E17 g ET23.5 i T11 BT-28S ET-181 BT-37 W E-25
LUMALUX®ILUMALUXPLUST7ECO™Non cycling, environmentally friendlier high pressure sodium.
IPIBB ,70 ET-23/i Mog 67497100 ET-231^ Mog 67559150 ET-23'/£ Mog 67494200 ET-18 Mog 67495250 ET-18 Mog .67572400 ET-18 Mog 67312
OrderingAbbreviation
LU70/PLUS/ECO
ANSISpec.
NumberS62CX
LU100/PLUS/ECO S54CXLU150/55/PLUS/ECO S55CXLU200/PLUS/ECO S66EJLU250/PLUS/ECO S50EJLU400/PLUS/ECO S51EJ
Pkg.dry.202020202020
DescriptionClear28
Clear28
Clear28
Clear28
Clear28
Clear28
LifeAvg.
RatedHours
240002400024000240002400024000
Approx.Lumens
Initial Mean6300 56009500 855016000 1440022000 1980029000 2610050000 45000
LC.L
5
55
5%5%5%
M.O.I.TATATA9%9%9%
STANDARD LUMALUXGeneral lighting high pressure sodium..35 E-17 Med. 67500
; 6750150 E-17 Med. 67502
67503ET-23^ Mog 67510
6751170 E-17 Med. 67504
67505ET-23!^ Mog 67512
67513100 E-17 Med. 67506
67507ET-23^ Mog 67514
67515150 E-17 Med. 67508
67509ET-231/: Mog 67516
67517BT-28 Mog 67518
200 ET-18 Mog 67576250 ET-18 Mog 67578
BT-28 Mog 67521310 ET-18 Mog 67580350 T-m Mog 67613400 ET-18 Mog 67533
BT-37 Mog 67524T-7 RSC 67527
430 T-14.5 Mog 67615600 T-16 Mog 67614
67616750 BT-37 Mog 675471000 E-25 Mog 67307
LU35/MEDLU35/D/MEDLU50/MEDLU50/D/MEDLU50LU50/DLU70/MEDLU70/D/MEDLU70LU70/DLU100/MEDLU100/D/MEDLU100LU100/DLU150/MEDLU150/D/MEDLU1 50/55LU150/55/DLU150/100LU200LU250LU250/DLU310
S76ZLS76ZLS68ZLS68ZLS68NVS68IWS62ZLS62ZLS62CXS62CXS54ZLS54ZLS54CXS54CXS55ZLS55ZLS55CXS55CXS56KAS66EJS50EJS50KAS67EJ
LU350 SUPER D N/ALU400LU400/DLU400T7RSC
S51EJS51ZC
S51LU430PLANTAD S51GJLU600 SUPER S106GCLU600PLANTAD S106GCLU750LU1000
S 1 1 1 Z CS52XB
20202020202020202020202020202020202010202010201020101010101066
ClearCoated6
ClearCoated6
ClearCoated6
ClearCoated6
ClearCoated6
ClearCoated6
ClearCoated6
Clear, 55 VoltCoated, 55 Volt6
Clear, 55 Volt7
Coated, 55 Volt6-7
Clear, 100 Volt7
ClearClearCoated6
ClearClearClearCoated6
ClearClearClearClearClear14
Clear14
16000+16000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+1800024000+24000+240001800018000180002400024000+
2250 20502100 19354000 36003700 34204000 36003700 34206300 53505800 49006300 55005800 49009500 80008800 75009500 80008800 750015800 1340014500 1230016000 1380014700 1250015700 1 4 1 0 022000 1980029000 2610026000 2340037000 3330046500 4400050000 4500047500 4230046000 4140051500 4240092000 8100084000 75000105000 94500130000 120700
37/63^6
3?/6
37/6
55
37/6
3?/6
55
37/6
3?/6
55
39/6
3'/6
555
53/5%5
5%5%5%15
6%6%6%6%8%
5'/6
514
5!45!4TkTA57/6
57/6
TATA57/6
5'/6
TATA5%5%TATA85/6
9%9%85A9%9M9%m10K6
m1 1 %m1 1 5 *1514
Energy Saving Product/Value Added Product I I High Color Rendering Lamp New Item Footnotes/Symbols pages 167-169
GUIDE TO HIGH PRESSURE SODIUM LAMPS
STEELFRAME
DOME MOUNT SUPPORT
ALUMINA ARC TUBE
WEATHER RESISTANTGLASS ENVELOPE
VACUUM
RESIDUE GAS GETTER
BRASS DATERECORDING BASE
There are currently four families of OSRAM SYLVANIA Products Inc. High 'Pressure Sodium lamps: LumaluxPlus™ Lumalux,® Lumalux® Standby andUnalux® They are one of the most efficient HID sources available. These lampsare used for general lighting applications where high efficiency and long life aredesired and color rendering is not critical. Typical applications include street-lighting, industrial hi-bay, parking lot lighting, and building floodlighting.
LUMALUX PLUS™/ECO™These environmentally friendlier lamps are designed with lead-free weldedmogul bases and they contain up to 90% less mercury than standard HPSlamps. They will NOT CYCLE at end of life. All lamps operate on existing HPSballasts for corresponding wattages. LUMALUX PLUS™ lamps pass the existingFederal TCLP limit (4/98).27
LUMALUX®Available in a broad range of mogul base general lighting lamps from 50-1000watts for universal operation. Lamps from 35 to 150 watts are also available inmedium base. Most lamps are available in clear and coated bulbs.
LUMALUX® STANDBYThese lamps are designed with two arc tubes to provide instant restrike capability in the event of a momentary power interruptionwithout total loss of light.UNALUX®These retrofit lamps are designed to operate on all mercury reactor ballasts when increased light and reduced energy is desired.
I WA™'"° I LUMALUX PLUS™, LUMALUX® AND LUMALUX® STANDBY LAMPS I »«""• I1. These lamps must be operated with a fixture and ballast which has an ANSI designation identical to the ANSI designation on the lamp etch on the outer glass bulb,otherwise the lamp may shatter resulting in the discharge of hot glass particles. SHOULD THIS OCCUR, THERE IS A RISK OF PERSONAL INJURY, PROPERTYDAMAGE, BURNS AND FIRE FROM HOT PARTICLES OR SHATTERED GLASS.2. Do not remove or insert lamps when power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled.3. Do not expose operating lamp to moisture. • I4. Replace the lamp if outer glass bulb has been scratched, cracked or damaged in any way.5. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.Operating and Installation Instructions1. To avoid burn injury, allow lamp to cool before removing from the fixture.2. To ensure electrical contact, screw lamp firmly but not forcibly into the socket. Excessive force may cauSe the outer glass bulb to break.3. Lamps may be operated in any position.4. For maximum system performance, replace lamp at or before end of published rated life.5. Lumalux19 lamps require a specially designed base socket electrically rated to withstand 4000 volt pulses except LU750 and LU1000 which require sockets to with-stand 5000 volt pulses. - _____ _____
I **"»""= | UNALUX® LAMPS I WAHN"IG IUnalux lamps will operate satisfactorily on conventional Mercury ballast circuits meeting current ANSI specifications. Ballast must be high leakage reactance lag typeauto-transformer; or a 240 or 277 volt reactor for the 150W, 215W, 360W lamps and a 480 volt reactor for the 880W lamp. Lamps should not be used in luminarieswhich cause excessive increase in arc tube operating voltage. Do not use these lamps with constant wattage or constant wattage auto-transformer ballasts,conventional high pressure sodium ballasts or equipment not meeting conditions shown in the following table.
ApproximateMercury ANSI Unalux Lamp
Lamp Wattage Ballast Unalux Type Wattage175 (H39) ULX-150250 (H37) ULX-215400 (H33) ULX-360
1000 (H36) ULX-880
150215360880
I """""M \ SOX® LAMPS I W*""INS I1. These lamps must be operated with a fixture and ballast which has an ANSI designation identical to the ANSI designation listed on
page 84 for the corresponding wattages.
• 2. Single based SOX lamps 35W to 180W should be supported traction-relief at the end opposite to the base.
3. SOX lamps contain a small quantity of sodium. In case of lamp breakage, the sodium may develop heat when in contact with moisture. Therefore, the lamp must bestored and shipped enclosed in its original package.
4. The following procedure should be applied when disposing of burned out lamps in order to avoid damage:
A. Place lamp in a dry, high container and break it into small pieces in the open air and in a dry atmosphere. B. Fill the container with water by means of a rubber hose,the operator standing at a safe distance. C. After a few minutes, the sodium will be rendered harmless due to the effect of the water. D. Care should be taken that novarnished parts (for instance an automobile) are in the neighborhood which might be attacked by the sodium hydrate or splashes of sodium hydrate, respectively.