IMAGE QUALITY

Transcript of IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

Page 1: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

IMAGE QUALITY

Page 2: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

SPATIAL RESOLUTION CONTRAST RESOLUTION

NOISE

IMAGE ARTIFACTS

RADIATIONDOSE

Page 3: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

Resolution in CT

Spatial Resolution Contrast Resolution

Page 4: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

SPATIAL RESOLUTION

• DEGREE OF BLURRING IN THE IMAGE

MEASURE OF THE ABILITY TO DISCRIMINATE OBJECTS OF VARYING DENSITY A SMALL DISTANCE APART

AGAINST A UNIFORM BACKGROUND

Page 5: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

MTFMODULATION TRANSFER

FUNCTION

MOST COMMONLY USED TO DESCRIBE SPATIAL RESOLUTION

IN CT

Page 6: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

MTF

• MTF OF 1 – 100% TRANSFER OF OBJECT TO IMAGE

• MTF OF 0 – 0% TRANSFER OF OBJECT TO IMAGE

Page 7: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

HIGH CONTRAST PHANTOM

Page 8: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Page 9: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Page 10: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

FACTORS AFFECTING SPATIAL RESOLUTION

• SLICE THICKNESS

• FOCAL SPOT SIZE

• DETECTOR WIDTH

• TYPE OF CONVOLUTION FILTER (KERNEL)

• MATRIX SIZE

• FOV

Page 11: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

SLICE THICKNESS

SLICE THICKNESS S. RESOLUTION

5 MM 1 MM

Page 12: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

FOCAL SPOT SIZE

FOCAL SPOT SIZE S. RESOLUTION

LARGE FOCAL SPOT = LARGE PENUMBRA (BLURR)

Page 13: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

DETECTOR WIDTH

DETECTOR WIDTH S. RESOLUTION

Page 14: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

TYPE OF CONVOLUTION FILTER

SHARP KERNEL S. RESOLUTION

SMOOTH SHARP

Page 15: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

MATRIX SIZE

MATRIX SIZE S. RESOLUTION

80 X 80 512 X 512

Page 16: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

DFOV SIZE

DFOV S. RESOLUTION

20CM 10CM

Page 17: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

CONTRAST RESOLUTION

• SENSITIVITY OF THE SYSTEM

• LOW CONTRAST RESOLUTION

• LOW CONTRAST DETECTIBILITY

Page 18: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

LOW CONTRAST RESOLUTION

( TISSUE RESOLUTION)

• THE ABILITY OF AN IMAGING SYSTEM TO DEMONSTRATE SMALL CHANGES IN TISSUE CONTRAST

Page 19: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

CONTRAST RESOLUTION

• SENSITIVITY OF THE SYSTEM

• LOW CONTRAST RESOLUTION

• LOW CONTRAST DETECTIBILITY

Page 20: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

CONTRAST RESOLUTION PHANTOM

Page 21: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

FACTORS AFFECTING LOW CONTRAST RESOLUTION

• PHOTON FLUX

• SLICE THICKNESS

• PATIENT SIZE

• DETECTOR SENSITIVITY

• RECONSTRUCTION ALGORITHM

• IMAGE DISPLAY

• QUANTUM NOISE

Page 22: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

PHOTON FLUX (INTENSITY)

PHOTON FLUX C. RESOLUTION

mAs P. FLUXkVp P. FLUX

Page 23: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

LOW TECHNIQUE ADEQUATE TECHNIQUE

Page 24: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

SLICE THICKNESS

SLICE THICKNESS C. RESOLUTION

8 mm 5 mm

Page 25: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

10 mm – 100 PHOTONS 5 mm – 50 PHOTONS

Page 26: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

PATIENT SIZE

PATIENT SIZE C. RESOLUTION

NORMAL LARGE

Page 27: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

DETECTOR SENSITIVITY

DETECTOR SENSITIVITY C. RESOLUTION

Page 28: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

TYPE OF CONVOLUTION FILTER

SMOOTH KERNEL C. RESOLUTION

SMOOTH SHARP

Page 29: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

IMAGE DISPLAY

MONITOR RESOLUTION C. RESOLUTION

Page 30: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

QUANTUM NOISE

QUANTUM NOISE C. RESOLUTION

HIGH NOISE LOW NOISE

Page 31: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

NOISE IN CT

• FLUCTUATION OF CT# BETWEEN POINTS IN THE IMAGE FOR A SCAN OF UNIFORM MATERIAL SUCH WATER.

Page 32: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Page 33: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

NOISE SOURCES IN CT

• QUANTUM NOISE – X-RAY INTENSITY AT THE DETECTORS

• MATRIX SIZE

• DFOV

• SLICE THICKNESS

• CONVOLUTION FILTER TYPE

• PITCH

Page 34: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

QUANTUM NOISE – CONTROLLED BY THE

TECHNOLOGIST

• mA

• Time

• kVp

NOISE

Page 35: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

NOISE

• QUANTUM (STATISTICAL) –CONTROLLED BY THE TECHNOLOGIST

• ELECTRONIC – INHERENT IN THE EQUIPMENT

Page 36: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

QUANTUM NOISE – CONTROLLED BY THE

TECHNOLOGIST

• DFOV

• MATRIX

• COLLIMATION

• FILTER SPATIAL FREQUENCY

• PITCH

NOISE

Page 37: IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.

DOSE vs

IMAGE QUALITY

• RADIATION DOSE IMAGE QUALITY