IMPORTANT INSTRUCTIONS - Lumascape - … IMPORTANT INSTRUCTIONS ForInstallationofLS684,LS685,LS686,...

14
Ensure good drainage soil C1084US - 2006_07_REV001 Further information over page IMPORTANT INSTRUCTIONS A START HERE 90 o A.C.N. 010 572 773 Mount Fixture. Mount fixture such that the top lip of flange is flush with finished floor level, as shown above. 3 Insert lamp into fixture. Check lamp type and wattage with gear tray. Insert lamp into lampholder (Follow lamp manufacturers instructions). Clean any marks from reflector with dry, soft, lint free cloth. Turn on. 5 7 Lock Gimbal. Remove any accessories and whilst exerting downward pressure on gimbal, tighten grub screw. WARNING DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IF CABLE ASSEMBLY IS TAMPERED WITH. Relamping Brackets indicate instalation steps above Isolate Fixture 10-15 MIN. Run (8) Reseal (9) 4 Open fixture and Unlock. Loosen screws with allen key provided. If necessary gently lever lid out with large screwdriver. Remove components as shown. Loosen grub screw. Target Gimbal. With lamp illuminated insert any accessory lenses and rotate gimbal until targeted as required. Note the finger relief in casting should point towards target. 6 8 Run Fixture. See Over. Replace accessories and allow fixture to burn for 10-15 minutes to allow any moisture in fixture to evaporate. 10-15 MIN. 60 30 45 Re-lamp (5) 60 60 30 30 45 45 Remove Lid For Installation LS343 CFL, PAR, HPS, MV Ingrounds MODELS LS343-23* * ** ** 25 * * LS343-24* * ** ** 25 * * LS343-25* * ** ** 25 * * LS343-26* * ** ** 25 * * FLUSH LID 256MM (10.08") RECESSED LID 240MM (9.45") Do not use power tools to tighten screws. Do not exert downward force on screws while not fully tightened. Do not overtighten screws. CAUTION 1 Locate Fixtures. Site fixture, in proximity to cabling, in gravel, soil or concrete. Use discretion in locating fixtures as glass can become very hot and may burn. 240mm (9 / ") 1 2 FINISHED FLOOR LEVEL DEPTH DEPENDANT ON FIXTURE CONFIG. 250MM (10") 290MM (11 / ") 35 1 2 0MM (13 / ") 3 4 2 Connect junction box (direct burial splice box) to supply conduit as per instructions. For cable only entry connect underwater rated cable in accordance with local wiring rules. Alternatively, if ordered with 1/2"NPT conduit adaptor connect ensuring watertight seal. LS343 Fixture Finished Floor Level Supply Conduit Junction Box(Direct burial splice box) Warning: Overcurrent protection for secondary circuit must be provided at the supply transformer in accordance with the National Electric Code. Supply Connection North America Only If cable damaged replace with cable supplied by LUMASCAPE only. FOR INDOOR AND OUTDOOR USE US Head Office Telephone Fax 1300 Industrial Rd., Unit #19 San Carlos, CA 94070 USA 1-(650)-595-LUMA(5862) 1-(650)-595-5820 Free Call www.lumascape.com (US & Canada) 1-866-695-LUMA(5862) LUMASCAPE USA INC. INC.

Transcript of IMPORTANT INSTRUCTIONS - Lumascape - … IMPORTANT INSTRUCTIONS ForInstallationofLS684,LS685,LS686,...

Ensure gooddrainage soil

C1084US - 2006_07_REV001

Furtherinformationover page

IMPORTANT INSTRUCTIONS

ASTART

HERE

90o

A.C.N. 010 572 773

Mount Fixture.Mount fixture such that thetop lip of flange is flush withfinished floor level, asshown above.

3

Insert lamp into fixture.Check lamp type andwattage with gear tray.Insert lamp into lampholder(Follow lamp manufacturersinstructions).Clean any marks fromreflector with dry, soft, lintfree cloth. Turn on.

5

7

Lock Gimbal.Remove any accessoriesand whilst exertingdownward pressure ongimbal, tighten grub screw.

WARNING

DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.

Relamping

Brackets indicate

instalation steps

aboveIsolate Fixture

10-15 MIN.

Run (8) Reseal (9)

4

Open fixture and Unlock.Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.

Target Gimbal.With lamp illuminated insertany accessory lenses androtate gimbal until targetedas required. Note the fingerrelief in casting should pointtowards target.

6 8

Run Fixture.

See Over.

Replace accessories andallow fixture to burn for10-15 minutes to allow anymoisture in fixture toevaporate.

10-15 MIN.

60

30

45

Re-lamp (5)

6060

3030

4545

Remove Lid

For Installation LS343 CFL, PAR, HPS, MV IngroundsMODELS LS343-23* * ** ** 25 * *

LS343-24* * ** ** 25 * *LS343-25* * ** ** 25 * *LS343-26* * ** ** 25 * *

FLUSH LID

256MM (10.08")

RECESSED LID

240MM (9.45")

Do not use power tools totighten screws. Do not exertdownward force on screwswhile not fully tightened.Do not overtighten screws.

CAUTION 1

Locate Fixtures.Site fixture, in proximity tocabling, in gravel, soil orconcrete. Use discretion inlocating fixtures as glasscan become very hot andmay burn.

Æ240mm (9 / ")1

2FINISHEDFLOOR LEVEL

DEPTHDEPENDANTON FIXTURECONFIG.250MM (10")290MM (11 / ")

35

1

2

0MM (13 / ")3

4

2

Connect junction box (direct burialsplice box) to supply conduit as perinstructions. For cable only entryconnect underwater rated cable inaccordance with local wiring rules.Alternatively, if ordered with 1/2"NPTconduit adaptor connect ensuringwatertight seal.

LS343Fixture

FinishedFloor Level

SupplyConduit

JunctionBox(Directburial splicebox)

Warning: Overcurrent protection forsecondary circuit must be provided atthe supply transformer in accordancewith the National Electric Code.

Supply Connection

North America Only

If cable damaged replace with cable supplied by LUMASCAPE only.

FOR INDOOR AND OUTDOOR USE

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

Seal Fixture.Ensure seal and sealingsurface is clean. Cleanglass if necessary. Tightenlid screws using the 3mmAllen key supplied. DO NOTOVERTIGHTEN.

9

LAMP SOURCE CONVERSION INSTRUCTION

A

D E

Replace/Insert Gimbal andLamp

6

Connect and insert gimbalinto fixture. Remove reflectorand insert new lamp, (Checkwattage and type with gearlabel). Refer installationinstruction Over.

F

Adjust, Aim, Test and Seal

7,8,9

10,11,12

If necessary, readjust andre-aim gimbal position asper instructions over.Test and seal fixture asper Instructions .

Isolate and OpenFixtureEnsure the fixture iselectrically isolated.Loosen the screwswith the Allen Keyprovided. If necessarygently lever lid out witha large screwdriver.

Remove GimbalRemove gimbal by loosening thelocking screw and pulling vertically.

B C

Remove Gear AssemblyRemove gear assembly bypulling vertically (Note: Gearassembly may be screwedto fixture body).

GEARASSEMBLY

Insert New Gear AssemblyAlign holes in gear tray withThreaded Guide Pins inbase of fixture and insertfully, fit S/S nuts to retainGear Tray.

GUIDEPINS

7

8

9

GIMBALLOCKINGSCREW

IMPORTANT INSTRUCTIONS

B

For Installation LS343 CFL, PAR, HPS, MV Ingrounds

WARNING

DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.

90o

A.C.N. 010 572 773

MODELS LS343-23* * ** ** 25 * *LS343-24* * ** ** 25 * *LS343-25* * ** ** 25 * *LS343-26* * ** ** 25 * *

NORTH AMERICA only:As per 2002 NEC Section 305. The SOOW cord mustbe at least 450mm (18 in.) below a minimum 2 inchthick concrete slab.

C1084US - 2006_07_REV001

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

www.lumascape.com.au

IMPORTANT INSTRUCTIONS

For Installation of LS684, LS685, LS686,Filter Support Accessories

MODELS LS684 - LS343 Refractor Gimbal Ht Glass/filter SupportLS685 - LS343 Refractor Gimbal Linear Spreader/filter SupportLS686 - LS343 Refractor Gimbal Dichroic Filter/filter Support

A.C.N. 010 572 773

C957US - 2006_07_REV001

IMPORTANT

Ensure that glare shieldis

fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.

, ifsupplied - VN models only,

For Very Narrow Refractors -

GlareShield

RefractorSpacer

Lens

Reflector

SecondaryGlass

Note

Additional filters, (137mm x3mm Max) can be added tothe fixture by retainingbeneath spring clips on thetop of the secondary glass

Additional filter

1

Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.

Open fixture

UW & VNMetal HalideOnly

2

Insert new filter assemblyinto fixture. The glass sideof the assembly should beclosest to the lamp

Replace filter assembly

4

Replace Filter and lensand outer cover assemblyand reseal fixture.

Replace lens and lid

www.lumascape.com.au

IMPORTANT INSTRUCTIONS

For Installation of LS684, LS685, LS686,Filter Support Accessories

MODELS LS684 - LS343 Refractor Gimbal Ht Glass/filter SupportLS685 - LS343 Refractor Gimbal Linear Spreader/filter SupportLS686 - LS343 Refractor Gimbal Dichroic Filter/filter Support

A.C.N. 010 572 773

C957US - 2006_07_REV001

IMPORTANT

Ensure that glare shieldis

fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.

, ifsupplied - VN models only,

For Very Narrow Refractors -

GlareShield

RefractorSpacer

Lens

Reflector

SecondaryGlass

Note

Additional filters, (137mm x3mm Max) can be added tothe fixture by retainingbeneath spring clips on thetop of the secondary glass

Additional filter

1

Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.

Open fixture

UW & VNMetal HalideOnly

2

Insert new filter assemblyinto fixture. The glass sideof the assembly should beclosest to the lamp

Replace filter assembly

4

Replace Filter and lensand outer cover assemblyand reseal fixture.

Replace lens and lid

Intentionally Left Blank Intentionally Left Blank

Free Call:

1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)

Fax: 1-(650)-595-5820

1300 Industrial Rd., Unit #19

San Carlos, CA 94070, USA

LUMASCAPE CONTACT DETAILS

LUMASCAPE USA INC.Free Call:

1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)

Fax: 1-(650)-595-5820

1300 Industrial Rd., Unit #19

San Carlos, CA 94070, USA

LUMASCAPE CONTACT DETAILS

LUMASCAPE USA INC.

Furtherinformationover page

IMPORTANT INSTRUCTIONS

ASTART

HERE

MODELS LS651, LS652, LS654, LS655, LS657, LS658Human Touch Retro-Fit Kits for LS343 Series

A.C.N. 010 572 773

For Installation LS343 Human Touch Retro-Fit Kits

Instruction GuideIMPORTANT NOTE:Human Touch kits are available for LS343 series fixtures in 290mm& 350mm Bodies ONLY!

For Kit Numbers. Follow Instructions Sets

C

LS657, LS658 Instruction Set Followed by Instruction Set

LS654, LS655 Instruction Set Followed by Instruction Set

A C

B C

LS651, LS652 Instruction Set Only

Check the fixture is electricallyisolated. Unscrew & removelid. Loosen gimbal lockingscrew and remove assembly.

Isolate and remove Gimbal

Gimballocking screw

1

Ensure two hooks on clip areinterlocked

Join clip ends

2

Connect & insert gimbal intofixture. Re-adjust Rotation,angle & depth. Lock offGimbal.

Return Gimbal into Fixture

4 6

Insert reflector glass into clipon reflector. Ensure glass isflat and central againstreflector. Avoid touchingGlass as best as possible.

Insert Reflector Glass

Instruction Set A REFLECTOR GLASS ATTACHMENT FOR LS657, LSD658 ONLY

3

Positioning the join under thelip of the reflector. Stretch theclip over the reflector asshown

Attach Clip to Reflector

5

Gimbal rotationlocking screw

Gimbal heightlocking screw

Re-aim gimbal to desiredfocal point. Lock gimbal depthand rotation.

Adjust Gimbal position

C825US - 2006_07_REV001

WARNING

DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

Furtherinformationover page

IMPORTANT INSTRUCTIONS

Check the fixture is electricallyisolated. Unscrew & removelid.

Isolate and remove Lid

1

Check fixture is cool to touchand remove the hood andlouvre

Remove louvre and hood

2 3

Attach the new hood, filterlouvre assembly to gimbal

Attach new Hood Assembly

Instruction Set B LAMP GLASS ATTACHMENT FOR LS654 LS655 ONLY

Gently position the sealevenly into the top of thefixture

Locate Sealed Glass

1

Pushing on the seal itself,press the seal into the fixturewith an even pressure

Push Seal Evenly

2 3

Ensure the seal is locatedevenly against the gimbal.Care must be taken not tomis-align the gimbal.

Check position

Gimbal

Seal/Glass

Instruction Set C SEAL GLASS ATTACHMENT FOR ALL LS343 HUMAN TOUCH KITS

5

Peal seal away from glass.Check that seal is clean.Insert new glass into seal.

Replace Glass

4

Remove the lid and screwsfrom the lid seal.

Seperate Lid

6

Reassembly Lid into seal,aligning holes.Insert screws into holes.Clean both sides of glass andreseal fixture.

Reassemble Lid & Clean

Instructions 4, 5 & 6 Applicable only with kits LS651, LS654 & LS657

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

C825US - 2006_07_REV001

IMPORTANT INSTRUCTIONS

MODELS LS692, LS693Human Touch Retro-Fit Kits for LS343 Series

A.C.N. 010 572 773

For Installation LS343 Human Touch Retro-Fit Kits

Instruction GuideIMPORTANT NOTE:Human Touch kits are available for LS343 series fixtures in 290mm& 350mm Bodies ONLY!

C1140US - 2006_07_REV001

WARNING

DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.

Check the fixture is electricallyisolated. Unscrew & removelid.

Isolate and remove Lid

1

Screw filter onto filter ring

Screw in filter

2

Close fixture

3

Check the fixture is electricallyisolated. Unscrew & removelid.

Isolate and remove Lid

1

Align keyed edge of filter withfixture and drop into place

Insert filter

2

Close fixture

3

LS692

LS693

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

IMPORTANT INSTRUCTIONS

For Installation LS343

1

ASTART

HERE

C772US - 2006_07_REV001

Furtherinformationover pageSEE OTHER SIDE

FOR RE-LAMPING

MODELS LS343 Inground90

o

A.C.N. 010 572 773

Do not use power tools totighten screws. Do not exertdownward force on screwswhile not fully tightened.Do not overtighten screws.

CAUTION

Site fixture, in proximity tocabling, in gravel, soil orconcrete. Use discretion inlocating fixtures as glasscan become very hot andmay burn.

Locate Fixtures

Æ240mm (9 / ")1

2FINISHEDFLOOR LEVEL

DEPTHDEPENDANTON FIXTURECONFIG.250MM (10")290MM (11 / ")

35

1

2

0MM (13 / ")3

4

Mount fixture with either toplip or bottom surface offlange, flush with finishedfloor level, as shown above.

Mount Fixture

FLUSH LID

256MM (10.08")

RECESSED LID

240MM (9.45")3

DOMED LID

245MM (9.65")

37MM (1.46")

5

Check lamp WATTAGE,VOLTAGE, and TYPE, andinsert into lampholder (referto lamp manufacturersdocumentation for handlingprecautions).

Insert Lamp

Adjust the vertical positionof the gimbal to minimiseglare, and tighten lockingscrew. Rotate gimbal todesired direction and tightenlocking screw.

Adjust Gimbal Position.

GIMBALHEIGHTLOCKINGSCREW

6

GIMBALROTATIONLOCKINGSCREW

Test to ensure fixture isoperational. Allow to burnfor 10-15 minutes to allowany moisture in fixture toevaporate.

Test Fixture10-15 MIN.

60

30

45

7

Ensure seal and sealingsurface is clean. Cleanglass if necessary. Tightenlid screws using the 3mmAllen key supplied. DO NOTOVERTIGHTEN.

Seal Fixture

8

4

SECURE GEARTRAYWITH SUPPLIED NUTS.

Geartray is to be aligned withThreaded Guide Pins in baseand retained with S/S nutssupplied to prevent gear trayfrom falling loose.

Fix Geartray with Nuts

2

Connect junction box to supplyconduit as per instructions.For cable only entry connectunderwater rated cable in accordancewith local wiring rules.Alternatively, if ordered with 1/2"NPTconduit adaptor connect ensuringwatertight seal.

LS343Fixture

FinishedFloor Level

SupplyConduit

JunctionBox

Warning: Overcurrent protection forsecondary circuit must be provided atthe supply transformer in accordancewith the National Electric Code.

Supply Connection

North America Only

WARNING

DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.

Note: If cable damaged replace with cable supplied by LUMASCAPE only.

NORTH AMERICA only:As per 2002 NEC Section 305. The SOOW cord must be aleast 450mm (18 in.) below a minimum 2 inch thick concrete slab.

FOR INDOOR AND OUTDOOR USE

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

IMPORTANT INSTRUCTIONS

B

For Installation LS343MODELS LS343 Inground

90o

A.C.N. 010 572 773

A

Ensure the fixture iselectrically isolated. Loosenthe screws with the AllenKey provided. If necessarygently lever lid out with alarge screwdriver.

Isolate and Open Fixture

B

Replace Lamp

Remove old lamp and checkcondition of lampholder.Check new lamp WATTAGE,VOLTAGE and TYPE. Insertnew lamp,(Refer installationinstruction 4 over.)

C

If necessary, readjust andre-aim gimbal position.Test and seal fixture asper installation Instructions

through to , over.6 8

Adjust, Aim, Test and Seal

RELAMPING

6

6

7 8

LAMP SOURCE CONVERSION INSTRUCTION

1

4 5

Replace Lamp

Remove old lamp and checkcondition of lampholder.Check new lamp WATTAGE,VOLTAGE and TYPE. Insertnew lamp,(Refer installationinstruction 4 over.)

6

If necessary, readjust andre-aim gimbal position.Test and seal fixture asper installation Instructions

through to , over.6 8

Adjust, Aim, Test and Seal

Ensure the fixture iselectrically isolated.Loosen the screwswith the Allen Keyprovided. If necessarygently lever lid outwith a largescrewdriver.

Isolate andOpen Fixture

GIMBALLOCKINGSCREW

Remove gimbal by loosening thelocking screw and pulling vertically.

Remove Gimbal

2 3

Remove gear assembly bypulling vertically (Note: Gearassembly may be screwedto fixture body).

Remove Gear Assembly

GEARASSEMBLY

Align holes in gear tray withThreaded Guide Pins inbase of fixture and insertfully, fit S/S nuts to retainGear Tray.

Insert New Gear Assembly

GUIDEPINS

6

6

7 8

FOR INDOOR AND OUTDOOR USE

C772US - 2006_07_REV001

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

Ensure gooddrainage soil

Do not use power tools totighten screws. Do not exertdownward force on screwswhile not fully tightened.Do not overtighten screws.

CAUTION 1

Locate Fixtures.Site fixture, in proximity tocabling, in gravel, soil orconcrete. Use discretion inlocating fixtures as glasscan become very hot andmay burn.

Æ240mm (9 / ")1

2FINISHEDFLOOR LEVEL

DEPTHDEPENDANTON FIXTURECONFIG.250MM (10")290MM (11 / ")

35

1

2

0MM (13 / ")3

4

2

Connect junction box (direct burialsplice box) to supply conduit as perinstructions.For cable only entry connectunderwater rated cable in accordancewith local wiring rules.Alternatively, if ordered with 1/2"NPTconduit adaptor connect ensuringwatertight seal.

LS343Fixture

FinishedFloor Level

SupplyConduit

JunctionBox (Directburial splicebox)

Warning: Overcurrent protection forsecondary circuit must be provided atthe supply transformer in accordancewith the National Electric Code.

Supply Connection

North America Only

Furtherinformationover page

ASTART

HERE

Mount Fixture.Mount fixture such that thetop lip of flange is flush withfinished floor level, asshown above.

FLUSH LID

256MM (10.08")

RECESSED LID

240MM (9.45")3

Insert lamp into fixture.Unscrew reflector andremove. Insert lamp intolampholder and test.Replace reflector. To ensurereflector does not bind dueto heat screw all the waydown, then back off 1/8th ofa turn

4

Tilt Adjust

RotationalLock

Tilt AngleIndicator

AimingMark

Gimbal Features.

Target Gimbal 1.

Aiming MarkRotate gimbal until the

is targeted asdesired.

5

20o

20o

40o

Target Gimbal 2.

Tilt Adjust

Tilt AngleIndicator

Adjust gimbal tilt angle byrotating screwwith Allen key supplied.Approximate angle can beread from the

.

6

Lock Gimbal.Whilst exerting downwardpressure on gimbal, tightenRotational Lock grub screw.

7

WARNING

DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.

Relamping

Brackets indicate

instalation steps

aboveIsolate Fixture

10-15 MIN.6060

3030

4545

Run (9)Remove Lid Re-lamp (4) Reseal (10)

IMPORTANT INSTRUCTIONS

For Installation LS343 MH, Halospot, Ingrounds90

o

A.C.N. 010 572 773

MODELS LS343-22* * ** ** 25 * *LS343-291* * ** ** 25 * *

C1082US - 2006_07_REV001

If cable damaged replace with cable supplied by LUMASCAPE only.

FOR INDOOR AND OUTDOOR USE

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

Refractor

Indexedfilter

Screw onfilters

Accessories.Add accessories. Noteinstructions supplied withaccessory. Further gimbaladjustments may berequired with accessoriesin place.

8

10-15 MIN.

60

30

45

Run Fixture.Allow to burn for 10-15minutes without lid attachedto allow any moisture infixture to evaporate.

9

Seal Fixture.Ensure seal and sealingsurface is clean. Cleanglass if necessary. Tightenlid screws using the 3mmAllen key supplied. DO NOTOVERTIGHTEN.

10

IMPORTANT INSTRUCTIONS

B

For Installation LS343 MH, Halospot, Ingrounds90

o

A.C.N. 010 572 773

MODELS LS343-22* * ** ** 25 * *LS343-291* * ** ** 25 * *

NORTH AMERICA only:As per 2002 NEC Section 305. The SOOW cord must be at least 450mm (18 in.)below a minimum 2 inch thick concrete slab.

C1082US - 2006_07_REV001

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

IMPORTANT INSTRUCTIONS

C

For Installation LS343 MH, Halospot, Ingrounds90

o

A.C.N. 010 572 773

MODELS LS343-22* * ** ** 25 * *LS343-291* * ** ** 25 * *

LAMP SOURCE CONVERSION INSTRUCTION

A

D E

Replace/Insert Gimbal andLamp

4

Connect and insert gimbalinto fixture. Remove reflectorand insert new lamp, (Checkwattage and type with gearlabel). Refer installationinstruction Over.

F

Isolate and OpenFixtureEnsure the fixture iselectrically isolated.Loosen the screwswith the Allen Keyprovided. If necessarygently lever lid out witha large screwdriver.

Remove GimbalRemove gimbal by loosening thelocking screw and pulling vertically.

B C

Remove Gear AssemblyRemove gear assembly bypulling vertically (Note: Gearassembly may be screwedto fixture body).

GEARASSEMBLY

Insert New Gear AssemblyAlign holes in gear tray withThreaded Guide Pins inbase of fixture and insertfully, fit S/S nuts to retainGear Tray.

GUIDEPINS

GIMBALLOCKINGSCREW

Adjust, Aim, Test and Seal

5,6,7

8,9,10

If necessary, readjust andre-aim gimbal position asper instructions over.Test and seal fixture asper Instructions .

7

8

9

G H

Remove Heat ShieldRemove heat shield(if supplied) by holding onefinger tab and liftingstraight out of fixture

Replace Heat ShieldPush heat shield(if supplied)down into fixtureensuring that the shiny sideis facing up, and that itcomes to rest level atopgear assembly

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

C1082US - 2006_07_REV001

IMPORTANT INSTRUCTIONS

For Installation LS640K-ULMODELS LS640K

Mounting accessory for LS343

Brass Collar.

Stainless Steel Sleeve.

Bolts to anchor sleeve andarrest movement of collar inconcrete.

Styrofoam plug, (Use ifrequired. Ensure removalafter for drainage)

CAUTION; Do not pinch orcut cable beneath sleeve

Finished Floor Level tobe flush with top surfaceof brass collar.

GENERAL ASSEMBLY

6

1. Insert fixture body aligning

holes.

2. Use screw to insert/align seal

3. Insert lid and start only, 1 screw.

4. Insert screw opposite and tighten

5. Insert and tighten all screws.

Do not over tighten.

LID TIGHTENING PROCEDURE

3

FIT SLEEVE, COLLAR AND COVER PLATE

- Fit sleeve over foam plug. Ensure enough cable is in the cavity to connect to fixture.

- Position top lip of mounting collar to be flush with finished floor level.

- Screw cover plate, (order separately), to mounting collar if required.

2

SUPPLY CONNECTION- Position junction box directly

beneath concrete sleeve and connect to supply conduit.

- Punch a hole in foam plug large enough for the connector to pass through

- Pack hole in plug around the cable to ensure concrete doesn't enter the fixture cavity.

(Ensure the cap on the connector is secure)

Layout fixture locations as required.

Use discretion in placement, fixture may become hot and could burn.

Fixture cavity should be as above. Ensure gravel or similar medium forms the bottom of cavity to allow drainage.

HOLE DETAIL - SECTION VIEW

1

430M

M (

1’ 5

“) M

IN

FINISHEDFLOOR LEVEL

GRAVEL

HOLE 265MM

1(10 / “)2

CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical Worker

C419-UL - 2011_10_REV003

Factory supplied junction box. Ensure lid and gasket are replaced.Use gel-filled wire nuts (included) to ensure a wet location compliant electrical connection..

Cable length 900mm (36in)

US Head Office1300 Industrial Rd., Unit #19

San Carlos, CA 94070USA

Telephone1-(650)-595-LUMA(5862)

Fax1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

INC

.

LURC US

MOUNTINGCOLLAR

STAINLESSSTEEL SLEEVE

FINISHEDFLOOR LEVEL

CABLE/JUNCTION BOXASSEMBLY

SUPPLYCONDUIT

FOAMPLUG

FINISHEDFLOOR LEVEL

SPLICEBOX

FIT LS343 FIXTURE

When ready to install fixture;

- Destroy Foam plug.

- Assemble fixture according to LS343 Instruction sheet.

- Remove cover plate (if located).

- Join Quick Connectors (do not dispose of cap).

5

- Pour concrete. Check the top surface of mounting collar is flush with the finished floor level.

POUR CONCRETE

4

CONCRETE

FINISHEDFLOOR LEVEL

CONNECTOR

FOAMPLUG

Connector, plug and cable. Ensure free cable reaches beyond height of collar for fixture connection.

COVER PLATE (LS6047), order separately

DEPTH DEPENDANT ON FIXTURE CONFIGURATION:

3350 mm (13 / ")4

Ensure gooddrainage soil

IMPORTANT INSTRUCTIONS

For Installation LS640MODELS LS640K

Mounting accessory for LS343

5 64

321

Layout fixture locations as required.

Use discretion in placement, fixture may become hot and could burn.

Fixture cavity requirements are as shown above.

FINISHEDFLOOR LEVEL

CAVITY 240 mm

1(9 / )2"

DE

PT

H

CAVITY REQUIREMENTS

TILE/CONCRETEPANEL

GRATE

DECKING

Mount collar securely as required in floor media.

MOUNT COLLAR

If installation of fixture into mounting collar is to be delayed we recommend the installation of a cover plate. Order separately.

TEMPORARY COVER PLATE(LS6047)

SUPPLY CONNECTION

Insert fixture into mounting collar alligning holes in the flange with tapped holes in the collar

MOUNT FIXTURE LAMP, TEST, SEAL.

Complete installation of fixture by inserting lamp, testing and sealing, (As per Instruction 6 over.) according to the LS343 installation instruction sheet.

CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical Worker

LURC US

If supplied with 1/2"NPT adaptor connect in accordance with local wiring rules and ensure a watertight seal.

SUPPLYCONDUIT

JUNCTIONBOX

FINISHEDFLOOR LEVEL

FIXTURE

US Head Office1300 Industrial Rd., Unit #19

San Carlos, CA 94070USA

Telephone1-(650)-595-LUMA(5862)

Fax1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

INC

.

C419-UL - 2011_10_REV003

www.lumascape.com

IMPORTANT INSTRUCTIONS

For Adjusting/Aiming of Refractor LensMODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)

LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)

C898US - 2006_07_REV001

IMPORTANT

Ensure that glare shieldis

fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.

, ifsupplied - VN models only,

For Very Narrow Refractors -

GlareShield

RefractorSpacer

Lens

Reflector

SecondaryGlass

3

Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.

Lock reflector

4

Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.

Replace lens and lid

Note

Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.

Additional filter

1

Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.

Open fixture and Unlock

UW & VNMetal HalideOnly

VN Only

2

Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.

Aim fixture optics

IMPORTANT INSTRUCTIONS

For Adjusting/Aiming of Refractor Lens

C898US - 2006_07_REV001

IMPORTANT

Ensure that glare shieldis

fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.

, ifsupplied - VN models only,

For Very Narrow Refractors -

GlareShield

RefractorSpacer

Lens

Reflector

SecondaryGlass

3

Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.

Lock reflector

4

Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.

Replace lens and lid

Note

Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.

Additional filter

1

Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.

Open fixture and Unlock

UW & VNMetal HalideOnly

VN Only

2

Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.

Aim fixture optics

www.lumascape.com

MODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)

Free Call:

1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)

Fax: 1-(650)-595-5820

1300 Industrial Rd., Unit #19

San Carlos, CA 94070, USA

LUMASCAPE CONTACT DETAILS

LUMASCAPE USA INC.Free Call:

1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)

Fax: 1-(650)-595-5820

1300 Industrial Rd., Unit #19

San Carlos, CA 94070, USA

LUMASCAPE CONTACT DETAILS

LUMASCAPE USA INC.