igus Measuring cables

13
Selection chart for chainflex ® measuring system cables 162 CF211 PVC 10 -5/ +70 5 3 50 164 CF111.D PUR 12 -35/ +100 2 30 170 CF113.D PUR 10 -20/ +80 5 3 50 174 CF11.D TPE 10 -35/ +100 10 6 100 180 Measuring system cables chainflex ® cable Jacket Shield Temperature, moved from/to [°C] Approvals and standards Min. bending radius, moved [factor x d] Oiil-resistant Torsion resistant v max. [m/s] unsupported v max. [m/s] gliding a max. [m/s 2 ] Page Measuring system cables chainflex ® type 161

description

This catalogue gives an overview and technical data of measuring cables range. Chainflex measuring system cables are for medium to high stressing. The measuring system cables can be used in high speeds and accelerations and comply with the specifications of the drive systems manufacturers.For more information see http://www.igus.co.uk/wpck/default.aspx?PageNr=2205&CL=GB-en&c=gb&L=en&wt.mc_id=SCRUK

Transcript of igus Measuring cables

Page 1: igus Measuring cables

Selection chart for chainflex® measuring system cables 162

CF211 PVC � 10 -5/ +70 � 5 3 50 164

CF111.D PUR � 12 -35/ +100 � 2 30 170

CF113.D PUR � 10 -20/ +80 � 5 3 50 174

CF11.D TPE � 10 -35/ +100 � 10 6 100 180

Mea

surin

g sy

stem

cab

les

chai

nfle

cab

le

Jack

et

Shi

eld

Tem

per

atur

e,m

ove

d

fro

m/t

o [°

C]

Ap

pro

vals

an

d s

tand

ard

s

Min

. ben

din

gra

diu

s, m

ove

d[f

acto

rx

d]

Oiil

-res

ista

nt

Tors

ion

resi

stan

t

v m

ax. [

m/s

]un

sup

po

rted

v m

ax. [

m/s

] g

lidin

g

a m

ax. [

m/s

2 ]

Pag

e

Measuring system cables

chainflex® type

161

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 160

Page 2: igus Measuring cables

162

B&RCFxxx.027.D (5x(2x0,14)+2x0,5)C � � � �

BaumüllerCFxxx.027.D (5x(2x0,14)+2x0,5)C � � � �

Berger LahrCFxxx.011.D (4x(2x0,34)+4x0,5)C � � � �

Control TechniquesCFxxx.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C � � � �

CFxxx.011.D (4x(2x0,34)+4x0,5)C � � � �

ELAUCFxxx.009.D (4x(2x0,25)+2x0,5)C � � �

FagorCFxxx.004.D (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C � � �

CFxxx.015.D (4x(2x0,14)+4x0,5)C � � �

FANUCCFxxx.021.D (3x(2x0,5+2x0,25)+(4x0,25))C � � �

CFxxx.022.D (5x0,5+(2x0,25))C � � �

HeidenhainCFxxx.004.D (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C � � �

CFxxx.005.D (4x(2x0,14)+4x0,5)C � �

CFxxx.015.D (4x(2x0,14)+4x0,5)C � � �

CFxxx.025.D (3x(2x0,14)C+(2x0,5)C)C � �

JetterCFxxx.002.D (3x(2x0,14)C+(2x0,5C))C � � �

CFxxx.025.D (3x(2x0,14)C+(2x0,5)C)C � �

LenzeCFxxx.002.D (3x(2x0,14)C+2x(0,5)C)C � � �

CFxxx.010.D (4x(2x0,25)+2x1,0)C � � �

CFxxx.025.D (3x(2x0,14)C+(2x0,5)C)C � �

CFxxx.032.D 3x(2x0,14)C+(3x0,14)C � �

CFxxx.033.D 4x(2x0,14)C+2x(1,0)C � �

CFxxx.034.D 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C � �

LTi DRiVESCFxxx.004.D (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C � � �

CFxxx.009.D (4x(2x0,25)+2x0,5)C � � �

CFxxx.010.D (4x(2x0,25)+2x1,0)C � � �

Drive TechnologySystem

Number of cores andconductor nominalcross section [mm2]

CF211.yyy5.3.2PVC164

chainflex®-seriesClass

JacketPage

CF111.yyy.D4.1.3PUR170

CF113.yyy.D6.3.3PUR174

CF11.yyy.D6.4.4TPE180

NUMCFxxx.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C � � � �

OmronCFxxx.008.D (3x(2x0,25))C � �

CFxxx.009.D (4x(2x0,25)+2x0,5)C � � �

CFxxx.010.D (4x(2x0,25)+2x1,0)C � � �

CFxxx.018.D (2x(2x0,25)+2x0,5)C � � �

RexrothCFxxx.009.D (4x(2x0,25)+2x0,5)C � � �

CFxxx.010.D (4x(2x0,25)+2x1,0)C � � �

CFxxx.017.D (4x(2x0,14)+(4x0,14)C+4x1,0)C � � �

CFxxx.018.D (2x(2x0,25)+2x0,5)C � � �

CFxxx.019.D (3x(2x0,25)C+(3x0,25)+2x1,0)C � � �

SEWCFxxx.009.D (4x(2x0,25)+2x0,5)C � � �

SiemensCFxxx.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C � � � �

CFxxx.002.D (3x(2x0,14)C+2x(0,5)C)C � � �

CFxxx.006.D (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C � � � �

CFxxx.011.D (4x(2x0,34)+4x0,5)C � � � �

CFxxx.028.D (2x(2x0,15)+(2x0,38))C �

StöberCFxxx.008.D (3x(2x0,25))C � �

CFxxx.009.D (4x(2x0,25)+2x0,5)C � � �

CFxxx.011.D (4x(2x0,34)+4x0,5)C � � � �

CFxxx.016.D (3x(2x0,25)C)C � � �

CFxxx.021.D (3x(2x0,5+2x0,25)+(4x0,25))C � � �

Altri cavi chainflex®

CFxxx.003.D (3x(2x0,14)+2x1,0)C � �

CFxxx.007.D (2x2x0,34)C � �

CFxxx.012.D (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C � �

CFxxx.013.D (3x(2x0,14)C+2x0,5)C � �

CFxxx.014.D (4x(2x0,25)C+2x0,5)C � � �

CFxxx.035.D (4x(2x0,25)C+2x(2x0,5))C �

Selection chart for chainflex® measuring system cables

163

chainflex®

Measuringsystemcables

chainflex®

Measuringsystemcables

Drive TechnologySystem

Number of cores andconductor nominalcross section [mm2]

CF211.yyy5.3.2PVC164

chainflex®-seriesClass

JacketPage

CF111.yyy.D4.1.3PUR170

CF113.yyy.D6.3.3PUR174

CF11.yyy.D6.4.4TPE180

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 162

Page 3: igus Measuring cables

Conductor Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.

Core insulation Mechanically high-quality PP mixture.

Core stranding According to measuring system specification.

Core identification According to measuring system specification Schedule Delivery Program

Element shield Extremely bending-resistant, tinned copper cover. Coverage approx. 90% optical.

Element jacket TPE mixture adapted to suit the requirements in energy chains®

over pair shield.Intermediate jacket Foil taping over the external layer.

Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion, oil-resistant mixture on the basis of PVC, adap-ted to suit the requirements in energy chains® (following DIN VDE0281 Part 13). Colour: Silver gray (similar to RAL 7001)Colour: Yellow green (similar to RAL 6018) – starting from manu-facturing date 5/2012

T/R moved -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2.+5 °C to +70 °C for use in energy chains® with > 50.000 cycles.Minimum bending radius 10 x d.

T/R fixed -20 °C to +70 °C, minimum bending radius 5 x d

v max. 5 m/s, 3 m/sunsupported/glidinga max. 50 m/s2

Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3

Nominal voltage 30 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 50363-4-1), Class 2.

PVC Measuring system cable CF211 Class 5.3.2 (5 high load requirements 3 travel distance up to 100 m 2 oil-resistant)

� for high load requirements� PVC outer jacket� shielded� oil-resistant� flame-retardant

eplan download, configurator www.igus.eu/en/CF211MThree energy chain systems® in several axes fitted with specially cables from igus®. e-chain®: System E4/00and System E4/0

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 1589 and 2502, 30 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI Following CEI 20-35

CE Following 2006/95/EG

Lead free Following 2011/55/EU (RoHS-II)

Clean room According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPAaccording to standard 14644-1.

Typical application area

� for high load requirements� light oil influence� preferably indoor applications, but also outdoor ones at temperatures > 5 °C� especially for freely suspended and gliding travel distances up to 100 m� Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes,

wood/stone processing

165

CF211PVC

10 x d

CF211PVC

10 x d

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)Im

age

exem

pla

ry.

Phas

e-ou

tm

odel

NEW!Outer jacket in green

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 164

Page 4: igus Measuring cables

CF211.001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0 61 100

CF211.002 (3x(2x0,14)C+2x(0,5)C)C 9,0 63 110

CF211.006 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5 72 120

CF211.009 (4x(2x0,25)+2x0,5)C 9,0 51 111

CF211.010 (4x(2x0,25)+2x1,0)C 9,5 74 141

CF211.011 (4x(2x0,34)+4x0,5)C 9,0 75 135

CF211.014 (4x(2x0,25)C+1x2x0,5)C 13,0 84 211

CF211.016 (3x(2x0,25)C)C 11,0 85 170CF211.017 (4x(2x0,14)+4x1,0+(4x0,14)C)C 9,0 85 124

CF211.018 (2x(2x0,25)+2x0,5)C 7,0 41 62

CF211.019 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0 82 115

Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Delivery programPart No.

Number of cores andconductor nominal crosssection [mm2]

External diameterapprox. [mm]

Copperindex[kg/km]

Weight[kg/km]

Image exemplary.

Class 5.3.2 (5 high load requirements 3 travel distance up to 100 m 2 oil-resistant)PVC Measuring system cable CF211

166

CF211.001 3x(2x0,14)C green/yellow, black/brown, red/orange4x0,14 gray, blue, white-yellow, white-black2x0,5 brown-red, brown-blue

CF211.002 3x(2x0,14)C green/yellow, black/brown, red/orange2x(0,5)C black, red

CF211.006 3x(2x0,14)C green/yellow, black/brown, red/orange4x0,14 gray, blue, white-yellow, white-black4x0,23 brown-yellow, brown-gray, green-black, green-red2x0,5 brown-red, brown-blue

CF211.009 4x(2x0,25) brown/green, blue/violet, gray/pink, red/black2x0,5 white, brown

CF211.010 4x(2x0,25) brown/green, blue/violet, gray/pink, red/black2x1,0 white, brown

CF211.011 4x(2x0,34) black/brown, red/orange, yellow/green, blue/violet4x0,5 blue-white, black-white, red-white, yellow-white

CF211.014 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red2x0,5 black (numeral printing 1-2)

CF211.016 3x(2x0,25)C white/brown, green/yellow, gray/pinkCF211.017 (4x0,14)C blue-black, red-black, yellow-black, green-black

4x(2x0,14) red/black, green/brown, yellow/violet, pink/gray4x1,0 white-green, brown-green, blue, white

CF211.018 2x(2x0,25) red/black, gray/pink2x0,5 white, brown

CF211.019 3x(2x0,25)C brown/green, pink/gray, red/black(3x0,25) blue, yellow, violet(2x1,0) white, brown

Delivery programPart No.

Core group Colour code

167

CF211PVC

10 x d

CF211PVC

10 x d

eplan download, configurator www.igus.eu/en/CF211M

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

Other types Page 168

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 166

Page 5: igus Measuring cables

CF211.020(1) (3x(2x0,14)+2x(4x0,14)+(2x0,5)C)C 8,5 90 103

CF211.022 (5x0,5+1x2x0,25)C 7,0 50 84

CF211.027 (5x(2x0,14)+2x0,5)C 9,0 45 102

CF211.028 (2x(2x0,15)+2x0,38)C 7,0 45 69

CF211.038(1) (3x(2x0,14)+2x0,5) 8,0 44 94

(1) Delivery time upon inquiry.Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core* New in this catalogue.

Delivery programPart No.

Number of cores andconductor nominal crosssection [mm2]

External diameterapprox. [mm]

Copperindex[kg/km]

Weight[kg/km]

Image exemplary.

Class 5.3.2 (5 high load requirements 3 travel distance up to 100 m 2 oil-resistant)PVC Measuring system cable CF211

168

CF211.020(1) 3x(2x0,14) red/blue, black/violet, gray-pink/red-blue2x(4x0,14) green/gray/yellow/pink, white-green/white-yellow/brown-green/brown-yellow

(2x0,5) white/brownCF211.022(1) 5x0,5 blue, green, yellow, gray, pink

2x025 white, brownCF211.027 5x(2x0,14) green/brown, gray/yellow, white/violet, black/red, blue/pink

(2x0,5) white-green, white-redCF211.028(1) (2x(2x0,15) green/yellow, pink/blue

2x0,38 red, blackCF211.038(1) 3x(2x0,14) white/brown, green/yellow, gray/pink

2x0,34 blue/red

Delivery programPart No.

Core group Colour code

Order example: CF211.001 – in your desired length (0,5 m steps)CF211 chainflex® series .001 Code Measuring system

Please use www.chainflex.eu/en/CF211M for your online order.

Delivery time 24h or today.Delivery time means time until shipping of goods.

New*

New*

New*

New*

New*

169

CF211PVC

10 x d

CF211PVC

10 x d

eplan download, configurator www.igus.eu/en/CF211M

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

Other types Page 166

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:57 Seite 168

Page 6: igus Measuring cables

Conductor Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.

Core insulation Mechanically high-quality PP mixture.

Core stranding According to measuring system specification.

Core identification According to measuring system specification Schedule Delivery Program

Element shield Extremely bending-resistant, tinned copper cover. Coverage approx. 90% optical.

Intermediate jacket Foil taping over the external layer.

Overall shield Bending-resistant braiding made of tinned copper wires.Coverage approx. 55% linear, approx. 80% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains®

(following DIN VDE 0282 Part 10) – starting from manufacturingdate 5/2012. Colour: Yellow green (similar to RAL 6018)

T/R moved -20 °C to +80 °C, minimum bending radius 12 x d

T/R fixed -40 °C to +100 °C, minimum bending radius 6 x d

v max. 2 m/sfreely suspendeda max. 30 m/s2

Travel distance Freely suspended travel distances, Class 1

UV-resistant Medium

Nominal voltage 30 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 – status 2009.

PUR Measuring system cable CF111.D Class 4.1.3 (4 medium load requirements 1 freely suspended 3 oil-resistant)

� for medium load requirements� PUR outer jacket� shielded� oil-resistant and coolant-resistant� notch-resistant� flame-retardant� hydrolysis-resistant and microbe-resistant� PVC-free/halogen-free

Imag

e ex

emp

lary

. eplan download, configurator www.igus.eu/en/CF111DThe readychain® systems from igus® are completely pre-harnessed with chainflex® cables, hoses, screwattachments, metal parts etc.

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 1589 and 21371, 30 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI Following CEI 20-35

CE Following 2006/95/EG

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/55/EU (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D,tested by IPA according to standard 14644-1

Typical application area

� for medium load requirements� almost unlimited resistance to oil � indoor and outdoor applications without direct sun radiation� especially for freely suspended travel distances� Machining units/machine tools, low temperature applications

171

CF111.DPUR

12 x d

CF111.DPUR

12 x d

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

NEW!Outer jacket in PUR

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 170

Page 7: igus Measuring cables

CF111.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C 8,5 56 87

CF111.004.D (4x(2x0,14)+(4x0,14)C+4x0,5)C 10,5 72 113

CF111.006.D (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 10,0 69 112

CF111.011.D (4x(2x0,34)+4x0,5)C 9,5 69 106

CF111.015.D (4x(2x0,14)+4x0,5)C 8,0 49 76

CF111.020.D(1) (3x(2x0,14)+2x(4x0,14)+(2x0,5)C)C 8,5 90 93

CF111.021.D (6x0,5+5x2x0,25)C 10,0 79 125

CF111.022.D (5x0,5+1x2x0,25)C 8,0 49 78

CF111.027.D (5x(2x0,14)+2x0,5)C 9,0 54 109

CF111.028.D (2x(2x0,15)+2x0,38))C 7,0 45 69

CF111.035.D (4x(2x0,25)C+2x(2x0,5))C 12,5 118 202

(1) Delivery time upon inquiry.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core* New in this catalog.

Delivery programPart No.

Number of cores andconductor nominal crosssection [mm2]

External diameterapprox. [mm]

Copperindex[kg/km]

Weight[kg/km]

Image exemplary.

Class 4.1.3 (4 medium load requirements 1 freely suspended 3 oil-resistant)PUR Measuring system cable CF111.D

172

CF111.001.D 3x(2x0,14)C green/yellow, black/brown, red/orange4x0,14 gray, blue, white-yellow, white-black2x0,5 brown-red, brown-blue

CF111.004.D 4x(2x0,14) brown/green, violet/yellow, gray/pink, red/black(4x0,14)C yellow-black, red-black, green-black, blue-black

4x0,5 brown-green, white-green, blue, whiteCF111.006.D 3x(2x0,14)C green/yellow, black/brown, red/orange

4x0,14 gray, blue, white-yellow, white-black4x0,23 brown-yellow, brown-gray, green-black, green-red2x0,5 brown-red, brown-blue

CF111.011.D 4x(2x0,34) black/brown, red/orange, yellow/green, blue/violet4x0,5 blue-white, black-white, red-white, yellow-white

CF111.015.D 4x(2x0,14) brown/green, violet/yellow, gray/pink, red/black4x0,5 blue, white, brown-green, white-green

CF111.020.D(1) 3x(2x0,14) red/blue, black/violet, gray-pink/red-blue2x(4x0,14) green/gray/yellow/pink, white-green/white-yellow/brown-green/brown-yellow

(2x0,5) white/brownCF111.021.D (3x0,5) black (numeral printing 1-3)

(3x0,5) red (numeral printing 1-3)(5x2x0,25) yellow/white, gray/white, black/orange, white/brown, black/gray

CF111.022.D (5x0,5) blue, green, yellow, gray, pink(2x0,25) white, brown

CF111.027.D(1) 5x(2x0,14) green/brown, gray/yellow, white/violet, black/red, blue/pink(2x0,5) white-green, white-red

CF111.028.D (2x(2x0,15) green/yellow, pink/blue2x0,38 red, black

CF111.035.D 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red2x(2x0,5) black (numeral printing 1-4)

Delivery programPart No.

Core group Colour code

Order example: CF111.021.D – in your desired length (0,5 m steps)CF111.D chainflex® series .021 Code Measuring system

Please use www.chainflex.eu/en/CF111D for your online order.

Delivery time 24h or today.Delivery time means time until shipping of goods.

New*

New*

173

CF111.DPUR

12 x d

CF111.DPUR

12 x d

eplan download, configurator www.igus.eu/en/CF111D

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 172

Page 8: igus Measuring cables

Conductor Fine-wire stranded conductor in especially bending-resistantversion consisting of tinned copper wires (following EN 60228).

Core insulation Mechanically high-quality PP mixture.

Core stranding According to measuring system specification.

Core identification According to measuring system specification Schedule Delivery Program

Element shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.

Inner jacket TPE mixture adapted to suit the requirements in energy chains®.

Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains®

(following DIN VDE 0282 Part 10). Colour: Yellow-green (similar to RAL 6018)

T/R moved -20 °C to +80 °C, minimum bending radius 10 x d

T/R fixed -40 °C to +80 °C, minimum bending radius 5 x d

v max. 5 m/s, 3 m/sunsupported/glidinga max. 50 m/s2

Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3

UV-resistant Medium

Nominal voltage 30 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore MUD-resistant following NEK 606 – status 2009.

PUR Measuring system cable CF113.D Class 6.3.3 (6 maximum load requirements 3 travel distance up to 100 m 3 oil-resistant)

� for maximum load requirements� PUR outer jacket� shielded� oil-resistant and coolant-resistant� notch-resistant� flame-retardant� hydrolysis-resistant and microbe-resistant� PVC-free/halogen-free

Imag

e ex

emp

lary

. eplan download, configurator www.igus.eu/en/CF113D chainflex® measuring system cable in a double-spindle horizontal machining centre.

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Halogen-free Following EN 50267-2-1.

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 1589 and 20236, 30 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI Following CEI 20-35

CE Following 2006/95/EG

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/55/EU (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D,tested by IPA according to standard 14644-1

Typical application area

� for maximum load requirements� almost unlimited resistance to oil� indoor and outdoor applications without direct sun radiation� especially for freely suspended and gliding travel distances up to 100 m� Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,

semiconductor insertion, indoor cranes, low-temperature applications

175

CF113.DPUR

10 x d

CF113.DPUR

10 x d

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 174

Page 9: igus Measuring cables

CF113.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5 72 172

CF113.002.D (3x(2x0,14)C+2x(0,5)C)C 10,5 74 185

CF113.003.D(1) (3x(2x0,14)+2x1,0)C 8,5 55 124

CF113.004.D (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 11,5 82 195

CF113.005.D (4x(2x0,14)+4x0,5)C 9,5 61 144

CF113.006.D (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,0 84 197

CF113.007.D(2) (2x2x0,34)C 6,0 29 64CF113.008.D (3x(2x0,25))C 8,0 33 81CF113.009.D (4x(2x0,25)+2x0,5)C 9,5 60 137

CF113.010.D(1) (4x(2x0,25)+2x1,0)C 9,5 72 159

CF113.011.D(1) (4x(2x0,34)+4x0,5)C 10,5 87 199

CF113.012.D(1) (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 11,5 90 220

CF113.013.D(1) (3x(2x0,14)C+2x0,5)C 9,5 63 153

CF113.014.D(1) (4x(2x0,25)C+2x0,5)C 11,5 86 210

CF113.015.D (4x(2x0,14)+4x0,5)C 9,5 61 140

CF113.016.D (3x(2x0,25)C)C 9,5 59 141

(1) Delivery time upon inquiry.Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Delivery programPart No.

Number of cores andconductor nominal crosssection [mm2]

External diameterapprox. [mm]

Copperindex[kg/km]

Weight[kg/km]

Image exemplary.

Class 6.3.3 (6 maximum load requirements 3 travel distance up to 100 m 3 oil-resistant)PUR Measuring system cable CF113.D

176

CF113.001.D 3x(2x0,14)C green/yellow, black/brown, red/orange(4x0,14) gray, blue, white-yellow, white-black(2x0,5) brown-red, brown-blue

CF113.002.D 3x(2x0,14)C green/yellow, black/brown, red/orange2x(0,5)C black, red

CF113.003.D(1) 3x(2x0,14) white/brown, green/yellow, gray/pink2x1,0 blue, red

CF113.004.D 2x(2x2x0,14) brown/green, violet/yellow, gray/pink, red/black(4x0,14)C yellow-black, red-black, green-black, blue-black

4x0,5 brown-green, white-green, blue, whiteCF113.005.D 4x(2x0,14) white/brown, green/yellow, gray/pink, blue/red

4x0,5 black, violet, gray-pink, red-blueCF113.006.D 3x(2x0,14)C green/yellow, brown/black, red/orange

(4x0,14) blue, gray, white-black, white-yellow(4x0,23) brown-yellow, brown-gray, green-black, green-red(2x0,5) brown-red, brown-blue

CF113.007.D 4x0,34 white, green, brown, yellow (star-quad stranding)CF113.008.D 3x(2x0,25) white/brown, green/yellow, gray/pinkCF113.009.D 4x(2x0,25) brown/green, blue/violet, gray/pink, red/black

2x0,5 white, brownCF113.010.D(1) 4x(2x0,25) brown/green, blue/violet, gray/pink, red/black

2x1,0 white, brownCF113.011.D(1) 4x(2x0,34) black/brown, red/orange, yellow/green, blue/violet

4x0,5 blue-white, black-white, red-white, yellow-whiteCF113.012.D(1) 3x(2x0,14)C green/yellow, white/gray, blue/red

(3x0,14)C red, green, brown6x0,14 blue, gray, gray, yellow, pink, violet2x0,5 brown-red, brown-blue

CF113.013.D(1) 3x(2x0,14)C white/brown, green/yellow, gray/pink2x0,5 red, blue

CF113.014.D(1) 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red2x0,5 black (numeral printing 1-2)

CF113.015.D 4x(2x0,14) brown/green, violet/yellow, gray/pink, red/black4x0,5 blue, white, brown-green, white-green

CF113.016.D 3x(2x0,25)C white/brown, green/yellow, gray/pink

Delivery programPart No.

Core group Colour code

Other types Page 178

177

CF113.DPUR

10 x d

CF113.DPUR

10 x d

eplan download, configurator www.igus.eu/en/CF113D

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 176

Page 10: igus Measuring cables

CF113.017.D(1)/(4) (4x(2x0,14)+(4x0,14)C+4x1,0)C 11,5 105 241

CF113.018.D(1)/(4) (2x(2x0,25)+2x0,5)C 9,0 38 114

CF113.019.D(1)/(4) (3x(2x0,25)C+(3x0,25)+2x1,0)C 11,5 96 225

CF113.021.D(1) (3x(2x0,5+2x0,25)+(4x0,25))C 11,0 92 210

CF113.022.D(1) (5x0,5+(2x0,25))C 8,5 50 121

CF113.025.D(1) (3x(2x0,14)C+(2x0,5)C)C 11,0 73 180

CF113.027.D(1) (5x(2x0,14)+2x0,5)C 9,0 52 121

CF113.028.D(4) (2x(2x0,15)+(2x0,38))C 7,5 47 72

CF113.032.D(1)/(15) 3x(2x0,14)C+(3x0,14)C 8,0 61 148

CF113.033.D(1)/(15) 4x(2x0,14)C+2x(1,0)C 10,0 97 237

CF113.034.D(1)/(15) 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 11,5 105 199

CF113.036.D (5x2x0,25)C 9,5 53 94CF113.037.D (6x2x0,25)C 10,0 60 106

CF113.038.D (3x2x0,14+1x2x0,34)C 7,5 36 67

(1) Delivery time upon inquiry.(4) manufactured without inner jacket.(15) manufactured without overall shieldOther types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core * New in this catalogue.

Delivery programPart No.

Number of cores andconductor nominal crosssection [mm2]

External diameterapprox. [mm]

Copperindex[kg/km]

Weight[kg/km]

Image exemplary.

Class 6.3.3 (6 maximum load requirements 3 travel distance up to 100 m 3 oil-resistant)PUR Measuring system cable CF113.D

178

CF113.017.D(1)/(4) 4x(2x0,14) red/black, green/brown, yellow/violet, pink/gray(4x0,14)C blue-black, red-black, yellow-black, green-black

4x1,0 white-green, brown-green, blue, whiteCF113.018.D(1)/(4) 2x(2x0,25) red/black, gray/pink

2x0,5 white, brownCF113.019.D(1)/(4) 3x(2x0,25)C brown/green, gray/pink, red/black

(3x0,25) blue, yellow, violet2x1,0 white, brown

CF113.021.D(1) 3x(2x0,25) white/yellow, white/gray, black/orange3x(2x0,5) black (numeral printing 1-6)(4x0,25) white, gray, brown, black

CF113.022.D(1) 5x0,5 blue, green, yellow, gray, pink(2x0,25) white, brown

CF113.025.D(1) 3x(2x0,14) green/yellow, blue/red, gray/pink(2x0,5)C white, brown

CF113.027.D(1) 5x(2x0,14) green/brown, gray/yellow, white/violet, black/red, blue/pink2x0,5 white-green, white-red

CF113.028.D(4) 2x(2x0,15) green/yellow, pink/blue(2x0,38) red, black

CF113.032.D(1)/(15) 3x(2x0,14)C yellow/black, red/black, green/black(3x0,14)C black, gray, pink

CF113.033.D(1)/(15) 4x(2x0,14)C yellow/black, red/black, green/black, blue/black2x(1,0)C white, brown

CF113.034.D(1)/(15) 3x(2x0,14)C green/black, violet/black, blue/black(4x0,14)C yellow, red-black, yellow-black, red

2x(2x0,5)C black/brown, black/whiteCF113.036.D 5x2x0,25 white/brown, green/yellow, gray/pink, blue/red, black/violetCF113.037.D 6x2x0,25 white/brown, green/yellow, gray/pink, blue/red, black/violet,

gray-pink/red-blueCF113.038.D 3x2x0,14 white/brown, green/yellow, gray/pink

1x2x0,34 blue/red

Delivery programPart No.

Core group Colour code

Order example: CF113.027.D – in your desired length (0,5 m steps)CF113.D chainflex® series .027 Code Measuring system

Please use www.chainflex.eu/en/CF113D for your online order.

Delivery time 24h or today.Delivery time means time until shipping of goods.

New*

New*

New*

179

CF113.DPUR

10 x d

CF113.DPUR

10 x d

Other types Page 176

eplan download, configurator www.igus.eu/en/CF113D

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 178

Page 11: igus Measuring cables

Conductor Fine-wire stranded conductor in especially bending-resistantversion consisting of tinned copper wires (following EN 60228).

Core insulation Mechanically high-quality PP mixture.

Core stranding According to measuring system specification.

Core identification According to measuring system specification Schedule Delivery Program

Element shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.

Inner jacket TPE mixture adapted to suit the requirements in energy chains®.

Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Yellow-green (similar to RAL 6018)

T/R moved -35 °C to +100 °C, minimum bending radius 10 x d

T/R fixed -40 °C to +100 °C, minimum bending radius 5 x d

v max. 10 m/s, 6 m/sunsupported/glidinga max. 100 m/s2

Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4

UV-resistant Medium

Nominal voltage 30 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

TPE Measuring system cable CF11.D Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)

� for maximum load requirements� TPE outer jacket� shielded� oil-resistant� biooil-resistant� PVC-free/halogen-free� hydrolysis-resistant and microbe-resistant

Imag

e ex

emp

lary

. eplan download, configurator www.igus.eu/en/CF11D Pre-harnessed igus® energy supply systems for machine tool manufacture. e-chain®: System E4/4

Halogen-free Following EN 50267-2-1.

CE Following 2006/95/EG

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/55/EU (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1

Typical application area

� for maximum load requirements� almost unlimited resistance to oil, also with bio-oils� indoor and outdoor applications without direct sun radiation� especially for freely suspended and gliding travel distances up to 400 m� Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,

semiconductor insertion, indoor cranes, low-temperature applications

181

CF11.DTPE

10 x d

CF11.DTPE

10 x d

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 180

Page 12: igus Measuring cables

CF11.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5 72 168

CF11.002.D (3x(2x0,14)C+2x(0,5)C)C 10,5 74 180

CF11.003.D (3x(2x0,14)+2x1,0)C 8,5 55 118

CF11.004.D (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 11,5 82 188

CF11.005.D (4x(2x0,14)+4x0,5)C 9,5 61 137

CF11.006.D(4) (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,0 84 193

CF11.007.D(2) (2x2x0,34)C 6,0 29 62CF11.008.D (3x(2x0,25))C 7,5 33 77CF11.009.D (4x(2x0,25)+2x0,5)C 9,5 60 131

CF11.010.D (4x(2x0,25)+2x1,0)C 9,5 72 153

CF11.011.D (4x(2x0,34)+4x0,5)C 10,5 87 192

CF11.012.D (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 11,5 90 213

CF11.013.D (3x(2x0,14)C+2x0,5)C 9,5 63 145

CF11.014.D(1) (4x(2x0,25)C+2x0,5)C 11,5 86 203

CF11.015.D (4x(2x0,14)+4x0,5)C 9,5 61 133

(1) Delivery time upon inquiry.(4) manufactured without inner jacketNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Delivery programPart No.

Number of cores andconductor nominal crosssection [mm2]

External diameterapprox. [mm]

Copperindex[kg/km]

Weight[kg/km]

Image exemplary.

Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)TPE Measuring system cable CF11.D

182

CF11.001.D 3x(2x0,14)C green/yellow, black/brown, red/orange(4x0,14) gray, blue, white-yellow, white-black(2x0,5) brown-red, brown-blue

CF11.002.D 3x(2x0,14)C green/yellow, black/brown, red/orange2x(0,5)C black, red

CF11.003.D 3x(2x0,14) white/brown, green/yellow, gray/pink2x1,0 blue, red

CF11.004.D 2x(2x2x0,14) brown/green, violet/yellow, gray/pink, red/black(4x0,14)C yellow-black, red-black, green-black, blue-black

4x0,5 brown-green, white-green, blue, whiteCF11.005.D 4x(2x0,14) white/brown, green/yellow, gray/pink, blue/red

4x0,5 black, violet, gray-pink, red-blueCF11.006.D(4) 3x(2x0,14)C green/yellow, brown/black, red/orange

(4x0,14) blue, gray, white-black, white-yellow(4x0,23) brown-yellow, brown-gray, green-black, green-red(2x0,5) brown-red, brown-blue

CF11.007.D 4x0,34 white, green, brown, yellow (star-quad stranding)CF11.008.D 3x(2x0,25) white/brown, green/yellow, gray/pinkCF11.009.D 4x(2x0,25) brown/green, blue/violet, gray/pink, red/black

2x0,5 white, brownCF11.010.D 4x(2x0,25) brown/green, blue/violet, gray/pink, red/black

2x1,0 white, brownCF11.011.D 4x(2x0,34) black/brown, red/orange, yellow/green, blue/violet

4x0,5 blue-white, black-white, red-white, yellow-whiteCF11.012.D 3x(2x0,14)C green/yellow, white/gray, blue/red

(3x0,14)C red, green, brown6x0,14 blue, gray, gray, yellow, pink, violet2x0,5 brown-red, brown-blue

CF11.013.D 3x(2x0,14)C white/brown, green/yellow, gray/pink2x0,5 red, blue

CF11.014.D(1) 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red2x0,5 black (numeral printing 1-2)

CF11.015.D 4x(2x0,14) brown/green, violet/yellow, gray/pink, red/black4x0,5 blue, white, brown-green, white-green

Delivery programPart No.

Core group Colour code

Other types Page 186

183

CF11.DTPE

10 x d

CF11.DTPE

10 x d

eplan download, configurator www.igus.eu/en/CF11D

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 182

Page 13: igus Measuring cables

CF11.016.D(1) (3x(2x0,25)C)C 9,5 59 138CF11.017.D(4) (4x(2x0,14)+(4x0,14)C+4x1,0)C 11,5 105 234

CF11.018.D(4) (2x(2x0,25)+2x0,5)C 7,0 36 72

CF11.019.D(4) (3x(2x0,25)C+(3x0,25)+2x1,0)C 11,5 96 218

CF11.021.D (3x(2x0,5+2x0,25)+(4x0,25))C 11,0 92 203

CF11.022.D (5x0,5+(2x0,25))C 8,5 50 115

CF11.025.D (3x(2x0,14)C+(2x0,5)C)C 10,5 73 174

CF11.027.D (5x(2x0,14)+2x0,5)C 9,0 52 115

CF11.032.D(1)/(15) 3x(2x0,14)C+(3x0,14)C 8,0 61 144

CF11.033.D(15) 4x(2x0,14)C+2x(1,0)C 10,0 97 230

CF11.034.D(15) 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 11,5 105 177

CF11.038.D (3x2x0,14+1x2x0,34)C 7,5 36 67

(1) Delivery time upon inquiry.(4) manufactured without inner jacket(15) manufactured without overall shieldNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core* New in this catalogue.

Delivery programPart No.

Number of cores andconductor nominal crosssection [mm2]

External diameterapprox. [mm]

Copperindex[kg/km]

Weight[kg/km]

Image exemplary.

Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)TPE Measuring system cable CF11.D

184

CF11.016.D(1) 3x(2x0,25)C white/brown, green/yellow, gray/pinkCF11.017.D(4) 4x(2x0,14) red/black, green/brown, yellow/violet, pink/gray

(4x0,14)C blue-black, red-black, yellow-black, green-black4x1,0 white-green, brown-green, blue, white

CF11.018.D(4) 2x(2x0,25) red/black, gray/pink2x0,5 white, brown

CF11.019.D(4) 3x(2x0,25)C brown/green, gray/pink, red/black(3x0,25) blue, yellow, violet

2x1,0 white, brownCF11.021.D 3x(2x0,25) white/yellow, white/gray, black/orange

3x(2x0,5) black (numeral printing 1-6)(4x0,25) white, gray, brown, black

CF11.022.D 5x0,5 blue, green, yellow, gray, pink(2x0,25) white, brown

CF11.025.D 3x(2x0,14) green/yellow, blue/red, gray/pink(2x0,5) white, brown

CF11.027.D 5x(2x0,14) green/brown, gray/yellow, white/violet, black/red, blue/pink2x0,5 white-green, white-red

CF11.032.D(1)/(15) 3x(2x0,14)C yellow/black, red/black, green/black(3x0,14)C black, gray, pink

CF11.033.D(15) 4x(2x0,14)C yellow/black, red/black, green/black, blue/black2x(1,0)C white, brown

CF11.034.D(15) 3x(2x0,14)C green/black, violet/black, blue/black(4x0,14)C yellow, red-black, yellow-black, red

2x(2x0,5)C black/brown, black/whiteCF11.038.D 3x2x0,14 white/brown, green/yellow, gray/pink

1x2x0,34 blue/red

Delivery programPart No.

Core group Colour code

Order example: CF11.021.D – in your desired length (0,5 m steps)CF11.D chainflex® series .021 Code Measuring system

Please use www.chainflex.eu/en/CF11D for your online order.

Delivery time 24h or today.Delivery time means time until shipping of goods.

New*

185

CF11.DTPE

10 x d

CF11.DTPE

10 x d

Other types Page 184

eplan download, configurator www.igus.eu/en/CF11D

... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu

950 types from stock no cutting costs ...(for up to 10 cuts of the same type)

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:58 Seite 184