IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This...
Transcript of IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This...
STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.
(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,
approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.
IES LM-79-08 MEASUREMENT AND TEST REPORT
For
Shenzhen XinShengYang Opto-electronics Technology
Co.,Ltd D Building, 1st Ind.Park, Fenghuang 3rd Ind. Zone, Fuyong, Bao’an District, Shenzhen, China
Test Model: XSY-FLHP50W
Report Type: Electrical and Photometric tests including: Luminous Flux,
Color, Luminous Intensity Distribution
Test Engineer: Daniel Duan
Report Number: RSZ160118505-10
Test Date: 2016-01-22 to 2016-01-23
Report Date: 2016-01-26
Reviewed By: Jeanne Han/Safety Manager
Prepared By:
Bay Area Compliance Laboratories Corp. (Shenzhen)
6/F, the 3rd Phase of WanLi Industrial Building,
ShiHua Road, FuTian Free Trade Zone
Shenzhen, Guangdong, China
Tel: +86-755-33320018
Fax: +86-755-33320008
Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial
Area, Tangxia Town, Dongguan, Guangdong, P.R.China.
Accreditation: The NVLAP Lab Code is 200707-0.
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 2 of 12 The NVLAP Lab Code is 200707-0.
1. Product Description
General Information:
One sample was received on 2016-01-18 and used for testing.
Model Tested: XSY-FLHP50W
Manufacturer: Shenzhen XinShengYang Opto-electronics Technology Co.,Ltd
Brand Name: XSY
Product Designation: LED flood light
Burning Time Before Test: 0hour(For New Products)
Rated Values:
Rated Voltage/Frequency: 100-240VAC 50/60Hz
Rated Power: 50 W
Nominal CCT: 5000K
Nominal Lumen Output: 5500Im
2. Standards Used
IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products
ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting
3. Description of Test Equipment
Device Manufacture Model No Serial No Test Range Calibration
date
Calibration
due date
Integrating Sphere SENSING SPR-600 S09008 25~50℃ 2015-03-25 2016-03-24
Spectral
photometer SENSING SPR3000 90902027 350nm~800nm 2015-03-25 2016-03-24
Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2015-03-05 2016-03-04
AC Power Supply ALL Power APW-
105N 970663 220V±10% 50HZ 2015-03-05 2016-03-04
Standard Light
Source EVERFINE D204 01331191 24V/100W 2015-08-27 2016-08-26
Thermal Meter SENSING N/A N/A 25、50℃ 2015-03-05 2016-03-04
DC Power Supply ITECH IT6154 0061 0417 6471 0010
19 0~32V 2015-03-05 2016-03-04
AC Power Supply EVERFINE VPS1030
PWM 1012017 0-150V, 0-300V 2015-03-05 2016-03-04
DC Power Supply EVERFINE WY12010 1009009 30V/5A 2015-03-05 2016-03-04
Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2015-03-05 2016-03-04
Goniophotometer EVERFINE GO-
R5000 YG108492N10120001 1600mm,3000W/10A 2015-03-20 2016-03-19
Wireless Remote
Sensor N/A 433MHz N/A 0℃~50℃;-20℃~60℃ 2015-03-24 2016-03-23
Standard Light
Source EVERFINE D908 1012003 N/A 2015-09-08 2016-09-07
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 3 of 12 The NVLAP Lab Code is 200707-0.
Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).
4. Test Method
Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.
Integrating Sphere System
The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement.
4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.
The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2) , at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.
Goniophotometer System
The goniophotometer system is calibrated by standard light source before measurement.
Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial
uniformity. The product was operated in its intended orientation in application and was recorded in this report.
The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 4 of 12 The NVLAP Lab Code is 200707-0.
5. Test Result
[Integrating Sphere System]
Total operating time for integrating sphere test: 1.0 hour
Test orientation: Downward
Electrical Measurement
Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor
240.04 50 0.2239 51.15 0.952
Photometric Measurement
Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv
5927.498 17.840 115.885 4912 0.0006
Chromaticity Coordinate
x y u v u' v'
0.3478 0.3550 0.2119 0.3245 0.2119 0.4867
Color Rendering Index
Ra
74.8
R1 R2 R3 R4
73 80 84 75
R5 R6 R7 R8
72 71 84 60
R9 R10 R11 R12
-17 51 71 42
R13 R14 R15
75 90 68
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 5 of 12 The NVLAP Lab Code is 200707-0.
Relative Spectral Power Distribution
nm mW nm mW nm mW nm mW nm mW
380 2.532E-03 465 2.604E-01 550 4.110E-01 635 2.386E-01 720 2.555E-02
385 9.222E-04 470 1.842E-01 555 4.122E-01 640 2.154E-01 725 2.234E-02
390 6.438E-04 475 1.241E-01 560 4.239E-01 645 1.919E-01 730 1.939E-02
395 1.144E-03 480 9.289E-02 565 4.287E-01 650 1.737E-01 735 1.648E-02
400 1.291E-03 485 8.568E-02 570 4.276E-01 655 1.527E-01 740 1.498E-02
405 2.508E-03 490 9.256E-02 575 4.317E-01 660 1.334E-01 745 1.254E-02
410 6.650E-03 495 1.134E-01 580 4.333E-01 665 1.189E-01 750 1.075E-02
415 1.667E-02 500 1.505E-01 585 4.248E-01 670 1.048E-01 755 9.654E-03
420 3.713E-02 505 1.956E-01 590 4.194E-01 675 9.043E-02 760 8.377E-03
425 7.511E-02 510 2.410E-01 595 4.085E-01 680 7.981E-02 765 7.133E-03
430 1.415E-01 515 2.870E-01 600 3.934E-01 685 6.938E-02 770 6.247E-03
435 2.393E-01 520 3.226E-01 605 3.757E-01 690 5.963E-02 775 5.565E-03
440 3.702E-01 525 3.446E-01 610 3.593E-01 695 5.233E-02 780 4.742E-03
445 5.463E-01 530 3.644E-01 615 3.324E-01 700 4.492E-02
450 6.617E-01 535 3.795E-01 620 3.121E-01 705 3.904E-02
455 5.784E-01 540 3.886E-01 625 2.870E-01 710 3.458E-02
460 3.909E-01 545 4.010E-01 630 2.600E-01 715 2.958E-02
0.0
0.2
0.4
0.6
0.8
1.0
1.2
380 440 500 560 620 680 740 800
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 6 of 12 The NVLAP Lab Code is 200707-0.
CIE 1931 x y Chromaticity Diagram
7-Step Chromaticity Quadrangles
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0.30
0.35
0.40
0.45
0.30 0.35 0.40 0.45 0.50 0.55
sample
7-STEP 2200K
7-STEP 2500K
7-STEP 2700K
7-STEP 3000K
7-STEP 3500K
7-STEP 4000K
7-STEP 4500K
7-STEP 5000K
7-STEP 5700K
7-STEP 6500K
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 7 of 12 The NVLAP Lab Code is 200707-0.
[Goniophotometer System]
Total operating time for luminous intensity distribution: 1.0 hours
Test orientation: Downward
Electrical Measurement
Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor
240.08 50 0.2233 50.96 0.9506
Photometric Measurement
Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)
5942.66 116.61 2212 1.29 1.35
Luminous Intensity Distribution
C0/180 C45/225 C90/270 C135/315 AVG.
Beam Angle (50% Imax): 106.7 114.2 112.5 114.7 112.0
Field Angle (10% Imax): 143.4 145.5 146.2 146.0 145.3
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 8 of 12 The NVLAP Lab Code is 200707-0.
Luminous Intensity (cd) Distribution Data
C
0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ
0.0° 2201 2201 2201 2201 2201 2201 2201 2201
5.0° 2207 2203 2201 2200 2201 2201 2195 2192
10.0° 2181 2174 2176 2192 2199 2193 2184 2178
15.0° 2135 2137 2161 2178 2178 2177 2158 2141
20.0° 2073 2093 2128 2143 2157 2147 2126 2092
25.0° 2004 2029 2075 2115 2120 2105 2069 2037
30.0° 1910 1942 2004 2036 2043 2043 2006 1946
35.0° 1801 1843 1899 1923 1909 1938 1919 1849
40.0° 1661 1710 1770 1766 1750 1779 1786 1727
45.0° 1505 1561 1612 1596 1577 1602 1630 1577
50.0° 1217 1341 1418 1377 1359 1389 1420 1417
55.0° 1018 1080 1202 1172 1162 1180 1229 1123
60.0° 753 789 864 930 802 940 966 897
65.0° 478 524 583 585 582 610 692 610
70.0° 254 286 288 320 314 363 351 351
75.0° 100 109 99 120 127 130 140 152
80.0° 18 16 18 13 12 15 33 30
85.0° 11 9 7 5 5 6 8 11
90.0° 0 0 0 0 0 0 0 3
95.0° 0 0 0 0 0 0 0 0
100.0° 0 0 1 0 0 0 0 0
105.0° 1 1 1 1 1 1 1 1
110.0° 1 1 1 1 1 1 1 1
115.0° 1 1 1 1 1 1 1 1
120.0° 1 1 1 1 1 1 1 1
125.0° 1 1 1 1 1 1 1 1
130.0° 1 1 1 1 1 1 1 1
135.0° 1 1 1 1 1 1 1 1
140.0° 1 1 1 1 1 1 1 1
145.0° 2 2 2 2 2 2 2 2
150.0° 2 2 2 2 2 2 2 2
155.0° 2 2 2 2 2 2 2 2
160.0° 3 3 3 3 3 3 3 3
165.0° 2 2 2 2 2 3 3 3
170.0° 2 2 2 2 2 2 2 2
175.0° 2 2 2 2 2 2 2 2
180.0° 2 2 2 2 2 2 2 2
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 9 of 12 The NVLAP Lab Code is 200707-0.
Luminous Intensity (cd) Distribution Data (cont.)
C
180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ
0.0° 2201 2201 2201 2201 2201 2201 2201 2201
5.0° 2198 2200 2202 2208 2210 2209 2208 2206
10.0° 2181 2186 2192 2201 2205 2195 2192 2184
15.0° 2148 2160 2169 2180 2180 2172 2156 2146
20.0° 2086 2102 2126 2149 2157 2144 2118 2089
25.0° 1998 2042 2077 2117 2127 2107 2055 2022
30.0° 1915 1951 2015 2049 2039 2041 1989 1925
35.0° 1803 1840 1926 1923 1902 1923 1909 1819
40.0° 1672 1723 1793 1781 1765 1774 1760 1689
45.0° 1521 1584 1620 1608 1555 1596 1612 1542
50.0° 1343 1418 1445 1373 1353 1375 1420 1342
55.0° 1051 1149 1227 1183 1167 1179 1205 1090
60.0° 785 894 990 968 801 959 899 797
65.0° 543 624 684 611 599 593 655 531
70.0° 309 354 360 370 309 325 324 300
75.0° 126 157 176 179 151 145 131 124
80.0° 21 21 37 19 15 17 28 19
85.0° 13 13 10 8 6 8 10 11
90.0° 0 0 0 0 0 0 0 0
95.0° 0 0 0 0 0 0 0 0
100.0° 0 0 0 0 0 0 0 0
105.0° 0 0 0 0 0 0 0 0
110.0° 0 0 0 0 0 0 0 0
115.0° 0 0 0 1 1 1 0 0
120.0° 1 1 1 1 1 1 1 1
125.0° 1 1 1 1 1 1 1 1
130.0° 1 1 1 1 1 1 1 1
135.0° 1 1 1 1 1 1 1 1
140.0° 1 1 1 1 1 1 1 1
145.0° 1 1 1 1 1 1 1 1
150.0° 1 1 1 1 1 1 1 1
155.0° 1 1 2 2 2 2 2 2
160.0° 2 2 2 2 2 2 2 2
165.0° 2 2 2 2 2 2 2 2
170.0° 2 2 2 2 2 2 2 2
175.0° 2 2 2 2 2 2 2 2
180.0° 2 2 2 2 2 2 2 2
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 10 of 12 The NVLAP Lab Code is 200707-0.
Average Area Illumination Figure
Height (m) Diameter
(cm) Eavg(lx) Emax(lx)
0.5 148.26 2790.0 8845.0
1.0 296.51 697.6 2211.0
1.5 444.77 310.0 982.8
2.0 593.02 174.4 552.8
2.5 741.28 111.6 353.8
3.0 889.54 77.5 245.7
3.5 1037.79 56.9 180.5
4.0 1186.05 43.6 138.2
4.5 1334.30 34.5 109.2
5.0 1482.56 27.9 88.5
Angle: 112.0 °. Flux out: 4817.0 lm
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 11 of 12 The NVLAP Lab Code is 200707-0.
Zonal Lumen Density Measurement
Deg Flux (lm) %
Deg Flux (lm) %
0-5 52.7 0.89 0-5 52.7 0.89
5-10 157.1 2.64 0-10 209.8 3.53
10-15 258.0 4.34 0-15 467.8 7.87
15-20 352.9 5.94 0-20 820.6 13.81
20-25 439.4 7.39 0-25 1260.1 21.20
25-30 514.3 8.66 0-30 1774.4 29.86
30-35 570.6 9.60 0-35 2345.0 39.46
35-40 605.4 10.19 0-40 2950.4 49.65
40-45 616.4 10.37 0-45 3566.8 60.02
45-50 597.8 10.06 0-50 4164.6 70.08
50-55 550.3 9.26 0-55 4714.9 79.34
55-60 472.1 7.94 0-60 5187.0 87.28
60-65 351.8 5.92 0-65 5538.8 93.20
65-70 234.1 3.94 0-70 5772.9 97.14
70-75 118.3 1.99 0-75 5891.2 99.13
75-80 36.2 0.61 0-80 5927.4 99.74
80-85 7.0 0.12 0-85 5934.5 99.86
85-90 2.7 0.05 0-90 5937.2 99.91
90-95 0.1 0.00 0-95 5937.3 99.91
95-100 0.2 0.00 0-100 5937.5 99.91
100-105 0.2 0.01 0-105 5937.7 99.92
105-110 0.3 0.00 0-110 5937.9 99.92
110-115 0.3 0.01 0-115 5938.2 99.93
115-120 0.3 0.00 0-120 5938.5 99.93
120-125 0.3 0.01 0-125 5938.8 99.94
125-130 0.4 0.00 0-130 5939.2 99.94
130-135 0.4 0.01 0-135 5939.6 99.95
135-140 0.4 0.01 0-140 5940.0 99.96
140-145 0.5 0.00 0-145 5940.5 99.96
145-150 0.5 0.01 0-150 5941.0 99.97
150-155 0.5 0.01 0-155 5941.5 99.98
155-160 0.4 0.01 0-160 5941.9 99.99
160-165 0.3 0.00 0-165 5942.2 99.99
165-170 0.2 0.01 0-170 5942.5 100.00
170-175 0.1 0.00 0-175 5942.6 100.00
175-180 0.1 0.00 0-180 5942.7 100.00
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ160118505-10 Page 12 of 12 The NVLAP Lab Code is 200707-0.
6. Product Photo
***********END OF REPORT***********