Course Introduction

§ IDR-C with IDU-LC Presentation

§ Typical Radio Link Configuration and Specifications

Product Demonstration

§ IDU-LC Indoor Equipment Description

§ IDU-LC Indoor Equipment Installation

§ IDR-C LCT Presentation & Operation

§ ODU Update

Agenda of 1st Day

Page 4: IDR CwIDU LC Presentation Edition2

IDR-C with IDU-LCPresentation

Page 5: IDR CwIDU LC Presentation Edition2

PointPoint--toto--point Microwave Radio Systempoint Microwave Radio System

7 GHz to 38 GHz7 GHz to 38 GHz

INTRALINK IDR-C with IDU-LC

Page 6: IDR CwIDU LC Presentation Edition2

üNMS

• ODU Front End• Modem• Line Interface

Loopback Capability

üFECüATPC

1+0Topology

7 GHz to 38 GHzOperating FrequencyShort / Long HaulLink Haul

• QPSK• 16QAM

Modulation(user configurable through the LCT)

• Up to 16 E1• 1 x 10/100Base-TX Ethernet

Traffic Interfaces

Up to 34 Mbit/sTotal Throughput Capacity(user configurable through the LCT)

Key Features

Page 7: IDR CwIDU LC Presentation Edition2

IDU-LC: the Indoor UnitODU-CHP: the Outdoor UnitIDU-LC: the Indoor Unit

ODU-CHP: the Outdoor Unit

Configuration of a Site

ODU-CHPODU-CHP

IDU-LCIDU-LC

Page 8: IDR CwIDU LC Presentation Edition2

16 x E1 & Fast Ethernet16 x E1 & Fast Ethernet

IDU-LC Models

4 x E14 x E1

Page 9: IDR CwIDU LC Presentation Edition2

37,0 to 39,5IDR-38CHP

21,2 to 23,6IDR-23CHP

17,7 to 19,7IDR-18CHP

14,5 to 15,35IDR-15CHP

12,75 to 13,25IDR-13CHP

7,7 to 8,5IDR-81CHP

7,1 to 7,9IDR-71CHP

Frequency Band (GHz)ODU-CHP Model

Frequency Bands and ODU-CHP Models

Page 10: IDR CwIDU LC Presentation Edition2

Typical Radio LinkConfiguration

Page 11: IDR CwIDU LC Presentation Edition2

Outdoor Unit (ODU-CHP)2

Indoor Unit (IDU-LC)1

1+0 Configuration with Integrated Antenna

2

1

Page 12: IDR CwIDU LC Presentation Edition2

When the antenna diameter isWhen the antenna diameter is 1 ft (0,3 m), 2 ft (0,6 m), 4 ft (1,2 m) or1 ft (0,3 m), 2 ft (0,6 m), 4 ft (1,2 m) or6 ft (1,8 m)6 ft (1,8 m), you can attach the ODU onto the antenna directly, thus, you can attach the ODU onto the antenna directly, thusavoiding theavoiding the waveguidewaveguide expense.expense.

Integrated Antenna

Page 13: IDR CwIDU LC Presentation Edition2

ODU Specifications

Page 14: IDR CwIDU LC Presentation Edition2

ODU Specifications (7 GHz, 8 GHz)

* guaranteed values are 2 dB higher* guaranteed values are 2 dB higher

-92,5

-89,5

-86,5

27

QPSK

-76,0-76,064QAM, 48x2, Channel 28 MHz

-73,0-73,0128QAM, 63x2, Channel 28 MHz

-92,5

-89,5

-86,5

28

QPSK

-88,5

-85,5

-82,5

25

16QAM

-82,0-82,032QAM, 20x2, Channel 14 MHz

-79,0-79,032QAM, 42x2, Channel 28 MHz

-77,0-77,032QAM, 48x2, Channel 28 MHz

-88,5

-85,5

-82,5

26

16QAM

-71,0

23

IDR-71CHP

128QAM

7,1 to 7,9

Value

24

64QAM

25

32QAM

QPSK, 4x2, Channel 7 MHz

QPSK, 8x2, Channel 14 MHz

QPSK, 16x2, Channel 28 MHz

16QAM, 4x2, Channel 3,5 MHz

16QAM, 8x2, Channel 7 MHz

16QAM, 16x2, Channel 14 MHz

-71,0128QAM, STM-1, Channel 28 MHz

dBm,typ.Rx Sensitivity at BER 10-6 *

242322dBmTx Output Power upper

IDR-81CHPODU CHP Model

32QAM

64QAM

128QAMModulation

7,7 to 8,5GHzFrequency of Operation

ValueUnitSpecification

Page 15: IDR CwIDU LC Presentation Edition2

-92,5

-89,5

-86,5

25

QPSK

-76,0-76,064QAM, 48x2, Channel 28 MHz

-73,0-73,0128QAM, 63x2, Channel 28 MHz

-92,5

-89,5

-86,5

25

QPSK

-88,5

-85,5

-82,5

22

16QAM

-88,5

-85,5

-82,5

22

16QAM

-82,0-82,032QAM, 20x2, Channel 14 MHz

-79,0-79,032QAM, 42x2, Channel 28 MHz

-77,0-77,032QAM, 48x2, Channel 28 MHz

20

32QAM

19

64QAM

-71,0

18

IDR-15CHP

128QAM

14,5 to 15,35

Value

-71,0

18

IDR-13CHP

128QAM

12,75 to 13,25

Value

19

64QAM

20

32QAM

QPSK, 4x2, Channel 7 MHz

QPSK, 8x2, Channel 14 MHz

QPSK, 16x2, Channel 28 MHz

16QAM, 4x2, Channel 3,5 MHz

16QAM, 8x2, Channel 7 MHz

16QAM, 16x2, Channel 14 MHz

128QAM, STM-1, Channel 28 MHz

dBm,typ.Rx Sensitivity at BER 10-6 *

dBmTx Output Power upper

ODU CHP Model

Modulation

GHzFrequency of Operation

UnitSpecification

ODU Specifications (13 GHz, 15 GHz)

* guaranteed values are 2 dB higher* guaranteed values are 2 dB higher

Page 16: IDR CwIDU LC Presentation Edition2

ODU Specifications (18 GHz, 23 GHz)

-91,5

-88,5

-85,5

23

QPSK

-75,0-75,564QAM, 48x2, Channel 28 MHz

-72,0-72,5128QAM, 63x2, Channel 28 MHz

-92,0

-89,0

-86,0

24

QPSK

-87,5

-84,5

-81,5

21

16QAM

-88,0

-85,0

-82,0

22

16QAM

-70,0

17

IDR-23CHP

128QAM

21,2 to 23,6

Value

18

64QAM

-81,0

-78,0

-76,0

19

32QAM

-81,532QAM, 20x2, Channel 14 MHz

-78,532QAM, 42x2, Channel 28 MHz

-76,532QAM, 48x2, Channel 28 MHz

-70,5

18

IDR-18CHP

128QAM

17,7 to 19,7

Value

19

64QAM

20

32QAM

QPSK, 4x2, Channel 7 MHz

QPSK, 8x2, Channel 14 MHz

QPSK, 16x2, Channel 28 MHz

16QAM, 4x2, Channel 3,5 MHz

16QAM, 8x2, Channel 7 MHz

16QAM, 16x2, Channel 14 MHz

128QAM, STM-1, Channel 28 MHz

dBm,typ.Rx Sensitivity at BER 10-6 *

dBmTx Output Power upper

ODU CHP Model

Modulation

GHzFrequency of Operation

UnitSpecification

* guaranteed values are 2 dB higher* guaranteed values are 2 dB higher

Page 17: IDR CwIDU LC Presentation Edition2

ODU Specifications (38 GHz)

-73,064QAM, 48x2, Channel 28 MHz

-70,0128QAM, 63x2, Channel 28 MHz

-90,5

-87,5

-84,5

22

QPSK

QPSK, 4x2, Channel 7 MHz

QPSK, 8x2, Channel 14 MHz

QPSK, 16x2, Channel 28 MHz

-86,516QAM, 4x2, Channel 3,5 MHz

-83,516QAM, 8x2, Channel 7 MHz

-80,516QAM, 16x2, Channel 14 MHz

-79,032QAM, 20x2, Channel 14 MHz

-76,032QAM, 42x2, Channel 28 MHz

-74,032QAM, 48x2, Channel 28 MHz

-68,0128QAM, STM-1, Channel 28 MHz

dBm, typ.

Rx Sensitivity at BER 10-6 *

18171615dBmTx Output Power upper

IDR-38CHPODU CHP Model

16QAM

32QAM

64QAM

128QAM

Modulation

37,0 to 39,5GHzFrequency of Operation

ValueUnitSpecification

* guaranteed values are 2 dB higher* guaranteed values are 2 dB higher

Page 18: IDR CwIDU LC Presentation Edition2

IDU-LCIndoor Equipment

Description

Page 19: IDR CwIDU LC Presentation Edition2

IDU-LC Block Diagram

Ethernet Switch

NMS1

NMS2

ETH1(disabled in current vers.)

ETH2

Ethernet to PDHMapper

Main Processor

LineInterface

Unit 1

LineInterface

Unit 2

LineInterface

Unit 3

LineInterface

Unit 4

MUX

E1

1

... E1

4

E1

5

... E1

8

E1

9

... E1

12

E1

13

... E1

16

FPGAI/O

Alarms

2 x RS-232Channels

Handset EOWglueLogic

Framer/ModemDigitalPart

ServiceChannelInterfaceSubunit

CableInterface

Unit

350 MHz Tx IF

ODU

Power SupplyUnit

±6 V dc

+3,3 V dc

+1,8 V dc

+1,2 V dc

-40 V dc to -60 V dc

CONSOLEConnector

DAC Filters ModulatorQuadrature

ADC140 MHz

SAWFilter

De-ModulatorQuadrature

140 MHz Rx IF

Modem Analog Part

CoaxialCable

FLASH RAM RTC

Page 20: IDR CwIDU LC Presentation Edition2

IDU-LC Functional Description

Ethernet to PDHEthernet to PDH MapperMapper: divides the available bandwidth between a: divides the available bandwidth between a10/100Base10/100Base--TX port and 0 to 16 E1 ports.TX port and 0 to 16 E1 ports.

FPGAAt the transmit path, the MUX sub-unit accepts 16 E1s (G.703) tributaries.Data and clock are recovered and converted in NRZ format. Then, the 16tributaries are multiplexed in a single stream together with synchronizationinformation. The rate of the stream is 34368 kbit/s. This stream is thenforwarded to the Framer / Modem / Cable Interface Unit.

At the receive path, the single stream with the above rate, coming from theFramer / Modem / Cable Interface Unit is demultiplexed in the originaltributaries and encoded in G.703 format.

75 ohm unbalanced or 120 ohm (factory default) balanced line impedance isselectable via straps on the board. 120 ohm to 75 ohm conversion panel isprovided on customer’s request.

The capacity can be configured via the LCT from 4 x E1 to 16 x E1 dependingon the customer’s request.

Page 21: IDR CwIDU LC Presentation Edition2

Service Channel Interface SubunitService Channel Interface Subunit: serves the connection of two RS: serves the connection of two RS--232232Service Channels, two 4W telephone lines (EOW addService Channels, two 4W telephone lines (EOW add--onon subcardsubcard required) and arequired) and ahandset for communication with the remote station. Furthermore,handset for communication with the remote station. Furthermore, the Servicethe ServiceChannel Interface subunit provides four user alarms inputs (eithChannel Interface subunit provides four user alarms inputs (either TTL or dryer TTL or drycontacts) and four user alarms relay outputs which can be progracontacts) and four user alarms relay outputs which can be programmed throughmmed throughthe LCT according to the customerthe LCT according to the customer’’s conveniences convenience

TheThe Framer provides:provides:•• Multiplexing of the Service Channels with the data streamMultiplexing of the Service Channels with the data stream•• Error correction and framing overhead addition to the stream (FError correction and framing overhead addition to the stream (Forward Errororward ErrorCorrection code used is ReedCorrection code used is Reed--Solomon)Solomon)

TheThe Modem provides encoding (modulation) of digital information on theprovides encoding (modulation) of digital information on theanalogue carrier at the transmit path and decoding (demodulationanalogue carrier at the transmit path and decoding (demodulation) of digital) of digitalinformation from the received signal at the receive path.information from the received signal at the receive path.

IDU-LC Functional Description, Continued

TheThe Cable Interface Subunit provides multiplexing of the two IF signals,provides multiplexing of the two IF signals, TxTxand Rx in a single coaxial cable via a twoand Rx in a single coaxial cable via a two--way combiner. This cable connectsway combiner. This cable connectsthe modem to the Outdoor Unit (ODU).the modem to the Outdoor Unit (ODU).

Page 22: IDR CwIDU LC Presentation Edition2

IDU-LC Installation & Cabling

Page 23: IDR CwIDU LC Presentation Edition2

15 W typ.

Consumption

3,5 kg483 mm (19”) x 245 mm x 43,6 mm (1U)IDU-LC

Weight (max)Dimensions (W x D x H)Unit

IDU-LC Dimensions and Weight

Page 24: IDR CwIDU LC Presentation Edition2

IDU-LC – Front Panel

Resetbutton

ALMCPULeds:

RJ-11 Handset Receptaclefor Communication

with the Remote Station

AUX 1 Connector (D-Sub 25 Male)for connection of:- Two 4W Telephone Lines- Internal & External Alarms

AUX 2 Connector(D-Sub 25 Female)

for connection of twoRS-232 Service Channels

IDC 68 pin Female Connectorfor Connection of 4 x E1

or 16 x E1 (mixed Ethernet Model)Tributaries

For test purposes only NMS1, NMS2: 10/100 Base-TX Connectorsfor connection of NMS / LCT

and for interconnection with another IDU-LC(daisy chain)

Disabledin currentversion

10/100 Base-TX Connectorfor Ethernet payload traffic

(mixed Ethernet Model)

LFA, BER3, -48VSYNC, BER6, PS

: leds

N-type Female Connectorfor ODU Connection

ON / OFFSwitch

Two pole MalePower

Connectorfor connection

of–48 V dc

power supply

Page 25: IDR CwIDU LC Presentation Edition2

ALM

CPU

On: System general alarm

Blinking: Proper operation of CPU

LFAOn :

One or more of thefollowing occurs:

• The modem isunlocked.

• The transmission or thereception PLL is

unlocked.• Loss of frame

alignment.• The station has locked

into a different linkidentification number to

the one you haveselected through the LCT

Off :The reception pathoperates correctly.

On: The stationpower supply voltagehas been cabled tothe IDU-LC.

BER3 -48V

SYNC BER6 PS

On : The framer and thusthe modem are locked.

On: BER ≥ 10-6

OFF: BER < 10-6

On: The IDU-LC isproperly powersupplied.

NOTEThe -48 V dc led is ONeven if the ON-OFFswitch is in the OFFposition.

On or Off: CPU problem

IDU-LC – Front Panel Leds

Page 26: IDR CwIDU LC Presentation Edition2

IDU-LC – Front Panel Leds Detail

Green led, if ON, the Ethernet electricallink is up. If blinking, there is data traffic inthe Ethernet electrical link.

Not used

Page 27: IDR CwIDU LC Presentation Edition2

IDU-LC – Front Panel Leds at Unit Start-up

During unit start-up (after installation), the following occur:

1. The Ethernet leds start to blink in a circular mode.

2. The CPU led blinks slowly for ~ 2 s, fast for ~ 10 s during FPGAcode download and finally ends to constant slow blinking.

3. The LFA, SYNC, BER3 and BER6 leds remain OFF until thecompletion of the FPGA bin file download. Then, the state (ON orOFF) of the leds depends on the Modem state.

Page 28: IDR CwIDU LC Presentation Edition2

IDU-LC Installation

1

2

331 2

Page 29: IDR CwIDU LC Presentation Edition2

IDU-LC Grounding

M5 x 10 screw(provided, screwed

on the right sidepanel of the unit)

Grounding Cable, 6 mm2, stranded,PVC, green / yellow, 450 V,

provided at the requested length

Page 30: IDR CwIDU LC Presentation Edition2

E1 Tributaries Cables (120 Ω)

Cable for connection of 120 Ω Ε1Tributaries, IDC 68 pin maleconnector, open end (32 pairs xAWG26)

Page 31: IDR CwIDU LC Presentation Edition2

E1 Tributaries Cables (75 Ω)

IDC (120 Ω) to BNC (75 Ω) Conversion Panel

InterconnectionInterconnectionCableCable

IDU-LC

Available lengths:• 0,5 m• 3 m

Page 32: IDR CwIDU LC Presentation Edition2

Power Supply Cable

•• The IDUThe IDU--LC operates only onLC operates only onnegative power supply,negative power supply,fromfrom ––40 V dc to40 V dc to ––60 V dc60 V dc..

•• The positive pole of the powerThe positive pole of the powersupply source at the IDUsupply source at the IDU--LCLCstation should be grounded.station should be grounded.

•• The recommended value forThe recommended value forthe fuse of the power supplythe fuse of the power supplysource at the IDUsource at the IDU--LC station isLC station is10 A.10 A.

Do notDo not connect the powerconnect the powersupply to the IDUsupply to the IDU--LC beforeLC beforeyou make sure that theyou make sure that thepositive pole of the powerpositive pole of the powersupply source at the IDUsupply source at the IDU--LC station is grounded.LC station is grounded.

(+Vin/GND)

(-Vin)

12

BLUE

BROWN

21

6 mm

10 mm

Heat-shrinkableTube

Make sure thescrews on theconnector top arevisible.

Do notDo not applyapplyforce whenforce whenplugging theplugging thecable. The cablecable. The cablecan be insertedcan be insertedonly in oneonly in onedirection.direction.

-48 V +48 V (GND)

Page 33: IDR CwIDU LC Presentation Edition2

RG-142 Tail Cable

NN--type female fortype female forconnection toconnection tothe IF cablethe IF cablecoming from thecoming from theODUODU

NN--type, male,type, male,R/A forR/A forconnectionconnectionto the IDUto the IDU--LCLC

Page 34: IDR CwIDU LC Presentation Edition2

IDR-C LCT Presentation &Operation

Page 35: IDR CwIDU LC Presentation Edition2

System tab

Informationfor ODU A(HomeConfig,RemoteConfig)

Your PCClock

IDR-CClock

Set andenable the

ATPC

SystemGeneral

Information(Home

Config,RemoteConfig)

Opticalindications of

user alarmsI/O

RF linkperformance

RemoteStation

IP Address

LocalStation

IP Address

Click to getconnected

IP address of the station

Tabs

Menu Bar

Page 36: IDR CwIDU LC Presentation Edition2

IDR View tab

MUX

OutdoorUnits

Tabs

Framer/Modem/CableInterfaceUnit

UserInputs/Outputs

RemoteStation

ODU

ODULoopback

HomeStation

ODU

Mute ODU

DigitalLoopback

ODUReception

level

PowerSupply

Unit

Ethernet toPDH Mapperand PDHMultiplexer

Page 37: IDR CwIDU LC Presentation Edition2

Mixed Ethernet tab – Ethernet Data tab

EthernetData tab

Select themode and rate

ofcommunication

between theIDR-C and the

Ethernet Switch/ Router

Apply thesetting

Option buttons to select the number ofE1 tributaries to be allocated in theMux frame. The remaining timeslots ofthe frame will be allocated to supportthe Ethernet traffic.

Led ONwhen

Ethernetlink withEthernetSwitch /

Router up

EthernetData ofLocalandRemoteStation

Page 38: IDR CwIDU LC Presentation Edition2

Mixed Ethernet tab – MUX Data tab

MUXAlarms

Enables the AIS transmissionat the tributaries outputs

MUXs of Local andRemote Station

Page 39: IDR CwIDU LC Presentation Edition2

Mixed Ethernet tab – Tributaries Data tab

TributariesAlarms

DeactivatesLOS alarm forunconnected

tributaries

RadioLoopback Line

Loopback

Page 40: IDR CwIDU LC Presentation Edition2

Power Supply tab

Power Supply Alarms

Local and RemoteStation PSUs

Page 41: IDR CwIDU LC Presentation Edition2

Modem tab

Set the LinkIdentification

Number

Digital Loopback

Impose SinCos Modulation(for test purposes only)

Framer/Modem/Cable Interface Unit Alarms

Local and Remote StationModems

Page 42: IDR CwIDU LC Presentation Edition2

ODU tab

Radio MeasurementsMute ODU

ODU Loopback

Select the RSSIAlarm

ThresholdSelect the ODU Temperature Alarm Threshold

Clickto modify

Click to apply

Selectthe

transmittedpower

Selectthe RF

channelnumber

Reset ODU

ODUAlarms

ODUinformation

Local and RemoteStation ODUs

Page 43: IDR CwIDU LC Presentation Edition2

Alarm Log tab

Alarm CountNumber

Time and daythe alarm was

generated(according to

the IDR-Cclock) ON: alarm enabled

OFF: alarm disabled

Alarm severity

Alarm polarity

Alarm input/outputat the AUX connector

Alarm name

Page 44: IDR CwIDU LC Presentation Edition2

Versions tab

ODUfirmwareversion

System.ini file

Version of theCMS bin file

Page 45: IDR CwIDU LC Presentation Edition2

The system files are stored in the main memory of the IDU-LC.

System Files

NOTE You are recommended to treat the system files with extreme care and onlywhen required!

Example: lc010014.bin

lcxxx.bin : Microprocessor bin fileContains the IDR-C firmware

version number

NOTE If you delete the file from the memory, the microprocessor will run in bootmode using the default boot code bin file.

Page 46: IDR CwIDU LC Presentation Edition2

Print-out example of the file:

lcboot.sys: Text file, informs the microprocessor:-which lcxxx.bin file version to use-which xxx.bin (FPGA bin file) to download to FPGA-which xxx.ini file (initialization file) to download to FPGA

NOTEAt the power up of the IDU-LC, the microprocessor boots with the defaultbin file, then reads the lcboot.sys file and starts working with the lcxxx.binfile referred in the lcboot.sys file.

System Files, Continued

Page 47: IDR CwIDU LC Presentation Edition2

xxx.ini:Text file, initializes avariety of FPGAfunctionsparameters

The ini files:

qam16_16x2v17.iniqpsk_16x2v01.iniqam16_8x2v01.iniqpsk_8x2v01.iniqam16_4x2v01.iniqpsk_4x2v02.ini

NOTE The filename denotes the modulation, capacity and file version.

qam16_4x2v01.ini

Modulation

Capacity

System Files, Continued

Fileversion

Page 48: IDR CwIDU LC Presentation Edition2

vxx.bin FPGA bin file: FPGA programmingfile

The bin files:

qam16_16x2vxx.binqpsk_ 16x2vxx.binqam16_8x2vxx.binqpsk_ 8x2vxx.binqam16_4x2vxx.binqpsk_ 4x2vxx.bin

NOTEThe filename contains information concerning the modulation and capacity.

qam16_4x2vxx.bin

ModulationCapacity

version number

System Files, Continued

Page 49: IDR CwIDU LC Presentation Edition2

Print-out example of the file:

lcconfig.sys: Text file, informs the microprocessor of the desiredsystem configuration (equipment IP address and SubnetMask, xxx.bin file, xxx.ini file and other importantinformation)

NOTEIf an error occurs during a new system file download, the IDU-LC enters in bootmode with IP address the one stated in the lcconfig.sys file or IP address192.168.50.1 in case the lcconfig.sys file does not exist.

System Files, Continued

Page 50: IDR CwIDU LC Presentation Edition2

System Files, Continued

alrm.nme &alrm.attr:

Two files informing the microprocessor of the alarmsattributes (name, severity, polarity etc.)

idr_cvx.x.mib: MIB file (Management Information Base) for the systemSNMP management

Page 51: IDR CwIDU LC Presentation Edition2

Getting Started – Step 1

Step 1: Install the management application (IDR-C MASTER) in the LCTfrom the IDR-C Operation CD-ROM.

Click here

Page 52: IDR CwIDU LC Presentation Edition2

Getting Started – Step 2

Step 2: Connect the LCT to the IDU-LC.

Connect the LCT to NMS1 or NMS2.

Page 53: IDR CwIDU LC Presentation Edition2

Getting Started – Step 3

Step 3: Assign an IP address to the LCT.

Why assign an IPaddress to the

LCT?

You must assign an IP address to the LCTto enable the communication between theLCT and the home or remote station.

Page 54: IDR CwIDU LC Presentation Edition2

Getting Started – Step 3, Continued

1. For Windows 2000, select Start > Settings > Network and Dial-up Connections > Local AreaConnection. For Windows XP, select Start > Connect to > Show all connections.

2. For Windows 2000, in the window that appears, click Properties.For Windows XP, right-click the Local Area Connection and select Properties.

Page 55: IDR CwIDU LC Presentation Edition2

Getting Started – Step 3, Continued

3. Verify that the Internet Protocol (TCP/IP) check box is selected and click Properties.

Page 56: IDR CwIDU LC Presentation Edition2

Getting Started – Step 3, Continued

4. Click the Use the following IP address optionbutton. In the Default gateway box, type the IPaddress of the IDU-LC. In the IP address box,type the IP address of the IDU-LC increased byone. In the Subnet mask box, type255.255.255.xxx where xxx depends on thenetwork topology (in the example screenshot thexxx value is 252).

The option button Use the following DSN serveraddresses is automatically selected. Leave thesetext boxes empty.

NOTE The manufacturer provides the IDU-LC units of a link with 192.168.59.45 and192.168.59.49 as the default IP addresses.

5. Click OK to close and save the settings.6. Reboot the LCT to activate the settings.7. To confirm that the LCT is communicating withthe IDU-LC, in the Command Prompt window, typeping 192.168.59.45

Page 57: IDR CwIDU LC Presentation Edition2

Getting Started – Step 4

Step 4: Launch the MBR software tool.

Why use the MBRtool?

Use the MBR software tool for:

• Station firmware upgrade

• Station IP address modification

• Station capacity and modulationmodification

Prerequisite: The IDR_LC_REL_xx_xx_xx_Conf.zip file is required.

xx_xx_xx is the file version

Conf can be one of the following dependingon the IDU-LC model:

- MIXED for the 16 x 2 mixed Ethernet model- 4x2 for the 4 x 2 model- E3 for the E3 model- Ethernet for the Ethernet model

The file exists in the IDR-C OperationCD-ROM. In case you do not have theCD-ROM, request the file from themanufacturer.

Conf field appears for xx_xx_xxversion 1_0_18 and then.

Page 58: IDR CwIDU LC Presentation Edition2

Getting Started – Step 4, Continued

1. Extract in the PC hard drive all the files compressed in the IDR_LC_REL_xx_xx_xx_Conf.zipfile for xx_xx_xx version 1_0_18 and then (or IDR_LC_REL_xx_xx_xx.zip file for previousversions) making sure you have selected the Use folder names check box to preserve thefolders structure after the zip extraction.

2. Launch the MBR Tool (MBR.exe file in the lct folder).

Page 59: IDR CwIDU LC Presentation Edition2

Getting Started – Step 5

Step 5: Upgrade the IDR-C firmware.

1. Launch the MBR Tool.

2. Right-click in the Management Treewindow and select Add New System.

3. Right-click on 000.000.000.000 andselect Rename System.

Page 60: IDR CwIDU LC Presentation Edition2

Getting Started – Step 5, Continued

4. Type the IP address of the station whose firmware you want to upgrade.

5. In the FTP Authentication group-box, type nick and nman in the User ID andPassword boxes for both Local and Remote Station and click Connect.

Page 61: IDR CwIDU LC Presentation Edition2

Getting Started – Step 5, Continued

6. In the Management Tree window, right-click on the node whose firmware youwant to upgrade and select Upgrade.

7. In the Wizard window that appears, click Next.

Page 62: IDR CwIDU LC Presentation Edition2

8. Click Browse to find the version_control_file.txt. The file is found in the folderyou have extracted the most recent IDR_LC_REL_xx_xx_xx_Conf.zip file.

Getting Started – Step 5, Continued

9. Open the version_control_file.txt file. In the window that appears, click Next.

Page 63: IDR CwIDU LC Presentation Edition2

Getting Started – Step 5, Continued

10. In the window that appears, select theDelete previous bin, mib, ini files of theremote system and click Next.

The application automaticallyselects the check boxes of thefiles that need upgrading.

NOTE

11. When the upgrading is completed, clickFinish. Repeat steps 6 to 10 to upgradethe remote station firmware.

Do not forget to reset bothlocal and remote stations!

NOTE

Page 64: IDR CwIDU LC Presentation Edition2

Getting Started – Step 6

Step 6: Change the IP Address and Capacity / Modulation of your Station

1. Launch the MBR Tool.

2. Click Find.

3. Enter the user id and password (nick,nman).

4. Expand the node of the station whoseIP address and capacity / modulation youwant to change and then expand theBaseband node.

Page 65: IDR CwIDU LC Presentation Edition2

Getting Started – Step 6, Continued

5. In the Baseband window, click Update to refresh the contents of the window, changethe IP address, the capacity and modulation and then click Apply.

Type thenew IPaddressof thestation.

Select thecapacityandmodulationyou wish.

6. Repeat for the Remote Station.

Do not forget to reset both local and remote stations as well as the ODUs!NOTE

Page 66: IDR CwIDU LC Presentation Edition2

Getting Started – Step 7

Step 7: Launch the IDR-C MASTER.

To launch the IDR-C MASTER, double-click the icon:

The Main Window of the application appears:

LCT_IDR_Cxxx.exe

Page 67: IDR CwIDU LC Presentation Edition2

Getting Started – Step 8

Step 8: Get connected to the IDR-C you want to configure.

When you getconnected:

2. Select or type the IPaddress of IDR-C you wantto get connected.

3. Click Connect.

1. Open the System tabbed sheet.

Page 68: IDR CwIDU LC Presentation Edition2

Getting Started – Step 9

Step 9: On the System menu, select Sys Restart, Remote to reset the remote station andthen Sys Restart, Local to reset the local station. The reset of the stations is recommendedafter the firmware upgrade.

Page 69: IDR CwIDU LC Presentation Edition2

Getting Started – Step 10

Step 10: If you have changed the stations capacity / modulation, you must reset theODUs. Open the ODU tabbed sheet, then open the Remote ODU A tabbed sheet and clickReset ODU. Then open the Local ODU A tabbed sheet and click Reset ODU.

Page 70: IDR CwIDU LC Presentation Edition2

Getting Started – Step 11

Step 11: Set the IDR-C clock.

In the status bar, the System Time becomes equal to the PC Time.=

Click Set Time

Page 71: IDR CwIDU LC Presentation Edition2

IP & Mask Calculation Methodfor INTRALINK Networks

Page 72: IDR CwIDU LC Presentation Edition2

IP & Mask Calculation Method for INTRALINK Networks

The IDR-C IP addressing is in compliance with RIPv2.

N = 256 / nFormula

n : the maximum number of Hosts that can belong to the same Sub-network

n = INTRALINK Systems + 2

n can take one of the values: 4, 8, 16, 32, 64, 128

N: the maximum number of Sub-networks that can be created for the specific number ofHosts

NOTE

Page 73: IDR CwIDU LC Presentation Edition2

IP Address Calculation Method

256255.255.255.0/241

128255.255.255.128/252

64255.255.255.192/264

32255.255.255.224/278

16255.255.255.240/2816

8255.255.255.248/2932

4255.255.255.252/3064

nSubnet MaskN

See nextpage

example

Page 74: IDR CwIDU LC Presentation Edition2

IP Address Calculation Method, Continued

Example

n = 64INTRALINK Systems = 62

N = 256 / 64 = 4

192.168.66.255192.168.66.254192.168.66.193192.168.66.192

192.168.66.191192.168.66.190192.168.66.129192.168.66.128

192.168.66.127192.168.66.126192.168.66.65192.168.66.64

192.168.66.63192.168.66.62192.168.66.1192.168.66.0

tofrom

BroadcastAddress

INTRALINK SYSTEMSAddressesSub-network

Address

N = 4

n = 64

The valuesin thesethree fieldsarehypothetical

Subnet Mask = 255.255.255.192

Page 75: IDR CwIDU LC Presentation Edition2

IP Address Calculation Method, Continued

192.168.66.1

192.168.66.65

IDR-C192.168.66.2

IDR-C

192.168.66.66

IDR-C

192.168.66.3IDR-C

192.168.66.80

IDR-C192.168.66.16

IDR-C

RouterRF Link

Ethernet Link

Sub-network 1IP Address = 192.168.66.0

Subnet Mask = 255.255.255.192

Sub-network 2IP Address = 192.168.66.64

Subnet Mask = 255.255.255.192

IP NetworkLocalCraft

Terminal

Page 76: IDR CwIDU LC Presentation Edition2

Finding outthe IP Address of a Station

Page 77: IDR CwIDU LC Presentation Edition2

Finding out the IP Address of a Station

To find the IP address of the station, reduce the IPaddress of your LCT by one. In the example, the IPaddress of the station is 192.168.59.37

4

In the Open box, type command (Windows 2000 or XP). Inthe DOS prompt, type ipconfig. You view the IP address ofyour LCT.

3

Select Start>Run.2

Double-click on the icon of the dial-up connection that youcreated for the communication of your LCT with the IDR-C.1

ActionStep

In case you do not know the IP address of the IDU-LC you want to get connected to, followthe procedure below or use one of the relevant free Internet utilities.

NOTE

Before proceeding to theprocedure, you should connectthe LCT to the CONSOLE PORT(RS-232 port) of the IDU-LC andcreate a dial-up connectionbetween your LCT and theIDR-C.

IDR-C CD-ROM: AutomaticInstallation through Wizard

Page 78: IDR CwIDU LC Presentation Edition2

ODU Update

Page 79: IDR CwIDU LC Presentation Edition2

Updating the ODU Version

11. Use the FTP Tool and download the oduvxxx_chk.bin file (provided by themanufacturer) to the IDU-LC.

FTP Tool of the ApplicationFTP Tool of the Application

1.1. On the SystemOn the Systemmenu, selectmenu, select FTP ToolFTP Tool..

Page 80: IDR CwIDU LC Presentation Edition2

2.2. Type the IP addressType the IP addressof the IDRof the IDR--C.C.

3.3. Click to getClick to getconnected.connected.

4.4. Select theSelect theoduvxxx_chk.binfile.

5.5. Click toClick todownload todownload toIDUIDU--LC.LC.

Updating the ODU Version, Continued

Page 81: IDR CwIDU LC Presentation Edition2

2.2. Select Start>Run and in the Open box, type telnet <ip address> where <ipaddress> is the ip address of the IDR-C station whose the ODU version you want toupdate (Login: nick, Password:(Login: nick, Password: nmannman).).

33. Type this commandand press ENTER.

The ODU update process lasts about 1 or 2 minutes. After the proThe ODU update process lasts about 1 or 2 minutes. After the process completion,cess completion,the following message appears:the following message appears:

Updating the ODU Version, Continued

Page 82: IDR CwIDU LC Presentation Edition2

Changing the ODU RF Channels

If you want an RF channel arrangement other than the one describIf you want an RF channel arrangement other than the one described in the ITUed in the ITU--RRRecommendation that corresponds to your operating frequency bandRecommendation that corresponds to your operating frequency band, you should, you shouldupdate theupdate the ODUODU xxxxxx..chschs file.file.

1. Use the FTP Tool and download the new xxx.chs provided by themanufacturer to the IDU-LC.

2. Select Start>Run and in the Open box, type telnet <ip address> where<ip address> is the ip address of the IDR-C station whose the ODUxxx.chs file you want to update (Login: nick, Password:(Login: nick, Password: nmannman))

3. Type ODUupdate xxx.chs and press ENTER. The ODU update processlasts a few seconds.

4. Open the ODU tabbed sheet and click Reset ODU to reset the ODU.

Page 83: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C

Page 84: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 1

Step 1: Set the transmission/reception channel.

Before setting the transmission/reception channel, open the System tabbed sheet,click Home Config and check if the Channel Step value is half the Channel Sizevalue.

If so, select the RF Channels Numbers as follows: 1, 3, 5, 7 etc. or 2, 4, 6, 8 etc.depending on the desired transmission frequency to avoid the existence ofcommon frequencies between two different RF Channels Numbers!

Page 85: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 1, Continued

1. Select the ODU

2. Click EDIT3. Select the numberof the RFtransmission andreception channel.

Step 1: Set the transmission/reception channel.

4. Click COPY toapply the setting

Page 86: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 2

Step 2: Set the transmitted power

1. Select the ODU

2. Click EDIT

3. Select thetransmitted power

4. Click COPY toapply the setting

Page 87: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 3

Step 3: Set the link identification number

2. Select the link idyou want in therange 0 to 15.

The link identificationnumber is a number inthe range 0 to 15 theoperator selects throughthe LCT to identify in aunique way a linkbetween a local and aremote IDR-C. The linkidentification numberis extremely useful incases of multiple linksexisting between twostations as it preventsthe stations fromdemodulating databelonging to some otherlink if , by mistake, thestations lock into thefrequency of this link.

1. Click REMOTE A.

3. Click.

4. Click LOCAL A and repeat steps2 and 3 to set the same id.

5. Click Enable so that, in case the linkid of the remote IDR-C is other than thelink id of the local IDR-C, an AIS alarm isenabled at the tributaries outputs. Theled beside the Enable button becomesyellow.

Page 88: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 4

Step 4: Save the configuration you made

Page 89: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 5 & 6

Step 5: Repeat steps 1 to 4 for the remote station

Step 6: Align the antennas of the two stations

Page 90: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 7

Step 7: After the establishment of the link between the two stations, proceed to theoptimization of the link to achieve max RSSI level

To achieve reliable transmission in a microwave link, the transmitted power plus thegain of the transmitter and receiver antennas should exceed the attenuation at thetransmission path and the sensitivity of the receiver. The attenuation at thetransmission path is given in the following formula:

A=92.4+20logD+20logF

A is the attenuation at the transmission path in dBD is the distance between the antennas in kmF is the frequency of the microwave signal in GHz

Page 91: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 7, Continued

Check the receptionlevel in the Rx In

box.

To optimize the link, while performing minor horizontal and vertical movements of theantenna, open the ODU tabbed sheet and check the reception level in the Rx In box in theRadio Measurements group box.

Prerequisites: If you use the LCT to observe the reception level or the RSSI, you will needanother person to move the antenna.

Page 92: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 7, Continued

1

Remove the cover from receptacle 1 shown in thefigure and connect a digital voltmeter using thespecial cable provided.

In case no second person is available to move the antenna, you can use the special cable tomeasure the RSSI level.

Page 93: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 8

1. Select the ODU

2. Click EDIT

3. Select thethreshold 4. Click COPY to

apply the setting

Step 8: Set the RSSI Alarm Threshold (optional)

The led becomesred if the receptionlevel falls below thethreshold you set

Page 94: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 9Step 9: Set the ODU Temperature Alarm Threshold (optional)

1. Select the ODU

2. Click EDIT

3. Select thethreshold

4. Click COPY toapply the setting

The led becomesred if the internaltemperature of ODUexceeds thethreshold you set

The internaltemperature of ODUis ~ 25 °C to +30 °Chigher than theenvironmentaltemperature. TheODU can workproperly at anenvironmentaltemperature range-45 °C to +90 °C.The applicationpermits you to setan uppertemperaturethreshold. If theinternal temperatureof the ODU exceedsthis threshold, analarm will begenerated.

Page 95: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 10Step 10: Open the System tabbed sheet and confirm the linksettings for both the local and the remote station

Page 96: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 11Step 11: Set the ATPC level and enable the ATPC feature (optional)

1. Click RemoteConfig.

When you enable the ATPC(Automatic TransmissionPower Control) feature,you make the transmitter atthe local station adjust itsoutput power so that thereceiver at the remotestation constantly receivesthe desired level you haveset.

2. Select the desiredreception level of theremote station.

3. Click EnableATPC to enable theATPC feature.Notice the led turnsON.

Page 97: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Step 12Step 12: Allocate the E1 traffic and the Ethernet traffic in the Muxframe

1. Click Local.

2. Select the mode and rate of communicationbetween the IDR-C and the Ethernet Switch /Router. The settings of the Ethernet Switch /Router and the IDR-C must be the same.

5. Click the appropriate option buttonaccording to the desirable number of E1tributaries to be allocated in the Mux frame.The remaining timeslots of the frame will beallocated to support the Ethernet traffic.

NOTE You must make the setting whether you have mixed Ethernet traffic or not!

Open theMixed

Ethernettabbed

sheet andthen the

EthernetData

tabbedsheet.

3. Click to apply thesetting.

4. The led turns on when the Ethernet link with theEthernet Switch / Router is up.

6. Click to apply thesetting.

7. ClickRemoteand repeatsteps 2,3,4,5 and 6.

Page 98: IDR CwIDU LC Presentation Edition2

Configuring the IDR-C – Steps 13, 14,15

Step 13: Open the different tabbed sheets and check if there are any alarm signals.

Step 14: Save the modifications you made for both Home and Remote Stations.

Step 15: Close the application.

You have now completed the configuration of theIDR-C. The link is ready to operate.

Page 99: IDR CwIDU LC Presentation Edition2

IDR-C Radio LinkOperation and Maintenance

Page 100: IDR CwIDU LC Presentation Edition2

Open the System tabbed sheet and click Home Config or Remote Config.

Click Home Configor

Remote Config

Monitoring the IDR-C Configuration

Page 101: IDR CwIDU LC Presentation Edition2

UNPROTECTED:1+0 topology

Select the ATPCreception level ofremote station

The transmissionband (High orLow) of ODU

The frequency inwhich the ODU istransmitting atthis moment

The allowed rangeof ODU outputpower

The start frequencyof the ODUtransmission band

The RF channelbandwidth

How many kHz existbetween twosuccessive RFchannel numbers

Monitoring the IDR-C Configuration, Continued

Page 102: IDR CwIDU LC Presentation Edition2

Open the ODU tabbed sheet.Select the ODUyou want tomonitor

Monitoring the ODU

Page 103: IDR CwIDU LC Presentation Edition2

Radio Measurements

Tx IF signalpower

ODU receptionlevel

Transmissionpower

Temperatureinside ODU

Output voltagesof ODU internalpower supplyunits

Monitoring the ODU, Continued

Page 104: IDR CwIDU LC Presentation Edition2

ODU serial number

ODU identificationnumber

Central frequencyof duplexertransmission filterCentral frequency

of duplexerreception filter

Duplexerbandwidth

Duplexerbandwidth margin(the marginbetween duplexerbandwidth startfrequency andduplexer first fc

For manufactureruse only

Other ODU information

Monitoring the ODU, Continued

Page 105: IDR CwIDU LC Presentation Edition2

Open the Versions tabbed sheet.

LCTapplicationversion

ODUfirmwareversion

Not used

Version of theMicroprocessorbin file

Version of the FPGAbin file

Monitoring the IDR-C Version

Not used

Type of theIDU-LC unit

System.inifile

The code type of theFramer/Modem FPGA

Version of the IDU-LCunit

The Tx IF frequency

Page 106: IDR CwIDU LC Presentation Edition2

Open the IDR View tabbed sheet.

Monitoring the IDR-C Alarms

Page 107: IDR CwIDU LC Presentation Edition2

Not used

PSU

UserInputs/Outputs

Framer/Modem/CableInterface Unit

IDU of Remote Station

Red block indicates detection of alarm. Open the corresponding tabbed sheet toview the alarms detected.

Monitoring the IDR-C Alarms, Continued

Ethernet toPDH Mapperand PDHMultiplexer

ODU ofRemoteStation

IDU of Home Station

ODU ofHome

Station

NOTE The PS B block although red does not denote an alarm.

Page 108: IDR CwIDU LC Presentation Edition2

Monitoring the ODU Alarms

Open the ODU tabbed sheet.

Page 109: IDR CwIDU LC Presentation Edition2

General Alarms

No RF Signalat the outputof ODU

The reception level falls below athreshold the manufacturer hasset for a reliable RF linkperformance. This thresholddepends on the bit rate and themodulation type according to thetable.

-64STM1128QAM-7316 x 2/E3QPSK-7416 x 2/E316QAM-738 x 2QPSK-778 x 216QAM-764 x 2QPSK-804 x 216QAM

Threshold(dBm)Bit Rate (Mbit/s)Modulation

Monitoring the ODU Alarms, Continued

Page 110: IDR CwIDU LC Presentation Edition2

Threshold Alarms

The reception level fallsbelow the RSSIthreshold you have set

The temperature insidethe ODU exceeds thethreshold you have set

The power of the Tx IFsignal falls below -20 dBm.The +5 V output voltage

of the ODU internalpower supply unit fallsbelow +4,5 V

Monitoring the ODU Alarms, Continued

The +6,5 V outputvoltage of the ODU

internal powersupply unit falls

below +6 V

The -12 V outputvoltage of theODU internal

power supply unitfalls below -11 V

The +12 V outputvoltage of theODU internalpower supply unitfalls below +11 V

Page 111: IDR CwIDU LC Presentation Edition2

Radio Locks AlarmsThe Digit DirectSynthesizer is unlockedwith consequence no RFsignal at the PowerAmplifier output and thegeneration of the PA Outalarm. Contact themanufacturer for ODUreplacement.

The Loop Back Synthesizer isunlocked. This alarm can begenerated during the RFloopback test (ODU LOOPcommand button of the LOCALODU tabbed sheet). The ODULOOP command activates theLoop Back Synthesizer whichloops the Tx signal in the Rxpath.

The Rx Synthesizeris unlocked.

The Tx Synthesizer isunlocked withconsequence no RFsignal at the PowerAmplifier output and thegeneration of the PA Outalarm as well. Contactthe manufacturer forODU replacement.

Monitoring the ODU Alarms, Continued

Page 112: IDR CwIDU LC Presentation Edition2

Open the Modem tabbed sheet.

Monitoring the Framer/Modem/CI Alarms

Page 113: IDR CwIDU LC Presentation Edition2

A hardware error hasoccurred in the Txpath of the Framer. Ifthe problem persists,contact themanufacturer for cardreplacement.

The Rx Synthesizer ofthe Modem is unlocked.

BER ≥ 10-3

BER ≥ 10-6 The Modem cannotdemodulate thecarrier information.

The alignment of theframe has been lost. Hardware error in the card.

Contact the manufacturer forreplacement.The Modem cannot recognize

the Link IdentificationNumber.

Monitoring the Framer/Modem/CI Alarms, Continued

Page 114: IDR CwIDU LC Presentation Edition2

Monitoring the Mux Alarms

Open the Mixed Ethernet tabbed sheet and then the MUX Data tabbed sheet.

Page 115: IDR CwIDU LC Presentation Edition2

The clock coming fromthe Framer/Modem/CIUnit has been lost.

The frame coming fromthe Framer/Modem/CIUnit has been lost.

The remote station cannot receivethe signal transmitted. As aconsequence, the remote stationsends the RAI alarm to the localstation.

Monitoring the Mux Alarms, Continued

Page 116: IDR CwIDU LC Presentation Edition2

Open the Power Supply tabbed sheet.

Monitoring the Power Supply Alarms

Page 117: IDR CwIDU LC Presentation Edition2

There is no inputvoltage at the PowerSupply Unit.

Not used

Monitoring the Power Supply Alarms, Continued

Page 118: IDR CwIDU LC Presentation Edition2

Monitoring the Tributaries/Service Channels Alarms

Open the Mixed Ethernet tabbed sheet and then the Tributaries Data tabbedsheet.

Page 119: IDR CwIDU LC Presentation Edition2

The AIS pattern (allones sequence) isapplied at the specifictributary input.When no AIS is appliedat the input, the opticalindication is green.

There is no signal at thespecific tributary input.

NOTE To monitor the service channels alarms, click the ServiceChannels tab in the Tributaries Data tabbed sheet.

Monitoring the Tributaries/Service Channels Alarms, Continued

Page 120: IDR CwIDU LC Presentation Edition2

Open the System tabbed sheet.

Monitoring the Indications of the User Alarms Inputs and Outputs

Page 121: IDR CwIDU LC Presentation Edition2

The AUX 1 connectorprovides four useralarms inputs and fouruser alarms outputs.

To monitor the indications of the user alarms inputs and outputs, open theSystem tabbed sheet and click Home I/O Status or Remote I/O Statusdepending on which you want to monitor.

Monitoring the Indications of the User Alarms Inputs and Outputs, Continued

Page 122: IDR CwIDU LC Presentation Edition2

You can select to monitor:

• the last 20 alarms

• the last 50 alarms

• all the alarms (up to 999)

Alarm log file = text type file created by the system when you select to monitorthe alarms. The filename is Log_<date>. When you close the managementapplication, the system saves this file in the same folder with the managementapplication.

NOTE Do not delete the alarm log file as the manufacturer may requestit in case of troubleshooting.

Monitoring the History of Alarms

Page 123: IDR CwIDU LC Presentation Edition2

Monitoring the History of Alarms, Continued

NOTEIn case of problems during the alarms history monitoring, makesure the alarms files names in the lcconfig.sys file are thealrm.nme and alrm.attr

Page 124: IDR CwIDU LC Presentation Edition2

On the System menu, point to Alarm log, then point to Activation, and then selectone of the following:

• Last 20 if you want to monitor the last 20 alarms• Last 50 if you want to monitor the last 50 alarms• All if you want to monitor all the alarms (the application can log up to 999

alarms)

Monitoring the History of Alarms, Continued

Page 125: IDR CwIDU LC Presentation Edition2

Alarmcountingnumber. Themost recentalarmappears atthe end of thelist. Up to 999alarms canappear in thelist. Onreceipt of the1000th alarm,the oldestalarm isautomaticallydeleted andthe new alarmappears atthe end of thelist.

Time and day(according tothe IDR-Cclock) the alarmwas generated.

State•ON: enabled alarm•OFF: disabled alarm

Polarity•Normal is the NormalOpen (default). Withthis setting, as soonas an alarm appears atthe input/output pin ofthe AUX 1 connector,the micro-switch inthe internal of thesystem connects thisalarm input/output pinto the alarminput/output GND ofthe connector•Reverse is the NormalClose (….disconnects)The alarm

input/outputat the AUX 1connector

Monitoring the History of Alarms, Continued

Page 126: IDR CwIDU LC Presentation Edition2

1. upload these files from the CMS Unit

2. make the changes you want

3. delete the old files from the CMS Unit

4. download the new files to the CMS Unit

NOTE

The alarms attributes are recorded in the alrm.nme and alrm.attr files stored inthe CMS Unit. If you want to change the alarm attributes, you should:

Although the application gives you the ability to change the alarmsattributes, you are recommended not to do this unless you are anexperienced user.

Changing the Alarms Attributes

Page 127: IDR CwIDU LC Presentation Edition2

1. Create two folders. You will use the one folder to store the currentalrm.nme and alrm.attr files of the CMS unit and the other folder to storethe new alrm.nme and alrm.attr files you will create.

2. On the System menu, select FTP Tool.

Changing the Alarms Attributes, Continued

Page 128: IDR CwIDU LC Presentation Edition2

3. Type the IP address of the IDR-C

4. Click

5. Select the folderwhere you want tomove the alrm.nmeand alrm.attr files

6. Select the alrm.nme file

7. Click

8. Browse the folder to which you want to move the file andclick Save

9. Repeat steps 6, 7 and 8 for the alrm.attr file and then close the FTP Tool.

The Uploading Procedure - FTP Tool

Changing the Alarms Attributes, Continued

Page 129: IDR CwIDU LC Presentation Edition2

On the System menu, point to Alarm Log and then select Alarm Tool.

Changing the Alarms Attributes, Continued

Page 130: IDR CwIDU LC Presentation Edition2

1. SelectOpen toopen thealrm.nmeandalrm.attrfiles

2. Select theappropriate tab.

3. Type the new name ofthe alarm.

4. Select the severity.

5. Select the polarity.6. Select the box ifyou want the alarmto appear at theuser output. 7. Select the box if you want

the alarm to be stored inthe alarm log file and thusappear in the alarmshistory list.

8. Repeat for as manyalarms as needed.

9. Click OK.

Alarm Tool

10. SelectSave andsave the newalrm.nme andalrm.attr filesin the folderyou havecreated tosave the newfiles.

11. Exit the Alarm Tool.

Changing the Alarms Attributes, Continued

Page 131: IDR CwIDU LC Presentation Edition2

1. Type the IPaddress ofthe IDR-C.2. Click.

5. Select the newalrm.nme andalrm.attr files youhave created.

3. Select the alrm.nmeand alrm.attr files.

4. Click

7. Close the FTP Tool.

8. On the System menu, select Sys Restart to activate the new files or pressthe RST button on the front panel of the IDU-LC.

The Downloading Procedure - FTP Tool

6. Click

Changing the Alarms Attributes, Continued

Page 132: IDR CwIDU LC Presentation Edition2

Service Calls

Home Station

Remote Station

PTT Handset

PTT Handset

Point-to-point full duplex communication

Page 133: IDR CwIDU LC Presentation Edition2

Loopbacks

The application gives you the ability to perform the following loopbacks:

• LLOOP: Line Loop (Local and Remote Station)• DLOOP: Digital Loop (Local Station)• ODU LOOP (Local Station)• RLOOP: Radio Loop (Local and Remote Station)

RF Link

LocalODU

LocalMux

LocalFramer/Modem/

CI

LLOOP DLOOPRLOOP ODU LOOP

RemoteODU

RemoteMux

RemoteFramer/Modem/

CI

LLOOPDLOOP RLOOPODU LOOP

Recommended Loopbacks Order 1. LLOOP2. DLOOP3. ODU LOOP4. RLOOP

Loopbacks, Performance Monitoring & Other Tests

Page 134: IDR CwIDU LC Presentation Edition2

Performing the LLOOP

Open theMixedEthernettabbed sheetand then theTributariesData tabbedsheet.

Click toperform theLLOOPloopback

Loopbacks, Performance Monitoring & Other Tests, Continued

Page 135: IDR CwIDU LC Presentation Edition2

Performing the DLOOP

Open the Modem tabbed sheet.

Click toperformthe DLOOPloopback

Loopbacks, Performance Monitoring & Other Tests, Continued

Page 136: IDR CwIDU LC Presentation Edition2

Loopbacks, Performance Monitoring & Other Tests, Continued

Performing the ODU LOOP

Open the ODU tabbed sheet.

NOTE Switch-off the remote station and then proceed to the ODU LOOP!

Click toperform theODU LOOPloopback

Select the ODU

Page 137: IDR CwIDU LC Presentation Edition2

Performing the RLOOPOpen the Mixed Ethernet tabbed sheet and then the Tributaries Data tabbed sheet.

Click toperform theRLOOPloopback

Loopbacks, Performance Monitoring & Other Tests, Continued

Page 138: IDR CwIDU LC Presentation Edition2

Monitoring the Performance of the RF LinkYou can monitor the performance of the RF link by performing the G.826 block erroranalysis test (ITU-T Recommendation G.826: “End-to-end error performanceparameters and objectives for international, constant bit-rate digital paths andconnections”)

Open theSystem tabbedsheet.

Loopbacks, Performance Monitoring & Other Tests, Continued

Page 139: IDR CwIDU LC Presentation Edition2

Monitoring the Performance of the RF Link, Continued

If the Test Running led is on, click STOP TEST and then click START TEST otherwise click STARTTEST. Wait a few milliseconds for the internal error counters to reset. Then the test starts.

Unavailable Time + Available Time

The Available Time (s) starts after 10consecutive non-SES seconds havepassed.

The Unavailable Time (s)starts when 10 consecutiveseverely errored secondshave been detected. These 10seconds are part of theUnavailable Time. If abidirectional path isconsidered, the UnavailableTime is if one or bothdirections are unavailable.

Background Block Error, anerrored block not occurringas part of a SES.

Errored Second,a one-secondperiod with oneor more erroredor lost blocks.

Severely Errored Second,a one-second periodwhich contains ≥ 30 %errored blocks or at leastone defect; one-secondperiod which has a biterror ratio ≥ 10-3 or duringwhich Loss of Signal orAlarm Indication Signal isdetected; SES is a subsetof ES.

Loopbacks, Performance Monitoring & Other Tests, Continued

Page 140: IDR CwIDU LC Presentation Edition2

Enabling the AIS Transmission at the Tributaries Outputs

Open the Mixed Ethernet and thenthe MUX Data tabbed sheet.

Click Toggle AIS to enable (default) / disablethe AIS transmission at the tributaries outputsin case of RF link failure so that if there aresystems connected to the IDR-C, they willcontinue to be synchronized with it.

The led turns on if you have enabled the AIStransmission.

Loopbacks, Performance Monitoring & Other Tests, Continued

Page 141: IDR CwIDU LC Presentation Edition2

Open the Modem tabbed sheet.

Click SinCos to interrupt the QAM or QPSKmodulation and impose the SinCosmodulation. Then you will be able to checkthe central transmission frequency fc duringlaboratory testing.

Imposing SinCos Modulation

Loopbacks, Performance Monitoring & Other Tests, Continued

Page 142: IDR CwIDU LC Presentation Edition2