IEC 61850 enabled UniGear

19
IEC 61850 enabled UniGear May 2013 Tenders 1 1 0 0 1 0 0 1 1 0 1 0 1 0 1 0 0 1 0 1 0 1 1 1 1 0 0 0 1 0 1 0 1 0 0 1 1 1 0 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 1 1 1 0 0 0 1 1 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 0 1 0 1 0

description

0 1 0 0 1 1 0 0 1 0 0 1 1 0 1 0 1 0 1 0 0 1 0 1 0 1 1 1 1 0 0 0 1 0 1 0 1 0 1 0 0 1 1 0 0 0 1 1 1 0 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 1 1 1 0 0 0 1 1 0 1 0 1 0 0 1 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 0 1 0 1 0 1 0 . May 2013. IEC 61850 enabled UniGear. Tenders. - PowerPoint PPT Presentation

Transcript of IEC 61850 enabled UniGear

Page 1: IEC 61850 enabled  UniGear

IEC 61850 enabled UniGearMay 2013

Tenders

0 1 0 0 1 1 0 0 1 0 0 1 1 0 1 0 1 0 1 0 0 1 0 1 0 1 1 1 1 0 0 0 1 0 1 0 1 0 1 00 1 1 0 0 0 1 1 1 0 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 1 1 1 0 0 0 1 1 0 1 0 1 00 1 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 0 1 0 1 0 1 0

Page 2: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 2

IEC 61850 enabled MV Primary switchgearMain Accessories

ABB’s Relion® IEDs with IEC 61850 native support Managed Ethernet Switch/esCommunication Links

H01 H02 H03 H04 H05

Page 3: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 3

IEC 61850 enabled MV Primary switchgearMain Accessories / IED with IEC 61850-8-1 interface

Converter is needed (communication gateway, card …) Supported communication

Vertical

Page 4: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 4

IEC 61850 enabled MV Primary switchgearMain Accessories / IED with IEC 61850-8-1 interface

Relion® protection and control True, native support for IEC 61850 Supported communications

Vertical Horizontal GOOSE

Dedicated web page www.abb.com/relion

Page 5: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 5

IEC 61850 enabled MV Primary switchgearMain Accessories / Ethernet Switch

Managed Ethernet Switch “Substation hardened” to the same level as IEDs Recommended to use all switches from the same vendor,

especially when building ring architecture

ABB AFS family

Page 6: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 6

IEC 61850 enabled MV Primary switchgearMain Accessories / Ethernet Switch

Managed Ethernet Switch Type of switch

Compact – Fixed number of ports (connections) Modular – Variable number of ports and their types

Type of Port Copper / Fiber

Page 7: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 7

IEC 61850 enabled MV Primary switchgearMain Accessories / Communication Links

Optical: Duplex Patch cord with LC-LC connectors

Patch cord (cable) Electrical or optical cable

used to connect one device to another for data routing

It is terminated by connectors on both ends

Electrical cable is susceptible to EMI, therefore should be only used inside cabinets

Electrical : STP cable Cat.6 or better with RJ45-RJ45 connectors

LC

RJ45

Page 8: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 8

IEC 61850 enabled MV Primary switchgearSingle Network Architecture

Typical architecture IEDs are connected directly to Managed Ethernet switch

Supported by all IEDs

Backbone Ring network

… …

Page 9: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 9

IEC 61850 enabled MV Primary switchgearRing (Self-healing)

Data is sent into both directions on the ring Essential part is Managed Ethernet switch Supported by 611, 615 (except RED), 620 Series IEDs

max. 30 IEDs

Page 10: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 10

IEC 61850 enabled MV Primary switchgearRing (HSR) - Redundant Network Architecture

High-availability Seamless Redundancy (HSR) Same data is sent into both directions on the ring Eliminating communication downtime Supported by 615 Series IEC (except RED) and 620 Series IEC

max. 30 IEDs

Page 11: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 11

IEC 61850 enabled MV Primary switchgearDouble (PRP) - Redundant Network Architecture

Parallel Redundancy Protocol (PRP) Same data is sent to both networks with identical topology Eliminating communication downtime Supported by 615 Series IEC (except RED) and 620 Series IEC

LAN BLA

N A

Page 12: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 12

IEC 61850 enabled MV Primary switchgearEthernet Network Topology

Ring Built-in redundancy Centralized /Decentralized

Interconnection Fiber optic

Ring Network Topology

Decentralized ring Architecture

Page 13: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 13

IEC 61850 enabled MV Primary switchgearAccessories Layout

Ethernet switch RSG2100 assembled in LVC of UniGear

Location Inside Low Voltage

Compartment of the switchgear panels

Typically in Bus riser, Metering panel

Main benefits Cubicles are ready for

connection Saving space in

substation building Shorter communication

links Cheaper solution

Page 14: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 14

IEC 61850 enabled MV Primary switchgearUniGear Pro

Global Tendering Tool for Air-insulated UniGear panels

Page 15: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 15

IEC 61850 enabled MV Primary switchgearIED Communication Protocol and Media

3. Select IED Communication protocol• IEC61850 Single + GOOSE• IEC61850 Ring (Self-healing) + GOOSE• IEC61850 Ring (HSR) + GOOSE• IEC61850 Double (PRP) + GOOSE• IEC61850 Single• IEC61850 Ring (Self-healing)• IEC61850 Ring (HSR)• IEC61850 Double (PRP)

4. Select Communication media• Galvanic (RJ45)• Optic Glass Fiber

1. Open Switchgeardata window

2. Select tab Control

Page 16: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 16

3. Select sub-tabRelays

2. Select tabFunctional unit

1. Open Paneldata window

4. Press Add button

IEC 61850 enabled MV Primary switchgearIntelligent Electronic Device (Relay)

5. Select Relay Applied filters• Communication protocol• Communication medium

6. Press OK button

Page 17: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 17

IEC 61850 enabled MV Primary switchgearEthernet Switches

1. Open Switchgear data or Panel data window

2. Select tab Additional articles

3. Select TypeCommunications

4. Select MakeABB …

5. Select VariantEthernet Switches

6. Select Type of Ethernet Switch

7. Press Add button

Page 18: IEC 61850 enabled  UniGear

© ABB GroupApril 22, 2023 | Slide 18

IEC 61850 enabled MV Primary switchgearCommunication cables (Patchcords)

1. Open Switchgear data or Panel data window

3. Select sub-tab Additional articles

4. Select TypeCommunications

5. Select MakeMiscellaneous

6. Select VariantPatchcords

7. Select Type of Patchcord

8. Press Add button

2. Select tab Functional unit