Indu-Sol GmbH Specialist in Fieldbus Technology 1 | PROFIBUS & PROFINET User Conference 2015 | presented: Indu-Sol GmbH | 16.07.2015 PROFINET The future of communication Marco Freihöfer

Transcript of Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 |...

Page 1: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

1 | PROFIBUS & PROFINET User Conference 2015 | presented: Indu-Sol GmbH | 16.07.2015

PROFINET

The future of communication

Marco Freihöfer

Page 2: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

2 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Common Points / Differences

1. Basics and quality parameters

1.1 Physical parameters

1.2 Logical parameters

2. Netload in PROFINET (Netload Class)

3. Metrological measurement and evaluation of quality parameters

PROFINET – The future of communication Abstract:

Page 3: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

3 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Common points with the classic fieldbus:

■ The physical basis, PROFIBUS / Interbus / CAN / SafetyBus p / AS-i

■ Balanced data transmission by means of differential voltage signal

■ Evaluation of communication quality over measuring/access points

Differences to classic fieldbus, e.g. PROFIBUS:

■ PROFIBUS has up to 32 devices in a segment, arranged linearly along a

passive line(max 125). PROFINET can be designed with up to 250 devices.

■ PROFIBUS logically functions according to the master/slave principle, using a

token passing procedure, only one telegram at a time – ‘male communication’

■ PROFINET uses the provider/consumer model, each device and the controller

send cyclic data without request at pre-set Update rate – ‘female communication’

■ PROFIBUS baudrate set once for all devices. In PN the updaterate for each

device can be set separately

■ Ethernet standard. Use of foreign protocols such as TCP/IP at the same line

(netload may spike).

Common points / differences

Page 4: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

■ Communication over 2 pair of wires (1-2 and 3-6)

■ Line-, star, ring topology

■ 2 devices are connected over 1 line

■ Integrated repeater function (switch function)

Controller Switch Switch Switch Switch

1 2 3 6

IP

Mac

Name

IP

Mac

Name

IP

Mac

Name

IP

Mac

Name

1. Basics and Quality Parameters

PROFINET – The future of communication

Page 5: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

5 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

1.1 Physical Parameters – CAT5 Certification

1. Basics and Quality Parameters

■ Line Length

■ Attenuation

■ Crosstalk

■ Specification after CAT5 Norm

■ 100 m max. Line length 24dB Attenuation

■ 1,5 m cable length also max 24dB Attenuation ???

PROFINET – The future of communication

Installed

cable length

Max. attenuation acc. to

standard Cat. 5e for 100

MHz

Length-dependent max.

attenuation, Indu-Sol

GmbH

Length-dependent

recommended

attenuation,

Indu-Sol GmbH

100 m 24 dB 24 dB 21 dB

50 m 24 dB 21 dB 18 dB

25 m 24 dB 18 dB 15 dB

12 m 24 dB 15 dB 12 dB

6 m 24 dB 12 dB 9 dB

3 m 24 dB 9 dB 6 dB

1.5 m 24 dB 6 dB 3 dB

Installed

cable length

Min. attenuation acc. to

standard Cat. 5e for 100

MHz

Length-dependent min.

attenuation Indu-Sol

GmbH

Length-dependent

min. attenuation Indu-

Sol GmbH

100 m 30 dB 30 dB 33 dB

50 m 30 dB 33 dB 36 dB

25 m 30 dB 36 dB 39 dB

12 m 30 dB 39 dB 42 dB

6 m 30 dB 42 dB 45 dB

3 m 30 dB 45 dB 48 dB

1.5 m 30 dB 48 dB 51 dB

Page 6: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

6 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

1.1 Physical Parameters - Linedepth

Every switch placed between a controller and a

Device leads to latency

During the design of a network, linedepth have to

be taken into account

1. Basics and Quality Parameters

PROFINET – The future of communication

I/O-Devices Terminal-Device I/O-Devices Terminal-Device

I/O-Devices

Terminal-Device

Page 7: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

7 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

1.1 Physical Parameters - Linedepth

Table for max linedepth at Store & Forward

Table for maximum linedepth at Cut Through

1. Basics and Quality Parameters

PROFINET – The future of communication

Max. linedepth at updaterate of

1 ms 2 ms 4 ms 8 ms

7 14 28 58

Max. linedepth at updaterate of

1 ms 2 ms 4 ms 8 ms

64 100 100 100

Page 8: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

8 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Caution: As it is unsure whether a device works in

Cut Through or Store & Forward modus, the design

of a network should be picked according to Store

& Forward (shorter line-depth) table.

PROFINET – The future of communication

1.1 Physical Parameters - Linedepth

Max. linedepth at updaterate of

1 ms 2 ms 4 ms 8 ms

7 14 28 58

1. Basics and Quality Parameters

Page 9: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

9 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

The Jitter describes the time variance of PROFINET

packets (delay)

Raising Jitter could be evidence for a exceeded linedepth,

changed netload or device failure

PROFINET – The future of communication

1.2 Logical Parameters - Telegramjitter

1. Basics and Quality Parameters

Page 10: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

10 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

4 ms

6 ms ∆ = 2ms = 50% Jitter

Examples of Error Patterns: Device falls of its own update rate To much TCP/IP traffic or disadvantageous topology Use of external, active diagnostic tools Recommendation Indu-Sol: 50%

PROFINET – The future of communication

1.2 Logical Parameters - Telegramjitter

1. Basics and Quality Parameters

Page 11: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

11 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

PROFINET – The future of communication

1.2 Logical Parameters - Telegramjitter

The real bus traffic “Jitter” (delay)

Update rate (arrival times)

1. Basics and Quality Parameters

Page 12: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

12 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

PROFINET – The future of communication

1.2 Logical Parameters - Telegramjitter

“Jitter” (delay)

Update rate (arrival times) Scheduled bus traffic

1. Basics and Quality Parameters

Page 13: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

13 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

PROFINET – The future of communication

1.2 Logical Parameters - Telegramjitter

1. Basics and Quality Parameters

Page 14: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

14 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

1.2 Logical Parameters – Telegram Gap

Missing telegram

Communication failures may happen within a network.

Failures need to be recognized fast enough to bring the

system in a defied safe state

PROFINET – The future of communication 1. Basics and Quality Parameters

Page 15: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

15 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

Caution: PROFINET per default accepts only 3 missing

telegrams in a row

Recommendation Indu-Sol: 0

PROFINET – The future of communication

1.2 Logical Parameters – Telegram Gap

1. Basics and Quality Parameters

Page 16: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

16 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

Telegram content defective

Communication failures may happen within a network.

Failures need to be recognized fast enough to bring the

system in a defied safe state

PROFINET – The future of communication

1.2 Logical Parameters – Error Telegram

1. Basics and Quality Parameters

Page 17: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

17 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

1.2 Logical Parameters – Error Telegram

Caution: PROFINET per default accepts only 3 missing

telegrams in a row

Recommendation Indu-Sol: 0

PROFINET – The future of communication 1. Basics and Quality Parameters

Page 18: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

18 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

The netload of a network should be measured during full

operation

Communication lines with additional TCP/IP traffic

become more relevant

PROFINET – The future of communication

1.2 Logical Parameters – Loading Ratio

1. Basics and Quality Parameters

Page 19: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

19 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

1. Basics and Quality Parameters

Caution: to much TCP/IP traffic can lead into

communication failure

Recommendation Indu-Sol: 100:1

PROFINET – The future of communication

1.2 Logical Parameters – Loading Ratio

Page 20: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

20 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

Controller Switch

IP

PROFINET – The future of communication 1. Basics and Quality Parameters

1.2 Logical Parameters – Netload

Page 21: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

21 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

In order to leave enough reserve for network expansion and

or additional NRT traffic (TCP/IP) netload should not be

exceeded.

PROFINET – The future of communication

1.2 Logical Parameters – Netload

1. Basics and Quality Parameters

Netload Recommendation

<20%: no action necessary

20…50%: Check-up of planned netload is recommended

>50%: measures to decrease netload are demanded

Page 22: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

22 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Controller Switch

IP

Throughput per time unit (max. 100 MBit/s – Line

capacity)

Devices are specified after there throughput capacity

Recommendation Indu-Sol: 20%

PROFINET – The future of communication 1. Basics and Quality Parameters

1.2 Logical Parameters – Netload

Page 23: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

23 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Netload

Jitter

Telegram Gaps

Loding Ratio

Error Telegrams

< 50%

0

0

< 20%

100:1

Recommendations

1.2 Logical Parameters - Overview

PROFINET – The future of communication 1. Basics and Quality Parameters

Indu-Sol

Page 24: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

24 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

Normal Operation Limited Operation Faulty Operation

Cyclic and acyclic

communication

Only cyclic communication No communication

function

Netload-Class 1 < 1% < 5% > 5%

Netload-Class 2 - - -

Netload-Class 3 < 5% < 30% > 30%

■ Normal Operation

cyclic und acyclic data is being processed without restrictions

■ Limited Operation

cyclic data is being processed, acyclic data may be discarded

■ Faulty Operation

device can shut down

■ Once the netload returned to normal the device must power up again automatically

PROFINET – The future of communication 2. Netload in PROFINET (Netload Classes)

Page 25: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

25 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

2. Netload in PROFINET (Netload Classes)

Netload is to measure at nodes with concentrated

communication (Controller)

Multi controller networks need to be measured at each

controller separately

PROFINET – The future of communication

Page 26: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

26 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

IP IP IP IP

Controller

Switch Switch Switch Switch

■ Evaluation of Communication quality with PROFINET-INspektor®

■ Performance measure with a PASSIVE and direct network access point

3. Metrological measurement and evaluation of Quality Parameters

PROFINET – The future of communication

Page 27: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

27 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

■ Device matrix with status bar

Telegramjitter

Telegram Gap

Error Telegram

Loading Ratio

Netload

PROFINET – The future of communication 3. Metrological measurement and evaluation of Quality Parameters

Page 28: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

28 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

PROFINET – The future of communication 3. Metrological measurement and evaluation of Quality Parameters

Page 29: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

29 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

PROFINET – The future of communication 3. Metrological measurement and evaluation of Quality Parameters

Page 30: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

30 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

PROFINET – The future of communication 3. Metrological measurement and evaluation of Quality Parameters

Page 31: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

32 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

■ Gather information about Topology, Device setup or

Linedepth with PROscan® Active

PROFINET – The future of communication 3. Metrological measurement and evaluation of Quality Parameters

Page 32: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

33 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

■ Documentation and Device List

PROFINET – The future of communication 3. Metrological measurement and evaluation of Quality Parameters

Page 33: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

34 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015

■ Portstatistics

■ Errorcounter

■ Powerbudget

■ Connection Type

■ Discards

PROFINET – The future of communication 3. Metrological measurement and evaluation of Quality Parameters

Page 34: Indu-Sol GmbH Specialist in Fieldbus Technology … GmbH – Specialist in Fieldbus Technology 4 | PROFIBUS & PROFINET User Conference 2015| presented: Indu-Sol GmbH | 16.07.2015 Communication

Indu-Sol GmbH – Specialist in Fieldbus Technology

35 | PROFIBUS & PROFINET User Conference 2015 | presented: Indu-Sol GmbH | 16.07.2015

Do you have Questions?