IIndustrialndustrialLINAC at NDT laboratory LINAC at NDT … · 2014-05-20 ·...
Embed Size (px)
Transcript of IIndustrialndustrialLINAC at NDT laboratory LINAC at NDT … · 2014-05-20 ·...

IIndustrialndustrial LINAC at NDT laboratory LINAC at NDT laboratory and its potential applicationsand its potential applicationsand its potential applicationsand its potential applications
PIOTR WILKPIOTR WILKWROCŁAW TECHNOLOGY PARKWROCŁAW TECHNOLOGY PARK
1

InfrastructureInfrastructureLambdaLambda buildingbuilding
BunkerBunker (radiation(radiation protection)protection)
AcceleratorAccelerator::AcceleratorAccelerator::PrinciplePrinciple ofof operatingoperatingBeamBeam parametersparametersManipulatorsManipulators
AppApplicationslicationsRadiographyRadiography
SemiconductorsSemiconductorsSemiconductorsSemiconductorsGemstonesGemstonesPolymersPolymersUtilizationUtilization,, sterylizationsterylization
FutureFuture plansplansTomographyTomography,, electronelectron beembeem applicatorsapplicators
2

Lambda Lambda BuildingBuilding
3

BunkerBunker
DARK ROOM
CORRIDOR
CONTROL ROOM
ELECTRONIC MONITORINGSYSTEM
VOICE CONTACT SYSTEM
SAFETY SWITCHES
FORK-LIFT TRUCKOBJECT
MANIPULATOR
INDUSTRIALACCELERATOR
STATION
MEDICALACCELERATOR
STATION
ACCELERATOR
CONCRETE DOORS
LABYRINTHRELOADING ROOM
PAR
KIN
G
FORK-LIFT TRUCKMANIPULATOR
DETECTORMANIPULATOR
CONVEYOR BELTGANTRY CRANE
ACCESS ROAD 4

Industrial Industrial acceleratoraccelerator stationstation
Produced by National Centre for Nuclear Research - Świerk5

PrinciplePrinciple of of operatingoperating
REFLECTED WAVECOUPLER
INCIDENT WAVE
COUPLER
WATER LOAD
TUNINGMECHANISM
MO
DU
LATO
RS
STANDING WAVE ACCELERATING
STRUCTURE
TARGET
IONIZATIONCHAMBER
COUPLER
MICROWAVEISOLATOR
CIRCULATOR
MAGNETRON
MECHANISM
MICROWAVEWINDOW
SOLIDCOLLIMATOR
RADIATIONCONE
MO
DU
LATO
RS
STRUCTURE
ELECTRON GUN
VACUUM PUMP
SOLENOID FOCUSING COILS
DUBLET COILS
FLATERINGFILTER
SUP
PLY
SUPPLY
CONE
6

ParametersParametersX-RAY BEAM ENERGY dual: 6 or 9 MV
X-RAY BEAM DOSE RATE max. 20 Gy/min for 9 MeVat the distance 1 m from target
RADIATION STABILITY ≤≤≤≤ 2% during the period of 8 hours
X-RAY BEAM ASYMMETRY ±±±± 5%
RADIOGRAPHIC QUALITY 1-2T or better
FOCAL SPOT SIZE 2 mm
RADIATION LEAKAGE ≤≤≤≤ 0,1 %
X-RAY BEAM FLATNESS better than 10%within 80% of beam width around
radiation axis
HALF-VALUE LAYER (9 MV) 30,0 mm for STEEL15,2 mm for LEAD
PRIMARY COLLIMATOR CONE 28°°°°IRRADIATION FIELD DIAMETER 50 cm
in the plane located 1 m from the target
7

ManipulatorsManipulatorsAccelerator (2 axes)
Vertical: Z = 1,5 mTilting: αααα: ±±±± 22,5°°°°
Object (3 axes)Horizontal: X,Y = 1 m
Rotating: 360 °°°°Load: 5 tons
Detector (2 axes)Vertical: Z = 1,5 m
Horizontal: X = 0,6 m
`
8

RadiographyRadiography
Radiography - imaging technique
Certain amount of photons is absorbedby the object.by the object.
Detector (film) illustrates the internalstructure (density distribution).
Subject of studies are:castings, bridges spans, cointainersand welds
9

Workshop on Radiation Effects Workshop on Radiation Effects in in Superconducting Superconducting Magnets and Materials 2014 Magnets and Materials 2014
RadiographyRadiography::
Point
Source
Object
Detecting
Plane
Object
10

Workshop on Radiation Effects Workshop on Radiation Effects in in Superconducting Superconducting Magnets and Materials 2014 Magnets and Materials 2014
RadiographyRadiography
Object
Point
Source
Object
Detecting
Plane
X- Ray Film X- Ray Film
Density Plot
11

Workshop on Radiation Effects Workshop on Radiation Effects in in Superconducting Superconducting Magnets and Materials 2014 Magnets and Materials 2014
RadiographyRadiography
Object
Point
Source
Detecting
Plane
X- Ray Film X- Ray Film
Density Plot
12

RadiographyRadiography
Object
Real
Source
Detecting
Plane
X- Ray Film X- Ray Film
Density Plot
13

RadiographyRadiography
Object
Real
Source
Object
Detecting
Plane
X- Ray Film X- Ray Film
Density Plot
14

Workshop on Radiation Effects Workshop on Radiation Effects in in Superconducting Superconducting Magnets and Materials 2014 Magnets and Materials 2014
RadiographyRadiography
Object
Point
Source
Object
Detecting
Plane
X- Ray Film X- Ray Film
Density Plot
15

1,0E+18
1,0E+20
mu
ltip
licyt
yIo
/I d = 100 cm
d = 50 cm
d = 25 cm
I0 /I = exp[(µ/ρ)µ/ρ)µ/ρ)µ/ρ)d]
RadiographyRadiography
1,0E+06
1,0E+08
1,0E+10
1,0E+12
1,0E+14
1,0E+16
Att
en
uat
ion
mu
ltip
licyt
y
d = 25 cm
d = 15 cm
d = 10 cm
d = 5 cm
d = 2 cm
d = 1 cm
1,0E+00
1,0E+02
1,0E+04
1,0E+06
0,0625 0,125 0,25 0,5 1 2 4 8 16 32
Energy [MeV]
16

ElectronicsElectronics
Diodes or transistors after beeing irradiated with electrons
improve their switching speed improve their switching speed
(But it can be recovered by annealing)
Advantages:
Switching speed increases
Also finished products can be irradiatedAlso finished products can be irradiated
17

Gemstones irradiated with electrons change their color
Examples
Diamond Quartz
JewelleryJewellery
Diamond Quartz
BROWN AMETHYST ROSEGREEN BLUE
18

PolymersPolymers
Scissioning
Radiation can influnce the structure of polymers
Cross-linking
G(X)G(S)
Three-dimensionallinks between
adjacentpolymer chains
G(X)G(S)
19

PolymersPolymers
Grafting
Radiation can influnce the structure of polymers
Low molecularpolymer
Backbone polymer chain
polymer
High molecularpolymer
20

PolymersPolymersInsulation jacketing (wires)
Resistant to fire and short circuit
Resistant to chemical solvents
Higher tensile strength
The use of volatile organic coumpounds is not neccessary
Curring of ink or coatings
Higher tensile strength
Tires vulcanisation
Degradation
Teflon to produce powdersTeflon to produce powders
Cellulose to produce viscose
Ion selective membranes
Heat-shrinkable tubes and foils
21

SterylizationSterylization
Medical instruments dezinfection
Waste water treatment
(Salmonella and E. coli)Scissioning the DNA of patogens
Medical instruments dezinfection
Food Food conservationconservationKills patogens and insects
Sprout inhibiting
Delay of ripening
EnviromentEnviroment
Flue gas treatment - high efficiency of SOx NOx removalBy pass product is fertilizer
22

FutureFuture plansplans
Tomography
Electron beam applicators
Extra equipment for NDT laboratory
Material science laboratory
Utrasonic defectoscope
Videoendoscope
23
Maybe magnet
Micro-CT, SEM, XRDChemical analyserHardness testersServohydraulic fatigue machines

24