Indoor Air Study Data Summary and Analysis Report Main TCE Plume, OU5 Former Lowry Air Force Base Denver, Colorado Prepared by: EnviroGroup Limited Centennial, Colorado Prepared for: Lowry Assumption, LLC Denver, Colorado December, 2010 Project No. LO-0671

Transcript of Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to...

Page 1: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report

Main TCE Plume, OU5 Former Lowry Air Force Base

Denver, Colorado

Prepared by:

EnviroGroup Limited Centennial, Colorado

Prepared for:

Lowry Assumption, LLC Denver, Colorado

December, 2010

Project No. LO-0671

Page 2: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited i

TABLE OF CONTENTS EXECUTIVE SUMMARY

1  INTRODUCTION...................................................................................................... 1 

1.1  Scope of Work.............................................................................................. 1 

1.2  Report Organization ..................................................................................... 2 

2  BACKGROUND INFORMATION ............................................................................ 3 

2.1  Historic Investigation Observations .............................................................. 3 

2.2  Operable Unit 5 Groundwater Status ........................................................... 5 

2.3  Compounds of Concern ............................................................................... 6 

2.4  Background Considerations ......................................................................... 7 

3  INVESTIGATION PROCEDURES........................................................................... 8 

3.1  Residential Sampling Locations ................................................................... 8 3.1.1  Contacting Candidate Residences.............................................................8 3.1.2  Candidate Interview Documentation ........................................................9 

3.2  Indoor and Outdoor Air Sampling Procedures ............................................. 9 

3.3  Sub-slab Vapor Sampling Procedures ....................................................... 10 

3.4  Soil Vapor Probe Installation and Sampling Procedures............................ 11 

3.5  Groundwater Sample Collection................................................................. 13 

4  LABORATORY PROCEDURES ........................................................................... 14 

4.1  Indoor Air, Outdoor Air, Sub-Slab Vapor, and Soil Vapor Samples ........... 14 

4.2  Groundwater Samples................................................................................ 16 

5  QUALITY ASSURANCE/QUALITY CONTROL .................................................... 17 

5.1  Laboratory QA/QC Requirements .............................................................. 17 

5.2  Field QA/QC Requirements........................................................................ 17 5.2.1  Trip Blanks .............................................................................................17 5.2.2  Field Duplicates ......................................................................................18 5.2.3  Ambient Air ............................................................................................18 5.2.4  Canister Vacuums ...................................................................................19 

Page 3: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited ii

5.3  Data Validation ........................................................................................... 19 

6  INVESTIGATION RESULTS ................................................................................. 20 

6.1  Indoor Air Investigation............................................................................... 20 6.1.1  Indoor Air Analytical Results .................................................................20 6.1.2  Outdoor Air Analytical Results ..............................................................21 6.1.3  Sub-Slab Vapor Analytical Results ........................................................21 

6.2  Soil Vapor Investigation.............................................................................. 22 

6.3  Groundwater Investigation ......................................................................... 22 

7  GROUNDWATER TO INDOOR AIR PATHWAY EVALUATION.......................... 23 

7.1  Indoor Air vs Screening Levels................................................................... 23 

7.2  Indoor vs Background Concentrations ....................................................... 23 7.2.1  Indoor Air to Outdoor Air Concentration Comparison...........................24 7.2.2  Indoor Air to Background Indoor Air Comparison ................................24 

7.3  Indoor Air vs Subsurface Concentrations................................................... 25 7.3.1  Comparison of Indoor Air to Sub-slab Vapor Concentrations ...............25 7.3.2  Comparison of Indoor Air to Soil Vapor Concentrations .......................26 7.3.3  Comparison of Sub-slab Vapor to Soil Vapor Concentrations ...............26 7.3.4  Comparison of Indoor Air to Groundwater Concentrations ...................27 

7.4  Attenuation Factors .................................................................................... 27 7.4.1  Attenuation from Sub-slab Vapor to Indoor Air.....................................28 7.4.2  Attenuation from Soil Vapor to Indoor Air ............................................28 7.4.3  Attenuation from Groundwater to Soil Vapor ........................................29 7.4.4  Attenuation from Groundwater to Indoor Air.........................................29 

7.5  Trend Analysis............................................................................................ 29 7.5.1  Groundwater Concentration Trends over Time ......................................30 7.5.2  Soil Vapor Concentration Trends over Time..........................................30 7.5.3  Sub-slab Vapor Concentration Trends over Time ..................................30 7.5.4  Indoor Air Concentration Trends over Time ..........................................31 7.5.5  Comparison of Indoor Air to Sub-slab Vapor.........................................32 7.5.6  Comparison of Indoor Air to Soil Vapor ................................................32 7.5.7  Comparison of Soil Vapor to Groundwater ............................................32 7.5.8  Comparison of Indoor Air to Groundwater ............................................32 

8  CONCLUSIONS..................................................................................................... 34 

9  REFERENCES....................................................................................................... 35 

Page 4: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited iii

LIST OF TABLES

Table 1 Chronology of Investigation and Remediation Activities

Table 2 Compounds of Concern and Common Abbreviations

Table 3 Reporting Limits for Air and Vapor Samples

Table 4 Reporting Limits for Groundwater Samples

Table 5 Indoor and Outdoor Air Analytical Results

Table 6 Sub-slab Vapor Analytical Results

Table 7 Soil Gas Analytical Results

Table 8 Groundwater Analytical Results

Table 9 Sub-slab Vapor to Indoor Air Attenuation Factors

Table 10 Soil Gas to Indoor Air Attenuation Factors

Table 11 Groundwater to Soil Gas Attenuation Factors

Table 12 Groundwater to Indoor Air Attenuation Factors

Table 13 Historical Groundwater Analytical Results and Percent TCE Reductions

Table 14 Historical Soil Gas Analytical Results and Percent TCE Reductions

Table 15 Historical Sub-slab Vapor Analytical Results and Percent TCE Reductions

Table 16 Historical Indoor Air Analytical Results and Percent TCE Reductions

LIST OF FIGURES

Figure 1 Site Map with Current and Historical Sample Locations

Figure 2 Maximum TCE Concentrations in Indoor Air, January 2010

Figure 3 TCE Concentrations in Sub-slab Vapor, January 2010

Figure 4 TCE Concentrations in Soil Gas, January 2010

Figure 5 TCE Concentrations in Groundwater, January 2010

Figure 6 TCE Concentrations in Groundwater vs. Time, 1996 to 2010

Figure 7 TCE Concentrations in Soil Gas vs. Time, 1998 to 2010

Figure 8 TCE Concentrations in Sub-slab Vapor vs. Time, 1998 to 2010

Page 5: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited iv

Figure 9 Average Percent Reduction in TCE Concentrations by Media, 1996 to 2010

Figure 10 TCE Concentrations in Groundwater and Indoor Air vs. Time, 2001 to 2010

LIST OF APPENDICES (ON DISC)

Appendix A Homeowner Questionnaires and Inspection Forms, Floor Plan Sketches, and Chemical Inventories

Appendix B Soil Vapor Sample Collection Log

Appendix C Sub-slab Vapor Sample Collection Log

Appendix D 2010 Soil Vapor Laboratory Reports (on CD)

Appendix E 2010 Sub-slab Vapor and Indoor Air Laboratory Reports (on CD)

Page 6: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited v

EXECUTIVE SUMMARY

Lowry Assumption, LLC (LAC) has been aggressively treating groundwater in the Northern Off-site Plume as part of the remediation of base-wide groundwater (Operable Unit 5 [OU5]) at the former Lowry Air Force Base (Lowry). This treatment has resulted in significant reductions of trichloroethylene (TCE) concentrations in groundwater plume-wide. As documented in the Phase 2 Corrective Action Plan for Groundwater Cleanup at Lowry (LAC 2006), this aggressive treatment was determined to be the best approach to protect human health and the environment and to mitigate any potential exposures to the public. Because the groundwater-to-indoor air pathway is the only potentially complete exposure pathway at the site, several studies, beginning in 1997, were performed to assess the impact of groundwater-derived TCE on indoor air and to evaluate the success of mitigation efforts under the Corrective Action Plan. The objectives of this study, which updates the evaluation of the mitigation efforts, are:

• to characterize the groundwater to indoor air pathway through sampling, and

• to evaluate whether observed decreases in groundwater VOC concentrations over time have resulted in similar decreases in VOC concentrations in indoor air, sub-slab, and soil vapor.

This report presents the results of the January 2010 sampling program and compares those results with historical data to evaluate trends and draw conclusions regarding the progress of remedial efforts, and the efficacy of using groundwater concentrations to assure protectiveness of the remedy. The data show strong correlations between the alluvial groundwater and indoor air TCE concentrations, (as well as soil gas and subslab concentrations) indicating that as groundwater concentrations decrease, there are comparable decreases in indoor air concentrations; thus the current remedy is shown to be effectively mitigating risks through the indoor air pathway. Remediation of the groundwater in the study area, in addition to natural attenuation of the contaminant, has resulted in decreases in average groundwater TCE concentration of approximately 90 percent (currently approximately 11 micrograms/liter [μg/L], reduced from 110 in 1998-99) with an average concomitant decrease in indoor air concentrations of approximately 75%. Colorado Department of Public Health and Environment (CDPHE) has established risk management levels for TCE in indoor air in its Proposed Policy On Interim Risk Evaluation And Management Approach For TCE (2004), and these levels are used throughout this report as a point of reference. Seven of the nine homes tested have concentrations that are below mitigation action levels defined in the policy (0.8 micrograms per meters squared [μg/m3] - lowest action level at which mitigation may be recommended), and a decrease of as little as one ug/L in the groundwater TCE concentration is predicted to reduce annual average values in the remaining two homes to concentrations below CDPHE action levels

Page 7: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 1

1 INTRODUCTION

This Indoor Air Study Data Summary and Analysis Report was prepared in accordance with Consent Agreement No. 01-08-07-02 among Lowry Redevelopment Authority, Lowry Assumption, LLC (LAC) and the Colorado Department of Public Health and Environment (CDPHE). It is based on work performed by EnviroGroup Limited (EnviroGroup) and LAC in January and February 2010 and a review of analytical data from previous investigations.

LAC is currently remediating groundwater under an approved Corrective Action Plan (CAP) for base-wide groundwater (Operable Unit 5 [OU5]) at the former Lowry Air Force Base (Lowry). As approved in the CAP, the aggressive groundwater treatment being implemented was determined to be the best approach to protect human health and the environment and to mitigate any potential exposures to the public. As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater was implemented in January 2010. The program, a follow-up to three previous investigations related to indoor air, was designed to assess whether or not observed decreases in dissolved volatile organic compound (VOC) concentrations in groundwater have resulted in comparable decreases in VOC concentrations in indoor air, sub-slab vapor, and soil vapor concentrations. The study area that was the focus of this investigation overlays the Main Trichloroethene (TCE) Plume and is bounded by 12th and 14th Avenues on the south and the north, and by Ulster and Valentia Streets on the west and east (Study Area), as shown on Figure 1.

1.1 SCOPE OF WORK

The scope of work was presented in EnviroGroup’s Indoor Air Study Work Plan (Work Plan), dated December 9, 2009 (EnviroGroup, 2009), which was reviewed and approved by CDPHE on January 4, 2010. The approved Work Plan described the procedures for conducting an indoor air study north of Lowry to repeat and update the 2007 indoor air study completed by LAC. The program included sampling of up to 14 residences (including indoor air and sub-slab vapor) and the collection of up to15 soil vapor samples from existing permanent soil vapor probes in the Study Area.

The timing of the Indoor Air Study coincided with the January 2010 OU5 Main TCE Plume closure/performance groundwater monitoring program (GMP) sampling. The groundwater data collected during the GMP have been used for the characterization of the groundwater-to-indoor air pathway presented in this report.

Page 8: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 2

All investigation activities were conducted in accordance with the Work Plan to characterize indoor air quality conditions in the residences above the Main TCE Plume and were designed to support the ultimate closure of OU5.

1.2 REPORT ORGANIZATION

The following sections of the report present background information (Section 2.0); investigation procedures (Section 3.0); laboratory procedures (Section 4.0); quality assurance/quality control (Section 5.0); investigation results (Section 6.0); and evaluation of the groundwater to indoor air pathway (Section 7.0); conclusions (Section 8.0); and references (Section 9.0).

Page 9: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 3

2 BACKGROUND INFORMATION

This section summarizes historical investigation observations, groundwater data, identifies the compounds of concern, and discusses background concentration considerations.

2.1 HISTORICAL INVESTIGATION OBSERVATIONS

The environmental program at Lowry began in 1983 with the Air Force Installation Restoration Program. Contamination in the groundwater, primarily from TCE, was identified in three distinct plumes (i.e., Main TCE, Headquarters Area, and Fire Training Zone). The largest of the plumes, the Main TCE Plume, extended approximately three miles (at that time) to the north from source areas within the former base and passes under the study area, a residential area north of the base. The Headquarters Area and Fire Training Zone plumes are limited in areal extent and do not underlie any residential properties. Compared with average monitoring data from 1998-1999, average TCE concentrations in groundwater within the study area at the time of the 2010 indoor air study have dropped 90% (LAC, 2010b). This decrease resulted from the combination of interim remedial actions, active remediation, and natural degradation processes. Ongoing active remediation prior to this study included three full scale potassium permanganate injections that were performed in the study area in 2004, 2007, and 2009. Based on January 2010 groundwater data (LAC, 2010a) from samples collected in the study area, there have been additional reductions in the average TCE concentration of 56% within the study area since the previous indoor air study was performed in 2007.

The groundwater-to-indoor air migration pathway was studied as part of the OU5 investigation because of the potential risks from volatilization of VOCs dissolved in groundwater and the potential migration of these VOCs into overlying structures. During three previous investigations conducted in 1997-98, 2001, and 2007, the groundwater-to-shallow soil vapor pathway was investigated using a combination of groundwater, indoor air, outdoor air, sub-slab vapor, and soil vapor samples (Versar 2001, 2003 and LAC 2008). This 2010 study focused on the same sample locations in an effort to quantify the changes in indoor air, sub-slab vapor, and soil vapor TCE concentrations, as the concentrations in groundwater have decreased over time.

Following an initial indoor air sampling program conducted in September 1997 at the Heritage Estates apartments, located over the Main TCE Plume and immediately north of 11th Avenue, the Air Force installed active sub-slab depressurization (ASD) systems in all buildings at the complex that overlie the Main TCE Plume (Versar, 1999). In December 1997, the Air Force began an investigation to delineate areas where the groundwater-to-indoor air pathway was potentially complete (Versar, 2001 – Appendix

Page 10: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 4

K). Eight of the 16 homes sampled in 1998 in the Versar 2001 study were tested again in one of the later studies, and six of these were sampled in the present study. The Phase III groundwater-to-indoor air study (Versar, 2003) focused on residences overlying the center of the Main TCE Plume between 12th and 13th Street, an area which was understood to represent the worst-case scenario for transport of VOCs from groundwater-to-indoor air due to the relatively high groundwater concentrations. In that study, indoor air samples were collected in 13 residences at two month intervals over a period of one year between March 2000 and February 2001(the present study includes new sample data from four of the homes from the 2000-2001 study). Additionally, sub-slab vapor or crawlspace air, outdoor air, and groundwater samples were collected. The data were used to assess health risks, regardless of confounding influences from indoor or outdoor sources or background. The groundwater exposure point concentration of 1.4x10-5 exceeded the target risk level at that time of 1x10-5 in one residence (1235 Uinta). The Air Force installed an ASD system in that residence and it began operation in March 2003, although the system was temporarily turned off during the 2007 sampling event. These data also demonstrated that indoor air concentrations were highest in the winter samples with concentrations twice the annual average (Versar, 2003, Table 5-1).

Active remediation of the OU5 groundwater plumes with a chemical oxidant (e.g., potassium permanganate) began in 2004 following treatability studies and the development of the Phase II Corrective Action Plan (Phase II CAP) (LAC, 2006). TCE was identified as the primary contaminant in the Lowry plumes; however, a full suite of VOCs are evaluated in the groundwater monitoring programs. Throughout the Main TCE Plume, there have been four rounds of chemical oxidant treatment that have been completed on-base and three rounds completed off-base since the fall of 2004, and additional treatment is currently ongoing. For the entire period of investigation and treatment of the Main TCE Plume, which began as early as 1983, there has been an average decrease in TCE concentrations in groundwater of approximately 83 to 95% for wells completed in the alluvium (LAC 2010, pending RPASS). These percentages are based on using the initial versus the latest measured concentrations (as of January 2010) and the minimum versus maximum concentrations detected in the wells, respectively.

A follow-up indoor air study was implemented by LAC in 2007. The program was designed to assess whether or not observed decreases in dissolved VOC concentrations in groundwater have resulted in comparable decreases in VOC concentrations in soil vapor, sub-slab vapor, and indoor air. Fourteen residences between 12th and 13th Street were targeted for indoor air and sub-slab sampling, nine of which granted access. In that study a reduction in average groundwater concentrations of approximately 44% was observed, associated with reductions in the average concentrations of soil vapor (30%), sub-slab air (53%), and indoor air (58%) when comparing the 2007 data to the earlier studies performed in 1998 and 2001. Further reductions in groundwater concentrations were observed in the study area following

Page 11: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 5

groundwater treatment in the fall of 2007, and projections of indoor air reductions were made based on the ratios calculated in the 2007 study.

2.2 OPERABLE UNIT 5 GROUNDWATER STATUS

A large amount of groundwater data have been collected in and around the Main TCE Plume under various investigation, remediation, and monitoring programs. Since the remediation of OU5 was privatized, LAC has collected groundwater data semi-annually from June 2003 through January 2010. Through December 2006, a semi-annual groundwater monitoring network of up to 70 wells was used for long-term monitoring and remediation performance monitoring of the three TCE groundwater plumes (LAC, 2004). In 2007, the semi-annual monitoring network was revised for the Main TCE Plume to create a Closure/Performance GMP network (LAC, 2007b) in order to support the eventual regulatory closure of the Main TCE Plume.

Monitoring wells within the study area used during this program are shown on Figure 1. All of these wells have been sampled at some point during previous monitoring programs and have been analyzed for VOCs by EPA Method 8260, and data from these wells were used to develop the target analyte list used for the indoor air studies.

Alluvial groundwater concentrations of TCE in the Study Area have declined since the earliest samples were collected in approximately 1996 and additional information is available in the OU5 Remedial Investigation (Versar, 2001) and the semi-annual GMP reports. In the initial groundwater-to-indoor air pathway evaluation (Appendix K; Versar, 2001) the average alluvial TCE concentration based on data reported for 1996-1998 in the Study Area and the area immediately south (Heritage Estates) was 110 micrograms per liter (μg/L). The average concentration in the 2007 study was 25 μg/L, and the current average concentration (January 2010) is 11 ug/L.

A summary of historical Investigation and Remediation activities is presented in Table 1.

Page 12: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 6

Table 1. Chronology of Investigation and Remediation Activities

Date Activity

June – November 1997

Initial pathway evaluation sampling (groundwater, soil gas, indoor air) of Heritage Estates and on-base buildings

December 1997 – January 1998

Installation of active sub-slab depressurization system at Heritage Estates

1998 OU5 RI groundwater-to-indoor air pathway evaluation

2000-2002 Phase 3 groundwater-to-indoor air contaminant migration pathway investigation

January 2003 Transition plan for groundwater cleanup and landfill closure at Lowry March 2003 Installation of active sub-slab depressurization at residence UA03

2003 Phase 1 Corrective Action Plan (CAP) for groundwater remediation 2003 Treatability studies and Phase 2 CAP

Fall 2004 First round of potassium permanganate injections (on- and off-base) Fall 2006 Second round of potassium permanganate injections (on-base)

March 2007 First LAC indoor air study Fall 2007 Second round of potassium permanganate injections (off-base)

Spring 2008 Third round of potassium permanganate injections (on-base) Summer/Fall 2009 Fourth and Third round of potassium permanganate injections (on-

and off-base) January - April 2010 Second LAC indoor air study and final site report

2.3 COMPOUNDS OF CONCERN

Ten compounds of concern (COCs) were selected as the target analytes for this investigation based on previous indoor air studies, as summarized in Table 2 below. These analytes include VOCs historically detected in groundwater samples in OU5 and potential degradation products of those compounds (Versar, 2003).

Page 13: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 7

Table 2. Compounds of Concern and Common Abbreviations

Vinyl Chloride 1,1-Dichloroethene (1,1-DCE)

Trichloroethene (TCE) Tetrachloroethene (PCE)

cis-1,2-Dichloroethene (cis-1,2-DCE) trans-1,2-Dichloroethene (trans-1,2-DCE)

1,1-Dichloroethane (1,1-DCA) 1,2-Dichloroethane (1,2-DCA)

1,1,1-Trichloroethane (1,1,1-TCA) 1,1,2-Trichloroethane (1,1,2-TCA)

2.4 BACKGROUND CONSIDERATIONS

Investigations at other sites in the Denver Metropolitan Area and pertinent literature have demonstrated that some or all of the COCs present in the affected groundwater are routinely found in indoor air that is unaffected by VOCs in groundwater (Kurtz & Folkes, 2002; Foster, et.al., 2002; Kurtz et.al. 2010). Many of these constituents are also found in outdoor air. Potential sources of these constituents include, but are not limited to: consumer products, dry cleaned clothes, building materials, and industrial, commercial and residential uses of chemicals or products that result in releases of VOCs to the indoor and ambient air. For the purpose of this investigation, VOCs present from these non-groundwater sources are considered “background”.

The investigation procedures used during implementation of the Work Plan were designed to identify impacts from background concentrations of the constituents in indoor air. Residents were interviewed regarding product use in their home and requested to limit uses of VOC-containing substances during the sampling period. Concentrations of VOCs in outdoor air were measured concurrently with indoor air measurements to identify baseline conditions. COCs detected in indoor air, but not detected in sub-slab vapor and soil vapor, may also be used to define background contributions. EnviroGroup has used a line-of-evidence approach to evaluate background contributions to indoor air results.

Page 14: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 8

3 INVESTIGATION PROCEDURES

This section presents procedures for contacting and interviewing candidate residences, sampling procedures and collection methods for indoor air, sub-slab vapor, soil vapor, outdoor air, and groundwater samples. All work was performed in accordance with the project Quality Assurance/Quality Control (QA/QC) Plan and Health and Safety Plan (HASP).

3.1 RESIDENTIAL SAMPLING LOCATIONS

The residential sampling program was based upon the attempted sampling of 14 previously sampled buildings in the Study Area to assess changes in VOC concentrations in indoor air and sub-slab vapor (Versar, 2001 and 2003; LAC, 2008). During the previous studies, indoor air and sub-slab vapor samples were collected in a total of 14 residences overlying the Main TCE Plume with full or partial basements. During the March 2007 study, attempts were made to resample all 14 homes; however, permission to sample was received for only nine of these residences (LAC, 2008). During the January 2010 study, although attempts were again made to sample all 14 homes, permission to sample was received from only nine of these residences, six of which had been sampled in 2007. The two homes at 1264 and 1268 Uinta did not permit sampling during either the 2007 study or the present study. These two homes are omitted from tabulations and further discussion so that only 12 homes appear in the historical indoor air comparison table.

Two indoor air samples and one sub-slab vapor sample were collected from each of the nine previously sampled buildings. Indoor air samples were collected from the basement and first floor. Crawl space samples were collected from three of the homes. For quality control/quality assurance (QA/QC) purposes, a contemporaneous outdoor air sample was intended to be collected during each day of indoor air and sub-slab vapor sample collection. Samples were not collected during two days of indoor air sampling due to an insufficient number of sample canisters. The five outdoor air samples collected are considered to be adequately representative for the two locations sampled on these dates.

3.1.1 Contacting Candidate Residences

Property owner contact information for the 14 candidate residences was obtained from the Denver County Assessor’s office. A letter, reviewed and approved by LAC, requesting participation in the indoor air study was sent to each property owner with a postage paid post card. If the owner did not respond, a second letter was hand delivered. For any owners that did not respond, attempts were made to speak with the owner personally or by phone. As during the March 2007 study, permission was obtained to collect

Page 15: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 9

indoor air and sub-slab vapor samples at nine of the 14 candidate residences (but not at all of the same residences). The owners of three homes (1264 Uinta, 1268 Uinta, and 1329 Uinta) denied access while no response was received from the owners of the remaining two homes (1271 Uinta and 1314 Ulster).

3.1.2 Candidate Interview Documentation

Prior to sampling activities, a resident at each sampling location was interviewed by EnviroGroup personnel. An approved questionnaire was administered during sampling activities. A home inspection and floor plan sketch to establish construction details relevant to vapor intrusion evaluation (such as locations of dry wells, sumps, foundation cracks, type of heating and ventilation system, sources of outdoor air, etc.) and a chemical inventory were completed to identify obvious sources or activities that could produce COCs and potentially affect indoor air samples.

During sampling activities, each residence was inspected for an existing radon mitigation system and the status of that system, if applicable. The radon mitigation system at 1235 Uinta was turned off approximately one week prior to indoor air sampling. The completed questionnaire, floor plan sketch, and chemical inventory for each residence are provided in Appendix A.

3.2 INDOOR AND OUTDOOR AIR SAMPLING PROCEDURES

A minimum of two indoor air samples and one sub-slab vapor sample were collected from nine of the 14 candidate residences. A total of nine indoor air samples from the 1st floor, 11 indoor air samples from basements, and three indoor air samples from crawl spaces were collected from nine residences. These numbers also include samples collected during resampling of the basement at 1282 Uinta Street. This home was resampled because the initial sub-slab sample result yielded all non-detectable concentrations and was thus considered suspect. Resampling required paired sub-slab and indoor air measurements.

Indoor air sample locations were selected away from vents, windows, and chemical sources, in a centrally-located area, at a height of approximately three feet above the floor to represent the breathing zone. Residents were asked to keep windows and doors closed during the entire sampling period. In addition, one outdoor air sample was collected for each day of indoor air sampling, contemporaneous with indoor air sampling, for comparison to the indoor air results. Due to a shortage of sampling containers, no outdoor air samples were collected on January 27 or February 23 in conjunction with the indoor air sampling at 1350 Ulster and resampling at 1282 Uinta, respectively. The outdoor air samples were collected immediately outside the buildings (i.e., not closer than 5 feet), on the upwind side, away from any exhaust from the buildings (e.g., exhaust vents) or wind obstructions, at a height of

Page 16: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 10

approximately three feet above ground level, and distant from any obvious source of VOCs at the residences. A total of five outdoor air samples were collected.

Indoor and outdoor air samples were collected over a 24 hour time period utilizing dedicated, laboratory-set regulators and 6 Liter (L) Summa® (or equivalent) canisters supplied and individually certified clean to reporting limit levels by Air Toxics Ltd., of Folsom, California (Air Toxics). Each canister had an initial field vacuum reading of at least 24 inches of mercury (Hg) prior to sampling and had a final field vacuum reading of 3 inches Hg or greater upon the completion of sample collection, with three exceptions. The final canister vacuum in sample LAI02 was equal to -0.18 inches Hg, the final canister vacuum in sample LAI23 was equal to -0.91 inches Hg, and the final canister vacuum in sample LAI09 was equal to 0 inches Hg. For the latter sample, the sampling duration may have been less than 24 hours.

Samples were shipped to the laboratory within three days of sampling so that no sample exceeded the 30-day holding time for the TO-15 method. Full chain of custody documentation was maintained for all canisters from time of shipping from the laboratory to the time of analysis. Historical and current indoor air sample locations are shown on Figure 1.

3.3 SUB-SLAB VAPOR SAMPLING PROCEDURES

After the indoor air samples were collected, one sub-slab vapor sample was collected from each of the nine residences. One additional sample was collected during resampling of the sub-slab vapor at 1282 Uinta Street. Sub-slab vapor samples were collected near the same locations where the previous samples were collected when possible (previous locations were found in approximately half of the sampled homes).

When possible, and as permitted by the owners, the sub-slab vapor samples in residences were collected in a central location, away from foundation footings and obvious slab perforations, on the lowest floor of the residence. Temporary probes were installed by drilling approximately 1/2 or 3/4 inch outer diameter (OD) holes through the basement or first floor slabs, as applicable, and no further than 2 inches into the underlying sub-slab materials. The 1/2 or 3/4 inch OD hole was then over-drilled with a larger 1.5 inch OD hole to a depth of about 1 inch below the slab surface. A new, clean length of 0.190 inch inner diameter (ID) x 0.25 inch OD Nylaflow® tubing, fitted with an acrylic screen, was inserted into the hole to the base of slab and sealed in the hole with hydrated bentonite.

Sub-slab vapor samples were collected using current state of the art procedures. During sub-slab vapor sampling activities, a clean, small plastic or stainless steel shroud with two small ports was placed over each sub-slab vapor probe and weighted down. An air-tight seal of foam was placed on the ground

Page 17: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 11

surface around the edge of the shroud where it contacted the ground. The sub-slab vapor probe tube, which was fitted with an air-tight valve, was then extended up through the air-tight seal of foam to the exterior side of the shroud.

Each sub-slab vapor tube, connected to an air-tight valve, was then connected with a tedlar bag attached to one side of the valve and the sampling tube on the other side of the valve (both outside of the shroud). Prior to purging or sampling activities, helium tracer gas was released via a small diameter tube through a port in the shroud into the enclosure beneath the shroud. A sample of the air inside the shroud was measured through the second port using a portable helium detector to determine the concentration of helium within the enclosure beneath the shroud.

As historically done, sub-slab vapor probes were purged (i.e., up to 0.5 L) at a flow rate of 100 to 200 milliliters (mL) per minute, through the shroud into a 60 mL calibrated gas-tight syringe and transferred to the tedlar bag. The tedlar bag was then connected to a portable helium detector to measure for the presence of helium gas in the purged vapor. If high concentrations (>10% of the shroud concentration) of helium were observed in the purge vapor, the sub-slab probe seal was checked and/or enhanced to reduce the infiltration of ambient air into the enclosure and another sample collected. If helium concentrations were less than 10%, a sub-slab vapor sample was collected for analysis. Upon completion of sampling activities, all sub-slab vapor probes were removed and holes filled with bentonite and sealed with concrete.

Sub-slab vapor samples were collected over approximately a 10 minute time period utilizing dedicated, laboratory-set regulators and 1 L Summa® (or equivalent) canisters supplied and individually certified clean to reporting limit levels by Air Toxics. Each canister had an initial field vacuum reading of at least 24 inches Hg prior to sampling and had a final field vacuum reading of 4 inches Hg or greater upon the completion of sample collection.

Samples were shipped to the laboratory within three days of sampling so that no sample exceeded the 30-day holding time for the TO-15 method. Full chain of custody documentation was maintained for all canisters from time of shipping from the laboratory to the time of analysis. Historical and current sub-slab vapor sample locations are shown on Figure 1. Sub-slab vapor collection information is summarized on the Sub-slab Vapor Sample Collection Logs provided in Appendix B.

3.4 SOIL VAPOR PROBE INSTALLATION AND SAMPLING PROCEDURES

In cases where a damaged or missing soil vapor point was indentified, a replacement soil vapor point was installed by LAC prior to the indoor air study as follows. Using direct push methods, a continuous core

Page 18: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 12

was collected to a depth of ten feet below ground surface to identify a permeable zone for sampling at a depth representative of the bottom of a basement slab. After the soil vapor sampling location was cored, a small OD sampling tube (i.e., 1/4 inch) with a vapor sampling probe tip was installed at each location to a depth of seven to ten feet below ground surface, with most in the nine to ten foot depth range. The probe tip was placed in the middle of approximately one foot of silica sand pack. One foot of granular bentonite was placed above the sand pack, followed by hydrated bentonite to within approximately one foot of ground surface. Silica sand was then placed above the hydrated bentonite to the surface. A gas-tight fitting was installed at the top of the sampling tube and a flush-mount surface completion installed. Two soil vapor probes (i.e., SGCA07 and SGCA19) were replaced by LAC prior to sampling activities.

Soil vapor samples were collected using current state of the art procedures. During soil vapor sampling activities, a clean, small plastic or stainless steel shroud with two small ports was placed over each soil vapor probe and weighted down. An air-tight seal of foam was placed on the ground surface around the edge of the shroud where it contacted the ground. The existing soil vapor probe tube, which was fitted with a metallic Swagelok® fitting, was extended above ground surface with a clean length of Nylaflow® tubing and fitted with an air-tight valve. All connections were made inside/beneath the shroud to verify that the connections/seals were air-tight.

Each soil vapor tube, connected to an air-tight valve, was then connected with a tedlar bag attached to one side of the valve and the sampling tube on the other side of the valve (both outside of the shroud). Prior to purging or sampling activities, helium tracer gas was released via a small diameter tube through a port in the shroud into the enclosure beneath the shroud. A sample of the air inside the shroud was measured through the second port using a portable helium detector to determine the concentration of helium within the enclosure beneath the shroud.

As historically done, soil vapor probes were purged (i.e., up to 1.0 L) at a flow rate of 100 to 200 mL per minute, through the shroud into a 60 ml calibrated gas-tight syringe and transferred to the tedlar bag. The tedlar bag was then connected to a portable helium detector to measure for the presence of helium gas in the purged vapor. If high concentrations (>10% of the shroud concentration) of helium were observed in the purge vapor, the soil vapor probe seal was checked and/or enhanced to reduce the infiltration of ambient air into the enclosure and another sample collected. If helium concentrations were less than 10%, a soil vapor sample was collected for analysis. Upon completion of sampling activities, all soil vapor probes were closed and secured.

Soil vapor samples were collected over approximately a 10 minute time period utilizing dedicated, laboratory-set regulators and 1 L Summa® (or equivalent) canisters supplied and individually certified clean to reporting limit levels by Air Toxics. Each canister had an initial field vacuum reading of at least

Page 19: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 13

23 inches Hg prior to sampling and had a final field vacuum reading of 3 inches Hg or greater upon the completion of sample collection.

Samples were shipped to the laboratory within three days of sampling so that no sample exceeded the 30-day holding time for the TO-15 method. Full chain of custody documentation was maintained for all canisters from time of shipping from the laboratory to the time of analysis. Soil vapor sample locations are shown on Figure 1. Soil vapor collection information is summarized on the Soil Vapor Sample Collection Log provided in Appendix B.

3.5 GROUNDWATER SAMPLE COLLECTION

Groundwater samples from 13 monitoring wells (ten alluvial and three in the Denver Formation) were collected within the Study Area to assess the current concentrations of COCs. Two wells (i.e., MWCA13 and IM-9) were destroyed after the 2007 indoor air study and were replaced by LAC prior to January 2010 sampling activities. Groundwater samples from 13 monitoring wells were collected by LAC personnel as part of the January 2010 OU5 Main TCE Plume Closure /Performance GMP and the alluvial well samples have been used to assess the relationship between changes in VOC concentrations in groundwater and indoor air, sub-slab vapor, and soil vapor samples.

Groundwater samples were analyzed for VOCs by EPA Method 8260B, following the procedures set forth in the GMP work plans. Monitoring well locations are shown on Figure 1.

Page 20: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 14

4 LABORATORY PROCEDURES

This section presents a summary of laboratory procedures for indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater samples.

4.1 INDOOR AIR, OUTDOOR AIR, SUB-SLAB VAPOR, AND SOIL VAPOR SAMPLES

All samples (indoor air, outdoor air, sub-slab vapor, and soil vapor) were analyzed using a modified Method TO-15 (USEPA, 1999a), for the 10 COCs indicated in Table 2, by Air Toxics, Inc. using internal standard operating procedures (SOPs). Specific analytical procedures are described below.

The laboratory reporting limits (RLs) are initially established for an undiluted laboratory standard. When a sub-atmospheric integrated sample is collected, the canister does not fill completely. A diluent gas is added to pressurize the canisters for analysis. Consequently, sample RLs can vary for each sample, depending on sample volume and sample matrix effects, as shown on Table 3.

RLs for the study are low enough for comparison to CDPHE policy action levels and/or levels that have been used at other sites in Colorado. They are the best available CDPHE-approved values for evaluating risks to human health from indoor air. The RL for TCE in indoor air is less than the 0.8 micrograms per cubic meter (μg/m3) residential action level in the CDPHE’s 2004 TCE interim policy, and is also well within the range of typical background air. The RL for PCE in indoor air is well below the residential action level of 15.5 μg/m3 CDPHE 2006). The 0.8 μ g/m3 TCE and 15.5 μg/m3 PCE action levels are defined in the respective policies as the level at which mitigation may be required if a subsurface source is indicated and below which continued monitoring would not be required. All indoor air RLs for other COCs are below the CDPHE action levels established for the Redfield Rifle Scope Site. The Redfield Site action levels are comparable to those used at other sites in Colorado and provide the best guidelines for comparison.

Sub-slab vapor and soil vapor RLs are considered to be acceptable, considering the minimum 100 fold attenuation observed between historical sub-slab vapor and paired indoor air samples in the Study Area. For TCE, the sub-slab and soil vapor results have been reported down to the method detection limit (MDL) with a “J” qualifier added for values between the RL and MDL to indicate an estimated value.

Page 21: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

Table 3. Sample Reporting Limits for Air and Vapor Samples

Volatile Organic Compound Indoor/Outdoor Air Sample RL

(μg/m3)

Soil Vapor and Sub-Slab Vapor Sample

RL (μg/m3)

CDPHE Action Level

(μg/m3) Vinyl Chloride 0.039 to0.073 5.7 0.72

1,1-Dichloroethene (1,1-DCE) 0.06 to 0.11 5.7 5.0 Trichloroethene (TCE) 0.027 to 0.046 7.8 (MDL=1.12) 0.8**

Tetrachloroethene (PCE) 0.21 to 0.39 9.8 (MDL=1.02) 15.5*** cis-1,2-Dichloroethene (cis-1,2-DCE) 0.12 to 0.22 5.7 NA trans-1,2-Dichloroethene (trans-1,2-

DCE) 0.6 to 1.1 5.7 NA

1,1-Dichloroethane (1,1-DCA) 0.062 to 0.12 5.8 510 1,2-Dichloroethane (1,2-DCA) 0.062 to 0.12 5.8 0.69

1,1,1-Trichloroethane (1,1,1-TCA) 0.16 to 0.31 7.9 1000 1,1,2-Trichloroethane (1,1,2-TCA) 0.16 to 0.31 7.9 NA

Notes: Residential Action Levels from the July 31, 2007 Hazardous Communication letter for the Redfield Site **CDPHE, 2004 and Redfield letter (2007) ***CDPHE, 2006 and Redfield letter (2007) MDL = Minimum detection limit, RL = Reporting Limit. Any concentrations between the MDL and the RL were reported as an estimated concentration. NA = Not Applicable.

EnviroGroup Limited 15

Page 22: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 16

4.2 GROUNDWATER SAMPLES

Laboratory analysis for groundwater samples were completed in accordance with the GMP work plans, using EPA Method 8260B. The maximum reporting limits are provided in Table 4 and are at or below the Colorado Basic Standards for Groundwater (CBSGW),

Table 4. Sample Reporting Limits for Groundwater

Volatile Organic Compound Sample Reporting Limits (μg/L)

CBSGW* (μg/L)

Vinyl Chloride 2 2 1,1-Dichloroethene (1,1-DCE) 2 7

Trichloroethene (TCE) 2 5 Tetrachloroethene (PCE) 2 5

cis-1,2-Dichloroethene (cis-1,2-DCE) 2 70 trans-1,2-Dichloroethene (trans-1,2-DCE) 2 100

1,1-Dichloroethane (1,1-DCA) 2 NA 1,2-Dichloroethane (1,2-DCA) 2 5

1,1,1-Trichloroethane (1,1,1-TCA) 2 200 1,1,2-Trichloroethane (1,1,2-TCA) 2 5

Notes: *CBSGW – Colorado Basic Standard for Groundwater. NA = Not Applicable.

Page 23: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 17

5 QUALITY ASSURANCE/QUALITY CONTROL

This section addresses quality control issues associated with field and laboratory investigations for indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater. The quality assurance objective for field and laboratory investigations is to provide defensible analytical data that are accurate, precise, representative, comparable between labs and complete to the degree defined by the project QA/QC Plan and required for the performance of monitoring obligations, the evaluation of remedial alternatives, and the design of remedies.

5.1 LABORATORY QA/QC REQUIREMENTS

Laboratory QA/QC analytical results were reviewed during data validation. Results indicated acceptable accuracy and precision in the analyses.

The two laboratory duplicates for soil vapor yielded excellent agreement for the two compounds detected above reporting limits (TCE and PCE), with Relative Percent Differences (RPDs) of less than 14%.

The two laboratory duplicates for sub-slab vapor yielded excellent agreement for the one compound detected above reporting limits (TCE), with RPDs of less than 4%.

Laboratory duplicates for indoor air generally yielded excellent agreement for the three compounds detected above reporting limits (TCE, PCE and 1,2-DCA), with RPDs of less than 5%, except for one of the three lab duplicates where the RPD for 1,2-DCA was 34%. The 1,2-DCA results for this sample pair were just slightly above the reporting limit and larger variability is to be expected at these low concentrations.

5.2 FIELD QA/QC REQUIREMENTS

Field QA/QC samples (i.e. duplicates and outdoor air samples) and canister vacuums were reviewed to assure compliance with the project QA/QC plan.

5.2.1 Trip Blanks

Trip blanks were not submitted for the soil vapor, sub-slab vapor or indoor air sampling program because the laboratory selected used individually certified clean Summa canisters and flow

Page 24: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 18

regulators. Trip blanks were not considered to be necessary when such cleaning certification was provided.

5.2.2 Field Duplicates

Indoor air field duplicates consisted of two canister samples collected simultaneously and side by side. In the case of soil vapor and sub-slab vapor samples, simultaneous Summa canister samples were collected through a “T” arrangement. Field duplicates are prepared to evaluate sampling technique and laboratory procedures through the analysis of representative samples obtained from a relatively homogenous medium. Two indoor air, four sub-slab vapor, two soil vapor, and one groundwater field duplicate samples were collected during the 2010 investigation.

The two field duplicates for soil vapor yielded acceptable agreement for the two compounds detected above reporting limits (TCE and PCE), with Relative Percent Differences (RPDs) of 40% to 50.5%.

The four field duplicates for sub-slab vapor yielded excellent agreement for the one compound detected above reporting limits (TCE), with RPDs of less than 15%.

Field duplicates for indoor air generally yielded excellent agreement for the three compounds detected above reporting limits (TCE, PCE and 1,2-DCA), with RPDs of less than 22%, except for one of the two field duplicates where the RPD for 1,2-DCA was 56%. The 1,2-DCA results for this sample pair were just slightly above the reporting limit and larger variability is to be expected at these low concentrations.

The field duplicates for groundwater yielded identical results for the one compound detected above reporting limits (TCE).

5.2.3 Ambient Air

Twenty-four hour ambient air (i.e., outdoor air) samples were to be collected during each day of indoor air sampling, contemporaneous with the indoor air sampling, for comparison to the indoor air results. Five outdoor air samples were collected during the investigation. Due to the extended time frame of indoor air sampling, Summa canisters were unavailable for outdoor air sampling on two days when indoor air samples were collected. The five outdoor air samples collected are considered to be adequate to represent the range of outdoor air VOC concentrations during the indoor air sampling program.

Page 25: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 19

5.2.4 Canister Vacuums

Initial field vacuums should be greater than 24 inches Hg for canisters received from labs at sea level. One soil gas sample (EGSGCA14) had an initial field vacuum of -23 inches Hg possibly indicating minor canister leakage during shipment to the field. Insufficient spare canisters were available, so this canister was used for sampling. This sample may have a slight low bias. Two soil gas samples had low laboratory vacuums compared to final field vacuums (SGCA11 and SGCA16) indicating that the canisters might have leaked during shipment back to the laboratory. Given the relatively high TCE concentrations in these soil vapor samples, such leakage may have resulted in a low bias in the results. Two indoor air samples (LAI08 and LAI17) had low laboratory vacuums compared to final field vacuums, indicating that the canisters might have leaked during shipment back to the laboratory. Although sample LAI17 agrees fairly well with the duplicate at this location, the higher TCE concentration from the duplicate was used for comparison purposes. Sample LAI08 from the basement of 1238 Uinta may be biased somewhat low due to potential canister leakage during shipment. The higher TCE concentration from the first floor sample was utilized for comparison purposes at this home.

5.3 DATA VALIDATION

Laboratory analytical data were validated and verified in terms of their ability to satisfy the data quality objectives for accuracy, precision and completeness specified by the project QA/QC Plan and the analytical laboratory. Data validation was completed by trained EnviroGroup personnel who were not involved with the sample collection. Validation flags applied to the results are explained in the footnotes to each table.

Page 26: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 20

6 INVESTIGATION RESULTS

This section summarizes the results of the indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater investigations conducted as part of this Indoor Air Study.

6.1 INDOOR AIR INVESTIGATION

This section presents the results of the January 2010 indoor air, outdoor air, and sub-slab vapor sampling in the study area.

6.1.1 Indoor Air Analytical Results

The results from indoor air samples collected by EnviroGroup from nine homes in January 2010 are shown on Figure 2 and in Table 5. Of the ten indoor air COCs analyzed, six were detected (all except 1,1,2-TCA, cis-1,2-DCE, trans-1,2-DCE and 1,1-DCE) in one or more samples. As with previous sampling, TCE and PCE were the dominant VOCs present in indoor air, with TCE concentrations ranging from 0.053 to 1.7 µg/m3 and PCE from 0.24 to 6.6 µg/m3.

Trace levels of 1,1,1-TCA similar to those in outdoor air were present in all samples. Low levels of vinyl chloride were detected in samples from three homes (1238 Uinta, 1330 Ulster, and 1222 Uinta). One low level detection of 1,1-DCA, in the basement sample from 1222 Uinta, is considered anomalous. All indoor air samples except one had detectable results for 1,2-DCA, with concentrations ranging from 0.068 to 0.68 µg/m3. Most samples had 1,2-DCA concentrations similar to outdoor air, except the first floor samples from 1330 Ulster, 1235 Valentia, and 1350 Ulster. In all three of these cases the first floor results were substantially larger than those for the basement or crawl space. The average TCE concentration in the 11 basement indoor air samples was 0.395 µg/m3. Note that only two homes (1282 Uinta and 1238 Uinta) had basement TCE concentrations above 0.33 µg/m3. The average PCE concentration in the 11 basement indoor air samples was 0.92 µg/m3.

The average TCE concentration in the nine first floor indoor air samples was 0.394 µg/m3. The average PCE concentration in the nine first floor indoor air samples was 0.71 µg/m3. Most of the homes sampled had PCE concentrations similar to outdoor air, with a few exceptions. Note that at 1353 Uinta Street, the PCE in the basement sample was substantially larger (more than 4 times higher) than the result for the crawl space or for the first floor. This strongly suggests an indoor

Page 27: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 21

source, consistent with the storage of numerous paints and some spot removers in this basement (see Appendix A). Likewise, at 1282 Uinta Street, the January 19th first floor sample had substantially higher (more than 4 times higher) PCE than the crawl space or basement sample. This also strongly suggests an indoor source. For TCE, the first floor indoor air results were comparable to those in the basement, or crawl space when present, suggesting the lack of notable indoor air sources of TCE on the first floor of these homes.

The average TCE concentration in the three crawl space indoor air samples was 0.46 µg/m3. The average PCE concentration in the three crawl space indoor air samples was 0.57 µg/m3. For the three locations with crawl space data, the basement and first floor TCE results were very comparable to the crawl space results, suggesting minimal attenuation from crawl space to indoor air.

6.1.2 Outdoor Air Analytical Results

The results from outdoor air samples collected by EnviroGroup from the vicinity of five homes in January 2010 are shown in Table 5. Of the ten indoor air COCs analyzed, only four were detected (1,1,1-TCA, 1,2-DCA, PCE and TCE) in one or more samples. As with previous sampling, PCE was the dominant VOC present in outdoor air, with concentrations ranging from 0.23 to 0.49 µg/m3, similar to that in most of the homes tested. The average PCE concentration in these samples was 0.33 µg/m3. TCE concentrations ranged from 0.029 to 0.089 µg/m3, with an average of 0.052 µg/m3. Trace levels of 1,1,1-TCA (average of 0.046 µg/m3) and 1,2-DCA (average of 0.11 µg/m3) were also consistently present.

6.1.3 Sub-Slab Vapor Analytical Results

The results from sub-slab vapor samples collected by EnviroGroup from nine homes in January 2010 are shown on Figure 3 and in Table 6. Of the ten indoor air COCs analyzed, only two were detected (PCE and TCE) in one or more samples. As with previous sampling, TCE was the dominant VOC present in sub-slab vapor, with concentrations ranging from below detection (< 1.1 µg/m3) to 260 µg/m3. The average TCE concentration in these 9 sub-slab vapor samples was 84 µg/m3. PCE concentrations were all below 25 µg/m3 in these samples, and were typically about 10% of the associated TCE concentration.

Page 28: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 22

6.2 SOIL VAPOR INVESTIGATION

The results from soil vapor samples collected by EnviroGroup from 15 permanent, deep (eight to ten foot) soil vapor points in January 2010 are shown on Figure 4 and in Table 7. Of the ten indoor air COCs analyzed, only six were detected (1,1-DCE; 1,1,1-TCA; 1,2-DCA; cis-1,2-DCE, PCE and TCE) in one or more samples. As with previous sampling, TCE was the dominant VOC present in soil gas, with concentrations ranging from below detection (< 7.6 µg/m3) to 1200 µg/m3. The average TCE concentration in these 15 soil vapor samples was 218 µg/m3. PCE concentrations were all below 120 µg/m3 in these samples, and were typically about 10% of the associated TCE concentration. A few of the samples with the higher TCE concentrations yielded trace (below reporting limit) concentrations of 1,1-DCE, cis-1,2-DCE and 1,1,1-TCA. One sample, EG-SGCA-11, yielded trace levels of 1,2-DCA. This sample is suspected of sampling canister leakage during shipment to the laboratory, therefore the 1,2-DCA result is suspect.

6.3 GROUNDWATER INVESTIGATION

The results from groundwater samples collected by another LAC contractor in January 2010 are presented in Table 8 and Figure 5. Of the ten indoor air COCs analyzed, only three were detected (cis-1,2-DCE, PCE and TCE) in one or more samples. As with previous sampling, TCE was the dominant VOC present in groundwater, with concentrations ranging from below detection (< 2 µg/L) to 32 µg/L in alluvial groundwater. The average TCE concentration in the ten alluvial wells was 11 µg/L.

PCE concentrations were all below detection in the ten alluvial wells, consistent with its low abundance relative to TCE. PCE and cis-1,2-DCE were only detected in one deep (Denver Formation) bedrock well (of a nested well pair) at levels below the MCLs.

Page 29: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 23

7 GROUNDWATER-TO-INDOOR AIR PATHWAY EVALUATION

This section presents an evaluation of the groundwater-to-indoor air, or vapor intrusion, pathway including a comparison of indoor air concentrations to screening levels (Section 7.1), a comparison of indoor air to background concentrations (Section 7.2), a comparison of indoor air to subsurface concentrations (Section 7.3), an evaluation of current and historical attenuation factors between indoor air and other media (Section 7.4), and a trend analysis of all groundwater, soil gas, sub-slab vapor and indoor air results for TCE (Section 7.5).

7.1 INDOOR AIR VS SCREENING LEVELS

CDPHE has established risk management levels for TCE in indoor air in their Proposed Policy On Interim Risk Evaluation And Management Approach For TCE (2004), and these levels are used throughout this report as a point of reference for understanding the effectiveness of the remediation program. This section presents comparisons of indoor air (including crawl space) concentrations to available CDPHE residential action levels in order to provide context for the results. As described in Section 4.1, these values are the best available for evaluating risks in indoor air. All indoor air results for 1,1-DCE, 1,1-DCA, 1,1,1-TCA, 1,2-DCA, PCE, trans-1,2-DCE, and vinyl chloride were well below CDPHE action levels shown in Table 3. Similarly, all results for 1,1,2-TCA were non-detectable.

Two homes (1238 and 1282 Uinta Street) have TCE results above the CDPHE action level of 0.8 µg/m3. These samples were collected during the winter, and therefore most likely represent the maximum annual indoor air concentration. As noted in Section 2.1, based on the seasonal (bimonthly) sampling at several of these homes in 2000-2001, winter indoor air concentrations are approximately twice the annual average concentration in a home (see table 5-1 of Versar, 2003). For long-term exposure estimates (30 years) the annual average is a more representative exposure concentration. Based on the Versar data, the resulting calculated current annual average TCE concentrations at the two homes with the highest TCE results in 2010 (1238 and 1282 Uinta) would be 0.85 µg/m3 and 0.55 µg/m3, respectively.

7.2 INDOOR VS BACKGROUND CONCENTRATIONS

This section presents comparisons of indoor air to background concentrations, including outdoor air and background indoor air data.

Page 30: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 24

7.2.1 Indoor Air to Outdoor Air Concentration Comparison

The indoor air TCE results for 1330 Ulster, 1305 Uinta, 1235 Valentia, and 1350 Ulster are only marginally higher than the outdoor air TCE concentrations (average of 0.052 µg/m3), suggesting a dominant outdoor source for TCE in these four homes. The remaining five homes have indoor air TCE results greater than the outdoor air, at least in basement samples.

Except for the anomalously high first floor results at 1282 Uinta and 1353 Uinta, and the anomalous basement PCE result at 1353 Uinta, the indoor air PCE results are nearly identical to the outdoor air PCE results for five of the remaining six homes. The PCE results at 1238 Uinta are slightly above those in outdoor air. Only the home at 1238 Uinta appears to have any measurable vapor intrusion contribution to indoor air PCE concentrations, although these concentrations are well below the CDPHE action levels.

As noted previously, the majority of the 1,2-DCA results in indoor air are similar to the outdoor air results with a few homes having indications of indoor sources. Trace levels of 1,1,1-TCA, similar to those in outdoor air, are present in all samples.

7.2.2 Indoor Air to Background Indoor Air Comparison

Low levels of vinyl chloride occur in samples from two homes (1238 Uinta and 1222 Uinta). These low concentrations are typical of background indoor sources (Kurtz and Folkes, 2002; Foster and others, 2002a). One low level detection of 1,1-DCA, in the basement sample from 1222 Uinta, is considered anomalous. All except one indoor air sample had detectable results for 1,2-DCA, with concentrations ranging from 0.068 to 0.68 µg/m3. Most samples had 1,2-DCA concentrations similar to outdoor air, except for the first floor samples from 1330 Ulster, 1235 Valentia, and 1350 Ulster. In all three of these cases the first floor results were substantially larger than those for the basement or crawl space. This suggests an indoor source for 1,2-DCA consistent with recent findings about indoor sources for 1,2-DCA (Kurtz et.al., 2010). Note that, with one exception, 1,2-DCA is not present in soil vapor or sub-slab vapor, and it has not been detected in alluvial groundwater.

The three anomalously high PCE results (from 1.5 to 6.6 µg/m3) are comparable to typical background indoor air ranges (Kurtz and Folkes, 2002; Foster and others, 2002a). Note that at 1353 Uinta Street, the PCE in the basement sample is substantially larger than the result for the crawl space or for the first floor. This strongly suggests an indoor source consistent with the numerous products stored in the basement of this home (Appendix A). Likewise, at 1282 Uinta

Page 31: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 25

Street, the January 19th first floor sample had substantially higher PCE than the crawl space or basement sample. This also strongly suggests an indoor source. Note that PCE has not been detected in alluvial groundwater wells in the study area.

For TCE, the first floor indoor air results are comparable to those in the basement, or crawl space when present, suggesting the lack of notable indoor air sources of TCE on the first floor of these homes. Most of the TCE results are consistent with background indoor air levels (Foster and others, 2002b), except for those at 1238 Uinta and 1282 Uinta. The latter two homes are the only homes with an apparent vapor intrusion contribution of TCE above typical background levels.

The home at 1238 Uinta is the only one with an apparent slight vapor intrusion contribution to PCE, although the results (0.45 and 0.53 µg/m3) are well within typical background indoor air ranges and the maximum possible vapor intrusion contribution is substantially less than the CDPHE action level of 15.5 µg/m3.

7.3 INDOOR AIR VS SUBSURFACE CONCENTRATIONS

As an essential part of the groundwater-to-indoor air pathway evaluation this section compares indoor air concentrations to sub-slab vapor, soil vapor, and groundwater concentrations. In addition, sub-slab vapor concentrations are compared to nearby soil vapor concentrations.

7.3.1 Comparison of Indoor Air to Sub-slab Vapor Concentrations

The two homes with the highest indoor air concentrations of TCE (1282 Uinta and 1238 Uinta) also have the highest sub-slab vapor concentrations of TCE. Likewise, with the exception of 1235 Uinta, the three homes with the lowest indoor air TCE concentrations (1330 Ulster, 1305 Uinta, and 1350 Ulster) also have the lowest sub-slab vapor TCE concentrations. The sub-slab TCE is not detectable at 1350 Ulster, suggesting that the measured indoor air TCE at this home is completely due to background sources (probably largely outdoor air in this case). The homes at 1222 Uinta, 1235 Uinta, and 1353 Uinta all have slightly elevated indoor air TCE levels (ranging from 0.14 to 0.33 µg/m3), with higher concentrations in the basement than on the first floor. This suggests a potential sub-surface source for TCE. The sub-slab to indoor air attenuation factors for 1222 Uinta and 1235 Uinta are consistent with historical values at these two homes, when sub-slab concentrations were higher than at present, suggesting that a minor vapor intrusion contribution to TCE is present in these two homes. However, the apparent sub-slab to indoor air attenuation for the 2010 result at 1353 Uinta is significantly less than that for the historical data

Page 32: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 26

when sub-slab concentrations were higher. This suggests that a substantial portion of the measured indoor air TCE at this home is due to outdoor air and indoor sources.

As noted previously, PCE concentrations in the sub-slab were all below 25 µg/m3, and were typically about 10% of the associated TCE concentration. Based on a simple ratio comparison, one would expect about 10% as much PCE in indoor air as TCE, if the source were vapor intrusion. Based on the measured indoor air TCE concentrations, the maximum vapor intrusion contribution to PCE (at 1238 Uinta) would be approximately 0.17 µg/m3, well below the screening level of 15.5 µg/m3 . All other indoor air locations would be predicted to have a negligible vapor intrusion contribution to PCE.

7.3.2 Comparison of Indoor Air to Soil Vapor Concentrations

The two homes with the highest indoor air concentrations of TCE (1282 Uinta and 1238 Uinta) are proximal to two of the four soil vapor locations (near homes) with the highest TCE concentrations. Likewise, with the exception of 1235 Uinta, the five homes with the lowest indoor air TCE concentrations (1330 Ulster, 1305 Uinta, 1350 Ulster, 1353 Uinta, and 1235 Valentia) also have the lowest nearby soil vapor TCE concentrations. The indoor air results for 1222 Uinta are somewhat low compared to the soil vapor points to the west of the home, but they may reflect the very low soil vapor TCE concentrations to the east of this home (see Figure 3). Likewise, the indoor air TCE results at 1235 Uinta are low compared to other locations with similar nearby soil vapor TCE concentrations. In this case, it is probable that the sub-slab depressurization system had not been off for a long enough time period (e.g., more than one week) to allow the indoor air and sub-slab vapor concentrations to re-equilibrate.

As noted previously, PCE concentrations in the soil vapor in the immediate vicinity of homes (excluding SGCA-06) were all below 70 µg/m3, and were typically about 10% of the associated TCE concentration, similar to the sub-slab vapor results.

7.3.3 Comparison of Sub-slab Vapor to Soil Vapor Concentrations

The two homes with the highest sub-slab vapor concentrations of TCE (1282 Uinta and 1238 Uinta) are proximal to two of the four soil vapor locations (near homes) with the highest TCE concentrations. The sub-slab TCE at these two homes has the same concentration as the nearby soil vapor, within a factor of two. The sub-slab TCE results for 1222 Uinta are intermediate between the concentrations in surrounding soil vapor. The sub-slab results for 1350 Ulster are

Page 33: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 27

lower than the nearby soil gas point (SGCA10), but this home may be beyond the edge of the plume based on the historical near absence of TCE in the sub-slab at this home. The sub-slab TCE results for 1235 Valentia are substantially higher than that in the two nearby soil vapor points, although the nearby alluvial groundwater has comparable TCE concentrations to those near other homes tested. The historical data for this location in 1998 yielded low indoor air and very low sub-slab TCE concentrations suggesting that higher soil gas concentrations may have diffused towards this location since 1998. The sub-slab TCE results for 1235 Uinta are anomalously low compared to that nearby soil vapor and compared to historical sub-slab results. The sub-slab TCE may not have sufficiently rebounded in the one week after the radon system was turned off and the samples were collected. The indoor air TCE results for this home are also anomalously low, suggesting that insufficient time was allowed for the sub-slab and indoor air at this home to re-equilibrate after the radon system was turned off. The remaining homes have sub-slab TCE concentrations comparable to those in adjacent soil vapor.

7.3.4 Comparison of Indoor Air to Groundwater Concentrations

Alluvial groundwater TCE concentrations show little variation within the vicinity of the residences studied (<2 to 14 µg/L), with most in the range of 6 to 12 µg/L. No clear spatial relationship is apparent between January 2010 groundwater concentrations and concurrent indoor air concentrations, other than generally higher indoor air concentrations along the center line of the groundwater plume. This unclear spatial relationship between concentrations in the two media is likely due to groundwater response to remedial treatment with insufficient time for the effects to diffuse to the sub-slab and then indoor air. The closer correspondence of soil vapor and sub-slab vapor may be a reflection of this time lag for diffusion from the water table.

PCE was not detected in any of the groundwater samples collected from the ten alluvial wells in the Study Area. Based on the above, no significant vapor intrusion-derived PCE would be expected in indoor air.

7.4 ATTENUATION FACTORS

The reduction in vapor phase concentration from one media to another is called attenuation. When expressed as a ratio of the concentration in one media (indoor air) compared to another, this is termed an “attenuation factor”. Attenuation factors for sub-slab vapor to indoor air, soil vapor to indoor air, groundwater to soil vapor, and groundwater-derived vapor to indoor air are

Page 34: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 28

calculated for current and historical data as part of the vapor intrusion pathway evaluation. The evaluation of attenuation factors provides context for the data by allowing comparisons across the study area and to data at other sites around the country. It also provides an understanding of how the site specific data compare to standard default assumptions for the groundwater-to-indoor air pathway, such as those incorporated into those utilized by EPA and CDPHE Vapor Intrusion Guidances for groundwater to indoor air, soil vapor to indoor air, and sub-slab vapor to indoor air attenuation factors.

7.4.1 Attenuation from Sub-slab Vapor to Indoor Air

Attenuation factors for TCE in sub-slab vapor compared to indoor air from the January 2010 sampling event range from 9 x 10-4 to 1.1 x 10-2, and average 5.3 x 10-3 (Table 9). These ranges are very similar to those determined from previous results at these homes, and are nearly identical for individual homes (within a factor of two) as shown in Table 9, with the exception of the 1998 results for 1235 and 1329 Uinta. These two 1998 apparent attenuation factors are anomalously small compared to subsequent sampling events at these two homes and are considered to be non-representative. This finding of anomalously low indoor air concentrations is consistent with the open house sampling conditions documented for these two homes in the 1998 sampling event (Versar, 2001 Table 6-14). Note that the range of sub-slab attenuation factors are substantially smaller than the default sub-slab to indoor air attenuation factor of 0.1 used in the 2002 EPA Vapor Intrusion Guidance, but are comparable to the median sub-slab to indoor air attenuation factor in the 2010 EPA VI database.

7.4.2 Attenuation from Soil Vapor to Indoor Air

Attenuation factors for TCE in soil vapor points nearest the homes compared to indoor air from the January 2010 sampling event range from 1.1x 10-3 to 1.7 x 10-2 (Table 10), similar to the sub-slab to indoor air attenuation factors. These ranges are very similar to those determined from previous results, and are nearly identical for individual homes (within a factor of two) as shown in Table 10. The one location with the lowest apparent attenuation (1235 Valentia) is anomalous in that the sub-slab vapor TCE concentration is nearly twenty times higher than the nearby soil gas concentration. It should be noted that the indoor air TCE results at this home are only slightly greater than the outdoor air TCE and are well within the range of typical indoor air background (Kurtz and Folkes, 2002; Foster and others, 2002). No measurable vapor intrusion related TCE appears to be present in the indoor air at this home.

Page 35: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 29

7.4.3 Attenuation from Groundwater to Soil Vapor

Groundwater derived vapor concentrations at equilibrium are determined by multiplying the groundwater concentration by the Henry’s Law Constant for a compound (adjusted for the groundwater temperature) and converting units to µg/m3 from µg/L. These calculated equilibrium soil gas concentrations (at the water table) can be directly compared to the measured soil gas concentrations at approximately eight to ten foot depth. The ratio of measured soil gas TCE to the calculated groundwater-derived soil gas is the groundwater to soil gas attenuation factor. For the January 2010 sampling event these ranged from 1.5 x 10-3 to 2.5 x 10-1, and average 8.25 x 10-2 (Table 11). Similar results were found for the 2007 paired groundwater and soil gas sampling event (Table 11).

The measured soil gas TCE concentrations are about 10% of what would be predicted just above the water table for equilibrium partitioning according to Henry’s Law, probably due to attenuation in the vadose zone. Many sites report similar findings of approximately 10% of the expected equilibrium soil gas concentration for deep soil gas samples.

7.4.4 Attenuation from Groundwater to Indoor Air

Attenuation factors for TCE in groundwater-derived vapor compared to that measured in indoor air from the January 2010 sampling event range from 2.6 x 10-5 to 8.4 x 10-4, with an average of 2 x 10-4 (Table 12). These ranges are very similar to those determined from previous groundwater and indoor air sampling events (Table 12). The average groundwater to indoor air attenuation factor is nearly an order of magnitude less than the 2002 EPA default attenuation factor of 10-3, but is approximately equivalent to the 75th percentile of the 2010 EPA VI Database attenuation factor for groundwater to indoor air and essentially equivalent to the median attenuation for the coarser soil types in the EPA Database.

7.5 TREND ANALYSIS

Groundwater remediation activities over the past six years have resulted in substantial reductions in VOC concentrations in alluvial groundwater in this area. The average TCE concentration in the ten alluvial wells was 11 µg/L in January 2010 versus 25 µg/L for the ten alluvial wells sampled in 2007 and approximately 110 µg/L for the two center plume alluvial wells in existence in 1996-2001. A comparison just for the two center plume alluvial wells in existence in 1996-2001 (MWOB04 and MWOB21) to data for 2010 yields identical results for the average

Page 36: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 30

concentrations at different time periods. All media have shown substantial reductions in VOC concentrations since 1998 and are discussed more fully below.

7.5.1 Groundwater Concentration Trends over Time

Time-concentration trends for TCE for the individual wells are shown overlain in Figure 6. From 2001 to 2007 average groundwater TCE concentrations decreased approximately 60% for the two alluvial wells tested in both events (Table 13). From 2007 to 2010 average groundwater TCE concentrations were reduced approximately 57% for the ten alluvial wells sampled in both events. The reductions typically ranged from 50% to 75% for these wells. However, three wells showed increased concentrations in 2010 compared to 2007 (MWOB22 [MWOB22R], IM-9 [MWCM14], and B-1), although these increases were generally small (< 8.0 µg/L). For two wells, MWOB22R and MWCM14, this could be due to lithologic variations over the screen intervals of the relocated wells. For two of the three alluvial wells with data from 1998 to 2010, the percent reductions in TCE range from 90 to 96%.

7.5.2 Soil Vapor Concentration Trends over Time

A time trend graph for TCE in all of the individual soil vapor points is shown in Figure 7. From 1998 to 2007 average soil vapor TCE concentrations decreased approximately 40% to 65% for the five locations tested in both events (Table 14). From 2007 to 2010 average soil vapor TCE concentrations decreased approximately 77%, for the eleven locations where the 2007 concentrations were greater than 8.0 µg/m3. The reductions ranged from 65% to 95% for these locations. Excluding two anomalously low results from the 1998 data (SGOB27 and SGOB32), the remaining six soil vapor locations showed an average reduction of 93% from 1998 to 2010, with a range of 85% to 98%.

7.5.3 Sub-slab Vapor Concentration Trends over Time

From 2001 to 2007 average sub-slab vapor TCE concentrations decreased approximately 40% to 65% for three of the five homes tested in both events (Figure 8). From 2001 to 2010 average sub-slab vapor TCE concentrations decreased approximately 70% for the three homes tested in both events (Table 15). Note that the 2010 results for 1235 Uinta are anomalously low (1% of the 2001 value) compared to the other three homes, probably due to insufficient time allowed for rebound of sub-slab concentrations after turning off the system a week prior to sampling. Three

Page 37: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 31

of the homes with the highest concentration in 2007 (excluding 1235 Uinta) showed a 65% reduction in TCE concentration from 2007 to 2010.

7.5.4 Indoor Air Concentration Trends over Time

Although all homes were not tested in each study, it can be stated that the average reduction in indoor air TCE concentrations from 1998 (or 2001) to 2010 was approximately 75%. As noted in section 3.1, two of the homes sampled in either 1998 or 2001 (1264 and 1268 Uinta) did not grant access for sampling during either the 2007 or the present study and are not included in tabulations in this report. Note that of the eight homes tested in 1998, two had anomalously low results that are considered to be non-representative (1235 Uinta and 1329 Uinta) as described in Section 7.4.1. Unfortunately, none of the remaining six homes tested in 1998 were sampled in 2001, but it is expected that indoor air TCE concentrations would have shown little change over this time period due to lack of active groundwater remediation during this time period. The 1998 result for 1314 Ulster has no comparison value, because a radon system was operating in this home at the time of the 2007 sampling. The 1998 TCE results for 1235 Valentia and 1350 Ulster are considered to represent background values, as neither home had significant TCE in the sub-slab vapor at that time (Versar, 2001, Table 6-14) and therefore the percent reductions from 1998 are not calculated. The remaining three homes sampled in 1998 (1305 Uinta, 1330 Ulster, and 1353 Uinta) showed reductions of 96%, 64% and 63% respectively in indoor air TCE concentrations from 1998 to 2010 (Table 16). The only one of these homes sampled in 1998 that was sampled in another event besides 2010 (1305 Uinta) showed a reduction in indoor air TCE concentration of 94% from 1998 to 2007. From 2001 to 2007 average indoor air TCE concentrations decreased approximately 45% for the five homes tested in both events. From 2001 to 2010 average indoor air TCE concentrations decreased approximately 76% for the three homes tested in both events (excluding 1235 Uinta). Note that the 2010 results for 1235 Uinta are anomalously low (1% of the 2001 value) compared to the other three homes, probably due to insufficient time allowed for rebound of sub-slab concentrations after turning off the system a week prior to sampling. Two of the three homes with the highest concentration in 2007 (excluding 1235 Uinta) showed approximately a 75% reduction in TCE concentration from 2007 to 2010 (a range of 71 to 83%). The remaining three homes tested in 2010 and 2007 generally had indoor air results close to background or outdoor air levels in 2010 and thus were unable to show further reductions. As a result, these three homes showed lower apparent percentage reductions from 2007 to 2010. As noted above, given the somewhat limited data, it can be stated that the average reduction in indoor air TCE concentration from 1998 (or 2001) to 2010 was approximately 75%.

Page 38: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 32

7.5.5 Comparison of Indoor Air to Sub-slab Vapor

As expected, the reductions over time in indoor air and sub-slab vapor TCE concentration are very similar, with an average reduction of about 70 to 75% since 2001 (Figure 9).

7.5.6 Comparison of Indoor Air to Soil Vapor

The reductions over time in indoor air and soil vapor TCE concentration are fairly similar, with an average reduction of about 75% in indoor air since 2001 and an average reduction of about 93% in soil gas since 1998 (Figure 9).

7.5.7 Comparison of Soil Vapor to Groundwater

As expected, the reductions over time in groundwater and soil vapor TCE concentration are very similar, with an average reduction of about 90% in groundwater since 1998/2001 and an average reduction of about 93% in soil gas since 1998 (Figure 9).

7.5.8 Comparison of Indoor Air to Groundwater

The reductions over time in indoor air and groundwater TCE concentration are fairly similar, with an average reduction of about 75% in indoor air since 2001 and an average reduction of about 90% in groundwater since 2001 (Figures 9 and 10).

The above comparisons of trends and percent reductions in TCE over time suggest that sub-slab vapor and indoor air concentration reductions are lagging the reductions in groundwater and soil vapor, as would be expected theoretically due to the transport time of soil vapors from the water table, i.e., deep soil gas to the sub-slab and then indoor air. Within the next few years it is likely that the sub-slab vapor and indoor air TCE concentrations will also decrease the same amount as that observed in groundwater and soil gas (i.e., approximately 93% since 1998/2001), to the extent that indoor air concentrations are not due to background sources.

The continued action of residual permanganate and natural attenuation is likely to further reduce groundwater and soil gas TCE concentrations. Over time it is also likely that the sub-slab vapor and indoor air TCE concentrations will decrease the same amount as in groundwater and soil gas (i.e., more than the 93% observed since 1998/2001). A 93% reduction in indoor air TCE concentrations since 2001 would result in a maximum indoor air TCE concentration of 0.46 µg/m3 due to vapor intrusion at the home with the highest indoor air TCE concentration (1238

Page 39: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 33

Uinta) measured in 2001 (other than the mitigated home at 1235 Uinta). Greater percentage reductions due to continued decreases in groundwater concentrations would lead to even lower indoor air TCE concentrations.

Page 40: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 34

8 CONCLUSIONS

TCE concentrations in all media (alluvial groundwater, soil gas, sub-slab vapor, and indoor air) showed substantial decreases (75-93%) over the 1998 to 2010 time frame, due to active groundwater remediation and natural attenuation processes. The decreases in the various media generally showed strong correlations. It is expected that continued decreases in TCE concentrations will occur in all media as a result of interactions in the aquifer with residual permanganate and natural attenuation processes and will achieve protection of human health in the near term.

The maximum indoor air TCE concentration in January 2010 was 1.7 µg/m3 (at 1238 Uinta St. 1st floor); only two homes (1238 and 1282 Uinta) had TCE concentrations above the 0.8 µg/m3 CDPHE policy action level. These samples were collected during the winter, and therefore most likely represent the maximum annual indoor air concentration. Based on the seasonal (bimonthly) sampling at these homes in 2000-2001(Versar, 2003), winter indoor air concentrations are approximately 100% above the annual average concentration in a home (see table 5-1 of Versar, 2003). For long-term exposure estimates (30 years) the annual average is a more representative exposure concentration. The resulting calculated current annual average concentrations at the two homes with the highest TCE results in 2010 (1238 and 1282 Uinta) would be 0.85 µg/m3 and 0.55 µg/m3, respectively. Given the observed direct correlation between alluvial groundwater and indoor air concentrations at the site, it would only require an additional 10% decrease (1 ug/L based on the current concentration) in groundwater TCE concentrations to produce annual average indoor air TCE concentrations that fall below 0.8 µg/m3 for each tested home. The expected continued decrease in groundwater TCE concentrations should be able to achieve this result, and be protective of human health, without additional remedial measures.

The measured groundwater to indoor air and sub-slab vapor to indoor air attenuation factors for all of the homes in the study area were in the range of 2.6 x10-5 to 8.4 x10-4, and 9 x10-4 to 1.1 x10-2, which were within the 50th to 75th percentile of the values in the EPA 2010 Vapor Intrusion Database, well below the default attenuation factors of 10-3 and 0.1, respectively. These attenuation factors were consistent for the individual homes in all of the sampling events from 1998 to present. This indicates that attenuation factors elsewhere over the off-site groundwater plume should be comparable, or even lower, as the depth to groundwater increases to the north and increasing thicknesses of fine-grained soils generally occur in the vadose zone and at the water table.

Page 41: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 35

9 REFERENCES

Colorado Department of Public Health and Environment, 2004. Policy on an Interim Risk Evaluation and Management Approach for TCE. August 20.

Colorado Department of Public Health and Environment, 2006. Policy on an Interim Risk Evaluation and Management Approach for PCE. August 17.

Colorado Department of Public Health and Environment, 2007. Risk Communication letter to homeowners at the former Redfield Rifle Scope Site, July 31.

EnviroGroup Limited, 2009. Indoor Air Study Work Plan, Former Lowry Air Force Base, Denver, Colorado. December 9.

Foster, S.J., J.P. Kurtz, and A.K. Woodland. 2002a. Background indoor air risks at selected residences in Denver Colorado. In Proceedings: Indoor Air 2002, the proceedings of the 9th International Conference on Indoor Air Quality and Climate, Monterey, CA, June 30–July 5, p. 932-937.

Foster, S.J., Kurtz, J.P., and Woodland, A.K., 2002b. Residential Background Indoor Air Concentrations of TCE and Implications for Action Levels, in Proceedings Midwestern States Risk Assessment Symposium, July 24-26, 2002, Indianapolis, Indiana, 7p.

Kurtz, J.P., and D.J. Folkes. 2002. Background concentrations of selected chlorinated hydrocarbons in residential indoor air. In Proceedings: Indoor Air 2002, the proceedings of the 9th International Conference on Indoor Air Quality and Climate, Monterey, CA, June 30–July 5, p. 920-925.

Kurtz, J.P., Wolfe, E.M., Woodland, A.K., and Foster, S.J., 2010. Evidence for increasing indoor sources of 1,2-dichloroethane since 2004 at two Colorado residential vapor intrusion sites. Ground Water Monitoring & Remediation, in press.

Lowry Assumption, LLC, 2004. Groundwater Monitoring Program (GMP) Work Plan for Groundwater Cleanup and Landfill Closure at Lowry.

Lowry Assumption, LLC, 2006. Final Phase 2 Corrective Action Plan for Groundwater Remediation at Lowry. December 21.

Lowry Assumption, LLC, 2007. Sampling and Analysis Plan for the Supplemental Investigation, Groundwater to Indoor Air VOC Migration Pathway, Lowry Air Force Base, Colorado. February.

Lowry Assumption, LLC, 2007b.Closure/Performance Groundwater Monitoring Program (GMP), Main TCE Plume, Operable Unit 5. June 20.

Lowry Assumption, LLC, 2008. Final Supplemental Investigation Report Groundwater-To-Indoor Air, VOC Migration Pathway, Main TCE Plume, OU5, Former Lowry AFB, Denver, Colorado, October.

Page 42: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Indoor Air Study Data Summary and Analysis Report December 2010 LO-0671

EnviroGroup Limited 36

Lowry Assumption, LLC, 2010a. Results for the January 2010Semiannual Closure/Performance Groundwater Monitoring Program – Main TCE Plume, Operable Unit 5, Former Lowry AFB, Denver, Colorado, May.

Lowry Assumption, LLC, 2010b. Remedial Progress Assessment and Scope of Work, Operable Unit 5, Former Lowry AFB, Denver, Colorado, October.

United States Environmental Protection Agency, 1999. Compendium Method TO-15, Determination of Volatile Organic Compounds (VOCs) in Air Collected in Specially-Prepared Canisters and Analyzed by Gas Chromatography/Mass Spectrometry (GC/MS), EPA/625/R-96/010b, Center for Environmental Research Information, Office of Research and Development, Cincinnati, Ohio. January.

United States Environmental Protection Agency, 2002. OSWER Draft Guidance for Evaluation the Vapor Intrusion to Indoor Air Pathway from Groundwater and Soils (Subsurface Vapor Intrusion Guidance), EPA 530-D-02-004, November 2002.

United States Environmental Protection Agency, 2009. Regional Screening Level Table Residential Air, April 2009, www.epa.gov/reg3hwmd/risk/human/rb-concentration_table/Generic_Tables/pdf/resair_sl_table_bwrun_APRIL2009.pdf.

United States Environmental Protection Agency, 2010. U.S. EPA’s Vapor Intrusion Database and a Preliminary Evaluation of Attenuation Factors, EPA 530-R-10-002, Office of Solid Waste, March 2010 Draft.

Versar, Inc., 1999. Final Remediation of Heritage Estates Apartment Complex and Evaluation of System Effectiveness Report. August.

Versar, 2001. Final Operable Unit 5 – Groundwater Remedial Investigation, Lowry Air Force Base, Colorado, Appendix K (Groundwater-To-Indoor Air VOC Migration Pathway Investigation Report). May.

Versar, 2003. Revised Draft Final Phase III Groundwater-To-Indoor Air VOC Migration Pathway Investigation Report. June.

Page 43: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

TABLES

Page 44: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 5. 2010 Indoor and Outdoor Air Analytical Results

Page 1 of 1

Sample ID Sample Location Sample Date Sample Level

Indoor AirLAI01 1235 Uinta St 1/15/2010 1st Floor 0.34 0.22 0.051 U 0.080 U 0.081 U 0.16 U 0.045 J 0.15 0.22 U 0.80 U

LAI01 Lab Dup 1235 Uinta St 1/15/2010 1st Floor 0.35 0.21 0.051 U 0.080 U 0.081 U 0.16 U 0.047 J 0.15 0.22 U 0.80 ULAI02 1235 Uinta St 1/15/2010 Basement 0.36 0.24 0.040 U 0.063 U 0.064 U 0.12 U 0.049 J 0.13 0.17 U 0.63 ULAI03 1235 Uinta St 1/15/2010 Basement 0.36 0.33 0.048 U 0.074 U 0.076 U 0.15 U 0.045 J 0.14 0.20 U 0.74 ULAI04 1282 Uinta St 1/19/2010 1st Floor 2.4 1.1 0.053 U 0.082 U 0.083 U 0.16 U 0.051 J 0.082 J 0.22 U 0.82 ULAI05 1282 Uinta St 1/19/2010 Basement 0.64 0.89 0.051 U 0.080 U 0.081 U 0.16 U 0.054 J 0.13 0.22 U 0.80 ULAI06 1282 Uinta St 1/19/2010 Crawl Space 0.53 1.2 0.051 U 0.080 U 0.081 U 0.16 U 0.057 J 0.089 0.22 U 0.80 ULAI23 1282 Uinta St 2/23/2010 Basement 0.24 0.71 0.043 U 0.067 U 0.14 U 0.13 U 0.051 J 0.068 U 0.18 U 0.67 ULAI07 1238 Uinta St 1/20/2010 1st Floor 0.53 1.7 0.06 0.088 U 0.09 U 0.18 U 0.064 J 0.17 0.24 U 0.88 ULAI08 1238 Uinta St 1/20/2010 Basement 0.45 G 1.6 G 0.028 J G 0.060 U 0.062 U 0.12 U 0.058 J G 0.13 G 0.16 U G 0.60 ULAI09 1330 Ulster St 1/20/2010 1st Floor 0.33 < 0.063 < 0.041 U< 0.064 U < 0.065 U< 0.13 U < 0.052 J < 0.31 < 0.18 U < 0.64 U <LAI10 1330 Ulster St 1/20/2010 Crawl Space 0.27 J 0.089 0.053 U 0.082 U 0.083 U 0.16 U 0.048 J 0.13 0.22 U 0.82 ULAI11 1330 Ulster St 1/20/2010 Basement 0.26 J 0.096 0.051 U 0.08 U 0.081 U 0.16 U 0.047 J 0.2 0.22 U 0.80 ULAI12 1305 Uinta St 1/21/2010 1st Floor 0.33 0.082 0.048 U 0.074 U 0.076 U 0.15 U 0.2052 J 0.15 0.20 U 0.74 U

LAI12 Lab Dup 1305 Uinta St 1/21/2010 1st Floor 0.34 0.082 0.048 U 0.074 U 0.076 U 0.15 U 0.051 J 0.15 0.20 U 0.74 ULAI13 1305 Uinta St 1/21/2010 Basement 0.3 0.064 0.05 U 0.078 U 0.079 U 0.16 U 0.05 J 0.13 0.21 U 0.78 ULAI14 1235 Valentia St 1/21/2010 1st Floor 0.28 J 0.086 0.057 U 0.088 U 0.09 U 0.18 U 0.048 J 0.68 0.24 U 0.88 ULAI15 1235 Valentia St 1/21/2010 Basement 0.26 0.081 0.05 U 0.078 U 0.079 U 0.16 U 0.045 J 0.28 0.21 U 0.78 ULAI16 1222 Uinta St 1/22/2010 1st Floor 0.33 J 0.15 0.073 U 0.11 U 0.12 U 0.22 U 0.051 J 0.22 0.31 U 1.1 ULAI17 1222 Uinta St 1/22/2010 Basement 0.32 G 0.19 G 0.0084 J G 0.067 U G 0.012 J G 0.13 UG 0.054 J G 0.18 G 0.18 U G 0.67 U G

LAI17DUP 1222 Uinta St 1/22/2010 Basement 0.36 J 0.22 0.13 U 0.20 U 0.20 U 0.40 U 0.06 J 0.32 0.55 U 2.0 ULAI18 1353 Uinta St 1/22/2010 1st Floor 1.5 0.096 0.053 U 0.082 U 0.083 U 0.16 U 0.063 J 0.12 0.22 U 0.82 U

LAI18 Lab Dup 1353 Uinta St 1/22/2010 1st Floor 1.5 0.094 0.053 U 0.082 U 0.083 U 0.16 U 0.061 J 0.085 0.22 U 0.82 ULAI19 1353 Uinta St 1/22/2010 Basement 6.6 0.14 0.059 U 0.091 U 0.093 U 0.18 U 0.053 J 0.086 J 0.25 U 0.91 ULAI20 1353 Uinta St 1/22/2010 Crawl Space 0.91 0.094 0.055 U 0.086 U 0.088 U 0.17 U 0.05 J 0.098 0.24 U 0.86 ULAI21 1350 Ulster St 1/27/2010 Basement 0.34 0.06 0.053 U 0.082 U 0.083 U 0.16 U 0.048 J 0.34 0.22 U 0.82 U

LAI21DUP 1350 Ulster St 1/27/2010 Basement 0.42 0.068 0.048 U 0.074 U 0.076 U 0.15 U 0.047 J 0.34 0.2 U 0.74 ULAI22 1350 Ulster St 1/27/2010 1st Floor 0.34 0.053 0.051 U 0.08 U 0.081 U 0.16 U 0.05 J 0.47 0.22 U 0.8 U

Outdoor AirLAA01 1235 Uinta St 1/15/2010 0.36 < 0.089 < 0.04 U 0.061 U 0.063 U 0.12 U 0.049 J 0.11 0.17 U 0.61 ULAA02 1282 Uinta St 1/19/2010 0.49 0.056 0.053 U 0.082 U 0.083 U 0.16 U 0.047 J 0.13 0.22 U 0.82 ULAA03 1238 Uinta St 1/20/2010 0.23 J 0.038 J 0.062 U 0.097 U 0.099 U 0.19 U 0.044 J 0.092 J 0.27 U 0.97 ULAA04 1305 Uinta St 1/21/2010 0.27 0.029 J 0.047 U 0.072 U 0.074 U 0.14 U 0.042 J 0.11 0.2 U 0.72 ULAA05 1222 Uinta St 1/22/2010 0.32 0.046 0.042 U 0.065 U 0.066 U 0.13 U 0.048 J 0.11 0.18 U 0.65 U

"U" Not detected above the MDL. RL value provided in concentration column"J" Estimated value between the MDL and RL"G" Final lab vacuum lower than final field vacuum - canister may have leaked during shipment"<" Final field vacuum equal to zero - sample duration may be less than 24 hours

1, 1, 2-TCA (ug/m3)

trans-1, 2-DCE (ug/m3)1, 1-DCA (ug/m3)

cis-1, 2-DCE (ug/m3)PCE (ug/m3) TCE (ug/m3)

Vinyl Chloride (ug/m3) 1, 1-DCE (ug/m3)

1, 1, 1-TCA (ug/m3) 1, 2-DCA (ug/m3)

Page 45: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 6. Sub-Slab Results for January February 2010

Page 1 of 1

Sample ID Sample LocationSample

Date

LAS01 1235 Uinta St 1/15/2010 5.6 J 30 3.7 U 5.7 U 5.8 U 5.7 U 7.9 U 5.8 U 7.9 U 5.7 ULAS01 Lab Dup 1235 Uinta St 1/15/2010 5.5 J 29 3.7 U 5.7 U 5.8 U 5.7 U 7.9 U 5.8 U 7.9 U 5.7 U

LAS01DUP 1235 Uinta St 1/15/2010 6.4 J 26 4.4 U 6.8 U 7.0 U 6.8 U 9.4 U 7.0 U 9.4 U 6.8 ULAS02 1282 Uinta St 1/19/2010 1.34 U ID 1.47 U ID 4.8 U 7.5 U 7.7 U 7.5 U 10 U 7.7 U 10 U 7.5 ULAS10 1282 Uinta St 2/23/2010 17 200 3.9 U 6.1 U 6.2 U 6.1 U 8.3 U 6.2 U 8.3 U 6.1 ULAS11 1282 Uinta St 2/23/2010 24 250 4.0 U 6.2 U 6.3 U 6.2 U 8.5 U 6.3 U 8.5 U 6.2 ULAS03 1238 Uinta St 1/20/2010 18 ID 260 ID 4.3 U 6.7 U 6.8 U 6.7 U 9.2 U 6.8 U 9.2 U 6.7 ULAS04 1330 Ulster St 1/20/2010 3.9 J ID 34 ID 4.7 U 7.3 U 7.4 U 7.3 U 10 U 7.4 U 10 U 7.3 ULAS05 1305 Uinta St 1/21/2010 4.2 J 28 4.2 U 6.5 U 6.6 U 6.5 U 8.9 U 6.6 U 8.9 U 6.5 ULAS06 1235 Valentia St 1/21/2010 7.6 J 88 4.1 U 6.3 U 6.4 U 6.3 U 8.7 U 6.4 U 8.7 U 6.3 U

LAS06 Lab Dup 1235 Valentia St 1/21/2010 8.2 J 89 4.1 U 6.3 U 6.4 U 6.3 U 8.7 U 6.4 U 8.7 U 6.3 ULAS06DUP 1235 Valentia St 1/21/2010 8.3 J 80 4.1 U 6.3 U 6.4 U 6.3 U 8.7 U 6.4 U 8.7 U 6.3 U

LAS07 1222 Uinta St 1/22/2010 14 48 4.1 U 6.3 U 6.4 U 6.3 U 8.7 U 6.4 U 8.7 U 6.3 ULAS07DUP 1222 Uinta St 1/22/2010 5.3 J 48 4.1 U 6.3 U 6.4 U 6.3 U 8.7 U 6.4 U 8.7 U 6.3 U

LAS08 1353 Uinta St 1/22/2010 1.8 J 14 4.1 U 6.3 U 6.4 U 6.3 U 8.7 U 6.4 U 8.7 U 6.3 ULAS09 1350 Ulster St 1/27/2010 1.07 U 1.17 U 3.9 U 6.0 U 6.1 U 6.0 U 8.3 U 6.1 U 8.3 U 6.0 U

LAS09DUP 1350 Ulster St 1/27/2010 1.02 U 1.12 U 3.7 U 5.7 U 5.8 U 5.7 U 7.9 U 5.8 U 7.9 U 5.7 U

"U" Not detected above the MDL indicated for TCE and PCE. RL value provided in concentration column for remaining compounds"J" Estimated value between the MDL and RL"ID" No duplicate collected on this date

TCE (ug/m3)PCE (ug/m3)cis-1, 2-DCE

(ug/m3)1, 1-DCA (ug/m3)

trans-1, 2-DCE (ug/m3)

1, 1, 2-TCA (ug/m3)

1, 2-DCA (ug/m3)

1, 1, 1-TCA (ug/m3)

1, 1-DCE (ug/m3)

Vinyl Chloride (ug/m3)

Page 46: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 7. Soil Vapor Results for January 2010

Page 1 of 1

Sample ID Sample Date

EG-SGCA06 1/21/2010 120 1200 3.5 U V 3.8 J 5.5 U 5.4 U 4.4 J 5.5 U 7.4 U 5.4 UEG-SGCA07R 1/20/2010 34 380 3.5 U V 5.5 U 5.6 U 5.5 U 7.5 U 5.6 U 7.5 U 5.5 UEG-SGCA08R 1/20/2010 9.5 U 7.6 U 3.6 U V 5.6 U 5.7 U 5.6 U 7.7 U 5.7 U 7.7 U 5.6 UEG-SGCA09 1/20/2010 2.9 J 25 3.5 U V 5.5 U 5.6 U 5.5 U 7.5 U 5.6 U 7.5 U 5.5 UEG-SGCA10 1/20/2010 3.2 J 26 3.5 U V 5.4 U 5.5 U 5.4 U 7.4 U 5.5 U 7.4 U 5.4 U

EG-SGCA10 Lab Dup 1/20/2010 3 J 26 3.5 U V 5.4 U 5.5 U 5.4 U 7.4 U 5.5 U 7.4 U 5.4 UEG-SGCA11 1/21/2010 12 G 46 G 2.8 U V 4.4 U 4.4 U 4.4 U 6.0 U 0.71 JG 6.0 U 4.4 UEG-SGCA12 1/21/2010 13 30 3.7 U V 5.8 U 5.9 U 5.8 U 7.9 U 5.9 U 7.9 U 5.8 UEG-SGCA13 1/21/2010 3.7 J 27 3.4 U V 5.2 U 5.3 U 5.2 U 7.2 U 5.3 U 7.2 U 5.2 U

EG-SGCA13DUP 1/21/2010 2.3 J 18 3.4 U V 5.2 U 5.3 U 5.2 U 7.2 U 5.3 U 7.2 U 5.2 UEG-SGCA14 1/21/2010 25 g 190 g 3.6 U V 5.5 U 5.6 U 5.5 U 7.6 U 5.6 U 7.6 U 5.5 UEG-SGCA15 1/21/2010 14 87 3.9 U V 6.0 U 6.1 U 6.0 U 8.3 U 6.1 U 8.3 U 6.0 UEG-SGCA16 1/21/2010 29 G 280 G 2.9 U V 3.1 JG 4.6 U 2.2 JG 2.2 JG 4.6 U 6.3 U 4.6 UEG-SGCA17 1/21/2010 65 410 3.4 U V 5.3 U 5.4 U 5.3 U 3.1 J 5.4 U 7.2 U 5.3 UEG-SGCA18 1/20/2010 67 560 3.4 U V 6.7 5.3 U 5.2 U 7.2 U 5.3 U 7.2 U 5.2 U

EG-SGCA18DUP 1/20/2010 40 340 3.5 U V 4.3 J 5.5 U 5.4 U 2.0 J 5.5 U 7.4 U 5.4 UEG-SGCA18DUP Lab Dup 1/20/2010 44 390 3.5 U V 2.8 J 5.5 U 5.4 U 2.0 J 5.5 U 7.4 U 5.4 U

EG-SGCA19 1/20/2010 1.9 J 6.4 J 3.4 U V 5.3 U 5.4 U 5.3 U 7.2 U 5.4 U 7.2 U 5.3 UEG-SGCA20 1/20/2010 4.8 J 4.7 J 3.4 U V 5.2 U 5.3 U 5.2 U 7.2 U 5.3 U 7.2 U 5.2 U

"U" Not detected above the MDL. RL value provided in concentration column"J" Estimated value between the MDL and RL"G" Final lab vacuum lower than final field vacuum - canister may have leaked during shipment"g" Low intial field vacuum"V" Laboratory calibration deviation above 25% for vinyl chloride

trans-1, 2-DCE (ug/m3)PCE (ug/m3) TCE (ug/m3)

Vinyl Chloride (ug/m3)

1, 1, 2-TCA (ug/m3)

1, 2-DCA (ug/m3)

1, 1, 1-TCA (ug/m3)

cis-1, 2-DCE (ug/m3)

1, 1-DCA (ug/m3)

1, 1-DCE (ug/m3)

Page 47: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 8 OU# 5 Study Area Groundwater Analytical Results (ug/L)January 2010

Sample No. Screened Interval Date

IM-12D bedrock 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 39 <2 U <2 UMW0B04D bedrock 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 51 <2 U <2 UIM-7D bedrock 1/20/2010 <2 U <2 U <2 U <2 U 4.8 <2 U <2 U 130 <2 U 3.7MW0B21 alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 11 <2 U <2 UB-1 alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 32 <2 U <2 UIM-10 alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 2 U <2 U <2 UIM-11 alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 5.9 <2 U <2 UIM-7A alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 9.8 <2 U <2 UMW0B04 alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 11 <2 U <2 UDup 7 (MWOB04) alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 11 <2 U <2 UMW0B22R alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 14 <2 U <2 UMWCA12 alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 11 <2 U <2 UMWCM14* alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 5.7 <2 U <2 UMWCM15* alluvial 1/20/2010 <2 U <2 U <2 U <2 U <2 U <2 U <2 U 7 <2 U <2 U

average alluvial 10.95Detected concentrations are bolded.Dup - duplicate sampleFlag - laboratory data qualifierU - compound was not detected, reported value is the laboratory reporting limitJ - compound was detected at a concentration between the method detection limit and the laboratory reporting limit. The reported concentration is estimated.D - sample was diluted for quantitation*MWCM15 is the replacement well for MWCA13*MWCM14 is the replacement well for IM-9

Vinyl Chloride PCE1,1,2-TCATCE

Cis-1,2,-DCE1,1-DCA

Trans-1,2,-DCE 1,2-DCA1,1,1-TCA1,1-DCE

Page 48: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 9. Sub-slab Vapor to Indoor Air TCE Attenuation Factors

1998 Indoor Air/Sub‐Slab  

2001 Indoor Air/Sub‐Slab 

Sample Location

Indoor Air TCE Concentration (ug/m3) Sub‐Slab TCE Concentration (ug/m3)2010Air/S

 Indoor ub‐Slab 

Ratio

2A007 Indoor ir/Sub‐SlabRatio 2010 2007 2001 1998  2010 2007 2001 1998 RatioRatio

1222 Uinta St 0.22 0.35 0.58 ‐ 48 160 111 ‐ 0.0046 0.0022 0.00521235 Uinta St 0.33 9.7 43 0.9# 30 1100 3,145 12,016 0.011 0.0088 0.0137 0.0001

1235 Valentia St 0.086 ‐ ‐ 0.26 89 ‐ ‐ 1.62 0.0010 ‐1238 Uinta St 1.7 5.6 6.6 ‐ 260 480 808 ‐ 0.0065 0.012 0.00821271 Uinta St ‐ 0.98 0.81 ‐ ‐ 940 119 ‐ ‐ 0.0010 0.00681282 Uinta St 1.1 5.1 5.7 ‐ 250 1400 2,380 ‐ 0.0044 0.0036 0.00241305 Uinta St 0.082 0.11 ‐ 1.6 28 ‐ ‐ 1340 0.0029 ‐ 0.00121314 Ulster St* ‐ 0.53* ‐ 0.34 <0.98 ‐ 201 ‐ NA 0.00171329 Uinta St ‐ 0.67 ‐ 0.23# ‐ 200 ‐ 502 ‐ 0.0034 0.00051330 Ulster St 0.096 ‐ ‐ 0.27 34 ‐ ‐ 79 0.0028 ‐ 0.00341350 Ulster St 0.068 0.16 ‐ 0.7 <1.17 14 ‐ <1.03 NA 0.011 NA1353 Uinta St 0.14 ‐ ‐ 0.38 14 ‐ ‐ 208 0.010 ‐ 0.0018

Average 0.0054 0.0060 0.0073 0.0020Median 0.0045 0.0036 0.0068 0.0014

ug/m3  micrograms per cubic meterNote: Blank cell indicates sample was not analyzed in that sampling event*Subslab system operating in 2007# anomalous result suspected of low bias due to open house conditions

Page 49: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 10 Soil Gas to Indoor Air Attenuation Factors

Closest Soil Gas Point

Soil Gas TCE 2010

Soil Gas TCE 2007

Soil Gas TCE 1998

SG/IA AF 2010

SG/IA AF 2007

SG/IA AF 1998

2010 2007 1998 ug/m3 ug/m3 ug/m31222 Uinta St 0.22 0.35 - SGCA17&19 208 653 1393 1.06E-03 5.36E-04

1235 Uinta St 0.33 9.7 0.9# SGCA16 280 1500 4391 1.18E-03 6.47E-03 NA1235 Valentia St 0.086 - 0.26 SGCA20 4.7 7.6 74 1.83E-02 3.51E-03

1238 Uinta St 1.7 5.6 - SGCA16 280 1500 4391 6.07E-03 3.73E-031271 Uinta St - 0.98 - SGCA15 87 220 4.45E-031282 Uinta St 1.1 5.1 - SGCA14 190 530 15# 5.79E-03 9.62E-031305 Uinta St 0.082 0.11 1.6 SGCA13 27 120 3.04E-03 9.17E-04

1329 Uinta St - 0.67 0.23# SGCA12 30 470 1895 1.43E-03 NA1330 Ulster St 0.096 - 0.27 SGCA09 25 110 388 3.84E-03 6.96E-041350 Ulster St 0.068 0.16 0.7 SGCA10 26 150 2.62E-03 1.07E-031353 Uinta St 0.14 - 0.38 SGCA10 26 150 5.38E-03

Average 0.42 2.83 0.64 108 492 2089 3.62E-03 3.53E-03 2.10E-03Median 0.14 0.83 0.38 30 220 1644 3.84E-03 2.58E-03 2.10E-03

Note: Blank cell indicates sample was not analyzed in that sampling event

1235 Valentia result from 2010 is strongly influenced by background indoor air and excluded from average attenuation factor

Sample Location

Indoor Air TCE Concentration

(ug/m3)

# Anomalously low value suspected of low bias. Excluded from attenuation factors

Page 50: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 11 Groundwater to Soil Gas Attenuation Factors

Closest Soil Gas Point

Soil Gas TCE 2010

Soil Gas TCE 2007

Soil Gas TCE 1998

Closest GW well GW 2010 GW 2007 GW 1998

GW/SG AF 2010

GW/SG AF 2007

GW/SG AF 1998

ug/m3 ug/m3 ug/m3 ug/L ug/L ug/L1222 Uinta St SGCA17&19 208 653 1393 IM-7A 9.8 31 9.56E-02 9.49E-021235 Uinta St SGCA16 280 1500 4391 IM-7A 9.8 31 1.29E-01 2.18E-01

1235 Valentia St SGCA20 4.7 7.6 74 MWOB22 14 8.1 15 1.51E-03 4.23E-03 2.22E-021238 Uinta St SGCA16 280 1500 4391 MWOB21 11 46 140 1.15E-01 1.47E-01 1.41E-011271 Uinta St SGCA15 87 220 IM-10 26 3.81E-02

1282 Uinta St SGCA14 190 530 15# IM-11 5.9 23 1.45E-01 1.04E-011305 Uinta St SGCA13 27 120 IM-11 5.9 23 2.06E-02 2.35E-021329 Uinta St SGCA12 30 470 18951330 Ulster St SGCA09 25 110 388 MWCA12 11 21 1.02E-02 2.36E-021350 Ulster St SGCA10 26 150 MWCA12 11 21 1.06E-02 3.22E-021353 Uinta St SGCA10 26 150 MWOB04 11 41 110 1.06E-02 1.65E-02

Average 108 492 2089 10 27 88 5.97E-02 7.02E-02 8.18E-02Median 30 220 1644 11 24.5 110 2.06E-02 3.51E-02 8.18E-02

Note: Blank cell indicates sample was not analyzed in that sampling event

Sample Location

# Anomalous value, suspected of low bias. Excluded from attenuation factor calculations

Page 51: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 12 Groundwater to Indoor Air Attenuation Factors

Closest GW well GW 2010 GW 2007 GW 2001 GW 1998

GW/IA AF 2010

GW/IA AF 2007

GW/IA AF 2001

GW/IA AF 1998

2010 2007 2001 1998 ug/L ug/L ug/L ug/L1222 Uinta St 0.22 0.35 0.58 - IM-7A 9.8 31 1.01E-04 5.09E-05

1235 Uinta St 0.33 9.7 43 0.9# IM-7A 9.8 31 1.52E-04 1.41E-031235 Valentia St 0.086 - - 0.26 MWOB22 14 8.1 15 2.77E-05 7.81E-05

1238 Uinta St 1.7 5.6 6.6 - MWOB21 11 46 140 140 6.96E-04 5.48E-04 2.12E-041271 Uinta St - 0.98 0.81 - IM-10 26 1.70E-041282 Uinta St 1.1 5.1 5.7 - IM-11 5.9 23 8.40E-04 9.99E-041305 Uinta St 0.082 0.11 - 1.6 IM-11 5.9 23 6.26E-05 2.15E-05

1329 Uinta St - 0.67 - 0.23#

1330 Ulster St 0.096 - - 0.27 MWCA12 11 21 3.93E-051350 Ulster St 0.068 0.16 - 0.7 MWCA12 11 21 2.78E-05 3.43E-051353 Uinta St 0.14 - - 0.38 MWOB04 11 41 110 5.73E-05 1.56E-05

Average 10 27 140 88 2.23E-04 4.62E-04 2.12E-04 4.68E-05Median 11 25 140 110 6.26E-05 1.70E-04 2.12E-04 4.68E-05

Note: Blank cell indicates sample was not analyzed in that sampling event

Sample LocationIndoor Air TCE Concentration (ug/m3)

# Anomalously low value suspected of low bias

Page 52: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 13 Historical OU#5 Groundwater TCE Concentrations and Percent Reduction vs. Time

2010(ug

TCE /L) Mar-07 2004/2005 2001 1999-2000 1996-98

PercDecre

2007 to

ent ase 2010 20

Percent Decrease 01 to 2010

Percent Decrease 1999-2000

to 2010

Percent Decrease 1996-98 to

2010

Percent Decrease 1996-98 to

2007BEDROCK WELLSIM-12D 39 90 72 56.67%MWOB04D 51 120 130 150 165 150 57.50% 66.00% 69.09%IM-7D 130 270 300 51.85%

ALLUVIAL WELLSMWOB21 11 46 42 140 170 140 76.09% 92.14% 93.53% 92.14% 67.14%B-1 32 24 82 -33.33%IM-10 <2 26 11 >92%IM-11 5.9 23 6.6 74.35%IM-7A 9.8 31 68.39%MWOB04 11 41 27 98 110 73.17% 88.78% 90.00% 62.73%MWOB22R 14 8.1 11 15 -72.84% -27.27% 6.67% 46.00%MWCA12 11 21 47.62%MWCM14* 5.7 3.3 -72.73%MWCM15* 7 27 74.07%

Median Alluvial 11 25 27 140 98 110 68.39% 92.14% 88.78% 90.00% 62.73%

*MWCM15 is the replacement well for MWCA13*MWCM14 is the replacement well for IM-9

Page 53: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 14. Historical Soil Vapor TCE Concentrations and Percent Reduction

Page 1 of 1

2010 2007 1998

% Decrease 1998 to

2010

% Decrease 2007 to

2010

% Decrease 1998 to

2007

EG-SGCA06 SGOB27 1200 3100 203# NA 61.3% NAEG-SGCA07R 380EG-SGCA08R <7.6 <5200EG-SGCA09 SGOB37 25 110 388 93.6% 77.3% 71.6%EG-SGCA10 26 150 82.7%EG-SGCA11 SGOB16 46 400 739 93.8% 88.5% 45.9%EG-SGCA12 SGOB38 30 470 1895 98.4% 93.6% 75.2%EG-SGCA13 27 120 77.5%

EG-SGCA14 SGOB32 190 530 15# NA 64.2% NAEG-SGCA15 87 220 60.5%EG-SGCA16 SGOB21 280 1500 4391 93.6% 81.3% 65.8%EG-SGCA17 SGOB09 410 1300 2778 85.2% 68.5% 53.2%EG-SGCA18 560 2600 78.5%EG-SGCA19 SGOB28 6.4 5.8 8 20.0% -10.3% 27.5%EG-SGCA20 SGOB22 4.7 7.6 74 93.6% 38.2% 89.7%

Average 234 809 1468 82.6% 66.3% 61.3%Median 66.5 400 739 93.6% 77.3% 65.8%

ug/m3 micrograms per cubic meter"J" Estimated value between the MDL and RL# indicates anomalous value, suspected of low bias

Sample Location

TCE Concentration(ug/m3)

Equivalent 1998 Location

Page 54: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 15. Historical Sub-Slab TCE Concentrations and Percent Reduction

Page 1 of 1

% Decrease 1998 to

2010

% Decrease 2001 to

2010

% Decrease 2007 to

2010

% Decrease 1998 to

2007

% Decrease 2001 to

2007 2010 2007 2001 1998

1222 Uinta St 48 160 111 56.8% 70.0% -44.1%1235 Uinta St 30 1100 3,145 12,016 anom anom anom 90.8% 65.0%

1235 Valentia St 89 1.62 -5393.8%1238 Uinta St 260 480 808 67.8% 45.8% 40.6%

1271 Uinta St 940 119# NA1282 Uinta St 250 1400 2,380 89.5% 82.1% 41.2%1305 Uinta St 28 1340 97.9%

1314 Ulster St* <0.98* 201 NA1329 Uinta St 200 502 60.2%1330 Ulster St 34 79 57.0%1350 Ulster St <1.17 14 (6.4) <1.03 NA NA NA1353 Uinta St 14 208 93.3%

Average 94 713 1611 2050 -1286.4% 71.4% 66.0% 75.5% 25.7%Median 41 710 1594 208 75.1% 67.8% 70.0% 75.5% 40.9%

ug/m3 micrograms per cubic meterNote: Blank cell indicates sample was not analyzed in that event*Subslab system operating in 2007

February 2001 sub-slab results utilized

Sample Location

TCE Concentration (ug/m3)

# Anomalous result excluded from calculations (Note other results up to 2100 ug/m3 during this event)

Page 55: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Table 16. Historical Indoor Air TCE Results and Percent Reduction

Page 1 of 1

Jan. 2010 March 2007 February 2001 Aug.-Sept. 1998

% Decrease 1998 to

2010

% Decrease 2001 to

2010

% Decrease 2007 to

2010

% Decrease 1998 to

2007

% Decrease 2001 to

2007

1222 Uinta St 1st Floor 0.15 0.18 0.58 74.1% 69.0%(UA21) Basement 0.22 0.35 37.1%

Outside 0.0461235 Uinta St 1st Floor 0.22 8.2 Anomalous

(UA03) Basement 0.33 9.7 43 0.9# NA Anomalous Anomalous NA 77.4%Outside 0.089 0.097

1235 Valentia St 1st Floor 0.086(VA06) Basement 0.081 0.26 NA

1238 Uinta St 1st Floor 1.7 3.7(UA22) Basement 1.6 5.6 6.6 75.8% 71.4% 15.2%

Outside 0.0561271 Uinta St 1st Floor 0.51 0.81 37.0%

(UA18) Basement 0.981282 Uinta St 1st Floor 1.1 4.4 5.7 80.7% 22.8%

(UA24) Crawl Space 1.2Basement 0.89 5.1 82.5%Outside 0.038

1305 Uinta St 1st Floor 0.082 0.11(UA07) Basement 0.064 0.096 1.6 96.0% 33.3% 94.0%

Outside 0.0291314 Ulster St* 1st Floor 0.53*

(UL10) Basement 0.51* 0.34 NA1329 Uinta St 1st Floor 0.45

(UI14) Basement 0.67 0.23#

Outside 0.0251330 Ulster St 1st Floor 0.063

(UL12) Crawl Space 0.089Basement 0.096 0.27 64.4%

1350 Ulster St 1st Floor 0.053 0.16(UL15) Basement 0.068 0.12 0.7 NA 43.3% NA

Outside 0.0211353 Uinta St 1st Floor 0.096

(UI13) Crawl Space 0.094Basement 0.14 0.38 63.2%

Average 0.334 2.130 11.338 0.592 74.5% 76.9% 53.6% 94.0% 44.3%Median 0.092 0.450 5.700 0.360 64.4% 75.8% 43.3% 94.0% 37.0%

Note: Blank cell indicates sample was not analyzed in that event(UA21) Sample location identifier in previous reports* Operating sub-slab ventilation system installed 8/23/03# anomalous result suspected of low bias due to open house conditions1998 results for 1235 Valentia and 1350 Ulster are considered to represent background levels for those homes at that time

Sample Location Sample Level

TCE Concentration (ug/m3) % Decrease in TCE Concentration

Page 56: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

FIGURES

Page 57: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater
Page 58: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater
Page 59: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater
Page 60: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater
Page 61: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater
Page 62: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

R² = 0.6569

R² = 0.8753

R² = 0.414

0

20

40

60

80

100

120

140

160

180

1/1/1996 9/27/1998 6/23/2001 3/19/2004 12/14/2006 9/9/2009 6/5/2012

TCE

(ug/

L)

Sample Date

Figure 6 Alluvial Groundwater TCE Results vs. Time

Former Lowry A.F.B. OU#5

MWOB04

MWOB21

MWOB22

MWCA12

MWCM14

MWCM15

IM-7A

IM-10

IM-11

B-1

Expon. (MWOB04)

Expon. (MWOB21)

Expon. (B-1)

Well ID

Page 63: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

1996 1998 2000 2002 2004 2006 2008 2010 2012

TCE

(ug/

m3)

Sample Date

Figure 7 Soil Gas TCE Results vs. Time

Former Lowry A.F.B. OU#5

SGCA09

SGCA11

SGCA12

SGCA14

SGCA16

SGCA17

SGCA19

SGCA20

SGCA10

SGCA18

SGCA13

SGCA15

Page 64: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

10

100

1,000

10,000

100,000

1996 1998 2000 2002 2004 2006 2008 2010 2012

TCE

(ug/

m3)

Sample Date

Figure 8 Sub-Slab TCE Results vs. Time

Former Lowry A.F.B. OU#5

1235 Uinta St.

1222 Uinta St.

1238 Uinta St.

1282 Uinta St.

1305 Uinta St.

1329 Uinta St.

1271 Uinta St.

1330 Ulster St.

1353 Ulster St.

Page 65: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Figure 9 Average Percent Reduction in TCE Concentration by Media: 1998-2010

0

10

20

30

40

50

60

70

80

90

100

Groundwater Soil Gas Sub-Slab Vapor Indoor Air

Page 66: Indoor Air Study Data Summary and Analysis Report€¦ · As part of the remediation, a program to sample residential indoor air, outdoor air, sub-slab vapor, soil vapor, and groundwater

Figure 10Indoor Air Results and Groundwater Results

R2 = 0.9036

R2 = 0.9552

R2 = 1

0

10

20

30

40

50

60

70

80

90

100

Indoor Air Study Date

TCE

Con

cent

ratio

n, In

door

Air

(ug/

m3)

0

20

40

60

80

100

120

140

160

TCE

Con

cent

ratio

n, G

roun

dwat

er (u

g/L)

Indoor Air, 2001

Indoor Air 2007

Indoor Air, 2010

IA MAX

IA Avg

CDPHE Action Level, 0.8 ug/m3

Groundwater, Average TCE (ug/L)

Expon. (IA Avg)

Expon. (IA MAX)

Expon. (Groundwater, AverageTCE (ug/L) )

Groundwater - Average TCE Concentration

Indoor Air, Maximum

Indoor Air,Average

200

1

2007

2010