ImmunoCard STAT! HpSA HD - Meridian Bioscience Inc. Sheet... · immunocard stat!® hpsa® hd next...

2
ImmunoCard STAT! ® HpSA ® HD NEXT GENERATION, HIGH DEFINITION RAPID TEST FROM THE LEADER IN STOOL ANTIGEN TESTING EXPORT ONLY. NOT CLEARED FOR USE IN THE UNITED STATES. A near-patient test demonstrating 98% concordance with Premier Platinum HpSA ® PLUS Simplified sample handling combined with a short incubation time High definition bands for straightforward reading - sharp bands allowing for excellent discrimination between positives and negatives DEFINITIVE ANSWERS, CONFIDENT RESULTS ® www.meridianbioscience.eu

Transcript of ImmunoCard STAT! HpSA HD - Meridian Bioscience Inc. Sheet... · immunocard stat!® hpsa® hd next...

ImmunoCard STAT!® HpSA® HDNEXT GENERATION, HIGH DEFINITION

RAPID TEST FROM THE LEADER IN STOOL ANTIGEN TESTING

EXPORT ONLY. NOT CLEARED FOR USE IN THE UNITED STATES.

• A near-patient test demonstrating 98% concordance with Premier Platinum HpSA® PLUS

• Simplified sample handling combined with a short incubation time

• High definition bands for straightforward reading - sharp bands allowing for excellent discrimination between positives and negatives

DEFINITIVE ANSWERS, CONFIDENT RESULTS®

www.meridianbioscience.eu

POSITIVE AGREEMENT NEGATIVE AGREEMENT

94.3% 99.2%

www.meridianbioscience.eu IC STAT HpSA-HD 10.2014

© 2014 SN750020 REV. 6/2014

Using the applicator stick of the diluent vial, transfer a small portion (5-6 mm diameter) of stool specimen into the sample diluent. Vortex 15 seconds.

Hold the vial vertically and gently tap on benchtop. Break the tip from the vial using absorbent paper.

Dispense 3 drops into the round window of the device and read the result at 5 minutes.

Interpretation of results

Positive Negative Invalid

*This chart does not contain complete instructions for use. For further information, please refer to the package insert.

1. 2. 3.

TEST PROCEDURE

© 2014 SN750020 REV. 6/2014

Using the applicator stick of the diluent vial, transfer a small portion (5-6 mm diameter) of stool specimen into the sample diluent. Vortex 15 seconds.

Hold the vial vertically and gently tap on benchtop. Break the tip from the vial using absorbent paper.

Dispense 3 drops into the round window of the device and read the result at 5 minutes.

Interpretation of results

Positive Negative Invalid

*This chart does not contain complete instructions for use. For further information, please refer to the package insert.

1. 2. 3.

TEST PROCEDURE

© 2014 SN750020 REV. 6/2014

Using the applicator stick of the diluent vial, transfer a small portion (5-6 mm diameter) of stool specimen into the sample diluent. Vortex 15 seconds.

Hold the vial vertically and gently tap on benchtop. Break the tip from the vial using absorbent paper.

Dispense 3 drops into the round window of the device and read the result at 5 minutes.

Interpretation of results

Positive Negative Invalid

*This chart does not contain complete instructions for use. For further information, please refer to the package insert.

1. 2. 3.

TEST PROCEDURE

www.meridianbioscience.eu

Catalog #

Product Quantity

20 Tests 750020

Ordering Information

ImmunoCard STAT!® HpSA® HD

96 Microwells 601396Premier Platinum HpSA® PLUS

30 Tests 710030ImmunoCard® H. pylori

96 Microwells 606096Premier® H. pylori

MERIDIAN BIOSCIENCE EUROPE Germany - Berlin Tel: +49 (0)3371 681 500Italy - Milan Tel: +39 0331 43 36 36France - Paris Tel: +33 1 42 56 04 40Belgium - Braine l’Alleud Tel: +32 67 89 59 59The Netherlands - Veghel Tel: +31 411 62 11 66Web: www.meridianbioscience.euEmail: [email protected]

For other countries, please visit: www.meridianbioscience.eu/distributors

References: ImmunoCard STAT!® HpSA® HD Package Insert, rev. 09/14

WORLD HEADHQUARTERSMeridian Bioscience, Inc.3471 River Hills DriveCincinnati, Ohio 45244 USAWeb: www.meridianbioscience.com

AUSTRALIABioline (Aust) Pty LtdTel: 1 800 993 120Email: [email protected]