IEC 61850 enabled UniGear
description
Transcript of IEC 61850 enabled UniGear
IEC 61850 enabled UniGearMay 2013
Tenders
0 1 0 0 1 1 0 0 1 0 0 1 1 0 1 0 1 0 1 0 0 1 0 1 0 1 1 1 1 0 0 0 1 0 1 0 1 0 1 00 1 1 0 0 0 1 1 1 0 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 1 1 1 0 0 0 1 1 0 1 0 1 00 1 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 0 1 0 1 0 1 0
© ABB GroupApril 22, 2023 | Slide 2
IEC 61850 enabled MV Primary switchgearMain Accessories
ABB’s Relion® IEDs with IEC 61850 native support Managed Ethernet Switch/esCommunication Links
H01 H02 H03 H04 H05
© ABB GroupApril 22, 2023 | Slide 3
IEC 61850 enabled MV Primary switchgearMain Accessories / IED with IEC 61850-8-1 interface
Converter is needed (communication gateway, card …) Supported communication
Vertical
© ABB GroupApril 22, 2023 | Slide 4
IEC 61850 enabled MV Primary switchgearMain Accessories / IED with IEC 61850-8-1 interface
Relion® protection and control True, native support for IEC 61850 Supported communications
Vertical Horizontal GOOSE
Dedicated web page www.abb.com/relion
© ABB GroupApril 22, 2023 | Slide 5
IEC 61850 enabled MV Primary switchgearMain Accessories / Ethernet Switch
Managed Ethernet Switch “Substation hardened” to the same level as IEDs Recommended to use all switches from the same vendor,
especially when building ring architecture
ABB AFS family
© ABB GroupApril 22, 2023 | Slide 6
IEC 61850 enabled MV Primary switchgearMain Accessories / Ethernet Switch
Managed Ethernet Switch Type of switch
Compact – Fixed number of ports (connections) Modular – Variable number of ports and their types
Type of Port Copper / Fiber
© ABB GroupApril 22, 2023 | Slide 7
IEC 61850 enabled MV Primary switchgearMain Accessories / Communication Links
Optical: Duplex Patch cord with LC-LC connectors
Patch cord (cable) Electrical or optical cable
used to connect one device to another for data routing
It is terminated by connectors on both ends
Electrical cable is susceptible to EMI, therefore should be only used inside cabinets
Electrical : STP cable Cat.6 or better with RJ45-RJ45 connectors
LC
RJ45
© ABB GroupApril 22, 2023 | Slide 8
IEC 61850 enabled MV Primary switchgearSingle Network Architecture
Typical architecture IEDs are connected directly to Managed Ethernet switch
Supported by all IEDs
Backbone Ring network
… …
© ABB GroupApril 22, 2023 | Slide 9
IEC 61850 enabled MV Primary switchgearRing (Self-healing)
Data is sent into both directions on the ring Essential part is Managed Ethernet switch Supported by 611, 615 (except RED), 620 Series IEDs
max. 30 IEDs
© ABB GroupApril 22, 2023 | Slide 10
IEC 61850 enabled MV Primary switchgearRing (HSR) - Redundant Network Architecture
High-availability Seamless Redundancy (HSR) Same data is sent into both directions on the ring Eliminating communication downtime Supported by 615 Series IEC (except RED) and 620 Series IEC
max. 30 IEDs
© ABB GroupApril 22, 2023 | Slide 11
IEC 61850 enabled MV Primary switchgearDouble (PRP) - Redundant Network Architecture
Parallel Redundancy Protocol (PRP) Same data is sent to both networks with identical topology Eliminating communication downtime Supported by 615 Series IEC (except RED) and 620 Series IEC
LAN BLA
N A
© ABB GroupApril 22, 2023 | Slide 12
IEC 61850 enabled MV Primary switchgearEthernet Network Topology
Ring Built-in redundancy Centralized /Decentralized
Interconnection Fiber optic
Ring Network Topology
Decentralized ring Architecture
© ABB GroupApril 22, 2023 | Slide 13
IEC 61850 enabled MV Primary switchgearAccessories Layout
Ethernet switch RSG2100 assembled in LVC of UniGear
Location Inside Low Voltage
Compartment of the switchgear panels
Typically in Bus riser, Metering panel
Main benefits Cubicles are ready for
connection Saving space in
substation building Shorter communication
links Cheaper solution
© ABB GroupApril 22, 2023 | Slide 14
IEC 61850 enabled MV Primary switchgearUniGear Pro
Global Tendering Tool for Air-insulated UniGear panels
© ABB GroupApril 22, 2023 | Slide 15
IEC 61850 enabled MV Primary switchgearIED Communication Protocol and Media
3. Select IED Communication protocol• IEC61850 Single + GOOSE• IEC61850 Ring (Self-healing) + GOOSE• IEC61850 Ring (HSR) + GOOSE• IEC61850 Double (PRP) + GOOSE• IEC61850 Single• IEC61850 Ring (Self-healing)• IEC61850 Ring (HSR)• IEC61850 Double (PRP)
4. Select Communication media• Galvanic (RJ45)• Optic Glass Fiber
1. Open Switchgeardata window
2. Select tab Control
© ABB GroupApril 22, 2023 | Slide 16
3. Select sub-tabRelays
2. Select tabFunctional unit
1. Open Paneldata window
4. Press Add button
IEC 61850 enabled MV Primary switchgearIntelligent Electronic Device (Relay)
5. Select Relay Applied filters• Communication protocol• Communication medium
6. Press OK button
© ABB GroupApril 22, 2023 | Slide 17
IEC 61850 enabled MV Primary switchgearEthernet Switches
1. Open Switchgear data or Panel data window
2. Select tab Additional articles
3. Select TypeCommunications
4. Select MakeABB …
5. Select VariantEthernet Switches
6. Select Type of Ethernet Switch
7. Press Add button
© ABB GroupApril 22, 2023 | Slide 18
IEC 61850 enabled MV Primary switchgearCommunication cables (Patchcords)
1. Open Switchgear data or Panel data window
3. Select sub-tab Additional articles
4. Select TypeCommunications
5. Select MakeMiscellaneous
6. Select VariantPatchcords
7. Select Type of Patchcord
8. Press Add button
2. Select tab Functional unit