IDT MeshI/O · PDF filelink inductive loops, ThermiCam, RADIX magnetometer or similar...

2
ID T ID T MeshI/O TM wire-free detector linking MeshI/O™ is a system to transmit digital signals wirelessly. Based on IDT’s market-leading iMesh™ technology, MeshI/O provides an easy way to connect multiple remote, digital devices where cabling is not readily available or ducting is prohibitvely expensive. MeshI/O was developed to connect vehicle detectors to a downstream junction signal controller. A single upstream MeshI/O unit will support up to 6 digital inputs from inductive loops or other devices such as TrafiCam ® and Heimdall detectors. A second MeshI/O unit installed at the controller end of the link converts the wireless transmission to a digital output and provides screw terminals for connection to a Controller. Benefits and features Fully bi-directional Latency of just 3mS Compatible with any detector which has relay/opto-isolated/switched outputs Supports up to 6 inputs PLUS 6 outputs per end In-built fault detection sets UTC’s controller fault bit in the event of a dropped link Fully compatible with existing iMesh networks Can simultaneously provide mid-span mesh repeater function Avoids the need for expensive ducting OTU meshI/O (controller end) meshI/O (remote end) (containing iMesh router, 6 channels of digital inputs plus 6 channels of digital outputs, power supplies and antenna) Passive antenna Inductive loops (or any other detector with relay or opto-isolated outputs) (containing iMesh router, 6 channels of digital inputs plus 6 channels of digital outputs, power supplies and antenna) bi-directional iMesh wireless link

Transcript of IDT MeshI/O · PDF filelink inductive loops, ThermiCam, RADIX magnetometer or similar...

Page 1: IDT MeshI/O · PDF filelink inductive loops, ThermiCam, RADIX magnetometer or similar detectors on multiple approaches to a junction controller Example applications

IDTIDT MeshI/OTM

wire-free detector linking

MeshI/O™ is a system to transmit digital signals wirelessly.

Based on IDT’s market-leading iMesh™ technology, MeshI/O provides an easy

way to connect multiple remote, digital devices where cabling is not readily

available or ducting is prohibitvely expensive.

MeshI/O was developed to connect vehicle detectors to a downstream junction

signal controller. A single upstream MeshI/O unit will support up to 6 digital

inputs from inductive loops or other devices such as TrafiCam® and Heimdall

detectors.

A second MeshI/O unit installed at the controller end of the link converts the

wireless transmission to a digital output and provides screw terminals for

connection to a Controller.

Benefits and features

Fully bi-directional

Latency of just 3mS

Compatible with any detector which has relay/opto-isolated/switched outputs

Supports up to 6 inputs PLUS 6 outputs per end

In-built fault detection sets UTC’s controller fault bit in the event of a dropped link

Fully compatible with existing iMesh networks

Can simultaneously provide mid-span mesh repeater function

Avoids the need for expensive ducting

OTU

meshI/O (controller end)

meshI/O (remote end)(containing iMesh router, 6 channels of digital inputs plus 6 channels of digital outputs, power supplies and antenna)

Passive antenna

Inductive loops (or any other detector with relay or opto-isolated outputs)

(containing iMesh router, 6 channels of digital inputs plus 6 channels of digital outputs, power supplies and antenna)

bi-directional iMesh wireless link

Page 2: IDT MeshI/O · PDF filelink inductive loops, ThermiCam, RADIX magnetometer or similar detectors on multiple approaches to a junction controller Example applications

set a pelican or puffin wirelessly from a traffic signal controller

connect remote car park entrances and exits to a single, central car park occupancy counter

link two traffic signal controllers in a master-slave arrangement

link inductive loops, ThermiCam, RADIX magnetometer or similar detectors on multiple approaches to a junction controller

Example applications

© 2017 Integrated Design Techniques Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice meshIO_3_220317.indd

TrafiCam and Heimdall are the trademarks of their respective owners

For further information on any of IDT’s products or to discuss how they can be used please contact us at:

IDT Ltd, Endurance House, Seventh Avenue, Team Valley, Tyne & Wear, NE11 0EF, United Kingdom

t: +44 (0)191 491 0800 e: [email protected] www.idtuk.com

About IDT

IDT is a leading provider of communication networks for smart cities and intelligent transport systems (ITS). Our iMesh networks delivery secure communications to over 5,500 traffic signal controlled junctions and our iCell routers are in over 2,500 UTMC-compliant variable message signs and other ITS assets.

QoS

Technical Specifications

Wireless Security

Firewall

10/100 MB Auto-switching (RJ-45 connectors)WAN portMDI/MDI-X Auto-switchingStatic IP or DHCP client

Environmental -15 to +70º C 5 – 95% RH IP54

Dimensions 168 x 123 x 44 mm (depth x width x height)

Weight 0.7 Kg

QoS

Internal option

General

Digital Six channels of digital (opto-isolated) inputs and outputs via screw terminals

Outdoor option

Digital Six channels of digital (opto-isolated) inputs and outputs via screw terminals

Dimensions

Weight 0.8 Kg

WPA2 AuthenticationMAC Address Access Control

Hidden SSID

VLAN

Netfilter - rule-based, multizone firewalling with NAT and masqueradePort forwarding

VPN (SSL & IPsec)

Reserved bandwidth and priority by application or IP address

268 x 268 x 86 mm (width x depth x height)with integral 15dBi directional antenna

Power 220Vac or Power over Ethernet

696726928

globalgroupISO 9001 5965

®