFQ11600 3-3

*Medium (3200 Hz) BEPFQ13200 3-3

High (4200) (max 5000Hz) BEPFQ14200 3-3

Beeper - Transmit Order *Before Transmission BEPWHN1

After Transmission BEPWHN2

Vibrate - Good Read Vibrate - Good Read Off TFBGRD0 3-3

*Vibrate - Good Read On TFBGRD1 3-3

Vibrate Duration Duration(100 - 2,000 ms) *300

TFBDUR#### 3-4

Beeper Pitch - Error (Frequency) *Razz (100) (min 90Hz) BEPFQ2100 3-4

Medium (3250) BEPFQ23250 3-4

High (4200) (max 5000Hz) BEPFQ24200 3-4

Beeper Duration - Good Read *Normal Beep BEPBIP0 3-4

Short Beep BEPBIP1 3-4

Number of Beeps - Error *1 BEPERR3 3-5

Range 1 - 9 BEPERR# 3-5

Number of Beeps - Good Read *1 BEPRPT1 3-4

Range 1 - 9 BEPRPT# 3-4

Beeper Volume Max Beeper Volume Max PAPBLM 3-5

Laser Aimer - Scanning Pattern Pattern Off SCNGSI0 3-5

Laser Dot SCNGSI1 3-5

Blinking Dot SCNGSI2 3-5

3 Segment Line SCNGSI3 3-5

5 Segment Line SCNGSI4 3-6

*10 Segment Line SCNGSI5 3-6

Laser Aimer - Scanning Duration Range (0 - 65535) *0 SCNAIT##### 3-6

Laser Aimer - Good Read Pattern Off LASGSI0 3-6

3 Segment Line LASGSI3 3-6

5 Segment Line LASGSI4 3-6

*10 Segment Line LASGSI5 3-6

Laser Aimer - Good Read Duration Range (0 - 65535) *0 LASGIT##### 3-7

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 6

Page 129: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Aimer Delay 200 milliseconds SCNDLY200 3-7

400 milliseconds SCNDLY400 3-7

*Off (no delay) SCNDLY0 3-7

User-Specified Aimer Delay Range 0 - 4,000 ms SCNDLY#### 3-7

LED Indicators Red LED Off LEDFN10 3-7

Green LED Off LEDFN20 3-8

Red LED On with Good Scan LEDFN11 3-8

*Green LED On with Good Scan LEDFN21 3-8

*Red LED On with Laser LEDFN12 3-8

Green LED On with Laser LEDFN22 3-8

Red LED On when CodeGate Disabled

LEDFN14 3-8

Green LED On when CodeGate Disabled

LEDFN24 3-8

Red LED On with CTS LEDFN1128 3-8

Green LED On with CTS LEDFN2128 3-8

Good Read Delay *No Delay DLYGRD0 3-8

Short Delay (500 ms) DLYGRD500 3-8

Medium Delay (1000 ms) DLYGRD1000 3-9

Long Delay (1500 ms) DLYGRD1500 3-9

User-Specified Good Read Delay Range 0 - 30,000 ms DLYGRD##### 3-9

Out-of-Stand Settings Out-of-Stand Defaults AOSDFT 3-9

Presentation Mode Out-of-Stand PAPPM3 3-9

Manual Activation Mode Off Out-of-Stand

AOSMEN0 3-10

*Manual Activation Mode On Out-of-Stand

AOSMEN1 3-10

Do Not End Manual Activation After Good Read Out-of-Stand

AOSMGD0 3-10

*End Manual Activation After Good Read Out-of-Stand

AOSMGD1 3-10

Laser Timeout - Trigger Hold Out-of-Stand(Range 1 - 65525) *30,000 ms

AOSMPT##### 3-10

Laser Timeout - Trigger Release Out-of-Stand(Range 1 - 65525) *0 ms

AOSMRT##### 3-10

Reread Delay Short (500 ms) DLYRRD500 3-11

*Medium (750 ms) DLYRRD750 3-11

Long (1000 ms) DLYRRD1000 3-11

Extra Long (2000 ms) DLYRRD2000 3-11

User-Specified Reread Delay Range 0 - 30,000 ms DLYRRD##### 3-11

CodeGate CodeGate Off Out-of-Stand AOSCGD0. 3-11

*CodeGate On Out-of-Stand AOSCGD1. 3-11

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 7

Page 130: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Character Activation Mode *Off HSTCEN0 3-12

On HSTCEN1 3-12

Activation Character (Range 0-255) *18 [CAN]

HSTACH### 3-12

Do Not End Character Activation After Good Read

HSTCGD0 3-12

*End Character Activation After Good Read

HSTCGD1 3-12

Character Activation Timeout (Range 1 - 5000) *65,535 ms

HSTCDT###### 3-13

Character Deactivation Mode *Off HSTDEN0 3-13

On HSTDEN1 3-13

Deactivation Character (Range 0-255) *68 [h]

HSTDCH### 3-13

Centering Window Centering On DECWIN1 3-14

*Centering Off DECWIN0 3-14

Left of Centering Window (*40%) DECLFT### 3-14

Right of Centering Window (*60%) DECRGT### 3-14

Blinky Mode *Blinky Mode Off BLKMOD0 3-14

Blinky Mode On BLKMOD1 3-14

Blinky Always On/Continuous BLKMOD2 3-15

Laser Scan Angle Full Laser Beam Sweep LASANG0 3-15

Reduced Laser Beam Sweep LASANG1 3-15

Wide Laser Beam Sweep LASANG2 3-15

Decode Security Low PAPLS1 3-15

Low/Medium PAPLS2 3-15

Medium/High PAPLS3 3-15

High PAPLS4 3-15

Continuous Scan Mode Continuous Scan Mode PAPPM3 3-16

Output Sequence Editor Enter Sequence SEQBLK 3-18

Default Sequence SEQDFT 3-18

Sequence Timeout (Range 1 - 65535) *5000 ms SEQDLY##### 3-18

Sequence Match Beeper *On SEQBEP1 3-18

Off SEQBEP0 3-18

Partial Sequence Transmit Partial Sequence SEQTTS1 3-19

*Discard Partial Sequence SEQTTS0 3-19

Require Output Sequence Required SEQ_EN2 3-19

On/Not Required SEQ_EN1 3-19

*Off SEQ_EN0 3-19

Multiple Symbols On SHOTGN1 3-19

*Off SHOTGN0 3-19

No Read On SHWNRD1 3-19

*Off SHWNRD0 3-19

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 8

Page 131: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Prefix/Suffix SelectionsAdd CR Suffix to All Symbologies VSUFCR 4-2

Prefix Add Prefix PREBK2## 4-2

Clear One Prefix PRECL2 4-2

Clear All Prefixes PRECA2 4-2

Suffix Add Suffix SUFBK2## 4-2

Clear One Suffix SUFCL2 4-2

Clear All Suffixes SUFCA2 4-2

Function Code Transmit *Enable RMVFNC0 4-3

Disable RMVFNC1 4-3

Communication Check Character *None HSTXRC0 4-3

LRC Starts on 1st Character HSTXRC1 4-3

LRC Starts on 2nd Character HSTXRC2 4-3

Intercharacter Delay Range 0 - 1000 (5ms increments) DLYCHR## 4-4

User Specified Intercharacter Delay

Delay Length0 - 1000 (5ms increments)

DLYCRX## 4-4

Character to Trigger Delay DLY_XX## 4-4

Interfunction Delay Range 0 - 1000 (5ms increments) DLYFNC## 4-4

Intermessage Delay Range 0 - 1000 (5ms increments) DLYMSG## 4-5

Data Formatter SelectionsData Format Editor *Default Data Format (None) DFMDF3 5-1

Enter Data Format DFMBK3## 5-2

Clear One Data Format DFMCL3 5-2

Clear All Data Formats DFMCA3 5-2

Data Formatter Data Formatter Off DFM_EN0 5-11

*Data Formatter On,Not Required, Keep Prefix/Suffix

DFM_EN1 5-12

Data Format Required,Keep Prefix/Suffix

DFM_EN2 5-12

Data Formatter On,Not Required, Drop Prefix/Suffix

DFM_EN3 5-12

Data Format Required,Drop Prefix/Suffix

DFM_EN4 5-12

Data Format Non-Match Error Tone *Data Format Non-Match Error Tone On

DFMDEC0 5-12

Data Format Non-Match Error Tone Off

DFMDEC1 5-12

Primary/Alternate Data Formats Primary Data Format ALTFNM0 5-12

Data Format 1 ALTFNM1 5-13

Data Format 2 ALTFNM2 5-13

Data Format 3 ALTFNM3 5-13

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 9

Page 132: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Single Scan Data Format Change Single Scan-Primary Data Format

VSAF_0 5-13

Single Scan-Data Format 1 VSAF_1 5-13

Single Scan-Data Format 2 VSAF_2 5-13

Single Scan-Data Format 3 VSAF_3 5-13

SymbologiesAll Symbologies All Symbologies Off ALLENA0 6-1

All Symbologies On ALLENA1 6-1

Codabar Default All Codabar Settings

CBRDFT 6-2

Off CBRENA0 6-2

*On CBRENA1 6-2

Codabar Start/Stop Char. *Don’t Transmit CBRSSX0 6-2

Transmit CBRSSX1 6-2

Codabar Check Char. *No Check Char. CBRCK20 6-2

Validate Modulo 16, But Don’t Transmit

CBRCK21 6-2

Validate Modulo 16 and Transmit CBRCK22 6-3

Validate Modulo 7 CD, But Don’t Transmit

CBRCK23 6-3

Validate Modulo 7 CD and Transmit

CBRCK24 6-3

Validate CLSI, But Don’t Transmit CBRCK25 6-3

Validate CLSI and Transmit CBRCK26 6-3

Codabar Concatenation *Off CBRCCT0 6-3

On CBRCCT1 6-3

Require CBRCCT2 6-3

Concatenation Timeout DLYCCT 6-4

Codabar Redundancy Redundancy CBRVOT## 6-4

Codabar Message Length Minimum (1 - 80) *3 CBRMIN## 6-4

Maximum (1 - 80) *80 CBRMAX## 6-4

Code 39 Default All Code 39 Settings

C39DFT 6-5

Off C39ENA0 6-5

*On C39ENA1 6-5

Code 39 Start/Stop Char. *Don’t Transmit C39SSX0 6-5

Transmit C39SSX1 6-5

Code 39 Check Char. *No Check Char. C39CK20 6-5

Validate, But Don’t Transmit

C39CK21 6-5

Validate, and Transmit

C39CK22 6-5

Code 39 Redundancy Redundancy C39VOT## 6-6

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 10

Page 133: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 39 Message Length Minimum (1 - 80) *3 C39MIN## 6-6

Maximum (1 - 80) *80 C39MAX## 6-6

Code 39 Append *Off C39APP0 6-6

On C39APP1 6-6

Code 32 Pharmaceutical (PARAF) *Off C39B320 6-6

On C39B321 6-6

Code 39 Full ASCII *Off C39ASC0 6-7

On C39ASC1 6-7

Code 39 Code Page C39DCP 6-7

Interleaved 2 of 5 Default All Interleaved2 of 5 Settings

I25DFT 6-8

Off I25ENA0 6-8

*On I25ENA1 6-8

NULL Characters *Off I25NUL0 6-8

On I25NUL1 6-8

Interleaved 2 of 5 Check Digit *No Check Digit I25CK20 6-8

Validate, But Don’t Transmit

I25CK21 6-8

Validate, and Transmit I25CK22 6-8

Interleaved 2 of 5 Redundancy Redundancy I25VOT## 6-9

Interleaved 2 of 5 Message Length Minimum (2 - 80) *4 I25MIN## 6-9

Maximum (2 - 80) *80 I25MAX## 6-9

Matrix 2 of 5 Default All Matrix 2 of 5Settings

X25DFT 6-9

*Off X25ENA0 6-9

On X25ENA1 6-9

Matrix 2 of 5 Check Char. *No Check Char. X25CK20 6-9

Validate, But Don’t Transmit

X25CK21 6-9

Validate and Transmit X25CK22 6-9

Matrix 2 of 5 Redundancy Range (0 - 10) *0 X25VOT## 6-10

Matrix 2 of 5 Message Length Minimum (1 - 80) *3 X25MIN## 6-10

Maximum (1 - 80) *80 X25MAX## 6-10

NEC 2 of 5 Default All NEC2 of 5 Settings

N25DFT 6-11

*Off N25ENA0 6-11

On N25ENA1 6-11

NEC 2 of 5 Check Digit *No Check Char. N25CK20 6-11

Validate, But Don’t Transmit

N25CK21 6-11

Validate, and Transmit N25CK22 6-11

NEC 2 of 5 Redundancy Redundancy N25VOT## 6-11

NEC 2 of 5 Message Length Minimum (1 - 80) *3 N25MIN## 6-12

Maximum (1 - 80) *80 N25MAX## 6-12

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 11

Page 134: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Code 93 Default All Code 93 Settings

C93DFT 6-12

Off C93ENA0 6-12

*On C93ENA1 6-12

Code 93 Redundancy Redundancy C93VOT## 6-12

Code 93 Message Length Minimum (1 - 80) *3 C93MIN## 6-13

Maximum (1 - 80) *80 C93MAX## 6-13

Code 93 Append On C93APP1 6-13

*Off C93APP0 6-13

Code 93 Code Page Code 93 Code Page C93DCP 6-13

Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings

R25DFT 6-14

*Off R25ENA0 6-14

On R25ENA1 6-14

Straight 2 of 5 Redundancy Redundancy R25VOT## 6-14

Straight 2 of 5 Industrial Message Length

Minimum (1 - 80) *3 R25MIN## 6-14

Maximum (1 - 80) *80 R25MAX## 6-14

Straight 2 of 5 IATA Default All Straight 2 of 5 IATASettings

A25DFT 6-15

Straight 2 of 5 IATA *Off A25ENA0 6-15

On A25ENA1 6-15

Straight 2 of 5 IATA Redundancy Redundancy A25VOT## 6-15

Straight 2 of 5 IATA Message Length

Minimum (1 - 80) *15 A25MIN## 6-15

Maximum (1 - 80) *13 A25MAX## 6-15

Code 11 Default All Code 11 Settings

C11DFT 6-16

*Off C11ENA0 6-16

On C11ENA1 6-16

Code 11 Check Digits Required 1 Check Digit C11CK20 6-16

*2 Check Digits C11CK21 6-16

Code 11 Redundancy Redundancy C11VOT## 6-16

Code 11 Message Length Minimum (1 - 80) *3 C11MIN## 6-16

Maximum (1 - 80) *80 C11MAX## 6-16

Code 128 Default All Code 128Settings

128DFT 6-17

Off 128ENA0 6-17

*On 128ENA1 6-17

128 Group Separator Output *Off 128GSE0 6-17

On 128GSE1 6-17

Code 128 Redundancy Redundancy 128VOT## 6-17

Code 128 Message Length Minimum (0 - 80) *3 128MIN## 6-18

Maximum (0 - 80) *80 128MAX## 6-18

Code 128 Append *On 128APP1 6-18

Off 128APP0 6-18

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 12

Page 135: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ISBT 128 *Off ISBENA0 6-18

On ISBENA1 6-18

Concatenation Timeout DLYCCT 6-19

ISBT128 Predefined Concatenation Sequences

* Donation ID Number (001)and ABO/RhD Blood Groups (002)

ISBPCS0 6-19

Donation ID Number (001) andDonor ID Number (019)

ISBPCS1 6-19

Donation ID Number (001) and Confidential Unit Exclusion Status

ISBPCS2 6-19

Product Code (003) and Expiration Date (Form 1)

ISBPCS3 6-19

Product Code (003) and Expiration Date (Form 2)

ISBPCS4 6-19

Product Code (003) and Expiration Date (Form 3)

ISBPCS5 6-19

Product Code (003) and Expiration Date (Form 4)

ISBPCS6 6-19

ISBT 128 Predefined Concatenation Sequences On/Off

*Off ISBPCE0 6-20

Allow Predefined Sequence ISBPCE1 6-20

Require Predefined Sequence ISBPCE2 6-20

ISBT 128 User-Defined Concatenation Sequences

1st Left Identifier (0-255) *0 ISBUL1## 6-21

2nd Left Identifier (0-255) *0 ISBUL2## 6-21

1st Right Identifier (0-255) *0 ISBUR1## 6-21

2nd Right Identifier (0-255) *0 ISBUR2## 6-21

ISBT 128 User-Defined Concatenation Sequences On/Off

*Off ISBUCE0 6-21

Allow User-Defined Sequence ISBUCE1 6-22

Require User-Defined Sequence ISBUCE2 6-22

Content Verification *Off ISBXM00 6-22

On ISBXM01 6-22

Transmit Identifiers Off ISBXM10 6-22

*On ISBXM11 6-22

Flag Digit Conversion *Off ISBXM20 6-22

On ISBXM21 6-22

GS1-128 Default All GS1-128 Settings GS1DFT 6-23

*On GS1ENA1 6-23

Off GS1ENA0 6-23

GS1-128 Application Identifier Parsing

*Off GS1EMU0 6-23

Transmit Without Identifiers GS1EMU1 6-23

Transmit With Identifiers GS1EMU2 6-23

GS1-128 Redundancy Redundancy GS1VOT## 6-23

GS1-128 Message Length Minimum (1 - 80) *3 GS1MIN## 6-24

Maximum (1 - 80) *80 GS1MAX## 6-24

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 13

Page 136: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Telepen Default All TelepenSettings

TELDFT 6-24

*Off TELENA0 6-24

On TELENA1 6-24

Telepen Output *AIM Telepen Output TELOLD0 6-24

Original Telepen Output TELOLD1 6-24

Telepen Redundancy Redundancy TELVOT## 6-24

Telepen Message Length Minimum (1 - 80) *3 TELMIN## 6-25

Maximum (1 - 80) *80 TELMAX## 6-25

UPC-A Default All UPC-A Settings

UPADFT 6-25

Off UPBENA0 6-25

*On UPBENA1 6-25

UPC-A Check Digit Off UPACKX0 6-25

*On UPACKX1 6-25

UPC-A Number System Off UPANSX0 6-26

*On UPANSX1 6-26

UPC-A Addenda *2 Digit Addenda Off UPAAD20 6-26

2 Digit Addenda On UPAAD21 6-26

*5 Digit Addenda Off UPAAD50 6-26

5 Digit Addenda On UPAAD51 6-26

UPC-A Addenda Required *Not Required UPAARQ0 6-26

Required UPAARQ1 6-26

UPC-A Addenda Separator

Off UPAADS0 6-27

*On UPAADS1 6-27

Addenda Timeout Range (0 - 65535) *100 DLYADD##### 6-27

UPC-A Redundancy Redundancy UPAVOT## 6-27

UPC-A/EAN-13 with Extended Coupon Code

*Off CPNENA0 6-27

Allow Concatenation CPNENA1 6-27

Require Concatenation CPNENA2 6-27

UPC-A/Code 128 Coupon Code Output

* Multiple Code Output CPNSTY0 6-28

Single Code Output CPNSTY1 6-28

UPC-A Number System 4 Addenda Required

* Don’t Require Coupon Code ARQSY40 6-28

Require Coupon Code ARQSY41 6-28

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 14

Page 137: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

UPC-A Number System 5 Addenda Required

* Don’t Require Coupon Code/Addenda

ARQSY50 6-29

Require 2 Digit Addenda ARQSY51 6-29

Require 5 Digit Addenda ARQSY52 6-29

Require 2 or 5 Digit Addenda ARQSY53 6-29

Require Coupon Code ARQSY54 6-29

Require Coupon Code or 2 Digit Addenda

ARQSY55 6-29

Require Coupon Code or 5 Digit Addenda

ARQSY56 6-29

Require Coupon Code, 2 Digit Addenda, or 5 Digit Addenda

ARQSY57 6-29

Coupon GS1 DataBar Output GS1 Output Off CPNGS10 6-30

GS1 Output On CPNGS11 6-30

Addenda Timeout Range (0 - 65535) *100 DLYADD##### 6-30

UPC-E0 Default All UPC-ESettings

UPEDFT 6-31

Off UPEEN00 6-31

*On UPEEN01 6-31

UPC-E0 Expand *Off UPEEXP0 6-31

On UPEEXP1 6-31

UPC-E0 Number System *On UPEEXN1 6-31

Off UPEEXN0 6-31

UPC-E0 Addenda Required Required UPEARQ1 6-32

*Not Required UPEARQ0 6-32

Addenda Timeout Range (0 - 65535) *100 DLYADD##### 6-30

UPC-E0 Addenda Separator On UPEADS1 6-32

*Off UPEADS0 6-32

UPC-E0 Check Digit *Off UPECKX0 6-32

On UPECKX1 6-32

UPC-E0 Leading Zero *Off UPENSX0 6-33

On UPENSX1 6-33

UPC-E0 Addenda 2 Digit Addenda On UPEAD21 6-33

*2 Digit Addenda Off UPEAD20 6-33

5 Digit Addenda On UPEAD51 6-33

*5 Digit Addenda Off UPEAD50 6-33

UPC-E0 Redundancy Redundancy UPEVOT## 6-33

EAN/JAN-13 Default All EAN/JAN Settings

E13DFT 6-34

Off E13ENA0 6-34

*On E13ENA1 6-34

Convert UPC-A to EAN-13 UPC-A Converted to EAN-13 UPAENA0 6-34

* Do not Convert UPC-A UPAENA1 6-34

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 15

Page 138: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EAN/JAN-13 Check Digit Off E13CKX0 6-34

*On E13CKX1 6-34

EAN/JAN-13 2 Digit Addenda 2 Digit Addenda On E13AD21 6-35

*2 Digit Addenda Off E13AD20 6-35

5 Digit Addenda On E13AD51 6-35

*5 Digit Addenda Off E13AD50 6-35

EAN/JAN-13 Addenda Required *Not Required E13ARQ0 6-35

Required E13ARQ1 6-35

EAN-13 Beginning with 2 Addenda Required

* Don’t Require 2 Digit Addenda ARQSY20 6-36

Require 2 Digit Addenda ARQSY21 6-36

EAN-13 Beginning with 290 Addenda Required

* Don’t Require 5 Digit Addenda ARQ2900 6-36

Require 5 Digit Addenda ARQ2901 6-36

EAN-13 Beginning with 378/379 Addenda Required

* Don’t Require Addenda ARQ3780 6-37

Require 2 Digit Addenda ARQ3781 6-37

Require 5 Digit Addenda ARQ3782 6-37

Require 2 or 5 Digit Addenda ARQ3783 6-37

EAN-13 Beginning with 414/419 Addenda Required

* Don’t Require Addenda ARQ4140 6-37

Require 2 Digit Addenda ARQ4141 6-37

Require 5 Digit Addenda ARQ4142 6-37

Require 2 or 5 Digit Addenda ARQ4143 6-37

EAN-13 Beginning with 434/439 Addenda Required

* Don’t Require Addenda ARQ4340 6-38

Require 2 Digit Addenda ARQ4341 6-38

Require 5 Digit Addenda ARQ4342 6-38

Require 2 or 5 Digit Addenda ARQ4343 6-38

EAN-13 Beginning with 977 Addenda Required

* Don’t Require 2 Digit Addenda ARQ9770 6-38

Require 2 Digit Addenda ARQ9771 6-38

EAN-13 Beginning with 978 Addenda Required

* Don’t Require 5 Digit Addenda ARQ9780 6-39

Require 5 Digit Addenda ARQ9781 6-39

EAN-13 Beginning with 979 Addenda Required

* Don’t Require 5 Digit Addenda ARQ9790 6-39

Require 5 Digit Addenda ARQ9791 6-39

EAN/JAN-13 Addenda Separator

*Off E13ADS0 6-39

On E13ADS1 6-39

Addenda Timeout Range (0 - 65535) *100 DLYADD##### 6-40

EAN/JAN-13 Redundancy Redundancy E13VOT## 6-40

ISBN Translate *Off E13ISB0 6-40

On E13ISB1 6-40

Convert to 13-Digit On E13I131 6-40

*Convert to 13-Digit Off E13I130 6-40

Reformat On E13IBR1 6-41

*Reformat Off E13IBR0 6-41

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 16

Page 139: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ISSN Translate *Off E13ISS0 6-41

On E13ISS1 6-41

Reformat On E13ISR1 6-41

*Reformat Off E13ISR0 6-41

EAN/JAN-8 Default All EAN/JAN 8 Settings

EA8DFT 6-42

Off EA8ENA0 6-42

*On EA8ENA1 6-42

EAN/JAN-8 Check Digit Off EA8CKX0 6-42

*On EA8CKX1 6-42

EAN/JAN-8 Addenda *2 Digit Addenda Off EA8AD20 6-42

2 Digit Addenda On EA8AD21 6-42

*5 Digit Addenda Off EA8AD50 6-42

5 Digit Addenda On EA8AD51 6-42

EAN/JAN-8 Addenda Required *Not Required EA8ARQ0 6-43

Required EA8ARQ1 6-43

EAN/JAN-8 Addenda Separator

*Off EA8ADS0 6-43

On EA8ADS1 6-43

Addenda Timeout Range (0 - 65535) *100 DLYADD##### 6-43

EAN/JAN-8 Redundancy Redundancy EA8VOT## 6-43

MSI Default All MSI Settings MSIDFT 6-44

*Off MSIENA0 6-44

On MSIENA1 6-44

MSI Check Character *Validate Type 10, but Don’t Transmit

MSICHK0 6-44

Validate Type 10 and Transmit

MSICHK1 6-44

Validate 2 Type 10 Chars, but Don’t Transmit

MSICHK2 6-44

Validate 2 Type 10 Chars and Transmit

MSICHK3 6-45

Validate Type 10 then Type 11 Char, but Don’t Transmit

MSICHK4 6-45

Validate Type 10 then Type 11 Char and Transmit

MSICHK5 6-45

Disable MSI Check Characters MSICHK6 6-45

MSI Redundancy Redundancy MSIVOT## 6-45

MSI Message Length Minimum (1 - 80) *3 MSIMIN## 6-45

Maximum (1 - 80) *80 MSIMAX## 6-45

Plessey Code Default All Plessey Code Settings

PLSDFT 6-46

Off PLSENA0 6-46

*On PLSENA1 6-46

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 17

Page 140: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Plessey Check Char. *No Check Char. PLSCHK0 6-46

Validate, But Don’t Transmit

PLSCHK1 6-46

Validate, and Transmit

PLSCHK2 6-46

Plessey Redundancy Range (0 - 10) *0 PLSVOT## 6-46

Plessey Message Length Minimum (1 - 80) *3 PLSMIN## 6-47

Maximum (1 - 80) *80 PLSMAX## 6-47

GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings

RSSDFT 6-47

Off RSSENA0 6-47

*On RSSENA1 6-47

GS1 DataBar Omnidirectional Redundancy

Redundancy RSSVOT## 6-47

GS1 DataBar Limited Default All GS1 DataBar Limited Settings

RSLDFT 6-48

Off RSLENA0 6-48

*On RSLENA1 6-48

GS1 DataBar Limited Redundancy Redundancy RSLVOT## 6-48

GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings

RSEDFT 6-49

Off RSEENA0 6-49

*On RSEENA1 6-49

GS1 DataBar Expanded Redundancy

Redundancy RSEVOT## 6-49

GS1 DataBar Expanded Msg. Length

Minimum (1 - 80) *3 RSEMIN## 6-49

Maximum (1 - 80) *80 RSEMAX## 6-49

Trioptic Code *Off TRIENA0 6-50

On TRIENA1 6-50

China Post (Hong Kong 2 of 5) Default All China Post (Hong Kong 2 of 5) Settings

CPCDFT 6-51

*Off CPCENA0 6-51

On CPCENA1 6-51

China Post (Hong Kong 2 of 5) Redundancy

Redundancy CPCVOT## 6-51

China Post (Hong Kong 2 of 5) Msg. Length

Minimum (1 - 80) *3 CPCMIN## 6-51

Maximum (1 - 80) *80 CPCMAX## 6-51

UtilitiesAdd Code I.D. Prefix to All Symbologies (Temporary) PRECA2,BK2995C80! 7-1

Show Software Revision REVINF 7-1

Show Data Format DFMBK3? 7-1

Test Menu On TSTMNU1 7-1

*Off TSTMNU0 7-1

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 18

Page 141: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Application Plug-Ins (Apps) *Decoding Apps On PLGDCE1 7-2

Decoding Apps Off PLGDCE0 7-2

*Formatting Apps On PLGFOE1 7-2

Formatting Apps Off PLGFOE0 7-2

List Apps PLGINF 7-2

Resetting the Factory Defaults Remove Custom Defaults DEFOVR 7-3

Activate Defaults DEFALT 7-3

Serial Programming CommandsSerial Trigger Mode Read Time-Out

(0 - 300,000 ms) *30,000TRGSTO#### 8-3

Selection Setting* Indicates default

Serial Command# Indicates a numeric entry

Page

8 - 19

Page 142: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

8 - 20

Page 143: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

9

Product Specifications

Granit 1280i Industrial Corded Scanner Product Specifications

Parameter Specification

Dimensions (Typical):

Height 7.7 in. (19.45cm)

Length 5.2 in. (13.31cm)

Width 2.9 in. (7.5cm)

Weight 11.8 oz. (335g)

Scan Line:

Peak Wavelength Laser 650nmIEC 60825-1: “Class 2”

Optical Power Laser <1mW

Skew Angle +65°

Pitch Angle +65°

Voltage Requirements 4 - 5.5 VDC at input connector

Current Draw @5VDCScanning Standby360mA, 1.8W 150mA, 0.75W

Power Supply Noise Rejection Maximum 100mV peak to peak, 10 to 100 kHz

Temperature Ranges:

Operating -22F to +122F (-30C to 50C)

Operating in Presentation Mode -22F to +104F (-30C to 40C)

Storage -40F to +158F (-40C to 70C)

Humidity 0 to 95% non-condensing

Mechanical Drop Operational after 50 drops from 6.6 feet (2m) to concrete at 23°, -30°, and 50°C

Vibration Complies with MIL-STD-810G, Method 514.6, Annex C

ESD ToleranceUp to 20kV direct airUp to 8 kV indirect coupling plane

Sealant Rating IP65

9 - 1

Page 144: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Depth of Field Charts

Typical Performance

Guaranteed Performance

Focus Near Distance Far Distance

Paper

7.5 milin. 3.5 18.5

cm 8.9 47

10 milin. 4 32.5

cm 10.2 82.6

15 milin. 4 62.5

cm 10.2 158.8

20 milin. 4.5 83.4

cm 11.4 211.8

55 milin. 13.5 178.5

cm 34.3 453.4

100 milin. 36.5 183.5

cm 92.7 466.1

Retro-reflective

70 milin. 23.5 468.9

cm 59.7 11.9m

100 milin. 38.5 649.6

cm 97.8 16.5m

Minimum Resolution: 5 mil

Focus Near Distance Far Distance

Paper

7.5 milin. 4.5 13.5

cm 11.4 34.3

10 milin. 4.5 28.5

cm 11.4 72.4

15 milin. 5.5 48.5

cm 14 123.2

20 milin. 5.5 68.5

cm 14 174

55 milin. 15.5 153.5

cm 39.4 389.9

100 milin. 43.5 178.5

cm 110.5 453.4

Retro-reflective

70 milin. 28.5 403.5

cm 72.4 10.2m

100 milin. 43.5 556.3

cm 110.5 14.1m

9 - 2

Page 145: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Minimum Resolution: 5 mil

Focus Near Distance Far Distance

9 - 3

Page 146: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Standard Connector Pinouts

Serial Output10 Pin RJ41 Modular Plug - connects to the scanner

1 Cable shield2 Cable select3 Supply ground4 Transmit data5 Receive data - serial data to scanner6 CTS7 +5V power8 RTS910

9 - 4

Page 147: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

10

Maintenance

RepairsRepairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center (see Customer Support on page 11-1).

MaintenanceYour device provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation:

Cleaning the ScannerThe scanner’s housing may be cleaned with a soft cloth or tissue dampened with water (or a mild detergent-water solution.) If a detergent solution is used, rinse with a clean tissue dampened with water only.

Cleaning the WindowReading performance may degrade if the scanner’s window is not clean. If the window is visibly dirty, or if the scanner isn’t operating well, clean the window with gentle dish soap and water.

Inspecting Cords and ConnectorsInspect the interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with scanner operation. Contact your distributor for information about cable replacement. Cable replacement instructions are on page 10-1.

Replacing CablesThe standard interface cable is attached to the scanner with an 10-pin modular connector. When properly seated, the connec-tor is held in the scanner’s handle by a flexible retention tab. The interface cable is designed to be field replaceable.

• Order replacement cables from Honeywell or from an authorized distributor.• When ordering a replacement cable, specify the cable part number of the original interface cable.

Do not submerge the scanner in water. The scanner’s housing is not watertight.

Do not use abrasive wipes or tissues on the scanner’s window – abrasive wipes may scratch the window. Never use solvents (e.g., acetone) on the housing or window –

solvents may damage the finish or the window.

! Caution:Do not submerge the scanner in water. The scanner’s

housing is not watertight.

Do not use abrasive wipes or tissues on the scanner’s window – abrasive wipes may scratch the window. Never use solvents (e.g., acetone) on the housing or window –

solvents may damage the finish or the window.

10 - 1

Page 148: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Replacing an Interface Cable1. Turn the power to the host system OFF.

2. Disconnect the scanner’s cable from the terminal or computer.

3. Unscrew the locking plate on the bottom of the scanner.

4. Slide the locking plate away from the connector and pull the cable out of the scanner.

5. Replace with the new cable.

6. Insert the connector into the opening and press firmly.

7. Slide the locking plate over the base of the connector to secure the cable, and screw the plate into place.

TroubleshootingThe scanner automatically performs self-tests whenever you turn it on. If your scanner is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem.

Is the power on? Is the aimer on?

If the aimer isn’t illuminated, check that:

• The cable is connected properly.• The host system power is on (if external power isn’t used).• The trigger works.

Is the scanner having trouble reading your symbols?

If the scanner isn’t reading symbols well, check that the symbols:

• Aren’t smeared, rough, scratched, or exhibiting voids.• Aren’t coated with frost or water droplets on the surface.• Are enabled in the scanner or in the decoder to which the scanner connects.

Is the bar code displayed but not entered?

The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example).

• You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you need (such as “CR”) to enter the data into your application. Refer to Prefix/Suffix Overview on page 4-1 for further information.

Does the scanner read the bar code incorrectly?

If the scanner reads a bar code, but the data is not displayed correctly on the host screen:

• The scanner may not be programmed for the appropriate terminal interface. For example, you scan “12345” and the host displays “@es%.”

Reprogram the scanner with the correct Plug and Play bar code. See Programming the Interface beginning on page 2-1.

• The scanner may not be programmed to output your bar code data properly.For example, you scan “12345” and the host displays “A12345B.”

Reprogram the scanner with the proper symbology selections. See Chapter 6.

The scanner won’t read your bar code at all.

1. Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar code is readable.Verify that your bar code symbology is enabled (see Chapter 6).

2. If the scanner still can’t read the sample bar codes, scan All Symbologies On, page 6-1.

If you aren’t sure what programming options have been set in the scanner, or if you want the factory default settings restored, refer to Resetting the Factory Defaults on page 7-3.

10 - 2

Page 149: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

11

Customer Support

Technical AssistanceIf you need assistance installing or troubleshooting your device, please contact us by using one of the methods below:

Knowledge Base: www.hsmknowledgebase.com

Our Knowledge Base provides thousands of immediate solutions. If the Knowledge Base cannot help, our Technical Support Portal (see below) provides an easy way to report your problem or ask your question.

Technical Support Portal: www.hsmsupportportal.com

The Technical Support Portal not only allows you to report your problem, but it also provides immediate solutions to your techni-cal issues by searching our Knowledge Base. With the Portal, you can submit and track your questions online and send and receive attachments.

Web form: www.hsmcontactsupport.com

You can contact our technical support team directly by filling out our online support form. Enter your contact details and the description of the question/problem.

Telephone: www.honeywellaidc.com/locations

For our latest contact information, please check our website at the link above.

Product Service and RepairHoneywell International Inc. provides service for all of its products through service centers throughout the world. To obtain war-ranty or non-warranty service, please visit www.honeywellaidc.com and select Support > Contact Service and Repair to see your region's instructions on how to obtain a Return Material Authorization number (RMA #). You should do this prior to return-ing the product.

Limited Warranty

Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper maintenance, service, and cleaning schedule; or (iii) damaged as a result of (A) modification or alteration by the purchaser or other party, (B) excessive voltage or current supplied to or drawn from the interface connections, (C) static electricity or electro-static discharge, (D) operation under conditions beyond the specified operating parameters, or (E) repair or service of the prod-uct by anyone other than HII or its authorized representatives.

This warranty shall extend from the time of shipment for the duration published by HII for the product at the time of purchase ("Warranty Period"). Any defective product must be returned (at purchaser’s expense) during the Warranty Period to HII factory or authorized service center for inspection. No product will be accepted by HII without a Return Materials Authorization, which may be obtained by contacting HII. In the event that the product is returned to HII or its authorized service center within the Warranty Period and HII determines to its satisfaction that the product is defective due to defects in materials or workmanship, HII, at its sole option, will either repair or replace the product without charge, except for return shipping to HII.

EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

HII’S RESPONSIBILITY AND PURCHASER’S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO EVENT SHALL HII BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER (WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT

11 - 1

Page 150: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

EVEN WHEN HII MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSE-QUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.

All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unen-forceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty. This includes but is not limited to: cables, power supplies, cradles, and docking stations. HII extends these warranties only to the first end-users of the products. These warranties are non-transferable.

The duration of the limited warranty for the Granit 1280i scanner is three (3) years.

11 - 2

Page 151: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

A

Reference Charts

Symbology ChartsNote: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM

modifier character details.

Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry.

Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on page 5-1 for information about using Code ID and AIM ID.

Linear Symbologies

AIM Honeywell

Symbology IDPossible modifiers (m)

ID Hex

All Symbologies 99

Codabar ]Fm 0-1 a 61

Code 11 ]H3 h 68

Code 128 ]Cm 0, 1, 2, 4 j 6A

Code 32 Pharmaceutical (PARAF) ]X0 < 3C

Code 39 (supports Full ASCII mode) ]Am 0, 1, 3, 4, 5, 7 b 62

TCIF Linked Code 39 (TLC39) ]L2 T 54

Code 93 and 93i ]Gm 0-9, A-Z, a-m

i 69

EAN ]Em 0, 1, 3, 4 d 64

EAN-13 (including Bookland EAN) ]E0 d 64

EAN-13 with Add-On ]E3 d 64

EAN-13 with Extended Coupon Code ]E3 d 64

EAN-8 ]E4 D 44

EAN-8 with Add-On ]E3 D 44

GS1

GS1 DataBar ]em 0 y 79

GS1 DataBar Limited ]em 7B

GS1 DataBar Expanded ]em 7D

GS1-128 ]C1 I 49

2 of 5

China Post (Hong Kong 2 of 5) ]X0 Q 51

Interleaved 2 of 5 ]Im 0, 1, 3 e 65

Matrix 2 of 5 ]X0 m 6D

NEC 2 of 5 ]X0 Y 59

Straight 2 of 5 IATA ]Rm 0, 1, 3 f 66

Straight 2 of 5 Industrial ]S0 f 66

MSI ]Mm 0, 1 g 67

Telepen ]Bm t 74

UPC 0, 1, 2, 3, 8, 9, A, B, C

A - 1

Page 152: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Postal Symbologies

ASCII Conversion Chart (Code Page 1252)In keyboard applications, ASCII Control Characters can be represented in 3 different ways, as shown below. The CTRL+X func-tion is OS and application dependent. The following table lists some commonly used Microsoft functionality. This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings.

UPC-A ]E0 c 63

UPC-A with Add-On ]E3 c 63

UPC-A with Extended Coupon Code ]E3 c 63

UPC-E ]E0 E 45

UPC-E with Add-On ]E3 E 45

UPC-E1 ]X0 E 45

Add Honeywell Code ID 5C80

Add AIM Code ID 5C81

Add Backslash 5C5C

Batch mode quantity 5 35

AIM Honeywell

Symbology IDPossible modifiers (m)

ID Hex

All Symbologies 99

China Post ]X0 Q 51

Non-printable ASCII control characters

Keyboard Control + ASCII (CTRL+X) Mode

Control + X Mode Off (KBDCAS0)

Windows Mode Control + X Mode On (KBDCAS2)

DEC HEX Char CTRL + X CTRL + X function

0 00 NUL Reserved CTRL+ @

1 01 SOH NP Enter CTRL+ A Select all

2 02 STX Caps Lock CTRL+ B Bold

3 03 ETX ALT Make CTRL+ C Copy

4 04 EOT ALT Break CTRL+ D Bookmark

5 05 ENQ CTRL Make CTRL+ E Center

6 06 ACK CTRL Break CTRL+ F Find

7 07 BEL Enter / Ret CTRL+ G

8 08 BS (Apple Make) CTRL+ H History

9 09 HT Tab CTRL+ I Italic

10 0A LF (Apple Break) CTRL+ J Justify

11 0B VT Tab CTRL+ K hyperlink

12 0C FF Delete CTRL+ Llist, left align

13 0D CR Enter / Ret CTRL+ M

AIM Honeywell

Symbology IDPossible modifiers (m)

ID Hex

A - 2

Page 153: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Lower ASCII Reference Table

Windows Code page 1252 and lower ASCII use the same characters. Note:

14 0E SO Insert CTRL+ N New

15 0F SI ESC CTRL+ O Open

16 10 DLE F11 CTRL+ P Print

17 11 DC1 Home CTRL+ Q Quit

18 12 DC2 PrtScn CTRL+ R

19 13 DC3 Backspace CTRL+ S Save

20 14 DC4 Back Tab CTRL+ T

21 15 NAK F12 CTRL+ U

22 16 SYN F1 CTRL+ V Paste

23 17 ETB F2 CTRL+ W

24 18 CAN F3 CTRL+ X

25 19 EM F4 CTRL+ Y 26 1A SUB F5 CTRL+ Z 27 1B ESC F6 CTRL+ [ 28 1C FS F7 CTRL+ \ 29 1D GS F8 CTRL+ ] 30 1E RS F9 CTRL+ ^ 31 1F US F10 CTRL+ - 127 7F NP Enter

Printable CharactersDEC HEX Character DEC HEX Character DEC HEX Character

32 20 <SPACE> 64 40 @ 96 60 `33 21 ! 65 41 A 97 61 a34 22 " 66 42 B 98 62 b35 23 # 67 43 C 99 63 c36 24 $ 68 44 D 100 64 d37 25 % 69 45 E 101 65 e38 26 & 70 46 F 102 66 f39 27 ' 71 47 G 103 67 g40 28 ( 72 48 H 104 68 h41 29 ) 73 49 I 105 69 i42 2A * 74 4A J 106 6A j43 2B + 75 4B K 107 6B k44 2C , 76 4C L 108 6C l45 2D - 77 4D M 109 6D m46 2E . 78 4E N 110 6E n47 2F / 79 4F O 111 6F o48 30 0 80 50 P 112 70 p49 31 1 81 51 Q 113 71 q50 32 2 82 52 R 114 72 r

Non-printable ASCII control characters

Keyboard Control + ASCII (CTRL+X) Mode

Control + X Mode Off (KBDCAS0)

Windows Mode Control + X Mode On (KBDCAS2)

DEC HEX Char CTRL + X CTRL + X function

A - 3

Page 154: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

51 33 3 83 53 S 115 73 s52 34 4 84 54 T 116 74 t53 35 5 85 55 U 117 75 u54 36 6 86 56 V 118 76 v55 37 7 87 57 W 119 77 w56 38 8 88 58 X 120 78 x57 39 9 89 59 Y 121 79 y58 3A : 90 5A Z 122 7A z59 3B ; 91 5B [ 123 7B 60 3C < 92 5C \ 124 7C |61 3D = 93 5D ] 125 7D 62 3E > 94 5E ^ 126 7E ~63 3F ? 95 5F _ 127 7F

Extended ASCII CharactersDEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code

128 80 € Ç up arrow ↑ 0x48

129 81 ü down arrow ↓ 0x50

130 82 ‚ é right arrow → 0x4B

131 83 ƒ â left arrow ← 0x4D

132 84 „ ä Insert 0x52133 85 … à Delete 0x53134 86 † å Home 0x47135 87 ‡ ç End 0x4F136 88 ˆ ê Page Up 0x49137 89 ‰ ë Page Down 0x51138 8A Š è Right ALT 0x38139 8B ‹ ï Right CTRL 0x1D140 8C Œ î Reserved n/a141 8D ì Reserved n/a142 8E Ž Ä Numeric Keypad Enter 0x1C143 8F Å Numeric Keypad / 0x35144 90 É F1 0x3B145 91 ‘ æ F2 0x3C146 92 ’ Æ F3 0x3D147 93 “ ô F4 0x3E148 94 ” ö F5 0x3F149 95 • ò F6 0x40150 96 – û F7 0x41151 97 — ù F8 0x42152 98 ˜ ÿ F9 0x43153 99 ™ Ö F10 0x44154 9A š Ü F11 0x57155 9B › ¢ F12 0x58156 9C œ £ Numeric Keypad + 0x4E157 9D ¥ Numeric Keypad - 0x4A158 9E ž ₧ Numeric Keypad * 0x37159 9F Ÿ ƒ Caps Lock 0x3A160 A0 á Num Lock 0x45161 A1 ¡ í Left Alt 0x38

Printable Characters (Continued)DEC HEX Character DEC HEX Character DEC HEX Character

A - 4

Page 155: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

162 A2 ¢ ó Left Ctrl 0x1D163 A3 £ ú Left Shift 0x2A164 A4 ¤ ñ Right Shift 0x36165 A5 ¥ Ñ Print Screen n/a166 A6 ¦ ª Tab 0x0F167 A7 § º Shift Tab 0x8F168 A8 ¨ ¿ Enter 0x1C169 A9 © Esc 0x01170 AA ª ¬ Alt Make 0x36171 AB « ½ Alt Break 0xB6172 AC ¬ ¼ Control Make 0x1D173 AD ¡ Control Break 0x9D174 AE ® « Alt Sequence with 1 Character 0x36175 AF ¯ » Ctrl Sequence with 1 Character 0x1D176 B0 ° 177 B1 ± 178 B2 ² 179 B3 ³ 180 B4 ´ 181 B5 µ 182 B6 ¶ 183 B7 · 184 B8 ¸ 185 B9 ¹ 186 BA º 187 BB » 188 BC ¼ 189 BD ½ 190 BE ¾ 191 BF ¿ 192 C0 À 193 C1 Á 194 C2 Â 195 C3 Ã 196 C4 Ä 197 C5 Å í198 C6 Æ 199 C7 Ç 200 C8 È 201 C9 É 202 CA Ê 203 CB Ë 204 CC Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó 212 D4 Ô 213 D5 Õ

Extended ASCII Characters (Continued)DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code

A - 5

Page 156: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

214 D6 Ö 215 D7 × 216 D8 Ø 217 D9 Ù 218 DA Ú 219 DB Û 220 DC Ü 221 DD Ý 222 DE Þ 223 DF ß 224 E0 à α225 E1 á ß226 E2 â Γ227 E3 ã π228 E4 ä Σ229 E5 å σ230 E6 æ µ231 E7 ç τ232 E8 è Φ233 E9 é Θ234 EA ê Ω235 EB ë δ236 EC ì ∞237 ED í φ238 EE î ε239 EF ï ∩240 F0 ð ≡241 F1 ñ ±242 F2 ò ≥243 F3 ó ≤244 F4 ô ⌠245 F5 õ ⌡246 F6 ö ÷247 F7 ÷ ≈248 F8 ø °249 F9 ù ·250 FA ú ·251 FB û √252 FC ü ⁿ253 FD ý ²254 FE þ 255 FF ÿ

Extended ASCII Characters (Continued)DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code

A - 6

Page 157: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

ISO 2022/ISO 646 Character ReplacementsCode pages define the mapping of character codes to characters. If the data received does not display with the proper charac-ters, it may be because the bar code being scanned was created using a code page that is different from the one the host pro-gram is expecting. If this is the case, select the code page with which the bar codes were created. The data characters should then appear properly.

Code Page Selection Method/Country Standard Keyboard Country Honeywell Code Page Option

United States (standard ASCII)

ISO/IEC 646-IRV n/a 1

Automatic National Character Replacement

ISO/IEC 2022 n/a 2 (default)

Binary Code page n/a n/a 3

Default “Automatic National Character replacement” will select the below Honeywell Code Page options for Code128, Code 39 and Code 93.

United States ISO/IEC 646-06 0 1

Canada ISO /IEC 646-121 54 95

Canada ISO /IEC 646-122 18 96

Japan ISO/IEC 646-14 28 98

China ISO/IEC 646-57 92 99

Great Britain (UK) ISO /IEC 646-04 7 87

France ISO /IEC 646-69 3 83

Germany ISO/IEC646-21 4 84

Switzerland ISO /IEC 646-CH 6 86

Sweden / Finland (extended Annex C) ISO/IEC 646-11 2 82

Ireland ISO /IEC 646-207 73 97

Denmark ISO/IEC 646-08 8 88

Norway ISO/IEC 646-60 9 94

Italy ISO/IEC 646-15 5 85

Portugal ISO/IEC 646-16 13 92

Spain ISO/IEC 646-17 10 90

Spain ISO/IEC 646-85 51 91

A - 7

Page 158: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Dec 35 36 64 91 92 93 94 96 123 124 125 126

Hex 23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E

US 0 1 # $ @ [ \ ] ^ ` | ~

CA 54 95 # $ à â ç ê î ô é ù è û

CA 18 96 # $ à â ç ê É ô é ù è û

JP 28 98 # $ @ [ ¥ ] ^ ` | ⎯

CN 92 99 # ¥ @ [ \ ] ^ ` | ⎯

GB 7 87 £ $ @ [ \ ] ^ ` | ˜

FR 3 83 £ $ à ° ç § ^ µ é ù è ¨

DE 4 84 # $ § Ä Ö Ü ^ ` ä ö ü ß

CH 6 86 ù $ à é ç ê î ô ä ö ü û

SE/FI 2 82 # ¤ É Ä Ö Å Ü é ä ö å ü

DK 8 88 # $ @ Æ Ø Å ^ ` æ ø å ˜

NO 9 94 # $ @ Æ Ø Å ^ ` æ ø å ¨

IE 73 97 £ $ Ó É Í Ú Á ó é í ú á

IT 5 85 £ $ § ° ç é ^ ù à ò è ì

PT 13 92 # $ § Ã Ç Õ ^ ` ã ç õ °

ES 10 90 # $ § ¡ Ñ ¿ ^ ` ° ñ ç ˜

ES 51 91 # $ ∙ ¡ Ñ Ç ¿ ` ´ ñ ç ¨

CO

UN

TR

Y

Co

un

try

Key

bo

ard

Ho

ney

wel

l C

od

ePag

e ISO / IEC 646 National Character Replacements

A - 8

Page 159: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Unicode Key Maps

6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E

4B 50 554C 51 56

01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D1E

2C

1F 20 21 22 23 24 25 26 27 28 29 2B

392E 2F 30 31 32 33 34 35 36 37 534F 54 593A 3B 3C 3E 3F 38 403D

5A 5F 645B 60 655C 61 665D 62 6763 68

69

6A

6C

104 Key U.S. Style Keyboard

6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E

4B 50 554C 51 56

01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F10 11 12 13 14 15 16 17 18 19 1A 1B 1C1E

2C

1F 20 21 22 23 24 25 26 27 28 292B

392E 2F 30 31 32 33 34 35 36 37 534F 54 593A 3B 3C 3E 3F 38 403D

5A 5F 645B 60 655C 61 665D 62 6763 68

69

6A

6C

2A

2D

105 Key European Style Keyboard

A - 9

Page 160: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

A - 10

Page 161: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Sample SymbolsUPC-A

0 123456 7890

Interleaved 2 of 5

Code 128

EAN-13

Code 39

Codabar

1234567890

Code 128

9 780330 290951

BC321

A13579B

Code 93

123456-9$

Page 162: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Programming Chart

0

1

2

3

4

5

6

7

8

9

Page 163: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Programming Chart

Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.

A

B

C

D

E

F

Save

Discard

Reset

Page 164: Industrial Full Range Laser Scanner · Product Agency Compliance - Granit 1280i USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is

Honeywell Scanning & Mobility9680 Old Bailes RoadFort Mill, SC 29707

www.honeywellaidc.com

1280i-UG Rev A2/14