ICNIRP 6th International Non – Ionizing Radiation Workshop Rio … · 27/10/2008 ICNIRP 6TH 2008...
-
Upload
nguyendung -
Category
Documents
-
view
218 -
download
0
Transcript of ICNIRP 6th International Non – Ionizing Radiation Workshop Rio … · 27/10/2008 ICNIRP 6TH 2008...
27/10/2008 ICNIRP 6TH 2008 1
ICNIRP 6th International Non – Ionizing Radiation WorkshopRio de Janeiro, Brazil, 14-17 October 2008
In Cooperation with the Ministry of Science and Technology of Brazil
Overview of EMF Standards in Latin AmericaCurrent Situation and Policies
6th International NIR Workshop
ICNIRP 6th International Non ICNIRP 6th International Non –– Ionizing Radiation WorkshopIonizing Radiation WorkshopRio de Janeiro, Brazil, 14Rio de Janeiro, Brazil, 14--17 October 200817 October 2008
In Cooperation with the Ministry of Science and Technology of BIn Cooperation with the Ministry of Science and Technology of Brazil razil
Overview of EMF Standards in Latin AmericaOverview of EMF Standards in Latin AmericaCurrent Situation and PoliciesCurrent Situation and Policies
6th International NIR Workshop6th International NIR Workshop
Eng. Jorge Skvarca
Member WHO Panel on
Radiation
Eng. Jorge SkvarcaEng. Jorge Skvarca
Member WHO Panel on Member WHO Panel on
Radiation Radiation
27/10/2008 ICNIRP 6TH 2008 2
International and National Bodies Consultation
International and National Bodies International and National Bodies
ConsultationConsultation
• PAHO - WHO
• ICNIRP
• IEEE
• IARC
• IEC
• NRPB/HPA
• FCC
• FDA
• McLaughlin Centre for Population Health Risk Assess.
•• PAHO PAHO -- WHOWHO
•• ICNIRPICNIRP
•• IEEEIEEE
•• IARCIARC
•• IECIEC
•• NRPB/HPANRPB/HPA
•• FCCFCC
•• FDAFDA
•• McLaughlin Centre for Population Health Risk Assess. McLaughlin Centre for Population Health Risk Assess.
27/10/2008 ICNIRP 6TH 2008 3
EMF National Protection Framework References
EMF National EMF National Protection Framework Protection Framework
ReferencesReferences
• AINSI C-95.1 1979
• AINSI / IEEE 1991
• FCC – AINSI / IEEE 1995
• ICNIRP RF 1988
• ICNIRP Time-varying EMF 0Hz-300GHz 1998
• ITU-T K. 52
• NRPB/HPA - UK
•• AINSI CAINSI C--95.1 197995.1 1979
•• AINSI / IEEE 1991AINSI / IEEE 1991
•• FCC FCC –– AINSI / IEEE 1995AINSI / IEEE 1995
•• ICNIRP RF 1988ICNIRP RF 1988
•• ICNIRP TimeICNIRP Time--varying EMF 0Hzvarying EMF 0Hz--300GHz 1998300GHz 1998
•• ITUITU--T K. 52T K. 52
•• NRPB/HPA NRPB/HPA -- UKUK
27/10/2008 ICNIRP 6TH 2008 4
SHORT HISTORY OF NIR IN LATIN AMERICAN COUNTRIES
• 1971 Radiological Health PAHO – Dr. G. Hanson
• 1976 BRH / CDRH / FDA
• 1981 RPB-SC Canada – Dr. M. Repacholi
• 1982 INDEBIO - Argentina - Dr. A. Portela
27/10/2008 ICNIRP 6TH 2008 5
ICNIRP GUIDELINES
• RF (interim) 1984 • RF 1988
•50 Hz E and B Fields (interim)1990
•Static B Fields 1994
• Time-varying EMF > 0 Hz-300 GHz 1998
27/10/2008 ICNIRP 6TH 2008 6
ICNIRP GUIDELINESMain consultation
• RF (interim) 1984 • RF 1988
•50 Hz E and B Fields (interim)1990
•Static B Fields 1994
• Time-varying EMF > 0 Hz-300 GHz 1998
27/10/2008 ICNIRP 6TH 2008 8
EMFELF and RF
EMFELF and RF
• POWER LINES
• EMF RF SOURCES
TV, RADIO, PC, COMMUNICATIONS, MICROVAWES,
RADARS, INDUSTRY AND MEDICINE.
• MOBIL TELEPHONY AND INTERNET
•• POWER LINESPOWER LINES
•• EMF RF SOURCESEMF RF SOURCES
TV, RADIO, PC, COMMUNICATIONS, MICROVAWES, TV, RADIO, PC, COMMUNICATIONS, MICROVAWES,
RADARS, INDUSTRY AND MEDICINERADARS, INDUSTRY AND MEDICINE..
•• MOBIL TELEPHONY AND INTERNETMOBIL TELEPHONY AND INTERNET
27/10/2008 ICNIRP 6TH 2008 9
EMFOPTICAL RADIATION
EMFOPTICAL RADIATION
• Ultraviolet (UV – A B C )
• Visible
• Infrared (IR)
•• Ultraviolet (UV Ultraviolet (UV –– A B C )A B C )
•• VisibleVisible
•• Infrared (IR)Infrared (IR)
27/10/2008 ICNIRP 6TH 2008 10
LATIN AMERICAN COUNTRIESEMF Regulations
LATIN AMERICAN COUNTRIESLATIN AMERICAN COUNTRIES
EMF RegulationsEMF Regulations
• Argentina Ecuador
• Bolivia Mexico
• Brazil Paraguay
• Chile Peru
• Colombia Venezuela
• Costa Rica Uruguay
•• Argentina Ecuador Argentina Ecuador
•• Bolivia MexicoBolivia Mexico
•• Brazil ParaguayBrazil Paraguay
•• Chile PeruChile Peru
•• Colombia VenezuelaColombia Venezuela
•• Costa Rica UruguayCosta Rica Uruguay
27/10/2008 ICNIRP 6TH 2008 11
EMF NATIONAL PROTECTION FRAMEWORK
Argentina:
1.- Ministry of Health – Res. 202/1995 (100 kHz-300GHz)2.- SeCom (Secretaria de Comunicaciones) - Res. 530/20003.- Ministry of Labor - MTESS Res. 295/20034.- Energy Department ENRE - Res. 77/1998 (ELF - 50 Hz)
27/10/2008 ICNIRP 6TH 2008 14
Sensitive Areas in Buenos Aires Edificio Claxon – Cercanías Hospital Pirovano
27/10/2008 ICNIRP 6TH 2008 16
RF EXPOSURE LIMITS Argentina 1988Enforced by law MS 202/1995-SECOM 530/2000
0.42
0.95
27/10/2008 ICNIRP 6TH 2008 17
EMF NATIONAL PROTECTION FRAMEWORK
Bolivia: SITTEL 0313/2002 – Estandar Tecnico de Superintendencia de Telecomunicaciones (Based on FCC Guidelines) – 300 kHz to 100 GHz
There are no Guidelines for ELF and Optical Radiation.
27/10/2008 ICNIRP 6TH 2008 18
EstEstáándar tndar téécnico en Bolivia ?cnico en Bolivia ?La Superintendencia de Telecomunicaciones mediante ResoluciLa Superintendencia de Telecomunicaciones mediante Resolucióón Administrativa n Administrativa Regulatoria NRegulatoria N°°2002/0313 de fecha 19 de abril de 2002 aprob2002/0313 de fecha 19 de abril de 2002 aprobóó el el ““Estandar TEstandar Téécnico cnico Sobre LSobre Líímites de Exposicimites de Exposicióón Humana a Campos Electromagnn Humana a Campos Electromagnééticosticos”” (basado en (basado en normas de la FCC de EEUU).normas de la FCC de EEUU).
Los niveles de precauciLos niveles de precaucióón que se establecieron fueron los siguientes:n que se establecieron fueron los siguientes:
A partir de esa fecha TODAS las solicitudes de licencia, deben iA partir de esa fecha TODAS las solicitudes de licencia, deben incluir el estudio ncluir el estudio ttéécnico sobre los niveles de intensidad de campo electro de los TXcnico sobre los niveles de intensidad de campo electro de los TX
27/10/2008 ICNIRP 6TH 2008 19
EMF NATIONAL PROTECTION FRAMEWORK
Brazil:
1.- RF ANATEL /Agencia Nacional de Telecomunicaciones, Resolução 303/2002 (Based on ICNIRP) 9 kHz e 300 GHz.
2.- ELF SFE/ Superintendencia de Fiscalização dos Serviços de Eletricidade – Manual 2004
27/10/2008 ICNIRP 6TH 2008 20
EMF NATIONAL PROTECTION FRAMEWORK
Chile: 1.- Decreto 594/00 Salud - SUBATEL N 505/00 435 microW/cm2 for 800 and 1900 MHz
2.- Res. Exenta 403/2008 – 400 MHz to 2200 MHz(Mainly based on ICNIRP) - Only for Public
27/10/2008 ICNIRP 6TH 2008 21
EMF NATIONAL PROTECTION FRAMEWORK
Colombia:
1.- Diario Oficial 45.808 Norma Técnica Decreto 195/2005 (Based on ITU-T K52-ICNIRP) 9 kHz to 300 GHz.Occupational and Public Exposure
2.- ELF – Reglamento Tecnico de Instalaciones Electricas –RETIE (Based on ICNIRP)
27/10/2008 ICNIRP 6TH 2008 22
EMF NATIONAL PROTECTION FRAMEWORK
Costa Rica: Resolución No 2896/98 - Power LinesLa Gazeta 248 22-12-98(Lower than ICNIRP)
27/10/2008 ICNIRP 6TH 2008 23
EMF NATIONAL PROTECTION FRAMEWORK
Ecuador:
Norma Técnica - Resolución CONATEL 01-01 2005 (Based on UIT K -52 and ICNIRP) 9 kHz to 300 GHz
27/10/2008 ICNIRP 6TH 2008 24
N° 01-01-CONATEL-2005EL CONSEJO NACIONAL DE
TELECOMUNICACIONES, CONATEL ECUADORConsiderando:
Que de conformidad con lo señalado en el artículo innumerado primero del artículo 10 de la Ley
Especial de Telecomunicaciones reformada, el Consejo Nacional de Telecomunicaciones es el organismo de administración y regulación de las telecomunicaciones en el país;
Que el artículo 247 de la Constitución Política de la República, así como el artículo 47 del Reglamento
General a . la Ley Especial de Telecomunicaciones reformada, disponen que el Espectro Radioeléctrico
es un recurso natural limitado, perteneciente al dominio público del Estado, en consecuencia es inalienable e imprescriptible;
Que la Organización Mundial de la Salud (OMS) mantiene el Proyecto Internacional CEM "Internacional
EMF PROYECT" sobre los efectos de los Campos Electromagnéticos (CEM) en la salud, y de cuyos
estudios hasta la fecha, no existen informes o datos comprobados de afectación, sin embargo con el
carácter de preventivo se han expedido en otros países normas y reglamentos de protección de
emisiones de radiación no ionizante;
Que la Unión Internacional de Telecomunicaciones expidió la Recomendación UIT-T K.52 "Orientación
sobre el cumplimiento de los límites de Exposición de las Personas a
Expedir el siguiente: REGLAMENTO DE PROTEC-CION DE EMISIONES DE RADIACION NO IONIZANTE GENERADAS POR USO DE FRECUENCIAS DEL ESPECTRO RADIOELECTRICO.
27/10/2008 ICNIRP 6TH 2008 25
EMF NATIONAL PROTECTION FRAMEWORK
México: NOM - 013/ STPS -1993 Only Occupational. Be updated 2008 (Based prob. on ICNIRP) 9 kHz e 300 GHz.
Comision Federal de Telecomunicaciones COFETEL PNN-2005 in progress NOM - 126
27/10/2008 ICNIRP 6TH 2008 26
EMF NATIONAL PROTECTION FRAMEWORK
Paraguay:
Ministry of Health and Social WelfareDecreto N 10071 – March 20070 Hz to 300 GHz (Based on ICNIRP Guidelines) Protocols based on ITU-T K.52
27/10/2008 ICNIRP 6TH 2008 27
EMF NATIONAL PROTECTION FRAMEWORK
Perú: Decreto Supremo MTC 038/2003 by INICTELUpdated by Decreto Supremo MTC 038/2006 (Based on ICNIRP) 9 kHz to 300 GHzResolucion Ministerial 120/05 MTCRestriction Areas (Hospitals and schools)0,1 mW/cm2 - 10 to 400MHz0,5 mW/cm2 - 2 to 300GHz
27/10/2008 ICNIRP 6TH 2008 28
EMF NATIONAL PROTECTION FRAMEWORK
Venezuela: Norma COVENIN NVC 2238-00-03 (Based on ICNIRP) 9 kHz to 300 GHz
Covers whole spectrumELF, RF and Optical Exposures
27/10/2008 ICNIRP 6TH 2008 29
EMF NATIONAL PROTECTION FRAMEWORK
Uruguay:
Unidad Reguladora de Servicios de Comunicaciones -URSEC with Ministry of Public Health from ROU Currently in process to establish NIR Regulations, based on ICNIRP Guidelines
27/10/2008 ICNIRP 6TH 2008 30
PUBLIC EXPOSURE VALUESU.S.A ANSI C95.1 - ARGENTINA-BRASIL-PERÚ - ITALY
PUBLIC EXPOSURE VALUESPUBLIC EXPOSURE VALUESU.S.A ANSI C95.1U.S.A ANSI C95.1 -- ARGENTINAARGENTINA--BRASILBRASIL--PERPERÚÚ -- ITALYITALY
** Blue line: coincidence
27/10/2008 ICNIRP 6TH 2008 31
Growing of Mobil Telephony in LA and WorldGrowing of Mobil Telephony in LA and World
27/10/2008 ICNIRP 6TH 2008 35
“Señalización RF Segura”
ZONA SEGURAZONA SEGURARADIACIÓN DE RF
TIEMPO DE PERMANENCIA
ILIMITADO
PROTECCIÓNRADIOSANITARIA – RF
Res. 202 / 95MINISTERIO DE SALUD
Y AMBIENTE
27/10/2008 ICNIRP 6TH 2008 36
POWER LINES - Argentina
Exposure Limits for E and B at 50Hz
POWER LINES - Argentina
Exposure Limits for E and B at 50Hz
ENRE 77/1998 E (kV/m):3 kV/m B (�T): 25 microTesla (250 mG) P/O
MTESS 295/03* E (kV/m):25 kV/m B (�T):1200 microTesla (12000 mG) O
ICNIRP/OMS **E (kV/m):10 kV/m B (�T):500 microTesla (5000 mG) OE (kV/m): 5 kV/m B (�T):100 microTesla (1000 mG) P
* Only Workers (Occupational)** ICNIRP/OMS- Recomendatións 1998*** P - Public, O - Occupational
ENRE 77/1998ENRE 77/1998 E (kV/m):3 kV/m B (E (kV/m):3 kV/m B (��T): 25 microTesla (250 mG) T): 25 microTesla (250 mG) P/OP/O
MTESS 295/03MTESS 295/03** E (kV/m):25 kV/m B (E (kV/m):25 kV/m B (��T):1200 microTesla (12000 mG) T):1200 microTesla (12000 mG) OO
ICNIRP/OMS ICNIRP/OMS ****E (kV/m):10 kV/m B (E (kV/m):10 kV/m B (��T):500 microTesla (5000 mG) T):500 microTesla (5000 mG) OOE (kV/m): 5 kV/m B (E (kV/m): 5 kV/m B (��T):100 microTesla (1000 mG) T):100 microTesla (1000 mG) PP
* Only Workers* Only Workers (Occupational)(Occupational)** ** ICNIRP/OMSICNIRP/OMS-- RecomendatiRecomendatióóns 1998ns 1998*** P *** P -- Public, O Public, O -- OccupationalOccupational
27/10/2008 ICNIRP 6TH 2008 37
Conclusions on EMF and Health Risks SSI Rapport from Sweden (2007)
Conclusions on EMF and Health Risks SSI Rapport from Sweden (2007)
27/10/2008 ICNIRP 6TH 2008 38
LASERS IN MEDICINE AND INDUSTRYFrequent use but NO Regulations
LASERS IN MEDICINE AND INDUSTRYFrequent use but NO Regulations
• Ultraviolet (UV – A B C )
• Visible
• Infrared (IR)
•• Ultraviolet (UV Ultraviolet (UV –– A B C ) A B C )
•• Visible Visible
•• Infrared (IR)Infrared (IR)
27/10/2008 ICNIRP 6TH 2008 39
UltravioletUltraviolet VisibleVisible InfraredInfrared
100 nm100 nm 400 nm400 nm 700 nm700 nm 100,000 nm100,000 nm
LASER SPECTRUMLASER SPECTRUMLASER SPECTRUM
ArgonArgon457457 -- 514 nm514 nm
DiodesDiodes805 805 -- 820 nm820 nm
Er:YAGEr:YAG2940 nm2940 nm
CO2CO2
Nd:YAGNd:YAG10641064 nmnm
10600 nm10600 nm
27/10/2008 ICNIRP 6TH 2008 40
Warning signal for LasersWarning signal for Lasers
LASER para TRATAMIENTO de PIELEVITE EXPOSICIÓN NO INTENCIONAL DIRECTA Y DISPERSA AL OJO Y PIEL
RADIACIÓN LASER INVISIBLE Potencia: 30 W - Clase IV
LASER SHARPLAN 20/C de CO2–10.600 nm (IR)MINISTERIO DE SALUD Y AMBIENTE - Radiofisica Sanitaria
27/10/2008 ICNIRP 6TH 2008 41
WHO
Defines Health as the state of complete physical, mental and social
well-being, and not merely the absence of
disease or infirmity
27/10/2008 ICNIRP 6TH 2008 42
CURRENT AVAILBLE INFORMATION
WEB: www.who.int/emf/
CURRENT AVAILBLE INFORMATIONCURRENT AVAILBLE INFORMATION
WEB: www.who.int/emf/WEB: www.who.int/emf/