IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

21
IFE TARGET CHAMBER IFE TARGET CHAMBER VACUUM PUMPING SYSTEM VACUUM PUMPING SYSTEM 11m Radius Case 11m Radius Case 1 C. Gentile, 1 C. Priniski, 2 J. Sethian, 1 R. Parsells, 1 S. Langish, 1 L. Ciebiera, 1 W. Blanchard, 1 R. Yager, 1 C. Jun 1 Princeton Plasma Physics Laboratory 2 Naval Research Laboratory 12th HAPL Meeting, Lawrence Livermore National Laboratory June 20-21, 2005

description

IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case. 1 C. Gentile, 1 C. Priniski, 2 J. Sethian, 1 R. Parsells, 1 S. Langish, 1 L. Ciebiera, 1 W. Blanchard, 1 R. Yager, 1 C. Jun 1 Princeton Plasma Physics Laboratory 2 Naval Research Laboratory - PowerPoint PPT Presentation

Transcript of IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

Page 1: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

IFE TARGET CHAMBER IFE TARGET CHAMBER VACUUM PUMPING SYSTEMVACUUM PUMPING SYSTEM

11m Radius Case11m Radius Case1C. Gentile, 1C. Priniski, 2J. Sethian, 1R. Parsells, 1S. Langish,

1L. Ciebiera, 1W. Blanchard, 1R. Yager, 1C. Jun1 Princeton Plasma Physics Laboratory

2 Naval Research Laboratory

12th HAPL Meeting, Lawrence Livermore National Laboratory

June 20-21, 2005

Page 2: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

Requirements:Requirements:Requirement Action

• Design vacuum pum pingsystem to m eet requireme ntsof IFE target chamb er (11m r)in accordance with systemspecifications

• Proposed conceptualdesign em ployingconventional com pone ntsindicates that systemrequirements can beachieved

• Provide a cost-effective/econom ical system to me etrequirements

• Emp loy pum ps form ultiple purposes (i.e.,Kinney pum ps alsoconfigured to rough downtarget cham ber throughbeam ports)

• Emp loy comm ercial off-the -shelf comp onen tswith good operationalhistory

• Provide a system for“eventual” D-T operations

• Proposed systemconfigured to transition toD-T operations

Email correspondence .: J. Sethian “11 meter radius IFE Target Chamber”, May 12th, 2005.

Page 3: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

Design Parameters:Design Parameters: Employ commercial off-the-shelf (COTS) components to minimize costs.

Employ high efficiency turbo molecular pumps backed by roughing pumps.

Employ components which have good operational history in similar environments.

Develop an accurate cost estimate from vendors; detailed quotes.

Design system to transition to D-T operations with minimal modifications.

Design system to meet base pressure and operation pressure in accordance with 5 Hz operation.

Page 4: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

System Specifications:System Specifications:

Target Chamber Size• Inner radius = 11 m• Target chamber volume 5,575,279 liters• Total laser duct volume 150,796 liters• Total volume (with 60 beam ports) 5,726,085

liters Target Chamber Pressures

• Operational base pressure = 0.5 mtorr• Gas load = 141 torr-liters/sec• Total system in-leakage = 1x10-5 torr-liters/sec

Page 5: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

Target ChamberTarget Chamber

Page 6: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

Vacuum Pumping System:Vacuum Pumping System: Target Chamber Pumping

• TMP pumping through (laser port) beam ducts = 60• TMP’s (Varian-V 6000) = 2 TMP’s /duct• TMPS’s total =120• TMP backing pumps (Kinney KMBD-2000) = 1/6 TMP’s• Backing pumps total = 20

Outboard Beam Duct Pumping• TMP’s (Varian-V 2000 HT) = 1/beam port• TMPS’s total =60

TMP Heat Loading• Gas Load T=1000K–4000K, no operational effect

System Pumpdown• From 760 torr to 0.5 mtorr (initial conditions) 18 hrs

Page 7: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 8: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 9: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 10: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

Laser Duct Pumping Continued

B

GIMM

BeamTube

"Vacuum"Window

Turbo-V 2000 HT E

HeliflexGasketsK

10” VAT Valve

Page 11: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 12: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 13: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 14: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 15: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 16: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 17: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 18: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 19: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 20: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case
Page 21: IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case

Vacuum System CostsVacuum System CostsKey Equipment Name Unit Cost Qty Total Qty

Discount Discount Total Total

A Varian Turbo-V 6000 (on beam ducts) 70,000.00$ 120 8,400,000.00$ 20% 1,680,000.00$ 6,720,000.00$

B Varian Turbo-V 2000 HT (on outboard beam tube)

25,000.00$ 60 1,500,000.00$ 20% 300,000.00$ 1,200,000.00$

C Kinney KMBD -2000 Backing Pumps 41,000.00$ 20 820,000.00$ 20% 164,000.00$ 656,000.00$

D TMP/Inboard beam duct isolation valve (VAT valves, 20" throughput)

20,000.00$ 120 2,400,000.00$ 20% 480,000.00$ 1,920,000.00$

E Outboard beam duct (TMP) Isolation Valves (VAT valves, 10" throughput)

12,000.00$ 60 720,000.00$ 20% 144,000.00$ 576,000.00$

F Roughing Valves (between TMP exhaust/Kinney Inlet)

8,000.00$ 20 160,000.00$ 20% 32,000.00$ 128,000.00$

G Gate Valves (after Kinney discharge) 8,000.00$ 20 160,000.00$ 20% 32,000.00$ 128,000.00$

H Dycor RGA (0-200 AMU w/ pumping system) 23,000.00$ 4 92,000.00$ 5% 4,600.00$ 87,400.00$

I Instrumentation and Control 250,000.00$ 250,000.00$ 0% -$ 250,000.00$

JTarget Chamber Isolation Valves (for roughing pump interface-VAT valves, 8" throughput)

8,000.00$ 10 80,000.00$ 10% 8,000.00$ 72,000.00$

K Heli-Flex Seals 500.00$ 380 190,000.00$ 5% 9,500.00$ 190,000.00$

J Gas Holding Tanks (10 m 3) 150,000.00$ 4 600,000.00$ 0% -$ 600,000.00$

M Interfacing Piping 350,000.00$ 350,000.00$ 0% -$ 350,000.00$

N High Vacuum Ion Gage 5,000.00$ 6 30,000.00$ 0% -$ 5,000.00$

Totals 15,752,000.00$ 2,854,100.00$ 12,882,400.00$

Vacuum System for a Laser IFE Chamber Component Cost Estimate