IMPORTANT INSTRUCTIONS - Lumascape - … IMPORTANT INSTRUCTIONS ForInstallationofLS684,LS685,LS686,...
Transcript of IMPORTANT INSTRUCTIONS - Lumascape - … IMPORTANT INSTRUCTIONS ForInstallationofLS684,LS685,LS686,...
Ensure gooddrainage soil
C1084US - 2006_07_REV001
Furtherinformationover page
IMPORTANT INSTRUCTIONS
ASTART
HERE
90o
A.C.N. 010 572 773
Mount Fixture.Mount fixture such that thetop lip of flange is flush withfinished floor level, asshown above.
3
Insert lamp into fixture.Check lamp type andwattage with gear tray.Insert lamp into lampholder(Follow lamp manufacturersinstructions).Clean any marks fromreflector with dry, soft, lintfree cloth. Turn on.
5
7
Lock Gimbal.Remove any accessoriesand whilst exertingdownward pressure ongimbal, tighten grub screw.
WARNING
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.
Relamping
Brackets indicate
instalation steps
aboveIsolate Fixture
10-15 MIN.
Run (8) Reseal (9)
4
Open fixture and Unlock.Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.
Target Gimbal.With lamp illuminated insertany accessory lenses androtate gimbal until targetedas required. Note the fingerrelief in casting should pointtowards target.
6 8
Run Fixture.
See Over.
Replace accessories andallow fixture to burn for10-15 minutes to allow anymoisture in fixture toevaporate.
10-15 MIN.
60
30
45
Re-lamp (5)
6060
3030
4545
Remove Lid
For Installation LS343 CFL, PAR, HPS, MV IngroundsMODELS LS343-23* * ** ** 25 * *
LS343-24* * ** ** 25 * *LS343-25* * ** ** 25 * *LS343-26* * ** ** 25 * *
FLUSH LID
256MM (10.08")
RECESSED LID
240MM (9.45")
Do not use power tools totighten screws. Do not exertdownward force on screwswhile not fully tightened.Do not overtighten screws.
CAUTION 1
Locate Fixtures.Site fixture, in proximity tocabling, in gravel, soil orconcrete. Use discretion inlocating fixtures as glasscan become very hot andmay burn.
Æ240mm (9 / ")1
2FINISHEDFLOOR LEVEL
DEPTHDEPENDANTON FIXTURECONFIG.250MM (10")290MM (11 / ")
35
1
2
0MM (13 / ")3
4
2
Connect junction box (direct burialsplice box) to supply conduit as perinstructions. For cable only entryconnect underwater rated cable inaccordance with local wiring rules.Alternatively, if ordered with 1/2"NPTconduit adaptor connect ensuringwatertight seal.
LS343Fixture
FinishedFloor Level
SupplyConduit
JunctionBox(Directburial splicebox)
Warning: Overcurrent protection forsecondary circuit must be provided atthe supply transformer in accordancewith the National Electric Code.
Supply Connection
North America Only
If cable damaged replace with cable supplied by LUMASCAPE only.
FOR INDOOR AND OUTDOOR USE
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
Seal Fixture.Ensure seal and sealingsurface is clean. Cleanglass if necessary. Tightenlid screws using the 3mmAllen key supplied. DO NOTOVERTIGHTEN.
9
LAMP SOURCE CONVERSION INSTRUCTION
A
D E
Replace/Insert Gimbal andLamp
6
Connect and insert gimbalinto fixture. Remove reflectorand insert new lamp, (Checkwattage and type with gearlabel). Refer installationinstruction Over.
F
Adjust, Aim, Test and Seal
7,8,9
10,11,12
If necessary, readjust andre-aim gimbal position asper instructions over.Test and seal fixture asper Instructions .
Isolate and OpenFixtureEnsure the fixture iselectrically isolated.Loosen the screwswith the Allen Keyprovided. If necessarygently lever lid out witha large screwdriver.
Remove GimbalRemove gimbal by loosening thelocking screw and pulling vertically.
B C
Remove Gear AssemblyRemove gear assembly bypulling vertically (Note: Gearassembly may be screwedto fixture body).
GEARASSEMBLY
Insert New Gear AssemblyAlign holes in gear tray withThreaded Guide Pins inbase of fixture and insertfully, fit S/S nuts to retainGear Tray.
GUIDEPINS
7
8
9
GIMBALLOCKINGSCREW
IMPORTANT INSTRUCTIONS
B
For Installation LS343 CFL, PAR, HPS, MV Ingrounds
WARNING
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.
90o
A.C.N. 010 572 773
MODELS LS343-23* * ** ** 25 * *LS343-24* * ** ** 25 * *LS343-25* * ** ** 25 * *LS343-26* * ** ** 25 * *
NORTH AMERICA only:As per 2002 NEC Section 305. The SOOW cord mustbe at least 450mm (18 in.) below a minimum 2 inchthick concrete slab.
C1084US - 2006_07_REV001
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
www.lumascape.com.au
IMPORTANT INSTRUCTIONS
For Installation of LS684, LS685, LS686,Filter Support Accessories
MODELS LS684 - LS343 Refractor Gimbal Ht Glass/filter SupportLS685 - LS343 Refractor Gimbal Linear Spreader/filter SupportLS686 - LS343 Refractor Gimbal Dichroic Filter/filter Support
A.C.N. 010 572 773
C957US - 2006_07_REV001
IMPORTANT
Ensure that glare shieldis
fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.
, ifsupplied - VN models only,
For Very Narrow Refractors -
GlareShield
RefractorSpacer
Lens
Reflector
SecondaryGlass
Note
Additional filters, (137mm x3mm Max) can be added tothe fixture by retainingbeneath spring clips on thetop of the secondary glass
Additional filter
1
Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.
Open fixture
UW & VNMetal HalideOnly
2
Insert new filter assemblyinto fixture. The glass sideof the assembly should beclosest to the lamp
Replace filter assembly
4
Replace Filter and lensand outer cover assemblyand reseal fixture.
Replace lens and lid
www.lumascape.com.au
IMPORTANT INSTRUCTIONS
For Installation of LS684, LS685, LS686,Filter Support Accessories
MODELS LS684 - LS343 Refractor Gimbal Ht Glass/filter SupportLS685 - LS343 Refractor Gimbal Linear Spreader/filter SupportLS686 - LS343 Refractor Gimbal Dichroic Filter/filter Support
A.C.N. 010 572 773
C957US - 2006_07_REV001
IMPORTANT
Ensure that glare shieldis
fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.
, ifsupplied - VN models only,
For Very Narrow Refractors -
GlareShield
RefractorSpacer
Lens
Reflector
SecondaryGlass
Note
Additional filters, (137mm x3mm Max) can be added tothe fixture by retainingbeneath spring clips on thetop of the secondary glass
Additional filter
1
Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.
Open fixture
UW & VNMetal HalideOnly
2
Insert new filter assemblyinto fixture. The glass sideof the assembly should beclosest to the lamp
Replace filter assembly
4
Replace Filter and lensand outer cover assemblyand reseal fixture.
Replace lens and lid
Intentionally Left Blank Intentionally Left Blank
Free Call:
1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)
Fax: 1-(650)-595-5820
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
LUMASCAPE CONTACT DETAILS
LUMASCAPE USA INC.Free Call:
1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)
Fax: 1-(650)-595-5820
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
LUMASCAPE CONTACT DETAILS
LUMASCAPE USA INC.
Furtherinformationover page
IMPORTANT INSTRUCTIONS
ASTART
HERE
MODELS LS651, LS652, LS654, LS655, LS657, LS658Human Touch Retro-Fit Kits for LS343 Series
A.C.N. 010 572 773
For Installation LS343 Human Touch Retro-Fit Kits
Instruction GuideIMPORTANT NOTE:Human Touch kits are available for LS343 series fixtures in 290mm& 350mm Bodies ONLY!
For Kit Numbers. Follow Instructions Sets
C
LS657, LS658 Instruction Set Followed by Instruction Set
LS654, LS655 Instruction Set Followed by Instruction Set
A C
B C
LS651, LS652 Instruction Set Only
Check the fixture is electricallyisolated. Unscrew & removelid. Loosen gimbal lockingscrew and remove assembly.
Isolate and remove Gimbal
Gimballocking screw
1
Ensure two hooks on clip areinterlocked
Join clip ends
2
Connect & insert gimbal intofixture. Re-adjust Rotation,angle & depth. Lock offGimbal.
Return Gimbal into Fixture
4 6
Insert reflector glass into clipon reflector. Ensure glass isflat and central againstreflector. Avoid touchingGlass as best as possible.
Insert Reflector Glass
Instruction Set A REFLECTOR GLASS ATTACHMENT FOR LS657, LSD658 ONLY
3
Positioning the join under thelip of the reflector. Stretch theclip over the reflector asshown
Attach Clip to Reflector
5
Gimbal rotationlocking screw
Gimbal heightlocking screw
Re-aim gimbal to desiredfocal point. Lock gimbal depthand rotation.
Adjust Gimbal position
C825US - 2006_07_REV001
WARNING
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
Furtherinformationover page
IMPORTANT INSTRUCTIONS
Check the fixture is electricallyisolated. Unscrew & removelid.
Isolate and remove Lid
1
Check fixture is cool to touchand remove the hood andlouvre
Remove louvre and hood
2 3
Attach the new hood, filterlouvre assembly to gimbal
Attach new Hood Assembly
Instruction Set B LAMP GLASS ATTACHMENT FOR LS654 LS655 ONLY
Gently position the sealevenly into the top of thefixture
Locate Sealed Glass
1
Pushing on the seal itself,press the seal into the fixturewith an even pressure
Push Seal Evenly
2 3
Ensure the seal is locatedevenly against the gimbal.Care must be taken not tomis-align the gimbal.
Check position
Gimbal
Seal/Glass
Instruction Set C SEAL GLASS ATTACHMENT FOR ALL LS343 HUMAN TOUCH KITS
5
Peal seal away from glass.Check that seal is clean.Insert new glass into seal.
Replace Glass
4
Remove the lid and screwsfrom the lid seal.
Seperate Lid
6
Reassembly Lid into seal,aligning holes.Insert screws into holes.Clean both sides of glass andreseal fixture.
Reassemble Lid & Clean
Instructions 4, 5 & 6 Applicable only with kits LS651, LS654 & LS657
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
C825US - 2006_07_REV001
IMPORTANT INSTRUCTIONS
MODELS LS692, LS693Human Touch Retro-Fit Kits for LS343 Series
A.C.N. 010 572 773
For Installation LS343 Human Touch Retro-Fit Kits
Instruction GuideIMPORTANT NOTE:Human Touch kits are available for LS343 series fixtures in 290mm& 350mm Bodies ONLY!
C1140US - 2006_07_REV001
WARNING
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.
Check the fixture is electricallyisolated. Unscrew & removelid.
Isolate and remove Lid
1
Screw filter onto filter ring
Screw in filter
2
Close fixture
3
Check the fixture is electricallyisolated. Unscrew & removelid.
Isolate and remove Lid
1
Align keyed edge of filter withfixture and drop into place
Insert filter
2
Close fixture
3
LS692
LS693
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
IMPORTANT INSTRUCTIONS
For Installation LS343
1
ASTART
HERE
C772US - 2006_07_REV001
Furtherinformationover pageSEE OTHER SIDE
FOR RE-LAMPING
MODELS LS343 Inground90
o
A.C.N. 010 572 773
Do not use power tools totighten screws. Do not exertdownward force on screwswhile not fully tightened.Do not overtighten screws.
CAUTION
Site fixture, in proximity tocabling, in gravel, soil orconcrete. Use discretion inlocating fixtures as glasscan become very hot andmay burn.
Locate Fixtures
Æ240mm (9 / ")1
2FINISHEDFLOOR LEVEL
DEPTHDEPENDANTON FIXTURECONFIG.250MM (10")290MM (11 / ")
35
1
2
0MM (13 / ")3
4
Mount fixture with either toplip or bottom surface offlange, flush with finishedfloor level, as shown above.
Mount Fixture
FLUSH LID
256MM (10.08")
RECESSED LID
240MM (9.45")3
DOMED LID
245MM (9.65")
37MM (1.46")
5
Check lamp WATTAGE,VOLTAGE, and TYPE, andinsert into lampholder (referto lamp manufacturersdocumentation for handlingprecautions).
Insert Lamp
Adjust the vertical positionof the gimbal to minimiseglare, and tighten lockingscrew. Rotate gimbal todesired direction and tightenlocking screw.
Adjust Gimbal Position.
GIMBALHEIGHTLOCKINGSCREW
6
GIMBALROTATIONLOCKINGSCREW
Test to ensure fixture isoperational. Allow to burnfor 10-15 minutes to allowany moisture in fixture toevaporate.
Test Fixture10-15 MIN.
60
30
45
7
Ensure seal and sealingsurface is clean. Cleanglass if necessary. Tightenlid screws using the 3mmAllen key supplied. DO NOTOVERTIGHTEN.
Seal Fixture
8
4
SECURE GEARTRAYWITH SUPPLIED NUTS.
Geartray is to be aligned withThreaded Guide Pins in baseand retained with S/S nutssupplied to prevent gear trayfrom falling loose.
Fix Geartray with Nuts
2
Connect junction box to supplyconduit as per instructions.For cable only entry connectunderwater rated cable in accordancewith local wiring rules.Alternatively, if ordered with 1/2"NPTconduit adaptor connect ensuringwatertight seal.
LS343Fixture
FinishedFloor Level
SupplyConduit
JunctionBox
Warning: Overcurrent protection forsecondary circuit must be provided atthe supply transformer in accordancewith the National Electric Code.
Supply Connection
North America Only
WARNING
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.
Note: If cable damaged replace with cable supplied by LUMASCAPE only.
NORTH AMERICA only:As per 2002 NEC Section 305. The SOOW cord must be aleast 450mm (18 in.) below a minimum 2 inch thick concrete slab.
FOR INDOOR AND OUTDOOR USE
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
IMPORTANT INSTRUCTIONS
B
For Installation LS343MODELS LS343 Inground
90o
A.C.N. 010 572 773
A
Ensure the fixture iselectrically isolated. Loosenthe screws with the AllenKey provided. If necessarygently lever lid out with alarge screwdriver.
Isolate and Open Fixture
B
Replace Lamp
Remove old lamp and checkcondition of lampholder.Check new lamp WATTAGE,VOLTAGE and TYPE. Insertnew lamp,(Refer installationinstruction 4 over.)
C
If necessary, readjust andre-aim gimbal position.Test and seal fixture asper installation Instructions
through to , over.6 8
Adjust, Aim, Test and Seal
RELAMPING
6
6
7 8
LAMP SOURCE CONVERSION INSTRUCTION
1
4 5
Replace Lamp
Remove old lamp and checkcondition of lampholder.Check new lamp WATTAGE,VOLTAGE and TYPE. Insertnew lamp,(Refer installationinstruction 4 over.)
6
If necessary, readjust andre-aim gimbal position.Test and seal fixture asper installation Instructions
through to , over.6 8
Adjust, Aim, Test and Seal
Ensure the fixture iselectrically isolated.Loosen the screwswith the Allen Keyprovided. If necessarygently lever lid outwith a largescrewdriver.
Isolate andOpen Fixture
GIMBALLOCKINGSCREW
Remove gimbal by loosening thelocking screw and pulling vertically.
Remove Gimbal
2 3
Remove gear assembly bypulling vertically (Note: Gearassembly may be screwedto fixture body).
Remove Gear Assembly
GEARASSEMBLY
Align holes in gear tray withThreaded Guide Pins inbase of fixture and insertfully, fit S/S nuts to retainGear Tray.
Insert New Gear Assembly
GUIDEPINS
6
6
7 8
FOR INDOOR AND OUTDOOR USE
C772US - 2006_07_REV001
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
Ensure gooddrainage soil
Do not use power tools totighten screws. Do not exertdownward force on screwswhile not fully tightened.Do not overtighten screws.
CAUTION 1
Locate Fixtures.Site fixture, in proximity tocabling, in gravel, soil orconcrete. Use discretion inlocating fixtures as glasscan become very hot andmay burn.
Æ240mm (9 / ")1
2FINISHEDFLOOR LEVEL
DEPTHDEPENDANTON FIXTURECONFIG.250MM (10")290MM (11 / ")
35
1
2
0MM (13 / ")3
4
2
Connect junction box (direct burialsplice box) to supply conduit as perinstructions.For cable only entry connectunderwater rated cable in accordancewith local wiring rules.Alternatively, if ordered with 1/2"NPTconduit adaptor connect ensuringwatertight seal.
LS343Fixture
FinishedFloor Level
SupplyConduit
JunctionBox (Directburial splicebox)
Warning: Overcurrent protection forsecondary circuit must be provided atthe supply transformer in accordancewith the National Electric Code.
Supply Connection
North America Only
Furtherinformationover page
ASTART
HERE
Mount Fixture.Mount fixture such that thetop lip of flange is flush withfinished floor level, asshown above.
FLUSH LID
256MM (10.08")
RECESSED LID
240MM (9.45")3
Insert lamp into fixture.Unscrew reflector andremove. Insert lamp intolampholder and test.Replace reflector. To ensurereflector does not bind dueto heat screw all the waydown, then back off 1/8th ofa turn
4
Tilt Adjust
RotationalLock
Tilt AngleIndicator
AimingMark
Gimbal Features.
Target Gimbal 1.
Aiming MarkRotate gimbal until the
is targeted asdesired.
5
20o
20o
40o
Target Gimbal 2.
Tilt Adjust
Tilt AngleIndicator
Adjust gimbal tilt angle byrotating screwwith Allen key supplied.Approximate angle can beread from the
.
6
Lock Gimbal.Whilst exerting downwardpressure on gimbal, tightenRotational Lock grub screw.
7
WARNING
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IFCABLE ASSEMBLY IS TAMPERED WITH.
Relamping
Brackets indicate
instalation steps
aboveIsolate Fixture
10-15 MIN.6060
3030
4545
Run (9)Remove Lid Re-lamp (4) Reseal (10)
IMPORTANT INSTRUCTIONS
For Installation LS343 MH, Halospot, Ingrounds90
o
A.C.N. 010 572 773
MODELS LS343-22* * ** ** 25 * *LS343-291* * ** ** 25 * *
C1082US - 2006_07_REV001
If cable damaged replace with cable supplied by LUMASCAPE only.
FOR INDOOR AND OUTDOOR USE
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
Refractor
Indexedfilter
Screw onfilters
Accessories.Add accessories. Noteinstructions supplied withaccessory. Further gimbaladjustments may berequired with accessoriesin place.
8
10-15 MIN.
60
30
45
Run Fixture.Allow to burn for 10-15minutes without lid attachedto allow any moisture infixture to evaporate.
9
Seal Fixture.Ensure seal and sealingsurface is clean. Cleanglass if necessary. Tightenlid screws using the 3mmAllen key supplied. DO NOTOVERTIGHTEN.
10
IMPORTANT INSTRUCTIONS
B
For Installation LS343 MH, Halospot, Ingrounds90
o
A.C.N. 010 572 773
MODELS LS343-22* * ** ** 25 * *LS343-291* * ** ** 25 * *
NORTH AMERICA only:As per 2002 NEC Section 305. The SOOW cord must be at least 450mm (18 in.)below a minimum 2 inch thick concrete slab.
C1082US - 2006_07_REV001
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
IMPORTANT INSTRUCTIONS
C
For Installation LS343 MH, Halospot, Ingrounds90
o
A.C.N. 010 572 773
MODELS LS343-22* * ** ** 25 * *LS343-291* * ** ** 25 * *
LAMP SOURCE CONVERSION INSTRUCTION
A
D E
Replace/Insert Gimbal andLamp
4
Connect and insert gimbalinto fixture. Remove reflectorand insert new lamp, (Checkwattage and type with gearlabel). Refer installationinstruction Over.
F
Isolate and OpenFixtureEnsure the fixture iselectrically isolated.Loosen the screwswith the Allen Keyprovided. If necessarygently lever lid out witha large screwdriver.
Remove GimbalRemove gimbal by loosening thelocking screw and pulling vertically.
B C
Remove Gear AssemblyRemove gear assembly bypulling vertically (Note: Gearassembly may be screwedto fixture body).
GEARASSEMBLY
Insert New Gear AssemblyAlign holes in gear tray withThreaded Guide Pins inbase of fixture and insertfully, fit S/S nuts to retainGear Tray.
GUIDEPINS
GIMBALLOCKINGSCREW
Adjust, Aim, Test and Seal
5,6,7
8,9,10
If necessary, readjust andre-aim gimbal position asper instructions over.Test and seal fixture asper Instructions .
7
8
9
G H
Remove Heat ShieldRemove heat shield(if supplied) by holding onefinger tab and liftingstraight out of fixture
Replace Heat ShieldPush heat shield(if supplied)down into fixtureensuring that the shiny sideis facing up, and that itcomes to rest level atopgear assembly
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
C1082US - 2006_07_REV001
IMPORTANT INSTRUCTIONS
For Installation LS640K-ULMODELS LS640K
Mounting accessory for LS343
Brass Collar.
Stainless Steel Sleeve.
Bolts to anchor sleeve andarrest movement of collar inconcrete.
Styrofoam plug, (Use ifrequired. Ensure removalafter for drainage)
CAUTION; Do not pinch orcut cable beneath sleeve
Finished Floor Level tobe flush with top surfaceof brass collar.
GENERAL ASSEMBLY
6
1. Insert fixture body aligning
holes.
2. Use screw to insert/align seal
3. Insert lid and start only, 1 screw.
4. Insert screw opposite and tighten
5. Insert and tighten all screws.
Do not over tighten.
LID TIGHTENING PROCEDURE
3
FIT SLEEVE, COLLAR AND COVER PLATE
- Fit sleeve over foam plug. Ensure enough cable is in the cavity to connect to fixture.
- Position top lip of mounting collar to be flush with finished floor level.
- Screw cover plate, (order separately), to mounting collar if required.
2
SUPPLY CONNECTION- Position junction box directly
beneath concrete sleeve and connect to supply conduit.
- Punch a hole in foam plug large enough for the connector to pass through
- Pack hole in plug around the cable to ensure concrete doesn't enter the fixture cavity.
(Ensure the cap on the connector is secure)
Layout fixture locations as required.
Use discretion in placement, fixture may become hot and could burn.
Fixture cavity should be as above. Ensure gravel or similar medium forms the bottom of cavity to allow drainage.
HOLE DETAIL - SECTION VIEW
1
430M
M (
1’ 5
“) M
IN
FINISHEDFLOOR LEVEL
GRAVEL
HOLE 265MM
1(10 / “)2
CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical Worker
C419-UL - 2011_10_REV003
Factory supplied junction box. Ensure lid and gasket are replaced.Use gel-filled wire nuts (included) to ensure a wet location compliant electrical connection..
Cable length 900mm (36in)
US Head Office1300 Industrial Rd., Unit #19
San Carlos, CA 94070USA
Telephone1-(650)-595-LUMA(5862)
Fax1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
INC
.
LURC US
MOUNTINGCOLLAR
STAINLESSSTEEL SLEEVE
FINISHEDFLOOR LEVEL
CABLE/JUNCTION BOXASSEMBLY
SUPPLYCONDUIT
FOAMPLUG
FINISHEDFLOOR LEVEL
SPLICEBOX
FIT LS343 FIXTURE
When ready to install fixture;
- Destroy Foam plug.
- Assemble fixture according to LS343 Instruction sheet.
- Remove cover plate (if located).
- Join Quick Connectors (do not dispose of cap).
5
- Pour concrete. Check the top surface of mounting collar is flush with the finished floor level.
POUR CONCRETE
4
CONCRETE
FINISHEDFLOOR LEVEL
CONNECTOR
FOAMPLUG
Connector, plug and cable. Ensure free cable reaches beyond height of collar for fixture connection.
COVER PLATE (LS6047), order separately
DEPTH DEPENDANT ON FIXTURE CONFIGURATION:
3350 mm (13 / ")4
Ensure gooddrainage soil
IMPORTANT INSTRUCTIONS
For Installation LS640MODELS LS640K
Mounting accessory for LS343
5 64
321
Layout fixture locations as required.
Use discretion in placement, fixture may become hot and could burn.
Fixture cavity requirements are as shown above.
FINISHEDFLOOR LEVEL
CAVITY 240 mm
1(9 / )2"
DE
PT
H
CAVITY REQUIREMENTS
TILE/CONCRETEPANEL
GRATE
DECKING
Mount collar securely as required in floor media.
MOUNT COLLAR
If installation of fixture into mounting collar is to be delayed we recommend the installation of a cover plate. Order separately.
TEMPORARY COVER PLATE(LS6047)
SUPPLY CONNECTION
Insert fixture into mounting collar alligning holes in the flange with tapped holes in the collar
MOUNT FIXTURE LAMP, TEST, SEAL.
Complete installation of fixture by inserting lamp, testing and sealing, (As per Instruction 6 over.) according to the LS343 installation instruction sheet.
CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical Worker
LURC US
If supplied with 1/2"NPT adaptor connect in accordance with local wiring rules and ensure a watertight seal.
SUPPLYCONDUIT
JUNCTIONBOX
FINISHEDFLOOR LEVEL
FIXTURE
US Head Office1300 Industrial Rd., Unit #19
San Carlos, CA 94070USA
Telephone1-(650)-595-LUMA(5862)
Fax1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
INC
.
C419-UL - 2011_10_REV003
www.lumascape.com
IMPORTANT INSTRUCTIONS
For Adjusting/Aiming of Refractor LensMODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)
LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)
C898US - 2006_07_REV001
IMPORTANT
Ensure that glare shieldis
fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.
, ifsupplied - VN models only,
For Very Narrow Refractors -
GlareShield
RefractorSpacer
Lens
Reflector
SecondaryGlass
3
Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.
Lock reflector
4
Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.
Replace lens and lid
Note
Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.
Additional filter
1
Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.
Open fixture and Unlock
UW & VNMetal HalideOnly
VN Only
2
Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.
Aim fixture optics
IMPORTANT INSTRUCTIONS
For Adjusting/Aiming of Refractor Lens
C898US - 2006_07_REV001
IMPORTANT
Ensure that glare shieldis
fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.
, ifsupplied - VN models only,
For Very Narrow Refractors -
GlareShield
RefractorSpacer
Lens
Reflector
SecondaryGlass
3
Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.
Lock reflector
4
Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.
Replace lens and lid
Note
Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.
Additional filter
1
Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.
Open fixture and Unlock
UW & VNMetal HalideOnly
VN Only
2
Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.
Aim fixture optics
www.lumascape.com
MODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)
Free Call:
1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)
Fax: 1-(650)-595-5820
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
LUMASCAPE CONTACT DETAILS
LUMASCAPE USA INC.Free Call:
1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)
Fax: 1-(650)-595-5820
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
LUMASCAPE CONTACT DETAILS