Goal: Select the most promising model for geographic HPSA designation to fully test
ImmunoCard STAT! HpSA HD - Meridian Bioscience Inc. Sheet... · immunocard stat!® hpsa® hd next...
Transcript of ImmunoCard STAT! HpSA HD - Meridian Bioscience Inc. Sheet... · immunocard stat!® hpsa® hd next...
ImmunoCard STAT!® HpSA® HDNEXT GENERATION, HIGH DEFINITION
RAPID TEST FROM THE LEADER IN STOOL ANTIGEN TESTING
EXPORT ONLY. NOT CLEARED FOR USE IN THE UNITED STATES.
• A near-patient test demonstrating 98% concordance with Premier Platinum HpSA® PLUS
• Simplified sample handling combined with a short incubation time
• High definition bands for straightforward reading - sharp bands allowing for excellent discrimination between positives and negatives
DEFINITIVE ANSWERS, CONFIDENT RESULTS®
www.meridianbioscience.eu
POSITIVE AGREEMENT NEGATIVE AGREEMENT
94.3% 99.2%
www.meridianbioscience.eu IC STAT HpSA-HD 10.2014
© 2014 SN750020 REV. 6/2014
Using the applicator stick of the diluent vial, transfer a small portion (5-6 mm diameter) of stool specimen into the sample diluent. Vortex 15 seconds.
Hold the vial vertically and gently tap on benchtop. Break the tip from the vial using absorbent paper.
Dispense 3 drops into the round window of the device and read the result at 5 minutes.
Interpretation of results
Positive Negative Invalid
*This chart does not contain complete instructions for use. For further information, please refer to the package insert.
1. 2. 3.
TEST PROCEDURE
© 2014 SN750020 REV. 6/2014
Using the applicator stick of the diluent vial, transfer a small portion (5-6 mm diameter) of stool specimen into the sample diluent. Vortex 15 seconds.
Hold the vial vertically and gently tap on benchtop. Break the tip from the vial using absorbent paper.
Dispense 3 drops into the round window of the device and read the result at 5 minutes.
Interpretation of results
Positive Negative Invalid
*This chart does not contain complete instructions for use. For further information, please refer to the package insert.
1. 2. 3.
TEST PROCEDURE
© 2014 SN750020 REV. 6/2014
Using the applicator stick of the diluent vial, transfer a small portion (5-6 mm diameter) of stool specimen into the sample diluent. Vortex 15 seconds.
Hold the vial vertically and gently tap on benchtop. Break the tip from the vial using absorbent paper.
Dispense 3 drops into the round window of the device and read the result at 5 minutes.
Interpretation of results
Positive Negative Invalid
*This chart does not contain complete instructions for use. For further information, please refer to the package insert.
1. 2. 3.
TEST PROCEDURE
www.meridianbioscience.eu
Catalog #
Product Quantity
20 Tests 750020
Ordering Information
ImmunoCard STAT!® HpSA® HD
96 Microwells 601396Premier Platinum HpSA® PLUS
30 Tests 710030ImmunoCard® H. pylori
96 Microwells 606096Premier® H. pylori
MERIDIAN BIOSCIENCE EUROPE Germany - Berlin Tel: +49 (0)3371 681 500Italy - Milan Tel: +39 0331 43 36 36France - Paris Tel: +33 1 42 56 04 40Belgium - Braine l’Alleud Tel: +32 67 89 59 59The Netherlands - Veghel Tel: +31 411 62 11 66Web: www.meridianbioscience.euEmail: [email protected]
For other countries, please visit: www.meridianbioscience.eu/distributors
References: ImmunoCard STAT!® HpSA® HD Package Insert, rev. 09/14
WORLD HEADHQUARTERSMeridian Bioscience, Inc.3471 River Hills DriveCincinnati, Ohio 45244 USAWeb: www.meridianbioscience.com
AUSTRALIABioline (Aust) Pty LtdTel: 1 800 993 120Email: [email protected]