CDB Goldair PO Box 100-707, North Shore Mail Centre, Auckland www.orbitlighting.co.nz GUIDE TO Downlights In July 2012 new regulations were introduced to ensure safer installation of down lights with insulation. Down lights must be clearly marked regarding this (refer table Pg2). Note: Recessed lights without these marking do not comply with the new regulations. Markings: • CA - Insulation abutted but not covering the down light. • IC – Insulation can abut and cover the down light. • The transformer in all cases is recommended to be above insulation and as far away from fitting as possible. summary of the range Choosing the level of light required in your room There are a number of considerations when determining the appropriate level of light (total lumens) for any room. Including: • Area (m 2 ) • Ceiling height • Room colours ( light / dark) - see tips & tricks Some general rules that can be used to assist with choosing the correct downlight and number required per room are: • Try to achieve minimum Lumens per square metre for Entry & Hall - 140 Lumens /m 2 Bedrooms & Living Areas - 200 Lumens /m 2 Kitchens & Bathroom - 300 Lumens /m 2 • Kitchens will require additional planning to minimise shadowing • Space the downlights evenly around the room Try to keep downlights no more than 1.2m – 1.5m apart. Between 0.5m – 0.7m from the wall • For General lighting select the widest beam angle available downlight selection guide

Transcript of In July 2012 new regulations were introduced to … Goldair PO Box 100-707, North Shore Mail Centre,...

CDB Goldair PO Box 100-707, North Shore Mail Centre, Auckland www.orbitlighting.co.nz

Guide to

Downlights

In July 2012 new regulations were introduced to ensure safer installation of down lights with insulation. Down lights must be clearly marked regarding this (refer table Pg2).

Note: Recessed lights without these marking do not comply with the new regulations.

Markings:

• CA - Insulation abutted but not covering the down light.

• IC– Insulation can abut and cover the down light.

• Thetransformer in all cases is recommended to be above insulation and as far away from fitting as possible.

summary of the range

Choosingtheleveloflightrequiredin

yourroom

There are a number of considerations when determining the appropriate level of light (total lumens) for any room. Including:

• Area (m2)

• Ceiling height

• Room colours ( light / dark) - see tips & tricks

Somegeneralrulesthatcanbeusedto

assistwithchoosingthecorrectdownlightand

numberrequiredperroomare:

• Try to achieve minimum Lumens per square metre for

• Entry & Hall - 140 Lumens /m2

• Bedrooms & Living Areas - 200 Lumens /m2

• Kitchens & Bathroom - 300 Lumens /m2

• Kitchens will require additional planning to minimise shadowing

• Space the downlights evenly around the room

• Try to keep downlights no more than 1.2m – 1.5m apart.

• Between 0.5m – 0.7m from the wall

• For General lighting select the widest beam angle available

downlight selection guide

downlighttypes

suitableforinsulation

Productspecs

Applications

Optionalupgrades

N/A

R80ODLFR80A / 80T

White and Satin Nickel finishes

Can be repainted to match décor

Suitable for use with E27 base R80, GLS, CFL & LED lamps to a maximum 100w

Lamp NOT included

Note: For Additional Details Refer Summary Table Page 10

** Minimum insulation clearance (MiC) – from insulation to building element above

** Minimum side clearance to building element (SCB)

** Minimum clearance to building element (HCB) – from top of luminaire to building element above

CLASS DESCRIPTION RESIDENTAL COMMERCIAL

Closed recessed luminaire that allows building insulation (as specified by the downlight manufacturer) to come into contact with it’s sides. insulation material can safely be continually exposed to temperatures up to 150°C.

Closed recessed luminaire that allows building insulation (as specified by the downlight manufacturer) to come into contact with it’s sides. insulation material can safely be continually exposed to temperatures up to 90°C.

Closed recessed luminaire that allows building insulation (as specified by the downlight manufacturer) to abut and cover it. insulation material can safely be continually exposed to temperatures up to 90°C.

Closed recessed luminaire that allows building insulation to abut and cover it. insulation material can safely be continually exposed to temperatures up to 90°C.

Recessed luminaire where building insulation material must not cover or come into contact with any part of the luminaire.

MinimumClearancesforRecessedLuminaires

Recessed luminaries may pose a risk of fire or damage to property if not installed and maintained correctly.

The Down light location to insulation and building materials must be in accordance with the Manufacturers instructions.

NO

80°C

ABUTED & COVERED

ABUTED & COVERED

downlighttypes

N/A

Gu10

CODES Round Round4pack

White ODLFG35W ODLF4G35W

Satin Nickel ODLFG35SN ODLF4G35SN

Lumens 290 290

suitableforinsulation

Productspecs

Applications

Optionalupgrades

Mains Voltage 35w Eco Down light

Includes 35w GU10 lamp

Round fascia

White and Satin Nickel Finish

No transformer required

Input 240V 50Hz

Note: For Additional Details Refer Summary Table Page 10

suitableforinsulation

Productspecs

Applications

Optionalupgrades

Note: For Additional Details Refer Summary Table Page 10

MR16Low Voltage 35w Eco Down light

Includes 35w IR high efficiency lamp

Round or square fascia options

White and Satin Nickel Finish

12volt transformer included

Input 240V 50Hz

CODES Round Square Round4pack

White ODLFM35W OSDLFM35W ODLF4M35W

Satin Nickel ODLFM35SN OSDLFM35SN ODLF4M35SN

Lumen 400 400 400

Brushed Aluminium or White fascia

Round only

Available in 3w, 5w & 7w

Warm white (3000k)

LED driver included

Input 240V 50Hz

downlighttypes

Ledintegrated

White ODLI3W2 ODLI5W2 ODLI7W2

Brushed Aluminium ODLI3B2 ODLI5B2 ODLI7B2

Lumens 240 350 490

3watt45degreebeamangle

5watt45degreebeamangle

7watt60degreebeamangleCODES

ABUTED & COVERED

suitableforinsulation

Productspecs

Applications

Note: For Additional Details Refer Summary Table Page 10

LED

Low HeatLow Heat

Low EnergyLow Energy

Long LifeLong Life

LEDDownlightsare highly efficient and able to deliver substantial energy savings.

LED is capable of replacing both halogen and incandescent down lights when lumen

output and design factors are considered.

Mercury FreeMercury Free

Brushed Aluminium finish

Available in single double and triple format

Warm white (3000k)

LED driver included

Input 240V 50Hz

Brushed Aluminium ODLI31SB2 ODLI32SB2 ODLI33SB2

Lumens 240 460 620

3watt45degreebeamangle

2x3watt45degreebeamangle

3x3watt45degreebeamangleCODES

ABUTED & COVERED

Ledintegrated

suitableforinsulation

Productspecs

Applications

Note: For Additional Details Refer Summary Table Page 10

White finish

Available in 5w, 9w & 12w

Warm white (3000k)

LED driver included

Input 240V 50Hz

downlighttypes

Ledintegrated

Brushed Aluminium ODLI5RW2 ODLI9RW2 ODLI12RW2

Lumens 300 500 600

5watt120degreebeamangle

9watt120degreebeamangle

12watt120degreebeamangleCODES

ABUTED & COVERED

suitableforinsulation

Productspecs

Applications

Note: For Additional Details Refer Summary Table Page 10

what do you need

When choosing the appropriate down light you need to consider:

to know

Howyouwantthelighttoperforminthe

room/spaceitislocated.

It is important to consider the function of the room and the affects you are after.Is the light for:• General Purpose Lighting?

• Accent Lighting?

• Or a combination of these

Areyoulookingforthemostenergy

efficientoption?

LED is by far the most energy efficient option available. However when considering LED you need to consider a few points:• Are you planning to use LED lamps in

a down light fitting or use a dedicated (integrated ) LED down light.

• The spacing and number of down lights required.

• The lumen output required from each fitting

• The beam angle of the LED

Tighter beam angles can be more suited to accent lighting (highlighting an object) rather than ambient lighting (general lighting).

Areyoulookingtoreplaceanyexisting

lightfittings?

If this is the case you may want to try and match the existing size of the hole (refer to cut out guide). Some remedial work may be required to achieve the correct hole size.

ambient lighting

accent lighting

RATINg

iC135

iC

VOLTAgE

240v

12v

TRANSfORMER

Not Required

included

Not included

APPLICATION

Accent

General

Cut out

LAMPbASE

e27

B22

Gu10

MR16

LAMPTyPE

GLS

R80

CFL

Halogen

Led

Lumens

N/A

ABUTED & COVERED

MODEL RATING LAMP INCL

MAX WATTAGE LUMENS BEAM

ANGLECOLOUR

TEMP COLOURS SHAPE SUITABLE LAMPS

TRANSFORMER REQUIRED APPLICATION CUTOUT

(MM)

GU10 CA135 35W 35W 290 38 2700KWhite

Satin NickelRound GU10 35W

240v No Transformer

required

General, Accent & Ambient

86

MR16 CA135 35W 35W 400 38 2700KWhite

Satin NickelRound Square

MR16 35W12v

Transformer included

General, Accent & Ambient

86

R80 CA135 NONE 100W1200 100w R80

N/ALamp

DependantWhite Round

CFL, R80, GLS

240v No Transformer

required

General & Ambient

121

Integrated LED 3W

IC N/A N/A 240 45 3000KWhite

Brushed Aluminium

Roundnon

replaceable

12v LED driver included

Accent 70

Integrated LED 5W

IC N/A N/A 350 45 3000KWhite

Brushed Aluminium

Roundnon

replaceable

12v LED driver included

Accent 95

Integrated LED 7W

IC N/A N/A 490 60 3000KWhite

Brushed Aluminium

Roundnon

replaceable

12v LED driver included

General & Accent

95

Integrated LED SINGLE

IC N/A N/A 240 45 3000KBrushed

Aluminium Square

non replaceable

12v LED driver included

Accent 80x80

Integrated LED DOUBLE

IC N/A N/A 460 45 3000KBrushed

AluminiumSquare

non replaceable

12v LED driver included

General & Accent

160x80

Integrated LED TRIPLE

IC N/A N/A 620 45 3000KBrushed

AluminiumSquare

non replaceable

12v LED driver included

General & Accent

245x80

Integrated LED 5W

IC N/A N/A 300 120 3000K White Roundnon

replaceable

12v LED driver included

General & Accent

95

Integrated LED 9W

IC N/A N/A 500 120 3000K White Roundnon

replaceable

12v LED driver included

General & Accent

121

Integrated LED 12W

IC N/A N/A 600 120 3000K White Roundnon

replaceable

12v LED driver included

General & Accent

121

downlightspecifications

1 10

Howmanydownlights?

Use the formula bellow as a quick guide to determine how many lights you need in your room

Tipandtricks

Higherceilingheight- consider how your fittings will distribute the light. You may place the fittings closer together and use narrow beam fittings over work areas.Darkinteriorcolours - (curtains, walls and carpets etc) will reduce overall light effect. Additional/Higher number of lights will be required.general- To compliment your lighting plan consider using additional light fittings such as table and floor lamps, wall lights.This is a guide only. We recommend for more accurate lighting requirement you consult a lighting specialist.

Room Width (m):

Room Length (m):

Total Room Area (m2):

140 Lumen per m2:

Total Lumen Required:

Lumens per light fitting: (example based on 7W LED)

Min # of lights recommended

example only

3.0m

4.0m

12m2

140

1680

490

3.4

4

your room

x x

x x

= =

= =

÷ ÷

= =