In-Building Coverage · 2019. 7. 26. · INBC-11062014 Bird Technologies® is a recognized leader...
Transcript of In-Building Coverage · 2019. 7. 26. · INBC-11062014 Bird Technologies® is a recognized leader...
30303 Aurora Rd. :: Solon, OH 44139 :: 866.695.4569 :: www.birdrf.com
The Bird® Technologies brands include: Bird Electronic, TX RX Systems, X-COM Systems and DeltaNode.Bird® Technologies reserves the right to modify specifications or discontinue any product without notice.
©2014 Bird TechnologiesINBC-11062014
Bird Technologies® is a recognized leader in various segments of the
RF industry from test equipment to DAS, infrastructure and high speed
data capture and analysis. Each Bird brand specializes in a different area
of RF Expertise. X-COM Systems™, TX RX Systems™, DeltaNode™ and
Bird Electronic® together serve as The RF Experts in cellular, land mobile
adio, broadcast, semiconductor, government, military and medical
markets with one common goal – to provide our customers with the
highest quality, innovative RF products and services all based around
total reliability.
All Bird products can be serviced and calibrated by the Bird Service
Center (BSC). Bird Service Centers and Service Partners are located World
Wide providing a full range of service and support for your Bird Products.
To view the catalog online or download, go to www.birdrf.com
www.birdrf.com
In-Building Coverage
1-866-695-4569 www.birdrf.com 1
In-Building CoverageIn-Building Coverage
For public safety agencies, reliable radio coverage is essential throughout a broad array of public safety jurisdictions, including coverage on the street, in buildings, and in tunnels. The general public often experiences similar needs from the commercial wireless systems they are using. Increasingly, in-building and in-tunnel communications are of key concerns for both public safety agencies and wireless providers since providing reliable coverage in those environments is particularly challenging.
Over the past several years, some jurisdictions have enacted ordinances requiring minimum levels of coverage for public safety communications within new buildings. In addition, the International Code Council (ICC) and the National Fire Protection Association (NFPA) are currently pursuing the adoption of national-level model codes and standards to help ensure that improved in-building coverage is addressed on a nationwide basis.
RF SIGNAL BOOSTERS (also referred to as RF REPEATERS AND BI- DIRECTIONAL AMPLIFIERS)
Bird® Signal Boosters provide reliable coverage in disadvantaged RF locations to satisfy the needs of the First Responders, Public Safety/Governmental agencies and Private System Users.
There are two different classes of Signal Boosters: Class A and Class B. • Class A (Channelized) will only amplify those discrete channels intended to be retransmitted. - The Bird® SBIII Series Signal Boosters are Class A. • Class B (Broadband) will amplify all signals within the designated pass-band. - The Bird® SBI and SBII Series Signal Boosters are Class B. - The Bird® SBIII can also be configured as a Class B Signal Booster.
Bird Technologies offers different Signal Booster families to meet the unique needs of the different industries.
• VHF Legacy - Accommodates most Public Safety and commercial applications in the 132-174 MHz range. • SBI - Exceptional balance of performance and value for extended coverage of radio communications networks. Covers full Public Safety band in accordance with latest FCC configuration code. Models are available for indoor and outdoor applications. • SBII - Considered the industry standard for Mission Critical LMR / Public Safety Signal Boosters. It covers UHF, 700/800/900 MHz frequencies and is part of the *RescueLine product family. • SBIII - Offers programmable filter flexibility design to master the challenges of a changing RF environment. It covers 700/800MHz. The 700/800 Digital Booster model is also part of the *RescueLine product family.
*RescueLine Signal Boosters - Complies with New International Fire Code and National Fire Protection Association (IFC/NFPA) Standards.
HYBRID DIRECTIONAL COUPLERS Used for power division and signal distribution applications. The broad array of splits facilitates balanced signal distribution in the most comprehensive systems. Additionally, the Tri-Band products allow multi-band signal distribution via a single transmission line where multi-agency communication systems are required. They largely eliminate the near-far problem and maximize the cost-efficiency of the signal boosters. Bi-directional nature of the couplers allows them to be used for two-way communications with minimal loss above the desired coupling value.
CROSSBAND COUPLERSAllow multiband operation of tower transmission lines, reducing cost and tower loading. They are for transmit or receive operations with DC pass-thru models for tower mount Rx systems. Cascading certain models will allow three frequency bands to use one transmission line.
POWER DIVIDERS Hybrid designs are characterized by port-to-port isolation of 20 dB or more and are typically used in receiver multicoupler or low power signal booster applications. Stripline splitters have no port-to-port isolation and are most typically used to feed transmitter power to multiple antennas for phased arrays or similar applications.
SAMPLERSSignal Samplers are non-directional taps for sampling RF signals from a main transmission line, with minimal effect to the power level of the signals on the main line.
1-866-695-4569 www.birdrf.com 1
www.birdrf.com 1-866-695-45692
SB A
pplic
atio
n Sy
stem
Des
ign
Signal Booster Application System Design Questionnaire
www.birdrf.com 1-866-695-45692
1-866-695-4569 www.birdrf.com 3
SB Application System
Design
Signal Booster Application System Design Questionnaire
c. Need Battery backup (please describe the exact requirement) _______________________ d. Enclosure preference (default choice is grey painted steel NEMA4) ___________________ e. Alarm/monitoring system (default choice is Form C contact) _________________________
4. Additional information (important for digital channel-selective booster application)
a. What type of modulation is the signal? ______________ Is it Simulcast? _____________
b. What is the modulation BW of the signal (6.25 kHz, 12.5 kHz, 25 kHz)? ________________ c. What type of Channel Access method is the signal (TDMA or CDMA)? _________________
5. DAS Design: if you need help designing the DAS system, please answer the following questions.
a. Radiating cable, distributed antennas, or need recommendation from us? _____________________
b. Make and model of cable you plan to use ________________________ c. Please provide blueprints of floor layout including dimensions, and indicate:
i. Which floors require coverage ___________________________
ii. Preferred location of the signal booster ________________________
iii. Location of rooftop donor antenna ________________________
iv. Location of risers to run cable between floors ___________________________
v. Any known problem areas such as clean rooms, x-ray labs, and etc.
vi. Any additional comment related to the DAS ______________________________________
6. Business information:
a. When do you need the quote by? (Typical quote turn-around time is 1 week after we receive the completed questionnaire.) __________________________________________________________________
b. What is the expected order date? ____________________________________________________
c. What is the expected installation date? ________________________________________________
Additional comments on the application: ________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________
1-866-695-4569 www.birdrf.com 3
www.birdrf.com 1-866-695-45694
VH
F Le
gacy
Sig
nal B
oost
erVHF Legacy Signal Booster
VHF Legacy Signal Booster accommodates most Public Safety and commercial applications in the 132-174 MHz range. Taking a modular approach, configured systems are easily accommodated by the proper selection of standard amplifier and filter blocks to meet the requirement. Output Level Control (OLC) effectively reduces the gain when input signal levels become too great. This standard feature insures that the signal booster remains linear and therefore maintains its certified output characteristics. Unique filter solutions enable use of these signal boosters in harsh RF environments. The models listed provide one way communications. Two-way configurations are available upon request.
Model Number Frequency Range Passband Gain Gain Adjustment
3rd Order Output Intercept Point
RF Sampler Noise Figure without attenuation
60-38-02-OLC-XX* 132-174 MHz 1 MHz nominal +74 dB 3 & 6 pads +42 dBm min., with no attenuation
PA Output sampler ports
6.5 dB max
60-38-02-OLC-CF-XX* 132-174 MHz 15 kHz (Includes crystal filter)
+66 dB 3 & 6 pads +42 dBm min., with no attenuation
PA Output sampler ports
6.5 dB max
Electrical Specifications
Housing Options Dimensions Operating Temperature Range Net Weight FCC Certification
G1 = Painted Steel - NEMA 4G2 = Stainless Steel - NEMA 4XRM = 19” Rack Mount
20” x 16” x 6”(508 x 406.4 x 152.4 mm)
-30°C to +60°C 50 lbs (22.68 kg.) EZZ5PI860701Class B Type Booster:Type acceptance under FCC Rules Part 90
Mechanical Specifications
Impedance VSWR Input/Output connectors
RF SamplerConnectors
AC Power Input
Unit Power Consumption (AC/DC)
50 ohm <2.0:1 N (F) BNC (F) 100-240 VAC50-60 Hz
1.0 Amp AC/ 1.0 Amp DC
50 ohm <2.0:1 N (F) BNC (F) 100-240 VAC50-60 Hz
1.0 Amp AC/ 1.0 Amp DC
* XX = Housing Options
www.birdrf.com 1-866-695-45694
1-866-695-4569 www.birdrf.com 5
Signal Booster SBI SeriesSignal Booster SBI Series
SB I Series family of signal boosters provides an exceptional balance of performance and value for extended coverage of radio communications networks. Covers full Public Safety band in accordance with latest FCC configuration code. Models for indoor and outdoor applications.
Gain Min. Attenuation (dB)
Gain Flatness (dB)
Noise Figure (dB)
Manual Attenuation Range (dB) Gain Adjustment
Output CompositePower (dBm)
3rd Order Output Intercept Point (dBm) @ 2 tones + 22 dBm ea.
Input/Output Impedance
VSWR IN/OUT
Propagation Delay [uSec]
AC Power Input
Unit Power Consumption (AC/DC)
80 +/- 1.5 (Max.)
5 (Max.) 0 to 30 in 2-dB steps
Low Power: +25.5 (Min.) - Uplink, +25.5 (Min.) - Downlink*High Power: +25.5 (Min.) - Uplink, +33 (Min.) - Downlink*
Low Power: +41 (Min.) - Uplink, +41 (Min.) - Downlink*High Power: +41 (Min.) - Uplink, +50 (Min.) - Downlink*
50 ohm 1.5:1 (Max.)
<1.0 85-150 VAC. (47-63 Hz) Above 150 V available,Consult factory
45 watts
Electrical Specifications
Paint Dimensions Operating Temperature Range Weight
Corrosion Protection, Powder Coat (Taupe)
15.3” x 15.4” x 7.9” (may vary by model)
-30°C to +50°C 33 lbs (may vary by model)
Mechanical Specifications
**CELLULAR OPTIONS
Cellular A = 824-835/ 869-880MHzCellular B = 835-849/880-894MHzCellular AB = 824-849/869-894MHz
1-866-695-4569 www.birdrf.com 5
www.birdrf.com 1-866-695-45696
Sign
al B
oost
er S
BI S
erie
sSignal Booster SBI Series
Model Number Description
62-83E-ADB-02-T3 794-806/764-776 MHz, 806-816/851-861 MHz, 80 dB, 1/1W
62-83E-ADB-04-T3 794-806/764-776 MHz, 806-816/851-861 MHz, 80 dB, 1/10W
DUAL BAND 700/800 MHz*
Model Number Description
62-83E-ADB-02-T3*** 794-806/764-776 MHz, 806-824/851-869 MHz, 80 dB, 1/1W
62-83E-ADB-04-T3*** 794-806/764-776 MHz, 806-824/851-869 MHz, 80 dB, 1/10W
62-83M-ADB-02-T3 794-806/764-776 MHz, 806-816/851-861 MHz, 80 dB, 1/1W
62-83M-ADB-04-T3 794-806/764-776 MHz, 806-816/851-861 MHz, 80 dB, 1/10W
LMR 800 MHz*
Model Number Description
62-89B-A03-01-T3 806-809/851-854 MHz 80dB,1/1W, 3 MHz
62-89B-A03-03-T3 806-809/851-854 MHz 80dB,1/10W, 3 MHz
62-90A-A03-01-T3 821-824/866-869 MHz 80dB,1/1W, 3 MHz
62-90A-A03-03-T3 821-824/866-869 MHz 80dB,1/10W, 3 MHz
NASPAC CHANNELS APPLICATIONS*
Model Number Description
62-91A-A11-01-T3 824-835/869-880 MHz 80dB, 1/1W, 11 MHz
62-91A-A11-03-T3 824-835/869-880 MHz 80dB, 1/10W, 11 MHz
62-91-A25-01-T3 824-849/869-894 MHz 80dB, 1/1W, 25 MHz
62-91-A25-03-T3 824-849/869-894 MHz 80dB, 1/10W, 25 MHz
62-91B-A14-01-T3 835-849/880-894 MHz 80dB, 1/1W, 14 MHz
62-91B-A14-03-T3 835-849/880-894 MHz 80dB, 1/10W, 14 MHz
SB I SERIES SIGNAL BOOSTERS CELLULAR A, B, & A/B BANDS**
Model Number Description
62-91A-A11-01-TR-ALS 824-835/869-880 MHz, 80dB, 1/1W, 11 MHz With Alarm & Sampler
62-91A-A11-03-TR-ALS 824-835/869-880 MHz, 80dB, 1/1W, 11 MHz With Alarm & Sampler
62-91-A25-01-TR-ALS 824-849/869-894 MHz, 80dB, 1/1W, 25 MHz With Alarm & Sampler
62-91-A25-03-TR-ALS 824-849/869-894 MHz, 80dB, 1/1W, 25 MHz With Alarm & Sampler
62-91B-A14-01-TR-ALS 835-849/880-894 MHz, 80dB, 1/1W, 14 MHz With Alarm & Sampler
62-91B-A14-03-TR-ALS 835-849/880-894 MHz, 80dB, 1/1W, 14 MHz With Alarm & Sampler
CELLULAR FOR HARSH ENVIRONMENTS** (ALS Feature included)
*ALS OPTIONS: To add Alarm and Sampler features add-ALS to the end of the part numbers that don’t already have it. Ex. 62-89A-A-18-01-TR-ALS
**CELLULAR BANDSA= 824-835/ 869-880MHzB= 835-849/880-894MHzAB= 824-849/869-894MHz
Please choose a Model Number that meets your needs.
www.birdrf.com 1-866-695-45696
1-866-695-4569 www.birdrf.com 7
Signal Booster SBII SeriesSignal Booster SBII Series UHF/700/800/900
Mission Critical Reliability for In-building Coverage . . .
The Bird® Signal Booster II provides Public Safety grade reliability and coverage in disadvantaged RF locations for First Responders, Public Safety/Governmental agencies and Private System Users. Reliable RF coverage is gained in basements, parking garages, correctional facilities, courthouses, hospitals, malls and schools. Other challenging environments covered by the Signal Booster II product include subways and rapid transit systems, airports, stadiums/arenas, high-rise buildings and large private enterprise facilities and campuses.
Whether you are on the front line and depend on a reliable communication system or you are the systems integrator responsible for implementing a dependable system, this new compact design facilitates installation and system optimization for rock solid operation via a simple intuitive web browser interface. Embedded features for ease of initial setup include decoupled test points for signal level detection, menu driven gain setting, front panel LED monitors for amplifier and power status, and an at-a-glance LED bar graph to indicate relative level of Output Level Control (OLC). Additionally, this product offers a unique on-board OLC DataLog feature that archives a User Signal Profile to facilitate optimum system configuration and performance.
Min. Gain (dB)* (depending on model)
Gain Adjustment
3rd Order Output Intercept Point
Max. Input Level
RF Sampler
Operating Temp. Range
Nominal Impedance
Input/Output connectors
RF Sampler Connectors
AC Power Input
DC Input Voltage
Housing Nominal size
+45 dB+60 dB+80 dB
Programmable attenuation,0-30 dB, 0.5 dB steps
+54 dBm minimum,with no attenuation
0 dBm PA Output sampler (-30 dB)
-30°C to +50° C
50 ohm, <1.5:1 VSWR
N female BNC female 100-240 VAC; 50-60 Hz
+24 to +27 VDC
Painted Steel NEMA, Stainless Steel NEMA 4X, 19 inch Rack Mount
24” x 24” x 8”
Electrical Specifications
Net Weight
Maximum Output Power
Noise Figure (without attenuations)
Propagation Delay Unit Power Consumption (AC/DC)
FCC Certification Industry Canada Certification
130 lbs +32 dBm max(single carrier)
406-430 MHz:8 dB max for narrow BW3 dB max for wide BW430-512 MHz:8 dB max for Medium Gain, High Gain (Head end)11 dB max for Low Gain (In Line)
406-512 MHz: <0.5µs 406-512 MHz: <150 VA 406-512 MHz:EZZ5PI616550
406-512 MHz:1940A-PI616550
< 85 lbs 764-806 MHz+32 dBm max (single carrier)
764-806 MHz:6.5 dB max for Low Gain (In-Line) & Medium Gain3.5 dB max for High Gain (Head-End)
764-806 MHz: <0.5µs 764-806 MHz: <150 VA 764-806 MHz:EZZ5PI618350
764-806 MHz:1940A-PI618350
< 85 lbs 806-869 MHz+32 dBm max (single carrier)
806-869 MHz:6.5 dB max for Low Gain (In-Line) & Medium Gain3.5 dB max for High Gain (Head-End)
806-869 MHz: <0.5µs 806-869 MHz: <150 VA 806-869 MHz: EZZ5PI031202
806-869 MHz: 1940A-PI031202
< 85 lbs 896-941 MHz+32 dBm max (single carrier)
896-941 MHz:6.5 dB max for Low Gain (In-Line) & Medium Gain3.5 dB max for High Gain (Head-End)
896-941 MHz: <0.5µs 896-941 MHz: <150 VA 896-941 MHz: EZZ5PI618850
896-941 MHz: 1940A-PI618850
1-866-695-4569 www.birdrf.com 7
www.birdrf.com 1-866-695-45698
Sign
al B
oost
er S
BII S
erie
sSignal Booster SBII Series UHF/700/800/900
Product ID Band Standard or RescueLine Gain (dB) Filter Width(Based on Frequency)
Enclosure Options
61 = Signal Booster II UHF
65 = 406-430 MHz70 = 450-470 MHz 71 = 470-490 MHz 72 = 490-512 MHz
50 = SBII 2-Way, Standard60 = SBII 2-Way, RescueLine62 = SBII 2-Way, RescueLine with SNMP
A = 80 Gain B = 60 Gain C = 45 Gain
0.15 = Bandwidth 0.15 MHz 0.5 = Bandwidth 0.5 MHz 0.75 = Bandwidth 0.75 MHz 0.8 = Bandwidth 0.8 MHz 1.0 = Bandwidth 1.0 MHz 1.25 = Bandwidth 1.25 MHz 2.0 = Bandwidth 2.0 MHz 3.0 = Bandwidth 3.0 MHz 5.0 = Bandwidth 5.0 MHz
G1 = Gray Painted Steel G2 = Stainless SteelRM = Rack Mount
Blank = No OptionsHE = Fiber Head End: HERE = Fiber Remote End: REDP = Dual Port Head End: DPDPR = Dual Port Remote End: DPR
61 = Signal Booster II700/800/900
83B = 764-806 MHz 88 = 890-960 MHz 89A = 806-869 MHz
50 = SBII 2-Way, Standard60 = SBII 2-Way, RescueLine62 = SBII 2-Way, RescueLine with SNMP
A = 80 Gain B = 60 Gain C = 45 Gain
03 = Bandwidth 03 MHz 05 = Bandwidth 05 MHz06 = Bandwidth 06 MHz07 = Bandwidth 07 MHz10 = Bandwidth 10 MHz12 = Bandwidth 12 MHz15 = Bandwidth 15 MHz18 = Bandwidth 18 MHz
G1 = Gray Painted Steel G2 = Stainless SteelRM = Rack Mount
Blank = No OptionsHE = Fiber Head End: HERE = Fiber Remote End: REDP = Dual Port Head End: DPDPR = Dual Port Remote End: DPR
SBII Selection Guide
Frequency Valid Filter Widths (bold= outside USA)
UHF 65 0.8, 1.0, 2.0, 3.0, 5.0
70 0.15, 0.5, 0.75, 1.0, 1.25, 2.0
71 0.15, 0.5, 0.75, 1.0
72 0.15, 0.5, 0.75, 1.0
700/800/900 83B 12
88 05, 06
89A 03, 05, 06, 7-10, 10, 15, 18
Valid Filter Widths By Frequency
61 - _______ - _______ - _______ - _______ - _______
Optional Products
Example: 61-65-50-A0.8-G1-HE
Battery Backup Unit 6160-H Series Remote Communication Card 6150-COM Voice/Pager Dialer 6150-Page
Provides uninterrupted backup voltage. Complete Remote Accessibility. Select 1-3 message repeats.
Backup supply is provided by a pair of high capacity lead acid batteries. Remote Configuration of Critical Operating Parameters. Program up to 4 separate input channels with individually enable/disable.
Maintain 24 hrs of continuous operation. Remote Access to Critical Component Statues. Store up to 8 telephone/pager numbers.
LED status indicators and auxiliary alarm connections for remote monitoring. Remote Access to OLC Datalog. Reliable emergency notification 24 hrs a day.
NOTE: Not all combinations are valid. If assistance is needed consult with the factory to define the model that is right for you. Standard Dual Band 700/800 and custom models available upon request.
Please use the Selection Guide below to create the Signal Booster that meets your needs.
www.birdrf.com 1-866-695-45698
1-866-695-4569 www.birdrf.com 9
Signal Booster SBIII 700-800 SeriesSignal Booster SBIII 700-800 Series
Filters Frequency Range
Filter Bandwidth
Max. Gain
Output Power
Max. Input Level
RF Input/OutputImpedance
External RF Connectors
Alarms Control & Monitoring
Power
1-30 uplink filters per band1-30 downlink filters per band
700 Band = 764-776, 794-806 MHz800 Band = 806-824, 851-869 MHz
Programmable standard filters include 12.5 kHz, 12.5 kHz low delay, 25 kHz, 3 MHz, 9 MHz. Other custom filters can be configured by the user or factory to meet specific system requirements.
95 dB High Power +34 dBmLow Power +22 dBm(single carrier)
-20 dBm 50 ohm nominal
N-Female Form-C Contacts (NO or NC)
Intuitive web browser interface over an Ethernet connection,local individual module status LED’s.
90-250 VAC, 50/60 Hz or -48 VDC
Electrical Specifications
Operating Temperature Range Enclosure Type Weight FCC Certification** Industry Canada Certification**
-30 °C to +60 °C Modified NEMA 4 w/o Fans 70 lbs. single band95 lbs. dual band
EZZ6138 1940A-6138
Mechanical Specifications
**Class A Type Booster Equipment Authorization under FCC Rules Part 90, Canada Certification Part RSS-131
Product Type
Frequency Band Filter Selection Uplink/Downlink (Power or Technology)
Enclosure Options
613 = 700/800 Digital Booster
83B = 764-806 MHz83E = 764-869 MHz89A = 806-869 MHz
A = 1 x 14 (700 MHz) or (800 MHz) FilterB = 1 x 30 (700 MHz) or (800 MHz) FilterAA = 1 x 14 (700 MHz) Filter & 1 x 14 (800 MHz) FilterBB = 1 x 30 (700 MHz) Filter & 1 x 30 (800 MHz) FilterAB = 1 x 14 (700 MHz) Filter & 1 x 30 (800 MHz) FilterBA = 1 x 30 (700 MHz) Filter & 1 x 14 (800 MHz) Filter
HH = High Power Uplink & DownlinkHL = High Power Uplink & Low Power DownlinkLH = Low Power Uplink & High Power DownlinkLL = Low Power Uplink & DownlinkFH = High Power Fiber RemoteFL = Low Power Fiber RemoteHF = High Power Fiber Head-EndLF = Low Power Fiber Head-End
G1 = Painted EnclosureG2 = Stainless Steel Enclosure
Blank = No OptionsN - NFPA/IFC ConfigurationP - 10 MHz High Precision ReferenceD - -48VDCH - Dual Port (Head End)N - NFPA/IFC ConfigurationR - Dual Port (Remote End)1 - 3 MHz Preselector NPSPAC Pre-Rebanding (866-869 MHz)2 - 3 MHz Preselector NPSPAC Post-Rebanding (851-854 MHz)3 - 10 MHz Preselector (851-861 MHz)
SBIII 700-800 Series Selection Guide
Example: 613-83B-AFH-G1, Signal Booster, 764-806 MHz, SBIII, 1x14 FLTR, High Power, Fiber Remote, Painted Gray Enclosure
613 - _______ - _______ _______ - _______ - _______
Digital Signal Booster operates in the 700/800 MHz range with 1-60programmable digital filters for both uplink and downlink. Filter center frequency and characteristics are fully programmable to meet the demands of various systems and signals. Filter bandwidth is user programmable from 6.25 kHz to 15 MHz. All state-of-the-art product components are protected by a NEMA 4 style enclosure to meet the demands of the NFPA requirements. Intuitive web browser interface allows booster to be easily configured for changing RF environments.
NOTE: Not all combinations are valid. If assistance is needed consult with the factory to define the model that is right for you.
Please use the Selection Guide below to create the Signal Booster that meets your needs.
1-866-695-4569 www.birdrf.com 9
www.birdrf.com 1-866-695-456910
Sign
al B
oost
er S
BIII
UH
F Se
ries
Signal Booster SBIII 450-488 Series
Filters Frequency Range
Filter Bandwidth
Max. Gain
Output Power
Max. Input Level
RF Input/OutputImpedance
External RF Connectors
Alarms Control & Monitoring
Power
1-28 uplink filters per band1-28 downlink filters per band
450-470 MHz470-488 MHz
Programmable standard filters include 12.5 kHz, 12.5 kHz low delay, 25 kHz. Other custom filters can be configured by the user or factory to meet specific system requirements.
95 dB High Power +32 dBmLow Power +22 dBm(single carrier)
-20 dBm 50 ohm nominal
N-Female Form-C Contacts (NO or NC)
Intuitive web browser interface over an Ethernet connection,local individual module status LED’s.
90-250 VAC, 50/60 Hz or +24 VDC
Electrical Specifications
Operating Temperature Range Enclosure Type Weight FCC Certification** Industry Canada Certification**
-30 °C to +60 °C Modified NEMA 4 w/o Fans 95 lbs. single band Pending Pending
Mechanical Specifications
**Class A or B type booster equipment (depending on how it is configured) authorization under FCC Rules Part 90, Canada Certification Part RSS-131
Product Type FR: Frequency Band # Channels Channel Power Enclosure/NFPA Power
614 = UHF Digital Signal Booster
70 = 450-470 MHz 70A = 470-488 MHz
A = 14 Channels B = 28 Channels
HH = High Power UL / High Power DL HL = High Power UL / Low Power DL LH = Low Power UL / High Power DL LL = Low Power UL / Low Power DL
G1 = Gray Steel G2 = StainlessN = NFPA/Red Steel
B = AC with DC Backup
SBIII 450-488 Series Selection Guide
Example: 614-70-A-HH-G1-B = Digital Signal Booster, 450-470 MHz, 14 Channels, High Power UL / High Power DL, Gray Steel, AC with DC Backup
614 - _______ - _______ - _______ - _______ - _______
NOTE: If assistance is needed consult with the factory to define the model that is right for you.
Please use the Selection Guide below to create the Signal Booster that meets your needs.
Bird Technologies, TX RX Systems Digital Signal Booster operates in the UHF frequency band with 1-60 programmable digital filters for both uplink and downlink. Filter center frequency and characteristics are fully programmable to meet the demands of various systems and signals. Filter bandwidth is user programmable from 6.25 kHz to 1.5 MHz. All state-of-the-art product components are protected by a NEMA 4 style enclosure to meet the demands of the NFPA requirements. Intuitive web browser interface allows the booster to be easily configured for changing RF environments.
www.birdrf.com 1-866-695-456910
1-866-695-4569 www.birdrf.com 11
Hybrid D
irectional CouplersHybrid Directional Couplers
Freqency Range Decoupled Value (dB)
Thruline Loss (dB)
Power. Ratio vs Decoupled Ports
5-Watt Load Model No. (2.8 lbs)
25-Watt Load Model No. (3.2 lbs)
No Load Model No. (2.6 lbs)
Dimensions “A” “ B”
VHF, UHF & 800 MHz Harmonic (144-174 MHz, 450-530 MHz and 806-890 MHz)
-3.0 ± 0.7 -3.0 ± 0.3 50%/50% 85-05-01 85-05-0101 85-05-01-LT 18.5 17.875
-4.8 ± 0.7 -1.8 ± 0.3 67%/33% 85-05-02 85-05-0201 85-05-02-LT 18.5 17.875
-6.0 ± 0.7 -1.2 ± 0.3 75%/25% 85-05-03 85-05-0301 85-05-03-LT 18.5 17.875
-7.0 ± 1.0 -1.0 ± 0.2 80%/20% 85-05-04 85-05-0401 85-05-04-LT 18.5 17.875
-10 ± 1.0 -0.5 ± 0.2 90%/10% 85-05-05 85-05-0501 85-05-05-LT 18.5 17.875
-15 -0.2 97%/3% 85-05-06 85-05-0601 85-05-06-LT 18.5 17.875
-20 -0.2 99%/1% 85-05-07 85-05-0701 85-05-07-LT 18.5 17.875
-30 -0.2 99.9%/0.1% 85-05-08 85-05-0801 85-05-08-LT 18.5 17.875
132-174 MHz -3.0 ± 0.7 -3.0 ± 0.3 50%/50% 85-38-01 85-38-0101 85-38-01-LT 18.5 17.875
-4.8 ± 0.7 -1.8 ± 0.3 67%/33% 85-38-02 85-38-0201 85-38-02-LT 18.5 17.875
-6.0 ± 0.7 -1.2 ± 0.3 75%/25% 85-38-03 85-38-0301 85-38-03-LT 18.5 17.875
-7.0 ± 1.0 -1.0 ± 0.2 80%/20% 85-38-04 85-38-0401 85-38-04-LT 18.5 17.875
-10 ± 1.0 -0.5 ± 0.2 90%/10% 85-38-05 85-38-0501 85-38-05-LT 18.5 17.875
350-520 MHz -3.0 ± 0.7 -3.0 ± 0.3 50%/50% 85-58-01 85-58-0101 85-58-01-LT 9.0 8.375
-4.8 ± 0.7 -1.8 ± 0.3 67%/33% 85-58-02 85-58-0201 85-58-02-LT 9.0 8.375
-6.0 ± 0.7 -1.2 ± 0.3 75%/25% 85-58-03 85-58-0301 85-58-03-LT 9.0 8.375
-7.0 ± 1.0 -1.0 ± 0.2 80%/20% 85-58-04 85-58-0401 85-58-04-LT 9.0 8.375
-10 ± 1.0 -0.5 ± 0.2 90%/10% 85-58-05 85-58-0501 85-58-05-LT 9.0 8.375
-15.0 ± 1.0 -0.2 97%/3% 85-58-06 85-58-0601 85-58-06-LT 9.0 8.375
-20.0 ± 1.0 -0.2 99%/1% 85-58-07 85-58-0701 85-58-07-LT 9.0 8.375
-30.0 ± 1.0 -0.2 99.9%/0.1% 85-58-08 85-58-0801 85-58-08-LT 9.0 8.375
746-960 MHz -3.0 ± 0.7 -3.0 ± 0.3 50%/50% 85-83-01 85-83-0101 85-83-01-LT 6.5 5.875
-4.8 ± 0.7 -1.8 ± 0.3 67%/33% 85-83-02 85-83-0201 85-83-02-LT 6.5 5.875
-6.0 ± 0.7 -1.2 ± 0.3 75%/25% 85-83-03 85-83-0301 85-83-03-LT 6.5 5.875
-7.0 ± 1.0 -1.0 ± 0.2 80%/20% 85-83-04 85-83-0401 85-83-04-LT 6.5 5.875
-10 ± 1.0 -0.5 ± 0.2 90%/10% 85-83-05 85-83-0501 85-83-05-LT 6.5 5.875
-15 -0.2 97%/3% 85-83-06 85-83-0601 85-83-06-LT 6.5 5.875
-20 -0.2 99%/1% 85-83-07 85-83-0701 85-83-07-LT 6.5 5.875
-30 -0.2 99.9%/0.1% 85-83-08 85-83-0801 85-83-08-LT 6.5 5.875
Electrical Specifications
Hybrid Directional Couplers for power division and signal distribution applications. The broad array of splits facilitates balanced signal distribution in the most comprehensive systems. Additionally, the Tri-Band products allow multi-band signal distribution via a single transmission line where multi-agency communication systems are required. They largely eliminate the near-far problem and maximize the cost-efficiency of the signal boosters. Bi-directional nature of the couplers allows them to be used for two-way communications with minimal loss above the desired coupling value.
1-866-695-4569 www.birdrf.com 11
www.birdrf.com 1-866-695-456912
Hybrid Directional CouplersH
ybri
d D
irec
tion
al C
oupl
ers FEATURES
}Alodine Gold finish.
}Silver plated N female connectors with gold plated pins.
}Multiple load configurations (no load, 5W, or 25W) available for different power requirements.
www.birdrf.com 1-866-695-456912
1-866-695-4569 www.birdrf.com 13
Crossband Couplers
Model Number Type of Mounting Frequency BandsCoupled (MHz)
Typical Loss (dB) Isolation (dB) Power Rating Watts Notes
80-05-01 Weatherproof Tower Mount 406-512 806-960
0.20 0.20 40 750 500
80-05-02 Base Station Mount 406-512 806-960
0.20 0.20 40 750 500
80-05-03 Weatherproof Tower Mount 406-512 806-960
0.30 0.50 40 Receive Only 1
80-05-04 Weatherproof Tower Mount 406-512 806-960
0.30 0.50 40 250 Receive Only 2
80-05-05 Base Station Mount 406-512 806-960
0.30 0.50 40 250 Receive Only 2
80-05-06 Base Station Mount 25-175 406-960
0.25 0.25 40 350 350
80-05-07 Weatherproof Tower Mount 25-175 406-960
0.25 0.25 40 350 350
80-05-08 Base Station Mount 25-175 406-960
0.35 0.50 40 Receive Only 3
80-05-09 Weatherproof Tower Mount 25-175 406-960
0.35 0.50 40 Receive Only 3
80-05-10 Weatherproof Tower Mount 406-512 806-960
0.35 0.35 40 Receive Only 4
Electrical Specifications
Notes:
1. 80-05-03 will pass DC power between center conductors of all three terminals for operating separate Tower Mount receive systems. WARNING: Do Not connect a DC grounded antenna directly to this Crossband Coupler if DC power is being passed. 2. DC will pass only between the transmission line terminal and the 800 MHz terminal for operating an 800MHz Receive Tower Mount preamplifier. The UHF branch contains a series high current input capacitor to block DC and pass transmit power. 3. DC power passes through UHF and is blocked from VHF to Antenna terminal 4. DC power passes through UHF and is blocked from 800MHz to Antenna terminal
Crossband Couplers
Crossband Couplers allow multiband operation of tower transmission lines, reducing cost and tower loading. They are for transmit or receive operations with DC pass-thru models for tower mount Rx systems. Models are available for specialized transmit and receive applications. Cascading certain models will allow three frequency bands to use one transmission line. Complete response curves are available on request.
1-866-695-4569 www.birdrf.com 13
www.birdrf.com 1-866-695-456914
Crossband CouplersCr
ossb
and
Coup
lers
FEATURES
}Tunable capacitors are replaced with large area transmission line structures for greater reliability.
}Cascading certain models will allow three frequency bands to use one transmission line.
}Tower mount models consist of the base station unit, less rack bar, in a weatherproof fiberglass housing which is sealed with silicone rubber adhesive.
www.birdrf.com 1-866-695-456914
1-866-695-4569 www.birdrf.com 15
Power D
ivider Power Divider
Model Number
Frequency Range No. of Outputs X-Way Splitter Power Rating - Input Insertion Loss Ratio of Output-Input Connectors
84-01-09 10-512 MHz 2 125 W -3.2 dB 50% N (M)
84-01-11 25-512 MHz 2 Rx only -3.2 dB 50% N (F)
84-01-12 25-512 MHz 4 Rx only -6.4 dB 25% N (F)
84-37-01 144-174 MHz 2 800 W -3.2 dB 50% N (F)
84-37-02 144-174 MHz 4 1000 W -6.4 dB 25% N (F)
84-58-01 350-520 MHz 2 800 W -3.2 dB 50% N (F)
84-58-02 350-520 MHz 4 1000 W -6.4 dB 25% N (F)
84-83-01 746-960 MHz 2 Rx Only -3.2 dB 50% N (F)
84-83-02 746-960 MHz 4 RX Only -6.4 dB 25% N (F)
84-83-12 746-960 MHz 3 500 W -5.1 dB 33% N (F)
84-83-14 746-960 2 500 W -6.4 dB 25% N (F)
84-83-17 746-960 MHz 4 500 W -6.4 dB 25% N (F)
Electrical Specifications
Power dividers are grouped into Hybrid/Wilkensen and Stripline/coaxial designs. Hybrid designs are characterized by port-to-port isolation of 20 dB or more and are typically used in receiver multicoupler or low power signal booster applications. Stripline splitters have no port-to-port isolation and are most typically used to feed transmitter power to multiple antennas for phased arrays or similar applications. The models below are characterized by low-loss above the splitting loss and wide bandwidths. N connectors are standard.
1-866-695-4569 www.birdrf.com 15
www.birdrf.com 1-866-695-456916
RF S
igna
l Sam
pler
sRF Signal Samplers
Model Number
Frequency Band Coupling Loss - Thruline-Sampled
Power Split Ratio -Thruline-Sampled
VSWR Power Connector Input -Thruline-Sampled
84-38-10-xx 132-174 MHz -0.9/-10 dB 10/90 % <1.5:1 (<2.0:1 for Sampled Port) 5 W See Model Matrix
84-38-15-xx 132-174 MHz -0.3/-15 dB 3/97 % <1.5:1 10 W See Model Matrix
84-38-20-xx 132-174 MHz -0.1/-20 dB 1/99 % <1.5:1 30 W See Model Matrix
84-38-30-xx 132-174 MHz -0.1/-30 dB 0.1/99.9 % <1.5:1 50 W See Model Matrix
84-38-50-xx 132-174 MHz -0.1/-50 dB 0.001/99.999 % <1.5:1 50 W See Model Matrix
84-58-10-xx 350-520 MHz -0.9/-10 dB 10/90 % <1.5:1 (<2.0:1 for Sampled Port) 5 W See Model Matrix
84-58-15-xx 350-520 MHz -0.3/-15 dB 3/97 % <1.5:1 (<2.0:1 for Sampled Port) 10 W See Model Matrix
84-58-20-xx 350-520 MHz -0.1/-20 dB 1/99 % <1.5:1 30 W See Model Matrix
84-58-30-xx 350-520 MHz -0.1/-30 dB 0.1/99.9 % <1.5:1 50 W See Model Matrix
84-58-50-xx 350-520 MHz -0.1/-50 dB 0.001/99.999 % <1.5:1 50 W See Model Matrix
84-83-10-xx 746-960 MHz -1/-10 dB 10/90 % <1.5:1 (<2.0:1 for Sampled Port) 5 W See Model Matrix
84-83-15 746-960 MHz -0.3/-15 dB 3/97 % <1.5:1 10 W See Model Matrix
84-83-20 746-960 MHz -0.2/-20 dB 1/99 % <1.5:1 30 W See Model Matrix
84-83-30 746-960 MHz -0.1/-30 dB 0.1/99.9 % <1.5:1 50 W See Model Matrix
84-83-50 746-960 MHz -0.1/-50 dB 0.001/99.999 % <1.5:1 50 W See Model Matrix
Electrical Specifications
Signal Samplers are non-directional taps for sampling RF signals from a main transmission line, with minimal effect to the power level of the signals on the main line. The sampled port can be connected to a Spectrum Analyzer for analysis and measurement, or connected to a low gain, distribution antenna in Signal Boosters systems to augment communications in buildings and tunnels. We offer a broad range of sampling levels to accommodate a wide variety of applications.
84-FF-DD-XX-Series, Signal Samplers
Connector Designator (XX) -01 -02 -03
Input N (Female) N (Female) N (Female)
Thruline N (Female) N (Female) N (Male)
Sampled N (Female) BNC (Female) BNC (Female)
Model Matrix
Example: 84-38-10-0184 - _______ - _______ - _______
NOTE: Not all combinations are valid. If assistance is needed consult with the factory to define the model that is right for you.
www.birdrf.com 1-866-695-456916
30303 Aurora Rd. :: Solon, OH 44139 :: 866.695.4569 :: www.birdrf.com
The Bird® Technologies brands include: Bird Electronic, TX RX Systems, X-COM Systems and DeltaNode.Bird® Technologies reserves the right to modify specifications or discontinue any product without notice.
©2014 Bird TechnologiesINBC-11062014
Bird Technologies® is a recognized leader in various segments of the
RF industry from test equipment to DAS, infrastructure and high speed
data capture and analysis. Each Bird brand specializes in a different area
of RF Expertise. X-COM Systems™, TX RX Systems™, DeltaNode™ and
Bird Electronic® together serve as The RF Experts in cellular, land mobile
radio, broadcast, semiconductor, government, military and
medical markets with one common goal – to provide our customers
with the highest quality, innovative RF products and services all
based around total reliability.
All Bird products can be serviced and calibrated by the Bird Service
Center (BSC). Bird Service Centers and Service Partners are located World
Wide providing a full range of service and support for your Bird Products.
To view the catalog online or download, go to www.birdrf.com
www.birdrf.com
In-Building Coverage